About this file

This single source justification document outlines proprietary products and services required for a project to replace damaged doors and upgrade a card access system at a Department of Veterans Affairs medical center. Specifically, the project requires Corbin Russwin door hardware, Kaba Peaks lock cylinders, and components for an existing General Electric/EST-3 fire alarm system from the original manufacturer and installer, Signet Electronic Systems. It will also involve work with the medical center's existing Hirsch Electronics card access system, which covers multiple divisions across the entire complex. The justification cites the proprietary nature and compatibility needs for existing standardized and integrated systems as reasons only these manufacturers' products can meet requirements. The estimated value is $80,000. The contracting officer certified the single source procurement is in accordance with FAR.

View the file

Other files for this federal contract opportunity

Other files attached to Z1DA--Replace Damaged Doors and Upgrade Card System WR, newest first.
File Type Posted
523A4-12-207 Site Walk 1-10-24.pdf PDF
36C24123R0181 0004.docx DOCX document
Appendix A- VAMC Door List RFI 5.pdf PDF
Replace Damaged Doors RFI Answers 1-8.docx DOCX document
S02 - MA WD 01-19-24.txt TXT text file
36C24123R0181 0003.docx DOCX document
36C24123R0181 0002.docx DOCX document
S02 - 523A4-12-207 Drawings.pdf PDF
36C24123R0181 0001.docx DOCX document
S02 - Lead Report Map.pdf PDF
S02 - Damaged Door ICRA.pdf PDF
S02 Past Performance Questionnaire.docx DOCX document
S02 - Itemized Price Breakdown.xlsx XLSX spreadsheet
S02 - W Roxbury - Volume 1 - FINAL.pdf PDF
S02 - VAMC Doors PACS work narrative.pdf PDF
S02 - Revised Specifications.pdf PDF
S02 - SOW.docx DOCX document
36C24123R0181 RFP.docx DOCX document
S02 - MA WD 12-8-2023.txt TXT text file
S02 - Damaged Doors PCRA.pdf PDF
S02 - Survey Report W Roxbury Bldg 01.pdf PDF
Show all 21

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VHAPG Part 813.106 Simplified Acquisition Procedures: Soliciting from a Single Source Attachment 1: Single Source Justification for SAP under the SAT

Last Updated: 02/01/22 Page 1 of 2

DEPARTMENT OF VETERANS AFFAIRS

Justification for Single Source Awards IAW FAR 13.106-1

For Over Micro-Purchase Threshold but Not Exceeding the SAT ($250K)

Acquisition Plan Action ID: 36C241-23-AP-4839

1. Contracting Activity: Department of Veterans Affairs, VISN1, VHA West Roxbury Healthcare System, West

Roxbury, MA; NCO1 Contracting and Engineering

2. Brief Description of Supplies/ Services required and the intended use/Estimated Amount:

Select proprietary products to be used on 523A4-12-207; Replace Damaged Doors and Upgrade Card Access System. The sole source proprietary products are:

a) Door Hardware – Corbin Russwin.

b) Door Lock Cylinders with Removable Cores - Kaba Peaks 6-pin LFIC. VA West Roxbury Engineering

Building Standard for Keyed Security System.

c) Fire Alarm System including components: General Electric/EST-3 Fire Alarm System as assembled and bench tested by the manufacturer of record, Signet Electronic Systems, Inc. This system is VA West Roxbury’s Engineering’s Building Standard for the Fire Alarm System.

d) Electronic Safety & Security- Hirsh Electronics, Signet Electronic Systems, Electronic security installation requirements for Hirsch Electronics Card Access System is the sole manufacturer and Signet Electronic Systems is the local representative.

Estimated Value: $80,000

3. Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used:

a) Corbin Russwin Door Hardware – Corbin Russwin is the existing VA West Roxbury Engineering building standard for door locks that is installed and operating campus wide at the West Roxbury VAMC. Corbin Russwin products are compatible with the Kaba Peaks keying system used on the West Roxbury VAMC campus; other manufacturer’s door locks may not be compatible with the Kaba Peaks keying system and may not operate properly or operate at all with the Kaba Peaks keying system. The West Roxbury campus has an existing locksmith with inventory of Corbin Russwin door locks and spare parts; it would be uneconomical for VA locksmith to create additional inventories of other manufacturer’s door locks.

Therefore, only this manufacturer’s products are acceptable; no substitutions.

b) Kaba Peaks Lock Cylinders with Removable Cores – Kaba Peaks Lock Cylinders with Removable Cores is the existing VA West Roxbury Engineering building standard for door lock cylinders that is installed and operating for the keyed security system campus wide at the West Roxbury VAMC. Other manufacturer’s cannot make the Kaba Peaks lock cylinder and would not be compatible with the existing keyed security system. The West Roxbury campus has an existing locksmith with inventory of 6-pin LFIC; in order for the new door lock cylinders with removable cores on this project be coordinated with the existing locksmith and inventory, the door lock cylinders with removable cores must be Kaba Peaks 6-pin LFIC door lock cylinders with removable cores. Therefore, only this manufacturer’s products are acceptable; no substitutions.

c) General Electric/EST-3 Fire Alarm System as assemble and bench tested by the manufacturer of record, Signet Electronic Systems, Inc.: General Electric/EST-3 Fire Alarm System as assembled and bench tested by the manufacturer of record (Signet Electronic Systems, Inc.) is the existing fire alarm system installed https://www.acquisition.gov/?q=/browse/far/13

VHAPG Part 813.106 Simplified Acquisition Procedures: Soliciting from a Single Source Attachment 1: Single Source Justification for SAP under the SAT

Last Updated: 02/01/22 Page 2 of 2 and operating campus wide at the West Roxbury VAMC. National Fire Protection Association (NFPA), Building Code, Life Safety Code and VA Standard require Fire Alarm systems to be the product of one manufacturer to maintain UL listing, NFPA compliance testing and hospital certification. This project will include fire alarm system installation that is an extension of the existing campus wide code compliant and certified fire alarm system. Any products to be used on the existing fire alarm system must be the existing system’s products In order to ensure system compatibility and to maintain manufacturer’s warranty;

other manufacturer’s components may not operate properly or operate at all on the existing system.

Therefore, only this manufacturer’s products are acceptable; no substitutions.

d) Electronic Safety & Security – The entire Medical Center Complex (all three divisions) is on a Hirsch Electronic card access system. The system provides security to the complex and is connects directly to monitors in the Police headquarters at all three divisions. The nodes of the system are in controlled spaces throughout the facility, access to the spaces is strictly controlled to assure the security of this system and other critical information systems in these spaces. The system as a whole, over $3,500,000 of installed equipment, is an essential part of assuring Safety & Security of patients and staff at the Medical Center with monitoring capabilities. Accordingly as we look toward adding small new pieces to the system it is essential that we safeguard our investment and the systems overall integrity. The recommended source has demonstrated both the ability to install the system properly and to troubleshoot problems when they occur. The workmen have shown that they are reliable and can be trusted. This is essential because of the spaces they will be working in. No other contractor has the information, nor does the VA have an adequate inventory and description in order to allow other to provide proposals. Moreover, if another contractor performed work on the system and the VA had problems after the fact with the system, the government could certainly end up in a dispute not easily resolvable as each vendor could blame the other for the problems with the system and the VA, even with the devotion of a lot of time, would be hard pressed to determine who was at fault. Engineering Service believes that a critical system like this one needs to be taken care of and modified by a single company so that when there are problems a single course can be contacted for immediate correction.

4. Description of market research conducted and results or statement why it was not conducted:

Market Research was not conducted in association with this request. The reason is that the products and services to be sole sourced were previously obtained through full and open competition procedures and are now integral parts of existing facility systems.

5. Contracting Officer's Certification: Purchase is approved in accordance with FAR13.106-1(b). I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief.

Name Date Title https://acquisition.gov/far/current/html/Subpart%2013_1.html#wp1125466

2023-11-30T15:05:54-0500
MICHAEL MULLER

File details come from the government source that posted it. Updated .