Amendment_0004_Drawings_N4008518B6151.pdf
PDF 2 MB Posted
- Attached to
- Project 170019, Interior and Exterior Repairs, BEQ M440, MCB Camp Lejeune (Camp Johnson), North Carolina
- Solicitation number
- N4008518B6151
About this file
Amendment_0004_Drawings_N4008518B6151.pdf
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G m
CCCCCCCCCCCCC
ROOF HATCH
C C C
PC E7
E8
M3-31
EF-4
M3-33
29610
NO
RT
H CAROL INA
PR
OFESS I ONA L
SEAL
E
N G I N E E
R
R O
B E
R T S C O T T P E R
K I
N S
320-C Midland Parkway, Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF
THE CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING
OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME
CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
AS NOTED
C. COOPER
N. HEBEL
S. PERKINS
INTERIOR & EXTERIOR REPAIRS AT BEQ
M440
ATTIC ELECTRICAL NEW WORK PLAN
E-102
133 14528 JULY 2017
60020346
15153G
N40085-17-B-0019
05-17-0019
NEW WORK KEYNOTES:
NO. DESCRIPTION
E7 CONNECT NEW RECEPTACLE TO UNSWITCHED LEG OF ATTIC LIGHTING CIRCUIT.
E8 PROVIDE PHOTOCELL MOUNTED ON ROOF PEAK AND CONNECT TO EXTERIOR
LIGHTING CONTROL PANEL. SEE DETAIL ON E-501.
1. SEE SHEET E-001 FOR GENERAL NOTES AND LEGEND.
2. SEE SHEET E-501 FOR LIGHTING FIXTURE SCHEDULE.
GENERAL NOTES:
SCALE: 3/32" = 1'-0"1 ATTIC ELECTRICAL NEW WORK PLAN
PLAN NORTH
SCALE: 3/32"=1'-0"
816 16
GRAPHIC SCALE
,W
V
V
CH-1
MECHANICAL
BUILDING
A501
H1-(1,3,5)
EXISTING
PANEL 'BB'
E12
HEAT TRACE
BB-(28,30)
HHWP-1
BB-(11,13,15)
HHWP-1
BB-(17,19,21)
PANEL 'H1'
T1
STEP-DOWN TRANSFORMER
G
MECHANICAL
BUILDING
A501
EXISTING
PANEL 'BB'
E13
EXISTING
PANEL 'BB'
MECHANICAL
BUILDING
A501
29610
NO
RT
H CAROL INA
PR
OFESS I ONA L
SEAL
E
N G I N E E
R
R O
B E
R T S C O T T P E R
K I
N S
320-C Midland Parkway, Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF
THE CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING
OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME
CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
AS NOTED
C. COOPER
N. HEBEL
S. PERKINS
INTERIOR & EXTERIOR REPAIRS AT BEQ
M440
ENLARGED ELECTRICAL NEW WORK PLANS
E-103
134 14528 JULY 2017
60020347
15153G
N40085-17-B-0019
15-17-0019
SCALE: 1/4" = 1'-0"2
ENLARGED MECHANICAL BUILDING/CHILLER
YARD NEW WORK POWER PLAN
NEW WORK KEYNOTES:
NO. DESCRIPTION
E12 PROVIDE NEW RECEPTACLE AND CONNECT TO EXISTING 120V
RECEPTACLE CIRCUIT INSIDE MECHANICAL BUILDING.
E13 PROVIDE NEW LIGHT FIXTURE WITH INTEGRAL PHOTOCELL AND
CONNECT TO EXISTING EXTERIOR LIGHITNG CIRCUIT.
SCALE: 1/4" = 1'-0"3
ENLARGED MECHANICAL BUILDING/CHILLER
YARD NEW WORK LIGHTING PLAN
GENERAL NOTES:
1. SEE SHEET E-001 FOR GENERAL NOTES AND LEGEND.
2. SEE SHEET E-501 FOR LIGHTING FIXTURE SCHEDULE.
3. SEE E-001 FOR COMMUNICATIONS AND CATV NOTES.
PLAN NORTH
04 8268 02 4 8134
SCALE: 1/4"=1'-0"
GRAPHIC SCALE
SCALE: 1/4" = 1'-0"1
ENLARGED MECHANICAL BUILDING
DEMOLITION PLAN
O S
O S3
G G
G
Gm m
OS
OS
V
J
OS
O S
O S
O S
G
G G
G m m m
OS
OS
V
J
OS
O S
O S3
O S
3 G
G G G
G G m m
G m
OSOS
V
J
OS
E-402
Y
F2
F1
Y
Y
Y
Y Y
Y
PANEL 'K'
LOUNGE
CORRIDOR
COMM ROOM
LAUNDRY
CENTRAL STAIR
EF-2
UH-2
C
C
C
D
LGT
BB
B B
BB
B B
G
G
AHU-2C
K-1 K-23
K-(38,40,42)
HAND
DRYER K-3
A
A
A
X1
X1
UP
DOWN
K-1
K-1
K-1
K-26
K-24 K-23
K-23
K-(8,10)
K-(12,14)
K-(16,18)
K-(20,22)
K-2
K-4
K-6
K-23 K-7
K-23
K-9
K-23
K-7
K-7
K-5
X1
Y
F2
F1
Y
Y
Y
Y
Y
PANEL 'Q'
LOUNGE
CORRIDOR
STORAGE
LAUNDRY
CENTRAL STAIR
EF-3
UH-3
FPB3B-21
D
C
G
G
AHU-3C
Q-1 Q-13
Q-(38,40,42)
HAND
DRYER Q-3
B B
B B
BB
B B
A
X1
A
A
X1
C
C
C
C
Y
DOWN
Q-1
Q-1
Q-1
Q-7 Q-13
Q-13
Q-13
Q-13
Q-13
Q-13
Q-7
Q-7
Q-5
Q-(28,30)
Q-11
Q-9
Q-2
Q-4
Q-6
Q-(8,10)
Q-(12,14)
Q-(16,18)
Q-(20,22)
Q-26
Q-24
X1
E-402
F2
Y
Y Y
Y
Y
Y
PANEL 'C'
PANEL 'D'
CORRIDOR
DUTY
NEW LAUNDRY ROOM
LAUNDRY
CENTRAL STAIR
120119
EF-1
UH-1
FPB1B-01
C
C
G
G
AHU-1C
C-1
C-19
C-(38,40,42) C-26C-1
C-(8,10)
C-(12,14)
C-(16,18)
C-(20,22)
C-2
C-4
C-6 C-1C-24
C-19
C
B
B
FACP
XTMR
B B
B B
D
HAND
DRYER C-3
BB
B
B
A
A
A
C
C
X1
X1
UP
C-1
C-1
C-5
C-7
C-7
C-15
C-13C-11C-9
C-17
C-17
C-19
C-19
C-19
C-19
C-19
C-21
C-(28,30)
C-23 C-25
C-19
C-19
C-7
29610
NO
RT
H CAROL INA
PR
OFESS I ONA L
SEAL
E
N G I N E E
R
R O
B E
R T S C O T T P E R
K I
N S
320-C Midland Parkway, Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF
THE CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING
OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME
CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
AS NOTED
C. COOPER
N. HEBEL
S. PERKINS
INTERIOR & EXTERIOR REPAIRS AT BEQ
M440
ENLARGED ELECTRICAL NEW WORK PLANS
E-401
135 14528 JULY 2017
60020348
15153G
N40085-17-B-0019
05-17-0019
SCALE: 1/4" = 1'-0"
E-101
ENLARGED SECOND FLOOR ELECTRICAL NEW
WORK PLAN
SCALE: 1/4" = 1'-0"
E-101
ENLARGED THIRD FLOOR ELECTRICAL NEW
WORK PLAN
1. SEE SHEET E-501 FOR LIGHTING FIXTURE SCHEDULE.
2. ALL 'X1' AND 'Y' TYPE FIXTURES ARE TO BE FED FROM UNSWITCHED LEG OF NEAREST LIGHTING
CIRCUIT. MOUNT 'X1' TYPE FIXTURES LOCATED IN CORRIDOR TO WALL ABOVE DOOR.
3. PROVIDE ALL COMMUNICATIONS CABLING, EQUIPMENT, AND JACK SET ASSEMBLIES
ASSOCIATED WITH OFFICE AREAS AND AREAS SERVICED BY BASE TELEPHONE SYSTEM PER
CAMP LEJEUNE COMMUNICATIONS SPECIFICATION 27 10 00. ALL WORK SHALL BE DONE BY A
QUALIFIED COMMUNICATIONS SUBCONTRACTOR. CONTACT CONSTRUCTION MANAGER
REGARDING ANY COMMUNICATIONS QUESTIONS.
4. ALL AHU UNITS SHALL BE PROVIDED WITH DEDICATED CONTROLS CIRCUIT, CONDUITM AND
WIRING. SEE PANEL SCHEDULES ON SHEETS E-601 AND E-602 FOR CIRCUITING. COORDINATE
FINAL CONNECTION WITH MANUFACTURER'S REQUIREMENTS.
5. FACP TO HAVE TWO GREEN CAT 6 CABLES TO COMM ROOM.
6. DRYER CIRCUIT TO BE 2#10, #10N, #10G 3/4"C.
GENERAL NOTES:
SCALE: 1/4" = 1'-0"
E-101
ENLARGED FIRST FLOOR ELECTRICAL NEW
WORK PLAN
PLAN NORTH
04 8268 02 4 8134
SCALE: 1/4"=1'-0"
m
O S
G G m
C
D D
VFPB
SLEEPING ROOM
208V
42"42"
CKT-B
CKT-A
CKT-A
E9
NEW LAUNDRY ROOM
D-(29,31)D-(1,3)
D-(5,7)
D-(9,11)
D-(13,15)
D-(17,19)
D-(21,23)
D-(25,27)
D-(33,35)
D-(37,39)
D-(2,4)
D-(6,8)
D-(10,12)
D-(14,16)
D-(18,20)
D-22
D-24
D-26
D-28
D-30
D-32
D-34
D-36
D-38
D-40
TGB
C
C C
COMM ROOM
FCU-1
TELEPHONE
BACKBOARD
K-11
K-13
K-15
K-21
K-19
K-17
K-23
E10
29610
NO
RT
H CAROL INA
PR
OFESS I ONA L
SEAL
E
N G I N E E
R
R O
B E
R T S C O T T P E R
K I
N S
320-C Midland Parkway, Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF
THE CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING
OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME
CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
AS NOTED
C. COOPER
N. HEBEL
S. PERKINS
INTERIOR & EXTERIOR REPAIRS AT BEQ
M440
ENLARGED ELECTRICAL NEW WORK PLANS
E-402
136 14528 JULY 2017
60020349
15153G
N40085-17-B-0019
05-17-0019
SCALE: 1/4" = 1'-0"
E-101
TYPICAL ENLARGED SLEEPING
ROOM NEW WORK PLAN
GENERAL NOTES:
1. SEE SHEET E-501 FOR LIGHTING FIXTURE SCHEDULE.
2. ALL 'Y' AND 'X1' TYPE FIXTURES ARE TO BE FED FROM UNSWITCHED LEG OF NEAREST
LIGHTING CIRCUIT. MOUNT 'X1' TYPE FIXTURES LOCATED IN COORIDOR TO WALL ABOVE
DOOR.
3. PROVIDE ALL COMMUNICATIONS CABLING, EQUIPMENT, AND JACK SET ASSEMBLIES
ASSOCIATED WITH OFFICE AREAS ADN AREAS SERVICED BY BASE TELEPHONE SYSTEM
PER CAMP LEJEUNE COMMUNICATIONS SPECIFICATION 27 10 00. ALL WORK SHALL BE
DONE BY A QUALIFIED COMMUNICATIONS SUBCONTRACTOR. CONTACT CONSTRUCTION
MANAGER REGARDING ANY COMMUNICATIONS QUESTIONS.
4. HORIZONAL CATV COAX FROM BEQ ROOMS TO THE CHASE WAY ARE TO BE REMOVED
AND REPLACED WITH NEW.
5. ALL AHU UNITS SHALL BE PROVIDED WITH DEDICATED CONTROLS CIRCUIT, CONDUIT,
AND WIRING. SEE PANEL SCHEDULES ON SHEETS E-601 AND E-602 FOR CIRCUITING.
COORDINATE FINAL CONNECTION WITH MANUFACTURER'S REQUIREMENTS.
6. DRYER CIRCUIT TO BE 2#10, #10N, #10G 3/4"C.
SCALE: 1/4" = 1'-0"
E-401
ENLARGED LAUNDRY POWER
NEW WORK PLAN
SCALE: 1/2" = 1'-0"
E-401
ENLARGED COMMUNICATIONS
ROOM NEW WORK PLAN
04 8268 02 4 8134
SCALE: 1/4"=1'-0"
PLAN NORTH
1 2 42
SCALE: 1/2"=1'-0"
GRAPHIC SCALES
NOTES:
CKT 'A' - RECEPTACLES - ROOM/GFCI
CKT 'B' - LIGHTING
SEE PANEL SCHEDULES FOR SPECIFIC ROOM
CIRCUITS.
NEW WORK KEYNOTES:
NO. DESCRIPTION
E9 SEE PANEL SCHEDULE FOR SPECIFIC MECHANICAL EQUIPMENT CIRCUIT.
E10 PROVIDE 1" CONDUIT WITH PULLSTRING TO CU-1. COORDINATE WITH
MECHANICAL REFRIGERANT LINE ROUTING TO BE USED FOR CONDUIT.
G G
G m
V m
G
G m
G
V m
G
G m
G
V m
GG
m
G
V m
3 G G m
G
V m
V
V
3 G G m
G
V m
V
V
C
C
C
C
PANEL 'MDP'
PANEL 'A'
Y
PANEL 'B'
PANEL 'M1'
'B-AAC-AHU-1A'
PANEL
'B-BC-AC'
PANEL
AHU-1A
MECHANICAL
DHU-1A
M1-17
M1-(11,13,15)
Y
VAVOA-1A
M1-19
M1-7
M1-9
M1-3
M1-1
M1-1
M1-1
C
C
PANEL 'F'
Y
PANEL 'G'
MECHANICAL
DHU-1B
C
C
'B-AAC-AHU-1B'
PANEL
'B-BC-B' PANEL
AHU-1B
M1-18
M1-(12,14,16)
Y
VAVOA-1B
M1-19
M1-2
M1-2
M1-8
M1-10M1-2
M1-4
C
C
Y
PANEL 'H'
PANEL 'J'
PANEL 'M2'
MECHANICAL
DHU-2A
C
C
'B-AAC-AHU-2A'
PANEL
AHU-2A
Y
VAVOA-2A
M2-7
M1-(11,13,15)
M2-17
M2-9
M2-3
M2-1
M2-1M2-1
C
C
PANEL 'L'
YPANEL 'N'
MECHANICAL
DHU-2B
C
C
AHU-2B
Y
VAVOA-2B
'B-AAC-AHU-2B'
PANEL
M2-18
M2-(12,14,16)
M2-19
M2-2 M2-2
M2-10
M2-2
M2-4
C
C
PANEL 'O'
PANEL 'P'
PANEL 'M3'
ERV-A
MECHANICAL
DHU-3A
C
C
'B-AAC-AHU-3A'
PANEL
AHU-3A
M3-(11,13,15)
VAVOA-3A
M3-32
M3-7
Y
ERV-A
'B-AAC-ERV-A'
PANEL
Y
M3-3
M3-1
M3-9
M3-1
M3-(19,21,23)
M3-(26,28,30)M3-17
M3-1
MECHANICAL
C
C
PANEL 'R'
'B-AAC-ERV-B'
PANEL
ERV-B
C
C
'B-AAC-AHU-3A'
PANEL
AHU-3B
M3-(12,14,16)
VAVOA-3B
M3-32
M3-8
ERV-B
PANEL 'S'
DHU-3B
Y
M3-2
M3-2
M3-2
M3-10
M3-(20,22,24)
M3-(26,28,30)
M3-18
M3-4
29610
NO
RT
H CAROL INA
PR
OFESS I ONA L
SEAL
E
N G I N E E
R
R O
B E
R T S C O T T P E R
K I
N S
320-C Midland Parkway, Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF
THE CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING
OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME
CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
AS NOTED
C. COOPER
N. HEBEL
S. PERKINS
INTERIOR & EXTERIOR REPAIRS AT BEQ
M440
ENLARGED ELECTRICAL NEW WORK PLANS
E-403
137 14528 JULY 2017
60020350
15153G
N40085-17-B-0019
05-17-0019
SCALE: 1/4" = 1'-0"
E-101
ENLARGED ELECTRICAL
NEW WORK PLAN
SCALE: 1/4" = 1'-0"
E-101
ENLARGED ELECTRICAL
NEW WORK PLAN
GENERAL NOTES:
1. SEE SHEET E-501 FOR LIGHTING FIXTURE SCHEDULE.
2. SEE E-001 FOR COMMUNICATIONS AND CATV NOTES.
3. COORDINATE PANELBOARD AND LIGHTING LOCATIONS WITH ALL OTHER
DISCIPLINES PRIOR TO ROUGH IN.
4. ALL AHU AND ERV UNITS SHALL BE PROVIDED WITH DEDICATED CONTROLS
CIRCUIT, CONDUIT, AND WIRING. SEE PANEL SHCEDULES ON SHEETS E-601
AND E-602 FOR CIRCUITING. COORDINATE FINAL CONNECTION WITH
MANUFACTURER'S RREQUIREMENTS.
5. MECHANICAL EQUIPMENT DDC PANELS TO HAVE TWO GREEN CAT 6 CABLES
TO COMM ROOM.
SCALE: 1/4" = 1'-0"
E-101
ENLARGED ELECTRICAL
NEW WORK PLAN
SCALE: 1/4" = 1'-0"
E-101
ENLARGED ELECTRICAL
NEW WORK PLAN
SCALE: 1/4" = 1'-0"
E-101
ENLARGED ELECTRICAL
NEW WORK PLAN
SCALE: 1/4" = 1'-0"
E-101
ENLARGED ELECTRICAL
NEW WORK PLAN
PLAN NORTH
04 8268 02 4 8134
PRISMATIC LENS FLUORESCENT TROFFER
REVISED: APRIL 2016 NL-4LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-FORMED, COLD-ROLLED STEEL. EXTRUDED ALUMINUM DOOR WITH
SPRING-LOADED CAM LATCHES. OPTIONAL SIZES OF 1FT x 4FT, 2FT x 2FT, AND 2FT x 4FT AVAILABLE.
2. FINISH - MULTI-STAGE PHOSPHATE BONDING TREATMENT FINISHED WITH
HIGH-REFLECTANCE, BAKED WHITE ENAMEL OR POLYESTER POWDER COAT; PAINTED
AFTER FABRICATION.
3. LENS - 100% VIRGIN ACRYLIC, CLEAR PRISMATIC PATTERN A12 WITH MINIMUM 0.125
IN. THICKNESS.
4. LIGHT SOURCE - LINEAR T8, T5, OR COMPACT TT5 FLUORESCENT WITH QUANTITY AND
CHARACTERISTICS AS INDICATED IN LUMINAIRE SCHEDULE.
5. BALLAST - PROGRAMMED-START, CLASS P, THERMALLY-PROTECTED, HIGH POWER
FACTOR (>0.9), ELECTRONIC TYPE WITH <20% THD AND 'A' SOUND RATING. SEE
LUMINAIRE SCHEDULE FOR OPTIONS SUCH AS DIMMING CAPABILITY.
6. CERTIFICATIONS - UL 1598, DAMP LOCATION, UL 924 WHEN EQUIPPED WITH
EMERGENCY BATTERY BACK-UP.
7. MOUNTING - RECESSED IN SUSPENDED ACOUSTICAL TILE OR HARD CEILING.
8. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT
MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A
CERTAIN MANUFACTURER OR PREFERENCE.
SURFACE FLUORESCENT WRAPAROUND
REVISED: APRIL 2016 NL-6LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-FORMED, COLD-ROLLED STEEL, WITH REINFORCEMENT RIBS FOR
RIGIDITY; ENDCAPS SAME MATERIAL AS HOUSING, SECURED WITH TABS, SCREWS OR
RIVETS. OPTIONAL LENGTHS OF 2FT OR 4FT.
2. FINISH - MULTI-STAGE PHOSPHATE BONDING TREATMENT FINISHED WITH
HIGH-REFLECTANCE, WHITE POLYESTER POWDER COAT, PAINTED AFTER FABRICATION.
3. LENS - 100% VIRGIN ACRYLIC, CLEAR PRISMATIC DIFFUSER WITH MINIMUM 0.1 INCH
THICKNESS, CONTINUOUSLY SUPPORTED ALONG SIDES OF LUMINAIRE.
4. LIGHT SOURCE - LINEAR T8 OR T5, WITH QUANTITY AND WATTAGE AS INDICATED IN
LUMINAIRE SCHEDULE. 3500K CCT UON; MINIMUM CRI OF 80.
5. BALLAST - PROGRAMMED-START, CLASS P, THERMALLY-PROTECTED < 20% TOTAL
HARMONIC DISTRIBUTION, HIGH POWER FACTOR (> 0.9), ELECTRONIC TYPE WITH 'A' SOUND
RATING. DIMMING OPTION AVAILABLE
6. CERTIFICATION - UL 1598, DAMP LOCATION, AND ROHS COMPLIANT. UL 924 WHEN
EQUIPPED WITH EMERGENCY BATTERY BACK-UP
7. MOUNTING - SURFACE ON CEILING OR SUSPENDED.
8. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT
MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A
CERTAIN MANUFACTURER OR PREFERENCE.
WALL MOUNTED FLUORESCENT
REVISED: APRIL 2016 NL-10LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-FORMED, COLD-ROLLED STEEL, WITH REINFORCEMENT RIBS FOR
RIGIDITY; END CAPS SAME MATERIAL AS HOUSING, SECURED WITH TABS, SCREWS OR
RIVETS. WHITE ENAMEL FINISH APPLIED AFTER FABRICATION. OPTIONAL LENGTHS OF 2
FT, 3 FT OR 4 FT.
2. LENS - ACRYLIC PRISMATIC (CLEAR PRISMATIC PATTERN A12) OR WHITE OPAL, WITH
MINIMUM THICKNESS OF 0.125 IN.
3. LIGHT SOURCE - LINEAR T8, T5 OR T5HO FLUORESCENT TUBES WITH QUANTITY AND
CHARACTERISTICS AS INDICATED IN LUMINAIRE SCHEDULE.
4. BALLAST - PROGRAMMED-START, CLASS P, THERMALLY-PROTECTED, HIGH POWER
FACTOR (>0.9), ELECTRONIC TYPE WITH <20% THD AND 'A' SOUND RATING.
5. CERTIFICATION - UL 1598, DAMP LOCATION, UL 924 WHEN EQUIPPED WITH
EMERGENCY BATTERY BACK-UP.
6. MOUNTING - SURFACE ON WALL.
7. OPTIONS - EMERGENCY BACK-UP, <10% THD BALLAST, DOWNLIGHT COMPONENT ONLY.
8. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE
THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE
A CERTAIN MANUFACTURER OR PREFERENCE.
FLUORESCENT ENCLOSED AND GASKETED
REVISED: APRIL 2016 NL-12LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - FIBERGLASS OR FIBERGLASS-REINFORCED POLYESTER OUTER HOUSING,
WITH ALUMINUM COMPONENT TRAY. OPTIONAL LENGTHS OF 4 FT OR 8 FT.
2. LENS - IMPACT-RESISTANT ACRYLIC OR OPTIONAL POLYCARBONATE, WITH CONTINUOUS
CLOSED-CELL POLYURETHANE GASKET, SECURED WITH STAINLESS STEEL OR OPTIONAL
POLYCARBONATE LATCHES.
3. LIGHT SOURCE - LINEAR T8, T5 OR T5HO FLUORESCENT TUBES WITH QUANTITY AND
CHARACTERISTICS AS INDICATED IN LUMINAIRE SCHEDULE.
4. BALLAST - PROGRAMMED-START, CLASS P, THERMALLY-PROTECTED, HIGH POWER
FACTOR (>0.9), ELECTRONIC TYPE WITH <20% THD AND 'A' SOUND RATING.
5. CERTIFICATION - UL 1598, WET LOCATION (IP65, IP66, IP67), UL 924 WHEN
EQUIPPED WITH EMERGENCY BATTERY BACK-UP.
6. MOUNTING - SURFACE-MOUNTED OR SUSPENDED FROM CEILING.
7. OPTIONS - EMERGENCY BACK-UP, INTEGRAL MOTION SENSOR, DIMMING.
8. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT
MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A
CERTAIN MANUFACTURER OR PREFERENCE.
HOUSING - DIE-CAST ALUMINUM. SINGLE OR DOUBLE FACED AS INDICATED
LETTERS/CHEVRONS - MINIMUM 6" HIGH WITH 3/4" STROKE. RED OR GREEN LETTERS
FINISH (ON CAST ALUMINUM HOUSING ONLY) - TEXTURED POWDER COAT FINISH
OPTIONS INCLUDE WHITE, WHITE WITH BRUSHED ALUMINUM FACE, BLACK, OR BLACK
EMERGENCY PACK - SOLID-STATE, CONSTANT-CURRENT TYPE BATTERY CHARGER WITH
MOUNTING - UNIVERSAL MOUNTING KIT FOR CEILING, WALL OR END-OF-FIXTURE
ILLUMINATION - PROVIDED BY RED, GREEN OR WHITE HIGH-OUTPUT LEDS INSIDE
1.
2.
3.
4.
5.
6.
LUMINAIRE REQUIREMENTS:
REVISED: AUGUST 2004 NL-63
MOUNTING.
AS INDICATED. PROVIDE CHEVRONS AS INDICATED EITHER LEFT, RIGHT OR BOTH
MAINTENANCE-FREE, NICKEL-CADMIUM BATTERY, AC-ON INDICATOR LAMP AND
LIGHTING PLATE:
LED EXIT SIGN
13"
NOMINAL
NOMINAL
9"
WITH BRUSHED ALUMINUM FACE.
DIRECTIONS AS INDICATED. CHEVRONS PUNCHED OUT THROUGH HOUSING AS REQUIRED.
TEST SWITCH.
OF FIXTURE HOUSING. PROVIDE POLYSTYRENE DIFFUSER IN COLOR INDICATED WITH
FREQUENCY-MATCHED SILKSCREEN COATING FOR MAXIMUM LED LIGHT OUTPUT.
CERTIFICATION - UL LISTED AND CERTIFIED FOR DAMP LOCATIONS.7.
PRISMATIC LENS RECESSED 4' FLUORESCENT TROFFER
HOUSING - DIE-FORMED, COLD-ROLLED STEEL, WITH REINFORCEMENT RIBS FOR
LENS - 100% ACRYLIC, CLEAR PRISMATIC, PATTERN #12 WITH MINIMUM
FINISH - MULTI-STAGE PHOSPHATE BONDING TREATMENT FINISHED WITH HIGH
REFLECTANCE (MINIMUM 85%), BAKED WHITE ENAMEL FINISH.
LAMPS - LINEAR FLUORESCENT T8, TYPICALLY WITH WATTAGES AS INDICATED. SEE
BALLAST - CLASS P, THERMALLY-PROTECTED, HIGH POWER FACTOR ( .95),
CERTIFICATION - UL LISTED AND LABELED.
PHOTOMETRICS - MINIMUM VALUE OF COEFFICIENT OF UTILIZATION (CU) AND
EFFICIENCY, GIVEN INTERIOR CAVITY REFLECTANCES OF 80-50-20:
1.
2.
3.
4.
5.
6.
7.
LUMINAIRE REQUIREMENTS:
REVISED: AUGUST 2004 NL-2
ELECTRONIC TYPE WITH SOUND RATING A. SEE SPECIFICATION OR LIGHTING FIXTURE
RIGIDITY. ENDCAPS SECURED WITH TABS, SCREWS OR RIVETS. FIXTURE SHALL NOT
0.125" THICKNESS.
LIGHTING FIXTURE SCHEDULE.
LIGHTING PLATE:
4" NOMINAL
SCHEDULE FOR BALLAST OPTIONS AND SPECIFICS.
EFFICIENCY - 65%
4 51
2 LAMP (F32/T8)
RCR
CU
PERMANENTLY DEFORM OUT OF "SQUARE" WHEN PICKED UP FROM ANY CORNER. DEPTH
AS INDICATED UNLESS SPECIFICALLY MANUFACTURED FOR OPTIMAL USE WITH T8 LAMPS.
REVISED: AUGUST 2004 NL-48LIGHTING PLATE:
WALL-MOUNTED HIGH ABUSE FIXTURE
FLUORESCENT LAMPS.
COAT FINISH IN BLACK.
PROVIDE WITH WATTAGES AS INDICATED. SEE LIGHTING FIXTURE SCHEDULE.
ELECTRONIC TYPE WITH 10% TOTAL HARMONIC DISTORTION FOR COMPACT
CERTIFICATION - UL LISTED AND LABELED FOR WET LOCATIONS.
LAMPS - MULTI-TUBE COMPACT FLUORESCENT WITH 4-PIN BASE OR INCANDESCENT.
WITH MINIMUM 1/8" THICKNESS. DIFFUSER SECURED WITH TAMPER-RESISTANT
DIFFUSER - CLEAR PRISMATIC, UV-STABILIZED, INJECTION-MOLDED POLYCARBONATE
BALLAST - CLASS P, HIGH POWER FACTOR ( .95), PROGRAMMED RAPID START
HOUSING - ONE-PIECE, DIE-CAST ALUMINUM WITH BAKED-ON POLYESTER POWDER
6.
LUMINAIRE REQUIREMENTS:
5.
4.
2.
1.
STAINLESS STEEL SCREWS. BLACK HORIZONTAL FRONT EYELID FOR CUTOFF.
GASKET - ONE-PIECE, CLOSED-CELL NEOPRENE TO DISCOURAGE MOISTURE,3.
INSECTS AND DEBRIS.
6"
NOMINAL
NOMINAL
9"
NOMINAL
7"
FUSE
LIGHTING CONTROLLER
CABINET (NEMA 3R)
ON AT DUSK (10 F.C.)
OFF AT MIDNIGHT (ADJUSTABLE)
ON AT 5:00 A.M. (ADJUSTABLE)
OFF AT DAWN (10 F.C.)
SELECTOR
SWITCH
PHOTOCELL ON
ROOF, SPDT TYPE
SEVEN DAY
ELECTRONIC TIMER
WITH THREE DAY
BATTERY BACKUP
CLOSE
AUTO
OFF
ON
PERM,
MAGNETIC
LATCH TYPE
CONTACTOR
OPEN
120V
C
M
NEUTRAL
FIXTURE
CIRCUITS
C-31
K-25
Q-15
SPARE
29610
NO
RT
H CAROL INA
PR
OFESS I ONA L
SEAL
E
N G I N E E
R
R O
B E
R T S C O T T P E R
K I
N S
320-C Midland Parkway, Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF
THE CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING
OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME
CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
NONE
C. COOPER
N. HEBEL
S. PERKINS
INTERIOR & EXTERIOR REPAIRS AT BEQ
M440
ELECTRICAL LIGHTING DETAILS
E-501
138 14528 JULY 2017
60020351
15153G
N40085-17-B-0019
05-17-0019
LIGHTING FIXTURE SCHEDULE
C
B
STYLE NO. & TYPE VOLTAGE MOUNTING NOTESFIXTURE
SYMBOL
NUMBER AND TYPE
OF LAMPS
NL-4 2-17W/T8 120 RECESSED CEILING
SURFACE MTD.1202-32W/T8NL-6
NL-63X1 120 WALL MTD.
8'-0" A.F.F.LED
NL-12F1 120 WALL MTD.
6'-6" A.F.F.2-32W/T8
NL-10D 120 WALL MTD.
7'-0" A.F.F.2-32W/T8
NL-67Y 120 WALL MTD.
8'-0" A.F.F.LED
A NL-2 2-32W/T8 120 RECESSED CEILING
NL-48G 1201-18W/CFL WALL MTD.
7'-6" A.F.F.
NL-12F2 120 SURFACE MTD.2-32W/T8
NL-63X2 120 WALL MTD.
8'-0" A.F.F.LED 1, 2
NOTES:
1. EQUIPPED WITH TWO EMERGENCY HEADS.
2. FIXTURE TO BE VANDALPROOF.
REVISED: AUGUST 2004 NL-67LIGHTING PLATE:
DECORATIVE EMERGENCY LIGHTING UNIT
MR16 HALOGEN LAMPS SHALL BE 5 WATTS, HIGH-OUTPUT OR AS INDICATED IN
HOUSING - UV STABLE, FLAME-RATED, HIGH-IMPACT THERMOPLASTIC IN WHITE OR
BLACK TEXTURED FINISH.
INTERNAL COMPONENTS - FULLY AUTOMATIC, SOLID STATE, CONSTANT VOLTAGE,
CURRENT-LIMITED BATTERY CHARGER; MAINTENANCE-FREE LEAD-ACID BATTERY;
EXTERIOR HOUSING INDICATORS - LED AC-ON INDICATOR AND INTEGRAL TEST SWITCH.
LAMP HEADS - UV STABLE, FLAME RATED POLYCARBONATE THERMOPLASTIC.
MOUNTING - DIRECTLY TO 4" OCTAGONAL OR SQUARE OUTLET BOX.
CERTIFICATION - UL LISTED AND LABELED. COMPLIES WITH UL 924 AND NFPA 101
OPTIONS - VOLTMETER, VANDEL-RESISTANT SHIELD, SELF-DIAGNOSTIC/TESTING7.
6.
REQUIREMENTS. LISTED FOR DAMP LOCATIONS.
LUMINAIRE REQUIREMENTS:
1.
3.
5.
4.
2.
AND BUILT-IN OVERLOAD AND LOW-VOLTAGE BATTERY PROTECTION.
13"
NOMINAL
NOMINAL
5"
MAX. DEPTH
4" NOMINAL
ELECTRONICS AND WIRE GUARD.
LIGHTING FIXTURE SCHEDULE.
SCALE: NOT TO SCALE1 EXTERIOR LIGHTING SCHEMATIC
NOTES:
1. ALL OF THE TELEPHONE/DATA WIRING IS TO BE IN AN APPROVED
PATHWAY FROM THE OUTLET BACK TO THE BACKBOARD PER
SPECIFICATIONS AND STANDARDS. OPEN FACE TELECOMM SUPPORTS
SUCH AS BRIDAL RINGS AND J-HOOKS ARE NOT AUTHORIZED.
2. PROVIDE ALL COMMUNICATIONS CABLING, EQUIPMENT, AND JACK SET
ASSEMBLIES ASSOCIATED WITH OFFICE AREAS (WHERE APPLICABLE)
AND AREAS SERVICED BY BASE TELEPHONE SYSTEM PER CAMP
LEJEUNE COMMUNICATIONS SPECIFICATION 27 10 00. ALL WORK SHALL
BE DONE BY A QUALIFIED COMMUNICATIONS SUBCONTRACTOR.
CONTACT CONSTRUCTION MANAGER REGARDING ANY
COMMUNICATIONS QUESTIONS.
1 1/4" CONDUIT WITH FOUR (4
PAIR
UTP, 24 AWG, CAT 6 CABLES)
NOTE 1
SINGLE GANG
PLASTER RING
5" SQUARE BOX SURFACE
MOUNTED ON WALL
TELEPHONE
EQUIPMENT
RACKS
TELEPHONE/DATA
DROPS (TYP)
TWO 4'Hx8'Wx3/4"D
PLYWOOD BACKBOARDS
TELEPHONE
BACKBOARD
FIRST FLOOR
SECOND FLOOR
COMM ROOM
KEYNOTES:
NOTES:
GROUND FOR BACKBOARD TO BE MADE WITH GREEN
SHEATH #6 STRANDED COPPER IN 3/4"C TO COPPER BUS
BAR.
FROM TELECOMMUNICATIONS MANHOLE, AS SHOWN ON ES101,
PROVIDE SERVICE ENTRANCE IN (1) - 4 INCH PVC BELOW GRADE/SLAB
WITH TRANSITION TO (1) - 4 INCH EMT ABOVE GRADE/SLAB TO ROOM
224 AS DESIGNATED BY TSD. SEE ES101 FOR CONTINUATION.
PROVIDE 1/4"x4"x10" COPPER BUS BAR WITH INSULATING BRACKETS
AT TELEPHONE BACKBOARD IN ACCORDANCE WITH ANSI/TIA-607.
CONDUITS SHOULD EITHER COME UP FROM THE FLOOR OR DOWN
FROM THE CEILING AND TERMINATE 3" ON THE BACKBOARD AND
ALL BEBONDED TOGETHER AND GROUNDED WITH A GROUNDING
LUG ON THE END.
1. COORDINATE BACKBOARD LOCATION WITH BASE TELEPHONE.
2. PROVIDE ALL COMMUNICATIONS CABLING, EQUIPMENT, AND JACK SET ASSEMBLIES ASSOCIATED WITH OFFICE AREAS AND AREAS SERVICED BY BASE TELEPHONE SYSTEM PER CAMP LEJEUNE COMMUNICATIONS SPECIFICATION 27 10 00. ALL WORK SHALL BE DONE BY A QUALIFIED COMMUNICATIONS SUBCONTRACTOR. CONTACT CONSTRUCTION MANAGER REGARDING ANY COMMUNICATIONS QUESTIONS.
3. PROVIDE 1 1/4" CONDUIT WITH TWO CAT 6 CABLES FROM TELECOMMUNICATIONS RACK TO FACP. PROVIDE DUAL DATA/COMMUNICATIONS
JACK IN FACP. COORDINATE WITH LOCATION OF RACK AND FINAL LOCATION OF FACP.
4. TELEPHONE BACKBOARDS - PROVIDE VOID-FREE, INTERIOR GRADE PLYWOOD 3/4" THICK. BACKBOARDS SHALL BE FIRE RETARDANT TREATED PLYWOOD, WITH THE FIRE STAMP VISIBLE. BOARDS SHOULD BE INSTALLED 4' WIDTH BY 8' HEIGHT SECURELY FASTENED TO THE
WALL ANYWHERE EQUIPMENT IS TO BE MOUNTED.
5. ALL METALLIC CONDUIT AND EQUIPMENT MUST BE BONDED TO THE TMGB AND BUILDING GROUND PER ANSI/TIA-607 WITH MINIMUM #6
STRANDED GREEN SHEATH CONDUCTOR.
6. ALL CONDUITS NEED TO BE SECURELY MOUNTED, FIRE STOPPED, AND OVER LAP THE BACKBOARD BY 3-6".
7. INSTALL CABLES IN AN APPROVED PATHWAY PER THE SPECIFICATIONS AND STANDARDS; INSTALL ALL LADDER RACKS WITHIN TELECOMM ROOM, PATCH PANELS, CABINETS, BUILDING PROTECTORS, OSP CABLE, RISER CABLE, AND EQUIPMENT IAW BASE TELE 27 10 00. OPEN FACE TELECOMMUNICATIONS SUPPORTS ARE NOT ACCEPTABLE, E.G. BRIDAL RINGS AND J-HOOKS ARE NOT ACCEPTABLE.
NOTES:
1" CONDUIT WITH ONE RG-6
CABLE AND TWO (4 PAIR UTP, 24
AWG, CAT 6 CABLES)
SINGLE GANG
PLASTER RING
5" SQUARE BOX SURFACE
MOUNTED ON WALL
CATV
TELEPHONE
NOTE 1
1. ALL OF THE TELEPHONE/DATA WIRING IS TO BE IN AN APPROVED
PATHWAY FROM THE OUTLET BACK TO THE BACKBOARD PER
SPECIFICATIONS AND STANDARDS. CATV TO BE RG-6 AND TERMINATE
AT PATCH PANEL. OPEN FACE TELECOMM SUPPORTS SUCH AS
2. PROVIDE ALL COMMUNICATIONS CABLING, EQUIPMENT, AND JACK SET
ASSEMBLIES ASSOCIATED WITH OFFICE AREAS (WHERE APPLICABLE)
AND AREAS SERVICED BY BASE TELEPHONE SYSTEM PER CAMP
LEJEUNE COMMUNICATIONS SPECIFICATION 27 10 00. ALL WORK SHALL
BE DONE BY A QUALIFIED COMMUNICATIONS SUBCONTRACTOR.
CONTACT CONSTRUCTION MANAGER REGARDING ANY
COMMUNICATIONS QUESTIONS.
3. IN EACH SLEEPING ROOM, PROVIDE TWO TELEPHONE AND ONE CATV
JACK IN EACH FACEPLATE. PROVIDE TWO FACEPLATE CONFIGURATIONS
PER SLEEPING ROOM FOR A COMBINED TOTAL FOUR TELEPHONE
DROPS AND TWO CATV DROPS.
BRIDAL RINGS AND J-HOOKS ARE NOT AUTHORIZED.
CONC. SLAB
DUCTS ENTERING BUILDING
FOOTING
GROUND LEVEL
EXTERNAL WALL
24" MIN.
BELOW
GRADE
4" MIN.
FROM WALL
40" MINIMUM RADIUS
FOR CONDUITS 3"
AND LARGER AND
18" FOR CONDUITS
SMALLER THAN 3"
STUB UP 4" ABOVE
CONCRETE SLAB AND
2" BETWEEN DUCTS
STEEL PVC
4" MIN.
4"
CONCRETE ENCASEMENT
FLOOR
W
AL
L
PLASTIC
COATED RIGID
STEEL CONDUIT
PVC TO STEEL
ADAPTER
2"
2' - 0" MIN.
1 1/2" TYP.
4"
2"
1"
1"
1"
5/ 8"
3/8" DIA. HOLE TYP.
1/4" DIA. HOLE TYP.
1/2" NUT
1/4" DIA.
MOUNTING HOLE
TYP. OF 4
GENERAL NOTES:
1. ALL HARDWARE SHOWN SHALL BE STAINLESS STEEL.
2. PROVIDE 1 MOUNTING POINT PER 24" OF BAR LENGTH.
3. HOLES MAY BE ADDED IF REQUIRED.
1"
A
A
PLAN
SECTION A-A
2"
5"
1/2" DIA.x2"L BOLT TYP OF 2
1/2" NUT
STEEL EXPANSION
ANCHOR FOR CMU
WALLS, SCREW TO
STUDS FOR GYP.
WALLS
1/2" LOCK WASHER
1/2" STANDARD WASHER
1/2" FENDER WASHERS (EACH
SIDE)
3" DEEP FIBERGLASS CHANNEL
SAME LENGTH AS CU BUSS
29610
NO
RT
H CAROL INA
PR
OFESS I ONA L
SEAL
E
N G I N E E
R
R O
B E
R T S C O T T P E R
K I
N S
320-C Midland Parkway, Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF
THE CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING
OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME
CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
AS NOTED
C. COOPER
N. HEBEL
S. PERKINS
INTERIOR & EXTERIOR REPAIRS AT BEQ
M440
ELECTRICAL DETAILS
E-502
139 14528 JULY 2017
60020352
15153G
N40085-17-B-0019
05-17-0019
SCALE: NOT TO SCALE1 OFFICE TELEPHONE/DATA OUTLET DETAIL (TYPICAL)
SCALE: NOT TO SCALE2 VOICE/DATA SYSTEM RISER
SCALE: NOT TO SCALE3 SLEEPING ROOM TELEPHONE/CATV OUTLET DETAIL (TYPICAL)
SCALE: NOT TO SCALE4 DUCT ENTRY INTO BUILDING
SCALE: NOT TO SCALE5 ENCASED UNDERSLAB STUB-UPS
SCALE: NOT TO SCALE6 GROUNDING BAR DETAIL
1 1 3' ALL SIDES
#4/0 AWG BARE COPPER IN 3/4" PVC TO GROUNDING LUG.
WELDED
CONNECTION
(TYP.)
3/4" x 10' MIN.
LENGTH GROUND
ROD (TYP.)
GROUND RING: #4/0 AWG BARE
COPPER DIRECT-BURIED 1'
BELOW GRADE
PRECAST BOX PAD
PAVED
CONDITION
4"
4"
WARNING TAPE
AND TRACER
WIRE 12" BELOW
GRADE
APPROVED
COMPACTED
BACKFILL IN
6" MAX. LIFTS
GRASS
CONDITION
UNDISTURBED
EDGE OF TRENCH
CONCRETE ENCASED
DUCTBANK, NUMBER
AND SIZE INDICATED
ON PLANS
GRANULAR BEDDING
NOTE: SEE SPECIFICATIONS
FOR BURIAL DEPTHS.
GRADE
" M
IN
3000 PSI CONCRETE
3"
NOTE:
1. AT EACH CORNER, PROVIDE #4
REINFORCING ROD INSTALLED AT 1 1/2"
FROM DUCT BANK SURFACE FOR ALL
DUCT BANKS UNDER ROADWAYS OR
PARKING AREAS.
3" 3"
3000 PSI CONCRETE
3"
NOTE:
1. AT EACH CORNER AND MIDDLE, PROVIDE
#4 REINFORCING ROD INSTALLED AT 1
1/2" FROM DUCT BANK SURFACE FOR ALL
DUCT BANKS UNDER ROADWAYS OR
PARKING AREAS.
3" 3"
NOTES:
1. ASSEMBLY TO BE PLACED ON A 6" BASE OF CRUSHER
RUN FOR EASE OF INSTALLATION AND EVEN LOAD
DISTRIBUTION.
2. ILLUSTRATION IS TYPICAL ONLY OF GENERAL SERIES
CONFIGURATION: FOR SPECIFIC CONFIGURATION
COORDINATE WITH MANUFACTURER.
3. ALL CONDUITS TO EXTEND 1" ABOVE TOP OF PAD.
4. COORDINATE PAD AND COMPARTMENT OPENING
DIMENSION REQUIREMENTS WITH TRANSFORMER
MANUFACTURER.
3'-0" ∅ 4'-0" x 5'-0"
MANHOLE VAULT
OPENING OPENING
A
B
C
D
TRANSFORMER PAD
LOWER SECTION
MINIMUM EXCAVATION SIZE:
4'-8" x 7'-8" x DEPTH REQUIRED.
E
F
30" X 48" ACCESS COVER
UNISTRUT
PULLING INSERTS
16" X 16" CORNER KNOCKOUTS - VARIOUS SIZES AVALIABLE
3'-6"
7'-0"
6"
3'-8"
D
B
6'-8"
3'-0"
6'-0" 3'-6"
E
C
4'-0"
F A
TRANSFOMER CABLE ACCESS OPENINGS AVALIABLE
IN DIFFERENT SIZES.
G
G
FIBERGLASS SLEEVE (EXPOSE
6" ABOVE GRADE)
3 PHASE, 4 POINT STEEL
15KV, 200A JUNCTION BOX
GROUND LUGS (TYP)
CONNECT GROUNDS TO
GROUND LOOP USING
SQUEEZE-ON
CONNECTIONS (TYP)
3/4IN X 10FT
GND ROD (TYP)
SERVICE LOOP CONDUCTORS
FROM EXISTING MANHOLE
SET SLEEVE ON 8" CRUSHED
STONE OR GRAVEL
CAD WELD GND ROD CONNECTIONS
#4/0 BARE CU GROUND LOOP
PARKING STAND (TYP)
15KV LOAD BREAK ELBOW
WITH TEST POINT (TYP)
PVC ELBOW, SIZE TO MATCH
EXISTING CONDUIT (TYP)
SPARE WELL (TYP OF 3 PER PHASE)
EXISTING SERVICE
LOOP CONDUCTORS
CONDUIT AND CONDUCTORS TO M440 PAD MOUNTED
TRANSFORMER, SEE RISER DIAGRAM FOR CONTINUATION
SPARE CONDUIT 5"
NOTE: PROVIDE NEW SECTIONALIZER CABINET WITH
LOOP FEED ADAPTER FOR ONE WELL.
GRADE
TO PANEL 'C' TO SSHP-1
ALUMINUM SQUARE TUBE
4"x4"x1/2" TOP CAP SET SQUARE
TUBE (COATED IN BITUMASTIC
IN CONCRETE PAD
ALUMINUM FLAT BAR 3"x1/2" ALL BOLTS, NUTS WASHERS, AND MISC. HARDWARE
SHALL BE STAINLESS STEEL. BONDING
JUMPERS SHALL BE PROVIDED ACROSS
ALL BOLTED JOINTS. FRAM MAY BE
WELDED. FRAME SHALL BE GROUNDED.
ON
OFF
30A ELECTRICAL DISCONNECT,
NEMA 3R
29610
NO
RT
H CAROL INA
PR
OFESS I ONA L
SEAL
E
N G I N E E
R
R O
B E
R T S C O T T P E R
K I
N S
320-C Midland Parkway, Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF
THE CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING
OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME
CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
AS NOTED
C. COOPER
N. HEBEL
S. PERKINS
INTERIOR & EXTERIOR REPAIRS AT BEQ
M440
ELECTRICAL DETAILS
E-503
140 14528 JULY 2017
60020353
15153G
N40085-17-B-0019
05-17-0019
SCALE: NOT TO SCALE2 SERVICE TRANSFORMER GROUNDING DETAIL
SCALE: NOT TO SCALE3 CONCRETE ENCASED DUCTBANK TRENCH DETAIL
SCALE: NOT TO SCALE4 2-WAY CONCRETE ENCASED DUCTBANK DETAIL
SCALE: NOT TO SCALE5 4-WAY CONCRETE ENCASED DUCTBANK DETAIL
SCALE: NOT TO SCALE1 SERVICE TRANSFORMER PAD WITH VAULT DETAIL
SCALE: NOT TO SCALE6 SECTIONALIZER CABINET DETAIL
SCALE: NOT TO SCALE7 EQUIPMENT PEDESTAL DETAIL
120/208V 3 4 1600A
SIZENO.NO.
INTERRUPTING AMPERE CURRENT
RATING FOR THIS ASSEMBLY
SHALL BE A. RMS SYM.
TOTAL DEMAND
TOTAL CONNECTED
65,000 508,959
468,461 1301VA AMPS
B A
CKT.
SIZE
BRKR CKT.LOAD VA LOADBRKR VA
1600A
PANEL NO. MDP
VA
VOLTAGE PHASE WIRE BUS SIZE MCB
31 32 33 34 35 36 37 38 39 40 41 42
C
B A
C
B A
C
B A
C
B A
C
B A
C
B A
C
PANEL A225
PANEL C225
PANEL D400
PANEL Q225
PANEL R225
PANEL M1125
PANEL M2125
PANEL M3225
PANEL O225
PANEL H225
PANEL K225
PANEL L225
PANEL F225
SPD60
39500
42699
83000
33111
35500
26024
25304
46760
35500
35500
35061
35500
35500
PROVIDE MDP WITH FOUR EXTRA 3 POLE SPACES.
120/208V 3 4 225A
SIZENO.NO.
INTERRUPTING AMPERE CURRENT
RATING FOR THIS ASSEMBLY
SHALL BE A. RMS SYM.
TOTAL DEMAND
TOTAL CONNECTED
22,000 39,500
37,250 103VA AMPS
B A
CKT.
SIZE
BRKR CKT.LOAD VA LOADBRKR VA
MLO
PANEL NO. A
VA
VOLTAGE PHASE WIRE BUS SIZE MCB
31 32 33 34 35 36 37 38 39 40 41 42
C
B A
C
B A
C
B A
C
B A
C
B A
C
B A
C
RCPT-101 (A)20 20
A - CIRCUIT BREAKER TO BE ARC-FAULT CIRCUIT-INTERRUPTER TYPE
(X) - DENOTES TYPICAL SLEEPING ROOM CIRCUIT. SEE ENLARGED ROOM NEW WORK PLAN.
LGT-101, 101B (B)
PANEL 'B'
A A A A A A A A
A A A A A A
RCPT-102 (A)
LGT-102, 102B (B)
20324
RCPT-103 (A)
LGT-103, 103B (B)
RCPT-105 (A)
LGT-105, 105B (B)
RCPT-107 (A)
LGT-107, 107B (B)
RCPT-104 (A)
LGT-104, 104B (B)
RCPT-106 (A)
LGT-106, 106B (B)
RCPT-108 (A)
LGT-108, 108B (B)
A A
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
30 SITE LIGHTING 4000
120/208V 3 4 125A
SIZENO.NO.
INTERRUPTING AMPERE CURRENT
RATING FOR THIS ASSEMBLY
SHALL BE A. RMS SYM.
TOTAL DEMAND
TOTAL CONNECTED
10,000 20,324
18,074 50VA AMPS
B A
CKT.
SIZE
BRKR CKT.LOAD VA LOADBRKR VA
MLO
PANEL NO. B
VA
VOLTAGE PHASE WIRE BUS SIZE MCB
C
B A
C
B A
C
B A
C
20 20
A A A A
20 FPB-101-108
20 FPB-111-118
A A A A
A - CIRCUIT BREAKER TO BE ARC-FAULT CIRCUIT-INTERRUPTER TYPE
(X) - DENOTES TYPICAL SLEEPING ROOM CIRCUIT. SEE ENLARGED ROOM NEW WORK PLAN.
B A
C
RCPT-111 (A)
LGT-111, 111B (B)
RCPT-113 (A)
LGT-113, 113B (B)
RCPT-115 (A)
LGT-115, 115B (B)
RCPT-117 (A)
LGT-117, 117B (B)
A A A A A A
RCPT-112 (A)
LGT-112, 112B (B)
RCPT-114 (A)
LGT-114, 114B (B)
RCPT-116 (A)
LGT-116, 116B (B)
RCPT-118 (A)
LGT-118, 118B (B)
A A
SPARE
SPARE
SPARE
SPARE
120/208V 3 4 225A
SIZENO.NO.
INTERRUPTING AMPERE CURRENT
RATING FOR THIS ASSEMBLY
SHALL BE A. RMS SYM.
TOTAL DEMAND
TOTAL CONNECTED
22,000 42,699
40,449 112VA AMPS
B A
CKT.
SIZE
BRKR CKT.LOAD VA LOADBRKR VA
MLO
PANEL NO. C
VA
VOLTAGE PHASE WIRE BUS SIZE MCB
31 32 33 34 35 36 37 38 39 40 41 42
C
B A
C
B A
C
B A
C
B A
C
B A
C
B A
C
RCPT-119,121-12320 20
LGT-119,121-126
AHU-1C 119
FACP
XMTR
RCPT-WASHER 121
RCPT-WASHER 121
DRYER 121
HAND DRYER 122
RCPT-126
RCPT-125,126
RCPT-VENDING
RCPT-VENDING
RCPT-VENDING
RCPT-EWC
RCPT-124
RCPT-WASHER 121
30 DRYER 121
30 DRYER 121
L - CIRCUIT BREAKER TO BE LOCK-ON TYPE
R - CIRCUIT BREAKER HANDLE TO BE RED IN COLOR
NOTE:
1. IN ADDITION TO THE PANEL NAMEPLATE. PROVIDE A LABEL WITH THE FOLLOWING
INSCRIPTION: 'FIRE PROTECTION/LIFE SAFETY EQUIPMENT'. CONSTRUCT AND FASTEN
LABEL INDENTICAL TO THE PANEL NAMEPLATE. EXCEPT THE LABEL MUST BE RED
LAMINATE PLASTIC WITH WHITE CENTER CORE.
20 LGT-120,220,320
L,R L,R
20 LGT- EXTERIOR
UH-1 121
EF-1 121
FPB1B-21 124
SPARE
L
30 DRYER 121 5000
25 CU-1 3952
120/208V 3 4 400A
SIZENO.NO.
INTERRUPTING AMPERE CURRENT
RATING FOR THIS ASSEMBLY
SHALL BE A. RMS SYM.
TOTAL DEMAND
TOTAL CONNECTED
22,000 83,000
83,000 231VA AMPS
B A
CKT.
SIZE
BRKR CKT.LOAD VA LOADBRKR VA
MLO
PANEL NO. D
VA
VOLTAGE PHASE WIRE BUS SIZE MCB
31 32 33 34 35 36 37 38 39 40 41 42
C
B A
C
B A
C
B A
C
B A
C
B A
C
B A
C
RCPT-WASHER 126
DRYER 126
DRYER 126 30 5000
30 5000
30 5000
30 5000
DRYER 126
DRYER 126
DRYER 126
DRYER 126
DRYER 126
DRYER 126
DRYER 126
DRYER 126
DRYER 126
DRYER 126
DRYER 126
DRYER 126
DRYER 126
RCPT-WASHER 126
RCPT-WASHER 126
RCPT-WASHER 126
RCPT-WASHER 126
RCPT-WASHER 126
RCPT-WASHER 126
RCPT-WASHER 126
RCPT-WASHER 126
RCPT-WASHER 126
120/208V 3 4 225A
SIZENO.NO.
INTERRUPTING AMPERE CURRENT
RATING FOR THIS ASSEMBLY
SHALL BE A. RMS SYM. TOTAL DEMAND
TOTAL CONNECTED
22,000
35,500
33,250 92VA AMPS
CKT.
SIZE
BRKR CKT.LOAD VA LOADBRKR VA
MLO
PANEL NO. F
VA
VOLTAGE PHASE WIRE BUS SIZE MCB
PANEL 'G'
B A
31 32 33 34 35 36 37 38 39 40 41 42
C
B A
C
B A
C
B A
C
B A
C
B A
C
B A
C
RCPT-127 (A)20 20
RCPT-127, 127B (B)
A A A A A A A A
A A A A A A
SPARE
SPARE
SPARE
SPARE SPARE
SPARE
SPARE
SPARE
20324
A - CIRCUIT BREAKER TO BE ARC-FAULT CIRCUIT-INTERRUPTER TYPE
(X) - DENOTES TYPICAL SLEEPING ROOM CIRCUIT. SEE ENLARGED ROOM NEW WORK PLAN.
RCPT-129 (A)
RCPT-129, 129B (B)
RCPT-131 (A)
RCPT-131, 131B (B)
RCPT-133 (A)
RCPT-133, 133B (B)
RCPT-128 (A)
RCPT-128, 128B (B)
RCPT-130 (A)
RCPT-130, 130B (B)
RCPT-132 (A)
RCPT-132, 132B (B)
A A
RCPT-134 (A)
RCPT-134, 134B (B)
120/208V 3 4 125A
SIZENO.NO.
INTERRUPTING AMPERE CURRENT
RATING FOR THIS ASSEMBLY
SHALL BE A. RMS SYM.
TOTAL DEMAND
TOTAL CONNECTED
10,000 VA AMPS
B A
CKT.
SIZE
BRKR CKT.LOAD VA LOADBRKR VA
MLO
PANEL NO. G
VA
VOLTAGE PHASE WIRE BUS SIZE MCB
C
B A
C
B A
C
B A
C
SPARE
SPARE
SPARE
SPARE
20,324 18,074 50
RCPT-137 (A)20 20
RCPT-137, 137B (B)
A A A A
A A A
20 FPB-127-134
20 FPB-137-144
A A A A
A A A
A - CIRCUIT BREAKER TO BE ARC-FAULT CIRCUIT-INTERRUPTER TYPE
(X) - DENOTES TYPICAL SLEEPING ROOM CIRCUIT. SEE ENLARGED ROOM NEW WORK PLAN.
B A
C
RCPT-139 (A)
RCPT-139, 139B (B)
RCPT-141 (A)
RCPT-141, 141B (B)
RCPT-143 (A)
RCPT-143, 143B (B)
RCPT-144 (A)
RCPT-144, 144B (B)
RCPT-142 (A)
RCPT-142, 142B (B)
RCPT-140 (A)
RCPT-140, 140B (B)
RCPT-138 (A)
RCPT-138, 138B (B)
120/208V 3 4 225A
SIZENO.NO.
INTERRUPTING AMPERE CURRENT
RATING FOR THIS ASSEMBLY
SHALL BE A. RMS SYM. TOTAL DEMAND
TOTAL CONNECTED
22,000
35,500
33,250 92VA AMPS
CKT.
SIZE
BRKR CKT.LOAD VA LOADBRKR VA
MLO
PANEL NO. H
VA
VOLTAGE PHASE WIRE BUS SIZE MCB
31 32 33 34 35 36 37 38 39 40 41 42
B A
C
B A
C
125 PANEL 'J' 20324
B A
C
B A
C
B A
C
B A
C
B A
C
RCPT-201 (A)20 20
LGT-201, 201B (B)
A A A A A A A A
A A A A A A
RCPT-202 (A)
LGT-202, 202B (B)
RCPT-203 (A)
LGT-203, 203B (B)
RCPT-205 (A)
LGT-205, 205B (B)
RCPT-207 (A)
LGT-207, 207B (B)
RCPT-204 (A)
LGT-204, 204B (B)
RCPT-206 (A)
LGT-206, 206B (B)
RCPT-208 (A)
LGT-208, 208B (B)
A A
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
A - CIRCUIT BREAKER TO BE ARC-FAULT CIRCUIT-INTERRUPTER TYPE
(X) - DENOTES TYPICAL SLEEPING ROOM CIRCUIT. SEE ENLARGED ROOM NEW WORK PLAN.
29610
NO
RT
H CAROL INA
PR
OFESS I ONA L
SEAL
E
N G I N E E
R
R O
B E
R T S C O T T P E R
K I
N S
320-C Midland Parkway, Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF
THE CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING
OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME
CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
NONE
C. COOPER
N. HEBEL
S. PERKINS
INTERIOR & EXTERIOR REPAIRS AT BEQ
M440
ELECTRICAL PANEL SCHEDULES
E-601
141 14528 JULY 2017
60020354
15153G
N40085-17-B-0019
05-17-0019
120/208V 3 4 225A
INTERRUPTING AMPERE CURRENT
RATING FOR THIS ASSEMBLY
SHALL BE A. RMS SYM. TOTAL DEMAND
TOTAL CONNECTED
22,000 VA AMPS
CKT.
SIZE
BRKR CKT.LOAD VA LOADBRKR VA
MLO
PANEL NO. O
VA
VOLTAGE PHASE WIRE BUS SIZE MCB
A- CIRCUIT BREAKER TO BE ARC-FAULT CIRCUIT-INTERRUPTER TYPE
(X)- DENOTES TYPICAL SLEEPING ROOM CIRCUIT. SEE ENLARGED ROOM NEW WORK PLAN.
35,500 33,250 92
31 32 33 34 35 36 37 38 39 40 41 42
B A
C
B A
C
125 PANEL 'P' 20324
B A
C
B A
C
B A
C
B A
C
B A
C
RCPT-301 (A)20 20
LGT-301, 301B (B)
A A A A A A A A
A A A A A A
RCPT-302 (A)
LGT-302, 302B (B)
RCPT-303 (A)
LGT-303, 303B (B)
RCPT-305 (A)
LGT-305, 305B (B)
RCPT-307 (A)
LGT-307, 307B (B)
RCPT-304 (A)
LGT-304, 304B (B)
RCPT-306 (A)
LGT-306, 306B (B)
RCPT-308 (A)
LGT-308, 308B (B)
A A
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
120/208V 3 4 125A
SIZENO.NO.
INTERRUPTING AMPERE CURRENT
RATING FOR THIS ASSEMBLY
SHALL BE A. RMS SYM. TOTAL DEMAND
TOTAL CONNECTED
10,000 VA AMPS
CKT.
SIZE
BRKR CKT.LOAD VA LOADBRKR VA
MLO
PANEL NO. J
VA
VOLTAGE PHASE WIRE BUS SIZE MCB
A- CIRCUIT BREAKER TO BE ARC-FAULT CIRCUIT-INTERRUPTER TYPE
(X)- DENOTES TYPICAL SLEEPING ROOM CIRCUIT. SEE ENLARGED ROOM NEW WORK PLAN.
20,324 18,074 50
18C
B A
C
SPARE
SPARE
SPARE
SPARE
20 FPB-201-208
20 FPB-211-218
B A
C
B A
C
B A
C
B A
20 20
20 20
A A A A 20
A A A A
RCPT-211 (A)
LGT-211, 211B (B)
RCPT-213 (A)
LGT-213, 213B (B)
RCPT-215 (A)
LGT-215, 215B (B)
RCPT-217 (A)
LGT-217, 217B (B)
A A A A A A
RCPT-212 (A)
LGT-212, 212B (B)
RCPT-214 (A)
LGT-214, 214B (B)
RCPT-216 (A)
LGT-216, 216B (B)
RCPT-218 (A)
LGT-218, 218B (B)
A A
120/208V 3 4 225A
SIZENO.NO.
INTERRUPTING AMPERE CURRENT
RATING FOR THIS ASSEMBLY
SHALL BE A. RMS SYM. TOTAL DEMAND
TOTAL CONNECTED
22,000 VA AMPS
CKT.
SIZE
BRKR CKT.LOAD VA LOADBRKR VA
MLO
PANEL NO. K
VA
VOLTAGE PHASE WIRE BUS SIZE MCB
B A
31 32 33 34 35 36 37 38 39 40 41 42
C
B A
C
B A
C
B A
C
B A
C
B A
C
B A
C
RCPT-219-22320 20
AHU-2C 219
RCPT-WASHER 221
DRYER 221
HAND DRYER 222
RCPT-226
RCPT-225,226
RCPT-224 COMM. RACK
L - CIRCUIT BREAKER TO BE LOCK-ON TYPE
35,061 32,811 91
RCPT-EWC 720
20 RCPT-224 COMM. RM. 720
RCPT-224 COMM. RM. 720
RCPT-224 COMM. RM. 360
RCPT-224 COMM. RACK 360
RCPT-224 COMM. RACK 360
LGT-219,221-226
835LGT-EXTERIOR
RCPT-WASHER 221
RCPT-WASHER 221
DRYER 221
DRYER 221
SPARE
SPARE
UH-2 221
EF-2 221
SPARE
SPARE
L
30 5000DRYER 221
30 SPD
120/208V 3 4 225A
SIZENO.NO.
INTERRUPTING AMPERE CURRENT
RATING FOR THIS ASSEMBLY
SHALL BE A. RMS SYM. TOTAL DEMAND
TOTAL CONNECTED
22,000 VA AMPS
CKT.
SIZE
BRKR CKT.LOAD VA LOADBRKR VA
MLO
PANEL NO. L
VA
VOLTAGE PHASE WIRE BUS SIZE MCB
A- CIRCUIT BREAKER TO BE ARC-FAULT CIRCUIT-INTERRUPTER TYPE
(X)- DENOTES TYPICAL SLEEPING ROOM CIRCUIT. SEE ENLARGED ROOM NEW WORK PLAN.
PANEL 'N'
31 32 33 34 35 36 37 38 39 40 41 42
B A
C
B A
C 125 20324
B A
C
B A
C
B A
C
B A
C
B A
C
RCPT-227 (A)20 20
RCPT-227, 227B (B)
A A A A A A A A
A A A A A A
SPARE
SPARE
SPARE
SPARE SPARE
SPARE
SPARE
SPARE
RCPT-229 (A)
RCPT-229, 229B (B)
RCPT-231 (A)
RCPT-231, 231B (B)
RCPT-233 (A)
RCPT-233, 233B (B)
RCPT-228 (A)
RCPT-228, 228B (B)
RCPT-230 (A)
RCPT-230, 230B (B)
RCPT-232 (A)
RCPT-232, 232B (B)
A A
RCPT-234 (A)
RCPT-234, 234B (B)
35,500 33,250 92
120/208V 3 4 125A
SIZENO.NO.
INTERRUPTING AMPERE CURRENT
RATING FOR THIS ASSEMBLY
SHALL BE A. RMS SYM. TOTAL DEMAND
TOTAL CONNECTED
10,000 VA AMPS
CKT.
SIZE
BRKR CKT.LOAD VA LOADBRKR VA
MLO
PANEL NO. N
VA
VOLTAGE PHASE WIRE BUS SIZE MCB
A- CIRCUIT BREAKER TO BE ARC-FAULT CIRCUIT-INTERRUPTER TYPE
(X)- DENOTES TYPICAL SLEEPING ROOM CIRCUIT. SEE ENLARGED ROOM NEW WORK PLAN.
20,324
18C
B A
C
SPARE
SPARE
SPARE
SPARE
20 FPB-227-234
20 FPB-237-244
B A
C
B A
C
B A
C
B A20
20 20
18,074 50
RCPT-237 (A)20 20
RCPT-237, 237B (B)
A A A A
A A A
A A A A
A A A
RCPT-239 (A)
RCPT-239, 239B (B)
RCPT-241 (A)
RCPT-241, 241B (B)
RCPT-243 (A)
RCPT-243, 243B (B)
RCPT-244 (A)
RCPT-244, 244B (B)
RCPT-242 (A)
RCPT-242, 242B (B)
RCPT-240 (A)
RCPT-240, 240B (B)
RCPT-238 (A)
RCPT-238, 238B (B)
120/208V 3 4 225A
SIZENO.NO.
INTERRUPTING AMPERE CURRENT
RATING FOR THIS ASSEMBLY
SHALL BE A. RMS SYM. TOTAL DEMAND
TOTAL CONNECTED
22,000 VA AMPS
CKT.
SIZE
BRKR CKT.LOAD VA LOADBRKR VA
MLO
PANEL NO. R
VA
VOLTAGE PHASE WIRE BUS SIZE MCB
A- CIRCUIT BREAKER TO BE ARC-FAULT CIRCUIT-INTERRUPTER TYPE
(X)- DENOTES TYPICAL SLEEPING ROOM CIRCUIT. SEE ENLARGED ROOM NEW WORK PLAN.
PANEL 'S'
31 32 33 34 35 36 37 38 39 40 41 42
B A
C
B A
C 125 20324
35,500 33,250 92
B A
C
B A
C
B A
C
B A
C
B A
C
RCPT-327 (A)20 20
RCPT-327, 327B (B)
A A A A A A A A
A A A A A A
SPARE
SPARE
SPARE
SPARE SPARE
SPARE
SPARE
SPARE
RCPT-329 (A)
RCPT-329, 329B (B)
RCPT-331 (A)
RCPT-331, 331B (B)
RCPT-333 (A)
RCPT-333, 333B (B)
RCPT-328 (A)
RCPT-328, 328B (B)
RCPT-330 (A)
RCPT-330, 330B (B)
RCPT-332 (A)
RCPT-332, 332B (B)
A A
RCPT-334 (A)
RCPT-334, 334B (B)
120/208V 3 4 225A
SIZENO.NO.
INTERRUPTING AMPERE CURRENT
RATING FOR THIS ASSEMBLY
SHALL BE A. RMS SYM. TOTAL DEMAND
TOTAL CONNECTED
22,000 VA AMPS
CKT.
SIZE
BRKR CKT.LOAD VA LOADBRKR VA
MLO
PANEL NO. Q
VA
VOLTAGE PHASE WIRE BUS SIZE MCB
B A
31 32 33 34 35 36 37 38 39 40 41 42
C
B A
C
B A
C
B A
C
B A
C
B A
C
B A
C
RCPT-319,321-32320 20
AHU-3C 319
RCPT- WASHER 321
DRYER 321
HAND DRYER 322
RCPT-326
RCPT-325, 326
SPARE
SPARE
SPARE
SPARE
SPARE
33,111 30,861 86
RCPT-EWC 720
RCPT-324 360
LGT-319, 321-326
835LGT-EXTERIOR
SPARE
SPARE
RCPT- WASHER 321
RCPT- WASHER 321
DRYER 321
DRYER 321
UH-3 321
EF-3…