Pipestem SP Wastewater System Improvements - Construction Plans.pdf

PDF 17 MB Posted

Attached to
Pipestem Resort Lodge New Wastewater Plant Construction
Solicitation number
CRFQ 0310 DNR2100000008 3
Issued by
Randolph County, West Virginia

About this file

This is a construction plans document for the Pipestem Resort State Park Wastewater System Improvements project located in Summers County, West Virginia, prepared by MOT MAC engineering firm. The project encompasses wastewater treatment upgrades at the McKeever Wastewater Treatment Plant (WWTP) and campground facilities. The scope of work includes demolition of existing treatment units and installation of a new Orenco FRP packaged wastewater treatment system consisting of textile filters in primary and tertiary stages. The project also includes grease trap replacement, yard piping improvements, erosion control measures, electrical upgrades, campsite dump station modifications with 35 sewer hook-up replacements, and miscellaneous site work. The construction plans contain 25 detailed sheets covering site layouts, process flow profiles, treatment tank and unit details, control building specifications, demolition phasing, storm drain profiles, cross-sections, erosion control plans, electrical schematics, and campground area improvements. The plans are dated November 2020 at 100% submittal stage, indicating the project was in final design phase.

The project includes phased demolition with Phase I to occur before new systems are operational and Phase II demolition after the new plant becomes operational. The existing treatment system must be disconnected and removed after new septic tanks are installed and operational by others. Permitting requirements from the West Virginia Department of Health and Human Resources are referenced, including approval for the new process and increased flows at the facility. The construction documents detail specific technical requirements for backfill and compaction, erosion control maintenance, fencing installation, storm drain specifications, manhole construction, and electrical connections. Design specifications address construction sequencing, material standards, quality control measures, temporary facilities, and safety protocols. The project represents a comprehensive modernization of aging wastewater infrastructure at a state park facility with coordination required between multiple construction phases and utility connections.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET

INDEX TO DRAWINGS

NAME

LOCATION MAP

NO SCALE

Title Sheet

N O

V E

M B

E R

General Layout

McKeever WWTP - Existing Conditions Site Plan

S U

M M

E R

S

C

O U

N T

Y

W

E S

T

V

I R

G I N

I A

McKeever WWTP - Proposed Site Plan04

McKeever WWTP - Process Flow Profile

McKeever WWTP - Treatment Tank Details

McKeever WWTP - Treatment Unit Details

McKeever WWTP - Control & Chemical Feed Building

McKeever WWTP - Demolition Plan - Phase I & Phase II

10 McKeever WWTP - Proposed Grease Trap Replacement & Access Road

McKeever WWTP - Proposed Yard Piping Plan

11 McKeever WWTP - Storm Drain Profiles

12 McKeever WWTP - Site Cross Sections

13 McKeever WWTP - Erosion Control Plan

14 McKeever WWTP - Erosion Control Notes and Details

15 McKeever WWTP - Erosion Control Details

16 McKeever WWTP - Miscellaneous Site Details

17 McKeever WWTP - Miscellaneous Site Details

18 McKeever WWTP - Electrical Site Plan

19 McKeever WWTP - Electrical Site Details

20 McKeever WWTP - Electrical Schematics & Schedules

21 Campground Area - Existing Dump Station Site Plan

22 Campground Area - Proposed Dump Station Site Plan

23 Campground Area - Dump Station Site Details

24 Campground Area - Miscellaneous Site Details

25 Campground Area - Dump Station Electrical Site & Details

RevStatus

Drawing Number

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\01-PIPESTEM GEN LAYOUT.dwg Nov 11, 2020 - 3:21PM GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

JJM

THS

THS

GDF

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal THSGDF

2 Nov. 2020 KDG 100% Submittal THSGDF

GRAPHIC SCALE

0' 500'

SITE MAP

DISCONNECT POWER & REMOVE EXISTING TREATMENT

UNIT AND ALL APPURTENANCES INCLUSIVE OF

SUBGRADE EQUIPMENT AFTER NEW SEPTIC TANKS

HAVE BEEN INSTALLED BY OTHERS AND ARE IN

OPERATION. SEE DEMOLITION SPECIFICATION FOR

DETAILED INSTRUCTIONS FOR REMOVAL AND

SALVAGING REQUIREMENTS.

C

P

E

Top=2552.6

C P

E

IE=2547.6

Top=2550.9

P

V

C

E

Top=2547.6

P

V C

Top=2553.9

IE=2542.3

1093-99

Inv =2548.1

Inv =2548.7

V

C

P

V

C P

V

C

P

CO.

CO.

SPLITTER

BOX

EXIST. TREATMENT UNIT #1

EXIST. TREATMENT UNIT #2

ELEC.

TRANS.

METER BASE

& DISCONNECT

HOSE BIBB

CONC. HEADWALL

PERMIT NO. WV 103110

OUTLET NO. 001

A

C

C

E

S

O

A

D

Inv =2547.8

E

X

I

S

T

O

N

Ex.MH

Ex.MH

RevStatus

Drawing Number

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\02-McKEEVER WWTP EXIST CONDITIONS.dwg Nov 11, 2020 -

3:31PM GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

JJM

THS

THS

GDF

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal THSGDF

2 Nov. 2020 KDG 100% Submittal THSGDF

GRAPHIC SCALE

0' 10'

SITE MAP

McKeever WWTP

Existing Conditions Site Plan

E

C P

E

IE=2547.6

Top=2550.9

P

V

C

E

Top=2547.6

P

V C

Top=2553.9

IE=2542.3

Inv =2548.1

V

C

P

V

C P

V

C

P

CO.

CO.

EXIST. TREATMENT UNIT #1

EXIST. TREATMENT UNIT #2

ELEC.

TRANS.

METER BASE

& DISCONNECT

CONC. HEADWALL

PERMIT NO. WV 103110

OUTLET NO. 001

E

X

I

S

O

A

C

E

A

D

Inv =2547.8

CUT & PLUG EXISTING

INLET LINE

CUT & PLUG EXISTING

OUTLET LINE

CAP EXISTING WATER LINE AND

REMOVE EXISTING YARD HYDRANT

DISCONNECT POWER & REMOVE

EXISTING TREATMENT UNIT #1 AND ALL

APPURTENANCES INCLUSIVE OF

SUBGRADE EQUIPMENT.

PLUG & ABANDON

EXISTING LINE

REMOVE EXISTING

SPLITTER BOX & BACKFILL

DISCONNECT POWER & REMOVE

EXISTING TREATMENT UNIT #2 AND ALL

APPURTENANCES.

REMOVE REMAINDER OF

EXIST. FENCE AND INSTALL

NEW FENCE AFTER SITE

WORK IS COMPLETE.

REMOVE EXISTING

MANHOLE & BACKFILL

PLUG OR REMOVE EXISTING

CULVERT PIPES AFTER NEW

STORM DRAINS ARE

INSTALLED.

RevStatus

Drawing Number

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\03-McKEEVER WWTP DEMO.dwg Nov 11, 2020 - 3:34PM GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

JJM

THS

THS

GDF

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal THSGDF

2 Nov. 2020 KDG 100% Submittal THSGDF

GRAPHIC SCALE

0' 10'

SITE MAP

McKeever WWTP

Demolition Plan - Phase I & Phase II

Legend

1 PHASE I DEMOLITION

2 PHASE II DEMOLITION

TO BE DONE AFTER NEW

PLANT IS IN OPERATION.

NOTE:

SEE DEMOLITION SPECIFICATION FOR DETAILED

INSTRUCTIONS FOR REMOVAL AND SALVAGING

REQUIREMENTS.

DEMOLITION AREAS TO BE

BACKFILLED TO MATCH

SURROUNDING GRADE

TO BE DONE AFTER NEW

PLANT IS IN OPERATION.

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\04-McKEEVER WWTP PROPOSED SITE.dwg Nov 12, 2020 - 1:51PM

GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

JJM

THS

THS

GDF

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal THSGDF

2 Nov. 2020 KDG 100% Submittal THSGDF

GRAPHIC SCALE

0' 10'

SITE MAP

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\05-McKEEVER WWTP YARD PIPING.dwg Nov 12, 2020 - 1:18PM

GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

JJM

THS

THS

GDF

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal THSGDF

2 Nov. 2020 KDG 100% Submittal THSGDF

GRAPHIC SCALE

0' 5'

YARD PIPING

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\06-McKEEVER WWTP HYD PROFILE.dwg Nov 11, 2020 - 3:57PM

GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

JJM

THS

THS

GDF

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal THSGDF

2 Nov. 2020 KDG 100% Submittal THSGDF

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\07-McKEEVER WWTP TANK DETAILS.dwg Nov 11, 2020 - 3:59PM

GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

JJM

THS

THS

GDF

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal THSGDF

2 Nov. 2020 KDG 100% Submittal THSGDF

McKeever WWTP

FOR BACKFILL AND COMPACTION SEE DETAIL 1

SHEET 08

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\08-McKEEVER WWTP UNIT DETAILS.dwg Nov 11, 2020 - 4:01PM

GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

JJM

THS

THS

GDF

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal THSGDF

2 Nov. 2020 KDG 100% Submittal THSGDF

McKeever WWTP

Lay a level, 95% compacted bed of <

" -in. (19-mm) aggregate, pea gravel, or approved granule for transfer lines.

Backfill in 12 -in. (300-mm) lifts - don't damage the lines.

Use a mechanical compacter to compact each lift.

If necessary, moisten the backfill material with water to help compaction.

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\09-McKEEVER WWTP CHEM BLDG.dwg Nov 12, 2020 - 1:04PM

GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

JJM

THS

THS

GDF

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal THSGDF

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\10-McKEEVER GREASE TRAP SITE.dwg Nov 11, 2020 - 4:07PM

GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

JJM

THS

THS

GDF

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal THSGDF

2 Nov. 2020 KDG 100% Submittal THSGDF

GRAPHIC SCALE

0' 20'

SITE MAP

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\11-McKEEVER WWTP STORM PROFILES.dwg Nov 11, 2020 - 4:10PM

GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

JJM

THS

THS

GDF

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal THSGDF

2 Nov. 2020 KDG 100% Submittal THSGDF

GRAPHIC SCALE

1"=10' HORIZ. & VERT.

PROFILES

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\12-McKEEVER WWTP SITE CROSS SECTIONS.dwg Nov 11, 2020 -

4:13PM GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

JJM

THS

THS

GDF

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal THSGDF

2 Nov. 2020 KDG 100% Submittal THSGDF

GRAPHIC SCALE

1"=10' HORIZ. & VERT.

CROSS SECTIONS

E

Top=2552.6

C P

E

IE=2547.6

Top=2550.9

P

V

C

E

Top=2547.6

P

V C

Top=2553.9

Top=2557.8

Top=2555.5

IE=2542.3

1093-99

1093-100

Inv =2549.8

Inv =2548.1

Inv =2548.7

V

C

P

V

C P

V

C

P

CO.

CO.

SPLITTER

BOX

EXIST. TREATMENT UNIT #1

EXIST. TREATMENT UNIT #2

ELEC.

TRANS.

METER BASE

& DISCONNECT

HOSE BIBB

CONC. HEADWALL

PERMIT NO. WV 103110

OUTLET NO. 001

A

C

C

E

A

D

M

P

Inv =2547.8

Inv =2542.7

E

X

I

S

O

Ex.MH

Ex.MH

Ex.MH

B-5

B-6

B-1

B-2

B-4

B-3

RevStatus

Drawing Number

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\13-McKEEVER WWTP S&E PLAN.dwg Nov 11, 2020 - 4:18PM

GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

JJM

THS

THS

GDF

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal THSGDF

2 Nov. 2020 KDG 100% Submittal THSGDF

GRAPHIC SCALE

0' 20'

SITE MAP

McKeever WWTP

NOTE:

ALL DISTURBED AREAS TO BE SEEDED & MULCHED AS

PER PARK AUTHORITIES DIRECTION.

10' MAX. C/C

M

I N

24" TO 36" LONG

2" X 2" HARDWOOD STAKES

SILTSOXX OR

APPROVED EQUAL

24" TO 36" LONG

2" X 2" HARDWOOD STAKES

SILTSOXX OR

APPROVED EQUAL

NOTE:

INLET AND DITCH CHECK MATERIAL SHALL BE SILTSOXX AS

MANUFACTURED BY FILTREXX INTERNATIONAL, OR ENGINEER'S

APPROVED EQUAL.

RevStatus

Drawing Number

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\13-McKEEVER WWTP S&E PLAN.dwg Nov 11, 2020 - 4:20PM

GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

JJM

THS

THS

GDF

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal THSGDF

MAINTENANCE NOTES:

1. INSPECT AFTER EACH 1/2" OF RAINFALL AND AT LEAST ONCE A WEEK AND REPAIRS MADE AS NEEDED.

2. SEDIMENT SHALL BE REMOVED AND THE TRAP RESTORED TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS

ACCUMULATED TO ONE HALF THE DESIGN DEPTH OF THE TRAP.

3. INLET PROTECTION SHOULD REMAIN IN PLACE AND OPERATIONAL UNTIL THE DRAINAGE AREA IS COMPLETELY STABILIZED.

M

A X

I M

U M

VARIES

M

I N

VARIES

VARIES

STONE CHECK DAM WITH OR WITHOUT SUMP MAINTENANCE

REQUIREMENTS

1. INSPECT EACH CHECK DAM AT A MINIMUM ONCE EVERY SEVEN

CALENDAR DAYS AND WITHIN 24 HOURS AFTER ANY STORM EVENT

GREATER THAN 0.5" OF RAIN PER 24 HOUR PERIOD. CHECK TO SEE

IF WATER HAS FLOWED AROUND THE EDGES OF THE STRUCTURE.

2. REPLACE STONE AND REPAIR DAMS AS NECESSARY TO MAINTAIN

CORRECT HEIGHT AND CONFIGURATION.

3. SEDIMENT SHOULD BE REMOVED FROM BEHIND THE CHECK

DAMS WHEN IT HAS ACCUMULATED TO ONE HALF OF THE ORIGINAL

HEIGHT OF THE DAM. DISPOSE OF THE SEDIMENT IN AN

APPROPRIATE PLACE.

4. DRAINAGE AREA OF 2 ACRES OR LESS USE AASHTO #1 STONE.

FOR DRAINAGE AREAS OF OVER 2 ACRES USE CLASS 1 RIPRAP.

A

C

I

N

G

SOIL TYPE AND SLOPE

SPACING DEPENDS ON THE

STEEPNESS

24" TO 36" LONG

1" X 1" HARDWOOD STAKES

WATTLES

F

L

O

W

SEDIMENT IS CAPTURED

BEHIND THE ROLLS

CONTOURS

FIBER ROLLS MUST BE PLACED

EXACTLY ON CONTOURS

ABUT ENDS FIRMLY

ALWAYS PLACE PERPENDICULAR

TO THE FLOW

MAINTENANCE NOTES:

1. INSPECT WATTLES AT LEAST ONCE A WEEK AND AFTER EACH RAIN EVENT GREATER THAN 0.5".

2. REPAIR OR REPLACE SPLIT,TORN,RAVELING, OR SLUMPING WATTLES.

3. REMOVE SEDIMENT ACCUMULATIONS WHEN EXCEEDING 1/2 THE HEIGHT BETWEEN THE TOP OF THE WATTLE AND THE

GROUND SURFACE.

4. REPAIR ANY RILLS OR GULLIES PROMPTLY. RESEED OR REPLANT VEGETATION IF NECESSARY UNTIL THE SLOPE IS

STABILIZED.

100' L.

100' L.

WEIR WIDTH

2' PLUS

2' PER ACRE

4' MAX

12" TYP.

COMPACTED EARTH BERM

FILTER FABRIC

VARIABLE

ORIGINAL GROUND

VARIABLE

DRY STORAGE

1800 CU. FT. / AC.

( EXCAVATED

1800 CU. FT. / AC.

WET STORAGE)

ORIGINAL GROUND

2" - 10" WELL-GRADED STONE

FILTER CLOTH

COARSE AGGREGATE 1' THICK

RIP RAP TRAP INLET PROTECTION

ELEVATION

CROSS SECTION

MAINTENANCE NOTES:

1. SEDIMENT SHOULD BE REMOVED FROM THE TRAP BEFORE THE TRAPS WET STORAGE VOLUME IS REDUCED BY

ONE-HALF. SEDIMENT REMOVED FROM THE TRAP SHOULD BE STORED OR DISPOSED IN A MANNER IN WHICH WILL NOT

CREATED AN EROSION OR SEDIMENT PROBLEM.

2. FILTER STONE SHOULD BE REGULARLY CHECKED TO ENSURE THAT FILTRATION PERFORMANCE IS MAINTAINED. STONE

CHOKED WITH SEDIMENT SHOULD BE REMOVED AND CLEANED OR REPLACED.

3. THE STRUCTURE SHALL BE CHECKED EVERY SEVEN DAYS AND/OR AFTER 0.5" OF RAIN TO ENSURE THAT IT IS

STRUCTURALLY SOUND AND HAS NOT DAMAGED.

VARIABLE

RevStatus

Drawing Number

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\13-McKEEVER WWTP S&E PLAN.dwg Nov 11, 2020 - 4:21PM

GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

JJM

THS

THS

GDF

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal THSGDF

12"

SUBSURFACE DRAIN DETAIL

V A

R I E

S

TYPICAL FENCE DETAILS

END POST

E N

D

P

O S

T

L E

N G

T H

C O

R N

S

T

L E

N G

T H

10'-0" MAX. SPACING

(3) STRANDS OF BARBED WIRE,

EACH CONSISTING OF 2 STRAND

LINE WIRE W/ 4 PT. BARBS.

LINE POST

45° B/W ARM

TENSION BAR

F

A B

R I

H

I G

H T

L I N

E

P

O S

T

L E

N G

T H

TRUSS ROD

ADJUSTING UNIT

" DIA. ADJUSTABLE

TRUSS ROD

TENSION BAND

12" O.C.

BRACE BAND

LINE POST TIE

12" O.C.

" O.D. BRACE

RAIL

BOTTOM SELVAGE

KNUCKLED

TENSION WIRE

7 GAUGE

HOG RING

18" O.C.

HOG RING

18" O.C.

DOME TOP

CORNER ARM

TENSION WIRE

7 GAUGE

CHAIN LINK FABRIC 2" MESH 6

GAUGE. TOP SELVAGE TWISTED

16" DIA. FOOTINGS

12'-0" OPENING

FACE TO FACE

TERMINAL / GATE POST

N

O M

H

E I G

H T

DOME TOP

BARBED WIRE

CHAIN LINK FABRIC 2" MESH 6

GAUGE.

" O.D. BRACE

RAIL

TENSION BAR

" O.D. FRAME

BOTTOM TENSION WIRE

TRUSS ROD

ADJUSTING UNIT

TRUSS ROD

DROP ROD

LATCH

HINGE

D E

P T

H

D E

P T

H

16" DIA. FOOTINGS

TRUSS ROD

ADJUSTING UNIT

3'-6"

2'-6"

"1

D

R O

P

CAST IRON FRAME & GRATE

3'-6"

6" 6"

PRECAST CONCRETE

DROP INLET

SEAL PIPE OPENING

W/ NON-SHRINK GROUT

(TYP.)

FLOW

18" HDPE PIPE

18" HDPE PIPE

18" HDPE PIPE

18" HDPE PIPE

DROP INLET DETAIL

NO SCALE

THE TOP OF THE INLET AND GRATE SHALL CONFORM

TO THE ELEVATION AND SLOPES OF THE PAVEMENT

UNLESS OTHER- WISE SHOWN ON THE PLANS OR

DIRECTED BY THE ENGINEER.

TYPICAL ACCESS ROAD SECTION

NO SCALE

1 1/2" AMERICAN

NATIONAL STRAIGHT

THREAD HOSE

CONNECTION

2" SCREWED BRASS 90° ELBOW

2" BRASS NIPPLE

YARD HYDRANT DETAIL

2" SERVICE

2"TYPE "K"

FITTING FLARED CONN.

x I.P. THREAD

M.J. PLUG

CONCRETE PADS

POST HYDRANT

NON-FREEZE

ZURN INDUSTRIES

CURB BOX

No. 1390

PAPER

TAR

2 CU. FT.

AASHTO 57

COPPER

2"CURB STOP

1/4" I.P.S.

DRAIN PORT

2" THK.

x I.P. THREAD

FITTING FLARED CONN.

2" SERVICE

RevStatus

Drawing Number

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\16-McKEEVER WWTP MISC.SITE DETAILS.dwg Nov 11, 2020 -

4:24PM GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

JJM

THS

THS

GDF

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal THSGDF

TYPICAL CONNECTION TO

EXISTING GRAVITY SEWER PIPE

SECTION

CONNECTION TO EXIST. MANHOLE DETAIL

EXTERIOR CASTING/CHIMNEY

SEAL INFI-SHIELD UNI-BAND

OR EQUAL

EXTERIOR JOINT WRAP

INFI-SHEILD GATOR WRAP

OR EQUAL

SECTIONAL PLAN

48" DIA. CONCRETE MANHOLE DETAIL

NOT TO SCALE

SECTION A-A

NOT TO SCALE

NOT TO SCALE

FILL ANNULAR SPACE WITH

NON-SHRINK GROUT

CONC. ENCASE AROUND

OPENING AND PIPE

2000 PSI CONCRETE

NEW SEWER LINE

NEOPRENE MANHOLE/PIPE

WATERSTOP WITH STAINLESS

STEEL HOSE CLAMP

RE-FORM CHANNEL

AS REQUIRED WITH

NON-SHRINK GROUT

AGGREGATE BEDDING

REPLACED PIPE SECTION

W/ STAINLESS STEEL SHEAR RING

FERNCO (OR EQUAL) COUPLING

EXISTING PIPE SECTION

AASHTO NO. 57

COARSE AGGREGATE

WHERE A TRANSITION MUST BE MADE TO THE PIPE FROM A PIPE

OF DIFFERENT MATERIAL AN APPROVED FLEXIBLE TYPE COUPLING OR

DONUT, COMPRESSION TYPE JOINT SEALER MUST BE UTILIZED. THE

COUPLINGS AND SEALERS MUST BE AS MANUFACTURED BY FERNCO

INC., OR APPROVED EQUAL..

WHERE THE EXISTING SEWER PIPE HAS BEEN BROKEN, THE PERIPHERY

SHALL BE CUT NEATLY IN A UNIFORM RADIUS PRIOR TO INSTALLATION

OF THE COUPLING/SEALER. JAGGED EDGES OF PIPE WILL NOT BE

PERMITTED.

3/4" DIA. S.S. ANCHOR BOLTS

(2 TYPICAL)

CASTING TO SIT ON

MASTIC BED "KENT SEAL"

OR EQUAL AND GROUT

1/2" COAT OF

CEMENT MORTAR

CONCRETE BRICK MASONRY

WATERPROOF OUTSIDE

OF MANHOLE WITH

THOROSEAL OR SIMILAR

MATERIAL

MASTIC JOINT MATERIAL

"KENT" SEAL OR EQUAL

TWO CONTINUOUS BEADS

MANHOLE STEPS POLYPROP.

PLASTIC COATED

(ASTM D-2146 TYPE II CR.49108)

3/8" GRADE 40 DEFORMED STL.

BAR (ASTM A-615)

48" DIA.

M

A X

29"

MIN. DIA.

CLEAR

27" DIA.

5"

PRECAST CONCRETE SECTIONS

(ASTM C-478)

NOTE: FORMED CHANNEL

DEPTH EQUAL TO

PIPE DIAMETER

MONOBASE

3000 PSI CONCRETE

6" THICK CRUSHED

STONE BEDDING

(AASHTO #57)

(SEE NOTE 1)

MIN.

8"

P I P

E

D I A

COVER TO BEAR THE WORDS

"CLB SANITARY SEWER"

EXCEPT AS NOTED, ALL MANHOLE FRAMES AND

COVERS SHALL BE EAST JORDAN OR EQUAL.

WATER TIGHT MANHOLES DESIGNATED AS

"W.T." ON THE DRAWINGS SHALL BE FURNISHED

W/ MACHINED GROOVE TO RECEIVE AN O RING SEAL.

OR APPROVED FLEXIBLE COUPLING

W/STAINLESS STL. STRAPS

FLEXIBLE BOOT

MANHOLE TO PIPE

PROVIDE MINIMUM 12" PVC

AND FERNCO FOR CONNECTION

TO EXISTING VCP

CHANNEL

FORMED

12"

MIN.

28 3/4"DIA.

V A

R I E

S

6"MAX.

OUTSIDE AS SHOWN

5"

12"

MAX

MIN

RIP-RAP

D =12"

D = 9"

D = 6"

24"

L

C

4'

TYPICAL RIP-RAP GUTTER DETAIL9

NO SCALE

CONCRETE CRADLE

END OF MAIN

SANITARY LINE

PIPE JOINTS AS

REQUIRED

2. CLEANOUT TO BE SAME

SIZE AS MAIN SANITARY

LINE

NOTES:

1. PIPE MUST NOT SUPPORT

INSPECTION FRAME AT

ANY POINT.

FRAME & LID

(NEENAH OR EQUAL)

PLUG

3'-0"

CAST IRON INSPECTION

CLEANOUT DETAIL

NOT TO SCALE

RIPRAP

GUTTER

8"

1'-4"

2'-0"

PLAN

SECTION

CONCRETE OUTFALL HEADWALL DETAIL

NO SCALE

4" PVC PLANT

EFFLUENT

4" PVC PLANT

EFFLUENT

#3 REBAR @ 12"

C/C, EACH WAY

RevStatus

Drawing Number

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\16-McKEEVER WWTP MISC.SITE DETAILS.dwg Nov 11, 2020 -

4:24PM GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

JJM

THS

THS

GDF

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal THSGDF

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\18-McKEEVER WWTP ELEC SITE.dwg Nov 23, 2020 - 3:45PM

GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

MNH

MNH

THS

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal MNH

2 Nov. 2020 KDG 100% Submittal MNH

IB

IB

IB

GRAPHIC SCALE

0' 5'

ELECTRICAL SITE PLAN

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\18-McKEEVER WWTP ELEC SITE.dwg Nov 23, 2020 - 3:46PM

GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

MNH

MNH

THS

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal MNH

2 Nov. 2020 KDG 100% Submittal MNH

IB

IB

IB

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\18-McKEEVER WWTP ELEC SITE.dwg Nov 23, 2020 - 3:47PM

GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

MNH

MNH

THS

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal MNH

2 Nov. 2020 KDG 100% Submittal MNH

IB

IB

IB

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\21-PIPESTEM CAMPGROUND SITE.dwg Nov 11, 2020 - 4:37PM

GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

JJM

THS

THS

GDF

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal THSGDF

2 Nov. 2020 KDG 100% Submittal THSGDF

GRAPHIC SCALE

0' 20'

SITE MAP

GENERAL NOTE

CONTRACTOR SHALL FIELD LOCATE AND VERIFY 35

CAMPSITE SEWER HOOK UP CONNECTIONS AND

REPLACE ALL WITH NEW CAMPSITE SEWER HOOK

UPS. SEE DETAIL 1 SHEET 24

NOTE:

UTILITY INFORMATION IS SHOWN HEREON FOR

INFORMATION ONLY AND IS INTENDED ONLY TO

INDICATE THE EXISTENCE THEREOF. IT IS BASED

ON EVIDENCE AVAILABLE AT THE TIME OF THE

SURVEY. THE UTILITY LOCATIONS AND INFORMATION

SHOWN MAY NOT BE ACCURATE OR COMPLETE

AND SHOULD NOT BE RELIED ON. ALL UTILITY

INFORMATION MUST BE VERIFIED IN THE FIELD

WITH THE APPROPRIATE AUTHORITIES PRIOR TO

ANY CONSTRUCTION OR OTHER USE.

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\22-PIPESTEM CAMPGROUND DUMP STATION SITE.dwg Nov 11, 2020 - 4:39PM GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

JJM

THS

THS

GDF

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal THSGDF

2 Nov. 2020 KDG 100% Submittal THSGDF

GRAPHIC SCALE

0' 5'

SITE MAP

NOTE:

UTILITY INFORMATION IS SHOWN HEREON FOR

INFORMATION ONLY AND IS INTENDED ONLY TO

INDICATE THE EXISTENCE THEREOF. IT IS BASED

ON EVIDENCE AVAILABLE AT THE TIME OF THE

SURVEY. THE UTILITY LOCATIONS AND INFORMATION

SHOWN MAY NOT BE ACCURATE OR COMPLETE

AND SHOULD NOT BE RELIED ON. ALL UTILITY

INFORMATION MUST BE VERIFIED IN THE FIELD

WITH THE APPROPRIATE AUTHORITIES PRIOR TO

ANY CONSTRUCTION OR OTHER USE.

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\22-PIPESTEM CAMPGROUND DUMP STATION SITE.dwg Nov 11, 2020 - 4:40PM GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

JJM

THS

THS

GDF

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal THSGDF

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\22-PIPESTEM CAMPGROUND DUMP STATION SITE.dwg Nov 11, 2020 - 4:41PM GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

JJM

THS

THS

GDF

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal THSGDF

Scale at ARCH D

Eng check

Approved

Coordination

Dwg check

Drawn

Designed

Title

Security

Client

App’dCh’k’dDescriptionDrawnDateRev

Project Number

TotalB/O

P:\WVDNR\403765 WVDNR Pipestem Wastewater\Pipestem Resort SP\DWG\25-PIPESTEM CAMPGROUND ELEC DET.dwg Nov 23, 2020 - 3:44PM

GAR69416

201 Pennsylvania Avenue, 4th Floor

Charleston, West Virginia 25302

U.S.A.

T 304.356.3010

F 304.357.9222

W www.motmac.com/americas

Pipestem Resort State Park

SUMMERS COUNTY, WEST VIRGINIA

507403765

As Noted PRE 2 STD

KDG

KDG

MNH

MNH

THS

Wastewater System Improvements

1 Sept. 2020 KDG 30% Submittal MNH

2 Nov. 2020 KDG 100% Submittal MNH

IB

IB

IB

GRAPHIC SCALE

0' 20'

ELECTRICAL SITE MAP

EXISTING BATHHOUSE

ELECTRICAL PANEL

W

G

N D

EXIST. LOAD

1 HP

NO SCALE

PARTIAL ONE LINE - BATHHOUSE POWER OPTION

P

V

H

EXISTING OFFICE

ELECTRICAL PANEL

EXIST. LOAD

1 HP

NO SCALE

PARTIAL ONE LINE - OFFICE POWER OPTION

NOTE:

UTILITY INFORMATION IS SHOWN HEREON FOR

INFORMATION ONLY AND IS INTENDED ONLY TO

INDICATE THE EXISTENCE THEREOF. IT IS BASED

ON EVIDENCE AVAILABLE AT THE TIME OF THE

SURVEY. THE UTILITY LOCATIONS AND INFORMATION

SHOWN MAY NOT BE ACCURATE OR COMPLETE

AND SHOULD NOT BE RELIED ON. ALL UTILITY

INFORMATION MUST BE VERIFIED IN THE FIELD

WITH THE APPROPRIATE AUTHORITIES PRIOR TO

ANY CONSTRUCTION OR OTHER USE.

20A / 2P

20A / 2P

W

G

N D

P

V

H

02_PIPESTEM_Engineer's Design Report
1. Background/Historical Info
2. Scope of Work
3. Existing McKeever Lodge Station Design
B. McKeever WWTP Effluent Limits and Flows
4. Proposed McKeever Lodge Station Design: An Orenco FRP Packaged WWTP is proposed to replace the aging and failing metal prefabricated units for the McKeever WWTP. The Orenco system is a system of prepackaged textile filters which consists of two distinct stages. A primary stage is expected to remove 50 percent of BOD from the process, and the tertiary stage (textile filters) will remove the remainder to below the prescribed effluent limits. The prepackaged Orenco system consists of the following:
5. McKeever Lodge Grease Trap Replacement
6. McKeever Lodge Proposed Civil Upgrades
A. Improve Vehicle Access at the Grease Trap
7. Campsite Dump station
8. Canyon Rim WWTP
9. Constructability Plan
A. McKeever WWTP
B. Grease Trap
The grease trap will be installed in the same time period as the new WWTP.
C. Canyon Rim Demolition
Demolition of the existing Canyon Rim WWTP must be coordinated with Pipestem to be performed after the installation of new septic systems (Separate contract)
10. Permitting and Planning Requirements
A. West Virginia Department of Health and Human Resources
The proposed upgrades to the WWTP includes new flow and a new process. The WV Bureau for Public Health representative was contacted to identify any permitting requirements. The representative advised that under the proposed conditions, the upgrades to the WWTP will require the following:
FRONT COVER - Pipestem
Pipestem WWTP 100% Submittal 11-12-20
00 01 10 Table of Contents
TABLE OF CONTENTS
AIA Document A101-2007
AIA General Conditions (003)
Division 01 Breaker
Pipestem Resort SP Wastewater Improvements 01 10 00 SUMMARY OF WORK 111120
SECTION 01 10 100
END OF SECTION
Pipestem Resort SP Wastewater Improvements 01 12 00 MATERIAL AND EQUIPMENT
PART 1 – GENERAL
PART 3 – EXECUTION
3.3 MATERIALS AND EQUIPMENT TO SUIT DESIGN
Pipestem Resort SP Wastewater Improvements 01 13 00 SPECIAL CONDITIONS
PART 1 – GENERAL
PART 2 – PRODUCTS (Not Used)
PART 3 – EXECUTION (Not Used)
Pipestem Resort SP Wastewater Improvements 01 29 00 MEASUREMENT AND PAYMENT
PART 1 – GENERAL
Pipestem Resort SP Wastewater Improvements 01 31 19 PROJECT MEETINGS
PROJECT MEETINGS
Pipestem Resort SP Wastewater Improvements 01 33 00 SUBMITTALS
Pipestem Resort SP Wastewater Improvements 01 45 00 QUALITY CONTROL
PART 2 – PRODUCTS (Not Used)
Pipestem Resort SP Wastewater Improvements 01 50 00 TEMPORARY FACILITIES
Division 02 Breaker
04_PIPESTEM_02 41 00 - DEMOLITION
PART 1 GENERAL
PART 2 PRODUCTS (NOT USED)
PART 3 EXECUTION
Division 13 Breaker
04_PIPESTEM_13 35 01 - FRP BUILDING
1.1 DESCIPTION
1.2 REFERENCE Specifications, codes and standards
1.3 warranty
1.4 SUBMITTALS
1.5 DELIVERY, STORAGE AND HANDLING
PART 2 PRODUCTS
PART 3 EXECUTION
Division 26 Breaker
Division 46 Breaker
04_46 25 24 DUMP STATION
PART 1 - GENERAL
PART 2 - STANDARDS
04_PIPESTEM_46 53 01 - AXMAX
PART 1 - GENERAL
PART 2 – PRODUCTS
PART 3 - EXECUTION
PIPESTEM 465301 - APPENDIX A
PAGE BLANK
FRONT COVER - Specs
PAGE BLANK
PAGE BLANK
PAGE BLANK
Pipestem Resort SP Wastewater Improvements 01 10 00 SUMMARY OF WORK 111120
Form_SJ ths
McKeever WL Allocation application
WLA Approval Ltr-electronic signature
WVG551164 Outlet 001-WLA for replacement of WWTP
00 01 10 Table of Contents
Electrical set
260500 - BASIC ELECTRICAL REQUIREMENTS_0
PART 1 - GENERAL
260519 Low-Voltage Electrical Power Conductors and Cables_0
1.1 RELATED DOCUMENTS
1.2 SUMMARY
1.3 ACTION SUBMITTALS
1.4 INFORMATIONAL SUBMITTALS
PART 2 - PRODUCTS
PART 3 - EXECUTION
260526 Grounding and Bonding_0
PART 1 - GENERAL
PART 2 - PRODUCTS
PART 3 - EXECUTION
260529 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS_0
PART 1 - GENERAL
PART 2 - PRODUCTS
PART 3 - EXECUTION
260533 Raceways and Boxes_0
PART 1 - GENERAL
PART 2 - PRODUCTS
PART 3 - EXECUTION
260553 Identification for Electrical Systems_0
PART 1 - GENERAL
PART 2 - PRODUCTS
PART 3 - EXECUTION
260573 OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY_0
PART 1 - GENERAL
PART 2 - PRODUCTS
PART 3 - EXECUTION
262813 Fuses_0
PART 1 - GENERAL
PART 2 - PRODUCTS
PART 3 - EXECUTION
262816 Enclosed Switches and Circuit Breakers_0
PART 1 - GENERAL
PART 2 - PRODUCTS
PART 3 - EXECUTION

PAGE BLANK

PAGE BLANK
PAGE BLANK
PAGE BLANK