KCDME051.pdf
PDF 120 KB Posted
- Solicitation number
- NWWP4000-19-00072MWH
About this file
Mechanical prints for the two locations
View the file
Other files
| File | Type | Posted |
|---|---|---|
| CRP_WFO_Mech_dwgs.pdf | ||
| KCDME062.pdf | ||
| KCCOM041.pdf | ||
| KCCOM051.pdf | ||
| KCDME042.pdf | ||
| KCDME032.pdf | ||
| KCCOM062.pdf | ||
| KCCOM031.pdf | ||
| BMX_WFO_Mech_dwgs.pdf | ||
| 19-00072_-_SF_18_Quote_Form.doc | DOC document | |
| 19-00072_-_SOW-CRP_HVAC_Controls_Replacement_Updated_Rev_4Mar19_-_FBO.pdf | ||
| 19-00072_-_SOW-BMX_HVAC_Controls_November_1,_2018_Rev_4Mar19_-_FBO.pdf | ||
| Calera_AL_SCLS.pdf | ||
| Corpus_Christi_TX_SCLS.pdf |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LOCATION
EXACT CONNECTION
DWG E10 FOR
SEE SECTION 8,
TRANSFORMER
UTILITY
NEUTRAL
GENERATOR
BOND TO
"PG"
PANEL
SKID
GENERATOR
BOND TO
NEXRAD RADAR SITE
DISCONNECT SWITCH
0 4' 8' 16' 24'
SCALE: 1/8"=1'-0"
CONTINUATION
SEE DWG E04 FOR
TO UPPER AIR BLDG
#4/0 GUARD WIRE
(ONLY AT THIS TEST WELL)
CU GND WIRE
INSULATED
250KCMIL
WATER LINE
BELOW ACCESS FLOOR
TELCO GND BAR
TEST WELL GROUND ROD
DISCONNECTED FROM
COUNTERPOISE
LEAVE ONE END OF
CU GND WIRE
INSULATED
250KCMIL
3 PLACES
TYPICAL
F E
D
C
B
A
6 5 4 3 2 1
DISCONNECT SWITCH
SERVICE ENTRANCE
PPC
PPB
PPA
NOTES
NORTH
BUILDING
SCALE: 1/8"=1'-0"
GROUNDING PLAN
OPERATIONS
J
#6 BARE COPPER
GROUND WIRE
FUEL
TANK
0"10'-0"
0"
9'-0"
10'-0"
0"
EQUIPMENT GROUNDING
PLATE DETAIL
GROUND
PLATE
#250 KCMIL BARE
CU GND WIRE TO
COUNTERPOISE OR GND ROD
GROUND ROD
WELD (TYP)
EXOTHERMIC
10" (UNO)
COUNTERPOISE
FLOOR
ACCESS
GRADE
GROUND TEST WELL
SECTION
SCALE: NONE
BOND #4 BARE COPPER
GROUND WIRE TO ACCESS
FLOOR SUPPORT (TYPICAL
2 PLACES)
COORDINATE GROUND PLATE LOCATIONS
WITH FLOOR GRID TO AVOID PEDESTALS,
SEE DWG A02. FOR INSTALLATION OF
GROUND PLATE, SEE DETAIL 2,, THIS
DRAWING (TYPICAL 6 PLACES UNDER
ACCESS FLOOR)
#4 BARE CU GND WIRE.
SEE DWG M07 FOR DETAIL
OF CONNECTION TO FUEL
TANK
6"x6"x4" DEEP RECESSED
JUNCTION BOX WITH BLANK
COVER PLATE. MOUNT 12" AFF
AND COIL 12" OF #6 BARE
CU GND WIRE IN BOX
DETAIL
SCALE:
-NONE
OU DO
ASK
VERY
IRST WITH
LWAYS BE
AFETY SHOULD
Y T E F A S
N
OI
T A
R T
SI
NI
M
DA
A
A CIREHPSOMTDN
CI
NA
E
CO
LA
N
OI
T A N
EC
I
FF
O
MA
RGO
RPGNIREENIGNE
LAI
CE
P S
DRAWN
CHECKED
SUP'V. ENGR.
ENGR/PROJ. MGR.
ACOTR./COTR.
SIZE DWG. NO. CLIN. REV.
SPECIAL ENGINEERING PROGRAM OFFICE (SEPO)
NO. DATE PREPARED
BY
CHECKED
BY
ACTR/COTR
APPROVEDAPPROVED
FDI DESCRIPTION OF REVISION
WFO / NEXRAD PROGRAM
PROJECT NO.
PROGRAM MANAGEMENT
SERVICES CONTRACTOR
GOULD EVANS
ARCHITECTS, P.A.
U.S.A.
KANSAS CITY, MO.
FD
SP
K C D M E0
E05 DM 1
CORPUS CHRISTI, TEXAS
WEATHER FORECAST OFFICE
ELECTRICAL
GROUNDING PLAN
L J FOSTER
L J FOSTER
T M SUPER
MJM/TLS
JTS
044131-
DM01
:2
M D P
PPB1
UNDER ACCESS
FLOOR
GND WIRE
#4 BARE CU
COPPER WIRE AND 4 BOLTS INSTALLED ON PLATE.
PROVIDE 4 LUGS SIZED FOR #4 AWG STRANDEDNOTE:
CONCRETE
COLLAR
6" CRUSHED
STONE
250KCMIL BARE CU GROUND WIRE,
UNLESS OTHERWISE NOTED. USE
SELF-LAMINATING WRITE-ON WIRE
AND CABLE MARKERS TO IDENTIFY
EACH GROUND WIRE
TO ASTM C76, CLASS III.
PIPE SECTION, PIPE SHALL CONFORM
24"Ø x 2'-6" LONG CONCRETE
CLEAN SAND
CONNECTOR
GROUND ROD
1'
0" FILL
1' 0"
1' 0"
(TYP)
1"
#4
AND FRAME
ACCESS COVER
OPENING
2'-0" DIA
3'-0" DIA
JOINT MATERIAL
1" ISOLATION
6"
CONNECTION TO GROUND PLATE SHALL BE MADE WITH
A MECHANICAL CONNECTOR.
BOND TO TUBE COLUMN, SEE DWG S11 FOR EXACT LOCATION.
GROUND TEST WELL FRAME AND COVER SHALL BE
CASTINGS FABRICATED FROM GREY IRON CONFORMING
TO ASTM A48. FRAME AND COVER SHALL BE SUITABLE
FOR LIGHT TRAFFIC, CONCRETE SLAB APPLICATIONS.
COVER SHALL BE NON-ROCKING AND SHALL BE
LETTERED "ELECTRIC".
INSTALLATION SIMILAR TO DETAIL 2, THIS DRAWING.4
MECHANICAL
CONNECTION
#4/0 BARE CU
GUARD WIRE ABOVE
RDA CONDUITS, SEE
DWG EO4
U-1 U-2
20'-0"
ROHN
TOWER
ROHN
TOWER
#4/0 BARE CU GND WIRE,
TO WFO COUNTERPOISE
GROUNDING FOR ROHN TOWER TO BE LOCATED 4'-0" OUTSIDE
OF TOWER FOUNDATION. USE 4/0 BARE CU GND WIRE FOR
COUNTERPOISE AND #4 BARE CU WIRE TO CONNECT TO
TOWER AT TWO LOCATIONS WITH GROUND LUGS PROVIDED WITH TOWER.
#4/0 BARE CU GND WIRE,
TO DISH ANTENNA,
SEE DWG E04
1 6/6/96 MCK REVISED PER AS-BUILT CONDITIONSTMS ERP/RRW FGR/JAB
LOCATION
EXACT CONNECTION
DWG E10 FOR
SEE SECTION 8,
TRANSFORMER
UTILITY
"PG"2
NEXRAD RADAR SITE
DISCONNECT SWITCH
DISCONNECT SWITCH
SERVICE ENTRANCE
J
#6 BARE COPPER
GROUND WIRE 10'-0"
OU DO
ASK
VERY
IRST WITH
LWAYS BE
AFETY SHOULD
Y T E F A S
N
OI
T A
R T
SI
NI
M
DA
A
A CIREHPSOMTDN
CI
NA
E
CO
LA
N
OI
T A N
EC
I
FF
O
MA
RGO
RPGNIREENIGNE
LAI
CE
P S
DRAWN
CHECKED
SUP'V. ENGR.
ENGR/PROJ. MGR.
ACOTR./COTR.
SIZE DWG. NO. CLIN. REV.
SPECIAL ENGINEERING PROGRAM OFFICE (SEPO)
NO. DATE PREPARED
BY
CHECKED
BY
ACTR/COTR
APPROVEDAPPROVED
FDI DESCRIPTION OF REVISION
WFO / NEXRAD PROGRAM
PROJECT NO.
PROGRAM MANAGEMENT
SERVICES CONTRACTOR
GOULD EVANS
ARCHITECTS, P.A.
U.S.A.
KANSAS CITY, MO.
FD
SP
K C D M E0
E05 DM 1
CORPUS CHRISTI, TEXAS
WEATHER FORECAST OFFICE
ELECTRICAL
GROUNDING PLAN
L J FOSTER
L J FOSTER
T M SUPER
MJM/TLS
JTS
044131-
DM01
:2
M D P
#4/0 BARE CU
GUARD WIRE ABOVE
RDA CONDUITS, SEE
DWG EO4
U-1 U-2
PC NO.
BY
CHECKED
SITE
DATE
FD
SP
PC-07-DM-E05-0
05/18/95
CORPUS CHRISTI, TEXAS