Questions_Round_5.pdf
PDF 221 KB Posted
- Attached to
- Electronics Cooling Water (ECW-50) Federal contract opportunity
- Solicitation number
- N68335-19-R-0202
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Questions_round_4.pdf | ||
| Questions_round_3.pdf | ||
| Questions_round_2.pdf | ||
| Questions_and_answers_WE_9.14.19.pdf | ||
| ATT_4_Data_Item_Transmittal_Acceptance_Rejection_Form_.doc | DOC document | |
| ATT_2_P1_Pricing_Spreadsheet_SSP.xlsx | XLSX spreadsheet | |
| N68335-19-R-0202_1.docx | DOCX document | |
| Exhibit_A_ECW-50_CDRLs__05.15.19.pdf | ||
| Att_1_ECW-50_Specifications.docx | DOCX document | |
| Att_3_Cross_Reference_Matrix_Template.docx | DOCX document | |
| Att_1_ECW-50_Specifications.docx | DOCX document | |
| N68335-19-R-0202.docx | DOCX document | |
| ATT_4_Data_Item_Transmittal_Acceptance_Rejection_Form_.doc | DOC document | |
| Att_3_Cross_Reference_Matrix_Template.docx | DOCX document | |
| Exhibit_A_ECW-50_CDRLs__05.15.19.pdf | ||
| ATT_2_P1_Pricing_Spreadsheet_SSP.xlsx | XLSX spreadsheet |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Questions Round 5 Solicitation: N68335-19-R-0202
Questions and answers:
Question 1: Please provide the ship’s chilled water temperature and flow rate that will be supplied to the ECW-50. Prior answers to this same question pointed to another document, DOD-STD-1399-532, as a guideline for the ship’s chilled water. The newest revision of this document, dated February 1990, does not specify a temperature or range of temperatures. The previous revision of this document, dated May 1978, states in section 5.2.2 that “the temperature of the cooling water provided to the electronic equipment inlet connections will not be greater than 40°C (105°F) on surface ships”. With 105°F chilled water, a liquid-to-liquid chiller will not allow the ECW supply to be in the range of 41°F and 59°F. We suspect that the ship’s chilled water is actually much lower than 105°F, but we’ll need to know what it is as it will directly affect the chillers heat exchanger size and chiller configuration. If the water is in fact 105°F, a liquid-to-refrigerant-to-liquid chiller configuration may be considered, which will use a vapor cycle to reject heat to the ships chilled water.
Response: In addition to the Government’s response dated 10/12/2019 Round 4 Questions, the CHW design temp is 45-50 deg F.