GDS_100pct DRAFT_Site 14_Vol. 14.8.pdf
PDF 4 MB Posted
- Solicitation number
- N62742GDSCC
About this file
This document is a draft Request for Proposal (RFP) for the construction (design-bid-build) of a command center, associated 9 MW (N+2) mission power generation facility, and a switchgear building at Andersen Air Force Base in Guam. The total estimated cost is between $250,000,000 to $500,000,000.
The key details include:
- The draft plans and specifications are being released for industry review and comment to improve understanding of the government's requirements and industry capabilities prior to issuing the final RFP.
- The draft RFP is for construction of facilities appropriate for the tropical climate, while meeting wind and seismic requirements.
- Comments on the draft RFP are due by 2:00 PM HST on 15 August 2024. The government will not provide responses to the comments received.
- This is not an announcement of a solicitation, and the government does not intend to award a contract based on this draft or pay for review comments.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V F
A C
P A
C
IF
IC
M
A K
A L A
P A
H
A W
A
II
AS NOTED
P R
O J E
C T
S
IT
E
C O
M M
A N
D C
E N
T E
R
N A
V F
A C
P A
C
IF
IC
1812861
KYM
JC
Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813
A/E Task Order No. N6274223F0324
FOR REVIEW
ONLY
Name
Registration Number #
These documents are for Design Review and not intended for
Construction Bidding or Permit Purposes. They were prepared by, or under the supervision of:
Date
SEAL
24 JUN 2024
A N
D E
R S
E N
A
IR
F O
R C
E B
A S
E
KYM
AWK/DMK
/2
/2
:3 :4
A
M
C U s e rs
\l a r6
\D o c u m e n ts
\P
G L a re s
.r v t
14GI-G-015
C O
V E
R S
H E
E T
DCT
EL EL
G U
A M
G
I- G
-0
FINAL DESIGN SUBMITTAL
100% DESIGN SUBMITTAL
VICINITY MAP PROJECT LOCATION MAP
VOLUME 14.8 - ACCESS CONTROL
PRIME CONSULTANT
CONSULTANTS
GENERAL NOTES AND REQUIREMENTS
VOLUME DESCRIPTION
VOL 14.1 GENERAL & SITE
VOL 14.2
VOL 14.4
COMMAND CENTER (GENERAL & STRUCTURAL)
VOL 14.5 COMMAND CENTER ( GENERAL, TELECOMMUNICATIONS, AUDIO VISUAL & SECURITY)
COMMAND CENTER ( GENERAL & ELECTRICAL)
VOL 14.3 COMMAND CENTER (GENERAL, ARCH, INTERIOR, FIRE PROTECTION, PLUMBING & MECHANICAL )
VOL 14.6 POWER PLANT (GENERAL, STRUCT, ARCH, INTERIOR, FIRE PROTECTION & PLUMBING
VOL 14.7 POWER PLANT (GENERAL, MECHANICAL, ELECTRICAL, TELECOMMUNICATIONS & SECURITY
VOL 14.8 ACCESS CONTROL
PROJECT 693
SITE 14 COMMAND CENTER
ANDERSEN AIR FORCE BASE, GUAM
PLAN NORTH PLAN NORTH
Jacobs/B&V, a Joint Venture (Federal Services)
BLACK & VEATCH
SHEET REFERENCES WITHOUT SITE NUMBER AND BUILDING ID (I.E. FRIST FOUR
CHARACTERS) ARE INDICATING SHEETS WITHIN THE SAME SERIES OF DRAWINGS
OR TO GENERAL SHEETS, AS APPLICABLE.
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V F
A C
P A
C
IF
IC
M
A K
A L A
P A
H
A W
A
II
AS NOTED
F Y
P
R O
J E
C T
G D
S C
O M
M A
N D
C E
N T
E R
N A
V F
A C
P A
C
IF
IC
1764210
KYM
JC
Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813
A/E Task Order No. N6274223F0324
FOR REVIEW
ONLY
Name
Registration Number #
These documents are for Design Review and not intended for
Construction Bidding or Permit Purposes. They were prepared by, or under the supervision of:
Date
SEAL
24 JUN 2024
A N
D E
R S
E N
A
IR
F O
R C
E B
A S
E
KYM
AWK/DMK
/2
/2
:1 :4
A
M
C R e v it \l o c a l_
\P
G
T a rr D
C b v .c o m
.r v t
14GI-G-016
S H
E E
T
IN
D E
X
ELDCT DCT
G U
A M
G I-
G -0
100% DESIGN SUBMITTAL
SITE 14 - ACCESS CONTROL SHEET INDEX - VOL 14.8
SHEET
NO.
NAVFAC
DWG. NO. SHEET NUMBER SHEET NAME
GENERAL
0 14AC-GI001 ACCESS CONTROL - BUILDING CODE ANALYSIS
0 14AC-GI101 ACCESS CONTROL - LIFE SAFETY PLAN
STRUCTURAL
0 14AC-S-001 ACCESS CONTROL - SYMBOLS, LEGENDS AND GENERAL NOTES
0 14AC-S-002 ACCESS CONTROL - STRUCTURAL NOTES
0 14AC-SB101 ACCESS CONTROL - FOUNDATION PLAN
0 14AC-SF121 ACCESS CONTROL - ROOF FRAMING PLAN
0 14AC-S-201 ACCESS CONTROL - FRAMING ELEVATIONS
0 14AC-S-401 ACCESS CONTROL - ELECTRICAL YARD - PLANS AND
ELEVATIONS
0 14AC-S-402 ACCESS CONTROL - ELECTRICAL YARD- SECTIONS AND DETAILS
0 14AC-S-501 ACCESS CONTROL - CONCRETE SCHEDULES
0 14AC-S-502 ACCESS CONTROL - TYPICAL CONCRETE DETAILS
0 14AC-S-512 ACCESS CONTROL - CANOPY ROOF SECTIONS AND DETAILS
ARCHITECTURE
0 14AC-AE101 ACCESS CONTROL - PLANS
0 14AC-A-201 ACCESS CONTROL - ELEVATIONS AND SECTIONS
0 14AC-A-401 ACCESS CONTROL - SITE ELECTRICAL YARD
0 14AC-A-501 ACCESS CONTROL - DOOR SCHEDULE, DETAILS AND ISOMETRIC
VIEWS
ELECTRICAL
0 14AC-E-001 ACCESS CONTROL - ELECTRICAL SYMBOLS, LEGEND,
ABBREVIATIONS, AND NOTES
0 14AC-EP101 ACCESS CONTROL - ELECTRICAL PLANS
0 14AC-EP501 ACCESS CONTROL - ELECTRICAL DETAILS
0 14AC-E-701 ACCESS CONTROL - ELECTRICAL DIAGRAMS AND SCHEDULES
COMMUNICATIONS
0 14AC-TT001 ACCESS CONTROL - COMMUNICATIONS SYMBOLS, LEGEND,
ABBREVIATIONS, AND NOTES
0 14AC-TT101 ACCESS CONTROL - FLOOR PLAN - COMMUNICATIONS
0 14AC-TT501 ACCESS CONTROL - COMMUNICATIONS DETAILS
SECURITY
0 14AC-TY101 ACCESS CONTROL - FLOOR PLAN - SECURITY
SITE 14 - GENERAL SHEET INDEX - VOL. 14.8
SHEET
NO.
NAVFAC
DWG. NO. SHEET NUMBER SHEET NAME
GENERAL
0 14GI-G-015 COVER SHEET
0 14GI-G-016 SHEET INDEX
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
G U
A M
P R
O J E
C T
S
IT
E
C
O M
M A
N D
C E
N T
E
FLOOR, ROOM OR
SPACE DESIGNATION
MINIMUM
NUMBER OF EXITS
TRAVEL DISTANCE
BUILDING
REQUIRED SHOWN
ON PLAN
ALLOWABLE TRAVEL
DISTANCE (LSC)
ARRANGEMENT MEANS
OF EGRESS
ACTUAL TRAVEL
DISTANCE SHOWN ON
PLANS
REQ'D DISTANCE
BETWEEN EXIT
DOORS
ACTUAL DISTANCE
SHOWN ON PLANS
EXEMPT N/A EXEMPT EXEMPT N/A
COMMON PATH OF TRAVEL
• NON-SPRINKLERED BUSINESS OCCUPANCIES (LSC 11.2.2.6)
EXEMPT
DEAD END PATH OF TRAVEL
• NON-SPRINKLERED BUSINESS OCCUPANCIES (LSC 11.2.2.6)
EXEMPT
TOTAL TRAVEL DISTANCE
• NON-SPRINKLERED BUSINESS OCCUPANCIES (LSC 11.2.2.6)
EXEMPT
BUILDING CODE AND LIFE SAFETY ANALYSIS
COMMON PATH, DEAD END, & TOTAL TRAVEL DISTANCE ANALYSIS (LSC SECTION 38.2.5)
REQUIRED ACTUALTRAVEL DISTANCE REQUIREMENT
MEANS OF EGRESS SUMMARY (LSC SECTION 38.2)
N/A
23'-6"
23'-6"
APPLICABLE CODES AND DESIGN CRITERIA
STANDARD TITLE REVISION DATE NOTES
UFC 1-200-01 GENERAL BUILDING REQUIREMENTS 12 JUNE 2023 CHANGE 2
UFC 3-600-01* FIRE PROTECTION ENGINEERING FOR FACILITIES 6 MAY 2021
IBC INTERNATIONAL BUILDING CODE 2021 APPLICABLE TO ALLOWABLE
CONSTRUCTION TYPE, BUILDING
HEIGHT, BUILDING AREA, BUILDING
SEPARATION DISTANCE,
OCCUPANCY SEPARATION AND
ALL ASSOCIATED REQUIREMENTS
NFPA 101 LIFE SAFETY CODE (LSC) 2024
* UFC 3-600-01 GENERALLY REQUIRES CONSTRUCTION ISSUES TO COMPLY WITH IBC CRITERIA AND LIFE SAFETY/EGRESS ISSUES TO MEET THE REQUIREMENTS OF LSC. CONFLICTS BETWEEN THE IBC AND LSC RELATED TO FIRE RESISTANCE ARE REQUIRED TO COMPLY WITH LSC
CRITERIA AND APPLICABLE PROVISIONS OF THE UFC CODE (UFC 3-600-01 § 2-1.1).
BUILDING DESCRIPTION
TYPE OF CONSTRUCTION II-B
NUMBER OF STORIES 1
BUILDING HEIGHT 11-9"
NUMBER OF
STORIES
OCCUPANCY
AND USE
(A)
ACTUAL AREA (SF)
(B)
ALLOWABLE AREA
(SF)
(C)
AREA FOR FRONTAGE
INCREASE (100% OPEN)
(E)
ALLOWABLE AREA
ALLOWABLE AREA (IBC TABLE 506.2)
CHANGE 6
NFPA 1 FIRE CODE 2024 --
APPLICABLE TO FIRE/SMOKE
RESISTANCE RATING OF INTERIOR
NON-LOAD BEARING PARTITIONS
(OTHER THAN OCCUPANCY
SEPARATIONS REQUIRED BY IBC),
MEANS OF EGRESS, INTERIOR
FINISH, FEATURES OF FIRE
PROTECTION, AND ASSOCIATED
REQUIREMENTS
OCCUPANCY GROUPS B
1 B 870 23,000 -- 23,000
ADDITIONAL FIRE RESISTIVE RATED CONSTRUCTION REQUIREMENTS (LSC)
NOTESBUILDING
ELEMENT/HAZARD
DESCRIPTION
HOURLY RATING
REQUIRED PROVIDED
OCCUPANCY CLASSIFICATIONS
BUSINESS
LSC
GROUP B
AREA
IBC
NEW BUSINESS
(CHAPTER 38)
USE AND OCCUPANCY CLASSIFICATIONS
NO ADDITIONAL FIRE-RESISTANCE RATED CONSTRUCTION REQUIREMENTS BY UFC 3-600-01 OR NFPA 101.
TOTAL -- 23,000 -- 23,000
ALLOWABLE HEIGHT (IBC TABLE 504.3 AND 504.4)
ALLOWABLE
BUILDING HEIGHT 55'-0"
ACTUAL
NUMBER OF STORIES 3 1
FIRE RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS OF TYPE II-B
BUILDING BASED ON FIRE SEPARATION DISTANCE (IBC TABLE 602)
FIRE SEPARATION DISTANCE TO LOT LINE USE GROUP B
FSD < 5 FT
5FT ≥ FSD < 10FT
FSD ≥ 10FT (PROVIDED)
1 HR
1 HR
0 HR
NOTES
STRUCTURAL FRAME, INCLUDING COLUMNS,
GIRDERS, TRUSSES
BUILDING ELEMENT HOURLY RATING
REQUIRED PROVIDED
BEARING WALLS
EXTERIOR
INTERIOR
NONBEARING WALLS AND PARTITIONS
EXTERIOR WALLS
*NOT LESS THAN THE FIRE RESISTANCE RATING BASED ON
THE FIRE SEPARATION DISTANCE FROM BUILDING 235
(SEE IBC TABLE 602)
*NOT LESS THAN THE FIRE RESISTANCE RATING BASED ON
THE FIRE SEPARATION DISTANCE FROM BUILDING 235
(SEE IBC TABLE 602)
FLOOR CONST. INCLUDING SUPPORTING
BEAMS AND JOISTS
ROOF CONSTRUCTION INCLUDING
SUPPORTING BEAMS AND JOISTS
TYPE II-B FIRE RESISTANCE RATINGS OF STRUCTURAL ELEMENTS (IBC TABLE 601)
0 0
0 0
0 0
0 0
0 0
0 0
11'-9"
OCCUPANT LOAD FACTOR
(FT2/PER PERSON)
USE
APPLICABLE OCCUPANT LOAD FACTORS (UFC TABLE 10-1 AND LSC TABLE 7.3.1.2)
150BUSINESS USE
ACC. CTRL. POINT BUSINESS
TOTAL
870 150 6
-- 870 -- 6
LSC CALCULATED BUILDING OCCUPANT LOAD 6
AREA OCCUPANCY APPROX. AREA OCCUPANT LOAD
FACTOR
OCCUPANT LOAD
FIRST FLOOR
NUMBER OF EXITS AND CAPACITY (LSC SECTION 38.2.3 AND 38.2.4)
FLOOR LEVEL
FIRST FLOOR
REQUIRED EXIT CAPACITY NUMBER OF EXITS REQUIRED
EXEMPT (PER LSC SECTION 11.2.2.3) EXEMPT (PER LSC SECTION 11.2.2.4.1)
CALCULATED OCCUPANT LOADS (LSC SECTION 38.1.7 AND TABLE 7.3.1.2)
INTERIOR FINISH CLASSIFICATION LIMITS (LSC SECTION 38.3.3)
NOTESINTERIOR FINISH FOR
BUSINESS
CLASSIFICATION
REQUIRED PROVIDED
EXITS
FINISH FLOOR
A OR B
I OR II
A* I**
*LATEX PAINTED CMU WALL.
**CLEAR CONCRETE SEALED FLOOR.
EXIT ACCESS CORRIDORS
FINISH FLOOR
A, B OR C
I OR II
N/A NO FIRE RATED INTERIOR
SEPARATIONS.
NO GYPSUM, CEILINGS, ETC.A, B OR C
N/A
N/AOTHER SPACES
FINISH FLOOR
SYSTEM REQUIRED?
AUTOMATIC SPRINKLER
GOVERNING CODE/STANDARD
FEATURES OF FIRE PROTECTION
PROVIDED?
FIRE PUMP
FIRE HYDRANTS
FIRE ALARM
MASS NOTIFICATION
FIRE EXTINGUISHER
STANDPIPE
SMOKE CONTROL
NO
NO
NO
NO
YES
NO
NO NO
NO
YES
NO
NO
NO
NO
YES YES NFPA 1 (2024) & UFC 3-600-01
23'-6"
NFPA 1 (2024) & NFPA 10 (2022)
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
FOR REVIEW
ONLY
N A
V F
A C
P A
C
IF
IC
Name
Registration Number #
These documents are for Design Review and not intended for
Construction Bidding or Permit Purposes. They were prepared by, or under the supervision of:
Date
TEXAS REGISTERED ENGINEERING FIRM F-2966
BRADY BUSS
CA FP2199
100% DESIGN SUBMITTAL
M A
K A
L A
P A
H
A W
A
II
AS NOTED
A/E INFO
SEAL
G U
A M
Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813
A/E CONTRACT NO. N62478-20-D-5036
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
BB HLKC
24 JUN 2024
N A
V F
A C
P A
C
IF
IC
JC
1764210
AWK/DMK
KYM
JC
A/E Task Order No. N6274223F0324
F Y
P
R O
J E
C T
G
D S
C O
M M
A N
D C
E N
T E
R
A N
D E
R S
E N
A
IR
F O
R C
E B
A S
E
/1
/2
:2 :4
P
M ft w fi l1
\P ro je c ts
\D F
W \B
L D
G \N
A V
F A
C P
A C
-C U
I\ D
D o G
P -6
S it e
\7
W o rk in g D o c u m e n ts
\7
M o d e ls R
\7
.0 F ir e
P ro te c ti o n
\B a s e \P
-1 A
C -F
-3 D
.r v t
14AC-GI001
A C
-G I0
A C
C E
S S
C O
N T
R O
L
B U
IL
D
IN
G
C O
D E
A N
A
LY
S
IS
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
G U
A M
P R
O J E
C T
S
IT
E
M
M A
N D
C E
N T
S
S
S
S
S
1 2
B
A
TD
23' - 6"
TD
23' - 6"
SWINGING MAN DOOR WITH FAILSAFE
PUSH-BUTTON EXIT PERMITS FREE
ACCESS FROM SECURE TO NON-SECURE
SIDE.
SECURE ACCESS TURNSTILES
FAIL SECURE IN EITHER
DIRECTION. SECURE ACCESS
TURNSTILES DO NOT
OBSTRUCT ANY REQUIRED
MEANS OF EGRESS IN
ACCORDANCE WITH LSC
7.2.1.11.1.
S E
C U
R E
N O
N -S
E C
U R
E
/ 33 / 33
MULTIPURPOSE FIRE
EXTINGUISHER PER NFPA 1.
A. FOR BUILDING CODE ANALYSIS REFER TO 14AC-GI001.
B. FOR CODE COMPLIANCE SITE PLAN REFER TO 14GI-G-024.
C. REFER TO 14GI-G-024 FOR EXIT DISCHARGE MUSTER
POINTS FOR EACH SITE.
HATCH
OCCUPANCY
(USE)
OCCUPANCY LOAD
FACTOR
OCCUPANCY LEGEND
(NONE) B (BUSINESS)
S-2 (STORAGE) 500 SQFT/PERSON
150 SQFT/PERSON
2 HR FIRE
3 HR FIRE
ROOM NAME/NUMBER
& AREA
TRAVEL DISTANCE
COMMON PATH
DEAD END
/ 00
ACTUAL
OCCUPANTS
OCCUPANT LOAD
CAPACITY
EGRESS INDICATOR:
150 SF
PATH LENGTH
PLAN SYMBOLS:
TRAVEL DISTANCE: A
1' - 0"
1 HR FIRE
WALL SYMBOLS:
4 HR FIRE
SMOKE
FIRE EXTINGUISHER
TYPES:
RE: FLR PLANS FOR CABINET STYLE / 00
1 HR SMOKE & FIRE
2 HR SMOKE & FIRE
3 HR SMOKE & FIRE
4 HR SMOKE & FIRE
WATER
FOAM
CO2
CLEAN AGENT
MULTI-PURPOSE DRY
CHEMICAL
LIQUID GAS
ELECTRIC
METAL FIRE
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
FOR REVIEW
ONLY
N A
V F
A C
P A
C
IF
IC
Name
Registration Number #
These documents are for Design Review and not intended for
Construction Bidding or Permit Purposes. They were prepared by, or under the supervision of:
Date
TEXAS REGISTERED ENGINEERING FIRM F-2966
BRADY BUSS
CA FP2199
100% DESIGN SUBMITTAL
M A
K A
L A
P A
H
A W
A
II
AS NOTED
A/E INFO
SEAL
G U
A M
Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813
A/E CONTRACT NO. N62478-20-D-5036
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
BB HLKC
24 JUN 2024
N A
V F
A C
P A
C
IF
IC
JC
1764210
AWK/DMK
KYM
JC
A/E Task Order No. N6274223F0324
F Y
P
R O
J E
C T
S
C O
M M
A N
D C
E N
T E
R
A N
D E
R S
E N
A
IR
F O
R C
E B
A S
E
/1
/2
:4 :5
P
M
C R e v it L o c a l_
M o d e ls
\2 \P
-1
A
C -F
-3 D k e v in
.c o n ro y E
A S
J .r v t
14AC-GI101
A C
-G I1
A C
C E
S S
C O
N
TR
O L
LI
F E
S A
F E
TY
P
LA
N
TRAVEL DISTANCE SUMMARY
ID ACTUAL MAXIMUM
1 23' - 6" EXEMPT
2 23' - 6" EXEMPT
1/8" = 1'-0" A1
ACCESS CONTROL POINT LIFE SAFETY PLAN
PLAN
NORTH
14CC-A-101
SITE #
BUILDING ID DISCIPLINE
CONSECUTIVE NUMBERS
SITE #
SITE 01
SITE 02
SITE 14
BUILDING ID
AC - ACCESS CONTROL POINT
CC - COMMAND CENTER
FP - FIRE PUMP BUILDING
GI - GENERAL
PP - POWER PLANT
SF - SECURITY FORCE
ST - SITE
1/8" = 1'-0" 0 8' 16' 24'4'
GENERAL SHEET NOTES
GRAPHIC SCALE(S)
LEGEND
SHEET NAMING CONVENTIONSHEET NAMING CONVENTION
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
G U
A M
P R
O J E
C T
S
IT
E
M
M A
N D
C E
N T
STRUCTURAL SYMBOLS
ELEVATION POINT (TOP OF
ELEMENT INDICATED)
SURFACE - SLOPE (2) WAYS
SURFACE - SLOPE DOWN
SURFACE - STEPPED
SURFACE - SLOPE UP
WORKPOINTWP
(DIRECTION OF SPAN)
SLOPE
INDICATOR
STRUCTURAL ARROW
PRECAST
CONCRETE
CAST-IN-PLACE
CONCRETE
EL XXX' - 0"
T/
A. BUILDING AND DESIGN CODES:
1. UNIFIED FACILITIES CRITERIA.
a. UFC 1-200-01, DOD BUILDING CODE (CHANGE 2, 12 JUNE 2023)
b. UFC 3-301-01, STRUCTURAL ENGINEERING (11 APRIL 2023)
c. UFC 4-010-01, DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS (CHANGE 2, 30 JULY 2022)
d. UNITED FACILITIES GUIDE SPECIFICATIONS (UFGS)
2. IBC, INTERNATIONAL BUILDING CODE (2021)
3. ASCE 7-16, MINIMUM DESIGN LOADS AND ASSOCIATED CRITERIA FOR BUILDINGS AND OTHER
STRUCTURES (2016).
4. ACI 318-19; BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (2019).
5. CRSI MANUAL OF STANDARD PRACTICE, 29TH EDITION, 3RD PRINTING (2018)
B. DESIGN LOADS:
UNIFORM LOAD CONCENTRATED LOAD
1. LIVE LOADS:
2. DEAD LOAD (SUPERIMPOSED) 10 PSF
3. ROOF LIVE LOAD 20 PSF 300 LBS
4. WIND LOADS
1. ULTIMATE DESIGN WIND SPEED (3 SECOND GUST) Vult - 195 MPH
2. NOMINAL DESIGN WIND SPEED (3 SECOND GUST) Vasd - 151 MPH
3. RISK CATEGORY - II
4. EXPOSURE - D
5. OPEN BUILDING
6. TOPOGRAPHICAL FACTOR, Kzt - 1.5
7. SUPERIMPOSED DEAD LOAD OF 10 PSF FOR WIND UPLIFT DESIGN
5. SEISMIC LOADS:
1. RISK CATEGORY - II
2. SEISMIC IMPORTANCE FACTOR = 1.0
3. MAPPED SPECTRAL RESPONSE ACCELERATIONS - Ss = 2.233g, S1 = 0.545g (REDUCED
BY 20% BASED ON SITE-SPECIFIC GROUND MOTION CONDUCTED BY AECOM PER ASCE
7-16, CHAPTER 21)
4. SITE CLASS - C
5. SPECTRAL RESPONSE COEFFICIENTS - Sds = 1.786g, Sd1 = 0.529g
6. SEISMIC DESIGN CATEGORY D
7. SEISMIC FORCE RESISTING SYSTEM:
SPECIAL REINFORCED CONCRETE MOMENT FRAME
8. RESPONSE MODIFICATION FACTOR - R= 8
9. SYSTEM OVERSTRENGTH FACTOR, Ω0= 3
10. DEFLECTION AMPLIFICATION FACTOR, Cd= 5.5
11. ANALYSIS PROCEDURE - EQUIVALENT LATERAL FORCE PROCEDURE
12. BASE SHEAR - V = CsW = 0.223W = 51.02 KIPS
6. SNOW LOADS:
a. GROUND SNOW LOAD, pg - 0 PSF
b. FROST DEPTH PENETRATION - 0 INCH
7. RAIN LOADS:
a. RAIN INTENSITY,
i. 15-MINUTE RAINFALL INTENSITY 9.6 IN/HR
ii. 60-MINUTE RAINFALL INTENSITY 4.8 IN/HR
C. GENERAL REQUIREMENTS:
1. SPECIFICATIONS ARE PART OF THE CONSTRUCTION DOCUMENTS AND MUST BE USED IN
CONJUNCTION WITH THE DRAWINGS.
2. VERIFY EXISTING CONDITIONS AND DIMENSIONS PRIOR TO BEGINNING WORK OR FABRICATING
MATERIALS. NOTIFY GOVERNMENT OF DISCREPANCIES BEFORE PROCEEDING WITH ANY PHASE
OF WORK.
3. DO NOT SCALE DRAWINGS FOR THE PURPOSE OF ESTABLISHING DIMENSIONS.
4. DETAILS LABELED "TYPICAL DETAILS" ON DRAWINGS APPLY TO SITUATIONS OCCURRING ON THE PROJECT THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY DETAILED. SUCH DETAILS
APPLY WHETHER OR NOT DETAILS ARE REFERENCED AT EACH LOCATION. NOTIFY GOVERNMENT
OF CONFLICTS REGARDING APPLICABILITY OF "TYPICAL DETAILS".
5. DO NOT LOAD THE SLAB ON GRADE OR SUSPENDED SLAB WITH ERECTION CRANES OR ERECTION
EQUIPMENT. THE SLABS HAVE NOT BEEN DESIGNED FOR CRANE LOADS AND WILL REQUIRE AN
INCREASE IN THICKNESS AND/OR REINFORCEMENT. OBTAIN GOVERNMENT APPROVAL ON
PROPOSED CRANE SUPPORT PLAN PRIOR TO COMMENCING WORK.
6. DO NOT STORE OR STACK CONSTRUCTION MATERIALS ON POURED OR ERECTED ROOF IN EXCESS
OF 50 PERCENT OF LIVE LOAD. GENERAL CONTRACTOR MUST ENSURE THAT ALL SUB-
CONTRACTORS ARE INFORMED OF LOADING RESTRICTIONS. AVOID IMPACT WHEN PLACING
MATERIALS ON POURED OR ERECTED FLOORS OR ROOF.
7. THE CONTRACT STRUCTURAL DOCUMENTS REPRESENT THE FINISHED STRUCTURE. THE
CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION. PROVIDE ALL
MEASURES REQUIRED TO PROTECT THE STRUCTURE, WORKMEN, AND OTHER PERSONS DURING
CONSTRUCTION; INCLUDING BRACING, SHORING FOR CONSTRUCTION EQUIPMENT, SHORING FOR
THE BUILDING, FORMS, AND SCAFFOLDING, SHORING OF RETAINING WALLS AND OTHER
TEMPORARY SUPPORTS AS REQUIRED.
8. ALL DIMENSIONS SHOWN MUST BE VERIFIED AGAINST ARCHITECTURAL DRAWINGS. IF ANY
CONFLICT OF DIMENSIONS BETWEEN STRUCTURAL AND ARCHITECTURAL DRAWINGS OCCUR,
THEY MUST BE BROUGHT TO THE ATTENTION OF THE GOVERNMENT BEFORE PROCEEDING WITH
THE WORK.
GENERAL NOTES
A. REFER TO THE FOLLOWING GENERAL NOTES AND SPECIFICATIONS FOR GENERAL REQUIREMENTS OF
EARTHWORK, OVER EXCAVATION, SUBGRADE PREPARATION, FILL AND COMPACTION, WATERPROOFING
AND OTHER PERTINENT REQUIREMENTS AND INFORMATION.
B. FOUNDATION DESIGN IS BASED UPON THE GEOTECHNICAL REPORT FOR FLEMING HEIGHTS SITE (DoG 14
SITE) BY ESC PACIFIC, DATED DECEMBER 16, 2023.
C. FOOTINGS ARE DESIGNED FOR AN ALLOWABLE NET BEARING PRESSURE OF 4200 PSF FOR GRAVITY LOADS.
AN ALLOWABLE NET BEARING PRESSURE OF 5600 PSF CAN BE USED FOR LOAD COMBINATIONS INCLUDING
SHORT TERM LOADS (SEISMIC AND WIND).
D. RESISTANCE TO LATERAL LOADS
1. FRICTION ACROSS FOUNDATION BOTTOMS: 0.55
2. PASSIVE SOIL RESISTANCE AGAINST ONE FACE OF THE FOOTINGS: 360 PCF
E. MAINTAIN SUBGRADE AND FILL MOISTURE CONTENT UNTIL FOUNDATIONS ARE PLACED.
F. CONTRACTOR MUST ARRANGE FOR INDEPENDENT TESTING AGENCY TO MONITOR CUT AND FILL OPERATIONS, AND PERFORM FIELD DENSITY AND MOISTURE CONTENT TESTS TO VERIFY COMPACTION
AND APPROVE FOOTING SUBGRADE PRIOR TO PLACING CONCRETE.
G. DURING CONSTRUCTION, APPROPRIATE SURFACE AND SUBSURFACE DRAINAGE MUST BE PROVIDED TO AVOID SURFACE PONDING. DO NOT PLACE FOOTINGS OR SLABS AGAINST SUBGRADE CONTAINING
FREE WATER.
H. KEEP OPEN EXCAVATIONS AROUND BUILDING DRY. BACKFILL AGAINST FOUNDATIONS AND GRADE BEAMS AS SOON AS PRACTICAL. PUMP WATER OUT OF OPEN EXCAVATIONS IF FLOODING PRIOR TO
BACKFILLING.
J. FORM SIDES OF FOOTINGS STRAIGHT AND TO SPECIFIED DIMENSIONS. EARTH FORMS WILL NOT BE
PERMITTED.
K. REFER TO CIVIL DRAWING 14AC-CG-401 FOR LIMITS OF EXCAVATIONS.
L. SITE PREPARATION AND GRADING
1. INITIALLY, CLEAR ANY VEGETATION FROM AREAS THAT WILL BE GRADED. THEREAFTER, STRIP
SURFACE SOIL WITH ROOTS AND REMOVE AWAY OR TEMPORARY STOCKPILE AT SELECTED
LOCATIONS ON THE SITE FOR LATER REUSE IN LANDSCAPING.
2. CUT EXISTING PAVEMENT IN A NEAT MANNER SO AS NOT TO DISTURB ADJOINING ASPHALT CONCRETE
PAVEMENT AND ITS BASE/SUBBASE. MINIMIZE DISTURBING FINAL EXPOSED SURFACES.
3. ADDITIONAL EXCAVATION – AFTER THE ABOVE IS COMPLETED, INCLUDING ANY REQUIRED
EXCAVATIONS, WITHIN THE PLANNED BUILDING FOOTPRINTS, CONCRETE WALKWAYS, AND
PAVEMENT AREAS, THE EXISTING UPPER SILTY LIMESTONE GRAVEL WITH SAND SUBGRADE, IF
TESTED TO HAVE LESS THAN 95 PERCENT OF ITS MODIFIED DRY DENSITY (MDD), MUST BE
EXCAVATED FOR RECOMPACTION OR REWORK TO ACHIEVE AT LEAST 95 PERCENT MDD OF THE
COMPACTED SOIL. THE MAXIMUM DEPTH OF REWORKING CAN BE LIMITED TO 2 FEET BELOW THE FOOTING BOTTOM ELEVATION, INCLUDING A MINIMUM 10 INCHES WIDER ALL AROUND THE FOOTING
EDGES. EXCAVATED UNSUITABLE MATERIAL INCLUDING OVER-SIZED ROCK FRAGMENTS (MORE
THAN 4 INCHES IN MAXIMUM SIZE) MUST BE REMOVED AWAY. IF NECESSARY, BRING IN
SUITABLE LIMESTONE SAND/GRAVEL WITH SOME SILT FOR BACKFILLING, MEETING THE
REQUIREMENTS OF SUITABLE BACKFILL MATERIAL.
4. EXCAVATED SILTY LIMESTONE GRAVEL WITH SAND CAN BE STOCKPILED SEPARATELY AT
SELECTIVE LOCATION(S), FOR POSSIBLE RE-USE.
5. PERFORM THE EXCAVATION AND RECOMPACTION UNDER THE OBSERVATION OF THE
GEOTECHNICAL ENGINEER.
FOUNDATION NOTES
M. FOUNDATION SUPPORT
1. THE PLANNED BUILDING MUST BE SUPPORTED ON SHALLOW SPREAD FOOTINGS AND/OR
CONTINUOUS FOOTINGS RESTING ON EITHER THE MODERATELY HARD TO HARD, NATIVE
CORALLINE LIMESTONE OR ON A LAYER OF UNIFORM, DENSELY COMPACTED LIMESTONE
SAND/GRAVEL SOIL FILL, HAVING AT LEAST 95 PERCENT OF ITS MDD, INCLUDING EXTENDING OUT
A MINIMUM OF 2 FEET WIDER AROUND THE FOOTINGS.
2. FOUNDATION SUBGRADE PREPARATION – THE FOLLOWING FOOTING SUBGRADE
PREPARATION MUST BE PERFORMED DURING CONSTRUCTION:
a) FOOTING BOTTOM EXCAVATION THAT EXPOSES SOFT TO MEDIUM STIFF, ELASTIC SILT OR
LOOSE TO MEDIUM DENSE GRAVEL/SAND, MUST BE EXCAVATED ENTIRELY UNTIL
REACHING STIFF TO VERY STIFF, ELASTIC SILT THAT TESTED TO HAVE A MINIMUM 90
PERCENT OF ITS MDD OR SAND/GRAVEL SOIL WITH AT LEAST 95 PERCENT MDD, TO A
DEPTH EQUAL TO A MINIMUM 1.5 TIMES THE WIDTH OF THE FOOTING DIRECTLY ABOVE,
INCLUDING A MINIMUM 10 INCHES WIDER ALL AROUND THE FOOTINGS. BACKFILL WITH
LIMESTONE SAND/GRAVEL SOIL HAVING AT LEAST 95 PERCENT OF ITS MDD IN 6 INCH
THICK COMPACTED LAYERS.
b) FOOTING BOTTOM EXCAVATION THAT EXPOSES DENSE TO VERY DENSE SILTY LIMESTONE
GRAVEL WITH SUBGRADE SOIL THAT IS TESTED TO HAVE AT LEAST 95 PERCENT OF ITS
MDD, THE EXPOSED SURFACE THAT WAS DISTURBED BY THE FOOTING EXCAVATION MUST
BE LIGHTLY SCARIFIED TO APPROXIMATELY 6 INCHES DEEP, MOISTURE CONDITIONED AS
NECESSARY AND RECOMPACTED TO AT LEAST 95 PERCENT OF ITS MDD.
c) FOOTING BOTTOM EXCAVATION THAT EXPOSES EITHER SILTY SANDY LIMESTONE GRAVEL
OR WEAK LIMESTONE THAT FAILS TO HAVE 95 PERCENT OF ITS MDD, MUST BE EXCAVATED
TO EXPOSE DENSE SOIL HAVING AT LEAST 95 PERCENT OF ITS MDD OR MODERATELY HARD
TO HARD CORALLINE LIMESTONE, TO A MAXIMUM DEPTH OF 2 FEET BELOW THE FOOTING
BOTTOM, INCLUDING AT LEAST 12 INCHES WIDER ALL AROUND THE AFFECTED FOOTING.
THEREAFTER SCARIFY THE FINAL EXPOSED SURFACE TO ABOUT 6 INCHES DEEP, MOISTURE
CONDITION AS NECESSARY, AND COMPACT TO AT LEAST 95 PERCENT OF ITS MDD. THEN
BACKFILL WITH LIMESTONE SAND/GRAVEL SOIL WITH SILT IN 8-INCH MAXIMUM LOOSE
LAYERS, MOISTURE CONDITION AS NECESSARY, AND COMPACT TO AT LEAST 95 PERCENT
OF ITS MDD. ALTERNATIVELY, THE BACKFILL CAN BE “FLOWABLE FILL” HAVING AT LEAST 600
POUNDS PER SQUARE INCH (PSI) 28-DAY COMPRESSIVE STRENGTH AND MUST BE
HARDENED WITHIN 8 TO 12 HOURS.
3. DEVELOP A PROBING AND GROUTING PROGRAM PRIOR TO CONSTRUCTION OF THE FOUNDATION.
IF GROUTING IS REQUIRED, GROUT MAY CONSIST OF A MIXTURE OF TWO PART SAND TO ONE
PART CEMENT (2:1) WITH SUFFICIENT WATER CONTENT TO OBTAIN A FLOWABLE MIXTURE THAT
IS ABLE TO BE PUMPED. CONTRACTOR TO SUBMIT A PROBING AND GROUTING PLAN FOR
APPROVAL TO INCLUDE DETAILS OF THE GROUT MIX, GROUTING METHODS AND ASSOCIATED
APPLIED PRESSURES
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
FOR REVIEW
ONLY
N
AV
FA
C
P
AC
IF
IC
Name
Registration Number #
These documents are for Design Review and not intended for
Construction Bidding or Permit Purposes. They were prepared by, or under the supervision of:
Date
TEXAS REGISTERED ENGINEERING FIRM F-2966
CESAR R. VALLENILLA
TX 83559
CV LFAG
100% DESIGN SUBMITTAL
M
AK
AL
AP
A, H
AW
AI
I
AS NOTED
A/E INFO
SEAL
GU
AM
Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813
A/E CONTRACT NO. N62478-20-D-5036
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
24 JUN 2024
N
AV
FA
C
P
AC
IF
IC
BC
1764210
AWK/DMK
KYM
JC
A/E Task Order No. N6274223F0324
FY
P R
O
JE
C T
G D
S C
O M
M
AN
D C
EN
TE
R
AN
DE
RS
EN
A
IR
F
OR
CE
B
AS
E
6/
/2
7:
:3
PM
C :\U se rs
\ra jb ah c\
D oc um en ts \P
3_
6-
AC
-S -3
D _C hr is tin a.
Ill ip ar am bi l.r vt
14AC-S-001
AC
-S -0
AC
CE
SS
C O
NT
RO
L
- S
YM
BO
LS
, L
EG
EN
DS
A
ND
G
EN
ER
AL
N O
TE
S
SCALEA1 ISOMETRIC VIEW
NOTE:
ACCESS CONTROL POINT MUST BE PLACED ON SITE 14. REFER TO CIVIL
DRAWINGS FOR BUILDING LOCATION AND ORIENTATION.
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
G U
A M
P R
O J E
C T
S
IT
E
M
M A
N D
C E
N T
CONCRETE NOTES
A. PROVIDE CONCRETE AS SHOWN BELOW. PROVIDE BATCH MIXING, TRANSPORTATION, PLACING AND
CURING OF CONCRETE IN ACCORDANCE WITH RECOMMENDATIONS OF ACI 301, ACI 318, AND ASTM C94.
USE PORTLAND CEMENT OF THE TYPES SPECIFIED BELOW, UNLESS OTHERWISE NOTED. PROVIDE ADMIXTURES AND SPECIAL REQUIREMENTS AS SPECIFIED. ALL CONCRETE IS EXPOSURE CATEGORY C2
PER TABLE 19.3.1.1 IN ACI 318.
1. NORMAL WEIGHT (150 PCF), F'c = 5,000 PSI CONCRETE AT 28 DAYS, TYPE II CEMENT WITH A
MAXIMUM WATER - CEMENTITIOUS RATIO OF 0.40.
a. FOUNDATIONS
b. CONCRETE NOT SPECIFICALLY COVERED
c. CAST IN PLACE, BEAMS, COLUMNS AND ROOF SLAB
B. CONCRETE MUST REACH THE FOLLOWING PERCENTAGES OF ITS 28 DAY COMPRESSIVE STRENGTH (F'c) BEFORE FORMS MAY BE REMOVED.
1. COLUMNS AND BEAMS - 40 PERCENT
2. SLAB - 40 PERCENT
C. PROVIDE CONCRETE MIXES DESIGNED BY A QUALIFIED TESTING LABORATORY FOR REVIEW AND
APPROVAL BY THE GOVERNMENT.
D. CHAMFER EXPOSED EDGES 3/4 INCH UNLESS OTHERWISE NOTED.
E. WIRE BRUSH AND CLEAN CONSTRUCTION JOINTS PRIOR TO POURING NEW CONCRETE.
F. REFERENCE THE APPROPRIATE DISCIPLINE'S DRAWINGS FOR SUBSLAB PIPING AND SLAB AND WALL
PENETRATIONS.
G. PROVIDE ADEQUATE STRUCTURAL FRAMING AS APPROVED BY GOVERNMENT FOR MECHANICAL
OPENINGS THROUGH THE SLABS, WALLS, AND FLOOR DECK. OPENINGS WILL NOT BE PERMITTED
THROUGH BEAMS UNLESS SPECIFICALLY DETAILED.
H. FOR CONDUIT OR PIPE INSTALLED HORIZONTALLY WITHIN SLAB-ON-GRADE, PROVIDE MAXIMUM OUTSIDE DIAMETER OF 30 PERCENT OF THE SLAB THICKNESS. PLACE CONDUIT OR PIPE BETWEEN THE TOP AND BOTTOM LAYERS OF REINFORCEMENT WITHIN THE CENTER THIRD OF THE SLAB. DO NOT
SPACE CONDUITS OR PIPES CLOSER THAN THREE DIAMETERS OR WIDTHS ON CENTER.
A. PROVIDE DETAILING, FABRICATION, AND INSTALLATION OF REINFORCING AND ACCESSORIES IN
ACCORDANCE WITH ACI 315 AND ACI 318.
B. PROVIDE STEEL REINFORCING BARS IN ACCORDANCE WITH ASTM A706 OR ASTM A615 GRADE 60 WITH
DUCTILITY REQUIREMENTS PER ACI 318-19 SECTION 20.2.2.5.
C. PROVIDE ANCHOR RODS CONFORMING TO THE STANDARDS OF ASTM F1554 GRADE 55 (WELDABLE)
UNLESS OTHERWISE NOTED.
D. COORDINATE PLACEMENT OF CAST-IN-PLACE EMBEDS AND ANCHOR RODS. SET ANCHOR RODS WITH A
TEMPLATE. SECURELY ATTACH EMBED ITEMS TO FORMWORK OR REINFORCING.
E. PROVIDE CLASS "B" REINFORCEMENT SPLICES FOR CONTINUOUS REINFORCEMENT. PROVIDE
STANDARD 90-DEGREE HOOKS IN ACCORDANCE WITH ACI 318, UNLESS OTHERWISE NOTED.
F. MAINTAIN THE FOLLOWING CONCRETE COVERAGE FOR REINFORCING STEEL UNLESS OTHERWISE
NOTED:
1. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH - 3 INCHES
2. CONCRETE EXPOSED TO EARTH OR WEATHER - 2 INCHES
3. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND:
a. SLABS - 2 INCHES
b. BEAMS AND COLUMNS: PRIMARY REINFORCEMENT, TIES, STIRRUPS - 2 INCHES
G. DO NOT WELD OR BEND REINFORCEMENT IN THE FIELD UNLESS SPECIFICALLY SHOWN OR APPROVED
BY GOVERNMENT.
H. USE LOW HYDROGEN ELECTRODES FOR WELDING OF REINFORCEMENT IN CONFORMANCE WITH
"WELDING REINFORCEMENT STEEL, METAL INSERTS AND CONNECTIONS IN REINFORCED
CONCRETE CONSTRUCTION", AMERICAN WELDING SOCIETY, AWS D1.4.
J. WHERE REQUIRED, PROVIDE DOWELS TO MATCH SIZE AND SPACING OF MAIN REINFORCING.
K. PROVIDE BAR SUPPORT ACCESSORIES IN ACCORDANCE WITH THE LATEST ACI MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES. SUPPORT BEAM REINFORCING ON
BEAM BOLSTERS SPACED NOT MORE THAN 4 FEET ON CENTER.
L. PROVIDE BAR SUPPORTS WITH PLASTIC COATED LEGS OR HOT DIP GALVANIZING AFTER FABRICATION FOR CONCRETE EXPOSED TO VIEW. PROVIDE STAINLESS STEEL BAR SUPPORTS FOR CONCRETE TO
RECEIVE A SANDBLAST FINISH.
M. LAP SPLICES MUST BE CONTACT CLASS B SPLICES. MECHANICAL COUPLERS MUST BE TYPE 2.
CONTRACTOR MUST ENSURE THAT PROPER CONCRETE COVER IS PROVIDE AT SPLICES AND
COUPLERS.
REINFORCING STEEL NOTES
ADDITIONAL SUBMITTALS
A. THE FOLLOWING ITEMS ARE DEFERRED SUBMITTALS, PENDING APPROVAL OF THE GOVERNMENT:
1. FORMS FOR CAST IN PLACE CONCRETE.
B. DEFERRED SUBMITTALS MUST BE ACCOMPANIED BY CALCULATIONS SIGNED BY A PROFESSIONAL
ENGINEER.
C. DEFERRED SUBMITTALS MUST BE SUBMITTED PRIOR TO INSTALLATION AND MUST BE APPROVED
BY THE GOVERNMENT FOR GENERAL CONFORMANCE TO THE DESIGN ASSUMPTION INTENT.
D. SUBMITTALS (WITH SHOP DRAWING REVIEW STAMPS ON THEM) MUST BE SUBMITTED TO THE
GOVERNMENT FOR REVIEW AND APPROVAL. A LETTER STATING THAT THE SUBMITTAL HAS BEEN
REVIEWED AND COORDINATED AND HAS BEEN FOUND ACCEPTABLE WITHOUT EXCEPTIONS MUST
ACCOMPANY THE SUBMITTAL.
SPECIAL INSPECTIONS
A. REFER TO PROJECT SPECIFICATION SECTION 01 45 35 A ND THE STATEMENT AND SCHEDULE OF
SPECIAL INSPECTIONS.
A. INSTALL EPOXY ANCHORED BOLTS AND DOWELS IN ACCORDANCE WITH CURRENT ICC-ES REPORTS OR
EQUIVALENT TESTING PROGRAM QUALIFYING THE ANCHORING SYSTEM FOR USE IN CRACKED
CONCRETE UNDER IBC 2021. CONTRACTOR MUST SUBMIT MANUFACTURER REPORTS INDICATING
COMPLIANCE WITH IBC/ACI.
B. INSTALL BOLTS AND DOWELS PERPENDICULAR TO THE FACE OF CONCRETE, UNLESS OTHERWISE
INDICATED IN THE DRAWINGS.
C. CREATE A TEMPLATE AT EACH BOLT CONNECTION LOCATION PRIOR TO FABRICATING HOLES IN
CONNECTION PLATES. MAKE TEMPLATE BY LOCATING EXISTING REBAR WITH PACHOMETER.
REPOSITION BOLTS A MAXIMUM OF 1 1/2" TO AVOID CONFLICTS WITH EXISTING REINFORCING.
D. DIAMETER OF DRILLED HOLES MUST BE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
DO NOT REDIRECT HOLES ALONG LENGTH OF BOLT.
E. DRILL HOLES IN CONTINUOUS OPERATION. BLOW DUST FROM THE HOLE USING COMPRESSED AIR.
F. FILL ABANDONED HOLES WITH EPOXY GROUT.
G. PROVIDE HOLES IN CONNECTION PLATES NO MORE THAN 1/8" LARGER THAN THE BOLT DIAMETER. IF
LARGER HOLES ARE NEEDED FOR ERECTION PURPOSES, PROVIDE PLATE WASHERS WELDED TO
CONNECTION PLATE TO TRANSFER THE BOLT LOAD.
H. INSTALLATION OF EPOXY ANCHORED DOWELS AND BOLTS MUST BE CONTINUOUSLY INSPECTED BY THE TESTING LABORATORY TO ENSURE THAT HOLES ARE OF THE PROPER DIAMETER AND LENGTH, ARE
PROPERLY CLEANED, AND THAT BOLTS ARE INSTALLED CORRECTLY.
J. EPOXY ANCHORED BOLTS MUST NOT BE USED IN OVERHEAD INSTALLATION.
EPOXY ANCHORED BOLT AND DOWEL NOTES
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
FOR REVIEW
ONLY
N
AV
FA
C
P
AC
IF
IC
Name
Registration Number #
These documents are for Design Review and not intended for
Construction Bidding or Permit Purposes. They were prepared by, or under the supervision of:
Date
TEXAS REGISTERED ENGINEERING FIRM F-2966
CESAR R. VALLENILLA
TX 83559
CV LFAG
100% DESIGN SUBMITTAL
M
AK
AL
AP
A, H
AW
AI
I
AS NOTED
A/E INFO
SEAL
GU
AM
Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813
A/E CONTRACT NO. N62478-20-D-5036
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
24 JUN 2024
N
AV
FA
C
P
AC
IF
IC
BC
1764210
AWK/DMK
KYM
JC
A/E Task Order No. N6274223F0324
FY
P R
O
JE
C T
G D
S C
O M
M
AN
D C
EN
TE
R
AN
DE
RS
EN
A
IR
F
OR
CE
B
AS
E
6/
/2
7:
:3
PM
C :\U se rs
\ra jb ah c\
D oc um en ts \P
3_
6-
AC
-S -3
D _C hr is tin a.
Ill ip ar am bi l.r vt
14AC-S-002
AC
-S -0
AC
CE
SS
C O
NT
RO
L
- S
TR
UC
TU
RA
L
NO
TE
S
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
G U
A M
P R
O J E
C T
S
IT
E
M
M A
N D
C E
N T
A
B
'-0
C3
14AC-S-201
13'-0"
C1
14AC-S-201
TYP
TYP
TYP
TYP
B1
14AC-S-502
B2
14AC-S-502
TYP
4'-0"
TYP
4'-0"
4'
- 0
4'
- 0
4'
- 0
4'
- 0
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
FOR REVIEW
ONLY
N
AV
FA
C
P
AC
IF
IC
Name
Registration Number #
These documents are for Design Review and not intended for
Construction Bidding or Permit Purposes. They were prepared by, or under the supervision of:
Date
TEXAS REGISTERED ENGINEERING FIRM F-2966
CESAR R. VALLENILLA
TX 83559
CV LFAG
100% DESIGN SUBMITTAL
M
AK
AL
AP
A, H
AW
AI
I
AS NOTED
A/E INFO
SEAL
GU
AM
Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813
A/E CONTRACT NO. N62478-20-D-5036
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
24 JUN 2024
N
AV
FA
C
P
AC
IF
IC
BC
1764210
AWK/DMK
KYM
JC
A/E Task Order No. N6274223F0324
FY
P R
O
JE
C T
G D
S C
O M
M
AN
D C
EN
TE
R
AN
DE
RS
EN
A
IR
F
OR
CE
B
AS
E
6/
/2
7:
:3
PM
C :\U se rs
\ra jb ah c\
D oc um en ts \P
3_
6-
AC
-S -3
D _C hr is tin a.
Ill ip ar am bi l.r vt
14AC-SB101
AC
-S B1
AC
CE
SS
C O
NT
RO
L
- F O
UN
DA
TI
O N
PL
AN14CC-A-101
SITE #
BUILDING ID DISCIPLINE
CONSECUTIVE NUMBERS
SITE #
SITE 01
SITE 02
SITE 14
BUILDING ID
AC - ACCESS CONTROL POINT
CC - COMMAND CENTER
FP - FIRE PUMP BUILDING
GI - GENERAL
PP - POWER PLANT
SF - SECURITY FORCE
ST - SITE
1/4" = 1'-0" 0 4' 8' 12'2'
GENERAL SHEET NOTES
GRAPHIC SCALE(S)
SHEET KEYNOTES
SHEET NAMING CONVENTIONSHEET NAMING CONVENTION
SCALE 1/4" = 1'-0"A2 FOUNDATION PLAN
A. FINISH GRADE OF 100'-0" CORRESPONDS TO A CIVIL
REFERENCE DATUM OF 521.45
B. REFER TO SHEETS 14AC-S-001 THRU 14AC-S-002 FOR
STRUCTURAL GENERAL NOTES.
C. REFER TO SHEETS 14AC-S-501 FOR TYPICAL CONCRETE
DETAILS.
D. REFER TO SHEET 14AC-S-001 FOR MATERIAL LEGENDS
01 21'X8'X2' FOOTINGS, TYP T/FTG ELV. 98'-0"
02 24"X24" CONCRETE COLUMN
03 24"X24" TIE BEAMS, T/TIE BEAM ELV. 98'-0"
PLAN
NORTH
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
G U
A M
P R
O J E
C T
S
IT
E
M
M A
N D
C E
N T
A
B
EOS
1'-0"
13'-0" 14'-0" EOS
1'-0"
C3
14AC-S-201
'-0
SLOPE DOWN
EO
S
1' -0
'-0
EO
S
1' -0
29'-0"
T/ROOF 111' - 9"
T/ROOF 110' - 7"
TYP
C2
14AC-S-512
C1
14AC-S-512
C1
14AC-S-201
B1
14AC-S-512
1'-8"
C3
14AC-S-512
B1 B2
B1 B2
B3 B4 B5
C2
14AC-S-512
B3
14AC-S-512
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
FOR REVIEW
ONLY
N
AV
FA
C
P
AC
IF
IC
Name
Registration Number #
These documents are for Design Review and not intended for
Construction Bidding or Permit Purposes. They were prepared by, or under the supervision of:
Date
TEXAS REGISTERED ENGINEERING FIRM F-2966
CESAR R. VALLENILLA
TX 83559
CV LFAG
100% DESIGN SUBMITTAL
M
AK
AL
AP
A, H
AW
AI
I
AS NOTED
A/E INFO
SEAL
GU
AM
Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813
A/E CONTRACT NO. N62478-20-D-5036
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
24 JUN 2024
N
AV
FA
C
P
AC
IF
IC
BC
1764210
AWK/DMK
KYM
JC
A/E Task Order No. N6274223F0324
FY
P R
O
JE
C T
G D
S C
O M
M
AN
D C
EN
TE
R
AN
DE
RS
EN
A
IR
F
OR
CE
B
AS
E
6/
/2
7:
:3
PM
C :\U se rs
\ra jb ah c\
D oc um en ts \P
3_
6-
AC
-S -3
D _C hr is tin a.
Ill ip ar am bi l.r vt
14AC-SF121
AC
-S F1
AC
CE
SS
C O
NT
RO
L
- R O O F
FR
AM
IN
G P
LA
N
14CC-A-101
SITE #
BUILDING ID DISCIPLINE
CONSECUTIVE NUMBERS
SITE #
SITE 01
SITE 02
SITE 14
BUILDING ID
AC - ACCESS CONTROL POINT
CC - COMMAND CENTER
FP - FIRE PUMP BUILDING
GI - GENERAL
PP - POWER PLANT
SF - SECURITY FORCE
ST - SITE
1/4" = 1'-0" 0 4' 8' 12'2'
GENERAL SHEET NOTES
GRAPHIC SCALE(S)
SHEET KEYNOTES
SHEET NAMING CONVENTIONSHEET NAMING CONVENTION
SCALE 1/4" = 1'-0"A2 FRAMING PLAN - ROOF
21 PRECAST CONCRETE GUTTER
22 8" NORMAL WEIGHT CONCRETE SLAB REINFORCED WITH
#4 @ 12" OC, CENTER ON SLAB EACH WAY AT MID-DEPTH
23 24"X32" BEAMS
PLAN
NORTH
A. FINISH GRADE OF 100'-0" CORRESPONDS TO A CIVIL
REFERENCE DATUM OF 521.45
B. REFER TO SHEETS 14AC-S-001 THRU 14AC-S-002 FOR
STRUCTURAL GENERAL NOTES.
C. REFER TO SHEETS 14AC-S-501 FOR TYPICAL CONCRETE
DETAILS.
D. REFER TO SHEET 14AC-S-001 FOR MATERIAL LEGENDS
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
G U
A M
P R
O J E
C T
S
IT
E
M
M A
N D
C E
N T
FINISH GRADE
100' - 0"
T/ROOF HIGH
111' - 9"
T/ROOF LOW
110' - 7"
SLOPE
RE: PLAN13'-0"RE: PLAN
29'-0"
PAVEMENT
RE: CIVIL
TURNSTILES
RE: CIVIL
FINISH GRADE
100' - 0"
AB
RE: PLAN 28'-0" RE: PLAN
30'-0"
T/ROOF
VARIES
PAVEMENT
RE: CIVIL
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
FOR REVIEW
ONLY
N
AV
FA
C
P
AC
IF
IC
Name
Registration Number #
These documents are for Design Review and not intended for
Construction Bidding or Permit Purposes. They were prepared by, or under the supervision of:
Date
TEXAS REGISTERED ENGINEERING FIRM F-2966
CESAR R. VALLENILLA
TX 83559
CV LFAG
100% DESIGN SUBMITTAL
M
AK
AL
AP
A, H
AW
AI
I
AS NOTED
A/E INFO
SEAL
GU
AM
Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813
A/E CONTRACT NO. N62478-20-D-5036
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
24 JUN 2024
N
AV
FA
C
P
AC
IF
IC
BC
1764210
AWK/DMK
KYM
JC
A/E Task Order No. N6274223F0324
FY
P R
O
JE
C T
G D
S C
O M
M
AN
D C
EN
TE
R
AN
DE
RS
EN
A
IR
F
OR
CE
B
AS
E
6/
/2
7:
:3
PM
C :\U se rs
\ra jb ah c\
D oc um en ts \P
3_
6-
AC
-S -3
D _C hr is tin a.
Ill ip ar am bi l.r vt
14AC-S-201
AC
-S -2
AC
CE
SS
C O
NT
RO
L
- F
RA
M
IN
G E
LE
VA
TI
O
NS
SCALE 1/4" = 1'-0"C1 BUILDING SECTION
SCALE 1/4" = 1'-0"C3 BUILDING SECTION
14CC-A-101
SITE #
BUILDING ID DISCIPLINE
CONSECUTIVE NUMBERS
SITE #
SITE 01
SITE 02
SITE 14
BUILDING ID
AC - ACCESS CONTROL POINT
CC - COMMAND CENTER
FP - FIRE PUMP BUILDING
GI - GENERAL
PP - POWER PLANT
SF - SECURITY FORCE
ST - SITE
1/4" = 1'-0" 0 4' 8' 12'2'
GRAPHIC SCALE(S)
SHEET NAMING CONVENTIONSHEET NAMING CONVENTION
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
G U
A M
P R
O J E
C T
S
IT
E
M
M A
N D
C E
N T
1'-6" 5'-6" 6'-6" 5'-6" 1'-6"
C3
14AC-S-401
20'-6"
'-6
B1
14AC-S-402
B3
14AC-S-401
TYP
SL
O
PE
SL
O
PE
T/SLAB
100'-0"
T/SLAB
100'-0"
T/SLAB
99'-8"
T/SLAB
99'-8"
C3
14AC-S-401
B3
14AC-S-401
20'-6"
1'-6"4'-0"1'-6" 1'-6"4'-0"1'-6"
1' -6
4'
-0
2' -6
20'-6"
1'-6" 8'-0" 1'-6" 8'-0" 1'-6"
1' -6
4'
-0
1' -6
B3
14AC-S-401
C3
14AC-S-401
C3
14AC-S-401
B3
14AC-S-401
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
FOR REVIEW
ONLY
N
AV
FA
C
P
AC
IF
IC
Name
Registration Number #
These documents are for Design Review and not intended for
Construction Bidding or Permit Purposes. They were prepared by, or under the supervision of:
Date
TEXAS REGISTERED ENGINEERING FIRM F-2966
CESAR R. VALLENILLA
TX 83559
CV LFAG
100% DESIGN SUBMITTAL
M
AK
AL
AP
A, H
AW
AI
I
AS NOTED
A/E INFO
SEAL
GU
AM
Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813
A/E CONTRACT NO. N62478-20-D-5036
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
24 JUN 2024
N
AV
FA
C
P
AC
IF
IC
BC
1764210
AWK/DMK
KYM
JC
A/E Task Order No. N6274223F0324
FY
P R
O
JE
C T
G D
S C
O M
M
AN
D C
EN
TE
R
AN
DE
RS
EN
A
IR
F
OR
CE
B
AS
E
6/
/2
7:
:3
PM
C :\U se rs
\ra jb ah c\
D oc um en ts \P
3_
6-
AC
-S -3
D _C hr is tin a.
Ill ip ar am bi l.r vt
14AC-S-401
AC
-S -4
AC
CE
SS
C O
NT
RO
L
- E
LE
CT
RI
CA
L
YA
RD
PL
AN
S
AN
D
EL
EV
AT
IO
NS
14CC-A-101
SITE #
BUILDING ID DISCIPLINE
CONSECUTIVE NUMBERS
SITE #
SITE 01
SITE 02
SITE 14
BUILDING ID
AC - ACCESS CONTROL POINT
CC - COMMAND CENTER
FP - FIRE PUMP BUILDING
GI - GENERAL
PP - POWER PLANT
SF - SECURITY FORCE
ST - SITE
1/4" = 1'-0" 0 4' 8' 12'2'
GENERAL SHEET NOTES
GRAPHIC SCALE(S)
SHEET KEYNOTES
SHEET NAMING CONVENTIONSHEET NAMING CONVENTION
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
SCALE 1/4" = 1'-0"B1 ELECTRICAL YARD - FOUNDATION PLAN
SCALE 1/4" = 1'-0"C3 ELECTRICAL YARD - ELEVATION
SCALE 1/4" = 1'-0"B3 ELECTRICAL YARD - ELEVATION
SCALE 1/4" = 1'-0"A1 ELECTRICAL YARD - FRAMING PLAN
04 18"X18" CONCRETE COLUMN
05 18"X18" CONCRETE BEAM
06 HOUSEKEEPING PAD RE: B2/14AC-S-402
07 6" THICK CONCRETE SLAB ON GRADE REINFORCED WITH
#4 @12" ON CENTER EACH WAY AT TOP OF SLAB
A. FINISH GRADE OF 100'-0" CORRESPONDS TO A CIVIL
REFERENCE DATUM OF 521.45
B. REFER TO SHEETS 14AC-S-001 THRU 14AC-S-002 FOR
STRUCTURAL GENERAL NOTES.
C. REFER TO SHEETS 14AC-S-501 FOR TYPICAL CONCRETE
DETAILS.
D. REFER TO SHEET 14AC-S-001 FOR MATERIAL LEGENDS
G U
A M
P R
O J E
C T
S
IT
E
M
M A
N D
C E
N T
SLOPE
SLOPE
CONCRETE SLAB
ELEVATION (VARIES)
RE: PLAN
1/2" JOINT w/ FILLER AND SEALANT
CMU BREEZE BLOCK
REFER TO ARCH
CONCRETE COLUMN
BEYOND
(4) #7 TOP
AND BOTTOM
#4 BEAM HOOP
STIRRUPS
CONC BEAM
PREPARED SUBGRADE
REFER TO S-002-FOUNDATION NOTES
FOR ADDITIONAL INFORMATION 4'-0"�
3" TYP
FOOTING
RE: PLAN
#5 @ 10" OC EACH FACE
#4 U-BARS @ 10" OC
WITH STD HOOKS
SLOPE 1/8" PER
FOOT MIN
SLOPE 1/8" PER FOOT MIN
CONCRETE KEY, TYP
1'-6"
TYP
2 1/2"
GRADE
RE: CIVIL
T/CONC
ELEV: 107'-0"
T/WALL
ELEV: 101'-6"
T/FOOTING
PER PLAN
1'
6"
2' -0
EQ 1'-4" EQ
4 #6, EA FACE
#4 @ 12", OC
EA FACE
5 #6 CONT, T&B
#4 @ 12" OC, T&B
FOOTING
RE: PLAN
TYP
3"
CONCRETE SLAB
DOWEL TO MATCH
SLAB REINFORCEMENT
SIZE AND LOCATION
PAVEMENT
RE: CIVIL
PREPARED SUBGRADE
REFER TO 14AC-S-002-
FOUNDATION NOTES FOR
ADDITIONAL INFORMATION
(2) #4 BARS
Ld
�12"
6"
1/2" JOINT w/ FILLER
AND SEALANT
4'-0"�
2' -0
CONCRETE COLUMN
T/CONCRETE
CMU BREEZE
BLOCK
EACH END
2"
TYP
2"
SPA=
CONCRETE BEAM
SPA= 3"
TYP
TYP EACH END
#3 HOOP STIRRUPS
(T
YP
LA
P
SP
LI
C E
C
LA
SS
B
2"
SP
A=
TY
P)
TY
P
EA
C
H E
N D
#5 HOOP TIES
& CROSS TIES
COL VERTICAL REINF
T/CONCRETE
CMU BREEZE BLOCK
WHERE REQUIRED
CONCRETE BEAM
BEAM HOOP STIRRUPS
CONCRETE COLUMN,
FOR BASE CONNECTION
TO FOUNDATION
COL VERTICAL REINF
COL TIE REINF
#4 @ 12" DOWELS
DRILLED AND SET
IN EPOXY
ROUGHEN SURFACE AND APPLY
A BONDING AGENT PRIOR TO
PLACING PAD
12"
24"
24"
#4 CONT AT PERIMETER
w/ #4 AT EACH CORNER
#4 @ 12"
EW
3/4" CHAMFER
EXIST CONCRETE
SLAB
NOTES:
1. CONFIRM REQUIRED SIZE AND
LOCATION OF ALL HOUSEKEEPING
PADS WITH EQUIPMENT
MANUFACTURER'S PRIOR TO
PLACEMENT OF CONCRETE. PROVIDE
PADS AS REQUIRED, WHETHER
SHOWN ON STRUCTURAL DRAWINGS
OR NOT.
2. WHERE REQUIRED, COORDINATE
HOUSEKEEPING PAD WITH ARCH AND
ELECTRICAL SO PENETRATIONS ARE
PLACED BEFORE CONCRETE IS
POURED.
3. CONTRACTOR MUST LOCATE EXISTING
SLAB REINFORCEMENT/TENDONS
PRIOR TO DRILLING SO ANY CONFLICT
CAN BE AVOIDED.
4. VERIFY HOUSEKEEPING PAD MINIMUM
THICKNESS WITH ELECTRICAL
DRAWINGS.
DOWELS
3" TYP @
3"
N O
TE
S
1&
6" M
IN
, R
E:
1/
2" C
LR
C
O
VE
R
6" 6"
(RE: ELECTRICAL DWGS)
EQUIPMENT
(TYP UON)
1' - 6"
(T
YP
U O
N
1'
6"
TYP
2 1/2"
#4 HOOP TIES &
CROSS TIES
(8) #8 BARS
CMU BREEZE BLOCK
RE: ARCHITECT
DRAWINGS
1/2" JOINT BETWEEN
CMU AND CONCRETE
COLUMNS, FILL WITH
SEALANT (TYP)
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
FOR REVIEW
ONLY
N
AV
FA
C
P
AC
IF
IC
Name
Registration Number #
These documents are for Design Review and not intended for
Construction Bidding or Permit Purposes. They were prepared by, or under the supervision of:
Date
TEXAS REGISTERED ENGINEERING FIRM F-2966
CESAR R. VALLENILLA
TX 83559
CV LFAG
100% DESIGN SUBMITTAL
M
AK
AL
AP
A, H
AW
AI
I
AS NOTED
A/E INFO
SEAL
GU
AM
Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813
A/E CONTRACT NO. N62478-20-D-5036
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
24 JUN 2024
N
AV
FA
C
P
AC
IF
IC
BC
1764210
AWK/DMK
KYM
JC
A/E Task Order No. N6274223F0324
FY
P R
O
JE
C T
G D
S C
O M
M
AN
D C
EN
TE
R
AN
DE
RS
EN
A
IR
F
OR
CE
B
AS
E
6/
/2
7:
:3
PM
C :\U se rs
\ra jb ah c\
D oc um en ts \P
3_
6-
AC
-S -3
D _C hr is tin a.
Ill ip ar am bi l.r vt
14AC-S-402
AC
-S -4
AC
CE
SS
C O
NT
RO
L
- E
LE
CT
RI
CA
L
YA
RD
- S
EC
TI
O
NS
A
ND
D
ET
AI
LS
14CC-A-101
SITE #
BUILDING ID DISCIPLINE
CONSECUTIVE NUMBERS
SITE #
SITE 01
SITE 02
SITE 14
BUILDING ID
AC - ACCESS CONTROL POINT
CC - COMMAND CENTER
FP - FIRE PUMP BUILDING
GI - GENERAL
PP - POWER PLANT
SF - SECURITY FORCE
ST - SITE
3/4" = 1'-0" 0 1' 2' 4'6"
1/4" = 1'-0" 0 4' 8' 12'2'
GRAPHIC SCALE(S)
SHEET NAMING CONVENTIONSHEET NAMING CONVENTION
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
SCALE 3/4" = 1'-0"B1 SECTION
SCALE 1" = 1'-0"C2 SECTION
SCALE 1" = 1'-0"A1 DETAIL
SCALE 1" = 1'-0"A2 DETAIL
SCALE NTSB2 SECTION AT ELECTRICAL EQUIPMENT HOUSEKEEPING PAD
SCALE 1" = 1'-0"A4
CONCRETE COLUMN AT
EQUIPMENT YARD DETAIL
G U
A M
P R
O J E
C T
S
IT
E
M
M A
N D
C E
N T
# 5 15 15 14 13
# 10 43 # 11 51
# 6
# 8 # 9
# 7 f'c=5000 psif'c=4000 psi Ldh
# 4 # 3
Ldh Ldh f'c=4500 psi Ldh f'c≥6000 psi
'Ldh' TENSION DEVELOPMENT
(EMBEDMENT) LENGTH FOR STANDARD
END HOOKS (GRADE 60 BARS - NORMAL
WEIGHT CONCRETE - GENERAL USE)
BAR
SIZE
STANDARD 90 HOOK
SIDE COVER > 2 1/2"
STANDARD 180 HOOK
SIDE COVER > 2 1/2"
Ldh
COVER
3" MIN Ldh
COVER
3" MIN
NOTES:
1. DEVELOPMENT LENGTH IS MEASURED FROM THE CONCRETE
JOINT TO THE FACE OF THE HOOK NEAREST THE JOINT.
2. MINIMUM REINFORCING SPACING IS 6 DIAMETERS ON CENTER
FOR DEVELOPMENT LENGTHS SHOWN. IF REINFORCING SPACING
IS AT LEAST 3 BAR DIAMETERS AND LESS THAN 6 BAR DIAMETERS
ON CENTER, INCREASE DEVELOPMENT LENGTH BY 60 PERCENT.
HOOK REINFORCING MUST NOT BE USED WHERE
SPACING IS LESS THAN 3 BAR DIAMETERS ON CENTER.
3. MINIMUM REINFORCING SIDE COVER TO BAR IS 2 1/2 BAR
DIAMETERS IF DEVELOPMENT LENGTH IS WITHIN THE CONFINED
CORE OF A COLUMN, OR 6 BAR DIAMETERS ELSEWHERE.
OTHERWISE, INCREASE DEVELOPMENT LENGTH BY 25 PERCENT.
SIDE COVER MUST IN NO CASE BE LESS THAN 2 BAR DIAMETERS.
4. VALUES MUST BE USED UNLESS NOTES OTHERWISE ON
DRAWINGS.
NOTES:
1. < MEANS LESS THAN,
≤ MEANS LESS THAN OR EQUAL TO,
> MEANS GREATER THAN.
# 4
# 6
# 5
2≤s<4 4≤s<6
6≤s 2≤s<4 4≤s<6
6≤s 2≤s<4 4≤s<6
6≤s 2≤s<4 4≤s<6
6≤s
# 11
# 7
# 8
# 9
# 10
2≤s<4 4≤s<6
6≤s 2≤s<4 4≤s<6
6≤s 2≤s<4 4≤s<6
6≤s 2≤s<4 4≤s<6
6≤s
# 3 2≤s<4 4≤s<6
6≤s
TENSION BAR DEVELOPMENT LENGTH (L ) --
REINFORCING STEEL STRENGTH, F = 60 ksi (1,2,3)
BAR
SIZE f' (psi)C-C
SPACING
(in) 4000 5000 6000 8000
ᵈ ʸ
12 12 12 12 12 12 12 12 12 12 12 12 19 17 16 14 15 14 13 12
29 26 24 21 19 17 16 14
42 38 34 30 23 20 19 16
71 64 58 51 36 32 29 26 33 29 27 23 93 83 76 66 47 42 38 33 37 34 31 27
118 106 97 84 59 53 49 42 46 42 38 33
150 134 122 106 75 67 61 53 57 51 47 41
184 165 151 131 92 83 76 66 68 61 56 49
15 14 13 12
19 17 16 14
23 20 19 16
ᶜ
NOTES:
1. < MEANS LESS THAN,
≤ MEANS LESS THAN OR EQUAL TO,
> MEANS GREATER THAN.
LAP SPLICE LENGTH (L ) --
REINFORCING STEEL STRENGTH, F =60ksi (1,2,4,5,6,7))
# 4
# 6
# 5
2≤s<4 4≤s<6
6≤s 2≤s<4 4≤s<6
6≤s 2≤s<4 4≤s<6
6≤s 2≤s<4 4≤s<6
6≤s
# 11
# 7
# 8
# 9
# 10
2≤s<4 4≤s<6
6≤s 2≤s<4 4≤s<6
6≤s 2≤s<4 4≤s<6
6≤s 2≤s<4 4≤s<6
6≤s
# 3 2≤s<4 4≤s<6
6≤s
BAR
SIZE
f' = 5000 psiC-C (8)
SPACING
(in) 0.75 1.5 2 2.5
ʸ
13 13 13 13
83 83 83 83 70 43 42 42 70 43 38 38
87 54 54 54 87 54 44 44
105 69 69 69 105 67 54 49 174 174 174 174 126 87 87 87 126 82 66 58 214 214 214 214 147 107 107 107 147 97 80 72
COVER (in) ᶜ
ˢᵗ
13 13 13 13 13 13 13 13 13 13 22 22 22 22 22
18 18 18 18 18 18 18 18
22222222 22 22 22 22
34 34 34 34 34 49 49 49 49 49
26 26 26 26 26262626
137 137 137 137
108 108 108 108
CONCRETE BEAM SCHEDULE
MARK
B1
DEPTH WIDTH LONGITUDINAL
REINFORCING
REMARKS
B2 B3
B4
STIRRUPS
2'-8" 2'-0" (5) #7, TOP & BOTTOM #4 @ 10" OC
#4 @ 10" OC
(4) #4 @ 6" OC AT EACH
END, REM. @ 10" OC
(5) #7, TOP & BOTTOM
(5) #7, TOP & BOTTOM
(5) #7, TOP & BOTTOM
(2) #5 SIDE BARS, ON EACH SIDE
(2) #5 SIDE BARS, ON EACH SIDE
(2) #5 SIDE BARS, ON EACH SIDE2'-0"
2'-0"
2'-0"
2'-8" 2'-8"
2'-8"
(2) #5 SIDE BARS, ON EACH SIDE
ADDITIONAL (3) #7 TOP BARS, AT EACH END
B5 (5) #7, TOP & BOTTOM (2) #5 SIDE BARS, ON EACH SIDE2'-0" #4 @ 10" OC2'-8"
(4) #4 @ 6" OC AT EACH
END, REM. @ 10" OC
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
FOR REVIEW
ONLY
N
AV
FA
C
P
AC
IF
IC
Name
Registration Number #
These documents are for Design Review and not intended for
Construction Bidding or Permit Purposes. They were prepared by, or under the supervision of:
Date
TEXAS REGISTERED ENGINEERING FIRM F-2966
CESAR R. VALLENILLA
TX 83559
CV LFAG
100% DESIGN SUBMITTAL
M
AK
AL
AP
A, H
AW
AI
I
AS NOTED
A/E INFO
SEAL
GU
AM
Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813
A/E CONTRACT NO. N62478-20-D-5036
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
24 JUN 2024
N
AV
FA
C
P
AC
IF
IC
BC
1764210
AWK/DMK
KYM
JC
A/E Task Order No. N6274223F0324
FY
P R
O
JE
C T
G D
S C
O M
M
AN
D C
EN
TE
R
AN
DE
RS
EN
A
IR
F
OR
CE
B
AS
E
6/
/2
7:
:3
PM
C :\U se rs
\ra jb ah c\
D oc um en ts \P
3_
6-
AC
-S -3
D _C hr is tin a.
Ill ip ar am bi l.r vt
14AC-S-501
AC
-S -5
AC
CE
SS
C O
NT
RO
L
- C O
NC
RE
TE
S
CH
ED
UL
ES
SCALE NTSB4
TENSION DEVELOPMENT (EMBEDMENT)
LENGTH FOR STANDARD END HOOKS
SCALE NTSB1 TENSION DEVELOPMENT LENGTH
SCALE NTSB2 TENSION LAP SPLICES
SCALE NTSA1 CONCRETE BEAM SCHEDULE
14CC-A-101
SITE #
BUILDING ID DISCIPLINE
CONSECUTIVE NUMBERS
SITE #
SITE 01
SITE 02
SITE 14
BUILDING ID
AC - ACCESS CONTROL POINT
CC - COMMAND CENTER
FP - FIRE PUMP BUILDING
GI - GENERAL
PP - POWER PLANT
SF - SECURITY FORCE
ST - SITE
SHEET NAMING CONVENTIONSHEET NAMING CONVENTION
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
G U
A M
P R
O J E
C T
S
IT
E
M
M A
N D
C E
N T
CONCRETE COLUMN
RE: PLAN
DOWELS TO MATCH
VERT COLUMN REINF
PREPARED
SUBGRADE
CONCRETE FOOTING RE: PLAN
PAVING
RE: CIVIL
(8) #8 TOP AND BOTTOM
4" THICK LEAN CONCRETE
C
LA
SS
B
L
AP
S
PL
IC
E
T/FTG EL:
RE: PLAN
B2
14AC-S-512
TYP
6"
R E:
P
LA
N
PL
AN
R E:
RE: PLAN
#8 @ 12" OC TOP
AND BOTTOM
3" SP
AC
IN
G
6" O
C3" (3) #4 TIES SET
IN FOOTING
90° BEND
HOOK
Ld Ld
Ld Ld Ld
Ld
WALL REINF
RE: SCHED
Ld
Ld
WALL REINF
RE: SCHED
ALTERNATE BEND
Ld Ld
Ld
PLAN AT CORNER PLAN AT INTERSECTION
PLAN AT CORNER PLAN AT INTERSECTION
NOTE:
1. ALL CORNER BARS MUST MATCH SIZE AND SPACING OF HORIZONTAL WALL REINFORCEMENT.
/4
/2
11 1/4"
/4
10 3/4"
11 1/2"
10 3/4" 10 3/4"
/4
10 3/4" 10 3/4"
PRINCIPAL REINFORCING
TIE OR STIRRUP
90° HOOK
MAX OFFSET BEND
180° HOOK
DETAIL NOTES:
1. BENDS MUST BE MADE COLD.
NOTE:
FOR 'D' ETC REFER TO
CRSI HANDBOOK
GOVERNING EDITION.
#4 3" 3 3/4"#5
MIN
D
2 1/4"#3
BAR
DIA
#6 5 1/4"#7
#8 9 1/2"#9
#10 12"#11
4 1/2"
6"
10 3/4"
D D d d d
4db OR 2 1/2" MIN
3" MIN6d
O R
D
PAVING RE: CIVIL~
CONT TIE BEAM
RE: PLAN
RE: PLAN
(8) #4 @ 6" OC
AT EACH END,
REM. @ 8" OC
R E:
P
LA
N R
E:
P
LA
N
(4) #8 TOP
AND BOTTOM
(1) #4 EACH SIDE
T/PAVING EL
RE: CIVIL
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
FOR REVIEW
ONLY
N
AV
FA
C
P
AC
IF
IC
Name
Registration Number #
These documents are for Design Review and not intended for
Construction Bidding or Permit Purposes. They were prepared by, or under the supervision of:
Date
TEXAS REGISTERED ENGINEERING FIRM F-2966
CESAR R. VALLENILLA
TX 83559
CV LFAG
100% DESIGN SUBMITTAL
M
AK
AL
AP
A, H
AW
AI
I
AS NOTED
A/E INFO
SEAL
GU
AM
Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813
A/E CONTRACT NO. N62478-20-D-5036
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
24 JUN 2024
N
AV
FA
C
P
AC
IF
IC
BC
1764210
AWK/DMK
KYM
JC
A/E Task Order No. N6274223F0324
FY
P R
O
JE
C T
G D
S C
O M
M
AN
D C
EN
TE
R
AN
DE
RS
EN
A
IR
F
OR
CE
B
AS
E
6/
/2
7:
:4
PM
C :\U se rs
\ra jb ah c\
D oc um en ts \P
3_
6-
AC
-S -3
D _C hr is tin a.
Ill ip ar am bi l.r vt
14AC-S-502
AC
-S -5
AC
CE
SS
C O
NT
RO
L
- T
YP
IC
AL
C O
NC
RE
TE
D
ET
AI
LS
SCALE 3/4" = 1'-0"B2 SECTION
SCALE NTSC2 TYPICAL CORNER BAR PLACEMENT DETAIL
SCALE NTSC1 TYPICAL BAR BENDS
SCALE 3/4" = 1'-0"B1 TYPICAL TIE BEAM SECTION
14CC-A-101
SITE #
BUILDING ID DISCIPLINE
CONSECUTIVE NUMBERS
SITE #
SITE 01
SITE 02
SITE 14
BUILDING ID
AC - ACCESS CONTROL POINT
CC - COMMAND CENTER
FP - FIRE PUMP BUILDING
GI - GENERAL
PP - POWER PLANT
SF - SECURITY FORCE
ST - SITE
3/4" = 1'-0" 0 1' 2' 4'6"
GRAPHIC SCALE(S)
SHEET NAMING CONVENTIONSHEET NAMING CONVENTION
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
G U
A M
P R
O J E
C T
S
IT
E
M
M A
N D
C E
N T
CONCRETE SLAB
RE: PLAN
RE: SCHEDULE
WIDTH
ST…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .