MSC Chem Treatment Handbook.pdf
PDF 2 MB Posted
- Attached to
- USNS SIOUX EMERGENCY DRYDOCK
- Solicitation number
- N40442-10-T-4027
About this file
ADDED ITEMS
View the file
Other files
Show 40 more
Latest 50 of 86 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MSC Shipboard
Chemical Treatment Handbook
N00033-02-D-8000
Drew Marine
MSC Shipboard Chemical Treatment Handbook
CHAPTER I
MSC Handbook Table of Contents
Chapter I. Program Overview Scope Procedures
• Ordering
• Foam Analysis
• Fuel Analysis MSC Survey Check List Service Report Forms
Chapter II. Points of Contact Drew Marine & MSC Chart
Chapter III. Product List Listing of all contract products Order Form
Chapter IV. Water Treatment Products Products lists and descriptions IV.A. Water Quality IV.B. Water Purification IV.C. Boiler Operations IV.D. Cooling Water Systems IV.E. Lay-Up Procedures IV.F. Analysis IV.G. Record Keeping
Chapter V. Fuel Treatments and Testing V.1. Fuel Oil Biocide V.2. Fuel Oil Conditioner V.3. Combustion Deposit Modifier V.4. Soot Combustion Catalyst V.5. Fuel Oil Testing Program V.6. Bacteria Detection V.7. Tank Thief Sounding Tube Samplers
Chapter VI. General Cleaners and Descalers VI.1. ACC/METM Air Cooler Cleaner VI.2. AMEROID® DC Disc Cleaner VI.3. AMEROID OSC One Step Cleaner VI.4. AMEROID RSR Rust Stain Remover VI.5. Citric Acid Cleaner VI.6.A. DREW ELECTRICTM 2000 Motor and Parts Cleaner VI.6.B. DREW ELECTRIC Fast Dry Motor and Parts Cleaner VI.7. DREWCLEAN® 2000 Quick Breaking Degreaser VI.8. ENVIROMATE® 2000 General Purpose Cleaner VI.9. Flight Deck Cleaner – EDGE® Heavy Duty Cleaner VI.10. Navalkleen1 and Navalkleen II Biological Bilge Water Treatment VI.11. SAF-ACIDTM Descaling Compound VI.12. SNCTM 2000 Carbon Remover
Chapter VII. Potable Water Treatments VII.1. CILTM Corrosion Inhibitor VII.2. Everpure2 Bromine System Consumables VII.3. Drinking Water Test kit – HACH3 CEC-2 VII.4. Bacteria Test – Drew Microbiological Dual Assay Slide Kit
Chapter VIII. Sanitation Systems VIII.1. BIOTAL4 MDS 2000 Shipboard Waste Systems Treatment VIII.2. AMEROID® MSD-PAK Organic Waste Treatment VIII.3. Liquid Sodium Hypochlorite 15% VIII.4. DREWPLUS® L-474 Foam Control Agent
Chapter IX. Refrigerants IX.1. AMERFROSTTM A-22 Refrigerant IX.2. AMERFROST A-134a Refrigerant IX.3. AMERFROST A-404a Refrigerant
Chapter X. Equipment X.1. BWTTM Dosing System X.2. Drew SWTTM Dosing System X.3. Graymills5 Model PL 422 Portable Parts Cleaning System X.4. AMEROID Chemical Cleaning Circulating Unit
Chapter XI. Fire Fighting Foam Concentrates XI.1. National Foam Universal CG 6, Alcohol Resistant AFFF XI.2. National Foam Aer-O-Foam6 3% Regular Protein XI.3. National Foam Aer-O-Foam XL-3 Fluoroprotein Concentrate XI.4. Ansulite7 3 X 3 Low Viscosity ARC XI.5. National Foam Aer-O-Water6 3EM AFFF Foam Concentrate XI.6. National Foam Aer-O-Water 6EM AFFF Foam Concentrate
Chapter XII. Other Products XII.1. Cortec8 VCI 110 Emitter and VCI 238 Spray XII.2. PowerBack9 4074 Concentrated Cleaner
Chapter XIII. Test Procedures Summary XIII.A.1. Explanation of Test Rationale and Instruction Charts
Chapter XIV. Product Data Sheets & Material Safety Data Sheets
SCOPE OF THE PROGRAM
CONTRACT NO.: N00033-02-D-8000
CONTRACT: Military Sealift Command (Chemical Treatment Program)
CONTRACTOR/PROGRAM MANAGER: Ashland Specialty Chemical One Drew Plaza Boonton, NJ 07005
Program Manager shall:
♦ Prescribe and define a comprehensive shipboard chemical treatment program for monitoring and controlling critical equipment and systems aboard all MSC vessels.
♦ Provide all services, supplies, materials and resources and perform the necessary management, to support the implementation of the program aboard all MSC vessels.
♦ Respond timely to all requests for products and technical support services from all MSC authorized individuals throughout the world.
Contract Operator
Creates Email or Fax to MSCHQ Ordering Officer
Delivery Order is created and technically reviewed
Ordering Officer authorizes Delivery Order
Delivery Order Received by
Contractor via electronic mail
Contractor processes requirement to the ship
Ship recieves products or services
8/6/2002
Chemical Contract Ordering Procedures
Ship sends email confirming delivery or products and services
Program Office authorizes funds/ certified by N8
Delivery Order auto-created as a PO into FMS
Delivery Order entered into FMS as a requisition
N7 Receipts for products and services
NFAF Ships
Creates an email of fax to N7 West or East Odering
Officer
1. Refer To ABS Oil Testing
Services Manual For Instructions
2. Take Fuel Samples Only In
Approved Sample
Containers, 3 Per Bunkering
4. Fill Out and Affix Marine Fuel Sample Label On
Sample Bottle, One To Each
Bottle (Sect 11)
5. Place Each Bottle Into A
Separate Plastic Bag Provided.
6. Twist Top Of Bag and Snap On A Metal Seal Provided
7. Complete Bunker Data Form, Retain Yellow Copy
(Sect 6)
8. Place Sample Bottle And White Copy Of Bunker Data Form Into
Shipping Box And Seal With Tape
9. Consult Laboratory
Directory For Nearest
ABSOTS
Laboratory
(Sect 2)
10. Complete Proforma
Invoice (Sect 7) And DHL Shipment Airway Bill
(Sect 10) As Required
11. Choose Mailer Address
Label From Sect 12 Based Upon
Laboratory Directory (Sect 2)
12. Arrange With Agent To Send Samples
Ashore For Courier
Shipment To
ABSOTS
ABSOTS Fuel Oil Sample Shipping Procedures
3. Make Sure The Bottle Lid Is Tight And The Bottle Is Wiped
Off.
NOTE: RETAIN ONE SAMPLE ON BOARD SHIP,
GIVE ONE TO BUNKER SUPPLIER, SEND ONE TO
ABSOTS FOR ANALYSIS
NOTE: COLOR CODING OF SHIPPING LABEL IS
SAME AS COLOR OF DIRECTORY PAGE FOR
YOUR LOCATION
1. Purchase Foam Sample Kit From Drew
Marine
2. Circulate Fixed Foam Tank for 45 Minutes to
Insure Uniform Sample
3. Remove Sample Bottle From Foam Kit
- Read Instructions Concerning Labelling
4. Draw Sample Form Level
Gauge or Drain Line
5. Complete Sample Bottle
Label, with Tank Location, Date, Foam Type, Ship Name, etc.
6. Seal Sample Bottle per
Instructions
7. Affix Label to Sample
Bottle
8. Complete Request for
Analysis Form
9. Insert Bottle and Request for
Analysis Into Mailer
10. Affix Mailer Address Label
11. Express Mail Completed
Sample To Address on
Mailing Label
Foam Sampling Procedures
MSC SURVEY CHECK LIST
Background Yes No
• Contacted Chief Engineer and recorded name
• Provided On-Board Chemical Handbook
• Chemical order form is understood
• Provided MSDS Booklet/Disc
• Reviewed completed logs
• Provided complete set of logs for all treated systems
• Provided and updated chemical treatment program chart
• Met with all engineers to be trained and documented names
• Vessel Engineer concerns have been noted
Cooling water
• Confirmed proper treatment products
• Tested all cooling water systems
• Recorded make-up water quality
• Noted systems not treated
• Noted contaminated systems
• Noted turbid systems
• Reviewed bacteria test procedures
• Discussed biocide treatment In closed loop systems
• Cooling Water treatment logs are complete
Boiler water
• Proper treatment products are used and noted
• All boiler systems are tested
• Recorded deaerator pressure/temperature
• Recorded feedwater temperature
• Recorded make-up water quality
• Tested pH meter and Conductivity meter
• Proper idle boiler procedures are followed
• Proper boiler lay-up procedures are followed
• Boiler Water treatment logs are complete
Boiler Water Dosing Equipment
• Recorded installed dosing equipment
• Recorded treatment products injection location
• Reviewed proper dosing procedures
Evaporators
• AMEROYAL® treatment is properly dosed
• SAF-ACIDTM antiscalant as used properly when required
• Actual capacity and rated capacity are noted
• Distillate logs are complete
Fuel storage
• AMERSTAT® 25 bacteria controller is used and dosed properly
• Fuel Treatment logs are complete
Seawater Dispersant
• DREWSPERSE® SWD antifoulant is properly dosed
• Seawater pump capacities are noted
• SWD Logs are complete
Sanitary System and Treatment Plant
• Sewage system capacity recorded
• AMEROID® MSD-PAK treatment is dosed properly
• BIOTAL4 MDS 2000 is used by Steward’s Dept
Engine Room Maintenance
• ENVIROMATE® 2000 is used for general cleaning
• DREWCLEAN® 2000 is the degreaser and bilge cleaner
• DREW ELECTRICTM 2000 is the motor and parts cleaner
• ACC/ME® is used in-service
• AMEROID® DC is used for Purifier cleaning
• SNCTM 2000 is the carbon tip cleaner
• Oily Water Separator data is noted and equipment is functional
• Air Cooler cleaning frequency is noted
• Purifier data is noted and cleaning frequency is documented
• Electrical boxes include VCI protection
Potable Water Treatment
• Using brominator
• Sufficient cartridges on board for maximum 6 months
Refrigerant Products
• Using 60 liter cylinders
• Using other sizes
• Sufficient inventory on board for 6 months usage
Deck Department
• Chief Officer has been contacted and name documented
• Product manual has been provided
• Potable Water test kit CEC-2 on board
• MSDS Booklet/Disc has been provided
• Note other chemical or cleaning requirements
Fire Fighting Foam
• Main foam tanks full
• Back-up inventory of drums on board
• Portable pails on board
• Due for sampling
• Update foam survey with any changes
Inventory
• Chemical Inventory is sufficient for six months
• All treatment program test kits are complete for six months
• Product stowage is secure
• Product expiration dates have been checked
Manuals and Literature
• Vessel Product list has been reviewed and is current
• On Board chemical handbook is current
• MSDS Booklet/Disc is updated
• Order forms are available
• Chemical treatment program chart is complete
STANDARD SERVICE REPORT – MEDIUM PRESSURE BOILERS W/COOLING SYSTEMS
Comments must be provided for all negative answers.
VESSEL : FLAG :
FORMER VESSEL NAME (IF APPLICABLE) : RON No. :
COMPANY : WK No. :
SERVICE LOCATION : VESSEL No. :
ENGINEER CONTACTED : DATE :
ARE LOGS SENT TO: HOME OFFICE: YES NO DREW: YES NO
MAIN ENGINE MFG: Generators:
PRODUCT IN USE:
DEWT-NC 3,000 - 4,500 ppm LIQUIDEWT 10,000 - 15,000 ppm MAXIGARD 19,000 - 42,000 ppm OTHER
IS DISTILLED WATER USED FOR MAKE-UP? : YES NO
IF NO, STATE MAKE-UP WATER HARDNESS & CHLORIDES
Systems HT or Jacket LT or CFW Fuel v/v Piston Aux Eng. 1 Aux Eng. 2
CAP (tons) Treatment Levels
Chlorides
ACC-9 USED YES NO ACC/ME USED YES NO
IN SERVICE YES NO OUT OF SERVICE YES NO
FREQUENCY MANOMETER USED YES NO
BOILER / EGE MFG :
DRUM PRESSURE: WATER CAPACITY:
PRODUCT IN USE: ADJ-B GC DREWPLEX OX SLCC-A
CONTINUOUS DOSING? YES NO
INJECTION POINT CORRECT? YES NO
DREWPLEX OX SAMPLING POINT CORRECT? YES NO
IS DISTILLED WATER USED FOR MAKE UP? YES NO
IF NO: MAKE UP WATER CHLORIDES MAKE UP WATER CONDUCTIVITY
TESTS Phosphate P-Alkalinity T-Alkalinity Chloride DREWPLEX
OX
pH Conductivity
Control Limits 20 - 40 ppm 100 – 150 ppm Less than 2 x Max 300 ppm .4 - .8 ppm 1-2 Drops H2SO4 < 700 µmhos
Boiler: ppm ppm ppm ppm µmhos
Boiler: ppm ppm ppm ppm µmhos
Boiler: ppm ppm ppm ppm µmhos
Condensate ppm Drop(s) µmhos
Feed-water ppm Ppm Drop(s) µmhos
COMMENTS AND RECOMMENDATIONS:
DREW SERVICE ENGINEER
STANDARD SERVICE REPORT – LOW-PRESSURE BOILERS W/COOLING SYSTEMS
VESSEL : FLAG :
FORMER VESSEL NAME (IF APPLICABLE) : RON No. :
COMPANY : WK No. :
SERVICE LOCATION : VESSEL No. :
ENGINEER CONTACTED : DATE :
ARE LOGS SENT TO: HOME OFFICE: YES NO DREW: YES NO
MAIN ENGINE MFG: Generators:
PRODUCT IN USE:
DEWT-NC 3,000 - 4,500 ppm LIQUIDEWT 10,000 - 15,000 ppm MAXIGARD 19,000 - 42,000 ppm OTHER
IS DISTILLED WATER USED FOR MAKE-UP? : YES NO
IF NO, STATE MAKE-UP WATER HARDNESS & CHLORIDES
Systems HT or Jacket LT or CFW Fuel v/v Piston Aux Eng. 1 Aux Eng. 2
CAP (tons)
Treatment Levels
Chlorides
ACC-9 USED YES NO ACC/ME USED YES NO
IN SERVICE YES NO OUT OF SERVICE YES NO
FREQUENCY MANOMETER USED YES NO
BOILER / EGE MFG :
DRUM PRESSURE: WATER CAPACITY:
PRODUCT IN USE: AGK-100 AMERZINE DREWPLEX AT DREWPLEX OX
CONTINUOUS DOSING? YES NO
INJECTION POINT CORRECT? YES NO
DREWPLEX OX SAMPLING POINT CORRECT? YES NO
IS DISTILLED WATER USED FOR MAKE-UP? YES NO
IF NO: MAKE UP WATER CHLORIDES: MAKE UP WATER CONDUCTIVITY:
TESTS Phosphate Hydrate
Alk li i DEHA Hydrazine pH Conductivity Chlorides
Control Limits 10 - 20 ppm 40 – 65 ppm .4 – .8 ppm 0.03 - 0.1 1-2 Drops H2SO4 < 700 µmhos Max 300 ppm
Boiler: ppm ppm ppm µmhos ppm
Boiler: ppm ppm ppm µmhos ppm
Boiler: ppm ppm ppm µmhos ppm
Condensate Drop(s) µmhos ppm
Feed-water ppm Drop(s) µmhos ppm
COMMENTS AND RECOMMENDATIONS:
DREW SERVICE ENGINEER
STANDARD SERVICE REPORT – HIGH-PRESSURE BOILERS
VESSEL: FLAG:
COMPANY: VESSEL No.
SERVICE LOCATION: RON No.
ENGINEER CONTACTED: DATE:
LOG REVIEW:
BOILER MFG : CAPACITY M3 DISTILLED MAKE-UP YES NO
DRUM PRESSURE: Kg/CM2 CONTINUOUS DOSING YES NO
INJECTION POINT:
TESTS P-ALK T-ALK PHOS-
PHATE
CHLORIDES HYDRAZINE DEHA pH CONDUCT-
IVITY
SILICA
PORT BOILER
STBD BOILER
COMMENTS:
DREW REPRESENTATIVE TESTING ENGINEER
CHIEF ENGINEER
CHAPTER II
Worldwide Chemical Contract Organization
Susan Paolini Contracting Officer
(202) 685-5933 susanpaolini@msc.navy.mil
Mike Sullivan N7 West Ordering Officer
(619) 524-9689 msullivan@msc.navy.mil
Rene Fry Contracting Officer’s
Representative
(202) 685-5736
Al Garland N7 East Ordering Officer
(757) 417-4435 alan.garland@msc.navy.mil
Gwen Haynes Logistics Manager
(619) 524-9685 gwendolyn.haynes@msc.navy.mi
Sean Goodwin Logistics Manager
(202) 685-5732 sean.goodwin@msc.navy.mil
Mike Polak Technical Assistant
(757) 417-4448 mike.polak@msc.navy.mil
Ron Ieva Sales Director U.S. and Canada
(973) 263-4168 raieva@ashland.com
John Wolf Technical Manager
(973) 263-7713 jwolf@ashland.com
Patrick Lynch Contract Manager West
(973) 263-7442 pflynch@ashland.com
Kevin Gilbert Account Manager
(757) 853-1986 kagilbert@ashland.com
Melissa Miller Contract Administrator
(973) 263-7469 mmiller@ashland.com
Military Sealift Command
Ashland Specialty Chemical Company
After Hours Orders – 1-800-526-1015 Spill/Emergency – 1-800-ASHLAND Outside U.S. – 1-606-324-1133 In Europe: 49-621-604-3333 (BASF Hot Line)
PROCEDURES FOR PROVIDING FEEDBACK
1. Feedback, comments, recommendations, or requests for amplification of items covered under the contract and / or covered by this manual should be sent to the MSCHQ point of contact.
Because Drew Marine’s services are specified by a contract, no request can be made directly to Drew Marine except through the Contracting Officer or his designated representative, who will know what services are covered under the contract.
2. Feedback on logs and service should be expedited. Telephonic inquiries to the appropriate point of contact listed in section 1 B are the normal feedback means. E-mail messages and FAXES are also appropriate means of feedback.
3. The normal feedback loop will be through the Drew Marine Service Engineer during a six-month periodic service call.
a. The field service engineer is required to fill out a Drew Marine Service Report Form (MSR1) during the call to provide a permanent record of the service call results. The MSR1 specifically covers topics such as testing all systems, condition of chemicals and reagents onboard, training and delivery services.
b. Once completed, the MSR1 is forwarded electronically to the Drew U.S. Marine Division
Tehcnical Manager. After review of and concurrence with the information contained on the form, the Technical Manager then e-mails the form to MSCHQ for review. All comments are considered for incorporation into the MSC chemical treatment programs.
Commments are then e-mailed to the Area Commands / Port Engineers in-charge of the vessel for review. A copy of the commented MSR1 is e-mailed to the appropriate vessel’s Chief Engineer.
MSR1
ON-SITE
FEEDBACK TO SHIP
c. Using this method, a ship service call eventually runs full circle, with an electronic record, to ensure the call was made and the objectives were met. Drew Marine has been using this system of service call reporting quite successfully for a number of years.
4. Maintenance problems requiring industrial assistance identified through onboard testing should be passed to the ship’s Port Engineer through normal channels.
SHIP’S CHIEF
ENGINEER
DREW
TECHNICAL
MANAGER
MSC
HEADQUARTERS
AREA
COMMAND
PORT
ENGINEER DREW FIELD
SERVICE
ENGR
(ONBOARD)
CHAPTER III
PRODUCTS LIST
CATEGORY GENERIC NAME PRODUCT NAME Units Boiler Water Treatment Phosphate ADJUNCT B KG Boiler Water Treatment LP Boiler Water Conditioner DREWPLEX AT KG Boiler Water Treatments Oxygen Scavenger DREWPLEX OX LTR Boiler Water Treatment Alkalinity Control GC LTR Boiler Water Treatment Condensate Treatment SLCC-A LTR Cleaners & Descalers Air Cooler Cleaner ACC-ME LTR Cleaners & Descalers Purifier Disk Cleaner AMEROID DC LTR Cleaners & Descalers Diesel Cooling Sys In-line Cleaner AMEROID OSC LTR Cleaners & Descalers Motor Parts Cleaner DREW ELECTRIC 2000 LTR Cleaners & Descalers Engine Room Bilge Cleaner DREWCLEAN 2000 LTR Cleaners & Descalers Flight Deck Cleaner EDGE LTR Cleaners & Descalers General Cleaner ENVIROMATE 2000 LTR Cleaners & Descalers Range Hood Cleaner ENVIROMATE 2000 LTR Cleaners & Descalers Biological Bilge Water Treatment NAVALKLEEN LTR Cleaners & Descalers Gas Turbine Engine Cleaner POWERBACK 4074 LTR Cleaners & Descalers Rust Cleaner AMEROID RSR LTR Cleaners & Descalers Descaling Compound SAF-ACID KG Cleaners & Descalers Burner Tip Carbon Remover SNC 2000 LTR Cooling Water Treatment Cooling System Biocide (Closed
Loop)
BIOSPERSE 255
(CONUS+HI)
LTR
Cooling Water Treatment SW Cooling System Anti-Fouling Dispersant
DREWSPERSE SWD LTR
Cooling Water Treatment Diesel Engine Central Cooling LIQUIDEWT LTR Cooling Water Treatment Diesel Coolant Treatment MAXIGARD LTR Cooling Water Treatment SW Biological Test Kit MICROBIOLOGICAL
DUAL ASSAY SLIDES
EA
Cooling Water Treatment 6 month refill MICROBIOLOGICAL
DUAL ASSAY SLIDES
EA
Cooling Water Treatment Propylene Glycol PROPYLENE GLYCOL LTR Dosing & Cleaning Equipment ACC-9 Dosing Assembly ACC/ME DOSING UNIT
PM
EA
Dosing & Cleaning Equipment Low Pressure Boiler Dosing Unit BWT DOSING SYSTEM, 16 bar
EA
Dosing & Cleaning Equipment Evaporator Dosing Unit BWT DOSING SYSTEM, 16 bar
EA
Dosing & Cleaning Equipment Chemical Cleaning Circulation Unit CHEMICAL CLEANING
CIRCULATING UNIT
EA
Dosing & Cleaning Equipment DOSING EQUIPMENT DIAPHRAGM, PUMP 16 bar
EA
Dosing & Cleaning Equipment DOSING EQUIPMENT MEMBRANE, DOSING
PUMP MEDO 10FR
EA
Dosing & Cleaning Equipment DOSING EQUIPMENT PUMP SPARES KIT, NP 16 bar
EA
Dosing & Cleaning Equipment High Pressure Boiler Dosing Unit SERIES 200
CHEMICAL METERING
PUMP/TANK, Simplex
EA
Dosing & Cleaning Equipment High Pressure Boiler Dosing Unit SERIES 200
MAINTENANCE KIT
EA
Dosing & Cleaning Equipment High Pressure Boiler Dosing Unit SERIES 200
OVERHAUL KIT
EA
Dosing & Cleaning Equipment DOSING EQPT SPARES AIR
DIAPHRAGM PUMP
EA
Dosing & Cleaning Equipment DOSING EQPT SUCTION ASSY, DOSING PUMP MEDO
EA
Dosing & Cleaning Equipment Saltwater Programmable Dosing Unit
SWT-3 DOSING
SYSTEM
EA
Dosing & Cleaning Equipment Chemical Cleaning Tank TL 422 CHEMICAL
CLEANING TANK
EA
Evaporator Treatment Evaporator Feedwater Treatment AMEROYAL LTR Evaporator Treatment Citric Acid Cleaner CITRIC ACID
CLEANER
KG
Fire Fighting Foam 3% AFFF FOAM Aer-O-Water 3% AFFF pails Fire Fighting Foam 6% AFFF FOAM Aer-O-Water 6% AFFF Pails Fire Fighting Foam Low Viscosity 3% ARC FOAM Ansul Foam Ansulite
3X3 Low Viscosity
ARC
Drum
Fire Fighting Foam Foam Systems: Fixed and Portable Foam Systems: Fixed and Portable
EA
Fire Fighting Foam Foam Concentration Test Foam Test EA Fire Fighting Foam 3% Regular Protein FOAM National Foam 3%
Regular Protein Pail
Fire Fighting Foam Universal CG 6% FOAM National Foam Universal CG6
Drum
Fire Fighting Foam National Foam XL-3 3% Fluoroprotein
National Foam XL-3 3% Fluoroprotein
Drum
Fuel Testing Fuel Oil Sample Bottle & Mailers ABSOTS SAMPLE KIT EA Fuel Testing Fuel Oil Thief Sampler CONBAR BOMB GRAD
SAMPLER 1-1/8 X 15
EA
Fuel Testing Fuel Oil Testing (Distillate) Fuel Oil Test (Distillate) EA Fuel Testing Fuel Oil Testing (IFO) Fuel Oil Testing (IFO) EA Fuel Treatment Combustion Modifier AMERGIZE LTR Fuel Treatment Fuel Oil Treatment (Stabilizer) AMERGY 222 LTR Fuel Treatment Fuel Oil Biocide AMERSTAT 25 LTR Fuel Treatment Soot Combustion Catalyst SOOT STICKS KG Fuel Treatment FO Biological Test Kit SULFATE REDUCERS per test
EA
Potable Water Treatment Potable Water Treatment BROMINE CTDGE Potable Water Treatment Potable Water Test Kit CEC-2 TEST KIT 110
VOLT
EA
Potable Water Treatment Fresh Water System Corrosion Inhibitor.
CIL LTR
Potable Water Treatment 6 month refill COLIFORM MUG
SOLUTION - 15/PKG
EA
Potable Water Treatment 6 month refill COLIFORM SAMPLE
BAGS - 25/PKG
EA
Potable Water Treatment 6 month refill FREE CHLORINE PP EA Refrigerants Refrigerant 134a R-134A KG Refrigerants Refrigerant 22 R-22 KG
Sanitary System Treatment Sewage Vacuum System BIOTAL MDS 2000 LTR Sanitary System Treatment Sewage Treatment Defoaming
Agent
DREWPLUS L474 LTR
Sanitary System Treatment Type II MSD Sewage Treatment MSD-PAK KG Sanitary System Treatment Sewage Effluent Disinfectant SODIUM
HYPOCHLORITE
LTR
Services Chemical Analysis Chemical Analysis EA Services Emergency Service Call Emergency Service Call EA Services Engineering Support Engineering Support HR Services Initial Service Call Initial Service Call EA Services Periodic Service Call Periodic Service Call EA VCIs Vapor Corrosion Inhibitors CORTEC 110 EMITTER EA VCIs Vapor Corrosion Inhibitors CORTEC 238 SPRAY EA WT Test Kits Ammonia Test Kit AMMONIA AMPOULES EA WT Test Kits Conductivity Test Kits BASIC PORTABLE
CONDUCTIVITY KIT
WT Test Kits
TEST EQPT BOTTLE W/DROPPER
FOR PHTHALEIN RED
EA
WT Test Kits TEST EQPT BRASS SCOOP, 0.2 grams
EA
WT Test Kits HP Chloride 1 PPM test kit CHLORIDE HP TEST
KIT
EA
WT Test Kits MP Chloride test kits CHLORIDE HP TEST
KIT
EA
WT Test Kits Evaporator Test Kit 1ppm increments
CHLORIDE HP TEST
KIT
EA
WT Test Kits 6 month refill CHLORIDE HP TEST
KIT
EA
WT Test Kits LP Chloride test kits CHLORIDE LMP TEST
KIT
EA
WT Test Kits TEST EQPT CONDUCTIVITY CYLINDER, 100 ml
EA
WT Test Kits Cooling Water Test Kit CWT TITRETS per test EA WT Test Kits TEST EQPT DREWPLEX OX
ACTIVATOR SOL'N, 6 x 7 mls
EA
WT Test Kits TEST EQPT DREWPLEX OX
AMPOULE REFILL
EA
WT Test Kits Oxygen Scavenger test kit DREWPLEX OX
AMPOULE TEST KIT
EA
WT Test Kits Oxygen Scavenger High Range Test Kit
DREWPLEX OX
LAYUP, per test
EA
WT Test Kits 6 month refill DREWPLEX OX LAYUP, per test
EA
WT Test Kits TEST EQPT DROPPER PIPET EA WT Test Kits TEST EQPT EVAPORATING DISH EA WT Test Kits TEST EQPT FILTER PAPER, 100 sheets
EA
WT Test Kits TEST EQPT FUNNEL, PLASTIC EA WT Test Kits TEST EQPT GALLIC ACID, 30 grams EA WT Test Kits TEST EQPT GRADUATED
CYLINDER, 100 ml
WT Test Kits TEST EQPT GRADUATED
CYLINDER, 50 ml
EA
WT Test Kits Hydrate-Alkalinity Test Kits HYDRATE ALAKLINITY
TEST KIT
EA
WT Test Kits T-Alkalinity Test Kits LP ALKALINITY
TITRATION ASSEMBLY
EA
WT Test Kits TEST EQPT N/10 SULFURIC ACID, 1000 ml
EA
WT Test Kits TEST EQPT N/50 SULFURIC ACID, 1000 ml
EA
WT Test Kits TEST EQPT NESSLER TUBES EA WT Test Kits P-Alkalinity Test Kits PHENOPHTHALEIN
INDICATOR, 120 ml
EA
WT Test Kits MP Phosphate Test Kit PHOSPHATE
AMPOULE TEST KIT
EA
WT Test Kits LP Phosphate Test Kit PHOSPHATE
AMPOULE TEST KIT
EA
WT Test Kits LP Phosphate Test Kit PHOSPHATE VACU-
VIALS REFILL
EA
WT Test Kits Phosphate Test kit PHOSPHATE VACU-
VIALS TEST KIT
EA
WT Test Kits TEST EQPT PHTHALEIN RED
COMPARATOR SLIDE
EA
WT Test Kits TEST EQPT PHTHALEIN RED
INDICATOR SOL'N, 500
ml
EA
WT Test Kits Pocket pH Meter POCKET pH METER EA WT Test Kits TEST EQPT SILICA A-9000
NEUTRALIZER SOL'N,
6 x 7 mls
EA
WT Test Kits TEST EQPT SILICA A-9001 ACTIVATOR SOL'N, 6 x 7 mls
EA
WT Test Kits TEST EQPT SILICA AMPOULE
REFILL
EA
WT Test Kits Silica Test Kit SILICA AMPOULE
TEST KIT
EA
WT Test Kits TEST EQPT STIRRING ROD EA WT Test Kits TEST EQPT TOTAL ALKALINITY
INDICATOR GP, 120 ml
EA
WT Test Kits Hardness Test Kit TOTAL HARDNESS
TITRETS
EA
WT Test Kits pH Test Kit WATER ANALYZER
BASE
CHAPTER IV. – WATER TREATMENT PRODUCTS
CHAPTER IV. – WATER TREATMENT PRODUCTS
CONTRACT PRODUCTS LIST
BOILER WATER CHEMICAL TREATMENT
DREWPLEX OX CORROSION INHIBITOR
Description:
Application And Use:
Packaging:
SLCC-A CONDENSATE CORROSION INHIBITOR
Description:
Application And Use:
Packaging:
ADJUNCT B PHOSPHATE BOILER WATER TREATMENT
Description:
Application And Use:
Packaging:
GC CONCENTRATED ALKALINE LIQUID
Description:
Application And Use:
Packaging:
DREWPLEX AT BOILER WATER TREATMENT
Description:
Packaging:
DIESEL ENGINE COOLING SYSTEM TREATMENT
HIGH SPEED DIESEL ENGINES
MAXIGARD DIESEL ENGINE WATER TREATMENT
Description:
Application And Use:
Packaging:
DIESEL ENGINE JACKET WATER USED IN EVAPORATOR FEEDHEATERS
LIQUIDEWT ENGINE COOLING WATER TREATMENT
Description:
Application And Use:
Packaging:
DIESEL ENGINE ANTIFREEZE
PROPYLENE GLYCOL TECHNICAL GRADE ANTIFREEZE
Description Application And Use:
Packaging:
EVAPORATOR FEED INLET TREATMENT SYSTEM
AMEROYAL® EVAPORATOR TREATMENT
Description:
Application And Use:
Packaging:
SEAWATER ANTI-FOULING DISPERSANT
DREWSPERSE SWD SEAWATER DISPERSANT
Description:
Application And Use:
Packaging:
CLOSED LOOP FRESH WATER COOLING SYSTEM BIOCIDE
BIOSPERSE 255 WATER TREATMENT MICROBIOCIDE
(AMERSPERSE 280 OUTSIDE USA)
Description:
Application And Use:
Packaging:
SHIPBOARD TEST KITS
Conductivity Meter/Probes Meter Specifications, Kit Contents And Capabilities:
Meter Specifications Contents: Conductivity Kit Complete
Pocket pH Meter Pocket pH Meter Specifications Pocket pH Meter Kit Contents
Test Equipment And Spare Parts
Propulsion Boiler 900 Psig Kit Contents And Capabilities:
Propulsion Boiler 600 Psig (For Attachment E, Section 2.B) Kit Contents And Capabilities:
DREWPLEX Ox Refill Auxiliary Boilers Kit Contents And Capabilities:
Testing Boilers In Wet Lay-Up Testing For Chlorides In Distillate Diesel Engine Water Testing Kit Contents And Capabilities:
IV.A. WATER QUALITY
IV.a.1. Contamination IV.A.1.a. Effects Of Contaminants IV.A.1.b. Requirements For Feedwater (All ships) IV.A.1.b.1. Distillate IV.A.1.b.2. Reserve And Makeup Feedwater IV.A.1.b.3. Main And Auxiliary Condensates, Drains IV.A.1.b.4. Shore Steam And Condensed Shore Steam Used As Feedwater IV.A.1.b.5. Shore Processed Feedwater (Demineralizers, Reverse Osmosis) IV.A.2. Principles of Corrosion and Deposit Growth Formation IV.A.2.a. Introduction and goals IV.A.2.b. Corrosion IV.A.2.b.1. Corrosion: Defined IV.A.2.b.2. Types / Causes of Corrosion IV.A.2.b.3. Dissolved Gases IV.A.2.b.3.1. Oxygen:
IV.A.2.b.3.2. Carbon Dioxide:
IV.A.2.b.3.3. Ammonia:
IV.A.2.b.4. Acid Corrosion - Acid Attack IV.A.2.b.5. Hydrogen Attack IV.A.2.b.6. Caustic Corrosion IV.A.2.b.7. Caustic Cracking Corrosion IV.A.2.b.8. Corrosion Fatigue IV.A.2.c. Composition and Formation of Deposits IV.A.2.c.1. Dissolved Inorganic Solids IV.A.2.c.2. Slightly Soluble Solids IV.A.2.c.3. Insoluble Solids
IV.B. WATER PURIFICATION
IV.B.1. Evaporators IV.B.1.a. Distillation Process IV.B.1.b. Evaporator, Flash Type IV.B.1.c. Evaporator, Thin-Film Type IV.B.1.d. Evaporator, Submerged Tube Type IV.B.1.e. Evaporator, Vapor Compression Type IV.B.1.f. Evaporator, Plate Type IV.B.2. Operating Problems IV.B.2.a. Evaporator Scaling IV.B.2.b. Evaporator Foaming and Carryover IV.B.3. Evaporators, Control limits, Treatment Actions (Chemical and Physical), Injection Points.72 IV.B.3.a. Control limits
IV.B.3.b. Treatment Actions (Chemical and Physical), Injection Points IV.B.3.b.1. Treatment Actions (Physical)
IV.B.3.b.2. Treatment Actions (Chemical) IV.B.4. Reverse Osmosis (R/O) IV.B.5. Deaeration IV.B.5.a. Deaeration Process IV.B.5.b. Deaeration: Pressure/Temperature Table for Deaerator Checks
IV.C. BOILER OPERATIONS/BOILER WATER TREATMENT
IV.C.1. General Operation and Circulation IV.C.1.a. Initial Treatment IV.C.1.b. Steaming Boilers IV.C.1.c. Water Treatment Prior To Securing IV.C.2. Chemical Treatment Theory IV.C.2.a. Alkalinity and Phosphate IV.C.2.b. High pressure systems, Coordinated phosphate – pH System IV.C.2.c. Blowdown Control IV.C.2.c.1. Surface Blowdown (Where Fitted) IV.C.2.c.2. Surface Blowdown Procedure IV.C.2.c.3. Bottom Blowdown IV.C.2.d. Chemical Scavenging of Oxygen IV.C.2.e. Steam Line Corrosion Control IV.C.3. Waste Heat Recovery (Economizer) IV.C.3.a. Corrosion, Scaling and Problems IV.C.3.b. Treatment Actions (Physical) IV.C.3.c. Treatment Actions (Chemical) IV.C.3.d. Control limits using DREWPLEX AT/OX program IV.C.4. Medium Pressure Boilers: Propulsion boilers, below 850 psig design pressure.96 IV.C.4.a. Treatment Actions (Physical) IV.C.4.b. Treatment Actions (Chemical), Injection Points IV.C.4.c. Control limits IV.C.4.d+ Special note for 3 boiler vessels or any other vessels using simmering coil to maintain steam pressure for preservation (USNS Shughart, Soderman):
IV.C.5. High-Pressure Boilers: Propulsion boilers, above 850 psig design pressure ..100 IV.C.5.a. Treatment Actions (Physical) IV.C.5.b. Treatment Actions (Chemical) IV.C.5.c. Control limits
IV.D. COOLING WATER TREATMENT/HEAT EXCHANGERS
IV.D.1. Salt Water to Fresh Water IV.D.1.a. Corrosion, Scaling and Problems IV.D.1.b. Treatment Actions (Physical) IV.D.1.c. Treatment Actions (Chemical) IV.D.2. Engine Cooling Water (Fresh Water) IV.D.2.a. Water Impurities IV.D.2.b. Chemical Treatment, Theory IV.D.2.c. Treatment Actions (Chemical and Physical) IV.D.2.c.1. Physical Actions IV.D.2.c.1.1. Water Requirements IV.D.2.c.2. Chemical Actions IV.D.2.c.2.1. Initiating Coolant Treatment IV.D.2.c.2.2. Fresh Fill And Treatment Of Cooling Systems IV.D.2.c.3. Control limits IV.D.2.c.4. Treatment Actions (for Biological growth)
IV.D.2.c.5. Sampling Frequency IV.D.3. Emergency (Small) Diesel Engine Treatment
IV.D.3.a. Inhibited Antifreeze Treatment IV.D.3.a.1. Limits IV.D.3.a.2. Treatment Dosages IV.D.3.a.3. Sampling Frequency IV.D.3.a.4. Action For Out-Of-Limits Results
IV.E. LAY-UP PROCEDURES/SPECIAL IDLE/DRY AND WET
IV.E.1. Low Speed Steaming IV.E.2. Standby and Idle Boilers, principle IV.E.2.a. Dry Lay-up IV.E.2.b. Wet Lay-up IV.E.2.c. Steam Blanketing IV.E.2.b.1. Boiler Empty IV.E.2.b.2. Boiler In Operation IV. E.3. Boiler “out-of-service” preservation, procedure IV.E.4 Fresh water cooling systems in ROS or out of service condition IV.E.4.1 Testing Frequency of Fresh Water Cooling Systems During Lay-Up Periods ..116
IV.F. QUANTITATIVE ANALYSIS
IV.F.1. Sampling IV.F.1.a. Sampling Procedures IV.F.1.b. Sampling Equipment IV.F.1.c. Obtaining Samples for Shipboard Tests IV.F.1.d. Obtaining Samples for Laboratory Testing IV.F.1.e. Sampling Points IV.F.1.e.1. Boiler Water IV.F.1.e.2. Condensate and Feed IV.F.1.e.3. Makeup Water and Evaporator Distillate IV.F.1.e.4. Closed Loop Cooling Water IV.F.1.e.5 Fuel Storage Tanks, Biological Testing IV.F.1.f. Time IV.F.2. Maintenance of Test Equipment IV.F.2.a. Burettes maintenance and use IV.F.2.b. Test Cabinet Condition IV.F.2.c. Cleaning Glassware And Plasticware IV.F.3. Reagents IV.F.3.a. Reagents and Sampling: Introduction IV.F.3.b. Preparation of Reagents IV.F.3.c. Deterioration of Testing Chemicals IV.F.3.d. Indicators IV.F.4. Testing Technique IV.F.4.a. Use of Colorimetric Equipment IV.F.4.a.1. Use of Water Analyzer, General IV.F.4.b. Proper Measuring Spoons IV.F.4.c. Reading Calibrated Glassware IV.F.4.d. Filter Paper IV.F.4.e. Burette Titration IV.F.4.f. Dilution of Samples IV.F.5. Electrometric Methods IV.F.5.a. Conductivity Test Equipment IV.F.5.b. Salinity Indicators And Feedwater Conductivity Cells IV.F.5.c. Salinity And Conductivity Indicating Equipment Malfunction
IV.F.6. Troubleshooting IV.F.6.a. Possible Problem Areas
IV.F.6.b. Problems In Sampling IV.F.6.b.1. Reserve Feedwater IV.F.6.b.2. Feedwater IV.F.6.b.3. Boiler Water IV.F.6.b.4. Sample Cooler Leakage IV.F.6.c. Troubles with Boiler Chemical Injection IV.F.6.d. Severe contamination IV.F.6.d.1. Carryover
IV.G. RECORD KEEPING AND REPORTING
IV.G.1. Record Keeping IV.g.2. Expression of Chemical Dosages IV.G.3. Expression of Chemical Results IV.G.3.a. Reporting of Quantity IV.G.3.a.1. Parts Per Million (ppm) IV.G.3.a.2. Parts Per Billion (ppb) IV.G.3.a.3. Equivalents Per Million (epm) IV.G.3.B. Reporting of pH IV.G.3.c. Reporting of Dissolved Solids Concentration as Conductivity
CONTRACT PRODUCTS LIST
Treatment Tradename PCN Application Phosphate ADJUNCT B 0001-62-8 Steamships Alkalinity Control GC 0007-40-2 Steamships Condensate Treatment SLCC-A 0011-40-3 Steamships Oxygen Scavenger DREWPLEX OX 6623-40-0 All Low Pressure Phosphate DREWPLEX AT 6598-40-5 Motorships Diesel Coolant Treatment MAXIGARD 0034-40-5 All Diesel Engine Central Cooling LIQUIDEWT 0097-40-3 Motorships Evaporator Feedwater Treatment AMEROYAL 0024-40-6 All Seawater System Anti-Fouling Dispersant
DREWSPERSE SWD 5148-40-9 All
Closed Loop Cooling System Biocide BIOSPERSE 255
(CONUS+HI) /
AMERSPERSE 280
Outside CONUS
4303-40-0
0076-40-7
All
Propylene Glycol Propylene Glycol 3697-26-7 Motorships NOTE: Gas Turbine ships are included in Motorships
The following Section is excerpted from the Statement of Work agreed upon by MSC and Drew Marine.
It is designed to inform the user about what products and kits are in each program and give details of each water treatment program.
BOILER WATER CHEMICAL TREATMENT
NOTE: All boiler water treatment programs products described below meet 21 CFR 173.310 requirements for hydrazine content (0 ppm) and morpholine content (10 ppm) in steam that comes into contact with food.
Boiler Water Specifications:
Drew Marine Division (DM) offers its ULTRAMARINEsm Program of treatment for 900 psig boilers, which is our proven adaptation of the "Coordinated Phosphate - pH" principle for effectively treating high-pressure boilers of the design found in the marine industry. Prior to DM introducing its Ultramarine
Program, caustic corrosion was one of the most frequent and most serious causes of damage to high-pressure boilers. The "Coordinated Phosphate-pH" system for controlling boiler water chemistry was developed to prevent caustic corrosion and the resulting failures. The DM ULTRAMARINE adaptation of the Coordinated Phosphate principle assures that concentration of the boiler water-even evaporation to dryness-can never produce any excess, or "free" caustic soda which would bring about caustic corrosion in the boiler.
The program offered will provide control of the following parameters:
(a) Propulsion Boiler 900 psi
Boiler pH 9.8-10.2
Phosphate 15-25 ppm
Condensate pH 8.6-9.0
DREWPLEX OX (DEHA) 0.2-0.5 ppm
Conductivity 120 µmhos maximum
DM offers its Standard Treatment Program for 600 psig boilers, as the serious problems associated with free caustic are not present. Both the ULTRAMARINESM and Standard Programs of boiler water treatment utilize the water treatment chemicals described below.
(b) Propulsion Boiler 600 psi
P Alkalinity 90-130 ppm
T Alkalinity < 2 times P. Alkalinity
Condensate pH .3-8.6
DREWPLEX OX (DEHA) 0.2-0.5 ppm
Conductivity 600 µmhos
DM offers its DREWPLEX® AT and DREWPLEX OX Program for low-pressure boilers (under 200 psig). DREWPLEX AT is a multi-functional boiler water conditioning and steam line/condensate corrosion control product that contains phosphate, alkali, and morpholine along with several polymers to disperse sludges and sequester scale. DREWPLEX OX is a non-hydrazine oxygen scavenger, diethylhydoxylamine (DEHA), that provides oxygen scavenging and iron oxide reduction similar to hydrazine, but with much less toxicity and no know carcinogenic properties. DREWPLEX OX is catalyzed to function at low temperatures, thus insuring that oxygen scavenging will take place at its dosing point under all steaming conditions.
c) Low Pressure Auxiliary Boilers
Hydrate Alkalinity 40-65 ppm
Phosphate 10-20 ppm
Condensate pH .3-8.6
DREWPLEX OX (DEHA) 0.4-0.8 ppm
Conductivity 700 µmhos
DREWPLEX® OX CORROSION INHIBITOR
DESCRIPTION:
DREWPLEX OX corrosion inhibitor is a liquid solution of diethylhydroxylamine (DEHA) and a proprietary non-hazardous catalyst. It is used to control ferrous and non-ferrous corrosion in boilers and of steam, condensate and feedwater lines. DREWPLEX OX corrosion inhibitor reacts with dissolved oxygen, producing no dissolved solids in the boiler water. It forms a protective oxide film on both iron and copper surfaces.
APPLICATION AND USE:
Dosage: DREWPLEX OX corrosion inhibitor should be dosed continuously to the feed water to maintain its concentration within the specified range on the appropriate control charts furnished by DM.
Slug dosing and/or improper control of the DEHA concentration will not provide adequate protection of the boiler system. It may lead to an accumulation of ammonia in the condensate that could possibly corrode copper alloy tubes.
Feeding: For low and medium pressure systems DREWPLEX OX corrosion inhibitor should be dosed continuously by pump to the feed pump suction on steam ships.
Testing: DEHA concentration in the boiler water should be tested daily.
Additional Data: DREWPLEX OX corrosion inhibitor can also provide protection for boilers in lay up.
TYPICAL PHYSICAL PROPERTIES
Appearance: Clear yellow liquid
Specific Gravity @25°C: 1.0
Flash Point: 62°C pH 8.8
PACKAGING:
This product is packaged in 25 liter pails.
SLCC-A CONDENSATE CORROSION INHIBITOR
SLCC-A condensate corrosion inhibitor is a liquid alkaline volatile amine. It is used to control corrosion in condensate return lines and on steam condensing surfaces by traveling and condensing with the steam. SLCC-A neutralizes the corrosive effects of carbonic acid formed by carbon dioxide and maintains non-corrosive pH conditions from the point of condensation onward throughout the system.
APPLICATION AND USE:
Dosage: SLCC-A condensate corrosion inhibitor should be dosed continuously to maintain the pH range specified on the appropriate DM control charts. Slug dosing may result in erratic pH conditions and/or triggering a false condensate salinity alarm.
Feeding: SLCC-A condensate corrosion inhibitor should be fed using a metering pump along with the
DREWPLEX OX.
Testing: Condensate pH should be tested daily.
Appearance: Clear viscous liquid
Specific Gravity @ 25°C 1.0
Odor: Slightly ammoniac
This product is normally packaged in 25 liter pails.
ADJUNCT® PHOSPHATE BOILER WATER TREATMENT
ADJUNCT B phosphate boiler water treatment is a pure neutral grade of disodium phosphate. It is used in conjunction with GC concentrated alkaline liquid to prevent calcium scale deposits in propulsion boilers. Calcium hardness is converted to soft, non-adherent sludge that can be easily removed by blowdown.
APPLICATION AND USE:
Dosage: 0.85 ppm of ADJUNCT B should be dosed to fresh water make-up for each ppm of calcium hardness (as CaCO3), plus an amount necessary to maintain a small excess in the boiler water. After testing for phosphate (ppm PO4), the required ADJUNCT B dosage can be determined from the appropriate control chart furnished by DM. 1.5 grams of this product per metric tonne of distilled water gives 1.0 ppm phosphate.
Feeding: ADJUNCT B phosphate boiler water treatment should be dissolved in condensate and fed directly to the steam drum (below water level) by means of a bypass pot feeder or chemical injection pump.
TYPICAL PHYSICAL PROPERTIES
Appearance: White free-flowing granules
Density: 1.06 gm/cm3 pH: 8.9 (1% solution)
Solubility in water: 10% @ 24°C
This product is normally packaged in 25 kg fiber kegs.
GC CONCENTRATED ALKALINE LIQUID
GC concentrated alkaline liquid is a concentrated alkaline liquid used in conjunction with Adjunct B phosphate boiler water treatment to prevent the formation of calcium and magnesium scale deposits in propulsion boilers. Hardness constituents are converted to soft, non-adherent sludge that is easily removed by blowdown.
APPLICATION AND USE:
Dosage: After testing the boiler water alkalinity and/or pH, the required GC dosage is determined from the appropriate control chart furnished by DM. 1.0 milliliter of this product per metric ton of distilled water give 0.5 ppm alkalinity.
Feeding: GC concentrated alkaline liquid should be mixed with condensate and fed directly to the steam drum (below water level) be means of a bypass pot feeder or chemical injection pump.
Additional Data: GC concentrated alkaline liquid can also be used as a neutralizing agent following acid cleaning with SAF-ACID descaling compound also provided under this contract.
TYPICAL PHYSICAL PROPERTIES:
Appearance: Clear Liquid
Specific Gravity @ 25°C: 1.5
This product is normally packaged in 25 liter steel pails.
DREWPLEX AT BOILER WATER TREATMENT
DREWPLEX AT boiler water treatment is a phosphate-based treatment combined with synthetic polymers providing the ultimate in simplicity, system flexibility and treatment control for all low-pressure auxiliary and exhaust gas boilers. DREWPLEX AT boiler water treatment provides a cleaner boiler by allowing greater tolerance of feedwater quality fluctuations.
The polymers in DREWPLEX AT boiler water treatment serve as deposit control agents by adsorbing onto the surface of boiler water precipitates, keeping the particles soft, non-adherent and easily transported through blowdown.
In addition to combining alkalinity control, scale inhibitors and deposit control, DREWPLEX AT boiler water treatment provides protection from corrosion in the after-boiler section caused by low pH.
TYPICAL PHYSICAL PROPERTIES
Appearance: Light, brown liquid
Specific Gravity @ 25°C 1.056 pH: 13.4 (neat)
Flash Point None
This product is normally packaged in 25 liter pails.
DIESEL ENGINE COOLING SYSTEM TREATMENT
NOTE: The diesel engine cooling water treatments products described below are compatible with propylene glycol at any concentration. None of the products contains hexavalent chromate or other heavy metals.
HIGH SPEED DIESEL ENGINES
MAXIGARD DIESEL ENGINE WATER TREATMENT
DESCRIPTION:
MAXIGARD diesel engine water treatment is DM's premium multi-functional treatment designed to prevent corrosion and mineral scale in recirculating cooling water systems for medium and high-speed marine diesel engines. MAXIGARD treatment is concentrated in strength and colored for ease of visibility. It is also suitable for treating chilled water and many other recirculation systems. MAXIGARD diesel engine water treatment has been thoroughly field tested and is approved by over 30 major marine engine manufacturers. MAXIGARD is safe for use in treating cooling water that is used as the heat source in evaporator systems used to produce distilled water for human consumption.
APPLICATION AND USE:
System Preparation: Prior to initiating MAXIGARD diesel engine water treatment, the cooling system should be drained and flushed with fresh water . If the system is contaminated, it is essential that it be chemically cleaned before beginning treatment. Sacrificial (Magnesium or Zinc) anodes in the cooling system should be removed prior to adding the MAXIGARD treatment. These materials are unnecessary in systems treated with MAXIGARD and can cause undesirable deposits in the circulating water system. Even though MAXIGARD is effective in multi-metal system, certain aluminum alloys may be difficult to protect, because they are highly anodic. The use of MAXIGARD with systems having complex multimetal designs should be reviewed with the DM Technical Manager (TM) prior to starting or changing treatment.
Dosage: The system should be filled with distilled or fresh water and where freeze protection is necessary, the proper amount of glycol-based antifreeze should be added. Begin circulating the system and add MAXIGARD at an initial dosage of 16 liters per metric ton or 1.6 U.S. gallons per 100 U.S.
gallons of system capacity (2 ozs per gallon). This will provide a treatment level of 20,000 ppm.
Circulate the coolant in the system for 30 minutes after addition to insure good distribution and the establishment of the protective film. MAXIGARD diesel engine water treatment may be used with waters that have minor contamination, provided the chloride levels are below 100 ppm or as otherwise recommended by the engine manufacturer, whichever is less.
Testing and Control: The proper level of MAXIGARD diesel engine water treatment can be maintained using the CWT Titret Test Kit (product code 0367-01-2) provided by DM. Tests should be conducted after adding treatment to confirm the MAXIGARD concentration of 20,000 ppm is present.
Normally testing once each week is satisfactory or whenever changes are noticed. Testing for chloride may be conducted to check makeup water quality. Chloride levels should not exceed 100 ppm or the engine manufacturer's recommendation, whichever is less.
Note that while normal over treatment with MAXIGARD presents no problem, concentrations more than twice the recommendation should be avoided. MAXIGARD diesel engine water treatment is compatible with glycol-based antifreezes and non-metallic components such as hoses and seals. It is important to note that when testing systems containing antifreeze solutions, there may be test interference.
Appearance: Clear Red-Violet Liquid
Specific Gravity: 1.2 pH, Undiluted: 11.8
Freeze Point: -17°C (1.4°F)
Freeze-Thaw Stability: Complete
Flash Point: None
PACKAGING:
MAXIGARD diesel engine water treatment is normally supplied in 25 liter pails.
DIESEL ENGINE JACKET WATER USED IN EVAPORATOR FEEDHEATERS
LIQUIDEWT ENGINE COOLING WATER TREATMENT
DESCRIPTION:
LIQUIDEWT cooling water treatment is a multi-functional corrosion inhibitor for protecting recirculating cooling and heating water systems. LIQUIDEWT treatment is approved or authorized for use by MAN, B&W, Sulzer, Wartsila, U.K. Department of Transport, Akasaka, Mitsubishi and Deutz MWM.
LIQUIDEWT is safe for use in treating cooling water that is used as the heat source in evaporator systems used to produce distilled water for human consumption.
APPLICATION AND USE:
System Preparation: LIQUIDEWT cooling water treatment is an effective corrosion inhibitor for all ferrous and non-ferrous metals normally used in marine circulating cooling water systems. In order to ensure the maximum benefits from a LIQUIDEWT treatment program, the system should be inspected for deposits and corrosion. If the system is contaminated, it must be chemically cleaned before the treatment program is begun. Prior to the addition of LIQUIDEWT treatment, sacrificial anodes (e.g., magnesium or zinc) in the cooling systems should be removed. These are not necessary with the complete chemical program in effect and, in fact, may cause undesirable deposits in the circulating water system.
Dosage: Good quality fresh or distilled water can be used to fill the system. Where freezing conditions are a possibility, the proper amount of glycol based antifreeze should also be added. Begin circulating the engine cooling water with an initial dosage of 8 liters (2.13 US gallons) of LIQUIDEWT cooling water treatment per metric tonne of system capacity. This will provide a treatment level of approximately
10,000 ppm. The initial charge should be circulated for 30 minutes to insure good distribution.
LIQUIDEWT treatment may be used with waters that have minor contamination. The chloride level in the cooling system should be limited to 100 ppm or as otherwise recommended by the engine manufacturer, whichever is less.
Testing and Control: The proper concentration of LIQUIDEWT treatment can be maintained using the
CWT Titret test kit (P.C 0367-01-2). Tests should be conducted to confirm that a minimum LIQUIDEWT treatment concentration of 10,000 ppm is present. Testing will also confirm that you have not exceeded our recommended maximum of 15,000 ppm of LIQUIDEWT treatment. Normally, testing once each week is satisfactory; however, whenever changes are noticed, testing should be increased. In addition to testing for the concentration of LIQUIDEWT treatment, testing for chloride levels should be conducted periodically to detect possible seawater contamination. Chloride levels must not exceed 100 ppm or the engine manufacture's recommendations, whichever is less. LIQUIDEWT treatment is compatible with glycol-based antifreezes and most system components such as hoses, seals and packing. Concentration test results may vary slightly when the system is treated with commercial antifreezes. LIQUIDEWT contains no chromate.
Appearance: Light Yellow Liquid
Specific Gravity: 1.24 pH, Neat @ 25° C: 12.6
Freeze Point: -12.2°C (10°F)
Freeze/Thaw Stability: Complete
Flash Point: None
LIQUIDEWT cooing water treatment is normally supplied in 25 liter pails.
DIESEL ENGINE ANTIFREEZE
PROPYLENE GLYCOL TECHNICAL GRADE ANTIFREEZE
DESCRIPTION
DM will provide Propylene Glycol for freezing protection. Propylene Glycol is a colorless, practically odorless, low-volatile, low-viscosity, hygroscopic liquid. It is completely miscible with water and compatible with the cooling water treatments offered in this proposal.
APPLICATION AND USE:
Propylene glycol is used in Diesel engines cooling water systems in conjunction with corrosion inhibitors to lower the freezing point of water without significantly reducing its cooling effect. It also counteracts the swelling of rubber parts and retards foam formation.
DOSAGE RATES:
FREEZE POINT(°C) PERCENT IN WATER
0 0%
-10 30 %
-20 42 %
-30 50 %
TYPICAL PHYSICAL PROPERTIES
Appearance: Colorless liquid
Specific Gravity @25°C: 1.038
Flash Point (PMCC): 108°C
Propylene glycol is typically sold in 208 liter drums.
EVAPORATOR FEED INLET TREATMENT SYSTEM
AMEROYAL® EVAPORATOR TREATMENT
DESCRIPTION:
AMEROYAL evaporator treatment is a liquid combination of active polymer and antifoam agents used to prevent scale deposition in both low-pressure, moderate and high temperature evaporators.
AMEROYAL is proven effective in seawater, concentrated seawater such as that found in the Red Sea, brackish and fresh water. AMEROYAL may be used to remove existing scale deposits. AMEROYAL is safe for use in evaporators used to produce fresh drinking water for human consumption and contains no volatile components.
APPLICATION AND USE:
When seawater is treated with AMEROYAL evaporator treatment, the polymers prevent the scale forming minerals in the water from precipitating crystal growths in their normal manner. The scale forming crystal patterns are altered so that they cannot adhere tightly to themselves or the metal surfaces. The overall effect of treatment with AMEROYAL is that thin layers of material are continuously being deposited and removed from the heat transfer surfaces before they become thick enough to impair heat transfer. The detached solids are held in suspension and ultimately carried out of the evaporator with the overboard discharge brine. AMEROYAL treatment is diluted with fresh or sea water and fed continuously to the evaporator inlet line, directly to the evaporator shell or just prior to the salt water feed preheaters depending on equipment. AMEROYAL should be dosed using a proportioning pump or by a gravity feed system through a flow meter.
TYPICAL…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .