This document appears to be an architectural and engineering design package for a single-family housing prototype for the National Park Service (NPS). The package includes detailed drawings, specifications, and construction assembly details for a 1-story, 3-bedroom, 2-bathroom housing unit. The design allows for various building options and materials to be selected by the park, such as different roofing, siding, and garage configurations. The drawings include floor plans, elevations, sections, details, and accessibility compliance requirements. This appears to be part of a larger initiative by the NPS to develop standardized housing prototypes for use across multiple park locations.

The related federal contract opportunity is for a Multiple Award Task Order Contract for design-build services to construct NPS employee housing. This pre-solicitation notice indicates the NPS is seeking qualified firms to provide design-build services for new housing units. The contract will likely be awarded to multiple firms through an indefinite delivery, indefinite quantity (IDIQ) contract vehicle. Key details such as the response date, award date, and any set-asides are not provided in the information given.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AutoCAD SHX Text

UNIT MIX & AREA CALCULATIONS:

AutoCAD SHX Text

1. CALCULATIONS FOR THE GROSS AREAS ARE BASED ON THE OUTSIDE FACE OF CALCULATIONS FOR THE GROSS AREAS ARE BASED ON THE OUTSIDE FACE OF STUDS AT EXTERIOR WALLS, AND TO THE GRID LINE ON DEMISING WALLS. AT EXTERIOR WALLS, AND TO THE GRID LINE ON DEMISING WALLS. EXTERIOR WALLS, AND TO THE GRID LINE ON DEMISING WALLS. THE NET AREAS ARE BASED ON FINISH FACE TO FINISH FACE OF WALLS. 2. COMMON AREAS INCLUDE STAIRS, CORRIDORS AND RISER ROOM. COMMON AREAS INCLUDE STAIRS, CORRIDORS AND RISER ROOM.

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text

GROSS BUILDING SF

AutoCAD SHX Text

UNIT TYPE

AutoCAD SHX Text

UNIT AREA (GROSS)

AutoCAD SHX Text

LEVEL

AutoCAD SHX Text

LEVEL 01

AutoCAD SHX Text

3 BEDROOMS BEDROOMS S & 2 BATHROOMS BATHROOMSBATHROOMSROOMSS

AutoCAD SHX Text

1,568.00 SF SF

AutoCAD SHX Text

TOTAL:

AutoCAD SHX Text

UNIT AREA (NET)

AutoCAD SHX Text

1,491.84 SF SF

AutoCAD SHX Text

1,568.00 SF SF

AutoCAD SHX Text

1,568.00 SF SF

AutoCAD SHX Text

1. THESE DRAWINGS ARE TO BE USED TO DEVELOP CONSTRUCTION DOCUMENTS THESE DRAWINGS ARE TO BE USED TO DEVELOP CONSTRUCTION DOCUMENTS WITH SITE-SPECIFIC REQUIREMENTS TO BE DETERMINED DURING THE CD PHASE OF DESIGN. 2. A/E OF RECORD IS RESPONSIBLE FOR ALL CHANGES WITHIN THESE DOCUMENTS A/E OF RECORD IS RESPONSIBLE FOR ALL CHANGES WITHIN THESE DOCUMENTS TO MEET THE NPS - DSC WORKFLOW REQUIREMENTS, ACCESSIBILITY REQUIREMENTS, ALL LOCAL CODE REQUIREMENTS & ANY OTHER DESIGN REQUIREMENTS NEEDED FOR THE SITE SPECIFIC REQUIREMENTS OF THE PROJECT. .

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

STATE

AutoCAD SHX Text

NATIONAL PARK SERVICE

AutoCAD SHX Text

DENVER SERVICE CENTER

AutoCAD SHX Text

REGION

AutoCAD SHX Text

COUNTY

AutoCAD SHX Text

DEPARTMENT OF THE INTERIOR

AutoCAD SHX Text

UNITED STATES

AutoCAD SHX Text

LOCATION WITHIN PARK

AutoCAD SHX Text

NAME OF PARK

AutoCAD SHX Text

TITLE OF DRAWING

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text N/A

AutoCAD SHX Text N/A

AutoCAD SHX Text

OF

AutoCAD SHX Text

PKG.

AutoCAD SHX Text

NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

HOUSING PROTOTYPE DESIGN CATALOG

AutoCAD SHX Text

QUALITY DESIGN CERTIFICATION

AutoCAD SHX Text

OR

AutoCAD SHX Text

OR

AutoCAD SHX Text Development (Title I)

AutoCAD SHX Text Prepared in Accordance with Design

AutoCAD SHX Text by Design Development (Title I)

AutoCAD SHX Text Construction Drawing Not Preceded

AutoCAD SHX Text Approved by Superintendent on

AutoCAD SHX Text Variance from Design Development (Title I)

AutoCAD SHX Text Project Manager

AutoCAD SHX Text Drawing No.

AutoCAD SHX Text Date

AutoCAD SHX Text Date

AutoCAD SHX Text Sheet

AutoCAD SHX Text Mark

AutoCAD SHX Text

REVISION

AutoCAD SHX Text Date

AutoCAD SHX Text Initial

AutoCAD SHX Text

HOUSING PROTYPE DESIGN CATALOG

AutoCAD SHX Text N/A

AutoCAD SHX Text N/A

AutoCAD SHX Text N/A

AutoCAD SHX Text

NATIONAL PARK SERVICE

AutoCAD SHX Text

BUILDING 9

AutoCAD SHX Text

AutoCAD SHX Text 149091

AutoCAD SHX Text Plotted: 11/4/2020 1:34 PM File Location: Y:\Shared\Projects\national park service\33040-housing waso\40.0-cadd\WASO\DRAWINGS\building 9\GEN\COVER SHEET.dwg 11/4/2020 1:34 PM File Location: Y:\Shared\Projects\national park service\33040-housing waso\40.0-cadd\WASO\DRAWINGS\building 9\GEN\COVER SHEET.dwg File Location: Y:\Shared\Projects\national park service\33040-housing waso\40.0-cadd\WASO\DRAWINGS\building 9\GEN\COVER SHEET.dwg Y:\Shared\Projects\national park service\33040-housing waso\40.0-cadd\WASO\DRAWINGS\building 9\GEN\COVER SHEET.dwg

AutoCAD SHX Text

HOUSING PROTOTYPE DESIGN CATALOG

AutoCAD SHX Text BUILDING #9 - SINGLE FAMILY HOUSE 9 - SINGLE FAMILY HOUSE - SINGLE FAMILY HOUSE SINGLE FAMILY HOUSE 1 STORY 3 BEDROOMS BEDROOMS S 2 BATHROOMSBATHROOMSS

AutoCAD SHX Text

SHEET LIST

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

SUB SHEET

AutoCAD SHX Text

TITLE OF SHEET

AutoCAD SHX Text

GENERAL

AutoCAD SHX Text

AutoCAD SHX Text

COVER SHEET

AutoCAD SHX Text

AutoCAD SHX Text G1

AutoCAD SHX Text

ABBREVIATIONS SYMBOLS AND NOTES

AutoCAD SHX Text

AutoCAD SHX Text G2

AutoCAD SHX Text

GENERAL KEYNOTES - ARCHITECTURAL & STRUCTURAL

AutoCAD SHX Text

AutoCAD SHX Text G3

AutoCAD SHX Text

GENERAL KEYNOTES - MEP

AutoCAD SHX Text

AutoCAD SHX Text G4

AutoCAD SHX Text

CONSTRUCTION ASSEMBLIES

AutoCAD SHX Text

AutoCAD SHX Text G5

AutoCAD SHX Text

ACCESSIBILITY STANDARDS DIMENSIONS

AutoCAD SHX Text

ARCHITECTURAL

AutoCAD SHX Text

AutoCAD SHX Text A1

AutoCAD SHX Text

CODE SUMMARY

AutoCAD SHX Text

AutoCAD SHX Text A2

AutoCAD SHX Text

SCHEDULES

AutoCAD SHX Text

AutoCAD SHX Text A3

AutoCAD SHX Text

FLOOR PLAN

AutoCAD SHX Text

AutoCAD SHX Text A4A

AutoCAD SHX Text

ROOF PLAN - BASELINE

AutoCAD SHX Text

AutoCAD SHX Text A4B

AutoCAD SHX Text

ROOF PLAN - OPTION

AutoCAD SHX Text

AutoCAD SHX Text A5A

AutoCAD SHX Text

BUILDING ELEVATIONS - BASELINE

AutoCAD SHX Text

AutoCAD SHX Text A5B

AutoCAD SHX Text

BUILDING ELEVATIONS - OPTION

AutoCAD SHX Text

AutoCAD SHX Text A6A

AutoCAD SHX Text

BUILDING SECTIONS - BASELINE

AutoCAD SHX Text

AutoCAD SHX Text A6B

AutoCAD SHX Text

BUILDING SECTIONS - OPTION

AutoCAD SHX Text

AutoCAD SHX Text A7A

AutoCAD SHX Text

WALL SECTIONS - BASELINE

AutoCAD SHX Text

AutoCAD SHX Text A7B

AutoCAD SHX Text

WALL SECTIONS - OPTION

AutoCAD SHX Text

AutoCAD SHX Text A8

AutoCAD SHX Text

ENLARGED PLANS & INTERIOR ELEVATIONS

AutoCAD SHX Text

AutoCAD SHX Text A9

AutoCAD SHX Text

REFECTED CEILING PLAN

AutoCAD SHX Text

AutoCAD SHX Text A10

AutoCAD SHX Text

EXTERIOR DETAILS

AutoCAD SHX Text

AutoCAD SHX Text A11

AutoCAD SHX Text

EXTERIOR DETAILS

AutoCAD SHX Text

AutoCAD SHX Text A12A

AutoCAD SHX Text

ROOF DETAILS - BASELINE

AutoCAD SHX Text

AutoCAD SHX Text A12B

AutoCAD SHX Text

ROOF DETAILS - OPTION

AutoCAD SHX Text

AutoCAD SHX Text A13

AutoCAD SHX Text

INTERIOR DETAILS

AutoCAD SHX Text

AutoCAD SHX Text A14A

AutoCAD SHX Text

GARAGE - OPTION A

AutoCAD SHX Text

AutoCAD SHX Text A14B

AutoCAD SHX Text

GARAGE - OPTION B

AutoCAD SHX Text

AutoCAD SHX Text A15

AutoCAD SHX Text

GARAGE DETAILS - OPTION

AutoCAD SHX Text

AutoCAD SHX Text A16

AutoCAD SHX Text

PORCH COVER & DECK OPTION

AutoCAD SHX Text

AutoCAD SHX Text A17

AutoCAD SHX Text

RAISED WOOD DECK - OPTION

AutoCAD SHX Text

AutoCAD SHX Text A18A

AutoCAD SHX Text

DETACHED STORAGE UNIT PLANS - OPTION A

AutoCAD SHX Text

AutoCAD SHX Text A18B

AutoCAD SHX Text

DETACHED STORAGE UNIT PLANS - OPTION B

AutoCAD SHX Text

AutoCAD SHX Text A19

AutoCAD SHX Text

DETACHED STORAGE UNIT DETAILS - OPTION

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

SUB SHEET

AutoCAD SHX Text

TITLE OF SHEET

AutoCAD SHX Text

STRUCTURAL

AutoCAD SHX Text

AutoCAD SHX Text S1

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

AutoCAD SHX Text S2A

AutoCAD SHX Text

FOUNDATION PLAN - BASELINE

AutoCAD SHX Text

AutoCAD SHX Text S2B

AutoCAD SHX Text

FOUNDATION PLAN - OPTION

AutoCAD SHX Text

AutoCAD SHX Text S3A

AutoCAD SHX Text

ROOF FRAMING PLAN - BASELINE

AutoCAD SHX Text

AutoCAD SHX Text S3B

AutoCAD SHX Text

ROOF FRAMING PLAN - OPTION

AutoCAD SHX Text

AutoCAD SHX Text S4A

AutoCAD SHX Text

FOUNDATION DETAILS - BASELINE

AutoCAD SHX Text

AutoCAD SHX Text S4B

AutoCAD SHX Text

FOUNDATION DETAILS - OPTION

AutoCAD SHX Text

AutoCAD SHX Text S5A

AutoCAD SHX Text

FRAMING DETAILS - BASELINE

AutoCAD SHX Text

AutoCAD SHX Text S5B

AutoCAD SHX Text

FRAMING DETAILS - OPTION

AutoCAD SHX Text

AutoCAD SHX Text S6A

AutoCAD SHX Text

GARAGE PLANS - OPTION A

AutoCAD SHX Text

AutoCAD SHX Text S6B

AutoCAD SHX Text

GARAGE PLANS - OPTION B

AutoCAD SHX Text

AutoCAD SHX Text S7A

AutoCAD SHX Text

DETACHED STORAGE PLAN - OPTION A

AutoCAD SHX Text

AutoCAD SHX Text S7B

AutoCAD SHX Text

DETACHED STORAGE PLAN - OPTION B

AutoCAD SHX Text

MEP

AutoCAD SHX Text

AutoCAD SHX Text M1

AutoCAD SHX Text

MECHANICAL & PLUMBING SYSBOLS & ABBREVIATIONS

AutoCAD SHX Text

AutoCAD SHX Text M2

AutoCAD SHX Text

FLOOR PLAN HVAC

AutoCAD SHX Text

AutoCAD SHX Text M3

AutoCAD SHX Text

FLOOR PLAN PLUMBING WASTE

AutoCAD SHX Text

AutoCAD SHX Text M4

AutoCAD SHX Text

FLOOR PLAN WATER & FIRE PROTECTION

AutoCAD SHX Text

AutoCAD SHX Text M5

AutoCAD SHX Text

MECHANICAL & PLUMBING SCHEDULES

AutoCAD SHX Text

AutoCAD SHX Text M6

AutoCAD SHX Text

MECHANICAL & PLUMBING SCHEDULES

AutoCAD SHX Text

AutoCAD SHX Text M7

AutoCAD SHX Text

MECHANICAL & PLUMBING DETAILS

AutoCAD SHX Text

AutoCAD SHX Text M8

AutoCAD SHX Text

ONE LINE DIAGRAMS

AutoCAD SHX Text

AutoCAD SHX Text M9

AutoCAD SHX Text

GARAGE FLOOR PLAN HVAC

AutoCAD SHX Text

AutoCAD SHX Text M10

AutoCAD SHX Text

GARAGE FLOOR PLAN PLUMBING WASTE

AutoCAD SHX Text

AutoCAD SHX Text M11

AutoCAD SHX Text

GARAGE FLOOR PLAN WATER & FIRE PROTECTION

AutoCAD SHX Text

AutoCAD SHX Text M12

AutoCAD SHX Text

DETACHED STORAGE UNIT HAVC PLAN - OPTION

AutoCAD SHX Text

AutoCAD SHX Text E1

AutoCAD SHX Text

ELECTRICAL SYMBOLS

AutoCAD SHX Text

../MEP/E2 FLRPLAN ELECTRICAL POWER.DWG

AutoCAD SHX Text E2

../MEP/E2 FLRPLAN ELECTRICAL POWER.DWG

AutoCAD SHX Text

FLOOR PLAN ELECTRICAL POWER

AutoCAD SHX Text

AutoCAD SHX Text E3

AutoCAD SHX Text

SINGLE LINE DIAGRAM

AutoCAD SHX Text

../MEP/E4 FLRPLAN ELECTRICAL LIGHTING.DWG

AutoCAD SHX Text E4

../MEP/E4 FLRPLAN ELECTRICAL LIGHTING.DWG

AutoCAD SHX Text

FLOOR PLAN ELECTRICAL LIGHTING

AutoCAD SHX Text

AutoCAD SHX Text E5

AutoCAD SHX Text

ELECTRICAL SCHEDULES

AutoCAD SHX Text

AutoCAD SHX Text E6

AutoCAD SHX Text

ELECTRICAL DETAILS

AutoCAD SHX Text

../MEP/E7 FLRPLAN GARAGE - POWER.DWG

AutoCAD SHX Text E7

../MEP/E7 FLRPLAN GARAGE - POWER.DWG

AutoCAD SHX Text

GARAGE FLOOR PLAN ELECTRICAL POWER - OPTION

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

SUB SHEET

AutoCAD SHX Text

TITLE OF SHEET

AutoCAD SHX Text

../MEP/E8 FLRPLAN GARAGE - LIGHTING.DWG

AutoCAD SHX Text E8

../MEP/E8 FLRPLAN GARAGE - LIGHTING.DWG

AutoCAD SHX Text

GARAGE FLOOR PLAN ELECTRICAL LIGHTING - OPTION

AutoCAD SHX Text

AutoCAD SHX Text E9

AutoCAD SHX Text

DETACHED STORAGE UNIT POWER PLAN - OPTION

AutoCAD SHX Text

AutoCAD SHX Text E10

AutoCAD SHX Text

DETACHED STORAGE UNIT LIGHTING PLAN - OPTION

AutoCAD SHX Text

100% DESIGN DEVELOPMENT NOT FOR CONSTRUCTION

100% FINAL DESIGN DEVELOPMENTDESIGN DEVELOPMENT

PLACE NOTHING HERE

TITLEBLOCK AREA (22" X 34" FULL MVIEW)

AutoCAD SHX Text & AND AND @ AT AT # NUMBER NUMBER ±PLUS OR MINUS ABA ARCHITECTURAL BARRIERS ACT ARCHITECTURAL BARRIERS ACT ADDL ADDITIONAL ADDITIONAL AFF ABOVE FINISH FLOOR ABOVE FINISH FLOOR AHJ AUTHORITY HAVING JURISDICTION AUTHORITY HAVING JURISDICTION ALUM ALUMINUM ALUMINUM BD BOARD BOARD BED BEDROOM BEDROOM BLDG BUILDING BUILDING BLKG BLOCKING BLOCKING B.O. BOTTOM OF BOTTOM OF CENTERLINE CENTERLINE CB CEMENTITIOUS BOARD CEMENTITIOUS BOARD CJ CONTROL JOINT CONTROL JOINT CLG CEILING CEILING CL CLOSET CLOSET CLR CLEAR(ANCE) CLEAR(ANCE) CMU CONCRETE MASONRY UNIT(S) CONCRETE MASONRY UNIT(S) C.O. CONTRACTING OFFICER CONTRACTING OFFICER COL(S) COLUMN(S) COLUMN(S) CONC CONCRETE CONCRETE CONT CONTINUOUS CONTINUOUS CONSTR CONSTRUCTION CONSTRUCTION CORR CORRIDOR CORRIDOR CPT CARPET CARPET CT CERAMIC TILE CERAMIC TILE D DRYER DRYER DIA DIAMETER DIAMETER DIM DIMENSION DIMENSION DR DOOR DOOR DS DOWNSPOUT DOWNSPOUT DW DISHWASHER DISHWASHER

AutoCAD SHX Text EA EACH EACH EL ELEVATION ELEVATION ELEC ELECTRIC(AL) ELECTRIC(AL) EQ EQUAL EQUAL EQUIP EQUIPMENT EQUIPMENT EXT EXTERIOR EXTERIOR FD FLOOR DRAIN FLOOR DRAIN FE FIRE EXTINGUISHER FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FIRE EXTINGUISHER CABINET FF FINISH FLOOR FINISH FLOOR FG FIBERGLASS DRAIN PAN FIBERGLASS DRAIN PAN FIG FIGURE FIGURE FIN FINISH(ED) FINISH(ED) FLR FLOOR FLOOR FN FURNACE FURNACE F.O. FACE OF FACE OF FOS FACE OF STUD, SLAB FACE OF STUD, SLAB FRP FIBER REINFORCED PLASTIC FIBER REINFORCED PLASTIC GA GAUGE, GYPSUM ASSOCIATION GAUGE, GYPSUM ASSOCIATION GALV GALVANIZE(D) GALVANIZE(D) GB GRAB BAR GRAB BAR GYP GYPSUM GYPSUM GWB GYPSUM WALL BOARD GYPSUM WALL BOARD HM HOLLOW METAL HOLLOW METAL HR HOUR HOUR HVAC HEATING, VENTILATION, AND HEATING, VENTILATION, AND AIR CONDITIONING IBC INTERNATIONAL BUILDING CODE INTERNATIONAL BUILDING CODE ICC INTERNATIONAL CODE COUNCIL INTERNATIONAL CODE COUNCIL INFO INFORMATION INFORMATION INT INTERIOR INTERIOR IRC INTERNATIONAL RESIDENTIAL CODE INTERNATIONAL RESIDENTIAL CODE LIN LINEN LINEN MANUF MANUFACTURERMANUFACTURER

AutoCAD SHX Text MAX MAXIMUM MAXIMUM MECH MECHANICAL MECHANICAL MEP MECHANICAL, ELECTRICAL AND MECHANICAL, ELECTRICAL AND PLUMBING ENGINEERING MDF MEDIUM DENSITY FIBERBOARD MEDIUM DENSITY FIBERBOARD MIL MILLIMETER MILLIMETER MIN MINIMUM MINIMUM MIRR MIRROR(ED) MIRROR(ED) MTL METAL METAL (N) NEW NEW NA NOT APPLICABLE NOT APPLICABLE NFPA NATIONAL FIRE PROTECTION NATIONAL FIRE PROTECTION ASSOCIATION NO NUMBER NUMBER NPS NATIONAL PARK SERVICE NATIONAL PARK SERVICE O.C. ON CENTER ON CENTER OFOI OWNER FURNISH/OWNER INSTALL OWNER FURNISH/OWNER INSTALL OH OVERHEAD OVERHEAD OPP OPPOSITE OPPOSITE OSB ORIENTED STRAND BOARD ORIENTED STRAND BOARD OTS OPEN TO STRUCTURE OPEN TO STRUCTURE PERF PERFORATE(D) PERFORATE(D) PL PLATE, PROPERTY LINE PLATE, PROPERTY LINE PLAM PLASTIC LAMINATE PLASTIC LAMINATE PT PRESSURE TREATED PRESSURE TREATED PTD PAINTED PAINTED PV PHOTOVOLTAIC PHOTOVOLTAIC PVC POLYVINYL CHLORIDE POLYVINYL CHLORIDE RCP REFLECTED CEILING PLAN REFLECTED CEILING PLAN REF REFRIGERATOR, REFERENCE REFRIGERATOR, REFERENCE REQD REQUIRED REQUIRED REV REVERSE(D) REVERSE(D) RO ROUGH OPENING ROUGH OPENING RS RESILIENT SHEET GOODS RESILIENT SHEET GOODS RWB RESILIENT WALL BASERESILIENT WALL BASE

AutoCAD SHX Text ASSEMBLY WINDOW NUMBER DOOR NUMBER KEYNOTE ARCH DETAIL TAGS EXTERIOR ELEVATION INTERIOR ELEVATIONS WALL SECTION BUILDING SECTION CENTERLINE ROOM NAME & NUMBER NORTH ARROW

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A##

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A#

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text #/A##

AutoCAD SHX Text

AutoCAD SHX Text A#

AutoCAD SHX Text

AutoCAD SHX Text A#

AutoCAD SHX Text

%%UROOM NAME

AutoCAD SHX Text

AutoCAD SHX Text

ABBREVIATIONS

AutoCAD SHX Text

SYMBOLS

AutoCAD SHX Text SAMF SELF-ADHERED MEMBRANE SELF-ADHERED MEMBRANE FLASHING SC SOLID CORE SOLID CORE SF SQUARE FEET SQUARE FEET SIM SIMILAR SIMILAR SPEC SPECIFICATION(S) SPECIFICATION(S) STC SOUND TRANSMISSION CLASS SOUND TRANSMISSION CLASS STD STANDARD STANDARD STOR STORAGE STORAGE STRUCT STRUCTURAL STRUCTURAL T TEMPERED, TREAD TEMPERED, TREAD TBD TO BE DETERMINED TO BE DETERMINED TEL TELEPHONE TELEPHONE THK THICK THICK TJI TRUSS JOIST I-JOIST TRUSS JOIST I-JOIST T.O. TOP OF TOP OF TYP TYPICAL TYPICAL UL UNDERWRITER'S LABORATORY UNDERWRITER'S LABORATORY UNO UNLESS NOTED OTHERWISE UNLESS NOTED OTHERWISE UTIL UTILITY UTILITY VRFY VERIFY VERIFY W WASHER WASHER W/ WITH WITH WASO WASHINGTON, D.C. AREA WASHINGTON, D.C. AREA SERVICE OFFICE WD WOOD WOOD WH WATER HEATER WATER HEATER WIN WINDOW WINDOW WR WATER RESISTANT WATER RESISTANT WRB WEATHER RESISTANT BARRIER WEATHER RESISTANT BARRIER W/D WASHER AND DRYERWASHER AND DRYER

AutoCAD SHX Text

1. ALL DIMENSIONS ARE TO THE FACE OF STUD, CENTERLINE OF COLUMNS, FACE OF CONCRETE WALLS, FACE OF CMU WALLS, ALL DIMENSIONS ARE TO THE FACE OF STUD, CENTERLINE OF COLUMNS, FACE OF CONCRETE WALLS, FACE OF CMU WALLS, CENTERLINE OF FIXTURES, AND CENTERLINE OF OPENINGS, UNLESS OTHERWISE NOTED. 2. PROJECT SPECIFIC A/E OF RECORD IS COMPLETELY RESPONSIBLE FOR THIS ENTIRE SET OF PROTOTYPE DRAWINGS AND PROJECT SPECIFIC A/E OF RECORD IS COMPLETELY RESPONSIBLE FOR THIS ENTIRE SET OF PROTOTYPE DRAWINGS AND SPECIFICATIONS TO REVIEW, REVISE, AND ADD AS NEEDED TO DEVELOP A COMPLETED 100% CONSTRUCTION DOCUMENTS INCLUDING SITE WORK FOR EACH SPECIFIC PROJECT. THIS INCLUDES MEETING ALL CURRENT NATIONAL AND LOCAL CODE REQUIREMENTS AS WELL AS NPS WORKFLOW REQUIREMENTS. 3. ALL PENETRATIONS THROUGH WALLS SHALL BE SEALED WITH FIRE STOPPING SYSTEMS AS REQUIRED TO ACHIEVE THE ALL PENETRATIONS THROUGH WALLS SHALL BE SEALED WITH FIRE STOPPING SYSTEMS AS REQUIRED TO ACHIEVE THE RESPECTIVE FIRE-RESISTIVE RATING AND SMOKE SEAL AS REQUIRED BY CODE. SEE SHEET A1 FOR SPECIFIC CODE A1 FOR SPECIFIC CODE FOR SPECIFIC CODE INFORMATION. 4. CONTRACTOR SHALL PROVIDE WOOD BLOCKING AS REQUIRED FOR THE PROPER ANCHORAGE OF ALL WALL ATTACHED ITEMS CONTRACTOR SHALL PROVIDE WOOD BLOCKING AS REQUIRED FOR THE PROPER ANCHORAGE OF ALL WALL ATTACHED ITEMS SUCH AS TOILET ACCESSORIES, WALL-MOUNTED FIXTURES, DOOR STOPS, ETC. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING WORK AND WORKING CONDITIONS AND SHALL VERIFY EXISTING CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING WORK AND WORKING CONDITIONS AND SHALL VERIFY EXISTING CONDITIONS AT THE JOB SITE BEFORE SUBMITTING PROPOSALS. NO CLAIMS FOR EXTRA COMPENSATION FOR WORK THAT COULD HAVE BEEN FORESEEN BY SUCH INSPECTION, WHETHER SHOWN ON CONTRACT DOCUMENTS OR NOT, SHALL BE ACCEPTED OR PAID. 6. VERIFY SIZE, COORDINATE LOCATION, AND CHARACTERISTICS OF ALL WORK AND EQUIPMENT TO BE FURNISHED BEFORE ANY VERIFY SIZE, COORDINATE LOCATION, AND CHARACTERISTICS OF ALL WORK AND EQUIPMENT TO BE FURNISHED BEFORE ANY CONSTRUCTION BEGINS. 7. CONTRACTOR SHALL VERIFY AND COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS FOR MECHANICAL, ELECTRICAL, CONTRACTOR SHALL VERIFY AND COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS FOR MECHANICAL, ELECTRICAL, AND PLUMBING WORK AND EQUIPMENT WITH EACH TRADE. 8. INSTALL METAL TRIM ON ALL GYPSUM BOARD EDGES ABUTTING OTHER MATERIALS AND WHERE GYPSUM BOARD IS STOPPED INSTALL METAL TRIM ON ALL GYPSUM BOARD EDGES ABUTTING OTHER MATERIALS AND WHERE GYPSUM BOARD IS STOPPED SHORT OF OTHER MATERIALS TO FORM A RECESS OR REVEAL. 9. VERIFY THAT REQUIRED OPERATION AND MAINTENANCE CLEARANCES ARE PROVIDED FOR ALL EQUIPMENT ITEMS. INSTALL VERIFY THAT REQUIRED OPERATION AND MAINTENANCE CLEARANCES ARE PROVIDED FOR ALL EQUIPMENT ITEMS. INSTALL ALL ITEMS IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS EXCEPT WHEN IN CONFLICT WITH THE SPECIFICATIONS HEREIN, IN WHICH CASE THE MORE STRINGENT REQUIREMENTS SHALL BE COMPLIED WITH. NOTIFY THE CONTRACTING OFFICER IN WRITING OF ANY CONFLICTS. 10. CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL REQUIRED UTILITY SHUT-DOWNS WITH CONTRACTING OFFICER AND CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL REQUIRED UTILITY SHUT-DOWNS WITH CONTRACTING OFFICER AND PARK POINT OF CONTACT, NOTIFY CONTRACTING OFFICER OF INTENDED SHUTDOWN AT LEAST 48 HOURS PRIOR TO SCHEDULED SHUTDOWN. 11. CONTRACTOR SHALL IMMEDIATELY NOTIFY CONTRACTING OFFICER IF HAZARDOUS MATERIAL IS ENCOUNTERED DURING CONTRACTOR SHALL IMMEDIATELY NOTIFY CONTRACTING OFFICER IF HAZARDOUS MATERIAL IS ENCOUNTERED DURING DEMOLITION OR CONSTRUCTION. REMOVAL AND DISPOSAL OF HAZARDOUS MATERIALS SHALL BE ACCOMPLISHED IN COMPLIANCE WITH STATE REGULATIONS. IT IS NOT ANTICIPATED THAT ASBESTOS OR OTHER HAZARDOUS MATERIALS ARE PRESENT IN THE AREA OF WORK. 12. COORDINATE THE AVAILABILITY AND LOCATION OF RECYCLING DUMPSTER AND TRASH DUMPSTER WITH CONTRACTING OFFICER. COORDINATE THE AVAILABILITY AND LOCATION OF RECYCLING DUMPSTER AND TRASH DUMPSTER WITH CONTRACTING OFFICER. TRASH SHALL BE DISPOSED OF AS REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION (AHJ). 13. IT IS CONTRACTORS RESPONSIBILITY TO REMOVE, PROTECT AND SAFELY STORE FIXTURES AND/OR EQUIPMENT AS NOTED IN IT IS CONTRACTORS RESPONSIBILITY TO REMOVE, PROTECT AND SAFELY STORE FIXTURES AND/OR EQUIPMENT AS NOTED IN PLANS AND SPECIFICATIONS. 14. THESE DRAWINGS ALLOW THE GENERAL CONTRACTOR THE OPTION TO PRICE AND BUILD BY EITHER PRE-MANUFACTURER THESE DRAWINGS ALLOW THE GENERAL CONTRACTOR THE OPTION TO PRICE AND BUILD BY EITHER PRE-MANUFACTURER CONSTRUCTION OR ON-SITE STICK BUILT CONSTRUCTION. 15. MODULAR CONSTRUCTION: MODULAR CONSTRUCTION: WHERE MODULAR CONSTRUCTION IS USED, MODULES SHALL BE PROTECTED FROM THE WEATHER BY BEING PERMANENTLY COVERED WITH SLOPED WOOD SHEATHING CAPPED WITH ICE & WATER SHIELD. NO PENETRATIONS SHALL BE PERMITTED DURING STORAGE OR SHIPMENT. PROVIDE TRANSMITTAL OUTLINING PLANNED PROCEDURES FOR APPROVAL BY THE CONTRACTING OFFICER. 16. DURING THE CREATION OF THE 100% CD DOCUMENTS THE AE DESIGN TEAM SHALL COORDINATE ALL FIRE CODE DURING THE CREATION OF THE 100% CD DOCUMENTS THE AE DESIGN TEAM SHALL COORDINATE ALL FIRE CODE REQUIREMENTS WITH WASO (WASHINGTON, D.C. AREA SUPPORT OFFICE), PARK, AND AHJ (AUTHORITY HAVING JURISDICTION) REGARDING THE SPECIFIC LEVEL OF FIRE PROTECTION AND FIRE SUPPORT BASED ON REGIONAL AND PARK NEEDS AND REQUIREMENTS. 17. REFERENCE AND UTILIZE THE 100% DD FIRE MANAGEMENT OFFICER NPS AND AHJ REVIEW COMMENTS. REFERENCE AND UTILIZE THE 100% DD FIRE MANAGEMENT OFFICER NPS AND AHJ REVIEW COMMENTS. FIRE MANAGEMENT OFFICER NPS AND AHJ REVIEW COMMENTS. AND AHJ REVIEW COMMENTS. REVIEW COMMENTS. 18. THE METHODOLOGY FOR ESTABLISHING THE BASELINE CRITERIA FOR EACH OF THE PROTOTYPES AND BUILDING OPTIONS WAS THE METHODOLOGY FOR ESTABLISHING THE BASELINE CRITERIA FOR EACH OF THE PROTOTYPES AND BUILDING OPTIONS WAS BASED ON A SERIES OF CRITERIA WHICH NEED TO BE APPLIED TO ALL PROJECTS. FIRST, THE DOCUMENTS HAVE BEEN DEVELOPED TO MEET EXISTING NPS AND WASO POLICIES. NEXT A BASELINE HAS BEEN SET TO MEET ALL THE APPLICABLE CODES AND ADDITIONALLY MEET NATIONWIDE ACCESSIBILITY REQUIREMENTS. THE PROTOTYPES AND OPTIONS HAVE BEEN DEVELOPED TO PROVIDE FOR FLEXIBLE ADAPTATION TO THE UNIQUE CONDITIONS OF THE LOCATIONS IN WHICH THEY WILL BE CONSTRUCTED, THESE INCLUDE PROGRAMMATIC (HOUSING POLICY AND OCCUPANT NEEDS), CLIMATIC VARIATIONS AND PHYSICAL SITE CONSTRAINTS. FINALLY THE PROTOTYPES AND OPTIONS HAVE BEEN ESTABLISHED TO ENHANCE LIVABILITY AND CONSIDER THE LONG TERM VALUE OF THE PROJECTS. THE DOCUMENTS HAVE BEEN CREATED TO PROVIDE EACH PARK THE ABILITY TO TAKE THE DESIRED PROTOTYPE, SELECT THE DESIRED OPTIONS AND MOVE DIRECTLY TO CONSTRUCTION DOCUMENTS. HOWEVER, THESE DOCUMENTS DO NOT ADDRESS ANY SITE CONDITIONS OR CONSTRAINTS SO THOSE WILL NEED TO BE ADDRESSED BY THE CONSTRUCTION DOCUMENTS DESIGN TEAM, AS WELL AS BY A STRUCTURAL ENGINEER AND NPS, BASED ON PARK NEEDS AND/OR SITE-SPECIFIC CONDITIONS.

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

WFE3

AutoCAD SHX Text

AutoCAD SHX Text 149091

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EF

AutoCAD SHX Text

EF, JP, ML

AutoCAD SHX Text

MN, KJ, MP

AutoCAD SHX Text

BUILDING 9 SINGLE FAMILY HOUSE

AutoCAD SHX Text

NPS HOUSING PROTOTYPE DESIGN CATALOG

AutoCAD SHX Text N/A

AutoCAD SHX Text G1

AutoCAD SHX Text

ABBREVIATIONS SYMBOLS AND NOTES

AutoCAD SHX Text 10/20

AutoCAD SHX Text Plotted: 11/4/2020 1:27 PM File Location: y:\Shared\Projects\national park service\33040-housing waso\40.0-cadd\WASO\DRAWINGS\building 9\GEN\G1 ABBREVIATIONS SYMBOLS AND NOTES.dwg 11/4/2020 1:27 PM File Location: y:\Shared\Projects\national park service\33040-housing waso\40.0-cadd\WASO\DRAWINGS\building 9\GEN\G1 ABBREVIATIONS SYMBOLS AND NOTES.dwg File Location: y:\Shared\Projects\national park service\33040-housing waso\40.0-cadd\WASO\DRAWINGS\building 9\GEN\G1 ABBREVIATIONS SYMBOLS AND NOTES.dwg y:\Shared\Projects\national park service\33040-housing waso\40.0-cadd\WASO\DRAWINGS\building 9\GEN\G1 ABBREVIATIONS SYMBOLS AND NOTES.dwg

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text

TECH. REVIEW:

AutoCAD SHX Text

SUB SHEET NO.

AutoCAD SHX Text

PMIS/PKG NO.

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

TITLE OF SHEET

100% DESIGN DEVELOPMENT NOT FOR CONSTRUCTION

A10 SUBSTRUCTURE

KEYNOTE A1010 STANDARD FOUNDATIONS (SF) STATUS

SF1 SPREAD, STRIP FOOTINGS BASELINE

SF2 PERIMETER DRAIN SYSTEMS OPTION

SF3 CMU STEM WALLS OPTION

KEYNOTE A1020 SPECIAL FOUNDATION REQUIREMENTS (SFR) STATUS

SFR1 CONCRETE CAISSONS, 12" OPTION

SFR2 CONCRETE/WOOD PIERS, 12" OPTION

SFR3 POST/POLE/PAD OPTION

SFR4 HELICAL PIERS OPTION

KEYNOTE A1030 SUBSTRUCTURE (S) STATUS

S1 SLAB ON GRADE, 4" CONCRETE WITH WELDED WIRE MESH BASELINE

S2 CRAWLSPACE, CONCRETE OPTION

B10 SUPERSTRUCTURE

KEYNOTE B1010 FLOOR CONSTRUCTION (FC) STATUS

FC1 WOOD FRAME, TJI CLOSE WEB BASELINE

FC2 WOOD FRAME, TJL OPEN WEB OPTION

KEYNOTE B1030 ROOF CONSTRUCTION (RF) STATUS

RF1 SLOPED ROOF, PRE-MANUFACTURED TRUSSES BASELINE

RF2 INSULATION BASELINE

RF3 FLAT ROOF, TJL OPEN WEB OPTION

KEYNOTE STAIR CONSTRUCTION (SC) STATUS

SC1 PRE-MANUFACTURED WOOD, ENCLOSED BASELINE

SC2

HEAVY TIMBER STRINGERS WITH WOOD TREADS AT DECK,

EXTERIOR CONDITION BASELINE

SC3 WOOD HAND FRAMED OPTION

SC4 STEEL PAN WITH CONCRETE OPTION

SC5 HANDRAIL, PREMANUFACTURED ALUMINUM BASELINE

KEYNOTE B1050 INTERIOR STAIR FINISHES (STF) STATUS

STF1 RESILIENT BASELINE

STF2 CARPET BY PARK

B20 EXTERIOR CLOSURE

KEYNOTE B2010 EXTERIOR WALL CONSTRUCTION (WE) STATUS

WE1A WOOD FRAME CONSTRUCTION ONSITE, 2x BASELINE

WE1B PREMANUFACTURED HOUSING OFF-SITE OPTION

WE2 STRUCTURAL INSULATED PANELS (SIP) OPTION

KEYNOTE B2015 EXTERIOR WALLS SUBSTRATE & INSULATION (WS) STATUS

WS1 1/2" OSB SHEATHING BASELINE

WS2 WEATHER-RESISTANT BARRIER BASELINE

WS3 WALL INSULATION, R21 BASELINE

WS4 5/8" PLYWOOD OPTION

WS5 RAINSCREEN FURRING OPTION

KEYNOTE B2015 EXTERIOR WALLS FINISH (WFE) STATUS

WFE1 FIBER CEMENT LAP SIDING BASELINE

WFE2 STEEL INSULATED SIDING OPTION

WFE3 STUCCO OPTION

WFE4 FIBER CEMENT PANEL SIDING OPTION

KEYNOTE B2017 EXTERIOR SOFFITS & FASCIA (EX) STATUS

EX1 FIBER CEMENT ENCLOSED SOFFITS & FASCIA BASELINE

EX2 STEEL INSULATED SIDING OPTION

EX3 STUCCO OPTION

KEYNOTE B2020 EXTERIOR WALL PROJECTIONS (WP) STATUS

WP1 CONCRETE PORCH BASELINE

WP2 DECKING, PRESSURE TREATED OPTION

WP3 DECKING, COMPOSITE WOOD OPTION

WP4 DECKING, REDWOOD OPTION

WP5 PREMANUFACTURED ALUMINUM GUARD RAIL BASELINE

WP6 PRESSURE TREAT WOOD RAILING OPTION

WP7 COMPOSITE METAL/WOOD RAILINGS OPTION

WP8 RODENT PROTECTION MESH OPTION

KEYNOTE B2030 EXTERIOR WINDOWS (WD) STATUS

WD1 VINYL, SLIDER, INSULATED DOUBLE GLAZED BASELINE

WD2 FIBERGLASS, SLIDER, INSULATED DOUBLE GLAZED OPTION

WD3 ALUMINUM WOOD CLAD, INSULATED DOUBLE GLAZED OPTION

KEYNOTE B2040 EXTERIOR DOORS (DE) STATUS

DE1 PRE-HUNG EXTERIOR DOOR, METAL CLAD, PRE-FINISHED BASELINE

DE2 HANDICAP OPENING DEVICES OPTION

DE3 HURRICANE STORM DOORS OPTION

DE4 SCREEN DOORS OPTION

B30 ROOFING

KEYNOTE B3010 ROOF COVERINGS (RC) STATUS

RC1 ARCHITECTURAL ASPHALT SYSTEM, 30 YEAR WARRANTY BASELINE

RC2 PREFORMED METAL ROOF PANELS OPTION

RC3 ICE WATER SHIELD OPTION

RC4 ARCHITECTURAL ASPHALT, LIFETIME WARRANTY OPTION

RC5 CEDAR SHAKE OPTION

RC6 WOOD SHINGLE ROOF OPTION

RC7 STANDING SEAM METAL ROOF OPTION

RC8 EPDM 40 MIL ROOFING OPTION

KEYNOTE B3020 ROOF ACCESSORIES (RA) STATUS

RA1 GUTTERS & DOWNSPOUTS, 5" ALUMINUM, 24 GAUGE BASELINE

RA2 5" GALVANIZED, 24 GAUGE OPTION

RA3 SOLAR TUBE OPTION

RA4 MECHANICAL ROOF ATTIC FAN OPTION

RA5

SCUPPER WITH INCORPORATED OVERFLOW DRAIN &

DOWNSPOUTS, 5" ALUMINUM, 24 GAUGE OPTION

C10 INTERIOR CONSTRUCTION

KEYNOTE C1010 INTERIOR PARTITIONS (WI) STATUS

WI1 2X WOOD STUDD FRAMED PARTITION BASELINE

WI2 5/8" GYPSUM BOARD BASELINE

WI3 1/2" GYPSUM BOARD OPTION

WI4 IMPACT RESISTANT DRYWALL OPTION

WI7 WALL INSULATION BASELINE

WI8 WATER RESISTANT 1/2" GYPSUM BOARD BASELINE

WI9 5/8" TYPE X GYPSUM BOARD BASELINE

KEYNOTE C1020 INTERIOR DOORS (DI) STATUS

DI1 PRE-HUNG, 6-PANEL, SOLID CORE BASELINE

DI2 PRE-HUNG, 6-PANEL, HOLLOW CORE OPTION

DI3 PRE-HUNG, FLUSH PANEL, SOLID CORE OPTION

DI4 PRE-HUNG, FLUSH PANEL, HOLLOW CORE OPTION

DI5 PRE-HUNG, LOUVERED DOOR OPTION

KEYNOTE C1021 INTERIOR HARDWARE (H) STATUS

HI1

INTERIOR HARDWARE PER ANSI/BHMA, GRADE 2 NOTE: MUST BE

COMPATIBLE WITH PARK STANDARD BASELINE

HI2 INTERIOR HARDWARE PER ANSI/BHMA, GRADE 1 OPTION

HI3 INTERIOR HARDWARE PER ANSI/BHMA, GRADE 3 BASELINE

HI4 INTERIOR HARDWARE PER ANSI/BHMA, GRADE 2 BASELINE

HI5 EXTERIOR HARDWARE PER ANSI/BHMA, GRADE 1 BASELINE

KEYNOTE C1030 FURNISHINGS (FN) STATUS

FN1 COUNTERTOPS AND BACKSPLASH, LAMINATED, BULLNOSE BASELINE

FN2

COUNTERTOPS AND BACKSPLASH, SOLID SURFACE (I.E. CORIAN,

QUARTZ, RECYCLED, ETC.) OPTION

FN3 CABINETS, LIGHT OAK RESIDENTIAL W/ STILE & RAIL PANEL DOORS BASELINE

FN4 ACCESSIBLE FURNITURE BY PARK

KEYNOTE C1040 FITTINGS (FT) STATUS

FT1 CLOSET SHELVING, PAINTED WOOD BASELINE

FT2 CLOSET SHELVING, WIRE OPTION

FT3 CLOSET SHELVING, LAMINATED OPTION

FT4 WINDOW SILLS, PAINTED WOOD BASELINE

FT5 WINDOW SILLS, SOLID SURFACE OPTION

FT6 TRIM, DOOR CASING, PAINTED WOOD BASELINE

KEYNOTE C1050 SPECIALTIES (SP) STATUS

SP1 IDENTIFYING DEVICES BASELINE

SP2 STORAGE SHELVING, PAINTED PARTICLE BOARD BASELINE

SP3 MIRRORS, WALL ADHERED, PLATE GLASS BASELINE

C30 INTERIOR FINISHES

KEYNOTE C3020 FLOOR FINISHES (FF) STATUS

FF1 COMMERCIAL CARPET BASELINE

FF2 RESILIENT SHEET GOODS FLOORING BASELINE

FF3 COMMERCIAL LAMINATE FLOORING OPTION

FF4 PORCELAIN TILE OPTION

FF5 RESILIENT WALL BASE BASELINE

FF6 WOOD WALL BASE OPTION

KEYNOTE C3010 WALL FINISHES (WF) STATUS

WF1 PAINTING BASELINE

WF2 LIGHT ORANGE PEEL BASELINE

WF3 KNOCK DOWN OPTION

WF4 PORCELAIN TILE BASELINE

KEYNOTE C3030 CEILING FINISHES (CF) STATUS

CF1 ORANGE PEEL BASELINE

CF2 KNOCK DOWN OR OTHER LOCAL FINISH OPTION

E10 EQUIPMENT

KEYNOTE E1015 KITCHEN APPLIANCES (KI) STATUS

KI1 REFRIGERATOR BY PARK

KI2 RANGE BY PARK

KI3 DISHWASHER BY PARK

KI4 RANGE HOOD BASELINE

KI5 BUILT-IN MICROWAVE BY PARK

KI6 WASHER BY PARK

KI7 DRYER BY PARK

KI8 GARBAGE DISPOSAL OPTION

E20 FURNISHINGS

KEYNOTE E2010 FIXED FURNISHINGS (FX) STATUS

FX1 MINIBLINDS BY PARK

FX2 SHADES BY PARK

FX3 OTHER BY PARK

F10 BUILDING DESIGN OPTIONS

KEYNOTE BUILDING DESIGN STATUS

BA1 GARAGE OPTION

BA2 PORCH COVER OPTION

BA3 PORCH DECK OPTION

BA4 GARAGE WITH ROLL-UP PRE-FINISHED PANELED STEEL DOOR OPTION

BA5 SLIDING GLASS PATIO DOOR OPTION

AutoCAD SHX Text

GENERAL ARCHITECTURAL AND STRUCTURAL KEYNOTES / BUILDING OPTION DESIGNATIONS

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

1. THE BASELINE DESIGN IS THE BASIS OF THE ACCEPTED THE BASELINE DESIGN IS THE BASIS OF THE ACCEPTED "WASO COST MODEL". IF OPTIONS AND SITE SPECIFIC REQUIREMENTS ARE USED THAT PUSH THE COST BEYOND THE ACCEPTED COST MODEL GUIDELINES, JUSTIFICATION WILL NEED TO BE PROVIDED/COORDINATED WITH WASO AND PARK FOR ADDITIONAL COSTS. 2. ARCHITECT TO REMOVE ALL UNUSED OPTIONS PLANS, ARCHITECT TO REMOVE ALL UNUSED OPTIONS PLANS, DETAILS, KEYNOTES AND REFERENCES WITHIN THE FINAL CONSTRUCTION DOCUMENTS.

AutoCAD SHX Text BASELINE: THE BASIS OF THE ACCEPTED "WASO COST MODEL" INCLUDES THE BASIS OF THE ACCEPTED "WASO COST MODEL" INCLUDES TYPICAL MATERIALS, COMPONENTS, STRUCTURE, AND MECHANICAL AND ELECTRICAL SYSTEMS AS INDICATED. OPTION OR BY PARK: ALTERNATE MATERIALS, COMPONENTS OR SYSTEMS ALTERNATE MATERIALS, COMPONENTS OR SYSTEMS TO BE SELECTED BY THE PARK FROM THE KEYNOTES/BUILDING OPTION DESIGNATIONS ON SHEETS G2 AND G3 OR FROM THE DESIGN OPTIONS NOTED BELOW. ALL OPTIONS TO BE FINALIZED PRIOR TO ISSUING CONSTRUCTION DOCUMENTS. A. CONSTRUCTION DOCUMENTS: A/E IS RESPONSIBLE FOR ADDITIONAL CONSTRUCTION DOCUMENTS: A/E IS RESPONSIBLE FOR ADDITIONAL A/E IS RESPONSIBLE FOR ADDITIONAL DRAWINGS, DETAILS AND NOTES REQUIRED FOR OPTIONS NOT SHOWN WITHIN THIS SET I.E. BASEMENT OPTION, STAIRS, FIRE PROTECTION, FIXTURES, HVAC, LIGHTING, ETC. B. FLAT ROOF OPTION FLAT ROOF OPTION PROVIDE LOW-SLOPED SINGLE MEMBRANE ROOF WITH PARAPET WALL OPTION DECIDED BY PARK. FLAT ROOF OPTION ELEVATIONS, SECTIONS, AND DETAILS ARE PROVIDED IN THIS SET. SHEETS FOR BASELINE SLOPED ROOF SHALL BE REMOVED FROM SET IF FLAT ROOF OPTION WILL BE USED. C. SLIDING PATIO DOOR OPTION SLIDING PATIO DOOR OPTION PARK TO DETERMINE IF A SLIDING PATIO DOOR AS NOTED ON FLOOR PLAN IS APPLICABLE BASED ON RENTAL RATES FOR "APARTMENT" OR "UNIT" DESIGNATION. RATES TO BE VERIFIED WITH REGIONAL HOUSING MANAGER. SLIDING DOOR OPTION TO INCLUDE CONCRETE PAD OR DECK PER EXTERIOR WALL PROJECTION OPTIONS SHEET G2. COORDINATION WITH MEP REQUIRED FOR VTAC LOCATIONS. D. ENTRY PORCH ROOF OPTION ENTRY PORCH ROOF OPTION PARK TO DETERMINE IF A ENTRY PORCH ROOF AS NOTED ON THE EXTERIOR ELEVATIONS IS NEEDED. E. GARAGE OPTION GARAGE OPTION TWO CAR DETACHED GARAGES MAY BE ADDED TO THE SCOPE OF THE PROJECT IF PARK DETERMINES TO BE NECESSARY. F. LAUNDRY AND STORAGE LAUNDRY AND STORAGE A COMMON LAUNDRY ROOM SPACE AND STORAGE CAN BE ADDED TO THE DETACHED GARAGE BUILDING, IT COULD REPLACE A GARAGE BAY OR CAN BE ADDED TO THE BUILDING AS NEED IT OR REQUIRED BY THE PARK. IF THIS OPTION IS SELECTED, HEATING AND OTHER UTILITIES HAVE TO BE ADDED. G. BASEMENT OPTION BASEMENT OPTION BASEMENT FOUNDATION TO BE DETERMINED FOR SPECIFIC SITE CONDITIONS AND DETERMINED BY PARK. H. CRAWLSPACE OPTION CRAWLSPACE OPTION FOUNDATION WALLS WITH CRAWLSPACE TO BE USED WHERE APPROPRIATE FOR SPECIFIC SITE CONDITIONS AND AS DETERMINED BY STRUCTURAL ENGINEER. I. STORAGE UNITS STORAGE UNITS A DETACHED STORAGE BUILDING WITH TWO BAYS MAY BE ADDED AS DRAWN TO THE SCOPE OF THE PROJECT IF PARK DETERMINES TO BE REQUIRED OR NECESSARY. J. INCORPORATED STORAGE UNITS INCORPORATED STORAGE UNITS A INCORPORATED MODULAR STORAGE UNIT MAY BE ADDED TO THE TO THE SCOPE OF THE PROJECT IF PARK DETERMINES TO BE REQUIRED OR NECESSARY. AS DRAWN, THIS UNIT COULD BE LOCATED IN BE LOCATED IN THE MIDDLE OF EACH SINGLE STORY PLAN TYPE AND TWO TYPE AND TWO ON TOP OF EACH OTHER IN THE TWO STORY BUILDINGS.

AutoCAD SHX Text

GENERAL NOTES FOR DESIGN OPTIONS

AutoCAD SHX Text

AutoCAD SHX Text 149091

AutoCAD SHX Text

BUILDING 9 SINGLE FAMILY HOUSE

AutoCAD SHX Text

NPS HOUSING PROTOTYPE DESIGN CATALOG

AutoCAD SHX Text N/A

AutoCAD SHX Text G2

AutoCAD SHX Text

GENERAL KEYNOTES - ARCHITECTURAL & STRUCTURAL

AutoCAD SHX Text Plotted: 11/4/2020 1:27 PM File Location: y:\Shared\Projects\national park service\33040-housing waso\40.0-cadd\WASO\DRAWINGS\building 9\GEN\G2 GENERAL KEYNOTES - ARCHITECTURAL & STRUCTURAL.dwg 11/4/2020 1:27 PM File Location: y:\Shared\Projects\national park service\33040-housing waso\40.0-cadd\WASO\DRAWINGS\building 9\GEN\G2 GENERAL KEYNOTES - ARCHITECTURAL & STRUCTURAL.dwg File Location: y:\Shared\Projects\national park service\33040-housing waso\40.0-cadd\WASO\DRAWINGS\building 9\GEN\G2 GENERAL KEYNOTES - ARCHITECTURAL & STRUCTURAL.dwg y:\Shared\Projects\national park service\33040-housing waso\40.0-cadd\WASO\DRAWINGS\building 9\GEN\G2 GENERAL KEYNOTES - ARCHITECTURAL & STRUCTURAL.dwg

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text

TECH. REVIEW:

AutoCAD SHX Text

SUB SHEET NO.

AutoCAD SHX Text

PMIS/PKG NO.

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

TITLE OF SHEET

AutoCAD SHX Text

EF

AutoCAD SHX Text

EF, JP, ML

AutoCAD SHX Text

MN, KJ, MP

AutoCAD SHX Text 10/20

AutoCAD SHX Text

AutoCAD SHX Text

E2010 CONVEYING STATUS

CY1 HYDRAULIC N/A

CY2 TRACTION WITH MACHINE ROOM N/A

CY3 LIFTS N/A

D2005 MONITORING STATUS

PB1 METERING, WATER BASELINE

PB2 METERING, NATURAL GAS BASELINE

D2010 PLUMBING FIXTURES, RESIDENTIAL GRADE STATUS

PF1 TOILETS BASELINE

PF2 VANITIES BASELINE

PF3 SHOWERS BASELINE

PF4 BATHTUBS OPTION

PF5 HOSE BIBS BASELINE

PF6 SINKS BASELINE

PF7 KITCHEN FAUCETS BASELINE

PF8 SHOWER PAN BASELINE

PF9 SHOWER FIBERGLASS WALL 3-PIECE SURROUND BASELINE

D2020 DOMESTIC WATER DISTRIBUTION STATUS

DWD1 HOT/COLD WATER PLASTIC PIPING, PEX BASELINE

DWD2 HOT/COLD WATER PIPING, COPPER OPTION

D2025 DOMESTIC WATER HEATER STATUS

WH1 HOT WATER HEATER 80% BASELINE

EWH1 ELECTRIC HOT WATER HEATER 90% OPTION

TWH1 TANKLESS ELECTRIC WATER HEATER OPTION

D2030 SANITARY WASTE & VENT STATUS

SW1 BELOW GRADE, PVC, SCHEDULE 80 BASELINE

SW2 ABOVE GRADE, PVC, SCHEDULE 40 BASELINE

D2040 RAIN WATER DRAINAGE (FLAT ROOF) STATUS

RW1 SCUPPERS AND DOWNSPOUTS BASELINE

RW2 INTERNAL PIPE DRAINAGE SYSTEM OPTION

D2090 NATURAL GAS PLUMBING SYSTEMS STATUS

NG1 FLEXIBLE TUBING, STAINLESS STEEL BASELINE

NG2 STEEL PIPING ABOVE GROUND LPG OR NATURAL GAS OPTION

NG3 POLYETHYLENE PIPING BELOW GROUND LPG OR NATURAL BASELINE

D10 CONVEYING SYSTEMS

D20 PLUMBING

D3010 ENERGY SUPPLY (ES) STATUS

ES1 LOCAL UTILITY AGENCY BASELINE

D3020 HEAT GENERATING SYSTEMS (HS)

STATUS

HS1 80% FURNACES BASELINE

HS2 90% FURNACES OPTION

HS4 AIR SOURCE HEAT PUMPS (HEATING & COOLING) OPTION

HS5 PTAC - PACKAGE TERMINAL AIR CONDITIONERS HEAT & COOL OPTION

D3030 COOLING GENERATING SYSTEMS (CS)

STATUS

CS1 EVAPORATIVE COOLER OPTION

CS2 REFRIGERATED WITH CONDENSER AND FURNACE OPTION

CS3 WHOLE HOUSE FAN OPTION

D3040 DISTRIBUTION SYSTEMS (DS) STATUS

DS1 DUCTWORK, GALVANIZED BASELINE

DS2 DUCTWORK, FLEX DUCT OPTION

DS3 HYDRONICS OPTION

D3060 CONTROLS & INSTRUMENTATION STATUS

IC1 MANUAL BASELINE

IC2 PROGRAMMABLE THERMOSTAT OPTION

IC3 PROGRAMMABLE ENERGY MANAGEMENT SYSTEM OPTION

D3090 OTHER HVAC SYSTEMS & EQUIPMENT STATUS

H1 HUMIDITY CONTROL OPTION

D30 HVAC

D1010 SPRINKLER NFPA 13R MULTI-FAMILY OR NFPA 13D

SINGLE/DUPLEX

STATUS

FP1 PLASTIC PIPE, CPVC, SCHEDULE 40 BASELINE

FP2 COPPER PIPE OPTION

FP3 BLACK STEEL, SCHEDULE 40 OPTION

FP4 DRY ASSEMBLY SITE SPECIFIC

FP5 FLEXIBLE SPRINKLER HOSE CONNECTIONS OPTION

FP6 DEDICATED FIRE SERVICE MAIN SITE SPECIFIC

FP7 BACKFLOW PREVENTER SITE SPECIFIC

D4090 OTHER FIRE PROTECTION SYSTEMS STATUS

FPS1 CARBON MONOXIDE SYSTEMS BASELINE

FPS2 SMOKE DETECTION SYSTEMS BASELINE

FPS3 FIRE EXTINGUISHERS AND CABINETS BASELINE

RADON DETECTION SYSTEM OPTION

D5010 ELECTRICAL SERVICE DISTRIBUTION STATUS

DS1 METERING BASELINE

DS2 ALL ELECTRIC NO GAS SITE SPECIFIC

D5020 LIGHTING AND BRANCH WIRING DISTRIBUTION STATUS

PS3 ROMEX INTERIOR WIRING BASELINE

PS4 EMT CONDUIT OR MC CABLE - ATTIC & CRAWL SPACE OPTION

PS1 OUTDOOR ELECTRICAL OUTLETS GFI PROTECTED BASELINE

PS2 DISHWASHER OPTION

PS5 PENINSULA KITCHEN OUTLETS OPTION

D5020 LIGHTING FIXTURES STATUS

LS1 INDOOR LED BASELINE

LS2 EXTERIOR LIGHTING LED BASELINE

LS3 PHOTOCELL OPTION

INDOOR INCANDESCENT, FLUORESCENT, & HALOGEN OPTION

D5030 COMMUNICATIONS AND SECURITY STATUS

CM1 TELEPHONE LAND LINE BASELINE

CM2 TECHNOLOGY READY BUILDING OPTION

CM3 CELL PHONE SERVICE OPTION

CM4 TELEVISION OPTION

CM5 INTERNET OPTION

CM6 FIRE DETECTION SYSTEM OPTION

CM7 SECURITY BASELINE

D5090 OTHER ELECTRICAL SYSTEMS STATUS

ES1 EMERGENCY GENERATOR LIGHT/POWER OPTION

ES2 GENERATOR PANEL HOOKUP OPTION

D40 FIRE PROTECTION (GIVE GUIDANCE TO PARKS)

D50 ELECTRICAL

AutoCAD SHX Text BASELINE: THE BASIS OF THE ACCEPTED "WASO COST MODEL" INCLUDES THE BASIS OF THE ACCEPTED "WASO COST MODEL" INCLUDES TYPICAL MATERIALS, COMPONENTS, STRUCTURE, AND MECHANICAL AND ELECTRICAL SYSTEMS AS INDICATED. OPTION OR BY PARK: ALTERNATE MATERIALS, COMPONENTS OR SYSTEMS ALTERNATE MATERIALS, COMPONENTS OR SYSTEMS TO BE SELECTED BY THE PARK FROM THE KEYNOTES/BUILDING OPTION DESIGNATIONS ON SHEETS G2 AND G3 OR FROM THE DESIGN OPTIONS NOTED BELOW. ALL OPTIONS TO BE FINALIZED PRIOR TO ISSUING CONSTRUCTION DOCUMENTS. A. CONSTRUCTION DOCUMENTS: A/E IS RESPONSIBLE FOR ADDITIONAL CONSTRUCTION DOCUMENTS: A/E IS RESPONSIBLE FOR ADDITIONAL A/E IS RESPONSIBLE FOR ADDITIONAL DRAWINGS, DETAILS AND NOTES REQUIRED FOR OPTIONS NOT SHOWN WITHIN THIS SET I.E. BASEMENT OPTION, STAIRS, FIRE PROTECTION, FIXTURES, HVAC, LIGHTING, ETC. B. FLAT ROOF OPTION FLAT ROOF OPTION PROVIDE LOW-SLOPED SINGLE MEMBRANE ROOF WITH PARAPET WALL OPTION DECIDED BY PARK. FLAT ROOF OPTION ELEVATIONS, SECTIONS, AND DETAILS ARE PROVIDED IN THIS SET. SHEETS FOR BASELINE SLOPED ROOF SHALL BE REMOVED FROM SET IF FLAT ROOF OPTION WILL BE USED. C. SLIDING PATIO DOOR OPTION SLIDING PATIO DOOR OPTION PARK TO DETERMINE IF A SLIDING PATIO DOOR AS NOTED ON FLOOR PLAN IS APPLICABLE BASED ON RENTAL RATES FOR "APARTMENT" OR "UNIT" DESIGNATION. RATES TO BE VERIFIED WITH REGIONAL HOUSING MANAGER. SLIDING DOOR OPTION TO INCLUDE CONCRETE PAD OR DECK PER EXTERIOR WALL PROJECTION OPTIONS SHEET G2. COORDINATION WITH MEP REQUIRED FOR VTAC LOCATIONS. D. ENTRY PORCH ROOF OPTION ENTRY PORCH ROOF OPTION PARK TO DETERMINE IF A ENTRY PORCH ROOF AS NOTED ON THE EXTERIOR ELEVATIONS IS NEEDED. E. GARAGE OPTION GARAGE OPTION TWO CAR DETACHED GARAGES MAY BE ADDED TO THE SCOPE OF THE PROJECT IF PARK DETERMINES TO BE NECESSARY. F. LAUNDRY AND STORAGE LAUNDRY AND STORAGE A COMMON LAUNDRY ROOM SPACE AND STORAGE CAN BE ADDED TO THE DETACHED GARAGE BUILDING, IT COULD REPLACE A GARAGE BAY OR CAN BE ADDED TO THE BUILDING AS NEED IT OR REQUIRED BY THE PARK. IF THIS OPTION IS SELECTED, HEATING AND OTHER UTILITIES HAVE TO BE ADDED. G. BASEMENT OPTION BASEMENT OPTION BASEMENT FOUNDATION TO BE DETERMINED FOR SPECIFIC SITE CONDITIONS AND DETERMINED BY PARK. H. CRAWLSPACE OPTION CRAWLSPACE OPTION FOUNDATION WALLS WITH CRAWLSPACE TO BE USED WHERE APPROPRIATE FOR SPECIFIC SITE CONDITIONS AND AS DETERMINED BY STRUCTURAL ENGINEER. I. STORAGE UNITS STORAGE UNITS A DETACHED STORAGE BUILDING WITH TWO BAYS MAY BE ADDED AS DRAWN TO THE SCOPE OF THE PROJECT IF PARK DETERMINES TO BE REQUIRED OR NECESSARY. J. INCORPORATED STORAGE UNITS INCORPORATED STORAGE UNITS A INCORPORATED MODULAR STORAGE UNIT MAY BE ADDED TO THE TO THE SCOPE OF THE PROJECT IF PARK DETERMINES TO BE REQUIRED OR NECESSARY. AS DRAWN, THIS UNIT COULD BE LOCATED IN BE LOCATED IN THE MIDDLE OF EACH SINGLE STORY PLAN TYPE AND TWO TYPE AND TWO ON TOP OF EACH OTHER IN THE TWO STORY BUILDINGS.

AutoCAD SHX Text

GENERAL NOTES FOR DESIGN OPTIONS

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

1. THE BASELINE DESIGN IS THE BASIS OF THE ACCEPTED THE BASELINE DESIGN IS THE BASIS OF THE ACCEPTED "WASO COST MODEL". IF OPTIONS AND SITE SPECIFIC REQUIREMENTS ARE USED THAT PUSH THE COST BEYOND THE ACCEPTED COST MODEL GUIDELINES, JUSTIFICATION WILL NEED TO BE PROVIDED/COORDINATED WITH WASO AND PARK FOR ADDITIONAL COSTS. 2. ARCHITECT TO REMOVE ALL UNUSED OPTIONS PLANS, ARCHITECT TO REMOVE ALL UNUSED OPTIONS PLANS, DETAILS, KEYNOTES AND REFERENCES WITHIN THE FINAL CONSTRUCTION DOCUMENTS.

AutoCAD SHX Text

GENERAL MEP KEYNOTES

AutoCAD SHX Text

%%USHEET KEYNOTES

AutoCAD SHX Text 1 FOR UNITS WITH THE LOCK OFF OPTION PROVIDE A FOR UNITS WITH THE LOCK OFF OPTION PROVIDE A SEPARATE METER AND LOAD CENTER BRANCH PANEL TO SERVE THAT SPACE. ALL EQUIPMENT WITHIN THE LOCK OFF SPACE TO BE CIRCUITED TO THIS PANEL. 2 FOR UNITS WITH THE LOCK OFF OPTION, HVAC SYSTEM FOR UNITS WITH THE LOCK OFF OPTION, HVAC SYSTEM WILL NEED TO BE PTAC IN ORDER TO MAINTAIN LOCAL TEMPERATURE CONTROL IN THIS SPACE.

AutoCAD SHX Text BASELINE: THE BASIS OF THE ACCEPTED "WASO COST MODEL" INCLUDES THE BASIS OF THE ACCEPTED "WASO COST MODEL" INCLUDES TYPICAL MATERIALS, COMPONENTS, STRUCTURE, AND MECHANICAL AND ELECTRICAL SYSTEMS AS INDICATED. OPTION OR BY PARK: ALTERNATE MATERIALS, COMPONENTS OR SYSTEMS ALTERNATE MATERIALS, COMPONENTS OR SYSTEMS TO BE SELECTED BY THE PARK FROM THE KEYNOTES/BUILDING OPTION DESIGNATIONS ON SHEETS G2 AND G3 OR FROM THE DESIGN OPTIONS NOTED BELOW. ALL OPTIONS TO BE FINALIZED PRIOR TO ISSUING CONSTRUCTION DOCUMENTS. A. CONSTRUCTION DOCUMENTS: A/E IS RESPONSIBLE FOR ADDITIONAL CONSTRUCTION DOCUMENTS: A/E IS RESPONSIBLE FOR ADDITIONAL A/E IS RESPONSIBLE FOR ADDITIONAL DRAWINGS, DETAILS AND NOTES REQUIRED FOR OPTIONS NOT SHOWN WITHIN THIS SET I.E. BASEMENT OPTION, STAIRS, FIRE PROTECTION, FIXTURES, HVAC, LIGHTING, ETC. B. FLAT ROOF OPTION FLAT ROOF OPTION PROVIDE LOW-SLOPED SINGLE MEMBRANE ROOF WITH PARAPET WALL OPTION DECIDED BY PARK. FLAT ROOF OPTION ELEVATIONS, SECTIONS, AND DETAILS ARE PROVIDED IN THIS SET. SHEETS FOR BASELINE SLOPED ROOF SHALL BE REMOVED FROM SET IF FLAT ROOF OPTION WILL BE USED. C. SLIDING PATIO DOOR OPTION SLIDING PATIO DOOR OPTION PARK TO DETERMINE IF A SLIDING PATIO DOOR AS NOTED ON FLOOR PLAN IS APPLICABLE BASED ON RENTAL RATES FOR "APARTMENT" OR "UNIT" DESIGNATION. RATES TO BE VERIFIED WITH REGIONAL HOUSING MANAGER. SLIDING DOOR OPTION TO INCLUDE CONCRETE PAD OR DECK PER EXTERIOR WALL PROJECTION OPTIONS SHEET G2. COORDINATION WITH MEP REQUIRED FOR VTAC LOCATIONS. D. ENTRY PORCH ROOF OPTION ENTRY PORCH ROOF OPTION PARK TO DETERMINE IF A ENTRY PORCH ROOF AS NOTED ON THE EXTERIOR ELEVATIONS IS NEEDED. E. GARAGE OPTION GARAGE OPTION TWO CAR DETACHED GARAGES MAY BE ADDED TO THE SCOPE OF THE PROJECT IF PARK DETERMINES TO BE NECESSARY. F. LAUNDRY AND STORAGE LAUNDRY AND STORAGE A COMMON LAUNDRY ROOM SPACE AND STORAGE CAN BE ADDED TO THE DETACHED GARAGE BUILDING, IT COULD REPLACE A GARAGE BAY OR CAN BE ADDED TO THE BUILDING AS NEED IT OR REQUIRED BY THE PARK. IF THIS OPTION IS SELECTED, HEATING AND OTHER UTILITIES HAVE TO BE ADDED. G. BASEMENT OPTION BASEMENT OPTION BASEMENT FOUNDATION TO BE DETERMINED FOR SPECIFIC SITE CONDITIONS AND DETERMINED BY PARK. H. CRAWLSPACE OPTION CRAWLSPACE OPTION FOUNDATION WALLS WITH CRAWLSPACE TO BE USED WHERE APPROPRIATE FOR SPECIFIC SITE CONDITIONS AND AS DETERMINED BY STRUCTURAL ENGINEER. I. STORAGE UNITS STORAGE UNITS A DETACHED STORAGE BUILDING WITH TWO BAYS MAY BE ADDED AS DRAWN TO THE SCOPE OF THE PROJECT IF PARK DETERMINES TO BE REQUIRED OR NECESSARY. J. INCORPORATED STORAGE UNITS INCORPORATED STORAGE UNITS A INCORPORATED MODULAR STORAGE UNIT MAY BE ADDED TO THE TO THE SCOPE OF THE PROJECT IF PARK DETERMINES TO BE REQUIRED OR NECESSARY. AS DRAWN, THIS UNIT COULD BE LOCATED IN BE LOCATED IN THE MIDDLE OF EACH SINGLE STORY PLAN TYPE AND TWO TYPE AND TWO ON TOP OF EACH OTHER IN THE TWO STORY BUILDINGS.

AutoCAD SHX Text

GENERAL NOTES FOR DESIGN OPTIONS

AutoCAD SHX Text

AutoCAD SHX Text 149091

AutoCAD SHX Text

BUILDING 9 SINGLE FAMILY HOUSE

AutoCAD SHX Text

NPS HOUSING PROTOTYPE DESIGN CATALOG

AutoCAD SHX Text N/A

AutoCAD SHX Text G3

AutoCAD SHX Text

GENERAL KEYNOTES - MEP

AutoCAD SHX Text Plotted: 11/4/2020 1:27 PM File Location: y:\Shared\Projects\national park service\33040-housing waso\40.0-cadd\WASO\DRAWINGS\building 9\GEN\G3 GENERAL KEYNOTES - MEP.dwg 11/4/2020 1:27 PM File Location: y:\Shared\Projects\national park service\33040-housing waso\40.0-cadd\WASO\DRAWINGS\building 9\GEN\G3 GENERAL KEYNOTES - MEP.dwg File Location: y:\Shared\Projects\national park service\33040-housing waso\40.0-cadd\WASO\DRAWINGS\building 9\GEN\G3 GENERAL KEYNOTES - MEP.dwg y:\Shared\Projects\national park service\33040-housing waso\40.0-cadd\WASO\DRAWINGS\building 9\GEN\G3 GENERAL KEYNOTES - MEP.dwg

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text

TECH. REVIEW:

AutoCAD SHX Text

SUB SHEET NO.

AutoCAD SHX Text

PMIS/PKG NO.

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

TITLE OF SHEET

AutoCAD SHX Text

EF

AutoCAD SHX Text

EF, JP, ML

AutoCAD SHX Text

MN, KJ, MP

AutoCAD SHX Text 10/20

AutoCAD SHX Text

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

1. LOCATE THERMAL INSULATION ON THE LOCATE THERMAL INSULATION ON THE COLD SIDE (IN WINTER) OF DOMESTIC WATER PIPES AS REQUIRED TO PROTECT PIPES FROM FREEZING. 2. PROVIDE ADDITIONAL FRAMING, PROVIDE ADDITIONAL FRAMING, BLOCKING, AND FINISHES AS REQUIRED FOR ACCESS PANELS AND DOORS. 3. PROVIDE ADDITIONAL BLOCKING OR PROVIDE ADDITIONAL BLOCKING OR INSERTS AS REQUIRED TO SUPPORT SHELVING, TOWEL BARS, RAILINGS, AND ALL OTHER WALL-MOUNTED ACCESSORIES AND EQUIPMENT. 4. WALLS RATED FOR FIRE AND/OR WALLS RATED FOR FIRE AND/OR SOUND MUST BE CONSTRUCTED AS DOCUMENTED TO ACHIEVE TESTED VALUE.

AutoCAD SHX Text

BASELINE - 3 1/2" SOUND BATT INSULATION IN STUD CAVITY

AutoCAD SHX Text

2X4 WOOD STUDS 16" OC, SEE STRUCTURAL

AutoCAD SHX Text NOTE: ADD SHEAR WALL SHEATHING OVER ADD SHEAR WALL SHEATHING OVER STUDS AS REQUIRED BY STRUCTURAL

AutoCAD SHX Text

SOUND BATT INSULATION AT 4A & 4B ONLY

AutoCAD SHX Text

AutoCAD SHX Text

BASELINE - NON-RATED INTERIOR WALL (NON-INSULATED)

AutoCAD SHX Text

AutoCAD SHX Text

BASELINE - SLAB ON GRADE

AutoCAD SHX Text

4" CONCRETE SLAB ON GRADE WITH WELDED WIRE MESH, SEE STRUCTURAL

AutoCAD SHX Text

10 MIL VAPOR BARRIER

AutoCAD SHX Text

DRAINAGE COURSE, THICKNESS BY SPECIFIC PARK CONDITIONS

AutoCAD SHX Text

FILL SOIL LAYER

AutoCAD SHX Text OPTION - PROVIDE 2' OF 2-INCH WIDE RIGID INSULATION AT PERIMETER. R-VALUE PER SITE SPECIFIC CONDITIONS.

AutoCAD SHX Text

ASSEMBLY: GA WP 3370 (OR EQUAL) FIRE: 1-HR, STC: 52

AutoCAD SHX Text

UNIT

AutoCAD SHX Text

2 X 4 WOOD STUDS, 16" OC MAX, SEE STRUCTURAL

AutoCAD SHX Text 3 1/2" UNFACED FIBERGLASS BATT INSULATION, R-11 (R-VALUE MIGHT CHANGE PER SITE CONDITIONS)

AutoCAD SHX Text

1" MIN AIR SPACE BETWEEN WALLS. FIRE BLOCK @ 10'-0" OC HORIZONTAL AND VERTICAL

AutoCAD SHX Text

DEMISING LINE

AutoCAD SHX Text

UNIT

AutoCAD SHX Text

5/8" TYPE 'X' GYPSUM BOARD EA. SIDE

AutoCAD SHX Text

SHEARWALL SHEATHING WHERE REQUIRED BY STRUCTURAL

AutoCAD SHX Text

AutoCAD SHX Text

BASELINE - 1HR INTERIOR FIRE RATED DEMISING WALL

AutoCAD SHX Text

WE1A

AutoCAD SHX Text S1

AutoCAD SHX Text

WI1

AutoCAD SHX Text

INTERIOR

AutoCAD SHX Text

EXTERIOR

AutoCAD SHX Text

WEATHER RESISTANT BARRIER (WRB)

AutoCAD SHX Text

R-21 FIBERGLASS BATT INSULATION

AutoCAD SHX Text 2 x 6 WOOD STUDS, 16" OC, SEE STRUCTURAL

AutoCAD SHX Text

PREMANUFACTURED WOOD TRUSSES, SEE STRUCTURAL

AutoCAD SHX Text

30 LB ROOFING FELT

AutoCAD SHX Text

WOOD ROOF SHEATHING, SEE STRUCTURAL

AutoCAD SHX Text INSULATION IS PER FEDERAL NPS REQUIREMENTS UNLESS THE LOCAL/STATE REQUIREMENT IS STRICTER

AutoCAD SHX Text

WI3

AutoCAD SHX Text

FIBER CEMENT LAP SIDING (SEE G2 FOR SIDING MATERIAL OPTIONS)

AutoCAD SHX Text

WFE1

AutoCAD SHX Text

AutoCAD SHX Text

WS3

AutoCAD SHX Text

WE1A

AutoCAD SHX Text

WS4

AutoCAD SHX Text

WS1

AutoCAD SHX Text

WS2

AutoCAD SHX Text

1/2" OSB SHEATHING OR 5/8" PLYWOOD, SEE STRUCT.

AutoCAD SHX Text

ARCHITECTURAL ASPHALT (SEE G2 FOR OPTIONAL ROOF COVERINGS)

AutoCAD SHX Text

RC1

AutoCAD SHX Text

AutoCAD SHX Text

BASELINE - NON-RATED SLOPED ROOF/CEILING

AutoCAD SHX Text

RF2

AutoCAD SHX Text

RF1

AutoCAD SHX Text

5/8" OSB SUBFLOOR, SEE STRUCTURAL

AutoCAD SHX Text

TJI CLOSE WEB OR TJI OPEN WEB, SEE STRUCTURAL

AutoCAD SHX Text

INSULATION (PER LOCAL ENERGY CODE)

AutoCAD SHX Text

AutoCAD SHX Text

BASELINE - 1-HR RATED FLOOR/CEILING

AutoCAD SHX Text

FC1

AutoCAD SHX Text

FC2

AutoCAD SHX Text

WI2

AutoCAD SHX Text

WI3

AutoCAD SHX Text

5/8" GYPSUM BOARD OR 1/2" GYPSUM BOARD

AutoCAD SHX Text

EPDM MEMBRANE

AutoCAD SHX Text

AutoCAD SHX Text

6" MIN POLYISOCYANURATE RIGID INSULATION - SEE ROOF PLAN

AutoCAD SHX Text

WOOD ROOF SHEATHING, SEE STRUCTURAL

AutoCAD SHX Text

TJL OPEN WEB

AutoCAD SHX Text 4A

AutoCAD SHX Text

BASELINE - 5 1/2" SOUND BATT INSULATION IN STUD CAVITY

AutoCAD SHX Text

2X6 WOOD STUDS 16" OC, SEE STRUCTURAL

AutoCAD SHX Text NOTE: ADD SHEAR WALL SHEATHING OVER ADD SHEAR WALL SHEATHING OVER STUDS AS REQUIRED BY STRUCTURAL

AutoCAD SHX Text

SOUND BATT INSULATION AT 8A & 8B ONLY

AutoCAD SHX Text

AutoCAD SHX Text

BASELINE - NON-RATED INTERIOR WALL

AutoCAD SHX Text

WI1

AutoCAD SHX Text

WI2

AutoCAD SHX Text

WI3

AutoCAD SHX Text

5/8" GYPSUM BOARD OR 1/2" GYPSUM BOARD

AutoCAD SHX Text 8A

AutoCAD SHX Text

2X4 WOOD STUDS 16" O.C., SEE STRUCTURAL

AutoCAD SHX Text NOTE: ADD SHEAR WALL SHEATHING ADD SHEAR WALL SHEATHING OVER STUDS AS REQ'D BY STRUCTURAL

AutoCAD SHX Text

AutoCAD SHX Text

BASELINE - NON-RATED INTERIOR WALL AT SHOWER SHAFT

AutoCAD SHX Text

WI1

AutoCAD SHX Text

1/2" CEMENT BACKER BOARD

AutoCAD SHX Text 11A

AutoCAD SHX Text

ICE WATER SHIELD

AutoCAD SHX Text

RC3

AutoCAD SHX Text

RC8

AutoCAD SHX Text

RF2

AutoCAD SHX Text

1/4" PLYWOOD PROTECTION BOARD

AutoCAD SHX Text

RF3

AutoCAD SHX Text

WI9

AutoCAD SHX Text

WI7

AutoCAD SHX Text

1/2" PLYWOOD SHEATHING, AS REQUIRED BY STRUCTURAL

AutoCAD SHX Text

WI7

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

SEE SHEETS G2 & G3 FOR G2 & G3 FOR & G3 FOR G3 FOR FOR KEYNOTES

AutoCAD SHX Text

AutoCAD SHX Text

30LB ROOFING FELT

AutoCAD SHX Text BASELINE - PROVIDE WATER RESISTANT GYPSUM WALLBOARD AT WET WALL LOCATIONS, PROVIDE TILE AND BACKER BOARD AT SHOWER.

This is the start of the file's text. The full file is on GovTribe.