Questions_round_4.pdf

PDF 235 KB Posted

Attached to
Electronics Cooling Water (ECW-50) Federal contract opportunity
Solicitation number
N68335-19-R-0202
Issued by
Department of the Navy Naval Air Systems Command Naval Air Warfare Center

About this file

Questions and answers round 4.

View the file

Other files for this federal contract opportunity

Other files attached to Electronics Cooling Water (ECW-50), newest first.
File Type Posted
Questions_Round_5.pdf PDF
Questions_round_3.pdf PDF
Questions_round_2.pdf PDF
Questions_and_answers_WE_9.14.19.pdf PDF
Att_1_ECW-50_Specifications.docx DOCX document
Att_3_Cross_Reference_Matrix_Template.docx DOCX document
ATT_2_P1_Pricing_Spreadsheet_SSP.xlsx XLSX spreadsheet
N68335-19-R-0202_1.docx DOCX document
Exhibit_A_ECW-50_CDRLs__05.15.19.pdf PDF
ATT_4_Data_Item_Transmittal_Acceptance_Rejection_Form_.doc DOC document
Att_3_Cross_Reference_Matrix_Template.docx DOCX document
Exhibit_A_ECW-50_CDRLs__05.15.19.pdf PDF
ATT_2_P1_Pricing_Spreadsheet_SSP.xlsx XLSX spreadsheet
Att_1_ECW-50_Specifications.docx DOCX document
N68335-19-R-0202.docx DOCX document
ATT_4_Data_Item_Transmittal_Acceptance_Rejection_Form_.doc DOC document
Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Questions round 4, Week Ending 12 October 2019 Solicitation: N68335-19-R-0202

Questions and answers:

Question 1: Please provide the ship’s chilled water temperature and flow rate that will be supplied to the ECW-50. Prior answers to this same question pointed to another document, DOD-STD-1399-532, as a guideline for the ship’s chilled water. The newest revision of this document, dated February 1990, does not specify a temperature or range of temperatures. The previous revision of this document, dated May 1978, states in section 5.2.2 that “the temperature of the cooling water provided to the electronic equipment inlet connections will not be greater than 40°C (105°F) on surface ships”. With 105°F chilled water, a liquid-to-liquid chiller will not allow the ECW supply to be in the range of 41°F and 59°F. We suspect that the ship’s chilled water is actually much lower than 105°F, but we’ll need to know what it is as it will directly affect the chillers heat exchanger size and chiller configuration. If the water is in fact 105°F, a liquid-to-refrigerant-to-liquid chiller configuration may be considered, which will use a vapor cycle to reject heat to the ships chilled water.

Government Response: While we are being told that the ship regularly provides chilled water at temperatures lower that the specified maximum below, we have not been able to obtain documented values at this time. Please defer to the older values. We expect them to be lower but can’t officially qualify now.