KCCOM031.pdf
PDF 127 KB Posted
- Solicitation number
- NWWP4000-19-00072MWH
About this file
Mechanical prints for the two locations
View the file
Other files
| File | Type | Posted |
|---|---|---|
| CRP_WFO_Mech_dwgs.pdf | ||
| KCDME062.pdf | ||
| KCCOM041.pdf | ||
| KCCOM051.pdf | ||
| KCDME042.pdf | ||
| KCDME032.pdf | ||
| KCCOM062.pdf | ||
| KCDME051.pdf | ||
| BMX_WFO_Mech_dwgs.pdf | ||
| 19-00072_-_SF_18_Quote_Form.doc | DOC document | |
| 19-00072_-_SOW-CRP_HVAC_Controls_Replacement_Updated_Rev_4Mar19_-_FBO.pdf | ||
| 19-00072_-_SOW-BMX_HVAC_Controls_November_1,_2018_Rev_4Mar19_-_FBO.pdf | ||
| Calera_AL_SCLS.pdf | ||
| Corpus_Christi_TX_SCLS.pdf |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SEAL ALL DUCT JOINTS WATERTIGHT.
CONNECT 8"Ø FLEXIBLE DUCT TO 12x12x24 PLENUM BOX IN SOFFIT.
BOTTOM OF GRILLES IN SOFFIT TO BE @ 7'-6" AFF (TYPICAL 3 PLACES).
CEILING PLAN (DWG A06).
COORDINATE DIFFUSER LOCATIONS IN LAY-IN CEILING WITH THE REFLECTED
ACCESS OPENING IN CEILING (SEE ARCHITECTURAL DWG A06).
FOR CONTINUATION, SEE MECHANICAL EQUIPMENT SPACE PLAN, DWG M04.
PROVIDE PIPE SLEEVES WITH MECHANICAL SEAL FOR REFRIGERANT PIPES.
FLEXIBLE REFRIGERANT PIPE CONNECTION.
REFRIGERANT LINE SUPPORT. SECURE CHANNELS TO SLAB WITH EXPANSION ANCHORS.
PROVIDE CHANNELS 4" HIGH WITH TUBING CLIPS WITH RUBBER ISOLATORS FOR
8"Ø MD
PAC
(GFE)
(BOTTOM @
10'-0" AFF)
2 MOD
MOD T
AHU-1
7/8"-RL
2 1/8"-RS
2 1/8"-RS
7/8"-RL
AHU-2
R A B
O O T x1
B-12x24
R A B
O O T
(TYPICAL 2)
8x
EDH
45°up
EQUIPMENT SPACE)
COMPONENTS (IN MECHANICAL
TO TEMPERATURE CONTROL
MDMD
MD
MD
MD
(T
YP
4' 0"
17TERMINAL
TEMP CONTROL
8x8
MD
MD MD
MD
x2
C
(GFE)
ACU
ACU
ACU
(2 CIRCUITS PER UNIT)
7/8" HG, 1/2" RL
2 (GFE)
C
M04
M04
M04
M04
D
E
F
C
A
B
VEST
WAITING
FILE/COPY
JAN
1 2 4 6 7
F
E
D
C
B
A
7654321
6x6
EDH
M04
BOOT UP 12" (TYPICAL 2)
24x48 BOOT - TURN
BDD
BDD
AD
(18x18)
T
(2)36x24
36x24
8"Ø
18x12 OP'NG (TYP 2)
E-12x12
E-12x12
C-12x12
PROVIDE 14 PERFORATED FLOOR PANELS. INSTALL 12 PANELS IN
(TYPICAL 2)
E-30x24 x1
6x
8x
18x12
8x6
PROVIDE GRILLE OF ALUMINUM CONSTRUCTION.
ANCHOR CONDENSING UNITS TO SLAB.
CONCRETE HOODS (SEE STRUCTURAL DWG S04).
ALARM AND INDICATOR LIGHTS PANEL.
REMOTE CONTROL BOX (GFE). SEE PAC UNIT DETAIL, DWG M04.
DUCT PENETRATION THROUGH SOUND WALL TO BE SEALED AIR TIGHT.
EQUIPMENT ROOM (114), AND 2 PANELS IN COMMUNICATIONS ROOM (115).
EDH
x1
8x
8x8
B-12x24
EDH
T
G-3 SLOT
10x6
12"Ø
6x10 x8 x1
12x12 x1
6x12 x1 x1
10x22
EDH
EDH
14x12 18x12
EDH
EDH
9 10 x1
12x12
G-2 SLOT
EDH
12x12
(2)30x22
30x12
45°dn
B-12x24
10x8
O/A
(TYP)
O/A
48"W x 48"H LOUVER
WITH 36" DEEP PLENUM
(BOTTOM @ 12'-0" AFF)
24x18
36x18
24x18
(18x18)
AD
TYPICAL 2 PLACES)
(BOTTOM @ 12'-0" AFF-
48"W x 48"H RELIEF LOUVER
A-12"Ø
B-12x24
M04
8x6 x1 x1
H-2 SLOT
SERV VEST
8x8
H-4 SLOT8"Ø
T
(TYPICAL 2)
8"Ø
(TYP)
EHG-3 SLOT
MIC
MULTI-PURPOSE
OFFICE
NWR
106A
CORRIDOR
8"Ø
G-3 SLOT
(TYP)
8"Ø
H-3 SLOT
G-2 SLOT
G-2 SLOT
G-3 SLOT
B-12x24
G-2 SLOT
TT
T
T
(TYPICAL 3)
(TYPICAL 4)
8"Ø
8"Ø
8"Ø x1
EF
8"Ø
12x12
CORRIDOR
WOMEN
MEN
F-10x10 x8 x8
(BOTTOM @
8'-0" AFF)
F-10x10
C-6x6
G-3 SLOT
9'-0" AFF)
(BOTTOM @
C-8x6
D-10x10
E-10x10
E-10x10
D-18x18
G-2 SLOT
G-2 SLOT
245°DN
x1 x6 x6
EH
8"Ø
8"Ø
(TYPICAL 2)
8x
AHU-3
BOTH SIDES)
7'-4" AFF
(BOTTOM @
(TYPICAL 5)
B-24x24
READY ROOM
ELEC TECH
B-24x24
(TYPICAL 4)
G-3 SLOT
7'-4" AFF)
(BOTTOM @
48x14
I-24x24
D-30x12
8"Ø
M04
44x15
5/8"-RL
1 5/8"-RS
(GFE)
PAC
TF
10x12 10x10 8x6
(TYPICAL 7)
8"Ø
(TYP)
(TYPICAL 7)
H
T
T
G-3 SLOT
A-10"Ø
OPERATIONS
COATS
HVAC PLAN NOTES
STORAGE
NORTH
BUILDING
SCALE: 1/4"=1'-0"
HVAC PLAN
0 2' 4' 8' 12'
SCALE: 1/4"=1'-0"
R L ANDREWS
BIRMINGHAM, ALABAMA
HVAC PLAN
FD
SP
KANSAS CITY, MO.
U.S.A.
ARCHITECTS, P.A.
GOULD EVANS
SERVICES CONTRACTOR
PROGRAM MANAGEMENT
PROJECT NO.
WFO / NEXRAD PROGRAM
DESCRIPTION OF REVISIONFDI
APPROVED APPROVED
ACTR/COTR
BY
CHECKED
BY
PREPAREDDATENO.
SPECIAL ENGINEERING PROGRAM OFFICE (SEPO)
WEATHER FORECAST OFFICE
REV.CLIN.DWG. NO.SIZE
ACOTR./COTR.
ENGR/PROJ. MGR.
SUP'V. ENGR.
CHECKED
DRAWN
S P
EC
IA
L
EN
GIN
EERING PROGRAM
OFF
ICE
N A T
IO
N
AL
OC
EANIC
ND TMOSPH
ER
ICA
A
AD
M
IN
IS
T R A T
IO
N
EQUIPMENT
COMM
ELEC
RCPTN
G-2 SLOT
MD
PROVIDE PORTABLE COMPUTER TABLE WITH CASTERS AND AN ADDITIONAL
25FT OF WIRE COILED BELOW ACCESS FLOOR.
DUCTWORK SHALL BE WRAPPED FROM AIR HANDLING UNIT TO A POINT18
PROVIDE TEMPERATURE
SENSOR WITH INSULATED
SUB-BASE
x2
24x18
(BOTTOM @ 12'-0" AFF)
WITH 12" DEEP PLENUM
48"W x 48"H LOUVER
"PANTS CONNECTION"
6x8
A-8"Ø
A-8"Ø
12x12 AD
MD
18 "PANTS CONNECTION"
30x22
12x12 AD
(TYPICAL 2)
(TYPICAL 2)
BDD
x2
EDH
DOWNSTREAM AS INDICATED ON DRAWINGS.
20x22 18x20 16x16 14x12 x1
A-10"Ø
S MINO
D FULCHER
BLR/TLS
JAB
CO01
449404- 5 M03 CO 1
1 10/7/94 SJL D FULCHER BLR/TLS JAB REVISED PER AS-BUILT CONDITIONS
9:
S
JL
4=
1' K
C C O M
Model
File details come from the government source that posted it.