J-1502000-03_Rev_YRKT-CAX__INVENTORY.xlsx
XLSX spreadsheet 22 KB Posted
- Solicitation number
- N4008518R9772
About this file
J-1502000-03_Rev_YRKT-CAX__INVENTORY.xlsx
View the file
Other files
| File | Type | Posted |
|---|---|---|
| N40085-18-R-9772-0004.pdf | ||
| J-0200000-07_-_SERVICE_PROVIDER_INFORMATION_v1_-_2013-07-07.xlsx | XLSX spreadsheet | |
| N40085-18-R-9772-0003.pdf | ||
| J-1502000-03_Rev_Norfolk_Naval_Shipyard_Inventory.xlsx | XLSX spreadsheet | |
| UN_PRICED_Rev_ELINs_Facility_Investment_ver_2.4.xls | XLS spreadsheet | |
| N40085-18-R-9772-0002.pdf | ||
| Site_Visit_attendees.pdf | ||
| AMENDMENT_0001.pdf | ||
| ATTACHMENT_A_-_CORPORATE_EXPERIENCE.docx | DOCX document | |
| ATTACHMENT_J_-_Facilities_Property_Inventory.docx | DOCX document | |
| Solicitation_N4008518R9772.pdf | ||
| ATTACHMENT_B_-_PPQ.docx | DOCX document |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
YORK-CAX
| BUILDING # | BUILDING AREA ENGLISH (SF) | LONG DESCRIPTION | TYPE | STEAM OR HOT WATER | BTUH, PPH, HP | FUEL | MAKE | MODEL | SERIAL# | YEAR | H/W | C/W | DUAL TEMP | GEOTHERMAL | COOLING TOWER | FUNDING SOURCE |
| CHEANN-CAD30 | 431,721.00 | BOILER, GAS FIRED | FIRE TUBE | HOT WATER | 896,000 BTU 360 HP | GAS | SMITH | 28HE-5 | 28HE-5-152338 | 2016 | X | NEMSCOM | ||||
| CHEANN-CAD108 | 8,234.00 | BOILER, GAS FIRED | HOT WATER | 399,000 BTUH 157HP | GAS | LAARS | NEOTHERM 399 | D1.14.03.00406 | 2013 | X | NAVELSG | |||||
| CHEANN-CAD108 | 8,234.00 | CHILLER, SCROLL, AIR COOLED | TRANE | CGAFC25EAEA1T0009 CAPACITY: 25 TONS | 4209001AG5A | 2005 | X | NAVELSG | ||||||||
| CHEANN-CAD114 | 7,850.00 | BOILER, GAS FIRED | FIRE TUBE | STEAM | 3,348 MBH | GAS | BURHHAM | 31-80-50-0-PF | 24420 | 1997 | X | CNRMA | ||||
| CHEANN-CAD119 | 5,023.00 | BOILER, GAS FIRED | HOT WATER | 362,000 BTUH 142 HP | GAS | BURNHAM | PV90450B | 64464739 | 1989 | X | CNRMA | |||||
| CHEANN-CAD236 | 11,029.00 | BOILER, LOW PRESSURE, GAS | FIRE TUBE | STEAM | 2,415 PPH | GAS | BURNHAM | 3P-70-50-0-PF | 72127 | 2004 | X | CNRMA | ||||
| CHEANN-CAD483 | 81,620.00 | BOILER, GAS FIRED | FIRE TUBE | STEAM | 2,451 PPH | GAS | HURST | NATIONAL BOILER # 1103 | S350-15-2 | 1991 | X | MSC | ||||
| CHEANN-CAD483 | 81,620.00 | BOILER, GAS FIRED | FIRE TUBE | STEAM | 2,451 PPH | GAS | HURST | NATIONAL BOILER # 1104 | S350-15-3 | 1991 | X | MSC | ||||
| CHEANN-CAD483 | 81,620.00 | COOLING TOWER, EVAPCO | EVAPCO | LSWE-4-519-Z | 1991 | X | MSC | |||||||||
| CHEANN-CAD483 | 81,620.00 | COOLING TOWER, EVAPCO | EVAPCO | LSWE-4-519-Z | 1991 | X | MSC | |||||||||
| CHEANN-CAD483 | 81,620.00 | CHILLER, SHELL AND TUBE HEAT EXCHANGER | TRANE | RECIPROCATING | X | MSC | ||||||||||
| CHEANN-CAD483 | 81,620.00 | CHILLER, SHELL AND TUBE HEAT EXCHANGER | TRANE | RECIPROCATING | X | MSC | ||||||||||
| CHEANN-CAD504 | 80,356.00 | BOILER,GAS FIRED | FIRE TUBE | HOT WATER | 2,100,000 BTU 825 HP | GAS | COLUMBIA BOILER | NATIONAL BOILER # 147007 | MPH-50 | 1991 | X | NEMSCOM | ||||
| CHEANN-CAD564 | 15,585.00 | BOILER, GAS FIRED | COIL | HOT WATER | 1,000,000 BTU 393 HP | GAS | LAARS | MIGHTY THERM2 | C14256204 | 2016 | X | NEMSCOM | ||||
| CHEANN-CAD618 | 39,039.00 | BOILER, GAS FIRED | COIL | HOT WATER | 843,000 BTU 331 HP | GAS | LOCHINVAR | KNIGHT XL - KBN800 | B10H10124601 | 2012 | X | CNRMA | ||||
| CHEANN-CAD618 | 39,039.00 | CLOSED LOOP GEOTHERMAL | EVAPCO | COOLING TOWER NOT BEING USED,GEOTHERMAL USAGE ONLY | 2011 | X | CNRMA | |||||||||
| CHEANN-CAD622 | 26,536.00 | BOILER, GAS FIRED | FIRE TUBE | HOT WATER | 1,350,000 BTU 531 HP | GAS | FULTON | PULSE-PHW750 | NATIONAL BOILER # 114713 | 2012 | X | CNRMA | ||||
| CHEANN-CAD622 | 26,536.00 | BOILER, GAS FIRED | FIRE TUBE | HOT WATER | 1,350,000 BTU 531 HP | GAS | FULTON | PULSE-PHW750 | NATIONAL BOILER # 114714 | 2012 | X | CNRMA | ||||
| CHEANN-CAD622 | 26,536.00 | COOLING TOWER, EVAPCO | EVAPCO | LSWE-4-519-Z | 2012 | X | CNRMA | |||||||||
| YORK-461 | 4,734.00 | BOILER, GAS FIRED | HOT WATER | 250,000 BTUH 98 HP | GAS | SMITH CAST IRON | 8 SERIES S/W 3 | D-2004-525P | 2004 | X | CNRMA | |||||
| YORK-476 | 173,565.00 | BOILER, GAS FIRED | Water Tube | HOT WATER | 1,445,000 BTU 568 HP | GAS | LOCKINVAR | SBN-1500 | F09H10102881 | 2008 | X | CNRMA | ||||
| YORK-476 | 173,565.00 | BOILER, GAS FIRED | Module | HOT WATER | 1,445,000 BTU 568 HP | GAS | LOCKINVAR | SBN-1500 | F09H10102875 | 2008 | X | CNRMA | ||||
| YORK-476 | 173,565.00 | CHILLER, SCROLL, AIR COOLED | YORK | YLAA0156HE46XCA CAPACITY: 145 TONS | SNXM160110 | 2012 | X | CNRMA | ||||||||
| YORK-476 | 173,565.00 | CHILLER, SCROLL, AIR COOLED | YORK | YLAA0156HE46XCA CAPACITY: 145 TONS | SNXM160080 | 2012 | X | CNRMA | ||||||||
| YORK-480 | 60,240.00 | BOILER, GAS FIRED | HOT WATER | 139,100 BTU 55 HP | OIL | WEIL-MCLAIN | CGA-6-PIDN | CP7563453 | 2017 | X | CNRMA | |||||
| YORK-704 | 17,790.00 | BOILER, GAS FIRED | HOT WATER | 280,00 BTU 110 HP | GAS | BRYAN | DR350-W-FDG | 900241 | 2004 | X | CNRMA | |||||
| YORK-1348 | 7,167.00 | BOILER, GAS FIRED | Cast Iron | HOT WATER | 991,000 BTU 389 HP | GAS | WEIL-MCLAIN | 3/20/00 | CP5451500 | 2006 | X | INDIAN HEAD | ||||
| YORK-1595 | 59,220.00 | BOILER, GAS FIRED | FIRE TUBE | HOT WATER | 677,000 BTU 266 HP | GAS | HURST BOILER | FIRE TUBE | S400-30-3M | 2004 | X | CNRMA | ||||
| YORK-1595 | 59,220.00 | BOILER, GAS FIRED | FIRE TUBE | HOT WATER | 3,200,00 BTU 1258 HP | GAS | HURST BOILER | FIRE TUBE | FB67-30-3M | 2004 | X | CNRMA | ||||
| YORK-1595 | 59,220.00 | CHILLER, SCREW, AIR COOLED | TRANE | CGAM 060F2L02 CAPACITY: 60 TONS | U14H43692 | 2015 | X | CNRMA | ||||||||
| YORK-1595 | 59,220.00 | CHILLER, CGAM, AIR COOLED | TRANE | RTAA1254XK01A3D0AB CAPACITY: 125 TONS | U99EO8971 | 1999 | X | CNRMA | ||||||||
| YORK-1794 | 43,790.00 | BOILER, GAS FIRED | FIRE TUBE | HOT WATER | 1,000,000 BTU 393 HP | GAS | FULTON | PWH-1000 | 1001 | 2006 | X | NOSTRA | ||||
| YORK-1794 | 43,790.00 | BOILER, GAS FIRED | FIRE TUBE | HOT WATER | 1,000,000 BTU 393 HP | GAS | FULTON | PWH-1000 | 1002 | 2006 | X | NOSTRA | ||||
| YORK-1794 | 43,790.00 | CHILLER, SCREW, AIR COOLED | TRANE | RTAA1004XT01A3LOGANB - CAPACITY: 100 TONS | U0GL60763 | 1999 | X | NOSTRA | ||||||||
| YORK-1794 | 43,790.00 | CHILLER, SCREW, AIR COOLED | TRANE | RTAAXQ01A3DOGANB CAPACITY: 120 TONS | U04F06420 | 2004 | X | NOSTRA | ||||||||
| YORK-1806 | 18,100.00 | BOILER, GAS FIRED | FIRE TUBE | HOT WATER | 1,289,000 BTU 507 HP | GAS | BURNHAM | 4FW15440GOPF | 24819 | 2007 | X | CNRMA | ||||
| YORK-1806 | 18,100.00 | CHILLER, SCREW, AIR COOLED | TRANE | RTAA070AY01A300BD CAPACITY: 70 TONS | U98D09512 | 1998 | X | CNRMA | ||||||||
| YORK-1807 | 35,202.00 | BOILER, GAS FIRED | COIL | HOT WATER | 500,000 BTU 197 HP | GAS | LOCKINVAR | AWN-501-PM | 172910-684-6272 | 2017 | X | MARFORCOM | ||||
| YORK-1807 | 35,202.00 | BOILER, GAS FIRED | COIL | HOT WATER | 500,000 BTU 197 HP | GAS | LOCKINVAR | AWN-501-PM | 172910-684-6271 | 2017 | X | MARFORCOM | ||||
| YORK-1816 | 51,106.04 | BOILER, GAS FIRED | FIRE TUBE | HOT WATER | 1,400,000 BTU 550 HP | GAS | FULTON | EDR-1500 | 121629 | 2017 | X | CNRMA | ||||
| YORK-1816 | 51,106.04 | BOILER, GAS FIRED | FIRE TUBE | HOT WATER | 5,230,000 BTU 2055 HP | GAS | CLEVER BROOKS | CB-100-125 | L-85570 | 1997 | X | CNRMA | ||||
| YORK-1816 | 51,106.04 | CHILLER, SCROLL, AIR COOLED | TRANE | CGRAM CAPACITY: 90 TONS | 2018 | X | CNRMA | |||||||||
| YORK-1816 | 51,106.04 | CHILLER, SCROLL, AIR COOLED | TRANE | CGRAM CAPACITY: 90 TONS | 2018 | X | CNRMA | |||||||||
| YORK-1816 | 51,106.04 | CHILLER, SCROLL, AIR COOLED | TRANE | CGRAM CAPACITY: 90 TONS | 2018 | X | CNRMA | |||||||||
| YORK-1833 | 25,125.00 | BOILER, GAS FIRED | FIRE TUBE | STEAM | 1,035 PPH | GAS | HURST BOILER | LPE-G-30-15 | LPE-132.515/30-28 | 2017 | X | CNRMA | ||||
| YORK-1868 | 6,552.00 | BOILER, GAS FIRED | CAST IRON | HOT WATER | 521, 000 BTU 204 HP | GAS | WEIL-MCLAIN | 7/31/01 | 550223127 | 1997 | X | CNRMA | ||||
| YORK-1959 | 79,822.00 | BOILER, GAS FIRED | WATER TUBE | HOT WATER | 1,500,000 BTU 590 HP | GAS | THERMAL-SOLUTIONS | EVCA1500BNI-VAB | 65299831 | 2011 | X | CNRMA | ||||
| YORK-1959 | 79,822.00 | BOILER, GAS FIRED | WATER TUBE | HOT WATER | 2,000,000 BTU 786 HP | GAS | THERMAL-SOLUTIONS | EVCA1500BNI-VAB | 65299856 | 2011 | X | CNRMA | ||||
| YORK-1959 | 79,822.00 | CHILLER, YORK, AIR COOLED | EVAPCO | CAPACITY: 120 TONS | X | CNRMA | ||||||||||
| YORK-1959 | 79,822.00 | CHILLER, YORK, AIR COOLED | EVAPCO | CAPACITY: 90 TONS, | X | CNRMA | ||||||||||
| YORK-1990 | 48,380.00 | BOILER, GAS FIRED | WATER TUBE | HOT WATER | 1,500,000 BTU 590 HP | GAS | FULTON | EDR-1500 | 4814-HFTC | 2018 | X | CNRMA | ||||
| YORK-1992 | 3,750.00 | BOILER, GAS FIRED | HOT WATER | 164,196 BTU 65 HP | OIL | WEIL-MCLAIN | CGA-6-PIDN | CP7567647 | 2017 | X | CNRMA | |||||
| YORK-2006 | 13,223.00 | BOILER, GAS FIRED | WATER TUBE | HOT WATER | 886,100 BTUH 348 HP | GAS | COLUMBIA BOILER | WL-90 | 127257 | 1989 | X | CNRMA | ||||
| YORK-2020 | 78,518.00 | BOILER, HOT WATER, GAS FIRED | HOT WATER | 1,477,000 BTU 580 HP | OIL | WEIL-MCLAIN | 88 SERIES 788 | CP7084173 | 2017 | X | CNRMA | |||||
| YORK-2021 | 11,532.00 | BOILER, HOT WATER, GAS FIRED | HOT WATER | 285,000 BTUH | LOCHINVAR | KHN285 | 16810489520 | 2017 | X | CNRMA | ||||||
| YORK-2062 | 21,600.00 | BOILER, GAS FIRED | COIL | HOT WATER | 500,000 BTU 196 HP | GAS | A.O. SMITH | LW-750-300 | M9741977 | 1999 | X | CNRMA | ||||
| YORK-2062 | 21,600.00 | BOILER, GAS FIRED | COIL | HOT WATER | 500,000 BTU 196 HP | GAS | A.O. SMITH | LW-750-300 | M9742209 | 1999 | X | CNRMA | ||||
| YORK-2062 | 21,600.00 | BOILER, GAS FIRED | COIL | HOT WATER | 500,000 BTU 196 HP | GAS | A.O. SMITH | LW-750-300 | E9738081 | 1999 | X | CNRMA | ||||
| YORK-2062 | 21,600.00 | BOILER, GAS FIRED | COIL | HOT WATER | 500,000 BTU 196 HP | GAS | A.O. SMITH | LW-750-300 | M9742193 | 1999 | X | CNRMA | ||||
| YORK-2075 | 54,937.00 | BOILER, GAS FIRED | FIRE TUBE | HOT WATER | 750,300 BTU 295 HP | GAS | FULTON | PHW-750 | 95731 | 2005 | X | CNRMA | ||||
| YORK-2075 | 54,937.00 | BOILER, GAS FIRED | FIRE TUBE | HOT WATER | 750,300 BTU 295 HP | GAS | FULTON | PHW-750 | 95730 | 2005 | X | CNRMA | ||||
| YORK-2075 | 54,937.00 | BOILER, GAS FIRED | COIL | HOT WATER | 750,300 BTU 295 HP | GAS | A.O. SMITH | LW-750-300 | C0401970 | 2005 | X | CNRMA | ||||
| YORK-2075 | 54,937.00 | BOILER, GAS FIRED | COIL | HOT WATER | 750,300 BTU 295 HP | GAS | A.O. SMITH | LW-750-300 | B0371740 | 2005 | X | CNRMA | ||||
| YORK-2075 | 54,937.00 | CHILLER, CGAM, AIR COOLED | TRANE | CGAM100A2K02AXD2A1A | U13L39763 | 2013 | X | CNRMA | ||||||||
| YORK-2086 | 50,757.00 | BOILER, GAS FIRED | FIRE TUBE | HOT WATER | 855,000 BTU 336 HP | GAS | FULTON | PHW-950 | 957000 | 2006 | X | MIDLANT | ||||
| YORK-2086 | 50,757.00 | COOLING TOWER | EVAPCO | LSWE-4-519-Z | S-1333535 | 2006 | X | MIDLANT | ||||||||
| YORK-2094 | 13,206.00 | BOILER, GAS FIRED | FIRE TUBE | HOT WATER | 725, 000 BTU 285 HP | GAS | LOCHINVAR | FTX725N | L14H30143875 | 2015 | X | CNRMA | ||||
| YORK-2122 | 11,446.44 | COOLING TOWER | REYMSA | HFC-808115 | F48M3R1143C15432686 | 2016 | X | MARFORCOM | ||||||||
| YORK-2122 | 11,446.44 | BOILER, GAS FIRED | HOT WATER | 3,000,000 BTU | GAS | LOCHINVAR | 2016 | X | MARFORCOM | |||||||
| YORK-2122 | 11,446.44 | BOILER, GAS FIRED | HOT WATER | 3,000,000 BTU | GAS | LOCHINVAR | 2016 | X | MARFORCOM | |||||||
| YORK-2125 | 61,561.88 | COOLING, TOWER | RESYMA | HFC-808115 | F48M3R1143C15432683 | 2016 | X | MARFORCOM | ||||||||
| YORK-2125 | 61,561.88 | BOILER, GAS FIRED | HOT WATER | 3,000,000 BTU | GAS | LOCHINVAR | 2016 | X | MARFORCOM | |||||||
| YORK-2125 | 61,561.88 | BOILER, GAS FIRED | HOT WATER | 3,000,000 BTU | GAS | LOCHINVAR | 2016 | X | MARFORCOM |