Pages 1-3 KRESA CTE TechnologyDrawings.pdf

PDF 2 MB Posted

Attached to
KALAMAZOO RESA CTE CENTER - TECHNOLOGY BID PACKAGE
Solicitation number
RFP - KRES - 240000000536
Issued by
Kalamazoo County, Port Hope Village, Michigan

About this file

The document is a set of drawings for the technology systems of the Kalamazoo Regional Educational Service Agency (KRESA) Career Connect Campus project. The drawings detail the specifications for security credential readers, controlled security schemes, emergency communication systems, paging speakers, information outlets, audio/visual equipment, video surveillance cameras, and other technology infrastructure required for the new facility. The project covers the first and second floors of the building, with technology systems divided into multiple areas serviced by different telecom rooms. Key dates, requirements, and responsibilities related to the technology installation are outlined.

The drawings specify pricing, installation, and coordination responsibilities between the technology contractor and other trades. Specific details on pricing terms, funding sources, and incumbent contractors are not provided. However, the documentation indicates this is a bid opportunity for the technology systems package of the larger KRESA Career Connect Campus project, which is located in Kalamazoo County, Michigan.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TECHNOLOGY SYMBOL LIST

SYMBOL: DESCRIPTION: NOTE:

EQUIPMENT

LIST ABBREV.:

3.SECURITY CREDENTIAL READER (WALL) TYPE 1AC-CR1-W

3.SECURITY CREDENTIAL READER (WALL) TYPE 2AC-CR2-W

3.SECURITY CREDENTIAL READER (WALL) TYPE 3AC-CR3-W

3.CONTROLLED SECURITY SCHEME SCHEDULE

IDENTIFIER

N/A

SECURITY EMERGENCY COMMUNICATION SYSTEM

MASTER STATION (WALL)

AR-ECM-W .

SECURITY DOOR LOCKDOWN DEVICE (CEILING)AC-LD-C .

CR1

CR2

CR3

CSS

LD

ECL

LD SECURITY DOOR LOCKDOWN DEVICE (WALL)AC-LD-W 3.

SECURITY EMERGENCY COMMUNICATION SYSTEM

LOBBY STATION (WALL)

AR-ECL-W .

ECM

.CLOCK (WALL) TYPE 1CC-C1-W

.CLOCK/SPEAKER (WALL) TYPE 5CC-CS1-W

C1

CS1

S1

S2

S1 FACILITY PAGING SPEAKER (CEILING) TYPE 1PA-S1-C

.FACILITY PAGING SPEAKER (CEILING) TYPE 2PA-S2-C

.FACILITY PAGING SPEAKER (WALL) TYPE 1PA-S1-W

1.INFORMATION OUTLET (CEILING)SC-IO-C

1.INFORMATION OUTLET (WALL)SC-IO-W

C#

C#

SC-IO-F

AV-FB-AV#

INFORMATION OUTLET AND AV DEVICE IN FLOOR

BOX/POKE THROUGH

5., 6.AV#

C#

4.

VIDEO SURVEILLANCE CAMERA 180° FOV

(CEILING/HORIZONTAL SURFACE)

VS-CM-#

4.

VIDEO SURVEILLANCE CAMERA 180° FOV

(WALL/VERTICAL SURFACE)

VS-CM-#

4.

VIDEO SURVEILLANCE CAMERA 270° FOV

(WALL/VERTICAL SURFACE)

VS-CM-#

4.

VIDEO SURVEILLANCE CAMERA 360° FOV

(CEILING/HORIZONTAL SURFACE)

VS-CM-#

4.

VIDEO SURVEILLANCE CAMERA DUAL LENS FOV

(CEILING/HORIZONTAL SURFACE)

VS-CM-#

4.

VIDEO SURVEILLANCE CAMERA SINGLE LENS FOV

(CEILING/HORIZONTAL SURFACE)

VS-CM-#

4.

VIDEO SURVEILLANCE CAMERA SINGLE LENS FOV

(WALL/VERTICAL SURFACE)

VS-CM-#

CM-#

CM-#

CM-#

CM-#

CM-#

CM-#

CM-#

S

S

M .AV MICROPHONE (CEILING/SURFACE)AV-MP#-C/S

.AV PERFORMANCE SPEAKER (CEILING)AV-SP#-C

.AV PERFORMANCE SPEAKER (WALL)AV-SP#-W

A .AV ANTENNA (WALL)AV-ANT#-W

A .AV ANTENNA (CEILING)AV-ANT-C

S .AV SOUND BAR (WALL)AV-SB#-W

ANT

.AV WALLPLATE/BACKBOX (WALL)AV-###-W

.AV CAMERA (CEILING)AV-CAM-#

.AV CAMERA (WALL)AV-CAM-#

T

T .AV TOUCH PANEL (SURFACE)AV-TP#-S

.AV TOUCH PANEL (WALL)AV-TP#-W

K AV KEYPAD (WALL)AV-KP#-W .

R .AV TOUCH PANEL (SURFACE)AV-RS#-W

ANT#

MP#

SP#

SP#

SB#

CAM-#

CAM-#

KP#

TP#

TP#

RS#

.AV PARTITION SENSORAV-PTS-WPTS

DB INTERCOM VIDEO DOOR BELL (WALL)IC-DB-W .

TECHNOLOGY ABBREVIATION KEY

ENTRANCE FACILITYEF-#

MAIN CROSS-CONNECTMC-#

TELECOMMUNICATIONS ROOMTR-#

ABOVE FINISHED FLOORAFF

BELOW FINISHED CEILINGBFC

CONDUITC

SIMILARSIM

TYPICALTYP

MOUNTING HEIGHT ABOVE FINISHED FLOOR+#

JUNCTION BOXJ-BOX

ABBR: DESCRIPTION:

UNLESS OTHERWISE NOTEDUON

FIELD OF VIEWFOV

DOUBLE POLE DOUBLE THROWDPDT

PAN TILT ZOOMPTZ

POWER OVER ETHERNETPOE

ABOVE FINISHED GRADEAFG

DELAYED EGRESSDE

TECHNOLOGY GENERAL NOTES:

1. ###-### INDICATES TECHNOLOGY EQUIPMENT SCHEDULE ITEM LABELED AS "EQUIPMENT

LIST ABBREVIATION"

2. REFER TO TECHNOLOGY EQUIPMENT SCHEDULE AND SPECIFICATIONS FOR FULL

DESCRIPTIONS AND MANUFACTURERS OF ALL DEVICES.

TECHNOLOGY MOUNTING SUBSCRIPT KEY:

A MOUNT AT +6" TO CENTERLINE ABOVE COUNTER OR BACKSPLASH

H MOUNT ORIENTED HORIZONTALLY

L MOUNT IN CASEWORK

M MOUNT IN MODULAR FURNITURE

S MOUNT IN SURFACE RACEWAY

A SLASH IS USED BETWEEN TWO SUBSCRIPTS, E.G., A/H.

1. THE LOCATION OF THE CONDUIT, HAND HOLES AND/OR MAINTENANCE HOLES SHOWN ARE

APPROXIMATE LOCATIONS. FIELD VERIFY THE LOCATION OF ALL UTILITIES PRIVATE AND/OR

PUBLIC PRIOR TO THE INSTALLATION OF THE COMPONENT. FIELD COORDINATE THE FINAL

LOCATION WITH THE OWNER AND ENGINEER PRIOR TO INSTALLATION.

2. POTHOLING TO LOCATE EXISTING UNDERGROUND UTILITIES, IF APPLICABLE, SHALL BE

INCLUDED IN THE CONTRACTOR'S BID. CONTRACTOR IS RESPONSIBLE FOR FINAL

PLACEMENT OF HAND HOLES AND/OR MAINTENANCE HOLES AND SHALL NOTIFY THE

ENGINEER OF FINAL LOCATIONS PRIOR TO INSTALLATION.

3. HAND HOLES AND/OR MAINTENANCE HOLES SHALL BE CONSTRUCTED SO THAT THE TOP OF

THE FRAME WILL BE FLUSH WITH THE GROUND LINE.

4. REMOVAL AND REPLACEMENT OF THE EXISTING UNDERGROUND UTILITIES THAT ARE

REQUIRED TO COMPLETE THE INSTALLATION SHALL BE INCLUDED IN THE CONTRACTOR'S

BID.

5. CONTRACTOR SHALL INCLUDE IN THEIR BID ANY REMOVAL AND REPLACEMENT OF EXISTING

SIDEWALK, PAVEMENT, GRASS, SHRUBS, TREES, ETC. THAT WILL BE IMPACTED BY THE

INSTALLATION OF THE NEW CONDUITS SHOWN ON THE DRAWINGS. IF TREES ARE REQUIRED

TO BE REMOVED THE CONTRACTOR SHALL CONTACT THE OWNER AND DISCUSS OPTIONS

PRIOR TO CUTTING DOWN ANY TREE OR SHRUB OVER 5' IN HEIGHT.

6. NO ADDITIONAL COST SHALL BE APPROVED FOR PLACING CONDUITS DEEPER THAN

REQUIRED MINIMUM DEPTH TO AVOID EXISTING UNDERGROUND UTILITIES.

7. PROVIDE A MINIMUM OF 25'-0" SLACK LOOP WITHIN EACH HAND HOLES AND/OR

MAINTENANCE HOLES. SLACK LOOP SHALL BE SECURE SO COPPER OR FIBER IS NOT

RESTING ON EARTH AFTER FINAL INSTALLATION.

TECHNOLOGY OUTSIDE PLANT NOTES

1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADA STANDARDS FOR

ACCESSIBLE DESIGN. REFER TO THE ADA GUIDELINES FOR ALL CONFIGURATION DETAILS

ON THIS PAGE FOR ADDITIONAL INFORMATION.

2. CONCEAL ALL CONDUIT IN WALLS, PARTITIONS, ABOVE CEILING, IN FLOOR SLAB, ETC.

UNLESS OTHERWISE INDICATED ON THE PLANS OR IN THE SPECIFICATIONS. CONDUIT IN

MECHANICAL ROOMS AND STORAGE ROOMS WITHOUT CEILINGS MAY BE EXPOSED ON

BUILDING STRUCTURE.

3. BOXES LOCATED ON OPPOSITE SIDES OF NON-RATED WALLS SHALL BE OFFSET A MINIMUM

OF 6" HORIZONTALLY. BOXES ON OPPOSITE SIDES OF FIRE RATED WALLS SHALL BE

OFFSET A MINIMUM OF 24" HORIZONTALLY. "THRU-THE-WALL" BOXES SHALL NOT BE

ALLOWED WITHOUT PRIOR WRITTEN APPROVAL OF THE ARCHITECT/ENGINEER.

4. VERIFY ALL FURNITURE, MODULAR FURNITURE, AND EQUIPMENT LOCATIONS WITH

ARCHITECTURAL PLANS, ELEVATIONS, AND REVIEWED SHOP DRAWINGS. PRIOR TO MAKING

THE ACTUAL TELECOMMUNICATIONS INSTALLATION, ADJUST OUTLETS OR CONNECTION

LOCATIONS TO ACCOMMODATE FURNITURE AND/OR EQUIPMENT.

5. TELECOMMUNICATIONS EQUIPMENT SHALL BE MOUNTED TO ALLOW ACCESS TO

ELECTRICAL AND MECHANICAL EQUIPMENT. ALL MOUNTING OF TELECOMMUNICATION

DEVICES ON EQUIPMENT SUPPLIED BY ANOTHER CONTRACTOR SHALL BE APPROVED IN

ADVANCE BY THE OTHER CONTRACTOR.

6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL

OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE

EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR

SEALED INTO OPENINGS.

7. ALL MATERIALS USED TO SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS SHALL

BE TESTED AND CERTIFIED AS A SYSTEM PER ASTM E814 STANDARDS FOR FIRE TESTS OF

THROUGH-PENETRATION FIRESTOPS. REFER TO 27 05 03 AND 28 05 03 FOR ADDITIONAL

INFORMATION AND REQUIREMENTS SPECIFIC TO FIRESTOPPING.

8. ALL LADDER RACK AND CABLE TRAY SIZES ARE AS DEFINED ON THE DRAWINGS. REFER TO

SPECIFICATION SECTIONS 27 05 28 AND 27 11 00 FOR APPROVED MANUFACTURERS AND

INSTALLATION REQUIREMENTS.

9. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO THE

WALLS, FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES

DAMAGE IS RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE

RATING, AND FINISH.

TECHNOLOGY INSTALLATION NOTES:

GENERAL NOTES:

1. ALL SYMBOLS AND ABBREVIATIONS LISTED MAY NOT BE APPLICABLE TO THIS PROJECT.

REFER TO THE GENERAL TECHNOLOGY EQUIPMENT SCHEDULE FOR MORE COMPLETE

DESCRIPTION AND ITEMS.

2. ALL SYMBOLS AND ABBREVIATIONS REFER TO TECHNOLOGY SHEETS ONLY AS DEFINED ON

THE SHEET INDEX. REFER TO THE TECHNOLOGY NOTES FOR ADDITIONAL INFORMATION.

3. ALL SYMBOLS LISTED ABOVE ARE FOR REFERENCE ONLY. REFER TO PLANS AND LINE TYPE

KEY FOR NEW, EXISTING TO REMAIN AND TO BE REMOVED ITEMS FOR ADDITIONAL

INFORMATION.

4. REFER TO RISERS ON SHEET(S): T3.4, T3.5, T3.6, T3.7, T3.8,T3.9,T3.10, T6.1, T6.2.

TECHNOLOGY SYMBOL NOTES:

1. "C#" INDICATES INFORMATION OUTLET FACEPLATE CONFIGURATION. REFER TO

INFORMATION OUTLET SCHEDULE ON T7.3 FOR ADDITIONAL INFORMATION.

2. SYMBOL SUBSCRIPT INDICATES DEVICE TYPE. REFER TO TECHNOLOGY EQUIPMENT

SCHEDULE ON T7.1 FOR ADDITIONAL INFORMATION.

3. REFER TO CONTROLLED SECURITY SCHEME (CSS) TYPE SCHEDULE ON T7.2 FOR

ADDITIONAL INFORMATION AND 1/T6.2 FOR DOOR ROUGH-IN INFORMATION.

4. "CM-#" ON FLOOR PLANS INDICATES CAMERA TYPE AND IS ASSOCIATED WITH THE

CORRESPONDING "VS-CM-#" EQUIPMENT SCHEDULE ABBREVIATION. "##-##" SUBSCRIPT

INDICATES FLOOR NUMBER-CAMERA NUMBER. REFER TO INDIVIDUAL CAMERA

REQUIREMENT SCHEDULE FOR ADDITIONAL INFORMATION.

5. INFORMATION OUTLET INSTALLED IN E.C. PROVIDED FLOOR BOX. "C#" INDICATES

INFORMATION OUTLET FACEPLATE CONFIGURATION. REFER TO INFORMATION OUTLET

SCHEDULE ON T7.3 FOR ADDITIONAL INFORMATION. REFER TO THE ELECTRICAL FLOOR

PLANS AND ELECTRICAL EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION.

6. AV INSTALLED IN E.C. PROVIDED FLOOR BOX. "AV#" INDICATES AV TYPE CONFIGURATION.

REFER TO TECHNOLOGY EQUIPMENT SCHEDULE ON T7.1 FOR ADDITIONAL INFORMATION.

REFER TO THE ELECTRICAL FLOOR PLANS FOR ADDITIONAL INFORMATION ON FLOOR BOX.

CABLE TRAY, CHANNEL TRAY, BASKET

TRAY

LADDER RACK

WIDTH X HEIGHT

WIDTH X HEIGHT

DIAMETERø C CONDUIT

CONDUIT DOWN

CONDUIT UP OR UP/DOWN

CONDUIT SLEEVE

CONTINUATION

PLAN OR DETAIL NUMBER

PLAN OR DETAIL NAME

PLAN OR DETAIL SCALE

DETAIL REFERRED TO BY SECTION CUT

SHEET DETAIL IS LOCATED

ON

NAME

VIEW NAME

1/8" = 1'-0"

M101

SIMSIM

INDICATES SIMILAR DETAIL REFERENCED

IN MULTIPLE LOCATIONS

LEVEL NAME

10'-0" HEIGHT ABOVE

PROJECT 0'-0"

1 INDICATES NOTE USED TO DESCRIBE

ADDITIONAL INFORMATION ABOUT

WORK REQUIRED, SPECIFIC TO THE

SHEET AND/OR DETAIL

N

O R HT

INDICATES DIRECTION OF TRUE NORTH

VIEW KEY

LINE TYPE AND TAG KEY:

NEW WORK BY THIS CONTRACTOR (WIDE LINE)

NEW

EXISTING TO BE REMOVED (SHORT DASHED PATTERN)

NEW UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN)

EXISTING TO REMAIN OR WORK BY OTHERS (NARROW LINE)

EXISTING

HALFTONING DOES NOT MODIFY SCOPE.

TAG-1 UNDERLINED TAG INDICATES OBJECT IS IN-SCOPE. IF NEW, ADDITIONAL

INFORMATION IS AVAILABLE IN A SCHEDULE, MATERIAL LIST, OR SYMBOL LIST

INDICATES AN EXISTING SYSTEM'S POINT OF CONNECTION/REMOVAL

T101

THE LINE TYPES SHOWN ARE FOR THE CONVENIENCE OF THE CONTRACTOR. THE CONTRACTOR

SHALL VERIFY RATINGS WITH THE LATEST SET OF ARCHITECTURAL PLANS AND FURNISH ALL

MATERIALS REQUIRED TO COMPLY WITH THOSE RATINGS WHETHER SHOWN OR NOT.

ALL FLOOR, FLOOR CEILING, AND ROOF CEILING ASSEMBLIES SHALL BE DESIGNATED AS 1 OR 2

HOUR FIRE/SMOKE BARRIERS, UNLESS NOTED OTHERWISE ON THE PLANS. RATINGS WERE

ACQUIRED FROM THE ARCHITECTURAL PLANS DATED 09/01/22.

FIRE / SMOKE BARRIER DESIGNATIONS

1 HOUR FIRE BARRIER

SMOKE PARTITION

2 HOUR FIRE BARRIER OR WALL

TEMPERATURE CONTROLS CONTRACTORT.C.C.

CIVIL CONTRACTORC.C.

FIRE PROTECTION CONTRACTORF.P.C.

PLUMBING CONTRACTORP.C.

MECHANICAL CONTRACTORM.C.

ELECTRICAL CONTRACTORE.C.

CONTRACTOR ABBREVIATION KEY

ABBR: DESCRIPTION:

TECHNOLOGY CONTRACTORT.C.

CONSTRUCTION MANAGERC.M.

FOOD SERVICE CONTRACTORF.S.C.

M

A X

20" MAX.

M

A X

20"-25" MAX.

M

A X

M

IN

. 4

M

A X

M

A X

10" MAX. 10"-24" MAX.

ADA GUIDELINES - FRONT ACCESS

ADA STANDARDS FOR ACCESSIBLE DESIGN

INSTALL ABOVE COUNTER

DEVICE AT 44" ABOVE

FINISHED FLOOR.

INSTALL ABOVE COUNTER

DEVICE AT 40" ABOVE

FINISHED FLOOR.

INSTALL DEVICE AT 18"

ABOVE FINISHED FLOOR.

ADA GUIDELINES - SIDE ACCESS

INSTALL DEVICE AT 44"

ABOVE FINISHED FLOOR.

INSTALL DEVICE AT 42"

ABOVE FINISHED FLOOR.

AV FUNCTIONAL DIAGRAM KEY

AV-***-###

HDMI (HDCP 2.X)

HDMI (HDCP 2.X)

USB TYPE-A (2.0)

USB TYPE-A (2.0)

SERIAL T.B. (RS-232)

RJ-45 (ETHERNET)

24VDC @ 1.0A

HDMI (HDCP 2.X)

INFRARED T.B. (IR)

RJ-45 (HDBASET)

EQUIPMENT TAG

INPUT

CONNECTION

OUTPUT

CONNECTION

0000 0000

SIGNAL CONNECTION ON

SAME SHEET - INPUT

SIGNAL CONNECTION ON

SAME SHEET - OUTPUT

0000 1/T000

SIGNAL CONNECTION ON

DIFFERENT SHEET - INPUT

SIGNAL CONNECTION ON

DIFFERENT SHEET - OUTPUT

1/T000 0000

TECHNOLOGY SHEET INDEX

T0.1 TECHNOLOGY COVERSHEET

T1.0 TECHNOLOGY SITE PLAN

T1.1 OVERALL FIRST FLOOR - TECHNOLOGY

T1.1A LEVEL 01 PLAN - TECHNOLOGY - AREA A

T1.1B LEVEL 01 PLAN - TECHNOLOGY - AREA B

T1.1C LEVEL 01 PLAN - TECHNOLOGY - AREA C

T1.1D LEVEL 01 PLAN - TECHNOLOGY - AREA D

T1.1E LEVEL 01 PLAN - TECHNOLOGY - AREA E

T1.1F LEVEL 01 PLAN - TECHNOLOGY - AREA F

T1.2 OVERALL SECOND FLOOR - TECHNOLOGY

T1.2A LEVEL 02 PLAN - TECHNOLOGY - AREA A

T1.2B LEVEL 02 PLAN - TECHNOLOGY - AREA B

T1.2C LEVEL 02 PLAN - TECHNOLOGY - AREA C

T1.2D LEVEL 02 PLAN - TECHNOLOGY - AREA D

T1.2E LEVEL 02 PLAN - TECHNOLOGY - AREA E

T1.2F LEVEL 02 PLAN - TECHNOLOGY - AREA F

T2.1A LEVEL 01 PLAN - AV - AREA A

T2.1B LEVEL 01 PLAN - AV - AREA B

T2.1C LEVEL 01 PLAN - AV - AREA C

T2.1D LEVEL 01 PLAN - AV - AREA D

T2.1E LEVEL 01 PLAN - AV - AREA E

T2.1F LEVEL 01 PLAN - AV - AREA F

T2.2A LEVEL 02 PLAN - AV - AREA A

T2.2B LEVEL 02 PLAN - AV - AREA B

T2.2C LEVEL 02 PLAN - AV - AREA C

T2.2D LEVEL 02 PLAN - AV - AREA D

T2.2E LEVEL 02 PLAN - AV - AREA E

T2.2F LEVEL 02 PLAN - AV - AREA F

T3.1 TECHNOLOGY ENLARGEMENTS

T3.2 TECHNOLOGY ENLARGEMENTS

T3.3 TECHNOLOGY ENLARGEMENTS

T3.4 TECHNOLOGY RISERS

T3.5 TECHNOLOGY RISERS

T3.6 TECHNOLOGY RISERS

T3.7 TECHNOLOGY RISERS

T3.8 TECHNOLOGY RISERS

T3.9 TECHNOLOGY RISERS

T3.10 TECHNOLOGY RISERS

T6.1 TECHNOLOGY DETAILS

T6.2 TECHNOLOGY DETAILS

T6.3 TECHNOLOGY DETAILS

T7.1 TECHNOLOGY SCHEDULES

T7.2 TECHNOLOGY SCHEDULES

T7.3 TECHNOLOGY SCHEDULES

T7.4 TECHNOLOGY SCHEDULES

GRAND TOTAL: 45

SUGGESTED MATRIX OF RESPONSIBILITY

ITEM: SHOWN ON:

FURNISHED

BY:

INSTALLED

BY: NOTES:

TECHNOLOGY ROUGH-IN, REFER TO

TECHNOLOGY EQUIPMENT SCHEDULE

AND SPECIFICATIONS FOR DEFINITION

T-SERIES E.C. E.C. 3. 4.

INFORMATION OUTLET FACEPLATES,

JACKS, AND TERMINATIONS

T-SERIES T.C. T.C.

CONDUIT SLEEVES (WHEN SHOWN ON

DRAWINGS)

T-SERIES E.C. E.C.

CONDUIT SLEEVES (NOT SHOWN BUT

REQUIRED FOR PROPER INSTALLATION

OF SYSTEM)

N/A T.C. T.C. 2. 4.

TELECOMMUNICATION SYSTEMS

ROUGH-IN

T-SERIES T.C. E.C. 1.

TELECOMMUNICATION EQUIPMENT,

CABLING, AND TERMINATIONS

T-SERIES T.C. T.C.

CABLE TRAY (INCLUDING WIRE BASKET

TRAY) REFER TO SPECIFICATION

SECTION 27 05 28 FOR DEFINITION

T-SERIES E.C. E.C.

LADDER RACK T-SERIES T.C. T.C. 5.

GROUNDING LUGS ON TECHNOLOGY

EQUIPMENT

T-SERIES T.C. E.C. 6.

BONDING SYSTEM FOR TECHNOLOGY

SYSTEM, REFER TO SPECIFICATION

SECTION 27 05 26 FOR DEFINITION

T-SERIES E.C. E.C. 7. 8.

CONNECTION OF TECHNOLOGY

BONDING SYSTEM TO THE ELECTRICAL

GROUND SYSTEM

T-SERIES E.C. E.C.

LINE VOLTAGE POWER (+120V OR

GREATER)

E-SERIES E.C. E.C.

LINE VOLTAGE POWER (NOT SHOWN

BUT REQUIRED FOR PROPER

INSTALLATION OF SYSTEM)

N/A T.C. E.C. 2. 4.

LINE VOLTAGE POWER FOR DOOR

HARDWARE POWER SUPPLIES

ARCH SPEC E.C. E.C.

LOW VOLTAGE CABLING FOR

TECHNOLOGY SYSTEMS

T-SERIES T.C. T.C.

CABLE HANGERS AND SUPPORTS OR

OTHER CABLE ROUTING METHODS

(OTHER THAN CONDUIT AND CABLE

TRAY)

T-SERIES T.C. T.C. 5.

TECHNOLOGY SERVICE ENTRANCE

CONDUITS, HANDHOLES, AND

MANHOLES

E-SERIES E.C. E.C.

FLOOR BOX (ROUGH-IN) T & E SERIES E.C. E.C.

SUGGESTED MATRIX OF RESPONSIBILITY NOTES

1. LOCATIONS OF TELECOMMUNICATIONS ROUGH-INS SHALL BE INDICATED BY THE INFORMATION

OUTLET SYMBOLS ON THE DRAWINGS. REFER TO THE TECHNOLOGY SYMBOL LIST FOR

ADDITIONAL INFORMATION.

2. BASED ON THE INHERENT DIFFERENCES IN PRODUCTS FROM VARIOUS MANUFACTURERS, ALL

REQUIRED EQUIPMENT MAY NOT BE SHOWN ON THE DRAWINGS FOR ALL ACCEPTABLE

MANUFACTURERS.

3. INCLUDES BACKBOXES AND CONDUIT REQUIRED FOR THE TECHNOLOGY SYSTEMS

INSTALLATION. THE E.C. SHALL BASE THE BID ON THE BASIS OF DESIGN SHOWN ON THE

CONTRACT DOCUMENTS.

4. ALL CHANGES TO THE SLEEVES, BACKBOXES, CONDUITS, AND POWER REQUIRED BECAUSE OF

THE T.C.'S SELECTION OF AN ALTERNATE ACCEPTABLE MANUFACTURER OR FROM SYSTEM

CONFIGURATIONS THAT ARE LEFT TO THE CHOICE OF THE CONTRACTOR SHALL BE INCLUDED

IN THE T.C.'S BID. THIS BID SHALL INCLUDE INSTALLATION BY A LICENSED ELECTRICIAN.

5. UNLESS TRADE RULES DICTATE OTHERWISE.

6. FURNISHED AS PART OF THE EQUIPMENT WHEN POSSIBLE, OR FURNISHED TO THE E.C. FOR

INSTALLATION IN THE FIELD.

7. INCLUDES ALL CONDUCTORS, GROUND BARS, AND TERMINATIONS FOR THE COMPLETE

BONDING SYSTEM REQUIRED BY THE SPECIFICATIONS.

8. REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF PANELS AND SWITCHBOARDS SHOWN

IN THE TECHNOLOGY BONDING RISER DIAGRAM AND TYPICAL TELECOM ROOM BONDING FLOW

DIAGRAM.

TELECOM ROOM REFERENCES

TELECOM ROOM

DETAIL / SHEET

REFERENCE

FLOOR PLAN

REFERENCE ARCH ROOM NUMBER

MC-1 4/T3.2 T-1.1C C106A

TR-2C 7/T3.3 T-1.2C C200B

TR-A 1/T3.1 T-1.1A A103D

TR-B 4/T3.1 T-1.1B B104B

TR-C 1/T3.2 T-1.1C C100A

TR-D 1/T3.3 T-1.1D D104A

TR-E 4/T3.3 T-1.1E E110L

A B C D E F

DATE:

SCALE:

THE REPRODUCTION, COPYING OR

OTHER USE OF THIS DRAWING WITHOUT

WRITTEN CONSENT IS PROHIBITED.

© 2022 WIGHTMAN & ASSOCIATES, INC.

JOB NO:

REVISIONS

PROJECT NAME:

269.927.0100

269.327.3532

269.673.8465 www.gowightman.com

WIGHTMAN

BENTON HARBOR

KALAMAZOO

ALLEGAN

248.791.1371

ROYAL OAK

D

LR

G ro up

263 SHUMAN BOULEVARD,

SUITE 550

NAPERVILLE, IL 60563

W E

S T

W A

C K

E R

D R

IV

E

, S U

IT

E

C H

IC

A

G O

, I L w w w .d lr g ro u p .c o m

2.

0.

www.imegcorp.com 630.527.2320

As indicated

BIM 360://24-21104-00 KRESA Programming & Concepts/MEPT20_21007746.00_KRESA CTE Building_C.rvt

11/29/2023 8:15:07 PM

TECHNOLOGY

COVERSHEET

T0.1

11/20/2023

3500 VANRICK DRIVE

KALAMAZOO, MI 49001

KALAMAZOO

RESA

CAREER

CONNECT

CAMPUS

214175

1819 EAST MILHAM ROAD

PORTAGE, MI 49002

REFERENCE SCALE IN INCHES

0 1 2 3

PROJECT #

Illinois Design Firm Registration #184007637-0014

IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS

DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE

THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR

REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP. © 2022 IMEG CORP.

263 SHUMAN BOULEVARD, SUITE 550

NAPERVILLE, IL 60563

630.527.2320 FAX: 630.527.2321

www.imegcorp.com

21007746.00

ISSUED FOR BID 12/20/2022

1 ADDENDUM #03 01/18/2023

ISSUED FOR PLAN REVIEW 01/27/2023

2 BULLETIN #07 04/24/2023

ERATE 11/20/2023

3 TECHNOLOGY BIDS 11/29/2023

4 BULLETIN 17 11/29/2023

M DD

M DD

M GATE POST BENT

M GATE POST BENT

M GATE POST

M DD

M DD

M MET ER TRB?

M1 . CRB M1

M1 =

M W OOD POST

M OUT LET

M OUT LET

M1 . ERB

M1

M1 =

M1 . ERB

M1

M1 =

M1 . ERB

M1 M1 =

M PIPE 3I N DIAMET ER IRON

M EMT

M1 . ERB

M1M1 =

M GM

M POST METAL

M BB HOTEL 36I N DIAMET ER METAL BASE

M METAL POST

M METAL POST

M1 . GATE

M1 /

M VALVE PI PE

M VALVE PI PE

M2 . BB FOUNDATI ON

M2

M2 +

M W OOD POST

M1 . GATE

M3 . GATE M3 /

M1 /

M ELEC WIRE

M ELEC WIRE

853.882

853.824

853.382

853. 317

853. 216

853. 125

853. 018

851. 457

851. 709

851. 788

851. 999

852.535

855. 413855.439

853. 341 853.340

853. 231

853. 381

853.332

853. 163

853.237

853.244 853.233

853.042

853.478

853. 691

853.722853.703

853.303

848.774

848.746

848. 816

848.554

850.279

850.963

852.547

852.504

850. 781

850.797

850.809

848.472

842. 401

844. 151 844.307

841. 806

846.847

846.849

101156

850.522

DD A T B C

101159

850.580

DD A T B C

100071

100072

100089

100090

100091

1001 27

1001 28

1001 60

100220 100221

100222

100224

100267100268

100590 100591

100592

100593

100594

100595

100596

100597 100598

100599

100631

100634

100635100636

100654

100852

100853

100854

100855

100950

100951

101004

101005

101305

101306

101309

101356

101609

101661 101664

101679

300200

300201

MC-1

4 5

6 2

7 2

7 2

CM6

EXT-01

CM-6 2

CM-6 2

KEY PLAN

A

B

D

C

A B C D E F

DATE:

SCALE:

THE REPRODUCTION, COPYING OR

OTHER USE OF THIS DRAWING WITHOUT

WRITTEN CONSENT IS PROHIBITED.

© 2022 WIGHTMAN & ASSOCIATES, INC.

JOB NO:

REVISIONS

PROJECT NAME:

269.927.0100

269.327.3532

269.673.8465 www.gowightman.com

WIGHTMAN

BENTON HARBOR

KALAMAZOO

ALLEGAN

248.791.1371

ROYAL OAK

D

LR

G ro up

263 SHUMAN BOULEVARD,

SUITE 550

NAPERVILLE, IL 60563

W E

S T

W A

C K

E R

D R

IV

E

, S U

IT

E

C H

IC

A

G O

, I L w w w .d lr g ro u p .c o m

2.

0.

www.imegcorp.com 630.527.2320

E

F

1" = 40'-0"

BIM 360://24-21104-00 KRESA Programming & Concepts/MEPT20_21007746.00_KRESA CTE Building_C.rvt

11/29/2023 8:15:12 PM

TECHNOLOGY SITE

PLAN

T1.0

11/20/2023

3500 VANRICK DRIVE

KALAMAZOO, MI 49001

KALAMAZOO

RESA

CAREER

CONNECT

CAMPUS

214175

1819 EAST MILHAM ROAD

PORTAGE, MI 49002

N O R

HT

1" = 40'-0"

TECHNOLOGY SITE PLAN

GENERAL NOTES:

1. REFER TO ELECTRICAL SITE PLAN FOR LOW VOLTAGE UTILITY CONDUIT

REQUIREMENTS.

KEY NOTES:

1. PROVIDE INFORMATION OUTLET AND FIBER OPTIC TO COPPER MEDIA

CONVERTER FOR EMERGENCY PHONE. COORDINATE WITH ELECTRICAL

FOR 120V CONNECTION TO MEDIA CONVERTER. EMERGENCY PHONES ARE

OWNER PROVIDED, CONTRACTOR INSTALLED.

2. STUB-UP CONDUIT 3 INCHES INTO TELECOM ROOM MC-1.

3. (2) 1" UNDERGROUND CONDUITS. STUB-UP AND CAP CONDUIT WHERE

SHOWN FOR FUTURE EMERGENCY PHONE.

4. PROVIDE (2) 4" CONDUITS FROM EACH HANDHOLE TO MC-1 FOR FUTURE

CABLING BY UTILITY OR OWNER. (6) 4" CONDUITS TOTAL.

5. PROVIDE HANDHOLES FOR LOW VOLTAGE UTILITIES. FIBER, COPPER, AND

FUTURE OWNER PROVIDED FIBER FROM DATA CENTER. MINIMUM

HANDHOLE SIZE SHALL BE 36"x36"x36".

6. LIGHT POLE MOUNTED SECURITY CAMERA. PROVIDE 2-STRAND FIBER OPTIC

CABLE WITH FIBER OPTIC TO COPPER MEDIA CONVERTER. 120V BY

ELECTRICAL. REFER TO THE ELECTRICAL SITE PLAN FOR ADDITIONAL

INFORMATION. THE T.C. SHALL COORDINATE WITH THE E.C. ON STUB UP

LOCATION IN THE BUILDING FOR ROUTING FIBER TO THE NEAREST TR ROOM

SERVING THE SPACE.

7. CAMERA SHOWN FOR REFERENCE ONLY ON OVERALL EXTERIOR CAMERA

COVERAGE. REFER TO THE FLOOR PLAN FOR ADDITIONAL INFORMATION

REFERENCE SCALE IN INCHES

0 1 2 3

PROJECT #

Illinois Design Firm Registration #184007637-0014

IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS

DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE

THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR

REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP. © 2022 IMEG CORP.

263 SHUMAN BOULEVARD, SUITE 550

NAPERVILLE, IL 60563

630.527.2320 FAX: 630.527.2321

www.imegcorp.com

21007746.00

ISSUED FOR BID 12/20/2022

ISSUED FOR PLAN REVIEW 01/27/2023

ERATE 11/20/2023

1 TECHNOLOGY BIDS 11/29/2023

2 BULLETIN 17 11/29/2023

DN

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

A

B

C

D

3231302926

BB

AA

X

V

U

19 20 23 24

JJ

HH

GG

DD

E

F

G

I

L

O

P

Q

T

S

EE

M

J

Z

H

CC

II

R

W

Y

FF

N

N

HEAVY EQUIPMENT / INDUSTRIAL

B100B

INSTRUCTIONAL STUDIO

B101

INSTRUCTIONAL STUDIO

B102

AUTO GALLERY

B100

RESTROOM

B103B

STAIR 2

S102

IT COMPUTER SYSTEMS

C100

ADVANCED MANUFACTURING

C101

WELDING

C102

STORAGE

C102A

QAQC

C103

RESTROOM

C105B

URBAN FARM TO TABLE

E112

MECH

E108

CONSTRUCTION TRADES

D109

STORAGE

D110A

PLUMBING

D110

INSTRUCTIONAL STUDIO

D110C

STORAGE

D111A

STORAGE

D110B CULINARY LAB 1

D101

RECEIVING

D105

ELEC

D111

BOILER

B104

COMMONS

CR100MAINTENANCE WORKSHOP

D106

TOOL CRIB

B100C

MECH

C107

WAITING

A104

STAFF LOUNGE

A102

RESTROOM

E109A

TRANSPORTATION OFFICE

A100C

SRO

A100A

RECEPTION

A101

VESTIBULE

A000

DRY GOODS

D101A

INSTRUCTIONAL STUDIO

E106

EXOTICS

E100C

DRY STORAGE

E100D

KENNELS 1

E100K

BIO WASTE

E100H

STORAGE

E100G

CAT HOLDING

E100E

GROOMING

E101

EXAM

E102A

EXAM

E102B

ISOLATION

E102E

PHARMACY

E102D

X-RAY

E102C

JANITOR

E100F

SURGICAL

E102F

INSTRUCTIONAL STUDIO

E105 INDOOR PLAY

E100B

KENNELS 2

E100I

VESTIBULE

E100J

PREP

E102

SIMULATED RESTAURANT

C104

CAFE

D100A

OUTDOOR SEATING

C104A

VET CLINIC

E100

STORAGE

C100B

CORRIDOR

CR101

IDF

C100A

TOOL CRIB

C101B

AUTO-TECH

B100A

RESTROOM

D103B

RESTROOM

D103A

STORAGE

E105A

STORAGE

E103A

RESTROOM

E109C

JAN

F109B

RESTROOM

B103D

JAN

B103C

RESTROOM

C105A

ELECTRICAL

C107A

GENERATOR DISTRIBUTION ROOM

C107B

ELECTRICAL

B104A

ELECTRICAL

E100M

MDF

C106A

IDF

E100L

IDF

B104B

ELECTRICAL

D105A

IDF

D104A

LARGE CONFERENCE

E104

STAFF RESTROOM

E107BSTAFF RESTROOM

E107A

MOTHERS ROOM

C105D

STAFF RESTROOM

C105ESTAFF RESTROOM

C105F

STAFF RESTROOM

B103E

HVAC

D108

LOBBY

A002

CORRIDOR

C106

STAIR 1

S101

STAIR 3

S103

CORRIDOR

D104

MEDIUM CONFERENCE

F110

CIRCULATION

D107

CAFE KITCHEN

D100

CORRIDOR

B103

OFFICE

D105B

CORRIDOR

E100A

CORRIDOR

D103

STAIR 6

S106

AG LAB

E111

EVENT STORAGE

F110A

STAFF RESTROOM

A103A

STAFF RESTROOM

A103B

STUDENT WELLNESS

A104A

CONF

A104G

COUNSELOR OFFICE

A104F

COUNSELOR OFFICE

A104E

COUNSELOR OFFICE

A104D

COUNSELOR OFFICE

A104C

STOR.

A104B

FREEZER

D102A

COOLER

D102B

CULINARY LAB 2

D102

CORRIDOR

A100

CORRIDOR

C105

TECHNOLOGY WORKSHOP

B103A

ELEVATOR

EL101

KITCHEN

D102C

PHONE ROOM

A103C

STOR

C105C

JAN

C108

STOR

E111A

IT

A103D

ADMIN

A103

INSTRUCTIONAL STUDIO

E103

SMALL CONFERENCE

F107C

CORRIDOR

CR103

STAIR 5

S105

STAIR 4

S104

ELEVATOR

EL102

TRANSFORMER YARD

C107E

T3.3

TR-D

T3.2

TR-C

T3.2

MC-1

T3.1

TR-A

T3.3

TR-E

TR-B

T3.1

TECHNOLOGY DEVICES IN THIS

AREA ARE SERVED FROM

TELECOM ROOM TR-D

TECHNOLOGY DEVICES IN THIS

AREA ARE SERVED FROM

TELECOM ROOM TR-E

TECHNOLOGY DEVICES IN THIS

AREA ARE SERVED FROM

TELECOM ROOM TR-A

TECHNOLOGY DEVICES IN THIS

AREA ARE SERVED FROM

TELECOM ROOM TR-E

TECHNOLOGY DEVICES IN THIS

AREA ARE SERVED FROM

TELECOM ROOM TR-A

TECHNOLOGY DEVICES IN THIS

AREA ARE SERVED FROM

TELECOM ROOM TR-B

TECHNOLOGY DEVICES IN THIS

AREA ARE SERVED FROM

TELECOM ROOM TR-B

TECHNOLOGY DEVICES IN THIS

AREA ARE SERVED FROM

TELECOM ROOM MC-1

TECHNOLOGY DEVICES IN THIS

AREA ARE SERVED FROM

TELECOM ROOM MC-1

TECHNOLOGY DEVICES IN THIS

AREA ARE SERVED FROM

TELECOM ROOM TR-D

SC-LR-1

(TYP.)

KEY PLAN

A

B

D

C

A B C D E F

DATE:

SCALE:

THE REPRODUCTION, COPYING OR

OTHER USE OF THIS DRAWING WITHOUT

WRITTEN CONSENT IS PROHIBITED.

© 2022 WIGHTMAN & ASSOCIATES, INC.

JOB NO:

REVISIONS

PROJECT NAME:

269.927.0100

269.327.3532

269.673.8465 www.gowightman.com

WIGHTMAN

BENTON HARBOR

KALAMAZOO

ALLEGAN

248.791.1371

ROYAL OAK

D

LR

G ro up

263 SHUMAN BOULEVARD,

SUITE 550

NAPERVILLE, IL 60563

W E

S T

W A

C K

E R

D R

IV

E

, S U

IT

E

C H

IC

A

G O

, I L w w w .d lr g ro u p .c o m

2.

0.

www.imegcorp.com 630.527.2320

E

F

3/64" = 1'-0"

BIM 360://24-21104-00 KRESA Programming & Concepts/MEPT20_21007746.00_KRESA CTE Building_C.rvt

11/29/2023 8:15:38 PM

OVERALL FIRST

FLOOR -

TECHNOLOGY

T1.1

11/20/2023

3500 VANRICK DRIVE

KALAMAZOO, MI 49001

KALAMAZOO

RESA

CAREER

CONNECT

CAMPUS

214175

1819 EAST MILHAM ROAD

PORTAGE, MI 49002

N O R

HT

3/64" = 1'-0"

FIRST FLOOR - TECHNOLOGY

KEY NOTES:

1. TELECOM ROOM TR-C IS DEDICATED TO THE

IT COMPUTER SYSTEMS ROOM FOR TRAINING

PURPOSES AND DOES NOT SERVE

INFORMATION OUTLETS OUTSIDE OF THE

CLASSROOM.

REFERENCE SCALE IN INCHES

0 1 2 3

PROJECT #

Illinois Design Firm Registration #184007637-0014

IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS

DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE

THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR

REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP. © 2022 IMEG CORP.

263 SHUMAN BOULEVARD, SUITE 550

NAPERVILLE, IL 60563

630.527.2320 FAX: 630.527.2321

www.imegcorp.com

21007746.00

GENERAL NOTES:

1. PROVIDE (4) 4" CONDUITS UP TO ACCESSIBLE

CEILING SPACE AT SECOND FLOOR FOR EACH

TELECOM ROOM FOR SECOND FLOOR

HORIZONTAL CABLING. COORDINATE EXACT

LOCATION WITH ARCHITECT.

ISSUED FOR BID 12/20/2022

ISSUED FOR PLAN REVIEW 01/27/2023

ERATE 11/20/2023

1 TECHNOLOGY BIDS 11/29/2023

2 BULLETIN 17 11/29/2023

File details come from the government source that posted it. Updated .