These are mechanical HVAC drawings for the Phoenix Air Route Surveillance Radar (ARSR) facility and UPS building, prepared for the Federal Aviation Administration (FAA). The technical drawings show detailed mechanical plans for two separate buildings, featuring equipment room and UPS building HVAC layouts. The drawings include specifications for multiple HVAC components such as jet diffusers, return grills, disconnect switches, and ventilation equipment, with notations about airflow capacities (750 CFM and 1000 CFM). The documents are part of a solicitation (697DCK-25-R-00408) for an HVAC replacement project in Phoenix, Arizona, which involves removing existing HVAC units and installing two 15-ton packaged HVAC units, two V-PAC wall mounted systems, associated ductwork, and HVAC controls. The project is set aside for small businesses, with an estimated cost between $200,000-$400,000 and a projected performance period of approximately 60 calendar days.

View the file

Other files for this federal contract opportunity

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SA

44x16

RETURN GRILL

750CFM

D-4

1000CFM

D-1

1000CFM D-1

D-3

750CFM

D-2

RA

SA

RA

1000CFM

44/16

28/14

28/14 D-3 D-3

750CFM750CFM

$F

IL

ES

$D

AT

E$ $T

IM

E$

$N

AM

E$

A

B

C

D

E

F

G

H

8 7 6 5 4 3 2 1

H

G

F

E

D

C

12345678

REVDRAWING NO

DATE JCN

APPROVED BY

ISSUED BY

CHECKED

DRAWN

DESIGNED

SUBMITTED BY

REVIEWED BY

FEDERAL AVIATION ADMINISTRATION

DEPARTMENT OF TRANSPORTATION

REV APPROVED

DATE DESCRIPTION JCN REDLINE

DATE APVD

A

GENERAL NOTES:

MECHANICAL PLAN

SCALE: 1/4" = 1'

JET DIFFUSER

DIFFUSER-4 WAY

ROUTE CONDENSATE

OFF PAD

NEW DISCONNECTS

ROUTE CONDENSATE

OFF PAD

NEW CONCRETE

PAD

NEW CONCRETE

PAD

RETURN GRILL

(TYPICAL)

NEW EQUIPMENT:

4 84

SCALE: 1/4" = 1'

JET DIFFUSER

(TYPICAL 3 PLACES)

DIFFUSER-4 WAY (TYPICAL

2 PLACES)

TURNING VANE

(TYPICAL)

FLEXIBLE

CONNECTION

(TYPICAL)

TYPICAL DISCONNECT

NOT TO SCALE

DISCONNECT

SWITCH

ENSURE STAND

IS RIGID AND

STURDY

LOCKABLE

POINTS

AutoCAD SHX Text

CMU WALL

AutoCAD SHX Text

CMU WALL

AutoCAD SHX Text

CMU WALL

AutoCAD SHX Text

CMU WALL

AutoCAD SHX Text

%%UEQUIPMENT ROOM

AutoCAD SHX Text

WAVE GUIDE

AutoCAD SHX Text

ECONOMIZER HOOD

AutoCAD SHX Text

ECONOMIZER HOOD

AutoCAD SHX Text

ACU

AutoCAD SHX Text

AutoCAD SHX Text

ACU

AutoCAD SHX Text

AutoCAD SHX Text

%%UARSR TOWER

AutoCAD SHX Text

EDM:

AutoCAD SHX Text

ISSUED FOR:

AutoCAD SHX Text

QJB-D-ARSR-M001

AutoCAD SHX Text N/A

AutoCAD SHX Text 05/2025

AutoCAD SHX Text

MANAGER, AJW-B710

AutoCAD SHX Text

PROGRAM ANALYST, AJW-B710

AutoCAD SHX Text

HGB

AutoCAD SHX Text

HGB

AutoCAD SHX Text

HGB

AutoCAD SHX Text

HUNTER BITZER

AutoCAD SHX Text

JULIO CARRERAS

AutoCAD SHX Text

PHOENIX

AutoCAD SHX Text

AZ

AutoCAD SHX Text

EQUIPMENT ROOM HVAC

AutoCAD SHX Text

PHX ARSR

AutoCAD SHX Text

RESOURCE SERVICES

AutoCAD SHX Text

NDP

AutoCAD SHX Text

NAS DEFENSE PROGRAMS

AutoCAD SHX Text

RESOURCE SERVICES TEAM

AutoCAD SHX Text

CONTRACT DOCUMENT

AutoCAD SHX Text

1. CONTRACTOR SHALL FIELD VERIFY ALL ON-SITE MEASUREMENTS PRIOR TO FINAL CONTRACTOR SHALL FIELD VERIFY ALL ON-SITE MEASUREMENTS PRIOR TO FINAL FABRICATION. 2. REPLACE ALL FLUORESCENT LIGHTS THROUGHOUT THE FACILITY AS DETAILED IN THE SOW; REPLACE ALL FLUORESCENT LIGHTS THROUGHOUT THE FACILITY AS DETAILED IN THE SOW; EXTEND/REMOVE CIRCUITS AS REQUIRED. 3. CEILING TILES SHOULD BE REPLACED IN THEIR ENTIRETY. GRID MAY BE RETAINED FOR CEILING TILES SHOULD BE REPLACED IN THEIR ENTIRETY. GRID MAY BE RETAINED FOR CONTINUED USE WHERE APPLICABLE. 4. EXTERIOR DUCTWORK STRUCTURE SHALL BE REMOVED. EXTERIOR DUCTWORK STRUCTURE SHALL BE REMOVED. 5. EXTERIOR DUCTWORK SHALL BE REMOVED. EXTERIOR DUCTWORK SHALL BE REMOVED. 6. INTERIOR DUCTWORK STRUCTURE SHALL BE CLEANED AND RETAINED FOR CONTINUED USE INTERIOR DUCTWORK STRUCTURE SHALL BE CLEANED AND RETAINED FOR CONTINUED USE WHERE PRACTICAL. 7. INTERIOR DUCTWORK SHALL BE REMOVED. INTERIOR DUCTWORK SHALL BE REMOVED. 8. ALL NEW DISCONNECTS SHALL BE HEAVY DUTY, OUTDOOR RATED, LOCKABLE, AND SIZED ALL NEW DISCONNECTS SHALL BE HEAVY DUTY, OUTDOOR RATED, LOCKABLE, AND SIZED CORRECTLY FOR SERVICED EQUIPMENT. 9. DUCT DIMENSIONS SHOWN ARE INTERIOR (AIRWAY) DIMENSIONS. ALL DUCTWORK SHALL BE DUCT DIMENSIONS SHOWN ARE INTERIOR (AIRWAY) DIMENSIONS. ALL DUCTWORK SHALL BE EXTERNALLY INSULATED. ONCE FULLY SEALED/WEATHERPROOF, INSTALL 0.040 ALUMINUM SHEETING. 10. NEW HVAC UNITS SHALL BE GROUNDED TO COUNTERPOISE DIRECTLY OR BY MEANS OF NEW HVAC UNITS SHALL BE GROUNDED TO COUNTERPOISE DIRECTLY OR BY MEANS OF MULTIPOINT. RELOCATION OF EXISTING MULTI- POINT CAN BE PERFORMED TO ACCOMMODATE GROUNDING. 11. NEW HVAC UNITS SHALL HAVE A MIN 36" CLEARANCE AROUND ALL ACCESS DOORS AND NEW HVAC UNITS SHALL HAVE A MIN 36" CLEARANCE AROUND ALL ACCESS DOORS AND PANELS; MANUFACTURER MAY REQUIRE MORE. 12. RELOCATE INTERFERENCES AS-REQUIRED; ALL RELOCATIONS MUST BE APPROVED BY RELOCATE INTERFERENCES AS-REQUIRED; ALL RELOCATIONS MUST BE APPROVED BY ONSITE FAA REPRESENTATIVE. 13. INSTALL FURNISHED OAS CONTROLLER. INSTALL FURNISHED OAS CONTROLLER. 14. BALANCE DIFFUSERS TO AIRFLOW SPECIFIED +/- 10%. BALANCE DIFFUSERS TO AIRFLOW SPECIFIED +/- 10%.

AutoCAD SHX Text N

AutoCAD SHX Text 2 EA - PACKAGED HVAC UNITS - TRANE PRECEDENT (OR FAA APPROVED EQUIVALENT) FAA PROVIDED OAS HVAC CONTROLLER 2 EA - COUNTERWEIGHTED BACKDRAFT DAMPERS - RUSKIN CBD6 (OR FAA APPROVED EQUIVALENT) 2 EA - DUCT ACCESS DOORS - GREENHECK 14"X14" HAD TYPE

$F

IL

ES

$D

AT

E$ $T

IM

E$

$N

AM

E$

A

B

C

D

E

F

G

H

8 7 6 5 4 3 2 1

H

G

F

E

D

C

12345678

REVDRAWING NO

DATE JCN

APPROVED BY

ISSUED BY

CHECKED

DRAWN

DESIGNED

SUBMITTED BY

REVIEWED BY

FEDERAL AVIATION ADMINISTRATION

DEPARTMENT OF TRANSPORTATION

REV APPROVED

DATE DESCRIPTION JCN REDLINE

DATE APVD

A

SHEET NOTES:

LEGEND

UPS BUILDING MECHANICAL PLAN

SCALE: 1/2" = 1'

00 2 42

SCALE: 1/2" = 1'

AutoCAD SHX Text

%%UUPS BUILDING

AutoCAD SHX Text

EDM:

AutoCAD SHX Text

ISSUED FOR:

AutoCAD SHX Text

PHX-D-ARSR-M002

AutoCAD SHX Text N/A

AutoCAD SHX Text 05/2025

AutoCAD SHX Text

MANAGER, AJW-B710

AutoCAD SHX Text

PROGRAM ANALYST, AJW-B710

AutoCAD SHX Text

HGB

AutoCAD SHX Text

HGB

AutoCAD SHX Text

HGB

AutoCAD SHX Text

HUNTER BITZER

AutoCAD SHX Text

JULIO CARRERAS

AutoCAD SHX Text

PHOENIX

AutoCAD SHX Text

AZ

AutoCAD SHX Text

UPS BUILDING HVAC

AutoCAD SHX Text

PHX ARSR

AutoCAD SHX Text

RESOURCE SERVICES

AutoCAD SHX Text

NDP

AutoCAD SHX Text

NAS DEFENSE PROGRAMS

AutoCAD SHX Text

RESOURCE SERVICES TEAM

AutoCAD SHX Text

CONTRACT DOCUMENT

AutoCAD SHX Text

1. CONTRACTOR SHALL FIELD VERIFY ALL ON-SITE MEASUREMENTS PRIOR TO FINAL CONTRACTOR SHALL FIELD VERIFY ALL ON-SITE MEASUREMENTS PRIOR TO FINAL FABRICATION. 2. NEW HVAC UNITS SHALL BE GROUNDED TO COUNTERPOISE DIRECTLY OR BY MEANS OF NEW HVAC UNITS SHALL BE GROUNDED TO COUNTERPOISE DIRECTLY OR BY MEANS OF MULTIPOINT. RELOCATION OF EXISTING MULTI- POINT CAN BE PERFORMED TO ACCOMMODATE GROUNDING. 3. RELOCATE INTERFERENCES AS-REQUIRED; ALL RELOCATIONS MUST BE APPROVED BY RELOCATE INTERFERENCES AS-REQUIRED; ALL RELOCATIONS MUST BE APPROVED BY ONSITE FAA REPRESENTATIVE. 4. INSTALL FURNISHED OAS CONTROLLER. INSTALL FURNISHED OAS CONTROLLER.

AutoCAD SHX Text N

AutoCAD SHX Text 2 EA - VERTICAL PACKAGED HVAC UNITS - BARD (OR FAA APPROVED EQUIVALENT) FAA PROVIDED OAS HVAC CONTROLLER

PHX-D-ARSR-M001.pdf
Sheets and Views
M001
PHX-D-ARSR-M002.pdf
Sheets and Views
M002