OH0189CN - J.W. Peck Building Asbestos Notification Letter (12_2019).pdf

PDF 120 KB Posted

Attached to
Cincinnati Elevator Services Federal contract opportunity
Solicitation number
Not on record
Issued by
General Services Administration Public Buildings Service Region 5

View the file

Other files for this federal contract opportunity

Other files attached to Cincinnati Elevator Services, newest first.
File Type Posted
RFI 3.pdf PDF
RFI 2.pdf PDF
PreProposal Conference Attendance .pdf PDF
Walk Thru Sign in.pdf PDF
Pre-Proposal Conference Agenda.pdf PDF
RFI 1.pdf PDF
J.13 Hydraulic Elevator Checklist 08-2018.pdf PDF
OH0028CN - Potter Stewart CTHSE Asbestos Notification Letter (11_2019).pdf PDF
Contractor Proposal Worksheet - Peck 2.13.20.xls XLS spreadsheet
Contractor Proposal Worksheet - PSCH 2.13.20.xls XLS spreadsheet
Contractor Proposal Worksheet - FDA 2.13.20.xls XLS spreadsheet
J.7 Elevator Inspection Form.pdf PDF
RFP 47PF0021Q0095.pdf PDF
GSA527-15e (1).pdf PDF
J.13 Electric Traction Elevator Checklist 08-2018.pdf PDF
Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Date: 05/04/2020

Prospective Contractors (bidders), Pursuant to the Code of Federal Regulations all building owners are required to provide notification of the presence, location, and quantity of asbestos containing materials (ACM) and presumed asbestos containing materials (PACM) in their facilities. This notification is provided as a safeguard, to ensure prospective contractors (bidders) are aware of this information.

Asbestos containing material is present in the John Weld Peck Building (OH0189CN) in the following forms, locations, and quantities:

Type Location Quantity

Fittings on Fiberglass Line Throughout Building 21200 ea

Tank Insulation Sub-Basement Mechanical Room 800 sf

Duct Insulation Throughout 19000 sf

Elevator Door Insulation Throughout 1300 sf

Mastic on AHU Supply Duct Throughout Building Supply Duct 13600 sf

Caulk (Painted Grey) Sub-Basement Mechanical Room 10 lf

Roofing Materials Main & Penthouse Roof 67000 sf

Electrical Conduit Putty 3rd Floor West Hall Telephone Closet 100 sf

Interior Window Glazing

Throughout Building Undefined

Mastic on Car Shell Freight Elevator Car Shell 500 sf

Insulation on Converter Tank Penthouse 500 sf

Floor Tile and Mastic Throughout Building 634350 sf

Ceiling Tile 1st & 3rd Floor 5400 sf

Gold HVAC Sealant 7th Floor Hallway Undefined

Mastic Associated with 12”x12” White Floor Tile with Tan Specks

2nd, 7th, and 9th Floor Undefined

Mirror Mastic Throughout Undefined

Fire Doors Throughout Undefined

If you have any questions, please contact Jena Richter at 513/246-4418 or Jennifer.richter@gsa.gov for the procurement.

Denotes material was not tested at the time of the most recent survey. Testing is not feasible in some cases as it would result in damage to the material or its structural components. In other cases, the material or area may not have been accessible. As such, the material must be presumed to be ACM based on its characteristics, age or other technical factors. Material is presumed to be ACM to ensure appropriate precautions and methods are employed when contemplating or executing activity that may disturb the material.

Quantity was not defined at the time of the most recent survey.