N4008519R9186_B_2019-04-24_CTF_Drawing_Set_OTS_Review.pdf

PDF 16 MB Posted

Attached to
Industry Day on 19-20 June 2019 for P-409 Underwater Launch Test Facility (ULTF), Naval Support Activity Crane, Crane, IN
Solicitation number
N4008519R9186
Issued by

About this file

This special notice announces an industry day for a proposed military construction project located at Naval Support Activity Crane in Crane, Indiana. The project involves construction of an Underwater Launch Test Facility including a 130-foot deep pool, operational support building, warehouse building, water treatment facility, and mechanical and electrical building. Supporting facilities include site work, utilities, and environmental mitigation. The magnitude of construction is estimated between $25 million and $100 million. Firms interested in participating in the industry day on June 19-20, 2019 are requested to respond by June 12 with names and contact information. The event will include a project description and presentation at the Indianapolis airport hotel followed by an optional site visit. Preliminary design documents will be posted to NECO by June 5 for review. This announcement provides information but does not constitute a solicitation or commitment on the part of the government.

N4008519R9186_B_2019-04-24_CTF_Drawing_Set_OTS_Review.pdf

View the file

Other files

File Type Posted
N4008519R9186 Amendment 0001.pdf PDF
2019-12-04_VOL 1_SHEET 051-061_RFP PHASE I SUBMISSION.pdf PDF
2019-12-04_VOL 1_SHEET 136-153_RFP PHASE I SUBMISSION.pdf PDF
2019-12-04_VOL 1_SHEET 062-079_RFP PHASE I SUBMISSION.pdf PDF
2019-12-04_VOL 1_SHEET 080-095_RFP PHASE I SUBMISSION.pdf PDF
2019-12-04_VOL 1_SHEET 038-050_RFP PHASE I SUBMISSION.pdf PDF
Amendment 0001.pdf PDF
2019-12-04_VOL 1_SHEET 118-135_RFP PHASE I SUBMISSION.pdf PDF
2019-12-04_VOL 1_SHEET 154-221_RFP PHASE I SUBMISSION.pdf PDF
2019-12-04_VOL 1_SHEET 096-117_RFP PHASE I SUBMISSION.pdf PDF
Sign-In Sheet.pdf PDF
N4008519R9186_10038_20190415_Model.pdf PDF
N4008519R9186_ULTF_-_Draft_Logs_061219.pdf PDF
N4008519R9186_P-409_Industry_Day_Flyer_6-19-2019_Final.pdf PDF
N4008519R9186_I_2019-04-24_CTF_Drawing_Set_OTS_Review.pdf PDF
N4008519R9186_J_2019-04-24_CTF_Drawing_Set_OTS_Review.pdf PDF
N4008519R9186_K_2019-04-24_CTF_Drawing_Set_OTS_Review.pdf PDF
N4008519R9186_F_2019-04-24_CTF_Drawing_Set_OTS_Review.pdf PDF
N4008519R9186_H_2019-04-24_CTF_Drawing_Set_OTS_Review.pdf PDF
N4008519R9186_G_2019-04-24_CTF_Drawing_Set_OTS_Review.pdf PDF
N4008519R9186_E_2019-04-24_CTF_Drawing_Set_OTS_Review.pdf PDF
N4008519R9186_D_2019-04-24_CTF_Drawing_Set_OTS_Review.pdf PDF
N4008519R9186_C_2019-04-24_CTF_Drawing_Set_OTS_Review.pdf PDF
N4008519R9186_A_2019-04-24_CTF_Drawing_Set_OT_Review.pdf PDF
N4008519R9186_P-409_Industry_Day_Flyer_6-19-2019_KRS4.pdf PDF
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F I L E

N

A M

E

C p w w o r k i n g g b n a d a x e s h p d C

T F

C d w g

Y O

U T

M

E

C

T F

C

P

O

T T

E D

T u e s d a y

A p r i l p m

S E

R p a t e l d

L T

F

S

A N

I T

A R

Y

S

E W

R

D

T

A I L

S

CTF-C-501

AS NOTED

KM MD KM

M I N

30"

NOTES:

1. RUNGS SHALL BE STEEL REINFORCED POLYPROPYLENE.

2. MANHOLE RUNGS TO BE INSTALLED FACING TRAFFIC WHEN STRUCTURE IS IN A TRAVEL LANE, AND

PERPENDICULAR TO TRAFFIC FLOW WHEN STRUCTURE IS INSTALLED ON ROADWAY CENTERLINE.

3. REFER TO GRADING/UTILITY PLAN FOR PIPE LOCATION.

FINAL GRADE

PRE-CAST GRADE RINGS (2 MAX.)

PRE-CAST ECCENTRIC CONE SECTION

TWO SEPARATE COATS OF APPROVED BITUMASTIC

WATERPROOFING COMPOUND SHALL BE APPLIED PER

MANUFACTURER'S INSTRUCTIONS, TO ENTIRE

STRUCTURE

PRE-CAST RISER SECTIONS

(AS REQUIRED)

PRE-CAST MANHOLE SECTIONS TO BE CONSTRUCTED &

REINFORCED IN ACCORDANCE W/ ASTM SPECIFICATION

C-478-90b.

RUBBER GASKET & CEMENT GROUT AT EACH JOINT IN

CONFORMANCE WITH ASTM C-443.

PRE-CAST BASE SECTION

COMPACTED AGGREGATE,

NO. 53, BASE

UNDISTURBED SOIL/COMPACTED

FILL PER PROJECT SPECIFICATIONS

MANHOLE RUNGS @ 12" O.C.

48" MIN.

5" (MIN.)

T

O

V A

R I E

S

12" MIN.

6"

CLASS "C" CONCRETE

FILL

2" MIN.

SMOOTH CONCRETE CHANNEL - DEPTH EQUAL TO 0.80

TIMES DIA. OF MAIN SEWER FOR SIZES LESS THAN 16"

AND 0.50 TIMES DIA. OF MAIN SEWER FOR SIZES 16" AND

LARGER.

PLAN

3000 PSI CONCRETE

4"

4"

4" 4"

10' MIN. 10' MIN.

NEW SANITARY SEWER

MAIN

WATER MAIN

A

CTF-C-501CTF-C-501

ENCASEMENT - SECTION A-A

SCALE: N/A

CAST IRON MANHOLE COVER

N O

T

FO

R C

O N

S

TR

U C

TI

O

N

P R

E L

IM

IN

A

R Y

D E

P A

R T

M E

O

T

H

V

Y

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

P-

UN

DE

R

W

AT

ER

L

AU

NC

H

TE

ST

F

AC

IL

IT

Y

N S

A

C

R A

N E

C R

A N

E

I N

D I A

N A

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

O V

O

U L D

V

I E

W

COMPACTED AGGREGATE,

NO. 53, BASE

UNDISTURBED SOIL/COMPACTED

FILL PER PROJECT SPECIFICATIONS

6"

B3

PRE-CAST MANHOLE DETAIL

NOT TO SCALE

B4

SANITARY SEWER ENCASEMENT

NOT TO SCALE

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

stmurphy stmurphy Typewritten Text

CONCEPT DEVELOPMENT

℄ GUY ANCHOR

RADIUS (SEE CIVIL FOR

LOC.)

℄ GUY ANCHOR

RADIUS (SEE CIVIL FOR

LOC.)

℄ G U

Y

A

N C

H O

R

R A

D I U

S

S

C

V

R

L O

C

℄ 60M TOWER FDN.

(SEE CIVIL FOR LOC.)

F I

M

E

C p w w o r k i n g g b n a d a x e s h p d C

T F

C d

Y O

M

E

C

T F

C

O

T T

E D

T u e s d a y

A p r i l

E

R p a t e l d

N O

T

FO

R C

O N

S

TR

U C

TI

O

N

P R

E L

IM

IN

A

R Y

D E

P A

R T

M E

T

V

Y

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

P-

UN

DE

R

W

AT

ER

L

AU

NC

H

TE

ST

F

AC

IL

IT

Y

N S

A

C

R A

N E

C R

A N

E

I N

D I A

N A

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

O V

O

U L D

V

I E

W

C T

F

C

O N

S T

R U

C T

I O

N

D

E T

A I L

S

CTF-C-502

AS NOTED

KM MD KM

1. SEE DWG CTF-S-XX THRU CTF-S-XX FOR NOTES & DESIGN CRITERIA.

NOTE:

2"

2"

TENSION BAR

TENSION BAND

TERMINAL POST CAP

BRACE BAND

LINE POST TOP

D

I A

G

O

N

B

A

Ø

TOP RAIL

END CAP

FABRIC CONTINUED

OVER TOP OF

UPPER RAIL

1 5/8" DIA.

SCHEDULE 40

ZINC-COATED TOP

AND BRACE RAIL

2", 9 GAUGE

ZINC-COATED

STEEL WIRE MESH

3 1/2" DIA.

SCHEDULE 40

ZINC-COATED

TERMINAL POST

BRACE BAND FOR

TENSION WIRE

12"

10'-0" MAXIMUM POST SPACING

PLUG END

OF POST

TENSION WIRE

CLIPS

BOTTOM TENSION

WIRE

FENCE TIES

(TYP.)

2 7/8" DIA.

SCHEDULE 40

ZINC-COATED

LINE POSTS

2"

CONCRETE FOUNDATION, 4,000 PSI (TYP.)

NOTES:

1. ZINC COAT ALL MATERIALS.

2. CONFORM TO THE REQUIREMENTS OF A.S.T.M. M181-60.

12"

WELDED GATE

FABRIC TIE

SWING GATE

10'-0"

POST CAP (TYP.)

BRACE BAND (TYP.)

GATE LATCH (TYP.)

4" DIA. SCHEDULE 40 ZINC-COATED

END POST (TYP.)

CONCRETE FOUNDATION

4,000 PSI (TYP.)

NOTES:

1. ZINC COAT ALL MATERIAL.

2. CONFORM TO ASTM M181-60 REQUIREMENTS.

3. FINAL DESIGN PER FENCE MANUFACTURER.

2" 9 GAUGE ZINC-COATED

STEEL WIRE MESH (TYP.)

16"

2" TUBE, GALVANIZED

SCHEDULE 40 (TYP.)

FINISH GRADE

VARIES (SEE CIVIL)

M I N

UNDISTURBED SOIL

SEE NOTE "1"

T.O.C. ELEV

(SEE SCHEDULE)

F O

U N

D A

T I O

N

D

E P

T H

15"

WELD 1/2" X 6" DIA.

PLATE TO 1 1/4"

DIA. ANCHOR ROD

EYE BOLT W/ NUT FOR 1 1/4" - 7

THREAD SIZE ROD

1/4" DIA GUY

ROPE PER

MANUFACTURER

1/2" THICK STABILIZER

PLATE WITH HOOK

& BOLT FOR TWO

GUY ROPES CONNECTION

#5 VERTICAL BARS

SEE SCHEDULE

3-#4 TIES @ TOP

@ 4" O/C

HOOK WITH BOLT

1. FOUNDATION SHALL BE SURROUNDED BY "UNDISTURBED" SOIL. DO NOT REMOVE MORE SOIL

FROM SIDES THAN IS NECESSARY.

NOTES:

"LENGTH" DIM.

W

I D

T H

D

I M

15"

#5 VERTICAL BARS

SEE SCHEDULE

#4 TIES SEE

SCHEDULE

GUY ROPE ANCHOR

ASSEMBLY (TYP.)

TOWARDS TOWER

60 METER TOWER FOUNDATION SCHEDULE

G1,G2,G3

ANGLE FOR

GUY ANCHOR ROD

GUY ANCHOR

FOUNDATION TYPE

SIZE LENGTH x

WIDTH x DEPTH

T.O.C. ELEV

4'x4' X 8'-6" T.B.D.

VERTICAL

REINFORCEMENT

HORIZONTAL TIE

REINFORCEMENT

58.0° 16 # 5

#4 @ 10" O.C.

G4

GUY ANCHOR T.B.D.

G5

GUY ANCHOR T.B.D.

G6

GUY ANCHOR T.B.D.

G10

GUY ANCHOR T.B.D.

G11

GUY ANCHOR T.B.D.

G12

GUY ANCHOR T.B.D.

G13 TOWER ANCHOR 10'x10' X 6'-6" T.B.D.

58.0°

58.0°

58.0°

58.0°

58.0°

58.0°

SEE MANUFACTERS

FOR ANCHOR BOLTS

16 # 5

16 # 5

16 # 5

16 # 5

16 # 5

16 # 5

1. TOWER FOUNDATION DESIGN CONFORMS TO "STRUCTURAL STANDARDS FOR STEEL ANTENNA TOWERS AND ANTENNA SUPPORTING

STRUCTURES"-ANSI/TIA-222 REV "G" 2009.

2. DESIGN FASTEST-MILE WIND SPEED IS 105 MPH BASED ON 125 MPH 3-SECOND GUST WIND SPEED. (T.B.D.)

3. MAXIMUM TOWER SUPPORT REACTION PER ADVANCED MAST SYSTEM, INCORPORATED FOR 60 METER METEOROLOGICAL MAST AS FOLLOWS:

TOWER BASE : DOWN THRUST = 24.70 KIPS

SHEAR = 0.30 KIPS

GUY ANCHOR @ R=70': UPLIFT = 1.09 KIPS

SHEAR = 1.82 KIPS

GUY ANCHOR @ R=90': UPLIFT = 2.97 KIPS

SHEAR = 2.60 KIPS

GUY ANCHOR @ R=110': UPLIFT = 4.94 KIPS

SHEAR = 3.32 KIPS

4. PER GEOTECHNICAL REPORT BY (T.B.D.)

5. REDUCED SOIL PARAMETERS ARE AS FOLLOWS:

PASSIVE EARTH PRESSURE RESISTANCE

W/ NEGLECTING UPPER 2' OF SOIL = 180 PSF/FT

FRICTIONAL RESISTANCE COEFFICIENT FOR

TOWER FOUNDATION = 0.3

NO BASE FRICTION RESISTANCE FOR

GUY ROPE ANCHOR FOUNDATION = 0.0

SOIL BEARING PRESSURE = 3,000 PSF

60 METER TOWER DESIGN CRITERIA:

LENGTH x WIDTH (SEE 60 METER TOWER FOUNDATION SCHEDULE)

F O

U N

D A

T I O

N

D

E P

T H

(2) #6 ON

EACH FACE

(10) #6 BARS

TOP & BOTTOM

EACH WAY

EQUAL SPACING

G7,G8,G9

GUY ANCHOR T.B.D. 58.0° 16 # 5

2. ALL TIE ROD ASSEMBLY. FORGED STEEL PER FEDERAL SPEC. WW-H-171E & A-A-1192A TYPE 17

ANCHOR BOLTS AS PER

MANUFACTURER STANDARD

G14 SOLAR PANEL PAD 10'x10' X 0'-8" T.B.D.

G15 TILT ANCHOR 4'x4' X 8'-6" T.B.D.

AS PER ERECTION 16 # 5

G16 TILT ANCHOR 4'x4' X 8'-6" T.B.D.

16 # 5

G17 TILT ANCHOR 4'x4' X 8'-6" T.B.D.

16 # 5

AS PER ERECTION

AS PER ERECTION

M I N

M I N

#4 @ 10" O.C.

#4 @ 10" O.C.

#4 @ 10" O.C.

#4 @ 10" O.C.

#4 @ 10" O.C.

#4 @ 10" O.C.

#4 @ 10" O.C.

4'x4' X 8'-6"

4'x4' X 8'-6"

4'x4' X 8'-6"

4'x4' X 8'-6"

4'x4' X 8'-6"

4'x4' X 8'-6"

4'x4' X 8'-6"

#4 @ 10" O.C.

#4 @ 10" O.C.

#4 @ 10" O.C.

SEE SECTION "7"

SEE LTF-C-506/2

SEE SECTION "7"

SEE LTF-C-506/2

COMPACTED AGGREGATE,

NO. 53, BASE

UNDISTURBED SOIL/COMPACTED FILL

PER PROJECT SPECIFICATIONS

COMPACTED AGGREGATE,

NO. 53, BASE

UNDISTURBED

SOIL/COMPACTED FILL

PER PROJECT

SPECIFICATIONS

A1

TOWER GUY ANCHOR FOUNDATION SECTION

SCALE: 1/2"=1'-0"

A2

GUY ANCHOR FOUNDATION PLAN

SCALE: 1/2"=1'-0"

A4

60 METER TOWER FOUNDATION SECTION

SCALE: 1/2"=1'-0"

C2

7' HEIGHT CHAIN LINK FENCE DETAIL

NOT TO SCALE

C4

7' HEIGHT FENCE - 10' WIDE GATE DETAIL

NOT TO SCALE

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text stmurphy stmurphy

M

E

C p w w o r k i n g g b n a d a x e s h p d C

T F

C d

Y O

M

E

C

T F

C

O

T T

E D

T u e s d a y

A p r i l

E

R p a t e l d

N O

T

FO

R C

O N

S

TR

U C

TI

O

N

P R

E L

IM

IN

A

R Y

D E

P A

R T

M E

T

V

Y

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

P-

UN

DE

R

W

AT

ER

L

AU

NC

H

TE

ST

F

AC

IL

IT

Y

N S

A

C

R A

N E

C R

A N

E

I N

D I A

N A

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

O V

O

U L D

V

I E

W

C T

F

C

O N

S T

R U

C T

I O

N

D

E T

A I L

S

CTF-C-503

AS NOTED

KM MD KM

4'-5"

(5) #5 CONTINUOUS BARS

#5 BARS @ 12" O.C. EACH WAY

8"

TYP.

BOTTOM TRENCH ELEV

VARIES, SEE CIVIL PLAN

C

L E

A R

#5 BARS @ 12" O.C.

EA WAY TOP & BOTTOM

FINISH GRADE

SEE CIVIL

PLAN

6" COMPACTED AGGREGATE, NO. 53, BASE

T

Y P

0 1' 2'

8" (TYP.);

18" UNDER SURFACE

MOUNTED BOLLARDS

SEE CIVIL PLAN

#5 BARS @ 12" O.C.

EA WAY TOP & BOTTOM

CHAMFER EXPOSED

EDGES (TYP.)

T

H I C

K

T

H I C

K

0 1' 2' 3'

4'-0"

SEE DWG

CTF-C-XX

1" ISOLATION JOINT FILL W/ SEALANT (TYP.)

FINISH GRADE

SEE CIVIL

PLAN

SEE CIVIL PLAN

1'-0"

(TYP.)

C

L E

A R

40'

8"

8" (TYP.);

18" UNDER SURFACE

MOUNTED BOLLARDS

S E

E

C

I V

A

N

#4 DOWEL BARS 1'x1' @ 12" O.C.

(TYP.) INTO ADJACENT CONC

WHERE ADJACENT TO CONCRETE

#4 BAR CONTINUOUS

(TYP. BOTH SIDES)

#4 BAR CONTINOUS

(TYP. BOTH SIDES)

NOTES:

1. PROVIDE EXPANSION JOINTS, 1/2" WIDE PREMOLDED BITUMINOUS MATERIAL AGAINST ALL HARD SURFACES.

2. PROVIDE 1" ISOLATION JOINT W/ 1/2" DIA. DOWEL BAR PER DETAIL (T.B.D.) AGAINST BUILDING CONC SLAB.

3. PROVIDE PIPE SLEEVES OR OPENINGS IN CONC PAD FOR ANY UTILITIES AS PER EACH DISCIPLINES DRAWINGS.

4. REFER TO DWG (T.B.D.) FOR CONCRETE NOTES.

NOTES:

1. PROVIDE EXPANSION JOINTS, 1/2" WIDE PREMOLDED BITUMINOUS MATERIAL AGAINST ALL HARD SURFACES.

2. PROVIDE 1" ISOLATION JOINT W/ 1/2" DIA. DOWEL BAR PER DETAIL (T.B.D.) AGAINST BUILDING CONC SLAB.

3. PROVIDE PIPE SLEEVES OR OPENINGS IN CONC PAD FOR ANY UTILITIES AS PER EACH DISCIPLINES DRAWINGS.

4. REFER TO DWG (T.B.D.) FOR CONCRETE NOTES.

CHAMFER NOT REQUIRED IF

AGAINST BUILDING (TYP.)

SLOPE PER

PLAN OR 2%

NEENAH HEAVY DUTY TRENCH FRAME AND

SOLID COVER #R4990-0X OR APPROVED EQUAL

UNDISTURBED SOIL/COMPACTED FILL

PER PROJECT SPECIFICATIONS

6"

C1

TYPICAL CONCRETE APRON DETAIL

SCALE: 1"=1'

A1

TYPICAL HVAC CONCRETE PAD

SCALE: 3/4"=1'

C4

UTILITY TRENCH DETAIL

NOT TO SCALE

6" COMPACTED AGGREGATE, NO. 53, BASE

UNDISTURBED SOIL/COMPACTED FILL

PER PROJECT SPECIFICATIONS

6"

6"

1" ISOLATION JOINT FILL W/ SEALANT (TYP.)

6" COMPACTED AGGREGATE, NO. 53, BASE

UNDISTURBED SOIL/COMPACTED FILL

PER PROJECT SPECIFICATIONS

A4

CRANE PAD DETAIL

NOT TO SCALE

6" COMPACTED AGGREGATE, NO. 53, BASE

UNDISTURBED SOIL/COMPACTED FILL

PER PROJECT SPECIFICATIONS

HARDWOOD CRANE MAT

12" THICK, 96" WIDE X 40' LONG SECTIONS

FILTER FABRIC

12" MINIMUM THICKNESS OPEN GRADED

DRAINAGE LAYER (SLOPE TOWARDS DRAIN)

6" PERFORATED HDPE PIPE

12" MINIMUM COMPACTED AGGREGATE, NO. 53, BASE

UNDISTURBED SOIL/COMPACTED FILL

PER PROJECT SPECIFICATIONS

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

, TOP & BOTTOM

stmurphy stmurphy

M

E

C p w w o r k i n g g b n a d a x e s h p d C

T F

C d

Y O

M

E

C

T F

C

O

T T

E D

T u e s d a y

A p r i l

E

R p a t e l d

N O

T

FO

R C

O N

S

TR

U C

TI

O

N

P R

E L

IM

IN

A

R Y

D E

P A

R T

M E

T

V

Y

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

P-

UN

DE

R

W

AT

ER

L

AU

NC

H

TE

ST

F

AC

IL

IT

Y

N S

A

C

R A

N E

C R

A N

E

I N

D I A

N A

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

O V

O

U L D

V

I E

W

C T

F

C

O N

S T

R U

C T

I O

N

D

E T

A I L

S

CTF-C-504

AS NOTED

KM MD KM

#4 BARS @ 12" O.C.

EACH WAY (TYP.)

4,000 PSI CONCRETE

COMPACTED SUBGRADE

CUT REINFORCEMENT

AT JOINT AS SHOWN

BACKER ROD

TWO COMPONENT POLYURETHANE

BASED ELASTOMERIC SEALANT

PROVIDE 1/2" DIA. SMOOTH BARS

(DOWELS) X 1'-6" LG. GREASE &

WRAP ONE END@ 12" O.C.

PROVIDE BUTYL ROD &

FILL WITH SEALANT

PROVIDE SMOOTH BARS

(DOWELS) GREASE & WRAP

ONE END @ 12" O.C.

2"

2"

3/16" SAW CUT

2"

1/2" EXPANSION JOINT

1. SEE DWG CTFS-XX FOR CONCRETE NOTES & DESIGN CRITERIA.

2. FOR CONCRETE AND REINFORCEMENT NOTES REFERENCE CTF-C-XX.

NOTES:

CONDUIT

SEE DUCT BANK SECTIONS

3"

3" 3"

3"

B4

DUCT BANK CONCRETE ENCASEMENT DETAIL

NOT TO SCALE

A2

TYPICAL CONTRACTION JOINT DETAIL

NOT TO SCALE

A4

TYPICAL ISOLATION JOINT DETAIL

NOT TO SCALE

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

stmurphy stmurphy

M

E

C p w w o r k i n g g b n a d a x e s h p d C

T F

C d

Y O

M

E

C

T F

C

O

T T

E D

T u e s d a y

A p r i l

E

R p a t e l d

N O

T

FO

R C

O N

S

TR

U C

TI

O

N

P R

E L

IM

IN

A

R Y

D E

P A

R T

M E

T

V

Y

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

P-

UN

DE

R

W

AT

ER

L

AU

NC

H

TE

ST

F

AC

IL

IT

Y

N S

A

C

R A

N E

C R

A N

E

I N

D I A

N A

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

O V

O

U L D

V

I E

W

C T

F

C

O N

S T

R U

C T

I O

N

D

E T

A I L

S

CTF-C-505

AS NOTED

KM MD KM

2'-8" MIN. TO

6' LONG PRECAST CONC. WHEEL STOP

W/2-#4 BARS CONT. 5'-9" LONG

PARKING SURFACE

2-#4 BARS THRU WHEEL STOP &

PARKING SURFACE, MIN 18" LONG.

ON CONC. PAVEMENT USE EPOXY

BONDING AGENT

8"

EDGE OF PARKING

LOT

5'-0" OR PER PLAN

4" THICK, 4000 PSI CONCRETE FOR SIDEWALK

COMPACTED AGGREGATE, NO. 53, BASE

COURSE, 6" THICK

UNDISTURBED SOIL/COMPACTED FILL

PER PROJECT SPECIFICATIONS

NOTE:

1. PROVIDE EXPANSION JOINTS, 1/2" WIDE PREMOLDED

BITUMINOUS MATERIAL AT 15' INTERVALS, AND AGAINST ALL

HARD SURFACES, CONTRACTION JOINTS SPACED AT EQUAL

INTERVALS, 5' MAXIMUM LENGTH, 1/4" BELOW SIDEWALK

SURFACE.

6x6 - W1.4xW1.4 WELDED WIRE

FABRIC (WWF)

CHARGE CONTROLLER

EXTERNAL ON/OFF

WEATHERIZED SWITCH

FUSED BATTERY

HARNESS

TWO BATTERIES

AGM BATTERIES

12V, 111A-HR AT 100HR

WITH SPLICING TAPE

ROUND TAPERED

STEEL POLE

HANDHOLE

M

I N

LARGE 2 BATTERY ENCLOSURE

POWDER COATED ALUMINUM

BUILT TO NEMA 3R, VENTED

PADLOCK HASP

MOUNTS WITH BOLTS

17X16X15", 165 LBS, EPA 2.0 SQ-FT

1 1/4" NPS FITTER

U-BOLT, GALVANIZED STEEL,

3/8"-16 THREAD, FOR 6.0" OD

SIDE OF POLE

MOUNTING RACK

ROTATING BEACON

WITH RED COVER,

POLE TOP MOUNTED

85WATT PANEL

SIZE: 37.01 X 26.57 X 1.38"

EPA = 5.73 SQ-FT

WEIGHT: 17.42 LBS

(FACING SOUTH)

U-BOLT, GALVANIZED STEEL

RECOMMENDED PANEL TILT: 56º

FULL BASE COVER

GRADE

2'-0"

6-#6 BARS

VERTICAL

DIA.

#3 TIES BARS HORIZONTAL

12" O/C

(TYP.)

3"

3"

3"

3"

1 3/4" NPS

THREADED FITTER

U-BOLT, GALVANIZED STEEL

LIGHTING CONTROLLER

CIRCUIT BREAKERS

FOUR BATTERIES

24V, 176A-HR

AT 100HR

130W LED

LUMINAIRE

ROUND TAPERED

STEEL POLE

HANDHOLE

M

I N

IR DETECTOR FOR REMOTE

CONTROL

RECOMMENDED PANEL TILT: 56º

LARGE 4 BATTERY ENCLOSURE

POWDER COATED ALUMINUM

BUILT TO NEMA 3R, VENTED

PADLOCK HASP MOUNTS WITH BOLTS

38X16X15", 436 LBS, EPA 5.0 SQ-FT

1 1/4" NPS FITTER

PROTRUDES 3/4"

FROM POLE

U-BOLT, GALVANIZED STEEL,

3/8"-16 THREAD, FOR 6.0" OD

TWO 135WATT PANELS

SIZE: 59.1 X 26.6 X 1.4"

EPA = 16.73 SQ-FT

WEIGHT: 26.68 LBS EACH,

53.36 LBS TOTAL

(FACING SOUTH)

5'-6"

T R

A V

W

Y

4'-0" ARM

FULL BASE COVER

GRADE

3'-0"

7-#8 BARS

VERTICAL

DIA.

#3 TIES BARS HORIZONTAL

12" O/C

(TYP.)

3"

3"

3"

3"

HANDHOLE

SIDE OF POLE

MOUNTING RACK

U-BOLT, GALVANIZED STEEL

1 3/4" NPS

THREADED FITTER

U-BOLT, GALVANIZED STEEL

COMPACTED AGGREGATE, NO. 53, BASE

COURSE, 6" THICK

HMA SURFACE COURSE 9.5 MM, 2" THICK

TACK COAT

PHOTOVOLTAIC BEACON ASSEMBLY

NOT TO SCALE CTF-C-XXCTF-C-XX

PHOTOVOLTAIC LIGHTING ASSEMBLY

NOT TO SCALE CTF-C-XXCTF-C-XX

HMA INTERMEDIATE COURSE 19.0 MM, 4" THICK

NOTE:

ASSEMBLY TO WITHSTAND

100 MPH WIND LOAD

NOTE:

ASSEMBLY TO WITHSTAND

100 MPH WIND LOAD

SLOPE AWAY FROM

BASE CONNECTION

SLOPE AWAY FROM

BASE CONNECTION

GROUNDING LUG

ON POLE

GROUNDING 3/4"

PVC #4 GROUND

WIRE

GROUND ROD

5/8" X 10' ROD

GROUNDING LUG

ON POLE

GROUNDING 3/4"

PVC #4 GROUND

WIRE

GROUND ROD

5/8" X 10' ROD

UNDISTURBED SOIL/COMPACTED FILL

PER PROJECT SPECIFICATIONS

C1

BITUMINOUS PAVEMENT DETAIL

NOT TO SCALE

B1

CONCRETE SIDEWALK DETAIL

NOT TO SCALE

COMPACTED AGGREGATE, NO. 53, BASE

COURSE, 6" THICK

UNDISTURBED SOIL/COMPACTED FILL

PER PROJECT SPECIFICATIONS

A1

DUMPSTER/GRAVEL PAD DETAIL

NOT TO SCALE

A2

CONCRETE WHEEL STOP DETAIL

NOT TO SCALE

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

stmurphy stmurphy

M

E

C p w w o r k i n g g b n a d a x e s h p d C

T F

C d

Y O

M

E

C

T F

C

O

T T

E D

T u e s d a y

A p r i l

E

R p a t e l d

N O

T

FO

R C

O N

S

TR

U C

TI

O

N

P R

E L

IM

IN

A

R Y

D E

P A

R T

M E

T

V

Y

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

P-

UN

DE

R

W

AT

ER

L

AU

NC

H

TE

ST

F

AC

IL

IT

Y

N S

A

C

R A

N E

C R

A N

E

I N

D I A

N A

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

O V

O

U L D

V

I E

W

C T

F

C

O N

S T

R U

C T

I O

N

D

E T

A I L

S

CTF-C-506

AS NOTED

KM MD KM

4.00

2.50 3.062 1.278 0.669 0.760 0.228 0.313 0.352

1.968 3.500 1.336 0.834 1.187 0.707 0.664

A

XX

Y

Y

C

D

B

N.T.S.

A

XX

Y

Y

1"

C

D

B

"A" "B" "C" "D"

DIMENSIONS (IN)

AREA

IN.

I(IN. )S(IN. )I(IN. ) S(IN. )

4 3 4

Y-Y AXIS

1.516 0.539

0.611 1.161

4.00

2.50 3.125 1.250 0.625 0.748 0.233 0.289 0.353

1.845 3.500 1.625 0.718 1.190 0.560 0.690

"A" "B" "C" "D"

DIMENSIONS (IN)

AREA

IN. I(IN. )S(IN. )I(IN. ) S(IN. )

4 3 4

Y-Y AXIS

1.549 0.551

0.500 1.190

12"

3"

6"

0.120" NOM.

(11 GAUGE)

1"

14"

7"

0.120" NOM.

(11 GAUGE)

I A

H

O L

C

T

O

C

TYPE 1 STEEL U-POST PROPERTIES

TYPE 2 STEEL U-POST PROPERTIES

TYPE 1 STEEL

U-POST

TYPE 2 STEEL

U-POST

V E

R T

I C

S

T

L

E N

G

I A

H

O L

C

T

O

C

TOP POST

U-POST

TYPE 1

SOIL ANCHOR PLATE

TYPE 2

SOIL ANCHOR PLATE

TYPE 1

ANCHOR POST

ASSEMBLY

TYPE 2

ANCHOR POST

ASSEMBLY

I A

H

O L

C

T

O

C

WEIGHT

LBS. / FT.

X-X AXIS

WEIGHT

LBS. / FT.

X-X AXIS

8TH HOLE FROM THE TOP

TYPE 1 SOIL ANCHOR PLATE

TYPE 1 STEEL U-POST

13TH HOLE FROM THE TOP

TYPE 2 SOIL ANCHOR PLATE

TYPE 2 STEEL U-POST

STEEL U-POST SIGN

SUPPORTS

7/16" DIA. HOLES

7/16" DIA.

HOLES

NOTES:

1. PLACE SIGNS AT ALL CORNERS & EVERY 100' ALONG

PROPERTY BOUNDARY.

2. IN AREAS OUTSIDE THE LIMIT OF DISTURBANCE SHOWN ON

THE PLANS, INSTALL SIGNAGE WITHOUT THE BENEFIT OF

MOTORIZED VEHICLES. ACCESS SIGN LOCATIONS VIA FOOT

TRAFFIC ONLY. HAMMER SIGNS INTO PLACE. NO OTHER

DISTURBANCE IS PERMITTED.

3. METAL SIGNS WITH STEEL POST. SEE DETAIL REF. LTF-C-509/8.

12" 3000 PSI

CONCRETE RING

PRE-CAST OR

POURED IN PLACE

6" DENSE GRADED

AGGREGATE/AGGREGATE

BASE COURSE

6" CLASS "C"

CONCRETE (TYP.)

8"

1 1/2"

COVER AND CIRCULAR FRAME

MORTAR FRAME IN PLACE

PROPOSED GRADE

BRICK SHIM TO

GRADE (TYP.)

COARSE SAND

4"x4" TAPER TO 5"x5" x 30"

REINFORCED CONCRETE SURVEY

MONUMENT W/2" ENGRAVED

ALUMINUM MARKER CAP -

"NAVAL AIR WEAPONS STATION"

"SURVEY MONUMENT"

12" TYP.

COMPACTED

SUBGRADE

NOTES:

1. SURFACES ARE PRIMED WITH RUST & CORROSION RESISTANT, ZINC RICH

PRIMER W/5,000 HOUR SALT SPRAY PERFORMANCE.

2. WHERE ADJACENT TO ROLL-UP DOORS, ALIGN CENTER WITH DOOR JAMB.

6"

3/4" THICK STEEL PLATE

W/4 1/2" DIA. X 6" LONG

ANCHOR BOLTS

CONCRETE

PAD

18"

STEEL SAFETY YELLOW

WALL THICKNESS MIN 0.432"

18"

YELLOW HDPE

BOLLARD COVER

CONCRETE TO BE RAISED FOR

PROPER WATER RUN OFF

6" STEEL PIPE FILLED w/ CONC &

EMBEDDED IN CONC BASE. PAINT

HIGH VISIBILITY YELLOW.

PITCH AWAY FROM BOLLARD

PROPOSED SURFACE PER PLAN

PROVIDE EXPANSION JOINT MATERIAL

BETWEEN CONCRETE FOUNDATION AND

OTHER CONCRETE SURFACES

4,000 PSI AIR ENTRAINED CONCRETE

6x6x6 WELDED WIRE FABRIC (WWF)

COMPACTED SUBGRADE

NOTES:

1. BOLLARDS REQUIRED AS DEPICTED ON SITE PLAN DRAWINGS.

2. WHERE ADJACENT TO ROLL-UP DOORS, ALIGN CENTER WITH DOOR JAMB.

WHEEL STOP (TYP.)

4" AZURE BLUE

PAINTED STRIPING

(TYP.) ACCESSIBLE

SYMBOL (54"W x 60"H)

4" AZURE BLUE

PAINTED

STRIPING @ 12"

O.C. (TYP.)

8'-0" 8'-0"

20'

5'-4"

4'-4 1/2"

4" AZURE BLUE

PAINTED

STRIPING (TYP.)

1'-2"

NOTE:

1. CONCRETE WHEEL STOP IS 2'-2" FROM CENTER OF WHEEL STOP TO

EDGE OF CONCRETE.

3'-0"

PARKING

RESERVED

SUBSEQUENT OFFENSES

$ 250 MINIMUM AND/OR

UP TO 90 DAYS COMMUNITY SERVICE

$ 250 FIRST OFFENSE

TOW AWAY ZONE

PENALTY

ACCESSIBLE

VAN

1'-0"

1/4" x 1/2" LG. PIN HD. BOLTS

WITH NUTS & LOCK WASHERS

AZURE BLUE LETTERS

WHITE BACKGROUND

AZURE BLUE

WHITE BACKGROUND

BLACK LETTERS

PENALTY

$ 250 FIRST OFFENSE

SUBSEQUENT OFFENSES

$ 250 MINIMUM AND/OR

UP TO 90 DAYS COMMUNITY SERVICE

TOW AWAY ZONE

R7-8

R7-8P

FIN. GRADE

A

B O

V E

G R

O U

N D

COMPACTED

SUBGRADE

12"

NOTE:

1. METAL SIGNS WITH STEEL POST. SEE DETAIL REF.

LTF-C-509/8.

BOUNDARY

1/4" x 1/2" LG. PIN HD.

BOLTS WITH NUTS &

LOCK WASHERS

1'-6"

3" BLACK LETTERS

WHITE BACKGROUND

GRADE

CTF

MARKER

COMPACTED SUBGRADE

RESTRICTED

1/4" x 1/2" LG. PIN HD.

BOLTS WITH NUTS &

LOCK WASHERS

WARNING

AREA

KEEP OUT

AUTHORIZED

2'-0"

PERSONNEL

ONLY

3" BLACK LETTERS

WHITE BACKGROUND

B1

SURVEY MONUMENT DETAIL

NOT TO SCALE

A1

SURFACE MOUNTED BOLLARD DETAIL 1

NOT TO SCALE

B2

LTF BOUNDARY MARKER SIGN DETAIL

NOT TO SCALE

A2

CONCRETE EMBEDDED BOLLARD DETAIL 2

NOT TO SCALE

A3

NOT TO SCALE

ACCESSIBLE PARKING SIGN

DETAILS (R7-8, R7-8P)

A5

ACCESSIBLE STALL MARKING

NOT TO SCALE

B4

STEEL POSTS, POST CLIPS, SPACING, ETC.

NOT TO SCALE

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

stmurphy stmurphy

M

E

C p w w o r k i n g g b n a d a x e s h p d C

T F

C d

Y O

M

E

C

T F

C

O

T T

E D

T u e s d a y

A p r i l

E

R p a t e l d

N O

T

FO

R C

O N

S

TR

U C

TI

O

N

P R

E L

IM

IN

A

R Y

D E

P A

R T

M E

T

V

Y

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

P-

UN

DE

R

W

AT

ER

L

AU

NC

H

TE

ST

F

AC

IL

IT

Y

N S

A

C

R A

N E

C R

A N

E

I N

D I A

N A

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

O V

O

U L D

V

I E

W

C T

F

C

O N

S T

R U

C T

I O

N

D

E T

A I L

S

CTF-C-507

AS NOTED

KM MD KM

NOTES:

1. CONCRETE SHALL BE 4,000 PSI.

2. BUTT DIAMETER OF FLAG POLE SHALL BE 3" WHILE TOP DIAMETER IS 1 7/8".

C

L R

PLAN VIEW

0'-4"

LAP (MIN.)

ANCHOR BOLTS AND BASE PLATE AS

REQUIRED BY POLE MANUFACTURER

3/4" NON-SHRINK GROUT PACKED UNDER

POLE BASE TO ENSURE FULL CONTACT WITH

FOOTING AND PREVENT LOOSENING OF LEVELING

NUT. SLOPE TOP TO OUTSIDE EDGE OF FOOTING.

PROVIDE 3/8" WIDE x 3/8" DEEP CHANNEL

THROUGH GROUT FOR DRAINAGE FROM POLE

INTERIOR.

3~#3 TIES @ 3" O.C.

AT ANCHOR BOLTS

SLOPE AWAY

FROM BASE PLATE

#3 TIES @ 12" O.C. MAX.

36" DIAMETER CAST-IN

PLACE CONCRETE

FOUNDATION

#3 TIES

W/LAPPING

7~#8 VERTICALS

7~#8

VERTICALS

LEVELING NUT

AND WASHER

POLE BASE COVER

15'-0" HIGH FLAG POLE

A

L U

M I N

M

L

E

E

X P

O S

I G

H T

ANODIZED SPUN

ALUMINUM BALL, FLUSH SEAM

SINGLE SHEAVE TRUCK

CAST ALUMINUM REVOLVING

NON-FOULING TYPE

ONE (1) SET

OF HALYARDS

9" CAST ALUMINUM CLEAT WITH

1/4"-20NC FLAT HEAD STAINLESS

STEEL SELF DRILLING SCREWS

TWO (2) SNAP HOOKS,

WITH NEOPRENE COVERS

7' TAPERED ALUMINUM

POLE (15' EXPOSED)

FINISHED GRADE

B4

15' TAPERED ALUMINUM FLAG POLE

NOT TO SCALE

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

stmurphy stmurphy

M

E

C p w w o r k i n g g b n a d a x e s h p d C

T F

C d

Y O

M

E

C

T F

C

O

T T

E D

T u e s d a y

A p r i l

E

R p a t e l d

N O

T

FO

R C

O N

S

TR

U C

TI

O

N

P R

E L

IM

IN

A

R Y

D E

P A

R T

M E

T

V

Y

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

P-

UN

DE

R

W

AT

ER

L

AU

NC

H

TE

ST

F

AC

IL

IT

Y

N S

A

C

R A

N E

C R

A N

E

I N

D I A

N A

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

O V

O

U L D

V

I E

W

C T

F

C

O N

S T

R U

C T

I O

N

D

E T

A I L

S

CTF-C-508

AS NOTED

KM MD KM

12"

V A

R I A

B L

E

P

I

D

V

A

R

I

A

B

L

E

COMPACTED AGGREGATE, NO. 53, BASE

6" LIQUID POLYMER EMULSION

STABILIZER FOR VEHICLE

TRAVEL AREA ON SURFICIAL

SOIL FOR NON-PAVED AREAS

EXISTING TO BE

SAWCUT FULL DEPTH

(BOTH SIDES)

EXISTING GROUND

PAVED

AREA

UNPAVED AREA/COMPACTED EARTH

TRAVEL AREA

12"

INITIAL BACKFILL

MATERIAL

COMPACTED FILL TO 95%

MODIFIED PROCTOR

DENSITY ASTM D-1557

EXISTING

PAVEMENT

PAVED

AREA

NON-PAVED AREA

18"

(WATER SYSTEM, SANITARY SEWER SYSTEM,

ELECTRIC/COMMUNICATION SYSTEMS)

NOTES:

1. PROVIDE WARNING TAPE AND DETECTION WIRE PER PROJECT SPECIFICATIONS.

2. SEE CONCRETE ENCASEMENT DETAIL FOR ELECTRIC/COMMUNICATION CONDUIT WITHIN

THIS TRENCH.

D

PAVED AREAS

SEE BITUMINOUS PAVEMENT

DETAIL REF. LTF-C-508/2

NON-PAVED AREAS

COMPACT TO 95% MODIFIED

PROCTOR DENSITY

(ASTM D-1557)

4" PLUS 1/2 PIPE DIA. MIN.

INITIAL BACKFILL MATERIAL

UNDISTURBED EARTH

(NOTE 2)

A P

P R

O V

X C

A V

A T

M

T

E R

I A

L S

E M

B E

D M

E N

T

Z O

N E

N

O T

E

B A

C K

F I L

L

Z

O N

E

FINISHED GRADE

PIPE

D.D.

NOTES:

1. PLACE EMBEDMENT ZONE BACKFILL BY HAND IN 6-INCH LIFTS ON BOTH

SIDES OF PIPE. COMPACT TO 95% MAX. DRY DENSITY IN ACCORDANCE

WITH ASTM D-1557.

2. IF UNSUITABLE SOIL MATERIALS ARE ENCOUNTERED, REMOVE AND REPLACE WITH 12 3

INCHES ADDITIONAL BEDDING OR AS DIRECTED BY CONTRACTING OFFICER.

MIN. MIN.

12" 12"

COMPACTED AGGREGATE, NO. 53,

BASE

SAWCUT 18" (TYP.)

FOR PAVEMENT

SWALE NO.

A B

X' X'

'B'

UNDISTURBED

SOIL/COMPACTED FILL PER

PROJECT SPECIFICATIONS

B - MIN. DEPTH

MAX. SLOPE

FINISHED GRADE

'A'

NOTE:

1. SEE DRAINAGE & UTILITY PLANS FOR SWALE SIZE & LOCATION

G

R

O

U

R

F

A

C

E

B

U

I L

D

I

G

C

A

D

E

DOWNSPOUT (ALSO

LEADER OR CONDUCTOR)

WALL BRACKET

ELBOW

CONCRETE

SPLASH

BLOCK

3"

VEHICLE TRAVEL

AREA

L2

W1

L1

W2

D d50=24"

48" THICK W/ FILTER

FABRIC

OUTLET

SH #1 (HW #1)

W1 W2 D TH d50

(ft.) (ft.) (ft.) (ft.) (In.) (In.) (In.)

X

FLOW

HEAD WALL OR

WALL REF.

LTF-C-515

PLAN

3:1 3:1

SEE SITE PLAN FOR PIPE

ORIENTATION AND SIZE

SECTION B-B

L1 L2 PIPE SIZE

(In.)

TH

B

LTF-C-511 LTF-C-511

FILTER FABRIC

SH #2 (HW #2)

X 24

30"

9" 9"

NOTE:

1. SEWER CLEANOUTS REQUIRED AT ALL

BENDS, CHANGES IN SLOPE AND AT

BUILDING EXIT.

BRASS PLUG

GRADE

SEE PLAN FOR

MATERIAL

CALTRANS STANDARD

CLASS II AGGREGATE

BASE COURSE

4000 PSI CONCRETE ON

COMPACTED SUBGRADE

COMPACTED SUBGRADE

HDPE PIPE

90° ELBOW

12"

CAST IRON COVER & CIRCULAR FRAME

SEE BITUMINOUS PAVEMENT DETAIL REF.

LTF-C-508/2

X

X

X

X

X

X

X

X

X

X

X

X

C1

TYPICAL TRENCH, STORM SEWER SYSTEM

NOT TO SCALE

A1

UTILITY TRENCH AND BEDDING DETAIL

NOT TO SCALE

C3

FLARED END SECTION

NOT TO SCALE

B3

SWALE DETAIL

NOT TO SCALE

C4

PREFORMED SCOUR HOLE

NOT TO SCALE

B4

ROOF DRAIN AND SPLASH BLOCK DETAIL

NOT TO SCALE

A4

SEWER CLEANOUT DETAIL

NOT TO SCALE

DIA. WALL A

B

MIN.

C

MIN.

D E

12" 2" 4" 4'-0" 6' 2'-0"

15"

18"

6"

9"

3'-10"

3'-10"

2"

2 "

6'

6'

2'-6"

3'-0"

18"

18"

18"

DIMENSIONS

B

C

A

E

PLAN VIEW

SECTION A-A

END VIEW

8"

WALL

DIA.

A A

DIA.

WALL

6"

D

WALL +6"

D

DIA.

E

WALL

TOE WALL

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

stmurphy stmurphy

M

E

C p w w o r k i n g g b n a d a x e s h p d C

T F

C d

Y O

M

E

C

T F

C

O

T T

E D

T u e s d a y

A p r i l

E

R p a t e l d

N O

T

FO

R C

O N

S

TR

U C

TI

O

N

P R

E L

IM

IN

A

R Y

D E

P A

R T

M E

T

V

Y

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

P-

UN

DE

R

W

AT

ER

L

AU

NC

H

TE

ST

F

AC

IL

IT

Y

N S

A

C

R A

N E

C R

A N

E

I N

D I A

N A

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

O V

O

U L D

V

I E

W

C T

F

C

O N

S T

R U

C T

I O

N

D

E T

A I L

S

CTF-C-509

AS NOTED

KM MD KM

24" (MIN.) THICK

BIORETENTION

SOIL MEDIA

EXISTING SOIL SUBGRADE,

TILLED OR "RIPPED" 12"

DEEP BEFORE BACKFILLING

4" Ø SCHEDULE 40 PVC OR SDR 35

PERFORATED PIPE, 3/8" Ø HOLES, TWO

SIDES, FACING DOWN, 2" OFF BOTTOM

FILTER FABRIC

(SIDES ONLY)

2" THICK MULCH

SLOPE VARIES, SEE

GRADING PLAN (TYP.)

6" THICK SAND (ASTM C-33

FINE AGGREGATE)

6" THICK 3/8" Ø GRAVEL

(ASTM C-33 NO. 8)

6" THICK 3/4" Ø GRAVEL

(ASTM C-33 NO. 6 OR 67)

INVERT AS SHOWN

ON PLANS

CLEANOUT/OBSERVATION

WELL, 5' FROM

CENTER OF INLET

NOTE:

ALL SAND AND GRAVEL TO BE NATURAL, UNCRUSHED.

VEGETATION NOT SHOWN FOR CLARITY. BOTTOM OF BASIN TO BE PLANTED WITH SWAMP MILKWEED (ASCLEPIAS INCARNATE) AT 2' CENTERS

(#1 CONTAINER).

THE PLANTING SOIL MUST BE A SANDY LOAM OR LOAMY SAND CONTAINING A MINIMUM OF 60 PERCENT SAND, BY VOLUME. THE CLAY

CONTENT MUST BE LESS THAN 10 PERCENT BY VOLUME. A SATURATED HYDRAULIC CONDUCTIVITY OF AT LEAST 2.0 FEET PER DAY (1.0 INCHES

PER HOUR) IS REQUIRED. THE SOIL MUST BE FREE OF STONES, STUMPS, ROOTS, OR OTHER WOODY MATERIAL OVER 1 INCH IN DIAMETER AND

MUST BE FREE OF BRUSH OR SEEDS FROM NOXIOUS WEEDS, SUCH AS JOHNSON GRASS, MUGWORT, NUTSEDGE AND CANADIAN THISTLE.

PLACEMENT OF THE PLANTING SOIL MUST BE IN LIFTS OF 12 TO 18 INCHES, LOOSELY COMPACTED (RUBBER WHEELED HEAVY EQUIPMENT AND

MECHANICAL TAMPING DEVICES ARE NOT RECOMMENDED FOR COMPACTION). THE PH RANGE MUST BE BETWEEN 5.2 AND 8.0. ORGANIC

MATTER MUST BE BETWEEN 1.5 AND 5%. MAGNESIUM, PHOSPHORUS AND POTASSIUM MUST BE APPLIED AT MINIMUM RATES OF 35, 75 AND 85

LBS. PER ACRE.

THE MULCH LAYER MUST BE STANDARD LANDSCAPE STYLE, SINGLE OR DOUBLE SHREDDED HARDWOOD MULCH. THE MULCH LAYER MUST BE

FREE OF OTHER MATERIALS, SUCH AS WEED SEEDS, SOIL, ROOTS, ETC.

WIDTH VARIES, SEE PLAN VIEW

INDOT TYPE "A" INLET

SEE PLAN FOR LOCATION

THREADED PLUG

EL. XXX.XX

EL. XXX.XX

SILL

EL. XXX.XX

XX" ORIFICE

XX" ORIFICE

PERFORATED

UNDERDRAIN

FROM BMP

BOTTOM OF BASIN

INDOT TYPE "A" INLET

B1 BIORETENTION BASIN - TYPICAL SECTION

NOT TO SCALE B4 COMPOSITE OUTLET STRUCTURE

NOT TO SCALE

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

stmurphy stmurphy

NOTES:

1. PRECAST REINFORCED CONCRETE METER PIT; HS-25 RATED LOADING.

2. FIXED LADDER IN ACCORDANCE WITH OSHA STANDARDS 29 CFR. STEEL REINFORCED

POLYPROPYLENE LADDER RUNGS TO BE INSTALLED.

3. LOCKABLE ACCESS HATCH W/FLUSH MOUNT LIFT HANDLE.

4. LOCATE REMOTE METERING DEVICE CLEAR OF ACCESS COVER OF THE PIT AND PER MANUFACTURER'S

RECOMMENDATIONS. REMOTE METERING DEVICE TO BE COMPATIBLE WITH EXISTING BASE METERING AND

REPORTING SYSTEM.

5. BACKFLOW PREVENTORS AT ALLBUILDINGS AND TAKEOFF POINTS.

6. SUPPORT VALVES, PIPING, METER AND STRAINER TO AGGREGATE BASE AS REQUIRED.

7. FILL ANNULAR SPACE BETWEEN WALLS AND SLEEVES WITH RICH CEMENT MORTAR AND

ANNULAR SPACE BETWEEN PIPE AND SLEEVE WITH MASTIC.

8. ACCESS HATCH TO BE PROVIDED IN THE DIMENSIONS INDICATED AND ADHERE TO THE FOLLOWING REQ:

8.1. HATCH SHALL BE ALUMINUM DOUBLE LEAF HINGED DOORS REINFORCED TO SUPPORT AAHSTO HS-25

WHEEL LOAD WITH A MAXIMUM DEFLECTION OF 1/150TH OF THE SPAN.

8.2. COVER SHALL BE

" ALUMINUM DIAMOND PATTERN.

8.3. FRAME SHALL BE

" EXTRUDED ALUMINUM WITH ANCHOR TABS AROUND THE PERIMETER FOR

ANCHORING IN PLACE BY CASTING INTO THE PRECAST VAULT STRUCTURE.

8.4. LIFTING MECHANISMS: MANUFACTURER SHALL PROVIDE THE REQUIRED NUMBER AND SIZE OF

COMPRESSION SPRING OPERATORS ENCLOSED IN TELESCOPIC TUBES TO PROVIDE SMOOTH, EASY, AND

CONTROLLED COVER OPERATION THROUGHOUT THE ENTIRE ARC OF OPENING AND TO ACT AS A CHECK

IN RETARDING DOWNWARD MOTION OF THE COVER WHEN CLOSING. SPRINGS AND SPRING TUBES SHALL

BE TYPE 316 STAINLESS STEEL.

8.5. A REMOVABLE EXTERIOR TURN/LIFT HANDLE WITH A SPRING LOADED BALL DETENT SHALL BE PROVIDED

TO OPEN THE COVERS AND THE LATCH RELEASE SHALL BE PROTECTED BY A FLUSH, GASKETED, REMOVABLE SCREW PLUG.

8.6. HARDWARE:

8.6.1. HINGES: HEAVY FORGED TYPE 316 STAINLESS STEEL HINGES, EACH HAVING A MINIMUM

" DIA.

TYPE 316 STAINLESS STEEL PIN, SHALL BE PROVIDED AND SHALL PIVOT SO THE COVER DOES

NOT PROTRUDE INTO THE CHANNEL FRAME.

8.6.2. COVERS SHALL BE EQUIPPED WITH A HOLD OPEN ARM THAT AUTOMATICALLY LOCKS THE COVERS

IN THE OPEN POSITION.

8.6.3. A TYPE 316 STAINLESS STEEL SNAP LOCK WITH FIXED HANDLE SHALL BE MOUNTED ON THE

UNDERSIDE OF THE COVER.

8.6.4. HARDWARE SHALL BE TYPE 316 STAINLESS STEEL THROUGHOUT.

8.6.5. HARDWARE EXPOSED WHEN COVER IS CLOSED SHALL BE TAMPER PROOF.

8.7. FINISHES: FACTORY FINISH SHALL BE MILL FINISH ALUMINUM WITH BITUMINOUS COATING APPLIED TO

THE EXTERIOR OF THE FRAME.

PLAN

A

LTF-C-513 LTF-C-513

4" OS&Y FLANGED GATE VALVE6"Ø AIR

VENT

4" COMPOUND METER

4" OS&Y FLANGED GATE VALVE

4" PVC

4" PLATE-TYPE STRAINER

3'x3' FRAME AND

ACCESS HATCH

HS-25 LOADING

REMOTE METERING

DEVICE

4" PVC

4" PVC

1 1/2"Ø DIA. STEEL REINFORCED

POLYPROPYLENE LADDER RUNGS @

12" O.C. (TYP.)

PRECAST METER PIT

(6'x4'x5')

WATERPROOF

COMPOUND

(ALL SIDES)

REMOTE METERING

DEVICE

12" COMPACTED

AGGREGATE, NO. 53,

BASE

6'-0"

7'-0"

6" (TYP)

6" DUCTILE IRON PIPE

SLEEVE OR SCH 40

STEEL WALL SLEEVE

(TYP.) SEE NOTE #7

UNDISTURBED

SOIL/COMPACTED

FILL PER

PROJECT

SPECIFICATIONS

12"x12" OPENING

THROUGH FLOOR

SECTION A-A

F I

M

E

C p w w o r k i n g g b n a d a x e s h p d C

T F

C d

Y O

M

E

C

T F

C

O

T T

E D

T u e s d a y

A p r i l

E

R p a t e l d

N O

T

FO

R C

O N

S

TR

U C

TI

O

N

P R

E L

IM

IN

A

R Y

D E

P A

R T

M E

T

V

Y

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

P-

UN

DE

R

W

AT

ER

L

AU

NC

H

TE

ST

F

AC

IL

IT

Y

N S

A

C

R A

N E

C R

A N

E

I N

D I A

N A

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

O V

O

U L D

V

I E

W

C T

F

C

O N

S T

R U

C T

I O

N

D

E T

A I L

S

CTF-C-510

AS NOTED

KM MD KM

6" PVC

6" GATE VALVE

C.I. VALVE BOX

M

I N

I M

U M

D E

P T

H

V

A R

I E

S

COMPACTED EARTH

TRAVEL AREA

12" TYPICAL

(VARIABLE)

36" MIN.

84" MAX.

CONNECTIONS AS SPECIFIED (1)

4-1/2"

(2) 2-1/2" TYP.

M

I N

M A

X

POROUS FILL

AROUND BARREL

POURED CONCRETE THRUST

BLOCK PER THRUST BLOCK

DETAIL

WATER MAIN

BEARING ON

UNDISTURBED

GROUND

POURED CONCRETE

THRUST BLOCK PER

THRUST BLOCK

DETAIL

TIE RODS (3/4" MIN.)

6" GRAVEL BEDDING

UNDER ALL VALVES

AND FITTINGS

BEARING ON

UNDISTURBED GROUND

1 CUBIC FOOT GRAVEL OR

BROKEN STONE DRAIN

CONSTRUCTION NOTES:

1. USE 2500 PSI CONCRETE FOR THRUST BLOCKS.

2. SIZE AND BEARING AREA FOR THRUST BLOCKS PER THRUST BLOCK DETAIL.

3. FINISH PAINTING SHALL BE RED OR AS DIRECTED BY THE CONTRACTING OFFICER. STENCIL

HYDRANT NUMBER AND MAIN SIZE ON THE HYDRANT BARREL USING BLACK STENCIL PAINT.

HYDRANT NUMBER TO BE PROVIDED BY THE CONTRACTING OFFICER.

4. SPECIAL HYDRANT ARRANGEMENTS OR SETTINGS TO BE DETAILED BY CONTRACTOR SUBJECT TO

CONTRACTING OFFICER'S APPROVAL.

5. USE MECHANICAL JOINT CONNECTIONS AND FITTINGS.

6. INSTALL BOLLARDS WHERE SHOWN ON PLANS AND AS PER DETAIL.

EDGE OF

COMPACTED

EARTH TRAVEL

AREA

CI LID MARKED

"WATER"

HYDRANT TO HAVE BREAK

SECTION

DRAIN PORTS MUST BE FREE OF

CONCRETE OR OTHER

PERMANENT OBSTRUCTIONS

T

Y

P

EDGE OF TRAVELWAY

NOTES:

1. USE WHERE SHOWN ON PLANS.

2. REFER TO FIRE HYDRANT DETAIL FOR HYDRANT INSTALLATION AND CONNECTION TO

FIRE MAIN.

3. REFER TO BOLLARD DETAIL FOR CONSTRUCTION.

3'-0"

8"

NOTES:

1. THRUST BLOCK BUILT AGAINST UNDISTURBED SOIL WITH ADEQUATE BACKING TO PREVENT MOVEMENT OF FITTING.

2. BEARING TABLE BASED ON 150 PSI STATIC PRESSURE PLUS 50 PSI WATER HAMMER AND 3000 PSF SOIL BEARING.

3. PIPE JOINTS AND BOLTS MUST BE ACCESSIBLE.

4. FELT WRAP AND TAPE FITTING FASTENER AREAS PRIOR TO THE CONCRETE THRUST BLOCK POUR TO ALLOW

FUTURE ACCESS TO THE FASTENERS AT THE JOINTS.

5. FOR THRUST BLOCKING ON VALVE, SEE TAPPING SLEEVE AND VALVE DETAIL.

6. THRUST BLOCKING DETAILS ARE SHOWN FOR TYPICAL INSTALLATIONS. IN SOME CASES ADDITIONAL RESTRAINT MAY BE REQUIRED. FOR

UNSTABLE SOIL CONDITIONS, SUBMIT RFI TO CONTRACTING OFFICER FOR THRUST BLOCK DIMENSIONS.

7. USE 2500 PSI PORTLAND CEMENT CONCRETE FOR THRUST BLOCKS.

8. WHERE PIPES ARE INSTALLED PARALLEL TO EACH OTHER, USE RESTRAINED JOINTS WHERE THRUST BLOCKS CANNOT BE USED.

B

BA

1'-3"

1'-0"

8"

6" dxe

C B

6"

6"

8"

5"

ACB

6"

6"

1'-0"

7"

8"

6"x4"

4"x2" e

A

B

8" 1'-1"

A

A d

A

B

8" 1'-6" d

B

1'-1"

C

R E

D U

C E

R S

AC

B

6"

6"

1'-4"

10"

ACB

6"

6"

1'-1" 1'-4"

Ad

4"

2"-2.5"

1'-1"

B

E N

D S

8"

A

2'-0" d

B

B

E N

D S

8"

B

A

1'-8" d d

B

2'-0"

C

B

6"

B

A C d

1'-8" 1'-6"

1'-0"

T E

P

S

B E

N D

S

MINIMUM SIZE OF 2500 PSI CONCRETE THRUST BLOCKS FOR WATER MAINS

CB

3'-7" 2'-3"

A

2'-3"

V

E R

T I C

A L

B

E N

D

10" 1'-5"

10" 2'-0" 1'-5"10" 2'-2"10"

2'-3" 3'-4"8" 2'-3"

2'-0" 1'-6"

10" 8"x6"

C

A

B

C

V

E R

T I C

A L

B

E N

D

5"8" 10" 7"

5'-6" 3'-7"

3'-7"

#4

REIN.

BAR

12" 2'-7"12" 2'-7"12"

2'-4" 4'-4"

3'-5" 4'-4"

12" 1'-9"

1'-9"10"

CB

Ad

4"

2"-2.5"

6"

C R

O S

S E

S

8"

10"

10" 8"

10" d

B

A

A

B

B

B

A

A

C

C

1'-0" 6"

4"x2

A1

METER PIT DETAIL

NOT TO SCALE

A2

FIRE HYDRANT BOLLARD LOCATION DETAIL

NOT TO SCALE

A5

FIRE HYDRANT

NOT TO SCALE

B3

THRUST BLOCKING

NOT TO SCALE

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

stmurphy stmurphy

M

E

C p w w o r k i n g g b n a d a x e s h p d C

T F

C d

Y O

M

E

C

T F

C

O

T T

E D

T u e s d a y

A p r i l

E

R p a t e l d

N O

T

FO

R C

O N

S

TR

U C

TI

O

N

P R

E L

IM

IN

A

R Y

D E

P A

R T

M E

T

V

Y

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

P-

UN

DE

R

W

AT

ER

L

AU

NC

H

TE

ST

F

AC

IL

IT

Y

N S

A

C

R A

N E

C R

A N

E

I N

D I A

N A

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

O V

O

U L D

V

I E

W

C T

F

C

O N

S T

R U

C T

I O

N

D

E T

A I L

S

CTF-C-511

AS NOTED

KM MD KM

A

LTF-C-514 LTF-C-514

SECTION A-A

2'-0"

8" THICK 4000 PSI CONCRETE PAD

TOP FLUSH WITH FINISH GRADE

TROWEL EDGE

EXPANSION JOINT

FILLER MATERIAL

2'-0"

VALVE BOX

4"

6"x6" W2.9xW2.9

WELDED WIRE FABRIC

TYPE "C" BEDDING, BROKEN STONE OR WASHED GRAVEL

MEETING REQUIREMENTS OF COURSE AGGREGATE SIZE

NO. 57 COMPACT TO 95% MODIFIED PROCTOR DENSITY

(ASTM D-1557)

FINISHED GRADE

WATER MAIN

2" PVC

4000 PSI CONCRETE PAD AROUND

VALVE BOX

SEE "VALVE BOX PAD DETAIL"

90° BEND

VALVE BOX

90° BEND W/

" DRAIN

HOLE

3000 PSI CONCRETE

THRUST BLOCK

BALL VALVE CURB

STOP

45° ELBOW

2" CORPORATION

ROTATED 45° FROM

BOTTOM OF MAIN

1 CUBIC YARD

" CLEAN STONE

SHUT

1 1/4" SQ.

BODY

6" DIAMETER

36"

3'

MINIMUM

5 1/8"

12" DIAMETER

STANDPIPE

(PAINTED BLACK)

STANDPIPE

(PAINTED RED)

STANDPIPE GROUND LINE

MARK

GROUND LINE OR

FINISHED GRADE

TAMPER SWITCH

(SEE DETAIL A)

PADLOCK PADLOCK

TAMPER

SWITCH

DETAIL A

S

H

U

T

4'Ø PRECAST

MANHOLE

CURB

STOP

4" WATER MAIN

12"W x 12"D CIRCULAR

CONCRETE FOOTING

(TYP)

UNDISTURBED SOIL/COMPACTED FILL PER PROJECT

SPECIFICATIONS

KEYWAY (TYP)

12" COMPACTED CLEAN

STONE

CONSTANT SLOPE

UP TO VALVE

" PER FOOT

DIELECTRIC

UNION

2" CORPORATION

2"Ø COPPER

TUBING TYPE 'K'

2" AIR RELEASE VALVE

W/MIN.

" ORIFICE

1" COPPER DRAIN LINE AND

CHECK VALVE

ADJUST FRAME TO

GRADE W/BRICK

COURSING (2) MAX

WATERTIGHT FRAME

AND COVER W/ LOCKING

COVER

2" ABOVE GRADE

WHERE OUTSIDE PAVED

AREA

M

I N

DEPTH OF COVER

3'-0" MINIMUM

2'-0"

SQUARE

2' X 2' X 8" THICK

CONCRETE PAD

SEE VALVE BOX PAD

DETAIL

TYPE "C" BEDDING, BROKEN STONE OR

WASHED GRAVEL MEETING REQUIREMENTS

OF COURSE AGGREGATE SIZE NO. 57

COMPACT TO 95% MODIFIED PROCTOR

DENSITY (ASTMD-1557).

WATER MAIN

TYPE "C" BEDDING, BROKEN STONE OR

WASHED GRAVEL MEETING REQUIREMENTS

OF COURSE AGGREGATE SIZE NO. 57

TOP OF WATER MAIN

FINISHED GRADE

VALVE BOX WITH COVER

(TO BE MARKED "WATER")

SET TOP FLUSH W/ GRADE SEE

VALVE BOX PAD DETAIL

12"

NOTES:

1. CONDUCT INSTALLATION OF TAPPING SLEEVE AND VALVE UNDER

"WET" CONDITIONS. MAINTAIN EXISTING MAINS IN SERVICE AT ALL TIMES

DURING TAPPING OR INSERTION.

2. CONCRETE THRUST BLOCK UNDER VALVES SHALL HAVE THE

SAME SOIL BEARING AREA AS A 45° ELBOW.

EXISTING 4" ASBESTOS

CEMENT PIPE

PLAN

ELEVATION

MECHANICAL JOINT

TAPPING VALVE

THRUST BLOCK POURED

AGAINST UNDISTURBED

SOIL

MECHANICAL JOINT

TAPPING SLEEVE

THRUST BLOCK POURED

AGAINST UNDISTURBED SOIL

#4 REIN. BAR

MECHANICAL JOINT

TAPPING VALVE

M

I N

4"Ø VENT PIPE

NOTES:

1. REFER TO TBD FOR BOLLARD SPACING DIMENSION.

2. REFER TO TBD OR BOLLARD CONSTRUCTION.

UNDISTURBED SOIL/COMPACTED FILL PER PROJECT

SPECIFICATIONS

UNDISTURBED SOIL/COMPACTED FILL PER

PROJECT SPECIFICATIONS

C1

AIR RELEASE VALVE MANHOLE DETAIL

NOT TO SCALE

A1

VALVE BOX DETAIL

NOT TO SCALE

C3

VALVE BOX PAD DETAIL

NOT TO SCALE

C4

TAPPING SLEEVE AND VALVE DETAIL

NOT TO SCALE

A3

BLOW OFF DETAIL

NOT TO SCALE

A4

POST INDICATOR VALVE

NOT TO SCALE

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

EXISTING GRADE

stmurphy stmurphy

M

E

C p w w o r k i n g g b n a d a x e s h p d C

T F

C d

Y O

M

E

C

T F

C

O

T T

E D

T u e s d a y

A p r i l

E

R p a t e l d

N O

T

FO

R C

O N

S

TR

U C

TI

O

N

P R

E L

IM

IN

A

R Y

D E

P A

R T

M E

T

V

Y

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

P-

UN

DE

R

W

AT

ER

L

AU

NC

H

TE

ST

F

AC

IL

IT

Y

N S

A

C

R A

N E

C R

A N

E

I N

D I A

N A

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

O V

O

U L D

V

I E

W

C T

F

C

O N

S T

R U

C T

I O

N

D

E T

A I L

S

CTF-C-512

AS NOTED

KM MD KM

L

'D' DIA.

HOLE

27"

'W'

18"

12"

'C'

'B'

'A'

'H'

RCP CMP CCP 'D' 'A' 'B' 'C' 'H' 'L' 'W'

12" 15" 15" 21" 30" 32" 12" 74" 48" 108"

15" - - 24" 30" 32" 12" 74" 48" 108"

18" - - 27" 30" 32" 12" 74" 48" 108"

21" 24" 24" 30" 30" 32" 12" 74" 48" 108"

24" 27" - 34" 30" 32" 12" 74" 48" 108"

30" 36" - 42" 36" 39" 9" 84" 72" 152"

36" 42" 36" 48" 42" 39" 9" 90" 72" 152"

42" 48" 42" 54" 42" 36" 12" 90" 96" 174"

27" 30" 30" 38" 30" 39" 9" 78" 72" 152"

RCP DRAINAGE PIPE.

SEE SITE PLAN FOR

PIPE ORIENTATION &

SIZE.

48" - - 58" 42" 36" 12" 90" 96" 175"

NOTES:

1. CONCRETE STRENGTH: 4000 PSI MIN. @ 28 DAYS

2. REINFORCING STEEL: CONFORMS TO ASTM A615 & A185

3. 1" CHAMFER ON EXPOSED EDGES.

4. ELEVATION BETWEEN TOP OF WALL AND TOP OF PIPE FOR 24" PIPE

IS 10" AND FOR 48" PIPE IS 5".

18" MIN.

3'

8"

RCP DRAINAGE PIPE

CONCRETE TOE

WALL

UNDISTURBED

SOIL/COMPACTED

FILL PER PROJECT

SPECIFICATIONS

COMPACTED AGGREGATE,

NO. 53, BASE

A

SECTION A VIEW

NOT TO SCALE

FINISHED GRADE

12" MIN.

NOTES:

1. SEWER CLEANOUTS REQUIRED AT ALL

BENDS, CHANGES IN SLOPE AND AT BUILDING EXIT.

2. REFER TO LTF-C-511/2 FOR BEDDING REQUIREMENTS OF HDPE PIPE.

8"x12" PVC WYE

12"

12"

8" HDPE 45° ELBOW

(TYP.)

8" HDPE (TYP.)

12" HDPE (TYP.)

8" HDPE TEE AND/OR

FITTING AS REQUIRED

(TYP.)

8" HDPE PIPE FROM

DOWNSPOUT (TYP.)

8"8"

RIP-RAP

SEE PLAN

HEADWALL BACKFILL

REFER TO MFSB

PLUMBING PLANS FOR

CONTINUATION

A3

HEADWALL DETAIL

NOT TO SCALE

C4

LEADER COLLECTION SYSTEM DETAIL

NOT TO SCALE

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

stmurphy stmurphy

P-409 LAUNCH TEST FACILITY

NAVAL AIR WEAPONS STATION

NAWS CHINA LAKE, CA

COST: $10,000,000 **

ENGINEER

JACOBS

CONTRACTOR

CONTRACTOR FIRM

ST, LOUIS, MO

CITY AND STATE *

NAVAL FACILITIES ENGINEERING COMMAND

2ND LINE

COMING IN SUMMER xxx **

Supporting the Warfighter

NAVFAC

COMPONENT NAME (i.e. MID-ATLANTIC) ***

P-112 LAUNCH TEST FACILITY

INSTALLATION NAME

"KNOW SAFETY-

NO MISHAPS"

CONTRACTOR FIRM NAME

CITY AND STATE

PROJECT START DATE

DAYS SINCE LAST

LOST TIME ACCIDENT

TOTAL LOST TIME INJURIES

00-00-00

000 0

0 0

F I

M

E

C p w w o r k i n g g b n a d a x e s h p d C

T F

C d

Y O

M

E

C

T F

C

O

T T

E D

T u e s d a y

A p r i l

E

R p a t e l d

N O

T

FO

R C

O N

S

TR

U C

TI

O

N

P R

E L

IM

IN

A

R Y

D E

P A

R T

M E

T

V

Y

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

P-

UN

DE

R

W

AT

ER

L

AU

NC

H

TE

ST

F

AC

IL

IT

Y

N S

A

C

R A

N E

C R

A N

E

I N

D I A

N A

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

O V

O

U L D

V

I E

W

C T

F

C

O N

S T

R U

C T

I O

N

D

E T

A I L

S

CTF-C-513

AS NOTED

KM MD KM

4'-0"

GROUND LEVEL

NOTES:

1. PAINT ALL OTHER WOOD SURFACES WITH ONE COAT EXT. PRIMER AND TWO COATS GLOSS WHITE ENAMEL.

2. ALL LETTERING SHALL BE EVENLY SPACED.

3. LETTER STYLE, 'ARIAL', COLOR 'DARK BLUE'. TYPICAL FOR ALL LETTERING.

* -ABBREVIATE STATE

** -CONFIRM USE WITH CONTRACTING OFFICER

*** -VERIFY NAME WITH CONTRACTING OFFICER.

VERIFY W/ CONTRACTING OFFICER IF

PROJECT IS AN ARRA PROJECT. FOR ARRA

PROJECTS, ADD SIGNAGE AT TOP OF SIGN.

MITERED CORNER

4X4 PRESSURE TREATED POST; COLOR:

'DARK BLUE', TYP.

2" LETTERING CENTERED (ITALICIZED)

PAINTED FIELD; COLOR, 'WHITE'

3" LETTERING CENTERED

2" LETTERING CENTERED

2.5" LETTERING CENTERED

(ITALICIZED)

2" LETTERING CENTERED

2" LETTERING CENTERED

PAINTED 3.5" STRIPE; COLOR, 'DARK

BLUE'

2.5" LETTERING

CENTERED

9.5"x11.25" NAVFAC LOGO AVAIL:

https://portal.navfac.navy.mil/ portal/page?_pageid=

181,3465071&_dad=portal&_ schema=PORTAL

PAINTED 3.5" STRIPE;

COLOR, 'DARK BLUE'

PAINTED 3.5" STRIPE;

COLOR, 'DARK BLUE'

PAINTED FIELD;

COLOR, 'WHITE'

2.5" LETTERING

CENTERED

4x4 PRESSURE

TREATED POST

BEYOND; COLOR:

'WHITE'

GROUND LEVELGROUND LEVEL

4'-0"

3" 3" 3"

3" DARK BLUE LETTERING,

CENTERED

2'-4

GREEN FIRST AID LOGO

" HDO PLYWOOD

PAINTED GLOSS WHITE

3" DARK BLUE LETTERING,

RIGHT JUSTIFIED

REPLACEABLE NUMBERS MOUNTED ON

WHITE ALUMINUM PLATE

1 2

1 2

1 2

1 2

1 2

1 2

" DARK BLUE LETTERING,

LEFT JUSTIFIED

4x4 PRESSURE TREATED POSTS

COLOR: WHITE

NOTES:

1. PAINT ALL OTHER WOOD SURFACES WITH ONE COAT EXT. PRIMER AND TWO COATS GLOSS WHITE ENAMEL.

2. ALL LETTERING SHALL BE EVENLY SPACED.

3. LETTER STYLE, 'ARIAL', COLOR 'DARK BLUE'. TYPICAL FOR ALL LETTERING.

* -ABBREVIATE STATE

** -CONFIRM USE WITH CONTRACTING OFFICER

*** -VERIFY NAME WITH CONTRACTING OFFICER.

A1

PROJECT SAFETY PERFORMANCE SIGNBOARD

SCALE: 3/4" = 1'-0"

A4

PROJECT IDENTIFICATION SIGNBOARD

SCALE: 3/4" = 1'-0"

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

stmurphy stmurphy

M

E

C p w w o r k i n g g b n a d a x e s h p d C

T F

C d

Y O

M

E

C

T F

C

O

T T

E D

T u e s d a y

A p r i l

E

R p a t e l d

N O

T

FO

R C

O N

S

TR

U C

TI

O

N

P R

E L

IM

IN

A

R Y

D E

P A

R T

M E

T

V

Y

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

DES DRW CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

P-

UN

DE

R

W

AT

ER

L

AU

NC

H

TE

ST

F

AC

IL

IT

Y

N S

A

C

R A

N E

C R

A N

E

I N

D I A

N A

JACOBS ENGINEERING GROUP INC.

412 MT. KEMBLE AVENUE

MORRISTOWN, NJ 07960

PHONE: (973) 267-0555

O V

O

U L D

V

I E

W

C T

F

C

O N

S T

R U

C T

I O

N

D

E T

A I L

S

CTF-C-514

AS NOTED

KM MD KM

SCALE: 3"=1'-0"

PLAN SECTION

SCALE: 3"=1'-0"

SECTION AT TOP

FRONT BACK

NOT TO SCALE

ISO VIEW

SCALE: 1/2"=1'-0"

NOTES:

1. POSTS AND BRACES SHALL BE PRESSURE TREATED.

2. ALL FASTENERS SHALL BE ZINC COATED.

3. BRACING IS REQUIRED IN ALL SOIL CONDITIONS AND

HIGH WIND ENVIRONMENTS.

TOP VIEW

SCALE: 1/2"=1'-0"

SIDE VIEW

SECTION AT RENDERING FRAME

FRONT

BACK

4"x4" PRESSURE TREATED POST; COLOR:

'WHITE', TYP. ***NOTE POSITION OF POST

BEHIND SIGNBOARD***

10 PENNY GALVANIZED FINISHING NAILS AT 8"

O.C. VERTICALLY; TOE NAIL BLUE POST, FLUSH

NAIL WHITE POST

BRACE BEYOND

3" WOOD SCREWS, BRACE TO POST

1" DEEP ROUTED GROOVE, 3/4"

WIDE

4"x4" PRESSURE TREATED

POST; COLOR: 'DARK BLUE', 4

SIDES

3/4" PLYWOOD PANEL

CAP ABOVE

ARRA ADDITIONAL SIGN- REFER TO PLATES 8

AND 9 FOR SIGNAGE AND DETAILS

4"x4" PRESSURE TREATED CAP; COLOR: 'DARK

BLUE', 4 SIDES

1" DEEP ROUTED GROOVE, 3/4" WIDE

10 PENNY GALVANIZED FINISHING NAILS AT 8"

O.C. HORIZONTALLY, TOE NAILED

45° CHAMFER WHITE POST BEHIND SIGN

NOTE LOCATION OF POST BEHIND SIGN BOARD

POST BEYOND

2"x6" PRESSURE TREATED

BRACE

3/4" BOLT EACH BRACE

4"x4" PRESSURE TREATED CAP, ABOVE

4"x4" PRESSURE TREATED POST;

COLOR: 'WHITE', TYP. ***NOTE

POSITION OF POST BEHIND

SIGNBOARD***

3/4" PLYWOOD

4"x4" PRESSURE TREATED POST;

COLOR: 'DARK BLUE', TYP.

VERIFY W/ CONTRACTING OFFICER IF

PROJECT IS AN ARRA PROJECT. FOR

ARRA PROJECTS, ADD SIGNAGE AT TOP

OF SIGN. SEE PLATES 8 AND 9 FOR

SIGNAGE AND DETAILS.

4"x4" PRESSURE TREATED CAP;

COLOR: 'DARK BLUE', TYP.

4"x4" PRESSURE TREATED POST;

COLOR: 'WHITE', TYP. ***NOTE

POSITION OF POST BEHIND

SIGNBOARD***

4"x4" PRESSURE TREATED POST

BEYOND; COLOR: 'DARK BLUE', TYP.

3" WOOD SCREWS

2"x6" PRESSURE TREATED BRACE

3/4" BOLT EACH BRACE

2"x4" PRESSURE TREATED BRACE

4"x4" PRESSURE TREATED POST; BEYOND

3/4" PLYWOOD PANEL

SLOPE TOP AT SILL

3/4"x1-1/2" WOOD TRIM SET IN BED OF

SEALANT; COLOR, 'DARK BLUE'

1-1/4" WOOD SCREW, AS NEEDED

CAULK, ALL AROUND

4"x4" PRESSURE TREATED POST; BEYOND

3/16" PLEXIGLASS

CAULK, ALL AROUND

SLOPE TOP AT SILL

1-1/4" WOOD SCREW, AS NEEDED

3/4"x1-1/2" WOOD TRIM SET IN BED OF

SEALANT; COLOR, 'DARK BLUE'

3/4" PLYWOOD PANEL

B1

PROJECT IDENTIFICATION SIGNBOARD SUPPORT DETAILS

SCALE: AS SHOWN

A1

PROJECT IDENTIFICATION SIGNBOARD SECTION

SCALE: 6"=1'-0"

B4

PROJECT…

This is the start of the file's text. The full file is on GovTribe.