About this file

Mechanical prints for the two locations

View the file

Other files

File Type Posted
CRP_WFO_Mech_dwgs.pdf PDF
KCDME062.pdf PDF
KCCOM041.pdf PDF
KCCOM051.pdf PDF
KCDME042.pdf PDF
KCDME032.pdf PDF
KCCOM062.pdf PDF
KCDME051.pdf PDF
BMX_WFO_Mech_dwgs.pdf PDF
19-00072_-_SF_18_Quote_Form.doc DOC document
19-00072_-_SOW-CRP_HVAC_Controls_Replacement_Updated_Rev_4Mar19_-_FBO.pdf PDF
19-00072_-_SOW-BMX_HVAC_Controls_November_1,_2018_Rev_4Mar19_-_FBO.pdf PDF
Calera_AL_SCLS.pdf PDF
Corpus_Christi_TX_SCLS.pdf PDF
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SEAL ALL DUCT JOINTS WATERTIGHT.

CONNECT 8"Ø FLEXIBLE DUCT TO 12x12x24 PLENUM BOX IN SOFFIT.

BOTTOM OF GRILLES IN SOFFIT TO BE @ 7'-6" AFF (TYPICAL 3 PLACES).

CEILING PLAN (DWG A06).

COORDINATE DIFFUSER LOCATIONS IN LAY-IN CEILING WITH THE REFLECTED

ACCESS OPENING IN CEILING (SEE ARCHITECTURAL DWG A06).

FOR CONTINUATION, SEE MECHANICAL EQUIPMENT SPACE PLAN, DWG M04.

PROVIDE PIPE SLEEVES WITH MECHANICAL SEAL FOR REFRIGERANT PIPES.

FLEXIBLE REFRIGERANT PIPE CONNECTION.

REFRIGERANT LINE SUPPORT. SECURE CHANNELS TO SLAB WITH EXPANSION ANCHORS.

PROVIDE CHANNELS 4" HIGH WITH TUBING CLIPS WITH RUBBER ISOLATORS FOR

8"Ø MD

PAC

(GFE)

(BOTTOM @

10'-0" AFF)

2 MOD

MOD T

AHU-1

7/8"-RL

2 1/8"-RS

2 1/8"-RS

7/8"-RL

AHU-2

R A B

O O T x1

B-12x24

R A B

O O T

(TYPICAL 2)

8x

EDH

45°up

EQUIPMENT SPACE)

COMPONENTS (IN MECHANICAL

TO TEMPERATURE CONTROL

MDMD

MD

MD

MD

(T

YP

4' 0"

17TERMINAL

TEMP CONTROL

8x8

MD

MD MD

MD

x2

C

(GFE)

ACU

ACU

ACU

(2 CIRCUITS PER UNIT)

7/8" HG, 1/2" RL

2 (GFE)

C

M04

M04

M04

M04

D

E

F

C

A

B

VEST

WAITING

FILE/COPY

JAN

1 2 4 6 7

F

E

D

C

B

A

7654321

6x6

EDH

M04

BOOT UP 12" (TYPICAL 2)

24x48 BOOT - TURN

BDD

BDD

AD

(18x18)

T

(2)36x24

36x24

8"Ø

18x12 OP'NG (TYP 2)

E-12x12

E-12x12

C-12x12

PROVIDE 14 PERFORATED FLOOR PANELS. INSTALL 12 PANELS IN

(TYPICAL 2)

E-30x24 x1

6x

8x

18x12

8x6

PROVIDE GRILLE OF ALUMINUM CONSTRUCTION.

ANCHOR CONDENSING UNITS TO SLAB.

CONCRETE HOODS (SEE STRUCTURAL DWG S04).

ALARM AND INDICATOR LIGHTS PANEL.

REMOTE CONTROL BOX (GFE). SEE PAC UNIT DETAIL, DWG M04.

DUCT PENETRATION THROUGH SOUND WALL TO BE SEALED AIR TIGHT.

EQUIPMENT ROOM (114), AND 2 PANELS IN COMMUNICATIONS ROOM (115).

EDH

x1

8x

8x8

B-12x24

EDH

T

G-3 SLOT

10x6

12"Ø

6x10 x8 x1

12x12 x1

6x12 x1 x1

10x22

EDH

EDH

14x12 18x12

EDH

EDH

9 10 x1

12x12

G-2 SLOT

EDH

12x12

(2)30x22

30x12

45°dn

B-12x24

10x8

O/A

(TYP)

O/A

48"W x 48"H LOUVER

WITH 36" DEEP PLENUM

(BOTTOM @ 12'-0" AFF)

24x18

36x18

24x18

(18x18)

AD

TYPICAL 2 PLACES)

(BOTTOM @ 12'-0" AFF-

48"W x 48"H RELIEF LOUVER

A-12"Ø

B-12x24

M04

8x6 x1 x1

H-2 SLOT

SERV VEST

8x8

H-4 SLOT8"Ø

T

(TYPICAL 2)

8"Ø

(TYP)

EHG-3 SLOT

MIC

MULTI-PURPOSE

OFFICE

NWR

106A

CORRIDOR

8"Ø

G-3 SLOT

(TYP)

8"Ø

H-3 SLOT

G-2 SLOT

G-2 SLOT

G-3 SLOT

B-12x24

G-2 SLOT

TT

T

T

(TYPICAL 3)

(TYPICAL 4)

8"Ø

8"Ø

8"Ø x1

EF

8"Ø

12x12

CORRIDOR

WOMEN

MEN

F-10x10 x8 x8

(BOTTOM @

8'-0" AFF)

F-10x10

C-6x6

G-3 SLOT

9'-0" AFF)

(BOTTOM @

C-8x6

D-10x10

E-10x10

E-10x10

D-18x18

G-2 SLOT

G-2 SLOT

245°DN

x1 x6 x6

EH

8"Ø

8"Ø

(TYPICAL 2)

8x

AHU-3

BOTH SIDES)

7'-4" AFF

(BOTTOM @

(TYPICAL 5)

B-24x24

READY ROOM

ELEC TECH

B-24x24

(TYPICAL 4)

G-3 SLOT

7'-4" AFF)

(BOTTOM @

48x14

I-24x24

D-30x12

8"Ø

M04

44x15

5/8"-RL

1 5/8"-RS

(GFE)

PAC

TF

10x12 10x10 8x6

(TYPICAL 7)

8"Ø

(TYP)

(TYPICAL 7)

H

T

T

G-3 SLOT

A-10"Ø

OPERATIONS

COATS

HVAC PLAN NOTES

STORAGE

NORTH

BUILDING

SCALE: 1/4"=1'-0"

HVAC PLAN

0 2' 4' 8' 12'

SCALE: 1/4"=1'-0"

R L ANDREWS

BIRMINGHAM, ALABAMA

HVAC PLAN

FD

SP

KANSAS CITY, MO.

U.S.A.

ARCHITECTS, P.A.

GOULD EVANS

SERVICES CONTRACTOR

PROGRAM MANAGEMENT

PROJECT NO.

WFO / NEXRAD PROGRAM

DESCRIPTION OF REVISIONFDI

APPROVED APPROVED

ACTR/COTR

BY

CHECKED

BY

PREPAREDDATENO.

SPECIAL ENGINEERING PROGRAM OFFICE (SEPO)

WEATHER FORECAST OFFICE

REV.CLIN.DWG. NO.SIZE

ACOTR./COTR.

ENGR/PROJ. MGR.

SUP'V. ENGR.

CHECKED

DRAWN

S P

EC

IA

L

EN

GIN

EERING PROGRAM

OFF

ICE

N A T

IO

N

AL

OC

EANIC

ND TMOSPH

ER

ICA

A

AD

M

IN

IS

T R A T

IO

N

EQUIPMENT

COMM

ELEC

RCPTN

G-2 SLOT

MD

PROVIDE PORTABLE COMPUTER TABLE WITH CASTERS AND AN ADDITIONAL

25FT OF WIRE COILED BELOW ACCESS FLOOR.

DUCTWORK SHALL BE WRAPPED FROM AIR HANDLING UNIT TO A POINT18

PROVIDE TEMPERATURE

SENSOR WITH INSULATED

SUB-BASE

x2

24x18

(BOTTOM @ 12'-0" AFF)

WITH 12" DEEP PLENUM

48"W x 48"H LOUVER

"PANTS CONNECTION"

6x8

A-8"Ø

A-8"Ø

12x12 AD

MD

18 "PANTS CONNECTION"

30x22

12x12 AD

(TYPICAL 2)

(TYPICAL 2)

BDD

x2

EDH

DOWNSTREAM AS INDICATED ON DRAWINGS.

20x22 18x20 16x16 14x12 x1

A-10"Ø

S MINO

D FULCHER

BLR/TLS

JAB

CO01

449404- 5 M03 CO 1

1 10/7/94 SJL D FULCHER BLR/TLS JAB REVISED PER AS-BUILT CONDITIONS

9:

S

JL

4=

1' K

C C O M

Model