Part 5 Reference Reports Wayne Oakland DCSpec_Rev_02-19.pdf

PDF 5 MB Posted

Attached to
761/20035. SAR Former Wayne Oakland Oil
Solicitation number
RFQ 171 200000000255 5
Issued by
Benzie County, Riverview City, Michigan

About this file

Summary

This document comprises laboratory analysis reports from the Michigan Department of Environmental Quality Environmental Laboratory related to environmental testing conducted at the Wayne Oakland Oil site (Project No. 3940096) located in Royal Oak, Michigan. The testing involved groundwater and soil samples collected between March and December 2009 to assess contamination from petroleum products. The laboratory performed comprehensive chemical analysis including volatile organic compounds (VOCs), semi-volatile organic compounds (SVOCs), pesticides, PCBs, and heavy metals testing using EPA-approved analytical methods including Methods 8260, 8270, 8082, and various inorganic digestion methods. Multiple sample types were analyzed, including monitoring well water samples, soil boring samples, and quality control samples (trip blanks, field blanks, equipment blanks, and matrix spike/matrix spike duplicate samples).

The laboratory reports document analysis of approximately 78 water samples and 16 soil samples with total charges of $8,209.00 for water testing (Work Order #90400113) and $8,261.00 for additional water testing, along with separate sediment analysis charges of $804.50 and $2,589.50. Results indicated presence of petroleum-related compounds including naphthalene, methylnaphthalene, benzene, and other aromatic hydrocarbons in groundwater at depths between 5 and 11.5 feet below grade. Lead concentrations in certain soil samples exceeded background levels (ranging up to 1,700 micrograms per kilogram), while most volatile and semi-volatile organic analytes and pesticides were non-detected. The completion dates ranged from June 3 through January 14, 2010, with samples collected by Mike Brennan of the MDEQ-RRD Warren Southeast Michigan District Office.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1.00 1.50

2.50

9.00

11.00

647.51 647.01

646.01

639.51

637.51

Concrete

Natural Collapse

Bentonite Chips

Filter Pack Sand

PVC Screen

Natural Collapse

D E

P T

H (f t.)

CONSTRUCTION

REMARKS

E

LE

V A

T

IO

N (f t.)

WELL

DETAILS

S Y

M B

O L

D E

P T

H (f t.)WELL CONSTRUCTION DETAILS V A

S

STRATA

0.0

WATER LEVEL:

DATE:

TIME:

Wayne Oakland Oil 3940096 Royal Oak, MI

SEAL

DRILLING CONTRACTOR:

DRILLING METHOD:

DATE COMPLETED:

0.000.49'

Type:

Interval:

None None

GS

SANDPACK

Diameter:

Type:

Interval:

Diameter:

Type:

Interval:

648.5

USGS

M. Brennan

8" Steel 0 ft above grade to 1 ft below grade

SCREEN

PROJECT:

PROJECT NO:

PROJECT LOCATION:

GROUND SURFACE ELEVATION:

DATUM:

LOGGED BY:

Sand Filter Pack 2.5-9 ft below grade

Sheet 1 of 1COMPLETION REPORT OF WELL No. MW-1 / SB-14

TRC

2"

PVC

0.49 - 4 ft below grade

Type:

Interval:

PROTECTIVE CASING

648.51

Type:

Interval:

WELL DEVELOPMENT DATA

DATE:

METHOD:

7/29/2009

Overpumping with occasional surging.

Diameter:

Type:

Interval:

2"

PVC

4-9 ft below grade

Bentonite Chips

1.5 - 2.5 ft below grade

Terra Probe

Direct Push

7/29/2009

GROUT

RISER CASING

5.00 7/29/09

CONCRETE

CEMENT/BENTONITE GROUT

FILTER PACK

BENTONITE

BENTONITE/NATURAL COLLAPSE

FILL

SAND

SILT

CLAY

GRAVELLY CLAY

ASPHALT

TOPSOIL

INTERBEDDED SAND, SILT, CLAY

COMPLETION REPORT OF

WELL No. MW-1 / SB-14

Sheet 1 of 1

TPC

TRC

GS

TOP OF PROTECTIVE CASING

TOP OF RISER CASING

GROUND SURFACE

LEGEND

101 South Washington Square, Suite 400 Lansing, MI 48933 Telephone: (517) 337-0111 Fax: (517) 337-0417

3.00

9.00

648.03

646.03

640.03

Concrete

Natural Collapse

Bentonite Chips

Filter Pack Sand

PVC Screen

D E

P T

H (f t.)

CONSTRUCTION

REMARKS

E

LE

V A

T

IO

N (f t.)

WELL

DETAILS

S Y

M B

O L

D E

P T

H (f t.)WELL CONSTRUCTION DETAILS V A

S

STRATA

0.0

WATER LEVEL:

DATE:

TIME:

Wayne Oakland Oil 3940096 Royal Oak, MI

SEAL

DRILLING CONTRACTOR:

DRILLING METHOD:

DATE COMPLETED:

0.000.61'

Type:

Interval:

None None

GS

SANDPACK

Diameter:

Type:

Interval:

Diameter:

Type:

Interval:

649.0

USGS

M. Brennan

8" Steel 0 ft above grade to 1 ft below grade

SCREEN

PROJECT:

PROJECT NO:

PROJECT LOCATION:

GROUND SURFACE ELEVATION:

DATUM:

LOGGED BY:

Sand Filter Pack 3-9 ft below grade

Sheet 1 of 1COMPLETION REPORT OF WELL No. MW-2

TRC

2"

PVC

0.61 - 4 ft below grade

Type:

Interval:

PROTECTIVE CASING

649.03

Type:

Interval:

WELL DEVELOPMENT DATA

DATE:

METHOD:

7/29/2009

Overpumping with occasional surging.

Diameter:

Type:

Interval:

2"

PVC

4-9 ft below grade

Bentonite Chips 1 - 3 ft below grade

Terra Probe

4.25" HSA

7/29/2009

GROUT

RISER CASING

5.00

CONCRETE

CEMENT/BENTONITE GROUT

FILTER PACK

BENTONITE

BENTONITE/NATURAL COLLAPSE

FILL

SAND

SILT

CLAY

GRAVELLY CLAY

ASPHALT

TOPSOIL

INTERBEDDED SAND, SILT, CLAY

COMPLETION REPORT OF

WELL No. MW-2

Sheet 1 of 1

TPC

TRC

GS

TOP OF PROTECTIVE CASING

TOP OF RISER CASING

GROUND SURFACE

LEGEND

101 South Washington Square, Suite 400 Lansing, MI 48933

3.00

9.00

647.66

645.66

639.66

Concrete

Natural Collapse

Bentonite Chips

Filter Pack Sand

PVC Screen

D E

P T

H (f t.)

CONSTRUCTION

REMARKS

E

LE

V A

T

IO

N (f t.)

WELL

DETAILS

S Y

M B

O L

D E

P T

H (f t.)WELL CONSTRUCTION DETAILS V A

S

STRATA

0.0

WATER LEVEL:

DATE:

TIME:

Wayne Oakland Oil 3940096 Royal Oak, MI

SEAL

DRILLING CONTRACTOR:

DRILLING METHOD:

DATE COMPLETED:

0.000.52'

Type:

Interval:

None None

GS

SANDPACK

Diameter:

Type:

Interval:

Diameter:

Type:

Interval:

648.7

USGS

M. Brennan

8" Steel 0 ft above grade to 1 ft below grade

SCREEN

PROJECT:

PROJECT NO:

PROJECT LOCATION:

GROUND SURFACE ELEVATION:

DATUM:

LOGGED BY:

Sand Filter Pack 3-9 ft below grade

Sheet 1 of 1COMPLETION REPORT OF WELL No. MW-3

TRC

2"

PVC

0.52 - 4 ft below grade

Type:

Interval:

PROTECTIVE CASING

648.66

Type:

Interval:

WELL DEVELOPMENT DATA

DATE:

METHOD:

7/29/2009

Overpumping with occasional surging.

Diameter:

Type:

Interval:

2"

PVC

4-9 ft below grade

Bentonite Chips 1 - 3 ft below grade

Terra Probe

4.25" HSA

7/29/2009

GROUT

RISER CASING

5.00

CONCRETE

CEMENT/BENTONITE GROUT

FILTER PACK

BENTONITE

BENTONITE/NATURAL COLLAPSE

FILL

SAND

SILT

CLAY

GRAVELLY CLAY

ASPHALT

TOPSOIL

INTERBEDDED SAND, SILT, CLAY

COMPLETION REPORT OF

WELL No. MW-3

Sheet 1 of 1

TPC

TRC

GS

TOP OF PROTECTIVE CASING

TOP OF RISER CASING

GROUND SURFACE

LEGEND

101 South Washington Square, Suite 400 Lansing, MI 48933

3.50

9.50

12.00

647.59

645.09

639.09

636.59

Concrete

Natural Collapse

Bentonite Chips

Filter Pack Sand

PVC Screen

D E

P T

H (f t.)

CONSTRUCTION

REMARKS

E

LE

V A

T

IO

N (f t.)

WELL

DETAILS

S Y

M B

O L

D E

P T

H (f t.)WELL CONSTRUCTION DETAILS V A

S

STRATA

0.0

WATER LEVEL:

DATE:

TIME:

Wayne Oakland Oil 3940096 Royal Oak, MI

SEAL

DRILLING CONTRACTOR:

DRILLING METHOD:

DATE COMPLETED:

0.000.29'

Type:

Interval:

None None

GS

SANDPACK

Diameter:

Type:

Interval:

Diameter:

Type:

Interval:

648.6

USGS

M. Brennan

8" Steel 0 ft above grade to 1 ft below grade

SCREEN

PROJECT:

PROJECT NO:

PROJECT LOCATION:

GROUND SURFACE ELEVATION:

DATUM:

LOGGED BY:

Sand Filter Pack 3.5-12 ft below grade

Sheet 1 of 1COMPLETION REPORT OF WELL No. MW-4 / SB-MW-4

TRC

2"

PVC

0.29 - 4 ft below grade

Type:

Interval:

PROTECTIVE CASING

648.59

Type:

Interval:

WELL DEVELOPMENT DATA

DATE:

METHOD:

11/11/2009

Overpumping with occasional surging.

Diameter:

Type:

Interval:

2"

PVC

4.5-9.5 ft below grade

Bentonite Chips 1 - 3.5 ft below grade

Terra Probe

Direct Push / HSA

11/10/2009

GROUT

RISER CASING

6.00 11/10/09

CONCRETE

CEMENT/BENTONITE GROUT

FILTER PACK

BENTONITE

BENTONITE/NATURAL COLLAPSE

FILL

SAND

SILT

CLAY

GRAVELLY CLAY

ASPHALT

TOPSOIL

INTERBEDDED SAND, SILT, CLAY

COMPLETION REPORT OF

WELL No. MW-4 / SB-MW-4

Sheet 1 of 1

TPC

TRC

GS

TOP OF PROTECTIVE CASING

TOP OF RISER CASING

GROUND SURFACE

LEGEND

101 South Washington Square, Suite 400 Lansing, MI 48933

4.00

10.30

12.00

646.58

643.58

637.28

635.58

Concrete

Natural Collapse

Bentonite Chips

Filter Pack Sand

PVC Screen

Natural Collapse

D E

P T

H (f t.)

CONSTRUCTION

REMARKS

E

LE

V A

T

IO

N (f t.)

WELL

DETAILS

S Y

M B

O L

D E

P T

H (f t.)WELL CONSTRUCTION DETAILS V A

S

STRATA

0.0

WATER LEVEL:

DATE:

TIME:

Wayne Oakland Oil 3940096 Royal Oak, MI

SEAL

DRILLING CONTRACTOR:

DRILLING METHOD:

DATE COMPLETED:

0.000.39'

Type:

Interval:

None None

GS

SANDPACK

Diameter:

Type:

Interval:

Diameter:

Type:

Interval:

647.6

USGS

M. Brennan

8" Steel 0 ft above grade to 1 ft below grade

SCREEN

PROJECT:

PROJECT NO:

PROJECT LOCATION:

GROUND SURFACE ELEVATION:

DATUM:

LOGGED BY:

Sand Filter Pack 4-10.3 ft below grade

Sheet 1 of 1COMPLETION REPORT OF WELL No. MW-5 / SB-MW-5

TRC

2"

PVC

0.39 - 5.3 ft below grade

Type:

Interval:

PROTECTIVE CASING

647.58

Type:

Interval:

WELL DEVELOPMENT DATA

DATE:

METHOD:

11/10/2009

Overpumping with occasional surging.

Diameter:

Type:

Interval:

2"

PVC

5.3-10.3 ft below grade

Bentonite Chips 1 - 4 ft below grade

Terra Probe

Direct Push / HSA

11/10/2009

GROUT

RISER CASING

6.50 11/10/09

CONCRETE

CEMENT/BENTONITE GROUT

FILTER PACK

BENTONITE

BENTONITE/NATURAL COLLAPSE

FILL

SAND

SILT

CLAY

GRAVELLY CLAY

ASPHALT

TOPSOIL

INTERBEDDED SAND, SILT, CLAY

COMPLETION REPORT OF

WELL No. MW-5 / SB-MW-5

Sheet 1 of 1

TPC

TRC

GS

TOP OF PROTECTIVE CASING

TOP OF RISER CASING

GROUND SURFACE

LEGEND

101 South Washington Square, Suite 400 Lansing, MI 48933

9.20

12.00

647.48

644.98

639.28

636.48

Concrete

Natural Collapse

Bentonite Chips

Filter Pack Sand

PVC Screen

D E

P T

H (f t.)

CONSTRUCTION

REMARKS

E

LE

V A

T

IO

N (f t.)

WELL

DETAILS

S Y

M B

O L

D E

P T

H (f t.)WELL CONSTRUCTION DETAILS V A

S

STRATA

0.0

WATER LEVEL:

DATE:

TIME:

Wayne Oakland Oil 3940096 Royal Oak, MI

SEAL

DRILLING CONTRACTOR:

DRILLING METHOD:

DATE COMPLETED:

0.000.44'

Type:

Interval:

None None

GS

SANDPACK

Diameter:

Type:

Interval:

Diameter:

Type:

Interval:

648.5

USGS

M. Brennan

8" Steel 0 ft above grade to 1 ft below grade

SCREEN

PROJECT:

PROJECT NO:

PROJECT LOCATION:

GROUND SURFACE ELEVATION:

DATUM:

LOGGED BY:

Sand Filter Pack 3.5-12 ft below grade

Sheet 1 of 1COMPLETION REPORT OF WELL No. MW-6 / SB-MW-6

TRC

2"

PVC

0.44 - 4.2 ft below grade

Type:

Interval:

PROTECTIVE CASING

648.48

Type:

Interval:

WELL DEVELOPMENT DATA

DATE:

METHOD:

NA

NA

Diameter:

Type:

Interval:

2"

PVC

4.2-9.2 ft below grade

Bentonite Chips 1 - 3.5 ft below grade

Terra Probe

Direct Push / HSA

11/10/2009

GROUT

RISER CASING

6.50 11/10/09

CONCRETE

CEMENT/BENTONITE GROUT

FILTER PACK

BENTONITE

BENTONITE/NATURAL COLLAPSE

FILL

SAND

SILT

CLAY

GRAVELLY CLAY

ASPHALT

TOPSOIL

INTERBEDDED SAND, SILT, CLAY

COMPLETION REPORT OF

WELL No. MW-6 / SB-MW-6

Sheet 1 of 1

TPC

TRC

GS

TOP OF PROTECTIVE CASING

TOP OF RISER CASING

GROUND SURFACE

LEGEND

101 South Washington Square, Suite 400 Lansing, MI 48933

5.50

11.00

12.00

647.42

642.92

637.42

636.42

Concrete

Natural Collapse

Bentonite Chips

Filter Pack Sand PVC Screen

D E

P T

H (f t.)

CONSTRUCTION

REMARKS

E

LE

V A

T

IO

N (f t.)

WELL

DETAILS

S Y

M B

O L

D E

P T

H (f t.)WELL CONSTRUCTION DETAILS V A

S

STRATA

0.0

WATER LEVEL:

DATE:

TIME:

Wayne Oakland Oil 3940096 Royal Oak, MI

SEAL

DRILLING CONTRACTOR:

DRILLING METHOD:

DATE COMPLETED:

0.000.37'

Type:

Interval:

None None

GS

SANDPACK

Diameter:

Type:

Interval:

Diameter:

Type:

Interval:

648.4

USGS

M. Brennan

8" Steel 0 ft above grade to 1 ft below grade

SCREEN

PROJECT:

PROJECT NO:

PROJECT LOCATION:

GROUND SURFACE ELEVATION:

DATUM:

LOGGED BY:

Sand Filter Pack 5.5-12 ft below grade

Sheet 1 of 1COMPLETION REPORT OF WELL No. MW-7 / SB-MW-7

TRC

2"

PVC

0.37 - 4.2 ft below grade

Type:

Interval:

PROTECTIVE CASING

648.42

Type:

Interval:

WELL DEVELOPMENT DATA

DATE:

METHOD:

7/29/2010

Overpumping with occasional surging.

Diameter:

Type:

Interval:

2"

PVC

6-11 ft below grade

Bentonite Chips 1 - 5.5 ft below grade

Terra Probe

Direct Push / HSA

7/28/2010

GROUT

RISER CASING

7.00 7/28/10

CONCRETE

CEMENT/BENTONITE GROUT

FILTER PACK

BENTONITE

BENTONITE/NATURAL COLLAPSE

FILL

SAND

SILT

CLAY

GRAVELLY CLAY

ASPHALT

TOPSOIL

INTERBEDDED SAND, SILT, CLAY

COMPLETION REPORT OF

WELL No. MW-7 / SB-MW-7

Sheet 1 of 1

TPC

TRC

GS

TOP OF PROTECTIVE CASING

TOP OF RISER CASING

GROUND SURFACE

LEGEND

101 South Washington Square, Suite 400 Lansing, MI 48933

2.50

3.50

6.00

647.10

645.60

644.60

642.10

Concrete

Bentonite Chips

Filter Pack Sand Stainless Steel Implant

D E

P T

H (f t.)

CONSTRUCTION

REMARKS

E

LE

V A

T

IO

N (f t.)

WELL

DETAILS

S Y

M B

O L

D E

P T

H (f t.)WELL CONSTRUCTION DETAILS V A

S

STRATA

0.0

WATER LEVEL:

DATE:

TIME:

Wayne Oakland Oil 3940096 Royal Oak, MI

SEAL

DRILLING CONTRACTOR:

DRILLING METHOD:

DATE COMPLETED:

0.00NA

Type:

Interval:

None None

GS

SANDPACK

Diameter:

Type:

Interval:

Diameter:

Type:

Interval:

648.1

USGS

M. Brennan

7" Steel 0 ft above grade to 1 ft below grade

SCREEN

PROJECT:

PROJECT NO:

PROJECT LOCATION:

GROUND SURFACE ELEVATION:

DATUM:

LOGGED BY:

Sand Filter Pack 2.5-6 ft below grade

Sheet 1 of 1COMPLETION REPORT OF WELL No. SB-SGW-1

TRC

0.25" OD (0.17" ID)

Nylon Tubing 0 - 3.0 ft below grade

Type:

Interval:

PROTECTIVE CASING

648.10

Type:

Interval:

WELL DEVELOPMENT DATA

DATE:

METHOD:

NA

NA

Diameter:

Type:

Interval:

0.5" ID

Stainless Steel Implant 3-3.5 ft below grade

Bentonite Chips 1 - 2.5 ft below grade

Terra Probe

Direct Push

7/28/2010

GROUT

RISER CASING

4.50 7/28/10

CONCRETE

CEMENT/BENTONITE GROUT

FILTER PACK

BENTONITE

BENTONITE/NATURAL COLLAPSE

FILL

SAND

SILT

CLAY

GRAVELLY CLAY

ASPHALT

TOPSOIL

INTERBEDDED SAND, SILT, CLAY

COMPLETION REPORT OF

WELL No. SB-SGW-1

Sheet 1 of 1

TPC

TRC

GS

TOP OF PROTECTIVE CASING

TOP OF RISER CASING

GROUND SURFACE

LEGEND

101 South Washington Square, Suite 400 Lansing, MI 48933

2.50

3.50

6.00

647.10

645.60

644.60

642.10

Concrete

Bentonite Chips

Filter Pack Sand Stainless Steel Implant

D E

P T

H (f t.)

CONSTRUCTION

REMARKS

E

LE

V A

T

IO

N (f t.)

WELL

DETAILS

S Y

M B

O L

D E

P T

H (f t.)WELL CONSTRUCTION DETAILS V A

S

STRATA

0.0

WATER LEVEL:

DATE:

TIME:

Wayne Oakland Oil 3940096 Royal Oak, MI

SEAL

DRILLING CONTRACTOR:

DRILLING METHOD:

DATE COMPLETED:

0.00NA

Type:

Interval:

None None

GS

SANDPACK

Diameter:

Type:

Interval:

Diameter:

Type:

Interval:

648.1

USGS

M. Brennan

7" Steel 0 ft above grade to 1 ft below grade

SCREEN

PROJECT:

PROJECT NO:

PROJECT LOCATION:

GROUND SURFACE ELEVATION:

DATUM:

LOGGED BY:

Sand Filter Pack 2.5-6 ft below grade

Sheet 1 of 1COMPLETION REPORT OF WELL No. SB-SGW-2

TRC

0.25" OD (0.17" ID)

Nylon Tubing 0 - 3.0 ft below grade

Type:

Interval:

PROTECTIVE CASING

648.10

Type:

Interval:

WELL DEVELOPMENT DATA

DATE:

METHOD:

NA

NA

Diameter:

Type:

Interval:

0.5" ID

Stainless Steel Implant 3-3.5 ft below grade

Bentonite Chips 1 - 2.5 ft below grade

Terra Probe

Direct Push

7/28/2010

GROUT

RISER CASING

4.50 7/28/10

CONCRETE

CEMENT/BENTONITE GROUT

FILTER PACK

BENTONITE

BENTONITE/NATURAL COLLAPSE

FILL

SAND

SILT

CLAY

GRAVELLY CLAY

ASPHALT

TOPSOIL

INTERBEDDED SAND, SILT, CLAY

COMPLETION REPORT OF

WELL No. SB-SGW-2

Sheet 1 of 1

TPC

TRC

GS

TOP OF PROTECTIVE CASING

TOP OF RISER CASING

GROUND SURFACE

LEGEND

101 South Washington Square, Suite 400 Lansing, MI 48933

5.00

7.00

648.40

645.40

644.40

642.40

Concrete

Bentonite Chips

Filter Pack Sand Stainless Steel Implant

D E

P T

H (f t.)

CONSTRUCTION

REMARKS

E

LE

V A

T

IO

N (f t.)

WELL

DETAILS

S Y

M B

O L

D E

P T

H (f t.)WELL CONSTRUCTION DETAILS V A

S

STRATA

0.0

WATER LEVEL:

DATE:

TIME:

Wayne Oakland Oil 3940096 Royal Oak, MI

SEAL

DRILLING CONTRACTOR:

DRILLING METHOD:

DATE COMPLETED:

0.00NA

Type:

Interval:

None None

GS

SANDPACK

Diameter:

Type:

Interval:

Diameter:

Type:

Interval:

649.4

USGS

M. Brennan

7" Steel 0 ft above grade to 1 ft below grade

SCREEN

PROJECT:

PROJECT NO:

PROJECT LOCATION:

GROUND SURFACE ELEVATION:

DATUM:

LOGGED BY:

Sand Filter Pack 4-7 ft below grade

Sheet 1 of 1COMPLETION REPORT OF WELL No. SB-SGW-3

TRC

0.25" OD (0.17" ID)

Nylon Tubing 0 - 4.5 ft below grade

Type:

Interval:

PROTECTIVE CASING

649.40

Type:

Interval:

WELL DEVELOPMENT DATA

DATE:

METHOD:

NA

NA

Diameter:

Type:

Interval:

0.5" ID

Stainless Steel Implant 4.5-5 ft below grade

Bentonite Chips 1 - 4 ft below grade

Terra Probe

Direct Push

7/28/2010

GROUT

RISER CASING

6.00 7/28/10

CONCRETE

CEMENT/BENTONITE GROUT

FILTER PACK

BENTONITE

BENTONITE/NATURAL COLLAPSE

FILL

SAND

SILT

CLAY

GRAVELLY CLAY

ASPHALT

TOPSOIL

INTERBEDDED SAND, SILT, CLAY

COMPLETION REPORT OF

WELL No. SB-SGW-3

Sheet 1 of 1

TPC

TRC

GS

TOP OF PROTECTIVE CASING

TOP OF RISER CASING

GROUND SURFACE

LEGEND

101 South Washington Square, Suite 400 Lansing, MI 48933

5.00

6.00

647.40

644.40

643.40

642.40

Concrete

Bentonite Chips

Filter Pack Sand Stainless Steel Implant

D E

P T

H (f t.)

CONSTRUCTION

REMARKS

E

LE

V A

T

IO

N (f t.)

WELL

DETAILS

S Y

M B

O L

D E

P T

H (f t.)WELL CONSTRUCTION DETAILS V A

S

STRATA

0.0

WATER LEVEL:

DATE:

TIME:

Wayne Oakland Oil 3940096 Royal Oak, MI

SEAL

DRILLING CONTRACTOR:

DRILLING METHOD:

DATE COMPLETED:

0.00NA

Type:

Interval:

None None

GS

SANDPACK

Diameter:

Type:

Interval:

Diameter:

Type:

Interval:

648.4

USGS

M. Brennan

7" Steel 0 ft above grade to 1 ft below grade

SCREEN

PROJECT:

PROJECT NO:

PROJECT LOCATION:

GROUND SURFACE ELEVATION:

DATUM:

LOGGED BY:

Sand Filter Pack 4-6 ft below grade

Sheet 1 of 1COMPLETION REPORT OF WELL No. SB-SGW-4

TRC

0.25" OD (0.17" ID)

Nylon Tubing 0 - 4.5 ft below grade

Type:

Interval:

PROTECTIVE CASING

648.40

Type:

Interval:

WELL DEVELOPMENT DATA

DATE:

METHOD:

NA

NA

Diameter:

Type:

Interval:

0.5" ID

Stainless Steel Implant 4.5-5 ft below grade

Bentonite Chips 1 - 4 ft below grade

Terra Probe

Direct Push

7/28/2010

GROUT

RISER CASING

5.50 7/28/10

CONCRETE

CEMENT/BENTONITE GROUT

FILTER PACK

BENTONITE

BENTONITE/NATURAL COLLAPSE

FILL

SAND

SILT

CLAY

GRAVELLY CLAY

ASPHALT

TOPSOIL

INTERBEDDED SAND, SILT, CLAY

COMPLETION REPORT OF

WELL No. SB-SGW-4

Sheet 1 of 1

TPC

TRC

GS

TOP OF PROTECTIVE CASING

TOP OF RISER CASING

GROUND SURFACE

LEGEND

101 South Washington Square, Suite 400 Lansing, MI 48933

4.50

8.00

648.20

645.70

644.70

641.20

Concrete

Bentonite Chips

Filter Pack Sand Stainless Steel Implant

D E

P T

H (f t.)

CONSTRUCTION

REMARKS

E

LE

V A

T

IO

N (f t.)

WELL

DETAILS

S Y

M B

O L

D E

P T

H (f t.)WELL CONSTRUCTION DETAILS V A

S

STRATA

0.0

WATER LEVEL:

DATE:

TIME:

Wayne Oakland Oil 3940096 Royal Oak, MI

SEAL

DRILLING CONTRACTOR:

DRILLING METHOD:

DATE COMPLETED:

0.00NA

Type:

Interval:

None None

GS

SANDPACK

Diameter:

Type:

Interval:

Diameter:

Type:

Interval:

649.2

USGS

M. Brennan

7" Steel 0 ft above grade to 1 ft below grade

SCREEN

PROJECT:

PROJECT NO:

PROJECT LOCATION:

GROUND SURFACE ELEVATION:

DATUM:

LOGGED BY:

Sand Filter Pack 3.5-8 ft below grade

Sheet 1 of 1COMPLETION REPORT OF WELL No. SB-SGW-5

TRC

0.25" OD (0.17" ID)

Nylon Tubing 0 - 4 ft below grade

Type:

Interval:

PROTECTIVE CASING

649.20

Type:

Interval:

WELL DEVELOPMENT DATA

DATE:

METHOD:

NA

NA

Diameter:

Type:

Interval:

0.5" ID

Stainless Steel Implant 4-4.5 ft below grade

Bentonite Chips 1 - 3.5 ft below grade

Terra Probe

Direct Push

7/28/2010

GROUT

RISER CASING

5.50 7/28/10

CONCRETE

CEMENT/BENTONITE GROUT

FILTER PACK

BENTONITE

BENTONITE/NATURAL COLLAPSE

FILL

SAND

SILT

CLAY

GRAVELLY CLAY

ASPHALT

TOPSOIL

INTERBEDDED SAND, SILT, CLAY

COMPLETION REPORT OF

WELL No. SB-SGW-5

Sheet 1 of 1

TPC

TRC

GS

TOP OF PROTECTIVE CASING

TOP OF RISER CASING

GROUND SURFACE

LEGEND

101 South Washington Square, Suite 400 Lansing, MI 48933

4.50

8.00

647.70

645.20

644.20

640.70

Concrete

Bentonite Chips

Filter Pack Sand Stainless Steel Implant

D E

P T

H (f t.)

CONSTRUCTION

REMARKS

E

LE

V A

T

IO

N (f t.)

WELL

DETAILS

S Y

M B

O L

D E

P T

H (f t.)WELL CONSTRUCTION DETAILS V A

S

STRATA

0.0

WATER LEVEL:

DATE:

TIME:

Wayne Oakland Oil 3940096 Royal Oak, MI

SEAL

DRILLING CONTRACTOR:

DRILLING METHOD:

DATE COMPLETED:

0.00NA

Type:

Interval:

None None

GS

SANDPACK

Diameter:

Type:

Interval:

Diameter:

Type:

Interval:

648.7

USGS

M. Brennan

7" Steel 0 ft above grade to 1 ft below grade

SCREEN

PROJECT:

PROJECT NO:

PROJECT LOCATION:

GROUND SURFACE ELEVATION:

DATUM:

LOGGED BY:

Sand Filter Pack 3.5-8 ft below grade

Sheet 1 of 1COMPLETION REPORT OF WELL No. SB-SGW-6

TRC

0.25" OD (0.17" ID)

Nylon Tubing 0 - 4 ft below grade

Type:

Interval:

PROTECTIVE CASING

648.70

Type:

Interval:

WELL DEVELOPMENT DATA

DATE:

METHOD:

NA

NA

Diameter:

Type:

Interval:

0.5" ID

Stainless Steel Implant 4-4.5 ft below grade

Bentonite Chips 1 - 3.5 ft below grade

Terra Probe

Direct Push

7/28/2010

GROUT

RISER CASING

6.00 7/28/10

CONCRETE

CEMENT/BENTONITE GROUT

FILTER PACK

BENTONITE

BENTONITE/NATURAL COLLAPSE

FILL

SAND

SILT

CLAY

GRAVELLY CLAY

ASPHALT

TOPSOIL

INTERBEDDED SAND, SILT, CLAY

COMPLETION REPORT OF

WELL No. SB-SGW-6

Sheet 1 of 1

TPC

TRC

GS

TOP OF PROTECTIVE CASING

TOP OF RISER CASING

GROUND SURFACE

LEGEND

101 South Washington Square, Suite 400 Lansing, MI 48933

4.50

6.00

647.60

645.10

644.10

642.60

Concrete

Bentonite Chips

Filter Pack Sand Stainless Steel Implant

D E

P T

H (f t.)

CONSTRUCTION

REMARKS

E

LE

V A

T

IO

N (f t.)

WELL

DETAILS

S Y

M B

O L

D E

P T

H (f t.)WELL CONSTRUCTION DETAILS V A

S

STRATA

0.0

WATER LEVEL:

DATE:

TIME:

Wayne Oakland Oil 3940096 Royal Oak, MI

SEAL

DRILLING CONTRACTOR:

DRILLING METHOD:

DATE COMPLETED:

0.00NA

Type:

Interval:

None None

GS

SANDPACK

Diameter:

Type:

Interval:

Diameter:

Type:

Interval:

648.6

USGS

M. Brennan

7" Steel 0 ft above grade to 1 ft below grade

SCREEN

PROJECT:

PROJECT NO:

PROJECT LOCATION:

GROUND SURFACE ELEVATION:

DATUM:

LOGGED BY:

Sand Filter Pack 3.5-6 ft below grade

Sheet 1 of 1COMPLETION REPORT OF WELL No. SB-SGW-7

TRC

0.25" OD (0.17" ID)

Nylon Tubing 0 - 4 ft below grade

Type:

Interval:

PROTECTIVE CASING

648.60

Type:

Interval:

WELL DEVELOPMENT DATA

DATE:

METHOD:

NA

NA

Diameter:

Type:

Interval:

0.5" ID

Stainless Steel Implant 4-4.5 ft below grade

Bentonite Chips 1 - 3.5 ft below grade

Terra Probe

Direct Push

7/28/2010

GROUT

RISER CASING

5.50 7/28/10

CONCRETE

CEMENT/BENTONITE GROUT

FILTER PACK

BENTONITE

BENTONITE/NATURAL COLLAPSE

FILL

SAND

SILT

CLAY

GRAVELLY CLAY

ASPHALT

TOPSOIL

INTERBEDDED SAND, SILT, CLAY

COMPLETION REPORT OF

WELL No. SB-SGW-7

Sheet 1 of 1

TPC

TRC

GS

TOP OF PROTECTIVE CASING

TOP OF RISER CASING

GROUND SURFACE

LEGEND

101 South Washington Square, Suite 400 Lansing, MI 48933

MICHIGAN DEPARTMENT OF ENVIRONMENTAL QUALITY

ENVIRONMENTAL LABORATORY

P.O. Box 30270

Lansing, MI 48909

TEL: (517) 335-9800

FAX: (517) 335-9600

RRDDivision:

Report to: CHRISTY CLARK 91200045

Work Site ID : 63000838

WAYNE OAKLAND OIL

Received:

Reported:

Collected By: MIKE BRENNAN

12/02/2009

01/13/2010

MDEQ-RRD-WARREN

SOUTHEAST MICHIGAN DISTRICT OFF

27700 DONALD COURT, WARREN, MI 48092-2793

$2,589.50Total:

Lab Work Order # :

Site Name :

Sample Description Collection DateSample ID Matrix:No:

Samples Received :

AB47450 12/01/2009MW-4 WATER01

AB47451 12/01/2009MW-2 WATER02

AB47452 12/01/2009MW-2 MS WATER03

AB47453 12/01/2009MW-2 MSD WATER04

AB47454 12/01/2009FIELD BLANK WATER05

AB47455 12/01/2009DUP-1 WATER06

AB47456 11/24/2009TRIP BLANK WATER07

AB47457 12/02/2009WASTE (LIQUID DRUM) WATER08

I certify that the analysis performed by the MDEQ Environmental Laboratory are accurate and that the laboratory tests were conducted by methods approved by the U.S. Environmental Protection Agency and other appropriate regulatory agencies.

Bob Avery, Laboratory Director

Page 1 of 4091200045Lab Work Order #:

P.O. Box 30270

Lansing, MI 48909

TEL: (517) 335-9800

FAX: (517) 335-9600

Sample Number: AB47457 WASTE (LIQUID DRUM)

Volatile Compounds

Compound

Date Tested:

RL

Analytical Method:

CAS #

8260 Analyst:

Qualifier

12/04/2009 KCL

Dilution FactorResult ug/L

SURROGATE #Bromofluorobenzene# 96.6

SURROGATE #Dibromofluoromethane# 101

SURROGATE #Toluene-d8# 94.4

630-20-6 1,1,1,2-Tetrachloroethane 10 10Not Detected

71-55-6 1,1,1-Trichloroethane 10 10Not Detected

79-34-5 1,1,2,2-Tetrachloroethane 10 10Not Detected

79-00-5 1,1,2-Trichloroethane 10 10Not Detected

75-34-3 1,1-Dichloroethane 10 10Not Detected

75-35-4 1,1-Dichloroethylene 10 10Not Detected

87-61-6 1,2,3-Trichlorobenzene 50 10Not Detected

96-18-4 1,2,3-Trichloropropane 10 10Not Detected

526-73-8 1,2,3-Trimethylbenzene 10 1068

120-82-1 1,2,4-Trichlorobenzene 50 10Not Detected

95-63-6 1,2,4-Trimethylbenzene 10 10160

96-12-8 1,2-Dibromo-3-chloropropane 50 10Not Detected

106-93-4 1,2-Dibromoethane 10 10Not Detected

95-50-1 1,2-Dichlorobenzene 10 10Not Detected

107-06-2 1,2-Dichloroethane 10 10Not Detected

78-87-5 1,2-Dichloropropane 10 10Not Detected

108-67-8 1,3,5-Trimethylbenzene 10 1029

541-73-1 1,3-Dichlorobenzene 10 10Not Detected

106-46-7 1,4-Dichlorobenzene 10 10Not Detected

78-93-3 2-Butanone (MEK) 50 10Not Detected

591-78-6 2-Hexanone 50 10Not Detected

91-57-6 2-Methylnaphthalene X50 10210

67-64-1 2-Propanone (acetone) 200 10Not Detected

108-10-1 4-Methyl-2-pentanone (MIBK) 50 10Not Detected

107-13-1 Acrylonitrile Z50 10Not Detected

71-43-2 Benzene 10 10Not Detected

108-86-1 Bromobenzene 10 10Not Detected

74-97-5 Bromochloromethane 10 10Not Detected

75-27-4 Bromodichloromethane 10 10Not Detected

75-25-2 Bromoform 10 10Not Detected

74-83-9 Bromomethane 50 10Not Detected

75-15-0 Carbon disulfide 10 10Not Detected

56-23-5 Carbon tetrachloride 10 10Not Detected

108-90-7 Chlorobenzene 10 10Not Detected

75-00-3 Chloroethane 50 10Not Detected

67-66-3 Chloroform 10 10Not Detected

74-87-3 Chloromethane 50 10Not Detected

156-59-2 cis-1,2-Dichloroethylene 10 10Not Detected

CAS# : Chemical Abstract Service Registry Number

RL : Reporting Limit

ND : Not Detected ug / L : microgram / liter (ppb) mg / L : milligram / liter (ppm) ug / Kg : microgram / kilogram (ppb) mg / Kg : milligram / kilogram (ppm)

Laboratory Contacts

Inorganic Unit Mgr: Sandy Gregg

Organic Unit Mgr: Carol Smith

Systems Mgmt Unit: George Krisztian

Page 34 of 4091200045Lab Work Order #:

P.O. Box 30270

Lansing, MI 48909

TEL: (517) 335-9800

FAX: (517) 335-9600

Sample Number: AB47457 WASTE (LIQUID DRUM)

Volatile Compounds

Compound

Date Tested:

RL

Analytical Method:

CAS #

8260 Analyst:

Qualifier

12/04/2009 KCL

Dilution FactorResult ug/L

10061-01-5 cis-1,3-Dichloropropylene 10 10Not Detected

110-82-7 Cyclohexane 50 10Not Detected

124-48-1 Dibromochloromethane 10 10Not Detected

74-95-3 Dibromomethane 10 10Not Detected

75-71-8 Dichlorodifluoromethane 50 10Not Detected

60-29-7 Diethyl ether 50 10Not Detected

108-20-3 Diisopropyl Ether 50 10Not Detected

100-41-4 Ethylbenzene 10 1026

637-92-3 Ethyltertiarybutylether 50 10Not Detected

67-72-1 Hexachloroethane 50 10Not Detected

98-82-8 Isopropylbenzene 10 1016

108383,106423 m & p - Xylene 20 1044

74-88-4 Methyl iodide 10 10Not Detected

75-09-2 Methylene chloride 50 10Not Detected

1634-04-4 Methyltertiarybutylether 10 10Not Detected

91-20-3 Naphthalene X50 10170

104-51-8 n-Butylbenzene 10 10Not Detected

103-65-1 n-Propylbenzene 10 1023

95-47-6 o-Xylene 10 10Not Detected

99-87-6 p-Isopropyl toluene 10 1011

135-98-8 sec-Butylbenzene 10 10Not Detected

100-42-5 Styrene 10 10Not Detected

98-06-6 tert-Butylbenzene 10 10Not Detected

75-65-0 tertiary Butyl Alcohol 500 10Not Detected

994-05-8 tertiaryAmylmethylether 50 10Not Detected

127-18-4 Tetrachloroethylene 10 10Not Detected

109-99-9 Tetrahydrofuran 50 10Not Detected

108-88-3 Toluene 10 10Not Detected

156-60-5 trans-1,2-Dichloroethylene 10 10Not Detected

10061-02-6 trans-1,3-Dichloropropylene 10 10Not Detected

110-57-6 trans-1,4-Dichloro-2-butene Z50 10Not Detected

79-01-6 Trichloroethylene 10 10Not Detected

75-69-4 Trichlorofluoromethane 10 10Not Detected

75-01-4 Vinyl chloride 10 10Not Detected

Unidentified peaks present in sample.

Base Neutral Acid Compounds

Compound

Date Tested:

RL

Analytical Method:

CAS #

8270 Analyst:

Qualifier

12/10/2009 SMH

Extraction Method: Extraction Date: 12/04/2009 1000Volume:3510 KQualifier:

Dilution FactorResult ug/L

CAS# : Chemical Abstract Service Registry Number

RL : Reporting Limit

ND : Not Detected ug / L : microgram / liter (ppb) mg / L : milligram / liter (ppm) ug / Kg : microgram / kilogram (ppb) mg / Kg : milligram / kilogram (ppm)

Laboratory Contacts

Inorganic Unit Mgr: Sandy Gregg

Organic Unit Mgr: Carol Smith

Page 35 of 4091200045Lab Work Order #:

P.O. Box 30270

Lansing, MI 48909

TEL: (517) 335-9800

FAX: (517) 335-9600

Sample Number: AB47457 WASTE (LIQUID DRUM)

Base Neutral Acid Compounds

Compound

Date Tested:

RL

Analytical Method:

CAS #

8270 Analyst:

Qualifier

12/10/2009 SMH

Extraction Method: Extraction Date: 12/04/2009 1000Volume:3510 KQualifier:

Dilution FactorResult ug/L

SURROGATE #2 - Fluorobiphenyl# VNot Applicable

SURROGATE #2,4,6-Tribromophenol# VNot Applicable

SURROGATE #2-Fluorophenol# VNot Applicable

SURROGATE #Nitrobenzene - D5# VNot Applicable

SURROGATE #Phenol - D6# VNot Applicable

SURROGATE #p-Terphenyl-D14# VNot Applicable

120-82-1 1,2,4-Trichlorobenzene 5000 2500Not Detected

95-95-4 2,4,5-Trichlorophenol 13000 2500Not Detected

88-06-2 2,4,6-Trichlorophenol 10000 2500Not Detected

120-83-2 2,4-Dichlorophenol 25000 2500Not Detected

105-67-9 2,4-Dimethylphenol 13000 2500Not Detected

51-28-5 2,4-Dinitrophenol 63000 2500Not Detected

121-14-2 2,4-Dinitrotoluene 13000 2500Not Detected

606-20-2 2,6-Dinitrotoluene 13000 2500Not Detected

95-51-2 2-Chloroaniline 13000 2500Not Detected

91-58-7 2-Chloronaphthalene 5000 2500Not Detected

95-57-8 2-Chlorophenol 25000 2500Not Detected

534-52-1 2-Methyl-4,6-dinitrophenol 50000 2500Not Detected

91-57-6 2-Methylnaphthalene 13000 250064000

95-48-7 2-Methylphenol (o-Cresol) 25000 2500Not Detected

88-74-4 2-Nitroaniline 50000 2500Not Detected

88-75-5 2-Nitrophenol 13000 2500Not Detected

108394,106445 3 & 4-Methylphenol 50000 2500Not Detected

99-09-2 3-Nitroaniline 50000 2500Not Detected

101-55-3 4-Bromophenyl phenyl ether 5000 2500Not Detected

59-50-7 4-Chloro-3-methyl-phenol 13000 2500Not Detected

106-47-8 4-Chloroaniline 25000 2500Not Detected

7005-72-3 4-Chlorodiphenylether 2500 2500Not Detected

100-01-6 4-Nitroaniline 50000 2500Not Detected

100-02-7 4-Nitrophenol 63000 2500Not Detected

83-32-9 Acenaphthene 2500 25005000

208-96-8 Acenaphthylene 2500 2500Not Detected

62-53-3 Aniline 10000 2500Not Detected

120-12-7 Anthracene 2500 2500Not Detected

103-33-3 Azobenzene 5000 2500Not Detected

56-55-3 Benzo[a]anthracene 2500 2500Not Detected

50-32-8 Benzo[a]pyrene 2500 2500Not Detected

205-99-2 Benzo[b]fluoranthene 2500 2500Not Detected

191-24-2 Benzo[g,h,i]perylene 2500 2500Not Detected

207-08-9 Benzo[k]fluoranthene 2500 2500Not Detected

100-51-6 Benzyl Alcohol 130000 2500Not Detected

CAS# : Chemical Abstract Service Registry Number

RL : Reporting Limit

ND : Not Detected ug / L : microgram / liter (ppb) mg / L : milligram / liter (ppm) ug / Kg : microgram / kilogram (ppb) mg / Kg : milligram / kilogram (ppm)

Laboratory Contacts

Inorganic Unit Mgr: Sandy Gregg

Organic Unit Mgr: Carol Smith

Page 36 of 4091200045Lab Work Order #:

P.O. Box 30270

Lansing, MI 48909

TEL: (517) 335-9800

FAX: (517) 335-9600

Sample Number: AB47457 WASTE (LIQUID DRUM)

Base Neutral Acid Compounds

Compound

Date Tested:

RL

Analytical Method:

CAS #

8270 Analyst:

Qualifier

12/10/2009 SMH

Extraction Method: Extraction Date: 12/04/2009 1000Volume:3510 KQualifier:

Dilution FactorResult ug/L

111-91-1 Bis(2-chloroethoxy)methane 5000 2500Not Detected

111-44-4 Bis(2-chloroethyl)ether 2500 2500Not Detected

108-60-1 Bis(2-chloroisopropyl)ether 52500 2500Not Detected

117-81-7 Bis(2-ethylhexyl)phthalate 13000 2500Not Detected

85-68-7 Butyl benzyl phthalate 13000 2500Not Detected

86-74-8 Carbazole 13000 2500Not Detected

218-01-9 Chrysene 2500 2500Not Detected

53-70-3 Dibenz[a,h]anthracene 5000 2500Not Detected

132-64-9 Dibenzofuran 10000 2500Not Detected

84-66-2 Diethylphthalate 13000 2500Not Detected

131-11-3 Dimethyl phthalate 13000 2500Not Detected

84-74-2 Di-n-butyl phthalate 13000 2500Not Detected

117-84-0 Di-n-octyl phthalate 13000 2500Not Detected

206-44-0 Fluoranthene 2500 2500Not Detected

86-73-7 Fluorene 2500 25007400

118-74-1 Hexachlorobenzene 2500 2500Not Detected

87-68-3 Hexachlorobutadiene 2500 2500Not Detected

77-47-4 Hexachlorocyclopentadiene Z25000 2500Not Detected

67-72-1 Hexachloroethane 2500 2500Not Detected

193-39-5 Indeno(1,2,3-c,d)pyrene 5000 2500Not Detected

78-59-1 Isophorone 2500 2500Not Detected

121-69-7 N,N-dimethylaniline 13000 2500Not Detected

91-20-3 Naphthalene 2500 250023000

98-95-3 Nitrobenzene 5000 2500Not Detected

100-61-8 N-methylaniline 2500 2500Not Detected

67-75-9 N-Nitrosodimethylamine 513000 2500Not Detected

621-64-7 N-Nitrosodi-n-propylamine 55000 2500Not Detected

86-30-6 N-Nitrosodiphenylamine 5000 2500Not Detected

87-86-5 Pentachlorophenol 50000 2500Not Detected

85-01-8 Phenanthrene 2500 250015000

108-95-2 Phenol 13000 2500Not Detected

129-00-0 Pyrene 2500 2500Not Detected

110-86-1 Pyridine 550000 2500Not Detected

632-22-4 Tetramethylurea 2500 2500Not Detected

RLs raised due to matrix interference.

Probable petroleum product(s) present.

CAS# : Chemical Abstract Service Registry Number

RL : Reporting Limit

ND : Not Detected ug / L : microgram / liter (ppb) mg / L : milligram / liter (ppm) ug / Kg : microgram / kilogram (ppb) mg / Kg : milligram / kilogram (ppm)

Laboratory Contacts

Inorganic Unit Mgr: Sandy Gregg

Organic Unit Mgr: Carol Smith

Page 37 of 4091200045Lab Work Order #:

P.O. Box 30270

Lansing, MI 48909

TEL: (517) 335-9800

FAX: (517) 335-9600

Sample Number: AB47457 WASTE (LIQUID DRUM)

Pesticide Compounds

Compound

Date Tested:

RL

Analytical Method:

CAS #

8081 Analyst:

Qualifier

12/16/2009 MF

Extraction Method: Extraction Date: 12/08/2009 1000Volume:3510 Qualifier:

Dilution FactorResult ug/L

SURROGATE #Decachlorobiphenyl# VNot Applicable

SURROGATE #Tetrachloro-m-xylene# VNot Applicable

72-54-8 4,4'-DDD 15 500Not Detected

72-55-9 4,4'-DDE 10 500Not Detected

50-29-3 4,4'-DDT 25 500Not Detected

319-84-6 a-BHC 10 500Not Detected

5103-71-9 a-Chlordane 5 500Not Detected

309-00-2 Aldrin 5 500Not Detected

319-85-7 b-BHC 10 500Not Detected

319-86-8 d-BHC 10 500Not Detected

60-57-1 Dieldrin 10 500Not Detected

959-98-8 Endosulfan I 10 500Not Detected

33213-65-9 Endosulfan II 15 500Not Detected

1031-07-8 Endosulfan sulfate 25 500Not Detected

72-20-8 Endrin 10 500Not Detected

7421-93-4 Endrin aldehyde 10 500Not Detected

53494-70-5 Endrin ketone 10 500Not Detected

58-89-9 g-BHC (Lindane) 10 500Not Detected

5103-74-2 g-Chlordane 5 500Not Detected

76-44-8 Heptachlor 5 500Not Detected

1024-57-3 Heptachlor epoxide 5 500Not Detected

87-82-1 Hexabromobenzene 10 500Not Detected

72-43-5 Methoxychlor 25 500Not Detected

2385-85-5 Mirex 10 500Not Detected

59080-40-9 PBB (BP-6) 25 500Not Detected

8001-35-2 Toxaphene 50 500Not Detected

RLs raised due to matrix interference.

CAS# : Chemical Abstract Service Registry Number

RL : Reporting Limit

ND : Not Detected ug / L : microgram / liter (ppb) mg / L : milligram / liter (ppm) ug / Kg : microgram / kilogram (ppb) mg / Kg : milligram / kilogram (ppm)

Laboratory Contacts

Inorganic Unit Mgr: Sandy Gregg

Organic Unit Mgr: Carol Smith

Page 38 of 4091200045Lab Work Order #:

P.O. Box 30270

Lansing, MI 48909

TEL: (517) 335-9800

FAX: (517) 335-9600

Sample Number: AB47457 WASTE (LIQUID DRUM)

Date TestedAnalyte Name MethodCAS# QualifierResult AnalystRLUnit

Digestion Metals Water KS3010/20012/15/2009Completed

Flash Point TK101012/18/2009degrees C83.5

Digestion Mercury Water TS7470/245.112/17/2009Completed

7439-97-6 Mercury - Total TS7470/245.112/18/2009µg/LND 0.2

7440-38-2 Arsenic - Total KS6020/200.812/21/2009µg/L110 1

7440-39-3 Barium - Total KS6020/200.812/21/2009µg/L140 5

7440-43-9 Cadmium - Total I KS6020/200.812/16/2009µg/LND 2

7440-47-3 Chromium - Total KS6020/200.812/16/2009µg/L41 1

7440-50-8 Copper - Total KS6020/200.812/16/2009µg/L33 1

7439-92-1 Lead - Total D KS6020/200.812/21/2009µg/L2200 1

7782-49-2 Selenium - Total I KS6020/200.812/21/2009µg/LND 10

7440-22-4 Silver -Total I KS6020/200.812/16/2009µg/LND 2

7440-66-6 Zinc - Total KS6020/200.812/16/2009µg/L160 10 pH LU4500H B SM12/09/2009pH8

Due to the oily nature of the sample a pH strip was used to determine the pH of the sample.

Florisil Cleanup DT362012/15/2009Completed

Gel Permeation Cleanup DT364012/14/2009Completed

CAS# : Chemical Abstract Service Registry Number

RL : Reporting Limit

ND : Not Detected ug / L : microgram / liter (ppb) mg / L : milligram / liter (ppm) ug / Kg : microgram / kilogram (ppb) mg / Kg : milligram / kilogram (ppm)

Laboratory Contacts

Inorganic Unit Mgr: Sandy Gregg

Organic Unit Mgr: Carol Smith

Page 39 of 4091200045Lab Work Order #:

P.O. Box 30270

Lansing, MI 48909

TEL: (517) 335-9800

FAX: (517) 335-9600

Qualifier DescriptionQualifier Code

1 Result(s) and RL(s) are estimated due to low surrogate recovery.

2 Result is estimated due to high surrogate recovery.

3 Result(s) and RL(s) are estimated due to low matrix spike recovery.

4 Result is estimated due to high matrix spike recovery.

5 Result and RL are estimated due to low continuing calibration standard criteria failure.

6 Result is estimated due to high continuing calibration standard criteria failure.

7 Result(s) and RL(s) are estimated due to poor precision.

8 Result(s) and RL(s) are estimated due to low recovery of batch QC.

9 Result outside QC acceptance criteria.

A Value reported is the mean of two or more determinations.

C Value calculated from other independent parameters.

D Analyte value quantified from a dilution(s); reporting limit (RL) raised.

E Result is estimated due to high recovery of batch QC.

F Amenable cyanide was not analyzed due to low level of total cyanide.

G Result and RL are estimated due to initial calibration standard criteria failure.

H Recommended laboratory holding time was exceeded.

I Dilution required due to matrix interference; reporting limit (RL) raised.

J Analyte was positively identified. Value is an estimate.

JA Result is estimated due to multiple Aroclors present.

JC Result is estimated since confirmation analysis did not meet acceptance criteria

JD Due to severe degradation, specific Aroclor identification is difficult and quantitation is estimated.

K RL(s) raised due to matrix interferences.

KR RL(s) raised due to low sample volume submitted.

KS RL(s) raised due to low total solids.

KW RL(s) raised due to light sample weight.

LB Reported library search compounds are tentative identifications with estimated concentrations.

M The level of the method preparation blank (MPB) is reported in the qualifier column.

N Non-homogeneous sample made analysis of sample questionable.

O Result and RL estimated due to analysis from an open vial.

P Recommended sample collection/preservation technique not used; reported result(s) is an estimate.

Q Quantity of sample insufficient to perform analyses requested.

R Result confirmed by re-extraction and analysis.

S Supernatant analyzed.

T Reported value is less than the reporting limit (RL). Result is estimated.

V Value not available due to dilution.

W Reported value is less than the method detection limit (MDL).

X Methods 8260 & 624 are used to analyze volatile organics that have boiling points below 200°C.

2-Methylnaphthalene & naphthalene have boiling points above 200°C and are better suited to analysis by methods 8270 or 625 as semivolatile organics.

PI Possible interference may have affected the accuracy of the laboratory result

Z Result reported below the RL to meet the TDL in RRD Op Memo 2 (10/22/04) multiplied by applicable dilution factor.

CAS# : Chemical Abstract Service Registry Number

RL : Reporting Limit

ND : Not Detected ug / L : microgram / liter (ppb) mg / L : milligram / liter (ppm) ug / Kg : microgram / kilogram (ppb) mg / Kg : milligram / kilogram (ppm)

Laboratory Contacts

Inorganic Unit Mgr: Sandy Gregg

Organic Unit Mgr: Carol Smith

Page 40 of 4091200045Lab Work Order #:

P.O. Box 30270

Lansing, MI 48909

TEL: (517) 335-9800

FAX: (517) 335-9600

RRDDivision:

Report to: CHRISTY CLARK 91200046

Work Site ID : 63000838

WAYNE OAKLAND OIL

Received:

Reported:

Collected By: MIKE BRENNAN

12/02/2009

01/14/2010

MDEQ-RRD-WARREN

SOUTHEAST MICHIGAN DISTRICT OFF

27700 DONALD COURT, WARREN, MI 48092-2793

$804.50Total:

Lab Work Order # :

Site Name :

Sample Description Collection DateSample ID Matrix:No:

Samples Received :

AB47458 12/02/2009WASTE (SOIL DRUM) SEDIMENT01

I certify that the analysis performed by the MDEQ Environmental Laboratory are accurate and that the laboratory tests were conducted by methods approved by the U.S. Environmental Protection Agency and other appropriate regulatory agencies.

Page 1 of 891200046Lab Work Order #:

P.O. Box 30270

Lansing, MI 48909

TEL: (517) 335-9800

FAX: (517) 335-9600

Sample Number: AB47458 WASTE (SOIL DRUM)

TCLP Volatile Leachate

Compound

Date Tested:

RL

Analytical Method:

CAS #

8260 Analyst:

Qualifier

12/15/2009 KCL

Extraction Method: Extraction Date: 12/03/20091311 Qualifier:

Dilution FactorResult ug/L

SURROGATE #Bromofluorobenzene# 98.2

SURROGATE #Dibromofluoromethane# 98.3

SURROGATE #Toluene-d8# 94.8

630-20-6 1,1,1,2-Tetrachloroethane 1 1.0Not Detected

71-55-6 1,1,1-Trichloroethane 1 1.0Not Detected

79-34-5 1,1,2,2-Tetrachloroethane 1 1.0Not Detected

79-00-5 1,1,2-Trichloroethane 1 1.0Not Detected

75-34-3 1,1-Dichloroethane 1 1.0Not Detected

75-35-4 1,1-Dichloroethylene 1 1.0Not Detected

87-61-6 1,2,3-Trichlorobenzene 5 1.0Not Detected

96-18-4 1,2,3-Trichloropropane 1 1.0Not Detected

526-73-8 1,2,3-Trimethylbenzene 1 1.06.5

120-82-1 1,2,4-Trichlorobenzene 5 1.0Not Detected

95-63-6 1,2,4-Trimethylbenzene 1 1.01.6

96-12-8 1,2-Dibromo-3-chloropropane 5 1.0Not Detected

106-93-4 1,2-Dibromoethane 1 1.0Not Detected

95-50-1 1,2-Dichlorobenzene 1 1.0Not Detected

107-06-2 1,2-Dichloroethane 1 1.0Not Detected

78-87-5 1,2-Dichloropropane 1 1.0Not Detected

108-67-8 1,3,5-Trimethylbenzene 1 1.02.9

541-73-1 1,3-Dichlorobenzene 1 1.0Not Detected

106-46-7 1,4-Dichlorobenzene 1 1.0Not Detected

78-93-3 2-Butanone (MEK) 5 1.0Not Detected

591-78-6 2-Hexanone 5 1.0Not Detected

91-57-6 2-Methylnaphthalene X5 1.06.5

67-64-1 2-Propanone (acetone) 20 1.0Not Detected

108-10-1 4-Methyl-2-pentanone (MIBK) 5 1.0Not Detected

107-13-1 Acrylonitrile Z5 1.0Not Detected

71-43-2 Benzene 1 1.0Not Detected

108-86-1 Bromobenzene 1 1.0Not Detected

74-97-5 Bromochloromethane 1 1.0Not Detected

75-27-4 Bromodichloromethane 1 1.0Not Detected

75-25-2 Bromoform 1 1.0Not Detected

74-83-9 Bromomethane 5 1.0Not Detected

75-15-0 Carbon disulfide 1 1.0Not Detected

56-23-5 Carbon tetrachloride 1 1.0Not Detected

108-90-7 Chlorobenzene 1 1.0Not Detected

75-00-3 Chloroethane 5 1.0Not Detected

67-66-3 Chloroform 1 1.0Not Detected

74-87-3 Chloromethane 5 1.0Not Detected

156-59-2 cis-1,2-Dichloroethylene 1 1.0Not Detected

CAS# : Chemical Abstract Service Registry Number

RL : Reporting Limit

ND : Not Detected ug / L : microgram / liter (ppb) mg / L : milligram / liter (ppm) ug / Kg : microgram / kilogram (ppb) mg / Kg : milligram / kilogram (ppm)

Laboratory Contacts

Inorganic Unit Mgr: Sandy Gregg

Organic Unit Mgr: Carol Smith

Page 2 of 891200046Lab Work Order #:

P.O. Box 30270

Lansing, MI 48909

TEL: (517) 335-9800

FAX: (517) 335-9600

Sample Number: AB47458 WASTE (SOIL DRUM)

TCLP Volatile Leachate

Compound

Date Tested:

RL

Analytical Method:

CAS #

8260 Analyst:

Qualifier

12/15/2009 KCL

Extraction Method: Extraction Date: 12/03/20091311 Qualifier:

Dilution FactorResult ug/L

10061-01-5 cis-1,3-Dichloropropylene 1 1.0Not Detected

110-82-7 Cyclohexane 5 1.0Not Detected

124-48-1 Dibromochloromethane 1 1.0Not Detected

74-95-3 Dibromomethane 1 1.0Not Detected

75-71-8 Dichlorodifluoromethane 5 1.0Not Detected

60-29-7 Diethyl ether 5 1.0Not Detected

108-20-3 Diisopropyl Ether 5 1.0Not Detected

100-41-4 Ethylbenzene 1 1.0Not Detected

637-92-3 Ethyltertiarybutylether 5 1.0Not Detected

67-72-1 Hexachloroethane 5 1.0Not Detected

98-82-8 Isopropylbenzene 1 1.0Not Detected

108383,106423 m & p - Xylene 2 1.0Not Detected

74-88-4 Methyl iodide 1 1.0Not Detected

75-09-2 Methylene chloride 5 1.0Not Detected

1634-04-4 Methyltertiarybutylether 1 1.0Not Detected

91-20-3 Naphthalene X5 1.0Not Detected

104-51-8 n-Butylbenzene 1 1.0Not Detected

103-65-1 n-Propylbenzene 1 1.0Not Detected

95-47-6 o-Xylene 1 1.0Not Detected

99-87-6 p-Isopropyl toluene 1 1.0Not Detected

135-98-8 sec-Butylbenzene 1 1.0Not Detected

100-42-5 Styrene 1 1.0Not Detected

98-06-6 tert-Butylbenzene 1 1.0Not Detected

75-65-0 tertiary Butyl Alcohol 50 1.0Not Detected

994-05-8 tertiaryAmylmethylether 5 1.0Not Detected

127-18-4 Tetrachloroethylene 1 1.0Not Detected

109-99-9 Tetrahydrofuran 5 1.0Not Detected

108-88-3 Toluene 1 1.0Not Detected

156-60-5 trans-1,2-Dichloroethylene 1 1.0Not Detected

10061-02-6 trans-1,3-Dichloropropylene 1 1.0Not Detected

110-57-6 trans-1,4-Dichloro-2-butene Z5 1.0Not Detected

79-01-6 Trichloroethylene 1 1.0Not Detected

75-69-4 Trichlorofluoromethane 1 1.0Not Detected

75-01-4 Vinyl chloride 1 1.0Not Detected

TCLP Base Neutral Acid Compounds

Compound

Date Tested:

RL

Analytical Method:

CAS #

8270 Analyst:

Qualifier

12/15/2009 SMH

Extraction Method: Extraction Date: 12/10/20093510 Qualifier:

Dilution FactorResult ug/L

CAS# : Chemical Abstract Service Registry Number

RL : Reporting Limit

ND : Not Detected ug / L : microgram / liter (ppb) mg / L : milligram / liter (ppm) ug / Kg : microgram / kilogram (ppb) mg / Kg : milligram / kilogram (ppm)

Laboratory Contacts

Inorganic Unit Mgr: Sandy Gregg

Organic Unit Mgr: Carol Smith

Page 3 of 891200046Lab Work Order #:

P.O. Box 30270

Lansing, MI 48909

TEL: (517) 335-9800

FAX: (517) 335-9600

Sample Number: AB47458 WASTE (SOIL DRUM)

TCLP Base Neutral Acid Compounds

Compound

Date Tested:

RL

Analytical Method:

CAS #

8270 Analyst:

Qualifier

12/15/2009 SMH

Extraction Method: Extraction Date: 12/10/20093510 Qualifier:

Dilution FactorResult ug/L

SURROGATE #2 - Fluorobiphenyl# 70.1

SURROGATE #2,4,6-Tribromophenol# 78.6

SURROGATE #2-Fluorophenol# 29.2

SURROGATE #Nitrobenzene - D5# 85.1

SURROGATE #Phenol - D6# 19.2

SURROGATE #p-Terphenyl-d14# 84.5

120-82-1 1,2,4-Trichlorobenzene 2 1.0Not Detected

95-95-4 2,4,5-Trichlorophenol 5.1 1.0Not Detected

88-06-2 2,4,6-Trichlorophenol 4 1.0Not Detected

120-83-2 2,4-Dichlorophenol 10 1.0Not Detected

105-67-9 2,4-Dimethylphenol 5.1 1.0Not Detected

51-28-5 2,4-Dinitrophenol 25 1.0Not Detected

121-14-2 2,4-Dinitrotoluene 5.1 1.0Not Detected

606-20-2 2,6-Dinitrotoluene 5.1 1.0Not Detected

91-58-7 2-Chloronaphthalene 2 1.0Not Detected

95-57-8 2-Chlorophenol 10 1.0Not Detected

534-52-1 2-Methyl-4,6-dinitrophenol 20 1.0Not Detected

91-57-6 2-Methylnaphthalene 5.1 1.0Not Detected

95-48-7 2-Methylphenol (o-Cresol) 10 1.0Not Detected

88-74-4 2-Nitroaniline 20 1.0Not Detected

88-75-5 2-Nitrophenol 5.1 1.0Not Detected

108394,106445 3 & 4-Methylphenol 20 1.0Not Detected

99-09-2 3-Nitroaniline 20 1.0Not Detected

101-55-3 4-Bromophenyl phenyl ether 2 1.0Not Detected

59-50-7 4-Chloro-3-methyl-phenol 5.1 1.0Not Detected

7005-72-3 4-Chlorodiphenylether 1 1.0Not Detected

100-01-6 4-Nitroaniline 20 1.0Not Detected

100-02-7 4-Nitrophenol 25 1.0Not Detected

83-32-9 Acenaphthene 1 1.01.7

208-96-8 Acenaphthylene 1 1.0Not Detected

62-53-3 Aniline 4 1.0Not Detected

120-12-7 Anthracene 1 1.0Not Detected

103-33-3 Azobenzene 2 1.0Not Detected

56-55-3 Benzo[a]anthracene 1 1.0Not Detected

50-32-8 Benzo[a]pyrene 1 1.0Not Detected

205-99-2 Benzo[b]fluoranthene 1 1.0Not Detected

191-24-2 Benzo[g,h,i]perylene 51 1.0Not Detected

207-08-9 Benzo[k]fluoranthene 1 1.0Not Detected

100-51-6 Benzyl Alcohol 51 1.0Not Detected

111-91-1 Bis(2-chloroethoxy)methane 2 1.0Not Detected

111-44-4 Bis(2-chloroethyl)ether 1 1.0Not Detected

CAS# : Chemical Abstract Service Registry Number

RL : Reporting Limit

ND : Not Detected ug / L : microgram / liter (ppb) mg / L : milligram / liter (ppm) ug / Kg : microgram / kilogram (ppb) mg / Kg : milligram / kilogram (ppm)

Laboratory Contacts

Inorganic Unit Mgr: Sandy Gregg

Organic Unit Mgr: Carol Smith

Page 4 of 891200046Lab Work Order #:

P.O. Box 30270

Lansing, MI 48909

TEL: (517) 335-9800

FAX: (517) 335-9600

Sample Number: AB47458 WASTE (SOIL DRUM)

TCLP Base Neutral Acid Compounds

Compound

Date Tested:

RL

Analytical Method:

CAS #

8270 Analyst:

Qualifier

12/15/2009 SMH

Extraction Method: Extraction Date: 12/10/20093510 Qualifier:

Dilution FactorResult ug/L

108-60-1 Bis(2-chloroisopropyl)ether 1 1.0Not Detected

117-81-7 Bis(2-ethylhexyl)phthalate 5.1 1.0Not Detected

85-68-7 Butyl benzyl phthalate 5.1 1.0Not Detected

86-74-8 Carbazole 5.1 1.0Not Detected

218-01-9 Chrysene 1 1.0Not Detected

53-70-3 Dibenz[a,h]anthracene 52 1.0Not Detected

132-64-9 Dibenzofuran 4 1.0Not Detected

84-66-2 Diethylphthalate 5.1 1.0Not Detected

131-11-3 Dimethyl phthalate 5.1 1.0Not Detected

84-74-2 Di-n-butyl phthalate 5.1 1.0Not Detected

117-84-0 Di-n-octyl phthalate 5.1 1.0Not Detected

206-44-0 Fluoranthene 1 1.0Not Detected

86-73-7 Fluorene 1 1.01.1

118-74-1 Hexachlorobenzene 1 1.0Not Detected

87-68-3 Hexachlorobutadiene 1 1.0Not Detected

77-47-4 Hexachlorocyclopentadiene 5Z10 1.0Not Detected

67-72-1 Hexachloroethane 1 1.0Not Detected

193-39-5 Indeno(1,2,3-c,d)pyrene 2 1.0Not Detected

78-59-1 Isophorone 1 1.0Not Detected

91-20-3 Naphthalene 1 1.0Not Detected

98-95-3 Nitrobenzene 2 1.0Not Detected

67-75-9 N-Nitrosodimethylamine 5.1 1.0Not Detected

621-64-7 N-Nitrosodi-n-propylamine 2 1.0Not Detected

86-30-6 N-Nitrosodiphenylamine 2 1.0Not Detected

87-86-5 Pentachlorophenol 20 1.0Not Detected

85-01-8 Phenanthrene 1 1.0Not Detected

108-95-2 Phenol 5.1 1.0Not Detected

129-00-0 Pyrene 1 1.0Not Detected

110-86-1 Pyridine 20 1.0Not Detected

Probable petroleum product(s) present.

TCLP Pesticide Compounds

Compound

Date Tested:

RL

Analytical Method:

CAS #

8081 Analyst:

Qualifier

12/16/2009 MF

Extraction Method: Extraction Date: 12/08/20093510 Qualifier:

Dilution FactorResult ug/L

SURROGATE #Decachlorobiphenyl# 61.7

SURROGATE #Tetrachloro-m-xylene# 45.3

72-54-8 4,4'-DDD 0.03 1.0Not Detected

72-55-9 4,4'-DDE 0.02 1.0Not Detected

50-29-3 4,4'-DDT 0.05 1.0Not Detected

CAS# : Chemical Abstract Service Registry Number

RL : Reporting Limit

ND : Not Detected ug / L : microgram / liter (ppb) mg / L : milligram / liter (ppm) ug / Kg : microgram / kilogram (ppb) mg / Kg : milligram / kilogram (ppm)

Laboratory Contacts

Inorganic Unit Mgr: Sandy Gregg

Organic Unit Mgr: Carol Smith

Page 5 of 891200046Lab Work Order #:

P.O. Box 30270

Lansing, MI 48909

TEL: (517) 335-9800

FAX: (517) 335-9600

Sample Number: AB47458 WASTE (SOIL DRUM)

TCLP Pesticide Compounds

Compound

Date Tested:

RL

Analytical Method:

CAS #

8081 Analyst:

Qualifier

12/16/2009 MF

Extraction Method: Extraction Date: 12/08/20093510 Qualifier:

Dilution FactorResult ug/L

319-84-6 a-BHC 0.02 1.0Not Detected

5103-71-9 a-Chlordane 0.01 1.0Not Detected

309-00-2 Aldrin 0.01 1.0Not Detected

319-85-7 b-BHC 0.02 1.0Not Detected

319-86-8 d-BHC 0.02 1.0Not Detected

60-57-1 Dieldrin 0.02 1.0Not Detected

959-98-8 Endosulfan I 0.02 1.0Not Detected

33213-65-9 Endosulfan II 0.03 1.0Not Detected

1031-07-8 Endosulfan sulfate 0.05 1.0Not Detected

72-20-8 Endrin 0.02 1.0Not Detected

7421-93-4 Endrin aldehyde 0.02 1.0Not Detected

53494-70-5 Endrin ketone 0.02 1.0Not Detected

58-89-9 g-BHC (Lindane) 0.02 1.0Not Detected

5103-74-2 g-Chlordane 0.01 1.0Not Detected

76-44-8 Heptachlor 0.01 1.0Not Detected

1024-57-3 Heptachlor epoxide K0.02 1.0Not Detected

87-82-1 Hexabromobenzene 0.02 1.0Not Detected

72-43-5 Methoxychlor 0.05 1.0Not Detected

2385-85-5 Mirex 0.02 1.0Not Detected

59080-40-9 PBB (BP-6) 0.05 1.0Not Detected

8001-35-2 Toxaphene 0.1 1.0Not Detected

CAS# : Chemical Abstract Service Registry Number

RL : Reporting Limit

ND : Not Detected ug / L : microgram / liter (ppb) mg / L : milligram / liter (ppm) ug / Kg : microgram / kilogram (ppb) mg / Kg : milligram / kilogram (ppm)

Laboratory Contacts

Inorganic Unit Mgr: Sandy Gregg

Organic Unit Mgr: Carol Smith

Page 6 of 891200046Lab Work Order #:

P.O. Box 30270

Lansing, MI 48909

TEL: (517) 335-9800

FAX: (517) 335-9600

Sample Number: AB47458 WASTE (SOIL DRUM)

Date TestedAnalyte Name MethodCAS# QualifierResult AnalystRLUnit

7440-38-2 Arsenic - TCLP LAV706012/22/2009µg/LND 10

7782-49-2 Selenium - TCLP LAV774012/14/2009µg/LND 10

7440-22-4 Silver - TCLP LAV776112/10/2009µg/LND 5

Ignitability of Solids KS103001/13/2010FlammableNO

7439-97-6 Mercury - TCLP TS747012/18/2009µg/LND 0.4

Mercury Digestion - TCLP TS747012/17/2009Completed

7440-39-3 Barium - TCLP M 95 WN601012/14/2009µg/L620 10

7440-43-9 Cadmium - TCLP WN601012/14/2009µg/LND 20

7440-47-3 Chromium - TCLP WN601012/14/2009µg/LND 50

7440-50-8 Copper - TCLP WN601012/14/2009µg/LND 20

7439-92-1 Lead - TCLP WN601012/14/2009µg/LND 100

7440-66-6 Zinc - TCLP M 31 WN601012/14/2009µg/L130 20 pH - Sediment LU904512/18/2009pH8.22

Digestion - TCLP BB301012/11/2009Completed

Extraction - TCLP BB1131112/07/2009Completed

Extraction - TCLP Organics BB131112/07/2009Completed

Florisil Cleanup DT362012/15/2009Completed

Gel Permeation Cleanup DT364012/14/2009Completed

CAS# : Chemical Abstract Service Registry Number

RL : Reporting Limit

ND : Not Detected ug / L : microgram / liter (ppb) mg / L : milligram / liter (ppm) ug / Kg : microgram / kilogram (ppb) mg / Kg : milligram / kilogram (ppm)

Laboratory Contacts

Inorganic Unit Mgr: Sandy Gregg

Organic Unit Mgr: Carol Smith

Page 7 of 891200046Lab Work Order #:

P.O. Box 30270

Lansing, MI 48909

TEL: (517) 335-9800

FAX: (517) 335-9600

Qualifier DescriptionQualifier Code

1 Result(s) and RL(s) are estimated due to low surrogate recovery.

2 Result is estimated due to high surrogate recovery.

3 Result(s) and RL(s) are estimated due to low matrix spike recovery.

4 Result is estimated due to high matrix spike recovery.

5 Result and RL are estimated due to low continuing calibration standard criteria failure.

6 Result is estimated due to high continuing calibration standard criteria failure.

7 Result(s) and RL(s) are estimated due to poor precision.

8 Result(s) and RL(s) are estimated due to low recovery of batch QC.

9 Result outside QC acceptance criteria.

A Value reported is the mean of two or more determinations.

C Value calculated from other independent parameters.

D Analyte value quantified from a dilution(s); reporting limit (RL) raised.

E Result is estimated due to high recovery of batch QC.

F Amenable cyanide was not analyzed due to low level of total cyanide.

G Result and RL are estimated due to initial calibration standard criteria failure.

H Recommended laboratory holding time was exceeded.

I Dilution required due to matrix interference; reporting limit (RL) raised.

J Analyte was positively identified. Value is an estimate.

JA Result is estimated due to multiple Aroclors present.

JC Result is estimated since confirmation analysis did not meet acceptance criteria

JD Due to severe degradation, specific Aroclor identification is difficult and quantitation is estimated.

K RL(s) raised due to matrix interferences.

KR RL(s) raised due to low sample volume submitted.

KS RL(s) raised due to low total solids.

KW RL(s) raised due to light sample weight.

LB Reported library search compounds are tentative…