Questions and Answers.docx

DOCX document 15 KB Posted

Attached to
6, 500ft-lbs. Force and Torque Calibrators
Solicitation number
N6426725R1021
Issued by

About this file

This document is a Questions and Answers file for a Department of the Navy solicitation for 6,500 ft-lbs Force and Torque Calibrators. The Q&A reveals key details about the procurement, including that this is a new contract with no incumbent, and clarifies technical specifications. Specifically, the calibrators are expected to perform cable tensiometer calibration from 5 to 2,400 lbf, with a requirement for a test system kit to cover this range. An amendment (Amendment 0001) has been issued, and the government is considering a potential 10-business-day extension to the proposal timeline. The solicitation is an all-or-none requirement for a single Indefinite Delivery/Indefinite Quantity (IDIQ) contract, with proposals to be submitted electronically in PDF or MS Word format. Contractors must be registered in the System for Award Management (SAM) to be eligible.

View the file

Other files

File Type Posted
RFP_N6426725R1021.pdf PDF
Questions and Answers.docx DOCX document
Questions and Answers.docx DOCX document
Attachment 03_Cross Reference Matrix v2.xlsx XLSX spreadsheet
Amendment N6426725R10210001.pdf PDF
Attachment 01_PAX CSS FY20-0008 February 2025.pdf PDF
Attachment 03_Cross Reference Matrix.xlsx XLSX spreadsheet
RFP_N6426725R1021.pdf PDF
Exhibit B.pdf PDF
Attachment 02_NAVSEA Subcontracting Plan Checklist.pdf PDF
Exhibit A.pdf PDF
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

6,500ft-lbs Force and Torque Calibrators RFP Questions and Answers

Q1: Is this is a brand-new contract or is there an incumbent performing these services.

A1: This is a new contract. There is no incumbent.

Q2: Requesting a 10-business-day extension.

A2: An extension is being discussed with the Contracting Officer.

Q3: Attacment_03 Cross Reference Matrix states, “up to 4000 ft lb”. Do you need 4000 or 6500 as stated in other attachments?

A3: 6,500. See Amendment 0001.

Q4: Is the 6,500 ft-lbs Force and Torque Calibrators expected to perform cable tensiometer calibration?

A4: Yes, the 6,500 ft-lbs Force and Torque Calibrators are expected to perform cable tensiometer calibration from 5 to 2,400lbf per paragraph 2.6.3 of the advertised CSS. Additionally, the calibration bench shall have a test system kit in order to test cable tensiometers across the range 5 to 2,400lbf per paragraph 3.1.4.