This statement of work outlines requirements for replacing the physical access control system at multiple South Texas Veterans Health Care System facilities. Key requirements include replacing the existing C-Cure 9000 system with a turnkey PACS solution that meets all applicable federal standards. The new system must support over 600 doors across seven facilities located in San Antonio, Kerrville, Victoria and other Texas cities. Offerors must be authorized dealers for PACS equipment and have technicians available locally to service the account. The contract will have a one year warranty and require training five VA staff members. Responses to this sources sought notice are due by January 25th, 2023 to help determine procurement strategy such as set asides. The agency intends to post a solicitation soon after for this requirement.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
South Texas Veterans Health Care System Physical Access Control System
STATEMENT OF WORK
1.0 SCOPE
The South Texas Veterans Health Care System (STVHCS) requires replacement of current C-Cure 9000 PACS with a turn-key PACS that meets all VHA & USG FIPS and PACS requirements at locations outlined in the below SOW.
| STVHCS Location |
| Location Address |
| Audie L. Murphy Memorial VA Hospital |
| 7400 Merton Minter Blvd, San Antonio, TX, 78229-4404 |
| Northwest Health Care Center |
| 9939 State Highway 151, San Antonio, TX 78251 |
| Kerrville VA Medical Center |
| 3600 Memorial Blvd, Kerrville, TX 78028-5768 |
| Villa Serena Treatment Facility |
| 4455 Horizon Hill, San Antonio, TX 78229 |
| North Central Federal Clinic |
| 17440 Henderson Pass, San Antonio, TX 78232-1662 |
| Fisher House |
| 7485 Wurzbach Rd, San Antonio, TX 78229 |
| VA Polytrauma Transitional Housing (PTRP) |
| 4949 Gus Eckert Road, San Antonio, TX 78240 |
| Victoria Outpatient Clinic |
| 1908 North Laurent Street, Suite 150, Victoria, TX 77901 |
2.0 DESCRIPTION OF WORK
a. Contractor shall replace the existing Physical Security and Access Control system (PACS) with a system that is listed in order of priority in the event there is a conflict between the standards.
1. FIPS 201 / PACS 13.02 / FIPS 140-2 compliant, and meets requirements of:
2. VA Directive 0735, “Personal Identity Verification (PIV) of Federal Employees and Contractors”.
3. VA Handbook 0730/2, “Security and Law Enforcement”.
4. VA Handbook 6500, “Information Security Program”.
5. NIST Special Publication SP800-53REV3, “Recommended Security Controls for Federal Information Systems and Organizations”.
6. NIST SP800-116
b. The contractor will supply all software, hardware, database conversions, programming, and additional equipment/parts as necessary to deliver a fully functional Physical Access Control System (PACS) as defined in the OEM service manual or other related OEM documentation, covered by this contract, in accordance with the Conformance Standards Section. The Contractor stipulates by submission of a response to this solicitation such proprietary software, upgrades and parts will be sourced from the manufacturer. All proprietary licensed software and parts supplied shall be of current manufacture and have full compatibility with existing equipment. Documentation of intended parts source shall be provided to the Contracting Officer upon request. All parts necessary for the installation and certification of this system shall be furnished as part of this contract. Refurbished or used parts will not be acceptable.
c. All card readers are to function with all PIV class cards and have full 2FA with pin pad, that validates USG PIV certificates.
d. Design and construction are to include one for one replacement of existing field points.
e. In addition to equipment replacement, contractor is to standardize wiring, color coding, and device configurations as equipment is replaced including CAT6 cabling.
f. All detection devices on the system are to be configured and installed as three state devices.
g. All peripheral equipment shall be secured in the security network communication closets, with the exception of end of line field devices.
h. All buildings will have at minimum, first floor perimeter security (exterior doors monitored by the system) and one door per building is to be controlled by a card reader from the system. Additional perimeter door readers will be selected by the design team using the number of staff occupants, type of security required for function, size of building, and distance between entrance doors. 100 employees or more shall require additional reader doors. An employee only controlled areas such as Pharmacy shall require additional reader doors. A distance of 150 feet or more between entrances shall require additional reader doors.
i. This system is to monitor, control, and operate the Audie L. Murphy Memorial VA hospital ALMD, Kerrville VAMC, North Central Federal VA Clinic, Victoria VA Clinic, Villa Serena, and VA Polytrauma Transitional Housing (PTRP), and Northwest Healthcare Center (NWHCC).
j. This system will operate under a single database allowing for global, instantaneous configuration changes.
k. The system will also be used to control the road/gate entrances to the Medical Center by using hydraulic bollards or electrical wedge gates. The expansion shall allow full electrical/electronic control of all first floor building entrances and station entrance gates, to include securing or unlocking and monitoring from the system work stations.
l. Electronic locking of doors to be fail secure for ingress and shall allow free egress, except in the CLC- buildings. In the CLC doors are controlled by time code for card in/card out operation.
m. Design and construction are to use existing pathways where feasible and require new pathways where needed.
n. Design and construction will size pathways to a maximum fill rate of 50%.
o. Existing pathways are to be cleared of any abandoned conductors, prior to using the pathway.
p. No splices or connections will be permitted outside of communications closets, except for end device connections, unless specifically approved by the COTR in writing.
q. All Nodes (controller) to device wiring to be new and unbroken.
r. Warranty coverage for the installed system shall be a minimum of 1 full year from date of project acceptance
1. Covered hardware failure
2. Programming
3. Software licensing
4. Technical consulting / support, to include on-site support as needed.
s. Full maintenance/system management and administration training on the installed system for at least Five STVHCS staff members
1. Provided onsite STVHCS, or at the ACS’ manufacturer’s training location.
2. Including tuition and travel costs, if applicable.
t. Full as built drawings must be provided to STVHCS upon completion of project.
u. Complete assessment of current C-Cure 9000 system must be completed before installation to verify current operating status, data corruption and correct client / staff count.
v. Vendor must complete enrollment of all STVHCS employees and contractors into new PACS, with training to any STVHCS staff as needed on the enrollment process. Vendor will also need to create user groups, door schedules etc. with assistance from VHA staff for details.
w. Any network hardware i.e., laptops needed for any portion of the installation must be provided by the vendor.
x. Fisher House Requirements:
1. Requires an enterprise hotel solution that enables on site staff to monitor, run reports on access, issue visitor and staff access cards, must be able to integrate to main PACS system if and when necessary for monitoring purposes only.
2. No PIV Class requirement for this location, all materials must be able to replace or integrate with current SALTO system.
y. PACS must be able to control, modify and monitor all locations from Audie L. Murphy.
z. Provide the ability to troubleshoot, repair and install components of the PACS such as mag locks, door operators, contact point etc. on an as needed basis during the installation.
3.0 VENDOR SPECIFIC REQUIREMENTS
a. Must be currently registered in SAM’s and VHA Vista vendor system.
b. Must be a certified installer / integrator of ALL the following PAC systems currently installed and owned by VA:
| i. C-Cure 9000 |
| ii. Hirsch |
| iii. Genetec |
c. Must have technicians in the South Texas area to respond to STVHCS service calls in a reasonable amount of time.
d. Must use a manufacturer with products that have been proven to work within the VHA system and meets the FIPS 201, PACS 13.02 and FICAM compliance and is an approved USG PACS Validation Infrastructure product listed on idmanagement.gov.
e. Must have a Certified System Engineer ICAM PACS Technician.
f. Manufacture parts must be a GSA Approved Partner.
4.0 THE PHYSICAL SECURITY SYSTEM AND MANAGEMENT SOFTWARE MUST HAVE:
a. Support a thin client model
b. Microsoft Active Directory Integration
c. Administrative users can be configured to use Microsoft Active Directory for authentication.
d. Capability to create badge templates, badge printing, taking user photographs, and enrolling users into the user database.
e. Areas (comprised of a group of doors) and users can be assigned entry permission based on schedules.
f. Administrative users can be assigned permissions. User profiles can be tailored very specifically.
g. Cardholder credentials can be edited, including system wide card formats.
h. Provide a view of events and alarms in the system. Alarm and event views can be filtered based on several criteria.
i. Events (contact closure inputs or card access denied, for example) can be associated to actions (activate output contact closures, send an e-mail, etc.).
j. Standard and custom reports can be created.
k. Provides a log of all administrative use of the system, arranged by user.
l. Ability to allow system to be synchronized with data from either external SQL databases or Microsoft Active Directory.
m. License files (capacity upgrades or feature additions) can be added.
n. Allow a user to administer the system, by performing tasks such as IP address assignment.
o. Configuration can be backed up to an external server.
p. Previously backed up configuration can be restored from an external server.
q. Warm standby redundancy
r. HTTP/S URLs can be invoked as a result of any event or alarm. Event data can be inserted in the URL to integrate with any external application that accepts URL invocations
s. SQL database servers, application servers and any other network servers need to be virtual machines.
t. All software must have a current VA Enterprise Risk Analyses (ERA) approved on the VA Technical Reference Model (TRM).
5.0 FACILITY POINT OF CONTACT
a. VA Contact Person: Mr. Abdias Villanea, Mr. Lavonne Melton, or Mr. Alrufaiee Omar
b. Contractor Telephone Number(s) of Service Department: 210-617-5300 ext. 15721
6.0 Additional Charges
There shall be no additional charge for time spent at the site (during or after the normal hours of coverage) awaiting the arrival of additional FSE and/or delivery of parts.
7.0 COMPLIANCE WITH SECURITY REQUIREMENTS
| a. | Identification: |
| i. | All contractors working shall be fingerprinted prior to being allowed to work on campus. Contractor ID badges can be obtained from PIV office typically 3-5 days after approved SAC form is received and fingerprints clear. ID badges are required for contractor employees working at Audie L. Murphy Medical Center. |
| b. | Contractor Personnel Vaccinations: |
| i. | Seasonal Influenza Vaccination/Tuberculosis Testing: |
| A. | VHA Directive 1192.01 establishes policy and provides guidance for the prevention of seasonal influenza in VHA facilities, through the vaccination of health care personnel (HCP). HCP are individuals who, during the influenza season, work in VHA locations or who come into contact with VA patients or other HCP as part of their duties. HCP include all VA contractors who are expected to perform any or all of their work at VA facilities. Contracting Officers shall ensure the flu vaccination requirements outlined in this directive are expected in all HCP contracts. VA contracting officers are responsible for on-site HCP contract and will inform the contractors about this directive and its requirements. |
| ii. | Tuberculosis Testing: |
| A. | All Contractor personnel who will be working onsite must provide documentation of a completed tuberculosis (TB) skin test within the prior year before beginning work. |
| c. | Parking: |
| i. | It is the responsibility of the Contractor to park in the appropriate designated parking areas. Information on parking is available from the VA Police Section. The VAMC will not validate or reimburse for parking violations from the Contractor under any conditions. |
| d. | Smoking, Weapons, and VA Regulations |
| i. | Smoking and vaping are prohibited inside any building at the VAMC and on the STVHCS campus (including parking areas). Possession of weapons is prohibited. Enclosed containers, including tool kits, shall be subject to search. Violations of the VA regulations may result in citation answerable to the United States (Federal) District Court, not a local district, State, or Municipal court. |
| e. | Vaccinations and Trainings |
| i. | All contractors must show proof of NEGATIVE TB test results, annual Flu vaccination, and any other requirements deemed necessary by Infection Prevention or the Secretary of the Departments of Veteran Affairs. |
| ii. | All contractors must attend a mandatory Infectious Control Training held every Tuesday at 10 am at the Audie L. Murphy Memorial Hospital located at 7400 Merton Minter, San Antonio, Texas 78229, room E002. |
| iii. | All contractors must present any additional information deemed necessary at/during the time of project by Infection Prevention or the Secretary of the VA. |
8.0 TECHNICAL REQUIREMENTS
The Contractor shall deliver the hardware and equipment with the following requirements:
| a. | Install PACS-13.02 compliant card readers. |
| b. | Run all new cabling for all field devices. |
| c. | Provide CAD drawings for all panel terminations and line diagrams. |
| d. | Provide and install all network drops which include cable, ports as per manufacturers’ recommendations and drawings. |
| e. | Provide all patch panels, patch cables, patch cord or panels. |
| f. | Provide all permits and inspections. |
g. Provide a timeline for work progress that should not exceed 180 days from the time of contract award to deliver a complete working system.
9.0 SECURITY
| a. | The contractor shall provide security for the vendor provided equipment. |
| b. | The Contractor shall provide for the physical security of Contractor equipment, as needed. VA shall provide the Contractor with escorted access to the wiring closets. |
| c. | Log files must be maintained for a one-year period. |
| d. | The Contractor shall adhere to all physical security and badge identification outlined by the VA Police while on site. |
10.0 DEFINITIONS/ACRONYMS
| a. | Acceptance Signature – VA employee who is authorized to sign-off on the ESR, which indicates that the PM has been concluded or is still pending completion, or that the Emergency Repair has been accomplished or is still in a pending status. |
| b. | Authorization Signature – the COR’s signature; indicates that the COR accepts work status as stated on the ESR. |
| c. | CO – Contracting Officer |
| d. | COR – Contracting Officer’s Representative |
| e. | VAMC – Department of Veterans Affairs Medical Center |
f. USG – United State Government
11.0 INFORMATION SYSTEMS OFFICE, INFORMATION PROTECTION
The contractor will not have access to VA Desktop computers, nor will they have access to online resources belonging to the government while conducting services. If removal of equipment from the VA is required, any memory storage devices, such as hard drives, solid state drives and non-volatile memory units will remain in VA control and well not be removed from VA custody.
If access is needed the ISSO and COR will be contacted.
12.0 PRIVACY OFFICER
The contractor will not have access to protected Patient Health Information (PHI) nor will they have the capability of accessing patient information during the services provided to the VA and if removal of equipment from the VA is required, any memory storage devices, such as hard drives, solid state drives and non-volatile memory units will remain in VA control and will not be removed from VA custody. All research data available for Contractor analyses is de-identified.
13.0 RECORDS MANAGER
There will be no federal records created, maintained, used or dispositioned with this contract; regardless of format [paper, electronic, etc.] or mode of transmission [e-mail, fax, etc.].
14.0 TYPE OF CONTRACT
STVHCS anticipates award of a FIRM FIXED PRICE contract based on the contents of this solicitation.
15.0 SECURITY REQUIREMENTS
The C&A requirements do not apply, and a Security Accreditation Package is not required.
16 SITE VISIT
A site visit is encouraged for the location of all the STX PACS systems for this requirement, interested Offerors shall contact the below points of contact via email to schedule a site visit available in the below dates. Prospective Offerors are responsible for all expenses related to the site visit. This site visit is not to provide a proposal, but to prepare a capability statement.
Points of Contact to schedule a site visit Omar Alrufaiee omar.alrufaiee@va.gov Lavone Melton lavonne.melton2@va.gov Frank Mendoza francisco.mendoza@va.gov
Available Site Visit Days 01/25/2023 08:00 AM to 1:00 PM 01/26/2023 08:00 AM to 1:00 PM 01/27/2023 08:00 AM to 1:00 PM 01/30/2023 08:00 AM to 1:00 PM 01/31/2023 08:00 AM to 1:00 PM
File details come from the government source that posted it. Updated .