This document is an appendix listing 24 physical security door systems at a Veterans Affairs Medical Center facility requiring replacement. It details the location, type, size, and physical requirements of each door, along with notes indicating full removal and replacement of existing door systems is required. The related federal contract opportunity solicitation seeks proposals to replace damaged doors and upgrade the card access system at the same VAMC facility in West Roxbury, Massachusetts in accordance with specifications, drawings, and applicable federal, state and local codes. Work will include construction administration, demolition, doors, card access physical access control systems, mechanical, electrical, and other requirements. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1 is the contracting agency.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 523A4-12-207 Site Walk 1-10-24.pdf | ||
| 36C24123R0181 0004.docx | DOCX document | |
| 36C24123R0181 0003.docx | DOCX document | |
| Replace Damaged Doors RFI Answers 1-8.docx | DOCX document | |
| S02 - MA WD 01-19-24.txt | TXT text file | |
| 36C24123R0181 0002.docx | DOCX document | |
| S02 - 523A4-12-207 Drawings.pdf | ||
| 36C24123R0181 0001.docx | DOCX document | |
| S02 - Lead Report Map.pdf | ||
| S02 - MA WD 12-8-2023.txt | TXT text file | |
| S02 - Damaged Doors PCRA.pdf | ||
| S02 - Survey Report W Roxbury Bldg 01.pdf | ||
| S02 - Damaged Door ICRA.pdf | ||
| P03 - SSJ.pdf | ||
| S02 Past Performance Questionnaire.docx | DOCX document | |
| S02 - Itemized Price Breakdown.xlsx | XLSX spreadsheet | |
| S02 - W Roxbury - Volume 1 - FINAL.pdf | ||
| S02 - VAMC Doors PACS work narrative.pdf | ||
| S02 - Revised Specifications.pdf | ||
| S02 - SOW.docx | DOCX document | |
| 36C24123R0181 RFP.docx | DOCX document |
Show all 21
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Appendix‐ A‐ List of Physical Security Door Systems
Basement of Building 2 ‐ Exterior Doors
Count # Door Opening # Loca on Door Type Size Blast /physical design reqts per VA design
Comments
1 AB16 111.A
Figure 1
Basement‐ Bldg 2
HM‐ Swing Door ‐ Outwards.
Single Leaf w/vision panel
3’8” x 6’8” Yes Full removal of exis ng door system, Replacement with new door system. Wall susbstrate is exis ng concrete or masonry
2 AB17 111.C
Figure 1
Basement‐ Bldg 2
HM‐ Swing Door ‐ Outwards.
Double Leaf w/ vision panel
3’8” x 8’‐6” 3’8” x 8’‐6”
Yes Full removal of exis ng door system, Replacement with new door system. Wall susbstrate is exis ng concrete or masonry
Figure. 1 sjdun Highlight Blast /physical design reqts per VA design
Ground Floor‐ Building 1.
Count Number
Door Opening #
Loca on Door Type Size Blast /physical design reqts per VA design
Comments
3 DST1‐GA
104.A1
Figure 2
Ground Floor‐ Bldg 1
HM‐ Swing Door ‐ Outwards.
Single Leaf
3’8” x 7’ Yes Full removal of exis ng door system, Replacement with new door system.
Wall susbstrate is exis ng concrete or masonry
4 DST3‐GA
104.A1
Figure 3
Ground Floor‐ Bldg 1
HM‐ Swing Door ‐ Outwards.
Single Leaf w/vision panel
3’8” x 7’
Replacement with new door system.
Wall susbstrate is exis ng concrete or masonry
5 DGD‐129C
111.A Figure 4
Ground Floor‐ Bldg 1
HM‐ Swing Door ‐ Outwards.
Single Leaf
3’ x 7’ Yes Full removal of exis ng door system, Replacement with new door system.
Wall susbstrate is exis ng concrete or masonry
6 CGC‐104
103.C2 Figure 4
Ground Floor‐ Bldg 1
HM‐ Swing Door ‐ Outwards.
Double Leaf with narrow vision panels
Custom 3' x 7'‐0" 2' x 7'‐0"
Yes Full removal of exis ng door system, Replacement with new door system.
Wall susbstrate is exis ng concrete or masonry
7 DST2‐GA
104.A1
Figure 5
Ground Floor‐ Bldg 1
HM‐ Swing Door ‐ Outward.
Single Leaf narrow vision glass + transom framing/panel
3'‐8" x 7'‐0"
Plus transom
Yes Full removal of exis ng door system, Replacement with new door system.
Wall susbstrate is exis ng concrete or masonry
8 CST5‐GA
104.A1
Ground Floor‐ Bldg 1
HM‐ Swing Door ‐ Outwards.
Figure 6 Single Leaf With narrow vision panel + transom
Transom frame/plate
Wall susbstrate is exis ng concrete or masonry
9 BST6‐GA
104.A1 Figure 7
Ground Floor‐ Bldg 1
HM‐ Swing Door ‐ Outwards.
Single Leaf With narrow vision panel
Wall susbstrate is exis ng concrete or masonry
10 BST8‐GA
104.A1 Figure 8
Ground Floor‐ Bldg 1
HM‐ Swing Door ‐ Outwards.
Single Leaf With narrow vision panel
Wall susbstrate is exis ng concrete or masonry
Figure 2 Figure 3 Figure 4
Figure 5 Figure 6 Figure 7
Figure 8
Ground Level – Building 2
‐ Figure 9 Figure 10
Building 3‐ Ground Level
Figure 12 Figure 13
Building 2 – Ground Level Exterior Doors
Count # Door Opening # Loca on Door Type Size Blast /physical design reqts per VA design
Comments
11 AST1‐GA 104.A1
Figure 9
Ground Floor‐ Bldg
HM‐ Swing Door ‐Outwards.
Single Leaf w/narrow vision panel
3’10” x 6’8”
12 A‐G15‐A 104.A1 Figure 10
Ground Floor‐ Bldg
HM‐ Swing Door ‐Outwards.
Single Leaf‐ stainless steel door
13 AST2‐GA 104.A1
Figure 10
Ground Floor‐ Bldg
HM‐ Swing Door ‐Outwards.
Single Leaf with narrow vision
Building 3– Ground Level Exterior Doors
14 BCG‐1A 101.A1
Figure 12
Ground Floor‐ Bldg 3
Aluminum Frame Double Vision‐ Swing Door Outwards.
Single Leaf
3’ 6” x 7 ‘ Yes Full removal of exis ng doo system, 15 BST2‐GA 104.A1
Figure 13
Ground Floor‐ Bldg 3
HM‐ Swing Door ‐Outwards.
Single Leaf + Transom system
3’ 6” x 7 ‘
16 AST1‐GA 104.A1
Figure 14
Ground Floor‐ Bldg 3
HM‐ Swing Door ‐Outwards.
Single Leaf +Transom System
3’ 0” x 7 ‘
17 AGA‐168 103.A2
Figure 15
Ground Floor‐ Bldg 3
HM‐ Swing Door ‐Outwards.
3’ 0” x 7 ‘
19 CCG‐27C 103.A2
Figure 16
Ground Floor‐ Bldg 3
HM‐ Swing Door ‐Outwards.
Single Leaf with narrow vision
Yes
Full removal of exis ng door system, 20 CG‐100A 111.A2
Figure 17
Ground Floor‐ Bldg 3
HM‐ Swing Door ‐Outwards.
With custom framing
Full removal of exis ng door system, 21 CGC‐100B 111.C
Ground Floor‐ Bldg 3
HM‐ Swing Door ‐Outwards.
Double Leaf With transom system
3’ 8” x 7 ‘
3’ 8” x 7 ‘ +transom plate and framing
22 CGC‐104 111.C
Ground Floor‐ Bldg 3
HM‐ Swing Door ‐Outwards.
Double Leaf
3’ 8” x 7 ‘
3’ 8” x 7 ‘ +transom plate and
23 DST4‐GA 104.A1
Figure 19
Ground Floor‐ Bldg 3
HM‐ Swing Door ‐Outwards.
Single Leaf
Transom pla ng and
24 03-CGC-116C Exterior Pharmacy
15‐MIN RATED
FE Door System
SD-STD-
01.01 15 MiN Forced Entry
Forced Entry Resistance, Exterior Pharmacy -minute Forced Entry Door 03-CGC-116C: Door and frame shall comply with SD-STD-01.01 15-minute Forced Entry door construction
Figure 14 Figure 15
Figure 16 Figure 17
Figure 19
File details come from the government source that posted it. Updated .