This document provides details for a federal contract opportunity to renovate the HVAC system at Building 990 of the Naval Undersea Warfare Center in Newport, Rhode Island. The solicitation number is N4008523B2511 for the NUWC B-990 HVAC Renovation project at Naval Station Newport. Hazmat testing from 1975 indicated the presence of asbestos. The renovation involves upgrading the HVAC systems in buildings 990, 1319 and 1351. The Naval Facilities Engineering Command is the contracting agency. Bids are due by the date specified in the solicitation. The awarded contractor will be responsible for HVAC renovations that properly address the existing asbestos conditions.
View the file
Other files
Show 40 more
Latest 50 of 58 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NUWC HVAC: Design-Bid-Build HVAC upgrade in 990, 1319 & 1351
WON: 1621549
NUWC B990 HAZMAT Summary
YEAR BUILT: 1975
HAZMAT RESULT NOTES
Asbestos
<1% <1% detected in stair tower roof sample found in Asbestos Inspection for Building 990, 1319, 1320 and 1371, October 2017.
5% Chrysotile On Fiberglass Pipe Fitting at Chilled Water Supply 3% Chrysotile 1st Floor – Above
Ceiling 2% Chrysotile Behind Brick Façade
Near Louver Next to Main Mechanical Room Entrance
Lead Concentration (% Weight)
<0.0080 White Paint on Concrete Skim in Mechanical Lounge
<0.0080 Vanilla/Gray Paint on CMU Walls Mechanical Floor
0.020 White Paint on HVAC Metal Mechanical
Room
4.0 Black/Red Paint on Duct Frame in Mechanical
Room
<0.0080 Red/Black Paint on Steel Beam Support on Roof HVAC
<0.0080 Roof Over Black Paint on Mechanical Roof Top Unit
<0.0098 <0.0098% by wt detected in the Wallboard Paint Building 990 Room 613 found in Lead Paint Sampling for Buildings 990, 1319, 1320 and 1371, April 23, <0.0089 <0.0089 by wt detced in Wallboard Paint Building 990 Room 613 found in Lead Paint Sampling for Buildings
2.6443 2.6443% by wt detected in Lintel Paint Building 990 Exterior found in Lead Paint Sampling for Buildings
2.1022 2.1022% by wt detected in Lintel Paint Building 990 Exterior found in Lead Paint Sampling for Buildings
<0.0089 <0.0089% by wt detected in Dunnage Paint Building 990 Roof found in Lead Paint Sampling for Buildings
PCBs 0 None detected