Annex 1502000 C FI Revised.pdf

PDF 498 KB Posted

Attached to
RANGE MAINTENANCE AND REPAIR SUPPORT
Solicitation number
N4008527R0004
Issued by

About this file

This is a Performance Work Statement (PWS) for Facility Investment maintenance and repair services at Marine Corps Base Camp Lejeune, North Carolina, covering 566 Training Facilities and 115 Live Firing Ranges. The contractor shall provide all labor, management, supervision, tools, targeted pest control, materials, and equipment to maintain facilities, ground structures, and installed equipment and systems in normal working condition.

Recurring maintenance work includes inspections, carpentry, welding, masonry, electrical work, painting, material transportation, and repairs to aiming stakes, firing points, ammunition tables, bleachers, signs, fences, flag poles, ammo breakdown tables, drainage ditches, monuments, traffic control devices, and waterfront/airfield infrastructure. All alterations, demolition, and minor construction shall not exceed $2,000 per project. Urgent service orders (responding within 8 hours, completing within 5 working days) are limited to 32 labor hours or $2,500 in material cost and address unsafe or degraded operational conditions. Routine service orders (responding within 24 hours, completing within 21 calendar days) are limited to 32 labor hours or $2,300 in material cost. The contractor shall conduct quarterly and annual range inspections with specific checklists and reporting requirements, completing annual inspections within 14 days and quarterly inspections within 30 days of initiation.

Non-recurring work includes tension load testing and certification of rappel points (every 5 years at 5,000 pounds in accordance with 29 CFR 1910.66 and ANSI Z359.1) and unexploded ordnance (UXO) grass cutting in high hazard impact areas quarterly (not exceeding 25 acres annually, cutting no less than 3 inches above surface grade). Personnel must hold minimum certifications including two persons with Commercial Class A CDL and one licensed welder in North Carolina. Work must comply with OEM training requirements, NAVFAC MO-200 for electrical/electronic work, NAVSEA OP-5 for ammunition facility grounding, UFC 3-600-02 for fire protection systems, and HAZMAT/HAZWASTE handling protocols. All completed service requests shall be submitted to Range Maintenance the same day or next business day, and monthly summaries of completed service orders are required.

View the file

Other files

Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DISTRIBUTION: DoW COMMUNITY ONLY

1502000 – Facility Investment Table of Content Spec Item Title 1 General Information

1.1 Concept of Operations

2 Management and Administration

2.1 Definitions and Acronyms

2.2 Personnel

2.2.1 Certification, Training, and Licensing

2.3 Special Requirements

2.3.1 Workmanship and Material Standards

2.3.2 Historical Preservation

2.4 References and Technical Documents

3 Recurring Work

3.1 Service Orders

3.1.1 Urgent Service Orders

3.1.1.1 Range Erosion Repair

3.1.2 Routine Service Orders

3.1.3 Quarterly Inspections for Ranges

3.1.4 Annual Inspections for Ranges

3.1.5 Range Inspection Procedures & Reporting

4 Non-Recurring

4.1 Tension Load Testing and Certifying Rappel Points

4.2 UXO Grass Cutting

1502000 – Facility Investment Spec Item

Title Description

1 General Information

The Contractor shall provide all labor, management, supervision, tools, targeted pest control, material, and equipment required to perform Facility Investment services for facilities, ground structures, and installed equipment and systems at Range Maintenance Support, Marine Corp Base, Camp Lejeune, NC. This contract will include five hundred sixty-six (566) Training Facilities and one hundred-fifteen (115) Live Firing Ranges.

1.1 Concept of

Operations

Range maintenance tasks will consist of general repairs necessary to keep ranges and training areas in usable condition. The tasks include, but are not limited to:

inspections of the Ranges, carpentry, welding, masonry, electrical, painting, and other various types of maintenance work, and transporting materials and equipment to sites.

Types of work include, but are not limited to: fabricating, installing and repairing metal gates, fabricating and installing metal barriers, fabricating, installing and repairing flag poles, signs (lateral limit, range identification, impact area, no trespassing etc. metal and wood), repair/replace Range Maintenance ammo tables, wooden steps located on ranges, repair to structures/facilities, berm maintenance, firing position maintenance, bunkers, retaining walls of wood or sandbags and metal, bleachers, and wooden steps berm maintenance bunkers retaining walls, repair/replace lateral limit signs, range firing lane markers, commercial cleaning/janitorial, pressure washing, UXO/impact area grass cutting, replacing SACON wall panels, repairing rappel towers, and testing rappel points. All alterations, demolition and minor construction shall not exceed the amount of $2,000. Notification of maintenance requirements will be accomplished via written service requests (Work Authorization) for routine and urgent maintenance.

The Contractor shall submit all completed Service Requests to Range Maintenance (Point of contact to be provided at time of award). The same day the work is completed or the next business day.

The Contractor shall perform maintenance, repair, alteration, demolition and minor construction for the following:

-Aiming Stakes (Rubber/Wood) -Firing Point (Repair/Replace) -Material Transportation (Targets, Lumber, Hulk, Jersey Barrier) -Windsocks and Frames -Ammon Tables (Metal/Wood) -Bleacher Maintenance (Metal/Wood) -Class 3 Property (Towers/Mount) -Firing Lane Markers (Repair/Replace/Dispose) -Signs -Fences -Ammo breakdown table repair -Drainage Ditches -Monuments -Flag Poles -Traffic Control Devices -Waterfront (Signs) -Inter Coastal Platforms (at entrances) -Airfields LZ’s (Camp Davis, North and South)

Spec Item

Title Description

2 Management and Administration

2.1 Definitions and

Acronyms

Definitions and Acronyms are listed in J-1502000-01.

2.2 Personnel The Contractor shall provide personnel with the qualifications, technical knowledge, experience and skills required for efficient operations within the Range Maintenance and Repair Support area.

2.2.1 Certification, Training, and Licensing

All maintenance and repair shall be performed by personnel trained and certified by the OEM.

Personnel working with or on electrical or electronic equipment must be trained and certified per NAVFAC MO-200.

Personnel conducting ground safety checks on lighting arrestors or grounding devices on facilities housing ammunition and explosives must be certified per NAVSEA OP-5.

Personnel working on fire protection systems must be certified per UFC 3-600-02.

Personnel performing work in HAZMAT/HAZWASTE must complete the HAZMAT/HAZWASTE handling course or have a minimum of one year of experience working with HAZMAT/HAZWASTE.

All maintenance trade personnel certifying or inspecting repair or maintenance work that does not require an inspector certified by a governing directive shall be qualified at the journeyman level.

Personnel Licensing Requirements:

A minimum of two (2) persons with Commercial Class A CDL A minimum of one (1) person be a Licensed Welder in the State of North Carolina The Contractor shall submit proof of all certifications, training, and licensing requirements per Section F.

Knowledge, Skills, and Abilities are listed in J-1502000-02

2.3 Special

Requirements

2.3.1 Workmanship

and Material Standards

The Contractor shall be responsible for maintaining all facilities, systems, and equipment, identified in this technical sub-annex, to a standard that prevents deterioration beyond that which results from normal wear and tear and corrects deficiencies in a timely manner to assure full life expectancy of the facilities, systems, and equipment. Best commercial practices shall be applied in the performance of work. All work shall be completed per approved and accepted industry and equipment manufacturers’ standards and shall comply with building and safety codes, applicable activity, local, state, and federal regulations, and other technical requirements identified within this technical sub-annex.

Workmanship for maintenance and repair shall include all work necessary to complete facility and system restoration, including touch-up painting and operational checks.

Upon completion of work, the Contractor shall ensure all facilities, systems, and equipment are free of missing components or defects which would affect the safety, appearance, or habitability of the facilities and structures or would prevent any electrical, mechanical, plumbing or structural system from functioning in accordance with design intent. Repairs shall be made in accordance with the manufacturers’ specifications and guidelines, and standard building codes. The quality of repairs shall meet the applicable standards and shall prevent any malfunction reoccurrences caused by poor workmanship or other contractor inadequacies. The quality of the repaired areas shall be fully compatible with adjacent surfaces or equipment. Except where

Spec Item

Title Description otherwise specified, replacements shall match existing in dimensions, finish, color, design, and functionality and shall have an appearance similar to the original finished appearance with only minor unobjectionable deterioration resulting from normal use.

The Contractor shall not allow debris to spread unnecessarily into adjacent areas nor accumulate in the work area. All such debris, excess material, and parts shall be cleaned up and removed at the completion of the job and at the end of each day work is in progress. Upon completion of work, any stains and other unsightly marks shall be removed.

2.3.2 Historical

Preservation

Buildings and facilities designated as historical sites shall be maintained in accordance with Federal, state and local historical policies and regulations.

2.4 References and

Technical Documents

References and Technical Documents are listed in J-1502000-03.

Spec Item

Title Performance Objective

Related Information Performance Standard

3 Recurring Work

The Contractor shall maintain, repair, and alter facilities, and installed equipment and systems to ensure they are fully functional and in normal working condition. Re- Occurring Maintenance work for the ranges is provided in J- 1502000-09.

Range maintenance tasks will consist of general repairs necessary to keep ranges and training areas in usable condition. The tasks include, but are not limited to:

transportation of moving equipment from one place to another, carpentry, welding, masonry, electrical, painting, wood façade repair and repainting, metal and wood prop fabrication, repair and movement, wood, metal and plastic sign fabrication, replacing and installation (Impact Area, Training Area, No Trespassing, UXO, informational etc.), wood and metal bleacher repair, inspections and other various types of maintenance work.

The Contractor shall provide all necessary test instruments, equipment, and tools required to perform maintenance and repair.

The current list for the facilities the Contractor will be providing maintenance is provided in J- 1502000-04.

Site maps are provided in J- 1502000-05 through J-1502000-05- 17.

Facilities, ground structures, and installed equipment and systems are in normal working condition and function properly in accordance with specified standards.

Spec Item

Title Performance Objective

Related Information Performance Standard

These tasks may include the need for Architectural and Engineering Design services.

3.1 Service Orders The Contractor

shall perform service order work in a timely manner and ensure facilities, ground structures, and installed equipment and systems are restored to a safe, normal working condition and function properly.

The Contractor shall receive service orders in accordance with the work reception requirements in Annex 2.

The Contractor shall schedule and perform service orders in a way that minimize disruptions to customers and Government operations.

The Contractor shall perform service orders to accomplish any work identified within the entire boundary of the installation and will include a wide variety of work.

Dimensions for the Range Table Design, Lateral Limit Sign Design, and the Range Firing Lane Markers are provided in J-1502000-07 through J-1502000-07-2.

Service Request Form (J-1502000-

08) and the Re-occurring Range Maintenance List (J-1502000-09) are provided.

Descriptions of the classifications of service orders (urgent and routine) are provided in the Definitions and Acronyms in J- 1502000-01.

The Contractor shall maintain sufficient materials and equipment on hand to support service order work requirements. Lack of availability of material or equipment will not relieve the Contractor from the requirement to complete service order work within the time limits specified.

The Government may combine multiple repair requirements received for the same trade in the same building or structure at the same time into one service order as long as the service order threshold is not exceeded.

Service order work is responded to and completed within the specified time.

Facilities, ground structures, and installed equipment and systems are restored to normal working condition, including recertification if applicable.

When repair is complete the facility, ground structure, or installed equipment and system does not present danger to personnel or equipment.

Spec Item

Title Performance Objective

Related Information Performance Standard

The Contractor shall notify the KO upon identification that the service order will exceed the liability limits specified below in accordance with reporting requirements in Annex 2.

If Non-recurring work is issued for repairs, the Government will only pay for the portion of labor and/or material that exceeds the service order limits.

The Contractor shall submit a monthly summary of completed service orders per Section F.

3.1.1 Urgent Service

Orders shall complete urgent service orders in a timely manner and ensure facilities, ground structures, and installed equipment and systems are restored to a safe, normal working condition and function properly.

The Contractor shall respond to Urgent maintenance requests within 8 hours after receipt of a Service Request and completed within five working days.

Urgent maintenance request are defined as maintenance required due to an unsafe or degraded operational training condition.

The Contractor shall perform urgent service orders to repair deficiencies without extended delay, therefore preventing further damage to facilities, ground structures, and installed equipment and systems.

Performance of urgent service calls is not required outside of Government regular working hours. Refer to “Government regular working hours” in Annex 2.

Urgent service orders are limited to a Recurring ceiling of 32 labor hours or $2,500 in material cost.

Urgent service orders are completed within five working days.

3.1.1.1 Range Erosion

Repair

The contractor shall hydroseed eroded areas on berms, firing lines, side banks and bald spots on ranges

The contractor shall use the Hydroseeding planting process.

Using a slurry of seed and mulch applied by a truck or trailer mounted spraying device. A man-pack version can also be used for small areas.

The contractor must prepare the area to be seeded by removing rocks and other debris from its surface.

Contractor shall rake the current soil or

Spec Item

Title Performance Objective

Related Information Performance Standard and training areas in order to repair or prevent erosion.

provide at least a 1-inch-deep layer of topsoil over the current soil and rake smooth to help the seeds take root.

Apply seed in accordance with manufacturers recommendations.

3.1.2 Routine Service

Orders shall complete routine service orders in a timely manner and facilities, ground structures, and installed equipment and systems are restored to a safe, normal working condition and function properly.

The Contractor shall respond to routine maintenance requests within 24 hours after receipt of a Service Request and complete the action within 21 days ensuring facilities and equipment, are restored to a safe, operable condition and function properly.

The Contractor shall perform routine service orders to repair deficiencies during Government regular working hours and return facilities, ground structures, and installed equipment and systems to normal working condition.

Routine service orders are limited to a Recurring ceiling of 32 labor hours or $2,300 in material cost.

Performance of routine service orders is not required outside of Government regular working hours.

Types of work include, but are not limited to, installing and repairing metal gates, flag poles, signs (metal and wooden), erecting and maintaining barricades, fencing, ammo breakdown tables, wooden steps located on ranges, impact area maintenance and repair, repair to structures/facilities, lateral limit signs, bunkers, retaining walls of wood or sandbags and metal bleachers.

Routine service orders are completed within 21 calendar days

3.1.3 Range

Maintenance Quarterly Inspections

The Contractor shall complete quarterly inspections in a timely manner per Section F.

The Contractor shall perform quarterly inspections and annotate any and all deficiencies found on the ranges during Government regular working hours.

The Live Fire Ranges and Training Facilities Locations (J-1502000-06 though J-1502000-06-7) are provided.

Inspections of the ranges are to be completed promptly.

Spec Item

Title Performance Objective

Related Information Performance Standard

Inspection Checklists (J-150200-10 through J-1502000-10-1) are provided. As well Inspection Frequencies and procedures (J- 150200-11 through J1502000-11-1)

3.1.4 Range

Maintenance Annual Inspections

The Contractor shall complete annual inspections in a timely manner per Section F.

The Contractor shall perform Annual inspections and annotate any and all deficiencies found on the ranges during Government regular working hours.

The Live Fire Ranges and Training Facilities Locations (J-1502000-06 though J-1502000-06-7) are provided.

Inspection Checklists (J-150200-10 through J-1502000-10-1) are provided. As well Inspection Frequencies and procedures (J- 150200-11 through J1502000-11-1)

Inspections of the ranges are to be completed promptly.

3.1.5 Range Inspection

Procedures & Reporting

The contractor shall use the Range Maintenance Inspection Checklist located in Attachment J- 1502000-11-2 for each Range inspected.

The contractor shall submit inspections reports and findings to the government electronically or by hard copy.

The contractor shall conduct and record the maintenance inspections in enough detail so that the government will be able to create a written Service Request by interpreting the findings and communicate the repair effort needed to effect repairs.

The contractor shall annotate on the checklist if the repair needs to be accomplished as soon as possible (ASAP). This would be an example of an Urgent Service Request.

Inspection Frequency:

The frequency of the Range Maintenance inspections shall be Annually or Quarterly as determined by the Range Inspections Frequency List.

Annual inspections to be conducted at the halfway point of the period of performance (POP). Annual inspections to be completed and findings turned into the Government within 14 days of the start date of the annual inspections.

Quarterly inspections to be conducted every three months starting with the beginning of the new POP for a total of (4) four inspections per POP. Quarterly inspections to be completed and findings turned into the Government within 30 days of the start date of

Spec Item

Title Performance Objective

Related Information Performance Standard the Quarterly inspections.

Spec Item

Title Performance Objective

Related Information Performance Standard

4 Non-recurring Work

The order will specify the exact locations and types of work to be accomplished.

All Non-recurring work issued will consist of the quantities that are exceeded in the Recurring work ELINs.

The period of performance will be specified in each order.

These tasks may include the need for Architectural and Engineering Design services.

Refer to Non-recurring ELINs for task listings, descriptions and related requirements. All periods of performance are measured from issue date of order to acceptance of the work.

Performance Standards for Non-recurring work will be the same as those in Spec Item 3 where applicable.

These tasks include, but are not limited to: carpentry, welding, masonry, electrical, painting, wood façade repair and repainting, metal and wood prop fabrication, repair and movement, wood, metal and plastic sign fabrication, replacing and installation (Impact Area, Training Area, No Trespassing, UXO, informational etc.), buoys, replacing SACON wall panels, wood and metal bleacher repair, inspections, commercial cleaning/janitorial, pressure washing, dust suppression, UXO grass cutting (NTE 25 Acres), Rappel Pont testing (to be completed every 5 years), and other various types of maintenance work. Work may include the Reoccurring Work provided in J-1502000-09.

Non-recurring Monthly Summary Report is submitted in a timely manner.

4.1 Tension Load

Testing and Certifying Rappel Points

Contractor shall test and certify Rappel Towers S755, RR211, and SRR495 and other points.

Rappel points should be tested at 5,000 lb. and in accordance with 29 CFR1910.66 Para (I)(c)(10), ANSI Z359.1, and 29 CFR1910.66 Appendix C(II)(a)(2) requirements. To be completed every 5 years.

Camp Lejeune Rappel Towers (J-1502000-05-14) are provided.

Perform and document results. The Contractor shall submit a report of testing by a licensed certified Structural Engineer of each point tested to the Government representative assigned.

4.2 UXO Grass

Cutting

Contractor shall provide UXO grass cutting quarterly in High Hazard Impact

Contractor shall perform UXO Grass Cutting in High Hazard impact areas quarterly to ensure that line of sight is not impeded

Contractor shall cut grass no less than three

(3) inches above

Areas aboard MCB Camp Lejeune NC for occupied units on ranges across the Camp Lejeune Training Complex. Not to Exceed 25 acres a year.

Site maps are provided in J- 1502000-05-15 through J- 1502000-05-18.

Minimum Qualifications for Unexploded Ordnance (J- 1502000-12) is provided.

surface grade on a quarterly basis.

Prior to initiating on site activities personnel must complete 3R UXO Safety Awareness Training and a roster should be provided to the MCB Camp Lejeune Explosives Safety Officer (ESO).

MCB Camp Lejeune Explosives Ordnance Disposal (EOD) on-call support must be provided during UXO Grass Cutting operations.

File details come from the government source that posted it. Updated .