ATTACHMENT_J_1_Work_Spec_MSCOK 27-002_N6264927RK002_0001.docx

DOCX document 66 KB Posted

Attached to
USNS YUKON (T-AO 202) Voyage Repair Availability KR
Solicitation number
N6264927RK002
Issued by

About this file

This is a Work Specification document for a Voyage Repair Availability project for USNS YUKON (T-AO 202), a naval oiler vessel. The specification MSCOK 27-002 outlines the repair requirements and technical parameters for the ship's maintenance during its voyage repair availability at Chinhae, South Korea. The work specification establishes the performance standards, technical requirements, and acceptance criteria that contractors must meet to complete the voyage repair availability in accordance with Navy standards and procedures. The document serves as the primary technical reference for defining the scope of work, material specifications, workmanship standards, and quality assurance requirements that bidders must use to develop their proposals and cost estimates for this Firm-Fixed-Price competitive solicitation issued by NAVSUP Fleet Logistics Center Yokosuka.

The contract opportunity is restricted to sources duly authorized to operate and do business in South Korea under DFARS requirements. Contractors must possess appropriate base access credentials for performance at the Chinhae installation, which is subject to U.S. Army installation security and access controls, and must demonstrate an executable operational plan for personnel access upon award. Timely performance is critical, with failure to meet delivery milestones potentially subjecting contractors to default remedies under FAR 52.249-8. Prospective offerors must be registered in SAM.gov to be eligible for award and should contact the points of contact identified in the RFP to request the detailed work specification via DoD Safe, including their UEI number with the request.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Print Date:

10/30/2026

MSC Corrective Maintenance

Engineering Report

USNS YUKON

(TAO 202)

MSCOK 27-002

2026-11-30 - VRA

WORK ITEM INDEX REPORT

Item Number
Title
Category
SECTION 0000
GENERAL SERVICES AND REQUIREMENTS
0001
INTENT AND GENERAL REQUIREMENTS
A
0013
PROJECT MANAGEMENT
A
0020
GAS FREE CERTIFICATES
A
SECTION 0100
HULL AND STRUCTURAL
0114
RENEW CONTAINMENT TUB DRAIN VALVES
A
SECTION 0500
AUXILIARY MACHINERY
0501
NR2 CT WINCH REPAIRS
A
0502
FABRICATE CFW AND JW STRAINER BASKETS
A
SECTION 0600
HABITABILITY OUTFITTING AND FURNISHINGS
0601
GALLEY REFRIGERATION SERVICE
A
0666
INSPECT, TEST AND CERTIFY MATERIAL HANDLING
A
SECTION 0800
HVAC
0801
TROUBLESHOOT AND REPAIR BRIDGE AC
A
0808
RECONDITION FANS AND MOTORS
A
SECTION 1000
UNDERWAY REPLENISHMENT EQUIPMENT
1002
CARGO BOOM GUIDE BUMPER REPLACEMENT
A
Page 1 of
1

image1.jpeg

File details come from the government source that posted it. Updated .