N4008519R9186_E_2019-04-24_CTF_Drawing_Set_OTS_Review.pdf
PDF 3 MB Posted
- Solicitation number
- N4008519R9186
About this file
This special notice announces an industry day for a proposed military construction project at Naval Support Activity Crane in Crane, Indiana. The project involves construction of an Underwater Launch Test Facility including a 130-foot deep pool, operational support building, warehouse building, water treatment facility, and mechanical and electrical building. Site work will include excavation of the pool, paving, utilities and environmental mitigation. The magnitude of construction is estimated between $25 million and $100 million. Contractors are invited to attend presentations and a site visit on June 19-20, 2019 to learn more about the project and ask questions. Preliminary design documents will be posted to NECO by June 5, 2019. Interested firms should RSVP with attendee names by June 12, 2019. The notice provides contact information for the contracting office.
N4008519R9186_E_2019-04-24_CTF_Drawing_Set_OTS_Review.pdf
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
DN
A
C
C1
A-302
B
A1
A-402
/4
/4
T R
E A
D S
2" 3' - 8" 2"
INSTRUMENTATION
ROOM
LOCKABLE TOOL
CRIB
/4
13' - 11 1/2"
A
C
C1
A-302
B
A1
A-402
4' - 6"
14' - 3 1/4"
STORAGE
STAIR A
A
MEZZANINE LEVEL
11' - 0"
A
T.O. PURLIN @
HIGH BAY
27' - 0"
HIGH BAY ROOF
38' - 6"
B
FIRST FLOOR
LEVEL
0"
E Q
R
IS
E R
S
T Y
P
1' - 0"
11"
T Y
P
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
<<PM/DM>>
BRANCH MANAGER
CHIEF ENG/ARCH
<<XX>>
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
1/4" = 1'-0"
/2
/2
:0
:1 P
M
OSB-A-402
288101
C R
A N
E
IN
D
IA
N
A
Designer Author Checker
E N
L A
R G
E D
P L A
N S
N S
A C
R A
N E
U N
D E
R W
A T
E R
L A
U N
C H
T E
S T
F A
C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C T
F -A
-4
E N
L A
R G
E D
P L A
N S
1/4" = 1'-0"A4
ENLARGED INSTRUMENTATION
ROOM PLAN
1/4" = 1'-0"A3
ENLARGED MEZZANINE PLAN
1/4" = 1'-0"A1
SECTION @ STAIR A
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
O V
E R
T H
E S
H O
U L
D E
R R
E V
IE
W
/2 /2 stmurphy stmurphy Typewritten Text
CONCEPT DEVELOPMENT
15 15
E
-A-403
UNISEX TLT
UNISEX TLT
JAN. CL
6' - 1 1/2" 1' - 3 1/4" 6' - 7"
/2
5' - 0 1/4"
2' - 11 1/4"5' - 5 1/4"
4 4
1F
T2 T2
T1
T4
T9
T8
T5
T9
T5
T8
T8
T4
T1
C10 STL GIRT 3" THK INSULATED
METAL EXTERIOR PANEL
WALL MOUNTED
WATER CLOSET
ADA CLEARENCE
E
LIGHT FIXTURE.
SEE ELECT DWGS
EXHAUST GRILLE, TYP FIRE ALARM, TYP
LIGHT FIXTURE2' x 2' SUSPENDED
CEILING AT 8'-0" AFF,
TYP
UNISEX TLT
UNISEX TLT
JAN. CL
FIRST FLOOR
LEVEL
0"
CT-1 WALL FINISH
T2T2T2
T2
CT-2 FLOOR FINISH
CEILING AS
SCHEDULED
T4
T1
LIGHT FIXTURE
ELECTRIC
WATER HEATER
E
T1
T4
T9
T5
SCHEDULED
CEILING
LAVATORY.
SEE PLUMBING
ELECTRIC
WATER
HEATER
CT-1 WALL
FINISH
CT-2 FLOOR
FINISH
WALL MOUNTED TOILET
AND VALVE. SEE
PLUMBING
FIRST FLOOR
LEVEL
0"
SCHEDULED
CEILING
LIGHT FIXTURE
CT-1 WALL
FINISH
WALL MOUNTED
TOILET AND VALVE.
SEE PLUMBING DWGS
CT-2
FINISH
FLOOR
T8
T5
T9
WALL HEATER
E
HM DOOR
AND FRAME
SCHEDULED
CEILING
CT-1 WALL
FINISH
CT-2 FLOOR
CEILING
WALL
HEATER
T8
LIGHT FIXTURE.
SEE ELECT DWGS
CT-1 CERAMIC WALL TILE
COLOR: XXX
ITEM # ITEM DESCRIPTION
CT-2 CERAMIC FLOOR TILE
COLOR: XXX
WALL AND FLOOR LEGEND
1. ELEVATION FOR UNISEX TOILET 116 ARE SIMILAR.
2. FOR TOILET ACCESSORIES MOUNTING HEIGHTS AND SCHEDULE
REFER TO OSB-A-003
NOTES:
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
<<PM/DM>>
BRANCH MANAGER
CHIEF ENG/ARCH
<<XX>>
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
As indicated
/2
/2
:0
:1 P
M
OSB-A-403
288102
C R
A N
E
IN
D
IA
N
A
Designer Author Checker
E N
L A
R G
E D
T
O
IL
E T
S
N S
A C
R A
N E
U N
D E
R W
A T
E R
L A
U N
C H
T E
S T
F A
C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C T
F -A
-4
E N
L A
R G
E D
T
O
IL
E T
S
1/2" = 1'-0"C1
TOILET PLANS
1/2" = 1'-0"A1
TOILET REFLECTED CEILING PLANS
1/2" = 1'-0"C3
TOILET ELEVATION
1/2" = 1'-0"C5
TOILET ELEVATION
1/2" = 1'-0"A3
TOILET ELEVATION
1/2" = 1'-0"A5
TOILET ELEVATION
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
O V
E R
T H
E S
H O
U L
D E
R R
E V
IE
W
/2 /2 stmurphy stmurphy
VTD
V T
D
V T
D
A
A.8
D.2
E
E
A
A.8
D.2
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
<<PM/DM>>
BRANCH MANAGER
CHIEF ENG/ARCH
<<XX>>
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
1/4" = 1'-0"
/2
/2
:0
:1 P
M
OSB-A-411
288103
C R
A N
E
IN
D
IA
N
A
XXX
YYY
Author XXX
YYY
E N
L A
R G
E D
A L C
O V
E F
L O
O R
A N
D R
E F
L E
C T
E D
C E
IL
IN
G P
L A
N S
N S
A C
R A
N E
U N
D E
R W
A T
E R
L A
U N
C H
T E
S T
F A
C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C T
F -A
-4
E N
L A
R G
E D
A L C
O V
E F
L O
O R
A N
D R
E F
L E
C T
E D
C E
IL
IN
G P
L A
N S
1/4" = 1'-0"B4
ENLARGED PLAN - ALCOVE 121
1/4" = 1'-0"B3
ENLARGED PLAN - ALCOVE 120
1/4" = 1'-0"B2
ENLARGED PLAN - ALCOVE 119
1/4" = 1'-0"B1
ENLARGED PLAN - ALCOVE 118
1/4" = 1'-0"C1
ENLARGED RCP - ALCOVE 118
1/4" = 1'-0"C4
ENLARGED RCP - ALCOVE 121
1/4" = 1'-0"C3
ENLARGED RCP - ALCOVE 120
1/4" = 1'-0"C2
ENLARGED RCP - ALCOVE 119
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
O V
E R
T H
E S
H O
U L
D E
R R
E V
IE
W
/2 /2 stmurphy stmurphy
BOTTOM OF STRUCTURE/
ROOF PANEL
TYPE 2: SEALANT BOTH SIDES;
TYPE 2F: UL-APPROVED FIRE-RATED
TOP OF WALL JOINT ASSEMBLY
TYPE 2: 5/8" ABUSE-RESISTANT
GYP BD EACH SIDE;
TYPE 2F: TYPE 'X' 5/8" ABUSE-RESISTANT
GYP BD EACH SIDE
LATERAL BRACING @ MID-SPAN
BASE RUNNER WITH
SEALANT BOTH SIDES
FLOOR SLAB
LINE OF SCHEDULE CEILING
6" MTL STUDS, 20 GA, @ 16" OC
DEFLECTION TRACK
2PARTITION TYPES NON-RATED 2F 1-HR RATED, UL # U4191PARTITION TYPES NON-RATED 1F 1-HR RATED, UL # U419
BOTTOM OF STRUCTURE/
ROOF PANEL
TYPE 1: SEALANT BOTH SIDES;
TYPE 1F: UL-APPROVED FIRE-RATED
TOP OF WALL JOINT ASSEMBLY
DEFLECTION TRACK
LATERAL BRACING @ MID-SPAN
SCHEDULED WALL BASE
LINE OF SCHEDULE CEILING
TYPE 1: 5/8" ABUSE-RESISTANT
GYP BD EACH SIDE;
TYPE 1F: TYPE 'X' 5/8" ABUSE-RESISTANT
GYP BD EACH SIDE
BASE RUNNER WITH
SEALANT BOTH SIDES
FLOOR SLAB
3 5/8" MTL STUDS, 20 GA, @ 16" OC
SCHEDULED WALL BASE
STUD BRACING TO STRUCTURE
ABOVE @ 4'-0" OC MAX
ALTERNATING EACH SIDE
M
IN6
3PARTITION TYPE
BATT SOUND ATTENTUATIONBATT SOUND ATTENTUATION
LINE OF SCHEDULE CEILING
5/8" ABUSE-RESISTANT
GYP BD EACH SIDE
BASE RUNNER WITH
SEALANT BOTH SIDES
FLOOR SLAB
3 5/8" MTL STUDS, 20 GA, @ 16" OC
SCHEDULED WALL BASE
BATT SOUND ATTENTUATION
STUD BRACING TO STRUCTURE
ABOVE @ 4'-0" OC MAX
ALTERNATING EACH SIDE
4PARTITION TYPE
LINE OF SCHEDULE CEILING
5/8" ABUSE-RESISTANT
GYP BD
BASE RUNNER WITH
SEALANT BOTH SIDES
FLOOR SLAB
3 5/8" MTL STUDS, 20 GA,
@ 16" OC
SCHEDULED WALL BASE
BOTTOM OF STRUCTURE/
ROOF PANEL
LATERAL BRACING @ MID-SPAN
FLOOR SLAB
LINE OF SCHEDULE CEILING
6" MTL STUDS, 20 GA,
@ 16" OC
DEFLECTION TRACK
BOTTOM OF STRUCTURE/
ROOF PANEL
SEALANT
DEFLECTION TRACK
LATERAL BRACING @ MID-SPAN
SCHEDULED WALL BASE
LINE OF SCHEDULE CEILING,
WHERE SHOWN ON CEILING PLAN
5/8" ABUSE-RESISTANT
GYP BD
BASE RUNNER WITH
SEALANT
FLOOR SLAB
3 5/8" MTL STUDS, 20 GA,
@ 16" OC
SCHEDULED WALL BASE
5PARTITION TYPE 6PARTITION TYPE
SEALANT
M
IN6
5/8" ABUSE-RESISTANT
GYP BD
BASE RUNNER WITH
SEALANT
NOTES:
1. SEE INTERIOR ELEVATIONS FOR CERAMIC WALL TILES AT TOILET ENLARGED PLANS AND ELEVATIONS.
2. USE MOISTURE & MOLD RESISTANT GYPSUM BOARD AS TILE SUBSTRATE, AND ABUSE-RESISTANT
GYPSUM BOARD WHERE EXPOSED IN TOILETS AND JANITOR'S CLOSET.
3. USE 5/8" ABUSE RESISTANT GYPSUM BOARD ON ALL ASSEMBLIES UON.
4. ALL REQUIRED FIRE ASSEMBLIES INCLUDING FIRE DOORS AND DAMPERS, ALONG WITH ALL REQUIRED
HARDWARE, ANCHORAGE, FRAMES AND SILLS, SHALL BE INSTALLED AND MAINTAINED AS SPECIFIED IN THE BUILDING OR FIRE CODE. THESE ASSEMBLIES SHALL BEAR AN APPROVED LABEL SHOWING THE
RATING THEREOF AND SHALL BE PROPERLY INSTALLED.
5. PENETRATIONS THROUGH ALL RATED WALLS, FLOOR/CEILING AND ROOF/CEILING ASSEMBLIES SHALL
BE PROTECTED BY AN APPROVED FIRESTOPPING METHOD AS PER SPECIFICATION. PROVIDE
FIRESTOPPING AS PER THE ENCLOSED DETAILS FOR ALL REQUIRED RATED PENETRATIONS. ALL
FIRESTOPING SHALL MAINTAIN A SINGLE MANUFACTURER THROGHOUT THE PROJECT.
6. SEAL THE PERIMETER OF ALL WALL SYSTEMS WITH A NON-HARDENING SEALANT. SURFACE SHALL BE
CLEAN AND DUST FREE.
7. PROVIDE LABELED GYP BD AT FIRE RATED PARTITIONS.
8. FIRE RATED SEPARATION ASSEMBLIES TO EXTEND TO STRUCTURE ABOVE UON.
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
<<PM/DM>>
BRANCH MANAGER
CHIEF ENG/ARCH
<<XX>>
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
As indicated
/2
/2
:0
:1 P
M
OSB-A-501
288104
C R
A N
E
IN
D
IA
N
A
XXX
YYY
Author XXX
YYY
P A
R T
IT
IO
N T
Y P
E S
N S
A C
R A
N E
U N
D E
R W
A T
E R
L A
U N
C H
T E
S T
F A
C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C T
F -A
-5
P A
R T
IT
IO
N T
Y P
E S
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
O V
E R
T H
E S
H O
U L
D E
R R
E V
IE
W
/2 /2 stmurphy stmurphy
3" INSULATED
METAL WALL PANEL
STRUCTURAL STEEL
EAVE PLATE WELDED
TO RECTANGULAR
STEEL TUBE (SEE
STRUCTURAL DWGS.)
RECTANGULAR
STEEL TUBE
(SEE STRUCTURAL
DWGS.)
INSULATED METAL
WALL PANEL JOINT
NOTCH METAL WALL
PANEL FOR EAVE PLATE
(GAP AROUND PLATE
NOT TO EXCEED 3/8")
EXPANDABLE FOAM
EXPANDABLE FOAM
NOTCH METAL WALL
PANEL FOR EAVE PLATE
(GAP AROUND PLATE
NOT TO EXCEED 3/8")
3" INSULATED
METAL WALL PANEL
INSULATED METAL
WALL PANEL JOINT
STRUCTURAL STEEL
EAVE PLATE WELDED
TO RECTANGULAR
STEEL TUBE (SEE
STRUCTURAL DWGS.)
RECTANGULAR
STEEL TUBE
(SEE STRUCTURAL
DWGS.)
WALL SUPPORT
NEW PENETRANT
(INSTALL THROUGH CUTOUT)
PANEL CUTOUT
(1/2" MINIMUM CLEARANCE
AROUND PENETRANT)
EXPANDABLE FOAM
(NOT BY PANEL
MANUFACTURER)
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
<<PM/DM>>
BRANCH MANAGER
CHIEF ENG/ARCH
<<XX>>
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
As indicated
/2
/2
:0
:1 P
M
OSB-A-531
288105
C R
A N
E
IN
D
IA
N
A
Designer Author Checker
D E
T A
IL
S
N S
A C
R A
N E
U N
D E
R W
A T
E R
L A
U N
C H
T E
S T
F A
C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C T
F -A
-5
D E
T A
IL
S
1/2" = 1'-0"C1
EAVE PLATE PENETRATION DETAIL
1/2" = 1'-0"C3
EAVE PLATE PENETRATION DETAIL @ PANEL JOINT
1 1/2" = 1'-0"A1
NEW PENETRANT IN EXISTING WALL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
O V
E R
T H
E S
H O
U L
D E
R R
E V
IE
W
/2 /2 stmurphy stmurphy
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
<<PM/DM>>
BRANCH MANAGER
CHIEF ENG/ARCH
<<XX>>
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
/2
/2
:0
:2 P
M
OSB-A-601
288106
C R
A N
E
IN
D
IA
N
A
XXX
YYY
Author XXX
YYY
D O
O R
S C
H E
D U
L E
N S
A C
R A
N E
U N
D E
R W
A T
E R
L A
U N
C H
T E
S T
F A
C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C T
F -A
-6
D O
O R
S C
H E
D U
L E
OSB - DOOR SCHEDULE
DOOR
NO. TYPE ROOM NAME
DOOR
FIRE
RATING
FRAME
HARDWARE COMMENTS:
SIZE MATERIAL
FINISH
UNDER
CUT TYPE
MATERIAL
FINISH
DETAILS
WIDTH HEIGHT THICKNESS HEAD JAMB SILL
101 E LTV & CANISTER MAINTENANCE AREA 12' - 0" 16' - 0" 3" STEEL, PAINT - STEEL, PAINT 0"
101A E 16' - 0" 20' - 0" 3" STEEL, PAINT - STEEL, PAINT 0"
101B E 16' - 0" 20' - 0" 3" STEEL, PAINT - STEEL, PAINT 0"
101C B LTV & CANISTER MAINTENANCE AREA 4' - 0" 7' - 0" 1 3/4" HM, PAINT A HM, PAINT 0"
103 C INSTRUMENTATION ROOM 6' - 0" 7' - 0" 1 3/4" HM, PAINT B HM, PAINT 0"
103A A INSTRUMENTATION ROOM 3' - 0" 7' - 0" 1 3/4" HM, PAINT A HM, PAINT 0"
104 C LAUNCH CONTROL CENTER 6' - 0" 7' - 0" 1 3/4" HM, PAINT B HM, PAINT 0"
104A A LAUNCH CONTROL CENTER 3' - 0" 7' - 0" 1 3/4" HM, PAINT A HM, PAINT 0"
105 A LCC EQUIPMENT ROOM 4' - 0" 7' - 0" 1 3/4" HM, PAINT A HM, PAINT 0"
106 A OFFICE 3' - 0" 7' - 0" 1 3/4" HM, PAINT A HM, PAINT 0"
107 B OFFICE 3' - 0" 7' - 0" 1 3/4" HM, PAINT A HM, PAINT 0"
108 B OFFICE 3' - 0" 7' - 0" 1 3/4" HM, PAINT A HM, PAINT 0"
109 A CONFERENCE ROOM 3' - 0" 7' - 0" 1 3/4" HM, PAINT A HM, PAINT 0"
110 C CLOSET 5' - 0" 7' - 0" 1 3/4" HM, PAINT A HM, PAINT 0"
112 A ELECTRICAL ROOM 3' - 0" 7' - 0" 1 3/4" HM, PAINT A HM, PAINT 0"
113 A COMMUNICATIONS ROOM 3' - 0" 7' - 0" 1 3/4" HM, PAINT A HM, PAINT 0"
114 A JAN. CL 3' - 0" 7' - 0" 1 3/4" HM, PAINT A HM, PAINT 0"
115 A UNISEX TLT 3' - 0" 7' - 0" 1 3/4" HM, PAINT A HM, PAINT 0"
116 A UNISEX TLT 3' - 0" 7' - 0" 1 3/4" HM, PAINT A HM, PAINT 0"
118 A WIND ALCOVE 3' - 0" 7' - 0" 1 3/4" HM, PAINT A HM, PAINT 0"
119 A WIND ALCOVE 3' - 0" 7' - 0" 1 3/4" HM, PAINT A HM, PAINT 0"
120 A WIND ALCOVE 3' - 0" 7' - 0" 1 3/4" HM, PAINT A HM, PAINT 0"
121 C WIND ALCOVE 6' - 0" 7' - 0" 1 3/4" HM, PAINT B HM, PAINT 0"
201 A STORAGE 3' - 0" 7' - 0" 1 3/4" HM, PAINT A HM, PAINT 0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
O V
E R
T H
E S
H O
U L
D E
R R
E V
IE
W
/2 /2 stmurphy stmurphy
FIRE ALARM / MASS NOTIFICATION
GENERAL NOTES ACU AUTONOMOUS CONTROL UNIT
AFF ABOVE FINISHED FLOOR
AHJ AUTHORITY HAVING JURISDICTION
AVG AVERAGE
CA CLEAN AGENT
CO CONTRACTING OFFICER
COR CONTRACTING OFFICER REPRESENTATIVE
COTR CONTRACTING OFFICERS TECHNICAL REPRESENTATIVE
ELEV ELEVATION
EOL END OF LINE RESISTOR
FPC FIRE PUMP CONTROLLER
IDC INITIATING DEVICE CIRCUIT
MIN MINIMUM
NAC NOTIFICATION APPLIANCE CIRCUIT
NC NONCOMBUSTIBLE
NIC NOT IN CONTRACT
NP NOT PERMITTED
QFPE QUALIFIED FIRE PROTECTION ENGINEER
SLC SIGNALING LINE CIRCUIT
SQFT SQUARE FEET
WP WEATHER PROOF
GENERAL NOTES SYMBOLS - PANEL ABBREVIATIONS
SYMBOL DESCRIPTION
MONITOR MODULE
SYMBOLS - MISCELLANEOUS
SYMBOL DESCRIPTION
MANUAL PULL STATION
SYMBOLS - INITIATING
(ALL SYMBOLS AND ABBREVIATIONS SHOWN ARE NOT
NECESSARILY USED ON THE DRAWINGS)
CO
S,R
ID
P,I,ASD
SMOKE DETECTOR
P = PHOTOELECTRIC
I = IONIZATION
ASD = AIR SAMPLING DETECTOR
DUCT DETECTOR
ID = FAN UNIT DESIGNATION
S = SUPPLY
R = RETURN
CARBON MONOXIDE DETECTOR
MM
CONTROL MODULECM
C TAMPER SWITCH
C WATER FLOW SWITCH
TS
WF
A. THE FIRE ALARM/MASS NOTIFICATION SYSTEM SHALL BE DESIGNED, INSTALLED, AND
COMMISSIONED IN ACCORDANCE WITH THE FOLLOWING:
• INTERNATIONAL BUILDING CODE (IBC), (2015 EDITION)
• NFPA 72 (2019 EDITION)
• UFC 3-600-01 (CHANGE 2, MARCH 2018)
• UFC 4-021-01 (CHANGE 1, JANUARY 2010)
B. THE CONTRACTOR SHALL RETAIN THE SERVICES OF A QUALIFIED FIRE PROTECTION ENGINEER
(QFPE) AS DEFINED BY UFC 3-600-01. THE QFPE SHALL BE RESPONSIBLE FOR THE DESIGN,
INSPECTION, AND TESTING OF THE FIRE PROTECTION SYSTEMS THROUGHOUT THE BUILDING.
C. THESE DOCUMENTS DEPICT A PERFORMANCE LEVEL ENGINEERING DESIGN LAYOUT TO BE
UTILIZED AS GUIDANCE FOR THE PLANNING OF THE SYSTEM BY THE CONTRACTOR. PROVIDE
COMPLETE DOCUMENTS FOR REVIEW AND APPROVAL FROM THE ENGINEER OF RECORD AND
THE AUTHORITY HAVING JURISDICTION PRIOR TO INSTALLATION. INCLUDE IN THE SHOP
DRAWINGS AND CALCULATIONS ANY ADDITIONAL EQUIPMENT NECESSARY, INCLUDING
INITIATING DEVICES AND NOTIFICATION APPLIANCES, TO PROVIDE A COMPLETE INSTALLATION
AND COMPLY WITH LOCAL CODES, AMENDMENTS AND BASE STANDARDS.
D. FOR COMPLETE SYSTEM CONTROL, REFER TO THE MATRIX OF OPERATIONS WITHIN THIS
PACKAGE.
E. PROVIDE AN ADDRESSABLE FIRE ALARM/MASS NOTIFICATION SYSTEM CONTROL PANEL.
SYSTEM SHALL BE NETWORKED INTO THE EXISTING BASEWIDE FIRE ALARM SYSTEM.
F. FINAL FIRE ALARM/MASS NOTIFICATION SYSTEM TEST SHALL BE WITNESSED BY THE QFPE. FILE
A "RECORD OF COMPLETION" PREPARED IN ACCORDANCE WITH NFPA 72, AND THE FIRE ALARM
TEST REPORT WITH THE AHJ.
G. THE FLASH RATE OF VISIBLE NOTIFICATION APPLIANCES SHALL NOT EXCEED 2 FLASHES PER
SECOND, NOR BE LESS THAN 1 FLASH EVERY SECOND, IN ACCORDANCE WITH NFPA 72. A
MAXIMUM PULSE DURATION SHALL BE 0.2 SECONDS WITH A MAXIMUM DUTY CYCLE OF 40%, IN
ACCORDANCE WITH NFPA 72. VISIBLE NOTIFICATION APPLIANCES SHALL BE SPACED IN
ACCORDANCE WITH NFPA 72. ALL STROBES SHALL BE SYNCHRONIZED.
H. AUDIBLE FIRE ALARM SOUND LEVELS SHALL BE AT LEAST 15 dBA ABOVE THE AVERAGE AMBIENT SOUND LEVEL OR 5 dBA ABOVE THE MAXIMUM SOUND LEVEL HAVING A DURATION OF AT LEAST
60 SECONDS, WHICHEVER IS GREATER, MEASURED 5 FEET ABOVE THE FLOOR IN THE
OCCUPIABLE AREA, BUT NOT GREATER THAN 120 dBA AT THE MINIMUM HEARING DISTANCE
FROM THE AUDILE APPLIANCE. PROVIDE ADEQUATE NOTIFICATION APPLIANCES THROUGHOUT
THE FACILITY TO MEET THE NFPA 72 REQUIREMENTS.
I. SPRINKLER SYSTEM TAMPER AND FLOW SWITCHES SHALL BE INSTALLED UNDER
SPECIFICATION SECTION 21 13 13. CONNECT DEVICES TO THE FIRE ALARM SIGNALING LINE
CIRCUITS.
J. OBTAIN APPROVALS FROM THE AHJ PRIOR TO COMMENCING WORK.
K. DO NOT LOCATE DETECTORS IN DIRECT AIR OR CLOSER THAN 3 FEET FROM AN AIR SUPPLY OR
RETURN DIFFUSER.
L. MOUNT ALL WALL-MOUNTED VISUAL AND VISUAL/AUDIBLE NOTIFICATION APPLIANCES WITH THE
ENTIRE STROBE LENS BETWEEN 80" TO 96" ABOVE THE FINISHED FLOOR.
M. FIRE ALARM SIGNALING LINE CIRCUITS (SLC) AND NOTIFICATION APPLIANCE CIRCUITS (NAC) ARE
TO BE CLASS B. T-TAPS AND WIRE NUTS ARE NOT PERMITTED.
SYMBOL DESCRIPTION
FMCP FIRE ALARM / MASS NOTIFICATION CONTROL PANEL
ANN ANNUNCIATOR PANEL
LOCAL OPERATING CONSOLE
NOTIFICATION APPLIANCE CONTROL PANEL
LOC
NAC
F
KNOX BOX (WITH TAMPER SWITCH)KB
VTD
SYMBOL DESCRIPTION
FIRE ALARM / MASS NOTIFICATION
SPEAKER/STROBE (CEILING-MOUNTED, UNLESS OTHERWISE
NOTED)
CD = CANDELA RATING
SYMBOLS - NOTIFICATION
#CD
SPEAKER (WALL-MOUNTED, UNLESS OTHERWISE NOTED)
WP = WEATHER PROOF
WP
FIRE ALARM / MASS NOTIFICATION
STROBE (CEILING-MOUNTED, UNLESS OTHERWISE NOTED)
CD = CANDELA RATING
#CD
FIRE ALARM / MASS NOTIFICATION STROBE
(WALL-MOUNTED, UNLESS OTHERWISE NOTED)
CD = CANDELA RATING
FIRE ALARM / MASS NOTIFICATION SPEAKER/STROBE
(WALL-MOUNTED, UNLESS OTHERWISE NOTED)
CD = CANDELA RATING
SPEAKER (CEILING-MOUNTED, UNLESS OTHERWISE NOTED)
WP = WEATHER PROOFWP
VISUAL TEXT DISPLAY
#CD
#CD
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
<<PM/DM>>
BRANCH MANAGER
CHIEF ENG/ARCH
<<XX>>
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
NTS
/2
/2
:2
:1
A
M
OSB-FA001
288107
C R
A N
E
IN
D
IA
N
A
MFO MFO JCM
F
IR
E A
L A
R M
A N
D M
A S
S N
O T
IF
IC
A T
IO
N
G E
N E
R A
L N
O T
E S
S
Y M
B O
L S
A
N D
A B
B R
E V
IA
T
IO
N
S
N S
A C
R A
N E
U N
D E
R W
A T
E R
L A
U N
C H
T E
S T
F A
C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C T
F -F
A
F
IR
E
A L
A R
M A
N D
M A
S S
N O
T
IF
IC
A
T
IO
N G
E N
E R
A L
N O
T E
S S
Y M
B O
L S
A
N D
A B
B R
E V
IA
T
IO
N
S
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
O V
E R
T H
E S
H O
U L
D E
R R
E V
IE
W
/2 /2 stmurphy stmurphy
F V
T D
V T
D F
F M
C P
C
WF
C
TS
MM MM
VTD
15 30
15 15
F
L O
C
GENERAL NOTES
1. REFER TO SHEET FA-001 FOR FIRE ALARM AND MASS
NOTIFICATION GENERAL NOTES, SYMBOLS, AND
ABBREVIATIONS.
2. REFER TO ARCHITECTURAL REFLECTED CEILING
PLANS FOR COORDINATION WITH LIGHTS,
MECHANICAL DIFFUSERS, AND CEILING GRID.
KEY NOTES
XXX
XXX
7654321
A
B
C
D
E
A.8
D.2
(3)
ELECTRICAL ROOM
COMMUNICATIONS
ROOM
JAN. CL
UNISEX TLT
LOCKABLE TOOL CRIB
LCC EQUIPMENT
ROOM
CONFERENCE ROOM
INSTRUMENTATION
ROOM
OFFICE
OFFICE
OFFICE
CLOSET
BREAK ROOM
LAUNCH CONTROL
CENTER
UNISEX TLT
LTV & CANISTER
MAINTENANCE AREA
CORRIDOR
A
B
C
A.8
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
<<PM/DM>>
BRANCH MANAGER
CHIEF ENG/ARCH
<<XX>>
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
As indicated
/2
/2
:2
:1
A
M
OSB-FA101
288108
C R
A N
E
IN
D
IA
N
A
MFO MFO JCM
F
IR
E A
L A
R M
A N
D M
A S
S N
O T
IF
IC
A T
IO
N
F
IR
S T
F L O
O R
P L A
N
N S
A C
R A
N E
U N
D E
R W
A T
E R
L A
U N
C H
T E
S T
F A
C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C T
F -F
A
F
IR
E
A L
A R
M A
N D
M A
S S
N O
T
IF
IC
A
T
IO
N F
IR
S
T F
L O
O R
P L A
N
1/8" = 1'-0"A1
FIRE ALARM AND MASS NOTIFICATION
FIRST FLOOR PLAN
1/8" = 1'-0"C1
FIRE ALARM AND MASS NOTIFICATION
SECOND FLOOR PLAN
8'4' 16'0
SCALE: 1/8"=1'-0"
8'4' 16'0
SCALE: 1/8"=1'-0"
PLAN NORTH
PLAN NORTH
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
O V
E R
T H
E S
H O
U L
D E
R R
E V
IE
W
/2 /2 stmurphy stmurphy
CONDUIT FROM
PREVIOUS DEVICES
CONDUIT TO
REMAINING DEVICES
FIRE ALARM NOTIFICATION
APPLIANCE LOCATION ZONE
(AUDIBLE ONLY APPLIANCES
SHALL BE MOUNTED NOT LESS
THAN 90" AFF AND NOT LESSTHAN
6" BELOW THE FINISHED CEILING)
FINISHED FLOOR
FINISHED CEILING
(WHERE PROVIDED)
A F
F
A F
F
A F
FFIRE
SIGNALING LINE AND
NOTIFICATION APPLIANCE
CIRCUIT CONDUIT
(SINGLE CONDUIT, WHEN
PERMITTED BY MANUFACTURER)
MAXIMUM HORIZONTAL
DISTANCE TO EXIT IS 5
FEET
MOUNTED PULL
STATION AND
BACKBOX
JUNCTION BOX
DETECTOR BASE
SMOKE
EXPOSED CEILING
DETECTOR
J-BOX ON
3/4" EMT CONDUIT
SMOKE
MEMBER
STRUCTURAL
FIRST FLOOR
FMCP
BATT
120V POWER
FIRST FLOOR
ADD NEW CIRCUITS AS
NECESSARY.
WP
BASEWIDE FIRE ALARM
REPORTING SYSTEM
NAC - CLASS A
SPEAKER
NAC - CLASS A
STROBE - FA
SLC
CLASS A
NOTE: RISER DIAGRAM IS A SCHEMATIC REPRESENTATION OF THE FIRE
ALARM/MASS NOTIFICATION SYSTEM. REFER TO THE FIRE ALARM/MASS
NOTIFICATION PLANS FOR LOCATIONS AND QUANTITIES OF DEVICES AND
APPLIANCES.
SLC
CLASS A
SLC
CLASS A
(PIV)
TSWF
SPEAKERS
CLASS A
SLC
CLASS A
120V
POWER
MM
CM F
NAC
LOCANN
SS
SS
MM
MM
MM
S
P
BASEWIDE MASS
NOTIFICATION SYSTEM
VTD VTD VTD VTD RETURN TO
PANEL
DROP CEILING TILE
DETECTOR BASE
SMOKE
4"x4"x2-1/8" J-BOX
J-BOX ON FLOOR SLAB
SMOKE DETECTOR
1/2" FLEX WITH FIRE
DETECTION CIRCUITS
"T" BAR TYPE HANGER
3/4" EMT CONDUIT
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
<<PM/DM>>
BRANCH MANAGER
CHIEF ENG/ARCH
<<XX>>
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
NOT TO SCALE
/2
/2
:2
:2
A
M
OSB-FA501
288109
C R
A N
E
IN
D
IA
N
A
MFO MFO JCM
F
IR
E A
L A
R M
A N
D M
A S
S N
O T
IF
IC
A T
IO
N
D E
T A
IL
S
N S
A C
R A
N E
U N
D E
R W
A T
E R
L A
U N
C H
T E
S T
F A
C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C T
F -F
A
F
IR
E
A L
A R
M A
N D
M A
S S
N O
T
IF
IC
A
T
IO
N D
E T
A
IL
S
NTSB1
FIRE ALARM MOUNTING DETAIL
NTSC3
EXPOSED CEILING DETECTOR DETAIL
NTSA3
FIRE ALARM / MASS NOTIFICATION RISER
DIAGRAM
NOT TO SCALEA1
SUSPENDED CEILING DETECTOR DETAIL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
O V
E R
T H
E S
H O
U L
D E
R R
E V
IE
W
/2 /2 stmurphy stmurphy
CONTROL UNIT
ANNUNCIATION NOTIFICATION
LIFE SAFETY
CONTROL
B U
IL
D
IN
G
F A
C P
A L A
R M
L E
D A
N D
A U
D
IB
L E
S
IG
N A
L
B U
IL
D
IN
G
F A
C P
S U
P E
R V
IS
O
R Y
L E
D A
N D
A U
D
IB
L E
S
IG
N A
L
B U
IL
D
IN
G
F A
C P
T R
O U
B L E
L E
D A
N D
A U
D
IB
L E
S
IG
N A
L
D
IS
P L A
Y O
N A
N N
U N
C
IA
T O
R
R E
P O
R T A
L A
R M
S
IG
N A
L T
O B
A S
E C
E N
T R
A L S
T A
T
IO
N M
O N
IT
O
R
IN
G S
T A
T
IO
R E
P O
R T S
U P
E R
V
IS
O R
Y S
IG
N
A L T
O B
A S
E C
E N
T R
A L M
O N
IT
O
R
IN
G S
T A
T
IO
N
R E
P O
R T T
R O
U B
L E
S
IG
N A
L T
O B
A S
E C
E N
T R
A L M
O N
IT
O
R
IN
G S
T A
T
IO
N
A C
T
IV
A T E
F
IR
E A
L A
R M
A U
D
IB
L E
A N
D V
IS
U
A L N
O T
IF
IC
A
T
IO
N A
P P
L
IA
N C
E S
W
IT
H
IN
B U
IL
D
IN
G
D E
L
IV
E R
M A
S S
N O
T
IF
IC
A
T
IO
N L
IV
E
M E
S S
A G
E
D E
L
IV
E R
M A
S S
N O
T
IF
IC
A
T
IO
N P
R E
-R E
C O
R D
E D
M E
S S
A G
E
SYSTEM OUTPUTS
MANUAL FIRE ALARM PULL STATION
SYSTEM INPUT
AREA SMOKE DETECTOR2
A B C D E F G H I J K L M N O P Q R S T U
A B C D E F G H I J K L M N O P Q R S T U
A C
T
IV
A T E
M A
S S
N O
T
IF
IC
A
T
IO
N A
U D
IB
L E
A N
D V
IS
U
A L N
O T
IF
IC
A
T
IO
N A
P P
L
IA
N C
E S
W
IT
H
IN
B U
IL
D
IN
G
INDICATES ACTION WILL CAUSE A SPECIFIC RESULT
EMPTY SQUARE INDICATES ACTION WILL NOT CAUSE A SPECIFIC RESULT
V
V W
W
D E
A C
T
IV
A T E
P U
B L
IC
A D
D R
E S
S S
Y S
T E
M
D E
A C
T
IV
A T E
F
IR
E A
L A
R M
A U
D
IB
L E
A N
D V
IS
U
A L N
O T
IF
IC
A
T
IO
N A
P P
L
IA
N C
E S
W
IT
H
IN
B U
IL
D
IN
G
SECURE AREA TEMPERATURE SENSORS
MASS NOTIFICATION SYSTEM DISABLING SWITCH
DUCT SMOKE DETECTOR
WATER FLOW SWITCH
VALVE TAMPER SWITCH
OPERATION OF MASS NOTIFICATION SYSTEM - LIVE MESSAGES
OPERATION OF MASS NOTIFICATION SYSTEM - PRE-RECORDED MESSAGES
HVAC MASTER SHUTDOWN SWITCH
PANEL AC POWER FAIL
PANEL LOW BATTERY
OPEN CIRCUIT
GROUND FAULT
SHORT CIRCUIT
12 PANEL TROUBLE
S H
U T D
O W
N A
L L H
V A
C U
N
IT
S A
N D
E X
H A
U S
T F
A N
S
S H
U T D
O W
N A
S S
O C
IA
T E
D H
V A
C U
N
IT
18 ---
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
<<PM/DM>>
BRANCH MANAGER
CHIEF ENG/ARCH
<<XX>>
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
NTS
/2
/2
:2
:2
A
M
OSB-FA502
288110
C R
A N
E
IN
D
IA
N
A
MFO MFO JCM
F
IR
E A
L A
R M
A N
D M
A S
S N
O T
IF
IC
A T
IO
N
M A
T R
IX
O
F O
P E
R A
T
IO
N S
N S
A C
R A
N E
U N
D E
R W
A T
E R
L A
U N
C H
T E
S T
F A
C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C T
F -F
A
F
IR
E
A L
A R
M A
N D
M A
S S
N O
T
IF
IC
A
T
IO
N M
A T
R
IX
O F
O P
E R
A T
IO
N
S
NTSA1
FIRE ALARM AND MASS NOTIFICATION
MATRIX OF OPERATIONS
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
O V
E R
T H
E S
H O
U L
D E
R R
E V
IE
W
/2 /2 stmurphy stmurphy
GENERAL NOTES AND SYMBOLS
PIPING SYMBOLS
FIRE SPRINKLER SYMBOLS
DIRECTION OF SLOPE DOWN
PRESSURE CONTROL VALVE
TEST PORT
RELIEF VALVE
GATE VALVE
CHECK VALVE
ECCENTRIC REDUCER
TEE OUTLET DOWN
TEE OUTLET UP
CONCENTRIC REDUCER
UNION
FIRE SPRINKLER NOTES
ELBOW DOWN
VALVE IN DROP
VALVE IN CENTER DROP
VALVE IN RISE
(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)
DIRECTION OF FLOW
ELBOW UP
A. PROVIDE COMPLETE WET PIPE FIRE SPRINKLER SYSTEMS FOR
THE ENTIRE BUILDING DESIGNED AND INSTALLED IN
ACCORDANCE WITH UFC 3-600-01 WITH CHANGE 2 (2018
EDITION), IBC (2015 EDITION), AND NFPA 13 (2019 EDITION).
B. THE CONTRACTOR SHALL RETAIN THE SERVICES OF A
QUALIFIED FIRE PROTECTION ENGINEER (QFPE) AS DEFINED BY
UFC 3-600-01. THE QFPE SHALL BE RESPONSIBLE FOR THE
DESIGN, INSPECTION, AND TESTING OF THE FIRE PROTECTION
SYSTEMS THROUGHOUT THE BUILDING.
C. VERIFY ALL LOCATIONS AND MEASUREMENTS AS CONDITIONS
MAY VARY THROUGHOUT CONSTRUCTION. ALL CHANGES FROM
THE ORIGINAL DESIGN MUST BE APPROVED BY THE QFPE.
D. SPRINKLER CONTRACTOR SHALL INSTALL TAMPER AND FLOW
SWITCHES. CONNECTIONS TO THE FIRE ALARM SYSTEM'S
SIGNALING LINE CIRCUIT SHALL BE MADE UNDER
SPECIFICATION DIVISION 28.
E. SPRINKLER CONTRACTOR SHALL UTILIZE FLOW DATA
PROVIDED TO BASE HYDRAULIC CALCULATIONS AND SIZE
PIPING. IF THE TEST RESULTS ARE OVER ONE YEAR OLD,
SPRINKLER CONTRACTOR TO PERFORM A NEW HYDRANT FLOW
TEST.
F. CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AND
APPROVALS FROM THE AHJ PRIOR TO COMMENCING WORK.
G. HYDRAULICALLY CALCULATE THE WET PIPE SPRINKLER
SYSTEMS PER NFPA 13 DENSITY AND SPACING LISTED IN THE
SPRINKLER DESIGN CRITERIA TABLE BELOW. FIELD VERIFY
SYSTEM DESIGN AND LAYOUT PRIOR TO FABRICATION OR
INSTALLATION.
H. PROVIDE PIPE HANGERS ON ALL FIRE SPRINKLER SYSTEM
PIPING AND EQUIPMENT PER NFPA 13.
I. SEE ARCHITECTURAL DRAWINGS FOR ROOM FINISH SCHEDULE
AND ROOM USE. SEE ARCHITECTURAL, ELECTRICAL,
MECHANICAL, AND TELECOMMUNICATIONS PLANS FOR THE
LOCATION OF ALL CEILING-MOUNTED DEVICES. FIELD VERIFY
AND COORDINATE THE LOCATIONS OF ALL SYSTEM
COMPONENTS INCLUDING PIPING, ALARMS, DRAINS, TEST
POINTS, ETC. WITH ARCHITECTURAL, STRUCTURAL,
MECHANICAL, AND ELECTRICAL EQUIPMENT WITHIN THE
BUILDING.
J. PROVIDE AUXILIARY DRAINAGE WITH A DRAIN VALVE AND PLUG
FOR ALL TRAPPED SECTION OF PIPE, AS REQUIRED BY NFPA 13.
K. THESE DOCUMENTS DEPICT PERFORMANCE LEVEL
ENGINEERING DESIGN CRITERIA TO BE UTILIZED AS GUIDANCE
FOR THE PLANNING OF THE FIRE SPRINKLER SYSTEM BY THE
CONTRACTOR. PROVIDE COMPLETE DOCUMENTS FOR REVIEW
AND APPROVAL FROM THE ENGINEER OF RECORD AND AHJ
PRIOR TO INSTALLATION. INCLUDE IN THE SHOP DRAWINGS
AND CALCULATIONS ANY ADDITIONAL EQUIPMENT NECESSARY
TO PROVIDE A COMPLETE INSTALLATION.
L. PIPE MAIN DRAIN TO OUTSIDE OF BUILDING. PROVIDE SPLASH
BLOCK AS NECESSARY.
PRESSURE
GAUGE WITH
GAUGE COCK
STRAINER WITH
BLOWDOWN VALVE
SPRINKLER DESIGN CRITERIA
HAZARD
CLASSIFICATION
DENSITY
REQUIREMENTS
DURATION
OF
SUPPLY
MAXIMUM
SPRINKLER
PROTECTION AREA
SPRINKLER
TEMPERATURE
SYSTEM RISER
WATERFLOW TEST DATA
TEST DATE: JANUARY 24, 2019
STATIC PRESSURE: 106 PSI
RESIDUAL PRESSURE: 85 PSI
1454 GPMDISCHARGE FLOW:
ABBREVIATIONS
AFF ABOVE FINISHED FLOOR
AHJ AUTHORITY HAVING JURISDICTION
AVG AVERAGE
BFP DOUBLE CHECK BACKFLOW PREVENTER
CFM CUBIC FEET PER MINUTE
CO CONTRACTING OFFICER
COTR CONTRACTING OFFICER'S TECHNICAL REPRESENTATIVE
ELEV ELEVATION
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FHV FIRE HOSE VALVE
FP FIRE PUMP
FPC FIRE PUMP CONTROLLER
FVC FIRE VALVE CABINET
GALS GALLONS
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GV GATE VALVE
JP JOCKEY PUMP
MIN MINIMUM
NC NONCOMBUSTIBLE
NIC NOT IN CONTRACT
NP NOT PERMITTED
OS&Y OUTSIDE SCREW & YOKE
PSIG POUNDS PER SQUARE INCH GAUGE
SOV SOLENOID VALVE
SQFT SQUARE FEET
UH UNIT HEATER
VLV VALVE
FLOW SWITCH
HOSE
ALLOWANCE
60 MIN.
ORDINARY
0.20 GPM/SQFT OVER
MOST REMOTE 2500 SQFT
130 SQFT ORDINARY 250 GPM
GAUGE HYDRANT # AND LOCATION: GAUGE HYDRANT #1124
FLOW HYDRANT #1201FLOW HYDRANT # AND LOCATION:
K-FACTOR
8.0
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
<<PM/DM>>
BRANCH MANAGER
CHIEF ENG/ARCH
<<XX>>
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
NTS
/2
/2
:2
:2
A
M
OSB-FX001
288111
C R
A N
E
IN
D
IA
N
A
MFO MFO JCM
F
IR
E S
U P
P R
E S
S
IO
N G
E N
E R
A L N
O T
E S
S
Y M
B O
L S
A
N D
A B
B R
E V
IA
T
IO
N
S
N S
A C
R A
N E
U N
D E
R W
A T
E R
L A
U N
C H
T E
S T
F A
C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C T
F -F
X
F
IR
E
S U
P P
R E
S S
IO
N
G E
N E
R A
L N
O T
E S
S
Y M
B O
L S
A
N D
A B
B R
E V
IA
T
IO
N
S
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
O V
E R
T H
E S
H O
U L
D E
R R
E V
IE
W
/2 /2 stmurphy stmurphy
GENERAL NOTES
1. REFER TO SHEET FX-001 FOR FIRE SUPPRESSION
GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS.
2. WET-PIPE SPRINKLER COVERAGE IS PROVIDED
UNLESS NOTED OTHERWISE.
3. ALL AREAS ARE CONSIDERED ORDINARY HAZARD.
KEY NOTES
XXX
XXX
7654321
A
B
C
D
E
A.8
D.2
ELECTRICAL ROOM
COMMUNICATIONS
ROOM
JAN. CL
UNISEX TLT
LOCKABLE TOOL CRIB
LCC EQUIPMENT
ROOM
CONFERENCE ROOM
INSTRUMENTATION
ROOM
OFFICE
OFFICE
OFFICE
CLOSET
BREAK ROOM
LAUNCH CONTROL
CENTER
UNISEX TLT
LTV & CANISTER
MAINTENANCE AREA
CORRIDOR
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
<<PM/DM>>
BRANCH MANAGER
CHIEF ENG/ARCH
<<XX>>
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
As indicated
/2
/2
:2
:2
A
M
OSB-FX101
288112
C R
A N
E
IN
D
IA
N
A
MFO MFO JCM
F
IR
E S
U P
P R
E S
S
IO
N F
IR
S
T F
L O
O R
P L A
N
N S
A C
R A
N E
U N
D E
R W
A T
E R
L A
U N
C H
T E
S T
F A
C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C T
F -F
X
F
IR
E
S U
P P
R E
S S
IO
N
F
IR
S T
F L
O O
R P
L A
N
1/8" = 1'-0"A1
FIRE SUPPRESSION FIRST FLOOR PLAN
PLAN NORTH
8'4' 16'0
SCALE: 1/8"=1'-0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
O V
E R
T H
E S
H O
U L
D E
R R
E V
IE
W
/2 /2 stmurphy stmurphy
RETAINER
ALL THREAD
PIPE RING
ROD
WITH LOCKNUT
BEAM CLAMP
STRAP
MEMBER
STRUCTURAL
SUPPLY (REF CIVIL)
DUCTILE IRON
RESTRAINED JOINT
FLANGE
AND
SPIGOT
PIECE
ESCUTCHEON AT
EXPOSED
LOCATIONS
SEALANT
VERTICAL
RESTRAINED
JOINT
HORIZONTAL
RESTRAINED
JOINT
BUILDING
FLOOR
TO FIRE
PROTECTION
SYSTEMS
THRUST BLOCK
5' - 0"
ARM OVER SHALL MEET
NFPA 13 CRITERIA
SPRINKLER MAIN
OR BRANCH LINE
PENDENT
SPRINKLER
SUSPENDED CEILING
CONCEALED
SPRINKLER
KEY NOTES
DOUBLE CHECK BACKFLOW PREVENTER
GATE VALVE
CHECK VALVE
WATER FLOW INDICATOR
FIRE DEPARTMENT CONNECTION
BFP TEST HEADER
5 2
3 4
TO DRAIN
TO SYSTEM
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
<<PM/DM>>
BRANCH MANAGER
CHIEF ENG/ARCH
<<XX>>
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
As indicated
/2
/2
:2
:2
A
M
OSB-FX501
288113
C R
A N
E
IN
D
IA
N
A
MFO MFO JCM
F
IR
E S
U P
P R
E S
S
IO
N D
E T
A
IL
S
N S
A C
R A
N E
U N
D E
R W
A T
E R
L A
U N
C H
T E
S T
F A
C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C T
F -F
X
F
IR
E
S U
P P
R E
S S
IO
N
D E
T A
IL
S
NTSC1
BEAM CLAMP HANGER DETAIL
NTSC2
FIRE WATER SERVICE DETAIL
NTSA1
SPRINKLER ARM OVER DETAIL (TYPICAL)
NTSB1
CONCEALED SPRINKLER DETAIL
NTSB4
FIRE SUPPRESSION RISER SCHEMATIC
DIAGRAM
A3
RISER 3D ISOMETRIC VIEW
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
O V
E R
T H
E S
H O
U L
D E
R R
E V
IE
W
/2 /2 stmurphy stmurphy
XX
PLUMBING ABBREVIATIONS PLUMBING LEGEND AND SYMBOLS
SPECIAL INSPECTIONS
SYMBOL ABBREVIATION DESCRIPTION
PLUGGED PIPE/OUTLET
CONCENTRIC REDUCER
ECCENTRIC REDUCER
CAPPED PIPE/OUTLET
UNION
P/TRV
U
PRESSURE/TEMPERATURE RELIEF VALVE
HB/WH
SOV
FLEXIBLE PIPE CONNECTOR
HOSE BIBB / WALL HYDRANT
ANCHOR
WATER HAMMER ARRESTER
FLUID FLOW DIRECTION
WHA
GAS COCK
DOMESTIC HOT WATER RETURN LINEDHWR
THERMOMETER
NOTE: NOT ALL ABBREVIATIONS AND
SYMBOLS SHOWN HEREIN ARE UTILIZED.
CHECK VALVECV
TOP CONNECTION
BOTTOM CONNECTION
CO OR WCO CLEANOUT OR WALL CLEANOUT
FCO FLOOR CLEANOUT
COTG CLEANOUT TO GRADE
SHUT-OFF VALVE OR ISOLATION VALVE
BALANCING VALVE
PIPE UP OR DOWN BASED ON SYSTEM
PIPE ELBOW UP OR DOWN BASED ON SYSTEM FLOW
ABS ACRYLONITRILE BUTADIENE STYRENE
ABV ABOVE
AC AIR COMPRESSOR
ADA AMERICAN WITH DISABILITIES ACT
ADJ ADJUSTABLE
AD ACCESS DOOR
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SURFACE
AHU AIR HANDLING UNIT
AMP AMPERE(S)
AP ACCESS PANEL
APPROX APPROXIMATE
ARCH ARCHITECT, ARCHITECTURAL
AS AIR SEPARATOR
ASHRAE AMERICAN SOCIETY OF HEATING,
REFRIGERATION, AND AIR
CONDITIONING ENGINEERS.
AUX AUXILIARY
AV AIR VENT
BFF BELOW FINISHED FLOOR
BFP BACKFLOW PREVENTER
BFV BUTTERFLY VALVE
BHP BRAKE HORSEPOWER
BLDG BUILDING
BOP, B.O.P. BOTTOM OF PIPE
BOS BOTTOM OF STEEL
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
BV BALL VALVE
BWV BACK WATER VALVE
CA COMPRESSED AIR
CAP. CAPACITY
CBV CALIBRATED BALANCE VALVE
CD CONDENSATE DRAIN
CDF CONDENSATE DRAIN FUNNEL
CDP CONDENSATE DRAIN PUMP
CF CUBIC FEET
CFH CUBIC FEET PER HOUR
CH CHILLER
CI CAST IRON
CIRC CIRCULATING
CLG CEILING
CMU CONCRETE MASONRY UNIT
CO CLEANOUT
COL COLUMN
COND CONDENSATE
CONN CONNECT, CONNECTION
CONT CONTINUE, CONTINUATION
COTG CLEANOUT TO GRADE
CP CIRCULATING PUMP
CR CONDENSATE RECEIVER
CU CONDENSING UNIT
CV CHECK VALVE
°C DEGREES CELSIUS
DCW DOMESTIC COLD WATER
DEG DEGREE(S)
DFU DRAINAGE FIXTURE UNIT
DWH DOMESTIC HOT WATER (SUPPLY)
DWHR DOMESTIC HOT WATER RETURN
DIA OR Ø DIAMETER
DIM DIMENSION
DISC DISCONNECT
DISCH DISCHARGE
DIST DISTANCE
DN DOWN
DS DOWNSPOUT
DWG(S) DRAWING(S)
DWH DOMESTIC WATER HEATER
E EXISTING
EA EACH
EER ENERGY EFFICIENCY RATIO
EEW EMERGENCY EYEWASH
EFF EFFICIENCY
ELEV, EL ELEVATION
ELEC ELECTRICAL
ENCL ENCLOSURE
EQ EQUAL
EQUIP EQUIPMENT
EQV EARTHQUAKE VALVE
ESE EMERGENCY SHOWER/EYEWASH
ET EXPANSION TANK
EXT EXTERNAL
EWC ELECTRIC WATER COOLER
SANITARY SEWER/WASTE
EXPANSION JOINT
SQUARE FLOOR DRAIN OR SHOWER DRAIN
FLOOR SINK
KITCHEN EQUIPMENT TAG
BALL VALVE
DCW DOMESTIC COLD WATER SUPPLY
EQUIPMENT CALL OUT
DHW DOMESTIC HOT WATER SUPPLY
SANITARY SEWER/WASTE BELOW FLOOR/GRADE
NATURAL GASGASG
SS
WHEN THE CONTRACTOR IS REQUIRED BY THE GOVERNMENT TO PROVIDE SPECIAL INSPECTIONS AS PART OF THE WORK, THE CONTRACTOR SHALL RETAIN THIRD-PARTY QUALITY ASSURANCE AGENCIES TO CONDUCT THE SPECIAL INSPECTIONS REQUIRED BY THE IBC. THESE INSPECTIONS SHALL BE PERFORMED IN ACCORDANCE WITH THE ICC IBC 2018 AND THE DESIGN DOCUMENTS. THE INSPECTING AGENCY SHALL PROVIDE REPORTS OF THE SPECIAL INSPECTIONS DIRECTLY TO THE GOVERNMENT. REFER TO SPECIAL
INSPECTIONS SPECIFICATION SECTIONS FOR DEFINITIONS AND ADDITIONAL REQUIREMENTS.
GREASE WASTE
1. PROVIDE LABOR AND MATERIALS TO DELIVER COMPLETE AND PROPERLY FUNCTIONING PLUMBING SYSTEMS.
2. INSTALL PLUMBING WORK IN ACCORDANCE WITH CONTRACT SPECIFICATIONS, IPC 2018, UFC REQUIREMENTS, AND APPLICABLE LOCAL
CODES.
3. COORDINATE PLUMBING WORK WITH SITE CONDITIONS AND WORK OF OTHER TRADES. VERIFY SLOPES AND INVERT ELEVATIONS
PRIOR TO COMMENCEMENT OF WORK.
4. FURNISH MATERIALS, CUTTING, PATCHING, ADAPTING AND OTHER INCIDENTAL WORK, TOGETHER WITH SUCH TEMPORARY
CONNECTIONS AS MAY BE REQUIRED.
5. PROVIDE PIPE PENETRATIONS THROUGH FLOOR SLAB AND WALLS WITH PIPE SLEEVES.
6. PROVIDE ACCESS PANELS FOR VALVES, WATER HAMMER ARRESTERS AND OTHER PLUMBING SPECIALTIES LOCATED INSIDE CHASES, BEHIND WALLS OR ABOVE INACCESSIBLE CEILING. COORDINATE EXACT LOCATIONS AND FINISHES OF ACCESS PANELS WITH
ARCHITECTURAL DRAWINGS.
7. PROVIDE SECONDARY STRUCTURAL STEEL MEMBERS FOR PIPING AND EQUIPMENT SUPPORTS. PROVIDE BOLTING AND WELDING OF SUPPORTS PER CONTRACT STRUCTURAL SPECIFICATIONS. SUBMIT SHOP DRAWINGS FOR GOVERNMENT APPROVAL.
8. VENT ROOF PENETRATIONS SHALL BE A MINIMUM OF 15 FT. HORIZONTALLY AWAY FROM THE ROOF EDGE AND AIR INTAKES.
9. PROVIDE FIRE STOPPING FOR PIPING CROSSING FIRE-RATED BARRIERS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED
BARRIER LOCATIONS.
10. MOUNT ALL OVERHEAD UTILITIES AND OTHER FIXTURES WEIGHING 31 POUNDS OR MORE (EXCLUDING DISTRIBUTED SYSTEMS SUCH AS PIPING NETWORKS THAT COLLECTIVELY EXCEED THAT WEIGHT) TO MINIMIZE THE LIKELIHOOD THAT THEY WILL FALL AND INJURE BUILDING OCCUPANTS. DESIGN ALL EQUIPMENT MOUNTINGS TO RESIST FORCES OF 0.5 TIMES THE EQUIPMENT WEIGHT IN ANY HORIZONTAL DIRECTION AND 1.5 TIMES THE EQUIPMENT WEIGHT IN THE DOWNWARD DIRECTION. THIS STANDARD DOES NOT PRECLUDE THE NEED TO DESIGN EQUIPMENT MOUNTINGS FOR FORCES REQUIRED BY OTHER CRITERIA SUCH AS SEISMIC
STANDARDS.
VENT
SS
GW
GW GREASE WASTE BELOW FLOOR/GRADE
KEYED NOTEXX
ROUND FLOOR DRAIN OR SHOWER DRAIN
GPR GAS PRESSURE REGULATOR
PUMP DISCHARGEPD
R RADON
V
FC FAN COIL
FCO FLOOR CLEANOUT
FCW FILTERED COLD WATER
FD FLOOR DRAIN
FFE, F.F.E. FINISH FLOOR ELEVATION
FIN FLR ELEV
FGE, F.G.E. FINISH GRADE ELEVATION
FIN GRADE ELEV
FIN FINISH
FLA FULL LOAD AMPS
FLR FLOOR
FP FIRE PROTECTION
FS FLOOR SINK
FWD FOOD WASTE DISPOSER
G NATURAL GAS
GA GAUGE, GAGE
GALV GALVANIZED
GPR GAS PRESSURE REGULATOR
GW GREASE WASTE
H HEIGHT
HB HOSE BIBB
HD HEAD
HORIZ HORIZONTAL
HP HORSEPOWER
HR HOSE REEL
HVAC HEATING, VENTILATING, AND AIR
CONDITIONING
HZ HERTZ
ID INSIDE DIAMETER
IE, I.E. INVERT ELEVATION
IT INFORMATION TECHNOLOGY
J JOULE
K KELVIN
kCAL/HR KILOCALORIES PER HOUR kG KILOGRAM kG/SQ CM KILOGRAM PER SQUARE CENTIMETER kG/SM KILOGRAM PER SQUARE METER kJ KILOJOULE kPa KILO PASCAL kV COEFFICIENT, VALVE FLOW (METRIC)
L LITERS
LAV LAVATORY
LAT LEAVING AIR TEMPERATURE
LG LENGTH
LH LATENT HEAT
LL LIQUID LINE
LPM LITERS PER METER
LPD LITERS PER DAY
LPH LITERS PER HOUR
LPS LITERS PER SECOND
LWT LEAVING WATER TEMPERATURE
M or m METERS
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MM or mm MILLIMETERS
MPH METERS PER HOUR
MPS METERS PER SECOND
MSB MOP SINK BASIN
MTD MOUNTED
MV MIXING VALVE
N/A NOT APPLICABLE
NC NORMALLY CLOSED
NEMA NATIONAL ELECTRICAL
MANUFACTURER'S ASSOCIATION
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NO. NUMBER
NOM NOMINAL
NTS, N.T.S. NOT TO SCALE
OB OUTLET BOX
OC ON CENTER
OD OUTSIDE DIAMETER
OF OVERFLOW
OH OVERHEAD
OPNG OPENING
OPER OPERATING
OSHA OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION
OS&Y OUTSIDE SCREW & YOLK
OXY OXYGEN
P PUMP
Pa PASCAL
PD PRESSURE DROP
PG PRESSURE GAUGE
PH PHASE
PLBG PLUMBING
PLC PUMP LEVEL CONTROL(S)
PNL PANEL
POC POINT OF CONNECTION
POD POINT OF DISCONNECT
PRESS PRESSURE
PS PRESSURE SWITCH
PV PLUG VALVE
PVC POLYVINYL CHLORIDE
P/TRV PRESSURE / TEMPERATURE RELIEF
VALVE
QTY QUANTITY
R RADON
(R) RELOCATED
RE: REFERENCE, REFER
RECIRC RECIRCULATE
REINF REINFORCING
REQD REQUIRED
REV REVISION, REVISE
RH ROOF HYDRANT
RLA RUNNING LOAD AMPERES
RM ROOM
RPM REVOLUTIONS PER MINUTE
SECT SECTION
SEER SEASONAL ENERGY EFFICIENCY RATIO
SH SHOWER
SHD SHOWER DRAIN
SIM SIMILAR
SK SINK
SMACNA SHEET METAL AND AIR CONDITIONING
CONTRACTORS NATIONAL
ASSOCIATION
SM SQUARE METER
SOV SHUT-OFF VALVE
SP SUMP PUMP
SPEC SPECIFICATION
SQ SQUARE
SS SANITARY SEWER
STD STANDARD
STRUC STRUCTURAL
SW COLD WATER (SOFT)
SV SUPPLY VALVE
SYM SYMBOL
S=% SLOPE AT PERCENTAGE SHOWN
TD TRENCH DRAIN
TDH TOTAL DYNAMIC HEAD
TEMP TEMPERATURE
THRU THROUGH
TMV THERMOSTATIC MIXING VALVE
TOP, T.O.P. TOP OF PIPE
TP TRAP PRIMER OR TRAP PRIMING
TYP TYPICAL
TW TEPID WATER
TWR TEPID WATER RETURN
U/F UNDER FLOOR
U/G UNDERGROUND
U/S UNDER SLAB
UFC UNIFIED FACILITIES CRITERIA
UL UNDERWRITERS LABORATORIES, INC.
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER SUPPLY
UR URINAL
UTR UP THROUGH ROOF
V VENT
VAC VOLTAGE ALTERNATING CURRENT
VBF VENT BELOW FLOOR
VEL VELOCITY
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VLV VALVE
VOR VALVE ON RISER
VTR VENT THROUGH ROOF
W WATTS
W/ WITH
W/O WITHOUT
WAP WALL ACCESS PANEL
WC WATER CLOSET
W.C. WATER COLUMN
WCO WALL CLEANOUT
WH WALL HYDRANT
WHA WATER HAMMER ARRESTOR
WM WATER METER
WP WEATHER PROOF
WPD WATER PRESSURE DROP
WS WATER SOFTENER
WSFU WATER SUPPLY FIXTURE UNITS
WT WEIGHT
PLUMBING GENERAL NOTES
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
<<PM/DM>>
BRANCH MANAGER
CHIEF ENG/ARCH
<<XX>>
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
NTS
/2
/2
:2
:0
A
M
OSB-P-001
288114
C R
A N
E
IN
D
IA
N
A
WE WE AB
P L U
M B
IN
G
S Y
M B
O L S
N
O T
E S
A
N D
A B
B R
E V
IA
T
IO
N
S
N S
A C
R A
N E
U N
D E
R W
A T
E R
L A
U N
C H
T E
S T
F A
C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C T
F -P
-0
P L U
M B
IN
G
S Y
M B
O L
S
N O
T E
S A
N D
A B
B R
E V
IA
T
IO
N
S
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
O V
E R
T H
E S
H O
U L
D E
R R
E V
IE
W
/2 /2 stmurphy stmurphy
1234567
A
B
C
D
E
A.8
D.2
4"Ø SS
2 1/2"Ø DCW
WH-1
WH-1
HB-1
HB-1
ESE-1
ST-1
FS-1
OFFICE
ELECTRICAL ROOM
INSTRUMENTATION
ROOM
LAUNCH CONTROL
CENTER
COMMUNICATION
ROOM
UNISEX TLT
UNISEX TLT
JAN. CL
BREAK ROOM
LOCKABLE TOOL CRIB
LCC EQUIPMENT
ROOM
CONFERENCE ROOM
LTV & CANISTER
MAINTENANCE AREA
CORRIDOR
4"Ø SS
1/
2" Ø
C A
2"Ø DCW
AC-1
2 1/2"Ø DCW
WH-1
IWH
OSB-P-101
C1
1 1/2"Ø CA
BFP-1
FS-1
ESE-2
IWH
1 1/4"Ø DCW
1 2 1
1 2
3/4"Ø CD
3/4"Ø CD
3/4"Ø CD
3/4"Ø CD3/4"Ø CD
3/ 4"
Ø C
D
3/ 4"
Ø C
D
FCO
1/
2" Ø
C A
IWH
IB-1
3/4"Ø DCW
OFFICE
OFFICE
4"Ø R
4"Ø SS
WH-1
E
D.2
IWH
FD-2
FD-1
FD-1
IWH
IWH
1 1/2"Ø DCW
3/4"Ø DCW 3/4"Ø CD
FCO
WC-1 WC-1
L-1L-1
MSB-1
CORRIDOR
UNISEX TLT
UNISEX TLT
JAN. CL
4"Ø SS
6 1 1/4"Ø V
2"Ø V
2"Ø V
GENERAL NOTES:
A. REFER TO OSB-P-001 FOR PLUMBING SYMBOLS, NOTES,
AND ABBREVIATIONS.
B. ALL UNDERGROUND RADON PIPING TO BE PERFORATED
PVC. ALL ABOVE GRADE RADON PIPING TO BE SOLID
PIPE.
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
<<PM/DM>>
BRANCH MANAGER
CHIEF ENG/ARCH
<<XX>>
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
As indicated
/2
/2
:2
:0
A
M
OSB-P-101
288115
C R
A N
E
IN
D
IA
N
A
WE WE AB
P L U
M B
IN
G
F L O
O R
P L A
N
N S
A C
R A
N E
U N
D E
R W
A T
E R
L A
U N
C H
T E
S T
F A
C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C T
F -P
-1
P L U
M B
IN
G
F L O
O R
P L
A N
1/8" = 1'-0"A1
PLUMBING FLOOR PLAN
1/4" = 1'-0"C1
ENLARGED PLUMBING PLAN
PLAN NORTH
8'4' 16'0
SCALE: 1/8"=1'-0"
0 2' 4' 8'
SCALE: 1/4" = 1'-0"
KEYNOTES:
1 COMPRESSED AIR DROP TO LUBRICATED AIR HOSE
CONNECTION. REFER TO DETAIL B2 / OSB-P-501 FOR
MORE INFORMATION.
2 COMPRESSED AIR DROP TO DRY AIR HOSE
CONNECTION. REFER TO DETAIL B2 / OSB-P-501 FOR
MORE INFORMATION.
3 INDOOR WALL MOUNTED HVAC UNIT PROVIDED BY
MECHANICAL CONTRACTOR. UNIT PROVIDED WITH
WALL MOUNTED CONDENSATE PUMP. REFER TO
MECHANICAL PLANS FOR ADDITIONAL INFORMATION.
4 4"Ø RADON PIPING UP THROUGH ROOF.
5 TERMINATE CONDENSATE DRAIN 6" ABOVE MOP SINK
BASIN. CUT DRAIN PIPING AT 45 DEGREE ANGLE TO
MINIMIZE SPLASHING.
6 3"Ø VENT THROUGH ROOF
7 PROVIDE EXTERIOR CLEANOUT WITHIN 5'-0" OF
BUILDING.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
O V
E R
T H
E S
H O
U L
D E
R R
E V
IE
W
/2 /2 stmurphy stmurphy
1 1/4" TEMPERED WATER
FINISHED FLOOR
1/2" STAY-OPEN
BALL VALVE
1" (STAY OPEN) BALL VALVE
SHOWER HEAD
PULL ROD
BOWL
PUSH FLAG HANDLE
MOUNT LIGHT AND ALARM ON
WALL AT 8'-0"± AFF.
1-1/4" HW
1-1/4" CW
INSTANTANEOUS
WATER HEATER
FINISHED WALL
WALL BOX
FLANGE
WALL CLAMP (IF
USED)
INLET CONNECTION
INSIDE BACK OF WALL
TO FIXTURE
HOT INLET
CONTROLS
IN-LINE FLOW
TO FILTER
COLD INLET
ANGLE STOP VALVE
1/2" THREE WAY
JUNCTION
BOX
WATER HEATER
ALL QUICK DISCONNECT COUPLINGS AND
FITTINGS SHALL MATCH OWNER'S
EXISTING EQUIPMENT AND SHALL BE
VERIFIED SPEEDAIRE MODEL 42L01
AIRLINE FILTER/REGULATOR
5-150 PSI, MAX FLOW 140 CFM
BALL VALVE
1/2"
1/2" QUICK DISCONNECT
COUPLINGS
3/4"
3' -0
6" A
IR
G
A P
6" A
IR
G
A P
3' -0
SUPPORT
STAND, TYP
WATER TO
DOMESTIC SYSTEM
BFP WITH GATE
VALVES
STRAINER
FLOOR SINK ANCHOR TO
FLOOR
DOMESTIC
WATER SERVICE
A
A
RUN FULL SIZE TO
FLOOR DRAIN
4" FLOOR SINK ANCHOR TO FLOOR
SUPPORT
STAND, TYP
STRAINER
WATER SERVICE
REDUCED PRESSURE
BACKFLOW PREVENTER
BALL VALVE
FINISH FLOOR
SECTION A-A
GATE VALVE
CUT DRAIN LINE AT 45
DEGREE ANGLE TO
MINIMIZE SPLASHING
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
<<PM/DM>>
BRANCH MANAGER
CHIEF ENG/ARCH
<<XX>>
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
As indicated
/2
/2
:2
:0
A
M
OSB-P-501
288116
C R
A N
E
IN
D
IA
N
A
WE WE AB
P L U
M B
IN
G
D E
T A
IL
S
N S
A C
R A
N E
U N
D E
R W
A T
E R
L A
U N
C H
T E
S T
F A
C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C T
F -P
-5
P L U
M B
IN
G
D E
T A
IL
S
NOT TO SCALEA1
EMERGENCY SHOWER UNIT DETAIL
NOT TO SCALEB1
FREEZE PROOF WALL HYDRANT DETAIL
NOT TO SCALED1
INSTANTANEOUS ELECTRIC WATER
HEATER DETAIL
NOT TO SCALEB2
WALL MOUNTED COMPRESSED AIR
DETAIL
NOT TO SCALEA2
WATER SERVICE ENTRY DETAIL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
O V
E R
T H
E S
H O
U L
D E
R R
E V
IE
W
/2 /2 stmurphy stmurphy
O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
<<PM/DM>>
BRANCH MANAGER
CHIEF ENG/ARCH
<<XX>>
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
/2 /2
:2
:0
A
M
OSB-P-601
288117
C R
A N
E
IN
D
IA
N
A
WE WE AB
P L U
M B
IN
G
S C
H E
D U
L E
S
N S
A C
R A
N E
U N
D E
R W
A T
E R
L A
U N
C H
T E
S T
F A
C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C T
F -P
-6
P L U
M B
IN
G
S C
H E
D U
L E
S
PLUMBING FIXTURE SCHEDULE
MARK FIXTURE
MINIMUM CONNECTION SIZE
DESCRIPTION
SS V CW HW TW
BFP-1 BUILDING BACKFLOW PREVENTER 2 1/2" REDUCED PRESSURE ZONE BACKFLOW PREVENTER WITH STRAINER, AIR GAP FITTING, AND NON-RISING STEM GATE VALVES
ESE-1 EXTERIOR EMERGENCY SHOWER / EYEWASH 3"
1 1/4" NON-FREEZE, EXTERIOR SAFETY SHOWER WITH EYE WASH, GALVANIZED STEEL PIPING, PLASTIC SHOWERHEAD AND BOWL. WATER FILLED PIPING UP TO STAY-OPEN BALL VALVE TO BE
LOCATED IN HEATED AREA. FLOW SWITCH ACTIVATED ALARM SYSTEM WITH COMBINATION ALARM HORN/STROBE AND DOUBLE THROW SWITCH FOR CONNECTION TO MONITORING SYSTEM, NEMA 4X WEATHERPROOF. PROVIDE LOCKABLE SHUTOFF VALVE LOCKED IN THE NORMALLY OPEN POSITION.
ESE-2 EMERGENCY SHOWER / EYEWASH
1 1/4" SAFETY SHOWER WITH EYE-FACE WASH, GALVANIZED STEEL PIPING, PLASTIC SHOWERHEAD AND BOWL. PROVIDE FLOW SWITCH ACTIVATED ALARM SYSTEM WITH COMBINATION ALARM
HORN/STROBE AND DOUBLE THROW SWITCH FOR CONNECTION TO MONITORING SYSTEM, NEMA 4X WEATHERPROOF. PROVIDE LOCKABLE SHUTOFF VALVE LOCKED IN THE NORMALLY OPEN
POSITION.
FCO FLOOR CLEANOUT SIZE SAME AS PIPING CONNECTED TO, SEE FLOOR PLANS AND ISOMETRICS FOR SIZING; PROVIDE WITH TRAFFIC RATED COVER.
FD-1 FLOOR DRAIN 2" 1 1/2" CAST IRON ADJUSTABLE COLLAR AND 7"ø NICKEL BRONZE STRAINER.
FD-2 FLOOR DRAIN 3" 2" CAST IRON ADJUSTABLE COLLAR AND 7"ø NICKEL BRONZE STRAINER.
FS-1 FLOOR SINK 4" 2" 12" x 12" x 8" DEEP FLOOR SINK WITH CAST IRON GRATE.
HB-1 HOSE BIBB 3/4" HOSE BIBB WITH INTEGRAL VACUUM BREAKER, 3/4" MALE HOSE THREAD OUTLET, SECURED WHEEL HANDLE WITH VANDAL RESISTANT OPERATING STEM, ROUGH CHROME FINISH.
IB-1 ICE MAKER BOX 1/2" WALL MOUNTED ICE MAKER BOX WITH QUARTER TURN HANDLES
L-1 LAVATORY 1 1/4" 1 1/4" 1/2" 1/2" WALL HUNG WITH 0.5 GPM MANUAL FAUCET
MSB-1 MOP SINK BASIN 3" 2" 1/2" 1/2" 24"X24" TERRAZZO MOP SINK BASIN WITH HOSE BRACKET, HOSE, STAINLESS STEEL CAPS
SK-1 SINK 1 1/2" 1 1/4" 1/2" 1/2" UNDERMOUNT 32"X19"X9" DOUBLE STAINLESS STEEL SINK WITH 1.5 GPM MANUAL FAUCET
ST-1 SAND TRAP 4" 24"X24" HEAVY DUTY GRATE. 60 GALLON CAPACITY.
WC-1 WATER CLOSET 4" 2" 1" WALL HUNG WITH MANUAL 1.28 GPF FLUSH VALVE
WH-1 WALL HYDRANT 3/4"
CHROME-PLATED QUARTER TURN NON-FREEZE AUTOMATIC DRAINING HYDRANT WITH STAINLESS STEEL BOX, 3/4" MALE HOSE THREAD OUTLET CONNECTION, INTEGRAL VACUUM BREAKER, INTEGRAL SERVICE SHUTOFF VALVE, DUAL CHECK VALVE, "T" HANDLE KEY, ROUGH BRONZE FACE PLATE WITH FULL 180 DEGREE COVER OPENING.
INSTANTANEOUS WATER HEATER SCHEDULE
MARK SERVES LOCATION FLOW CAPACITY
TEMPERATURE
RISE @ FLOW
OUTLET
TEMPERATURE
ELECTRICAL
NOTESMCA VOLTAGE PHASE
IWH-01 KITCHEN SINK 111 - BREAK ROOM 1.5 GPM 20.0 kW 61 °F 110 °F 24 A 460 V 3
IWH-02 MOP SINK BASIN 114 - JAN. CL 2.2 GPM 24.0 kW 68 °F 120 °F 29 A 460 V 3
IWH-03 LAVATORY 115 - UNISEX TLT 0.5 GPM 4.1 kW 56 °F 105 °F 20 A 208 V 1
IWH-04 LAVATORY 116 - UNISEX TLT 0.5 GPM 4.1 kW 56 °F 105 °F 20 A 208 V 1
IWH-05 EMERGENCY EYEWASH / SHOWERS 101 - LTV & CANISTER MAINTENANCE AREA 20.0 GPM 96.0 kW 33 °F 85 °F 116 A 460 V 3
IWH-06 EMERGENCY EYEWASH / SHOWERS 101 - LTV & CANISTER MAINTENANCE AREA 20.0 GPM 96.0 kW 33 °F 85 °F 116 A 460 V 3
WATER HAMMER ARRESTER SCHEDULE
MARK FIXTURE UNITS PIPE SIZE HEIGHT DIAMETER NOTES
WHA-A 1-11 3/4" 2.62" 3.25" 1
WHA-B 12-32 1" 2.97" 3.25" 1
WHA-C 33-60 1" 3.59" 3.25" 1
WHA-D 61-113 1" 5.14" 3.25" 1
WHA-E 114-154 1" 5.52" 3.25" 1
WHA-F 155-330 1" 6.67" 3.25" 1
AIR COMPRESSOR SCHEDULE
MARK SERVES TYPE FLOW @ 90 PSI
MAXIMUM
PRESSURE TANK VOLUME HP
ELECTRICAL
WEIGHT NOTESVOLTAGE PHASE
AC-1 101 - LTV & CANISTER MAINTENANCE AREA RECIPROCATING 50 CFM 175 psi 120 gal 15 hp 460 V 3 1,600 lb 1
NOTES:
1. LOCATED OUTSIDE OF BUILDING. PROVIDE WITH HEATED ENCLOSURE. HEATED ENCLOSURE TO HAVE MANUFACTURER'S RECOMMENDED CLEARANCE ON ALL SIDES
FOR MAINTENANCE.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
O V
E R
T H
E S
H O
U L
D E
R R
E V
IE
W
/2 /2 stmurphy stmurphy
IWH
ESE-1
HB-1
IWH
ESE-2
BFP-1
HB-1
WH-1
WH-1
WH-1
IWH
IB-1
IWH
IWH
IWH
WH-1
MSB-1
WC-1
WC-1
L-1 L-1
SK-1
1 1/4"Ø DHW
1 1/4"Ø DCW
3/4"Ø DCW
3/4"Ø DCW
3/4"Ø DCW
1"Ø DCW
2 1/2"Ø DCW
1 1/4"Ø DCW
2 1/2"Ø DCW
3/ 4"
Ø D
C W
2 1/2"Ø DCW
2"Ø DCW
3/4"Ø DCW
2"Ø DCW
1 1/2"Ø DCW 3/4"Ø DCW
3/4"Ø DCW
3/4"Ø DCW
1 1/2"Ø DCW
1/2"Ø DHW
1/2"Ø DCW
1/2"Ø DCW3/4"Ø DCW
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
<<PM/DM>>
BRANCH MANAGER
CHIEF ENG/ARCH
<<XX>>
JACOBS ENGINEERING GROUP INC.
412 MT. KEMBLE AVENUE
MORRISTOWN, NJ 07960
PHONE: (973) 267-0555
1 2 3 4 5
/2 /2
:2
:1
A
M
OSB-P-901
288118
C R
A N
E
IN
D
IA
N
A
WE WE AB
P L U
M B
IN
G
I S
O M
E T
R
IC
S
N S
A C
R A
N E
U N
D E
R W
A T
E R
L A
U N
C H
T E
S T
F A
C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C T
F -P
-9
P L U
M B
IN
G
I S
O M
E T
R
IC
S
A1
DOMESTIC WATER PIPING ISOMETRIC
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
O V
E R
T H
E S
H O
U L
D E
R R
E V
IE
W
/2 /2 stmurphy stmurphy
4"Ø SS
ESE-1
ST-1
FCO
4"Ø SS
4" Ø
S S
4"Ø SS
FS-1
FS-1
ESE-2
4"Ø SS
FD-1
WC-1
W C
-1
MSB-1
FD-2
FCO
L-1
L-1
3/4"Ø CD
3/4"Ø CD
3/4"Ø CD
3/4"Ø CD
3/4"Ø CD
3/4"Ø CD
3/4"Ø CD
4"Ø SS
SK-1
WALL HUNG HVAC UNIT
PROVIDED BY MECHANICAL
CONTRACTOR. REFER TO
MECHANICAL PLANS FOR
ADDITIONAL INFORMATION.
WALL HUNG HVAC UNIT
PROVIDED BY MECHANICAL
CONTRACTOR. REFER TO
MECHANICAL PLANS FOR
ADDITIONAL INFORMATION.
WALL HUNG HVAC UNIT
PROVIDED BY MECHANICAL
CONTRACTOR. REFER TO
MECHANICAL PLANS FOR
ADDITIONAL INFORMATION.
FCO
2"Ø V
3"Ø V
3"Ø V
2"Ø V
3"Ø V
2"…
This is the start of the file's text. The full file is on GovTribe.