ROOFING SCHEDULE OF INDEFINITE QUANTITY WORK - "A"
EXHIBIT A Price for Ordering Period 1
ITEMDESCRIPTIONESTUTUNITEST AMT
NOQTYPRICETOTAL
ROOF :
A001(a)Remove existing mineral surfaced built-up roofing.300SM¥¥0

A001(b) Remove existing sheet waterproof. 50 SM ¥ ¥ 0

A001(c) Remove existing urethane waterproof coating. 50 SM ¥ ¥ 0

A002 Remove existing insulation board. 400 SM ¥ ¥ 0

A003(a) Remove existing asbestos contained mineral surfaced built-up roofing. 300 SM ¥ ¥ 0

A003(b) Remove existing asbestos contained sheet waterproof. 50 SM ¥ ¥ 0

A003(c) Remove existing asbestos contained waterproof coating. 50 SM ¥ ¥ 0

A004 Clean up existing built-up roofing surface by waterblasting. 1,000 SM ¥ ¥ 0

A005 Clean up existing gutter surface by waterblasting. 200 LM ¥ ¥ 0

A006 Cut and remove existing local deteriorated ashalt roofing system and repair them. 100 SM ¥ ¥ 0

A007 Repair existing blister of asphalt roofing system.

50 SM ¥ ¥ 0

A008 Repair existing concrete covering of the slab. 50 LM ¥ ¥ 0

A009 Provide new polymer modified bitumen roofing system with new heat resistant rigid urethane insulation board on existing mineral surfaced built-up roofing. (up to 300SM) 70 SM ¥ ¥ 0

A010 Provide new polymer modified bitumen roofing system with new heat resistant rigid urethane insulation board on existing mineral surfaced built-up roofing. (over 300SM) 350 SM ¥ ¥ 0

A011 Provide new polymer modified bitumen roofing system with new heat resistant rigid urethane insulation board on existing urethane membrane waterproof coating. (up to 300SM) 100 SM ¥ ¥ 0

A012 Provide new polymer modified bitumen roofing system with new heat resistant rigid urethane insulation board on existing urethane membrane waterproof coating. (over 300SM) 350 SM ¥ ¥ 0

A013Provide new polymer modified bitumen roofing system with new heat resistant rigid urethane insulation board on existing concrete slab or concrete covering. (up to 300SM)
100SM¥¥0

A014 Provide new polymer modified bitumen roofing system with new heat resistant rigid urethane insulation board on existing concrete slab or concrete covering. (over 300SM) 350 SM ¥ ¥ 0

A015 Provide new polymer modified bitumen roofing system on existing mineral surfaced built-up roofing. (up to 300SM) 200 SM ¥ ¥ 0

A016 Provide new polymer modified bitumen roofing system on existing mineral surfaced built-up roofing. (over 300SM)

400 SM ¥ ¥ 0

A017Provide new polymer modified bitumen roofing system on existing urethane membrane waterproof coating. (up to 300SM)
100SM¥¥0
A018Provide new polymer modified bitumen roofing system on existing urethane membrane waterproof coating. (over 300SM)
400SM¥¥0

A019 Provide new polymer modified bitumen roofing system on concrete slab or concrete cover. (up to 300SM)

100 SM ¥ ¥ 0

A020 Provide new polymer modified bitumen roofing system on concrete slab or concrete cover. (over 300SM)

400 SM ¥ ¥ 0

A021 Provide new polymer modified bitumen roofing system on existing riser surface.

200 SM ¥ ¥ 0

A022Provide new urethane membrane waterproof coating system on existing mineral surfaced built-up roofing. (up to 300SM)
100SM¥¥0
A023Provide new urethane membrane waterproof coating system on existing mineral surfaced built-up roofing. (over 300SM)
400SM¥¥0
A024Provide new urethane membrane waterproof coating system on existing urethane membrane waterproof coating (up to 300SM).
100SM¥¥0

A025 Provide new urethane membrane waterproof coating system on existing urethane membrane waterproof coating (over 300SM). 400 SM ¥ ¥ 0

A026 Provide new urethane membrane waterproof coating system on existing concrete slab or concrete cover (up to 300SM). 100 SM ¥ ¥ 0

A027 Provide new urethane membrane waterproof coating system on existing concrete surface (over 300SM).

400 SM ¥ ¥ 0

A028Provide new urethane membrane waterproof coating system on existing riser surface.
50SM¥¥0

A029 Provide new urethane membrane waterproof coating system on existing & new concrete structure and foundation surface. 50 SM ¥ ¥ 0

A030 Provide new mineral surfaced built-up roofing for maintenance.

50 SM ¥ ¥ 0

A031Remove existing asphalt shingle roofing system and provide new asphalt shingle roofing system.
100SM¥¥0

A032 Remove existing asbestos contained asphalt shingle roofing & asphalt roofing felt and provide new asphalt shingle roofing & asphalt roofing felt. 100 SM ¥ ¥ 0

A033 Apply heat resistant coating on existing mineral surfaced built-up roofing or urethane membrane waterproof coating surface (up to 300SM).

250 SM ¥ ¥ 0

A034 Apply heat resistant coating on existing mineral surfaced built-up roofing or urethane membrane waterproof coating surface (over 300SM).

1,000 SM ¥ ¥ 0

A035 Provide new polymer modified bitumen roofing system on steel surface of vent pipe.

10 EA ¥ ¥ 0

A036 Remove existing roof tile & asphalt roofing felt and provide new structural plywood, asphalt roofing felt and roof tile on existing sheathing roof board. 100 SM ¥ ¥ 0

A037 Remove existing fascia & gable wood board and provide new wood fascia & gable board.

50 LM ¥ ¥ 0

A038 Provide new 0.6 thk precoated galvanized metal sheet on the existing fascia & gable board.

50 LM ¥ ¥ 0

A039(a) Remove existing metal roof and provide new high profile folded sheet metal roof.

20 SM ¥ ¥ 0

A039(b) Remove existing metal roof and provide new low profile folded sheet metal roof.

30 SM ¥ ¥ 0

A040 Provide new precoated galvanized metal roof on existing metal roof.

30 SM ¥ ¥ 0

A041 Remove existing metal roof fascia & gable and provide new precoated galvanized metal fascia & gable. 30 LM ¥ ¥ 0

A042 Remove existing slate roofing system and provide new slate roofing system. 50 SM ¥ ¥ 0

A043 Remove existing sheet roofing and provide new synthetic polymer roofing system. 50 SM ¥ ¥ 0

A044 Remove existing sheet roofing and provide new synthetic polymer roofing system with new heat resistant rigid insulation board.

70 SM ¥ ¥ 0

A045 Remove existing expansion joint filler & sealant and provide new. 100 LM ¥ ¥ 0

A046 Provide new stainless air ventilator pipe. 10 EA ¥ ¥ 0

A047 Remove existing cement mortar cover and/or various sheet waterproof for existing vent pipe and provide new polymer modified bitumen roofing system around existing vent pipe with stainless tie band.

5 EA ¥ ¥ 0

COPING :

A048(a) Remove existing aluminum coping and provide new aluminum coping.

100 LM ¥ ¥ 0

A048(b) Remove existing PC coping and provide new aluminum coping.

85 LM ¥ ¥ 0

A049 Remove existing aluminum coping temporarily and reinstall existing aluminum coping.

200 LM ¥ ¥ 0

A050(a) Remove existing aluminum expansion cover (up to W=450) and provide new aluminum expansion cover.

70 LM ¥ ¥ 0

A050(b) Remove existing aluminum expansion cover (W=450 ~ 600)and provide new aluminum expansion cover.

100 LM ¥ ¥ 0

FLASHING :

A051 Remove existing metal strap with sealant and provide new aluminum strap with sealant.

100 LM ¥ ¥ 0

A052 Remove existing aluminum strap or flashing with sealant and provide new aluminum frashing with sealant.

100 LM ¥ ¥ 0

A053 Remove existing metal flashing and provide new precoated galvanized frashing of roof edge.

100 LM ¥ ¥ 0

A054 Remove existing metal flashing and provide new aluminum or stainless steel flashing of roof edge.

50 LM ¥ ¥ 0

DRAIN :
A055Remove existing horizontal roof drain strainer with clamping base and provide new copper roof drain and aluminum die-cast strainer.
20EA¥¥0

A056 Remove existing horizontal roof drain strainer with clamping base temporarily. Clean/repaint existing roof drain, strainer and clamping base and reinstall them. 10 EA ¥ ¥ 0

A057 Remove existing vertical roof drain strainer with clamping base and provide new copper roof drain and aluminum die-cast strainer. 20 EA ¥ ¥ 0

A058 Remove existing vertical roof drain strainer with clamping base temporarily. and clean/repaint existing roof drain, strainer and clamping base and reinstall them. 10 EA ¥ ¥ 0

GUTTER AND DOWNSPOUT :

A059 Provide new urethane membrane waterproof coating system on existing cement mortar surface of roof gutter. (up to W=200) 20 LM ¥ ¥ 0

A060 Provide new urethane membrane waterproof coating system on existing cement mortar surface of roof gutter. (W=200~400) 20 LM ¥ ¥ 0

A061 Provide new urethane membrane waterproof coating system on existing cement mortar surface of roof gutter. (over W=400) 20 LM ¥ ¥ 0

A062 Remove existing stainless mesh strainer in the gutter and provide new stainless mesh strainer. 5 EA ¥ ¥ 0

A063(a) Remove existing rain gutter & gutter hanger and provide new PVC gutter & stainless gutter hanger. 50 LM ¥ ¥ 0

A063(b) Remove existing downspout with leader straps and provide new PVC downspout with stainless steel leader straps with splash block. 50 LM ¥ ¥ 0

STEEL SUPPORT & FOUNDATION FOR MECH AND ELEC EQUIPMENT & PIPING :

A064 Remove existing concrete foundation. 3 CM ¥ ¥ 0

A065Remove existing cement mortar and provide new waterproof cement mortar for existing concrete foundation.5SM¥¥0
A066Provide new raised concrete foundation. (300x300~400x400x200H)3EA¥¥0

A067 Provide new raised concrete foundation. (400x400~600x600x300H) 3 EA ¥ ¥ 0

A068 Provide new raised concrete foundation. (over 600x600x300H) 2 EA ¥ ¥ 0

A069 Remove temporarily and reinstall existing mechanical equipment (various capacity A/C outside unit) and concrete block base. Replace existing rubber sheet and anti-vibration rubber with new. 1 EA ¥ ¥ 0

A070 Remove existing electrical conductors and support materials for lightning protection and provide new ones to match existing. 10 EA ¥ ¥ 0

A071 Cut and weld existing steel leg (up to 40x40 angle or up to 40x75 channel) of steel pipe support for mechanical pipe lines (including associated works). Replace existing isolation rubber sheet with new. 10 EA ¥ ¥ 0

A072 Cut and weld existing steel leg (up to 75x75 angle or up to 65x125 channel) of steel pipe support for mechanical pipe lines (including associated works). Replace existing isolation rubber sheet with new. 10 EA ¥ ¥ 0

A073 Cut and weld existing steel leg (over 75x75 angle or up to 65x125 channel) of steel pipe support for mechanical pipe lines (including associated works). Replace existing isolation rubber sheet with new. 10 EA ¥ ¥ 0

A074 Cut and weld existing steel leg (up to 40x40 angle or up to 40x75 channel) of steel pipe support for mechanical pipe lines (including associated works). Replace existing concrete base and isolation rubber sheet with new. 10 EA ¥ ¥ 0

A075 Cut and weld existing steel leg (up to 75x75 angle or up to 65x125 channel) of steel pipe support for mechanical pipe lines (including associated works). Replace existing existing concrete base and isolation rubber sheet with new. 10 EA ¥ ¥ 0

A076 Cut and weld existing steel leg (over 75x75 angle or over 65x125 channel) of steel pipe support for mechanical pipe lines (including associated works). Replace existing existing concrete base and isolation rubber sheet with new. 5 EA ¥ ¥ 0

A077 Remove existing steel leg with concrete base and provide new steel leg support with isolation rubber sheet. 5 EA ¥ ¥ 0

PAINTING :

A078 Paint/Repaint exposed surface of new existing steel & wood surfaces. 20 LM ¥ ¥ 0

A079 Repaint exposed surface of existing lead based paint contained steel surfaces. 20 LM ¥ ¥ 0

TEMPORARY WORK :

A080 Erect and dismantle scaffolding. 500 SM ¥ ¥ 0

ACM SAMPLING:
A081Asbestos sampling of existing roofing material.1EA¥¥0
A082Asbestos sampling of existing roofing material and request sampling analysis.1EA¥¥0

LBP SAMPLING:

A083 Lead based paint sampling of existing steel surface of roof. 1 EA ¥ ¥ 0

A084 Lead based paint sampling of existing steel surface of roof and request sampling analysis. 1 EA ¥ ¥ 0

ACM/LBP ABATEMENT:

A085 Temporary enclosure for asbestos/lead control area. 400 SM ¥ ¥ 0

A086Air, wipe and/or soil sampling and monitoring for asbestos/lead control area.
10EA¥¥0

A087 PCM air sampling and monitoring for asbestos/lead control. 4 EA ¥ ¥ 0

A088 TEM air sampling and monitoring for asbestos/lead control. 4 EA ¥ ¥ 0

A089 Change room for asbestos/lead control area. 2 EA ¥ ¥ 0

A090 Disposal of ACM/LBP. 5 CM ¥ ¥ 0

MISCELLANEOUS WORK :

A091 Replace existing acrylic skylight with new. (600x600)

4 EA ¥ ¥ 0

A092 Replace existing acrylic skylight with new. (900x900)

4 EA ¥ ¥ 0

A093 Replace existing acrylic skylight with new. (1300x1300)

3 EA ¥ ¥ 0

A094 Other related miscellaneous work (must be negotiated at time of order).

1LS¥¥10,000,000
(Not-to-exceed)

TOTAL (A001 through A094) Not-To-Exceed ¥

Abbreviations:
SM = Square Meter, LM = Linear Meter, CM Cubic Meter, EA = Each, LS = Lump Sum, ACM = Asbestos Containing Material, LBP = Lead Based Paint W=width, H=height

&9Roofing and Painting IDIQ Contract for Various Projects (Roofing)

ROOFING AND PAINTING SCHEDULE OF INDEFINITE
QUANTITY WORK&KFF0000IFB N4008421B5500

Amendment 0004

&10ROOFING AND PAINTING SCHEDULE OF INDEFINITY QUANTITY WORK

CUI//FEDCON

PAGE &P

Roofing-B

ROOFING SCHEDULE OF INDEFINITE QUANTITY WORK - "B"
EXHIBIT B Price for Ordering Period 2
ITEMDESCRIPTIONESTUTUNITEST AMT
NOQTYPRICETOTAL
ROOF :
B001(a)Remove existing mineral surfaced built-up roofing.300SM¥¥0

B001(b) Remove existing sheet waterproof. 50 SM ¥ ¥ 0

B001(c) Remove existing urethane waterproof coating. 50 SM ¥ ¥ 0

B002 Remove existing insulation board. 400 SM ¥ ¥ 0

B003(a) Remove existing asbestos contained mineral surfaced built-up roofing. 300 SM ¥ ¥ 0

B003(b) Remove existing asbestos contained sheet waterproof. 50 SM ¥ ¥ 0

B003(c) Remove existing asbestos contained waterproof coating. 50 SM ¥ ¥ 0

B004 Clean up existing built-up roofing surface by waterblasting. 1,000 SM ¥ ¥ 0

B005 Clean up existing gutter surface by waterblasting. 200 LM ¥ ¥ 0

B006 Cut and remove existing local deteriorated ashalt roofing system and repair them. 100 SM ¥ ¥ 0

B007 Repair existing blister of asphalt roofing system.

50 SM ¥ ¥ 0

B008 Repair existing concrete covering of the slab. 50 LM ¥ ¥ 0

B009 Provide new polymer modified bitumen roofing system with new heat resistant rigid urethane insulation board on existing mineral surfaced built-up roofing. (up to 300SM) 70 SM ¥ ¥ 0

B010 Provide new polymer modified bitumen roofing system with new heat resistant rigid urethane insulation board on existing mineral surfaced built-up roofing. (over 300SM) 350 SM ¥ ¥ 0

B011 Provide new polymer modified bitumen roofing system with new heat resistant rigid urethane insulation board on existing urethane membrane waterproof coating. (up to 300SM) 100 SM ¥ ¥ 0

B012 Provide new polymer modified bitumen roofing system with new heat resistant rigid urethane insulation board on existing urethane membrane waterproof coating. (over 300SM) 350 SM ¥ ¥ 0

B013Provide new polymer modified bitumen roofing system with new heat resistant rigid urethane insulation board on existing concrete slab or concrete covering. (up to 300SM)
100SM¥¥0

B014 Provide new polymer modified bitumen roofing system with new heat resistant rigid urethane insulation board on existing concrete slab or concrete covering. (over 300SM) 350 SM ¥ ¥ 0

B015 Provide new polymer modified bitumen roofing system on existing mineral surfaced built-up roofing. (up to 300SM) 200 SM ¥ ¥ 0

B016 Provide new polymer modified bitumen roofing system on existing mineral surfaced built-up roofing. (over 300SM)

400 SM ¥ ¥ 0

B017Provide new polymer modified bitumen roofing system on existing urethane membrane waterproof coating. (up to 300SM)
100SM¥¥0
B018Provide new polymer modified bitumen roofing system on existing urethane membrane waterproof coating. (over 300SM)
400SM¥¥0

B019 Provide new polymer modified bitumen roofing system on concrete slab or concrete cover. (up to 300SM)

100 SM ¥ ¥ 0

B020 Provide new polymer modified bitumen roofing system on concrete slab or concrete cover. (over 300SM)

400 SM ¥ ¥ 0

B021 Provide new polymer modified bitumen roofing system on existing riser surface.

200 SM ¥ ¥ 0

B022Provide new urethane membrane waterproof coating system on existing mineral surfaced built-up roofing. (up to 300SM)
100SM¥¥0
B023Provide new urethane membrane waterproof coating system on existing mineral surfaced built-up roofing. (over 300SM)
400SM¥¥0
B024Provide new urethane membrane waterproof coating system on existing urethane membrane waterproof coating (up to 300SM).
100SM¥¥0

B025 Provide new urethane membrane waterproof coating system on existing urethane membrane waterproof coating (over 300SM). 400 SM ¥ ¥ 0

B026 Provide new urethane membrane waterproof coating system on existing concrete slab or concrete cover (up to 300SM). 100 SM ¥ ¥ 0

B027 Provide new urethane membrane waterproof coating system on existing concrete surface (over 300SM).

400 SM ¥ ¥ 0

B028Provide new urethane membrane waterproof coating system on existing riser surface.
50SM¥¥0

B029 Provide new urethane membrane waterproof coating system on existing & new concrete structure and foundation surface. 50 SM ¥ ¥ 0

B030 Provide new mineral surfaced built-up roofing for maintenance.

50 SM ¥ ¥ 0

B031Remove existing asphalt shingle roofing system and provide new asphalt shingle roofing system.
100SM¥¥0

B032 Remove existing asbestos contained asphalt shingle roofing & asphalt roofing felt and provide new asphalt shingle roofing & asphalt roofing felt. 100 SM ¥ ¥ 0

B033 Apply heat resistant coating on existing mineral surfaced built-up roofing or urethane membrane waterproof coating surface (up to 300SM).

250 SM ¥ ¥ 0

B034 Apply heat resistant coating on existing mineral surfaced built-up roofing or urethane membrane waterproof coating surface (over 300SM).

1,000 SM ¥ ¥ 0

B035 Provide new polymer modified bitumen roofing system on steel surface of vent pipe.

10 EA ¥ ¥ 0

B036 Remove existing roof tile & asphalt roofing felt and provide new structural plywood, asphalt roofing felt and roof tile on existing sheathing roof board. 100 SM ¥ ¥ 0

B037 Remove existing fascia & gable wood board and provide new wood fascia & gable board.

50 LM ¥ ¥ 0

B038 Provide new 0.6 thk precoated galvanized metal sheet on the existing fascia & gable board.

50 LM ¥ ¥ 0

B039(a) Remove existing metal roof and provide new high profile folded sheet metal roof.

20 SM ¥ ¥ 0

B039(b) Remove existing metal roof and provide new low profile folded sheet metal roof.

30 SM ¥ ¥ 0

B040 Provide new precoated galvanized metal roof on existing metal roof.

30 SM ¥ ¥ 0

B041 Remove existing metal roof fascia & gable and provide new precoated galvanized metal fascia & gable. 30 LM ¥ ¥ 0

B042 Remove existing slate roofing system and provide new slate roofing system. 50 SM ¥ ¥ 0

B043 Remove existing sheet roofing and provide new synthetic polymer roofing system. 50 SM ¥ ¥ 0

B044 Remove existing sheet roofing and provide new synthetic polymer roofing system with new heat resistant rigid insulation board.

70 SM ¥ ¥ 0

B045 Remove existing expansion joint filler & sealant and provide new. 100 LM ¥ ¥ 0

B046 Provide new stainless air ventilator pipe. 10 EA ¥ ¥ 0

B047 Remove existing cement mortar cover and/or various sheet waterproof for existing vent pipe and provide new polymer modified bitumen roofing system around existing vent pipe with stainless tie band.

5 EA ¥ ¥ 0

COPING :

B048(a) Remove existing aluminum coping and provide new aluminum coping.

100 LM ¥ ¥ 0

B048(b) Remove existing PC coping and provide new aluminum coping.

85 LM ¥ ¥ 0

B049 Remove existing aluminum coping temporarily and reinstall existing aluminum coping.

200 LM ¥ ¥ 0

B050(a) Remove existing aluminum expansion cover (up to W=450) and provide new aluminum expansion cover.

70 LM ¥ ¥ 0

B050(b) Remove existing aluminum expansion cover (W=450 ~ 600)and provide new aluminum expansion cover.

100 LM ¥ ¥ 0

FLASHING :

B051 Remove existing metal strap with sealant and provide new aluminum strap with sealant.

100 LM ¥ ¥ 0

B052 Remove existing aluminum strap or flashing with sealant and provide new aluminum frashing with sealant.

100 LM ¥ ¥ 0

B053 Remove existing metal flashing and provide new precoated galvanized frashing of roof edge.

100 LM ¥ ¥ 0

B054 Remove existing metal flashing and provide new aluminum or stainless steel flashing of roof edge.

50 LM ¥ ¥ 0

DRAIN :

B055Remove existing horizontal roof drain strainer with clamping base and provide new copper roof drain and aluminum die-cast strainer.
20EA¥¥0

B056 Remove existing horizontal roof drain strainer with clamping base temporarily. Clean/repaint existing roof drain, strainer and clamping base and reinstall them. 10 EA ¥ ¥ 0

B057 Remove existing vertical roof drain strainer with clamping base and provide new copper roof drain and aluminum die-cast strainer. 20 EA ¥ ¥ 0

B058 Remove existing vertical roof drain strainer with clamping base temporarily. and clean/repaint existing roof drain, strainer and clamping base and reinstall them. 10 EA ¥ ¥ 0

GUTTER AND DOWNSPOUT :

B059 Provide new urethane membrane waterproof coating system on existing cement mortar surface of roof gutter. (up to W=200) 20 LM ¥ ¥ 0

B060 Provide new urethane membrane waterproof coating system on existing cement mortar surface of roof gutter. (W=200~400) 20 LM ¥ ¥ 0

B061 Provide new urethane membrane waterproof coating system on existing cement mortar surface of roof gutter. (over W=400) 20 LM ¥ ¥ 0

B062 Remove existing stainless mesh strainer in the gutter and provide new stainless mesh strainer. 5 EA ¥ ¥ 0

B063(a) Remove existing rain gutter & gutter hanger and provide new PVC gutter & stainless gutter hanger. 50 LM ¥ ¥ 0

B063(b) Remove existing downspout with leader straps and provide new PVC downspout with stainless steel leader straps with splash block. 50 LM ¥ ¥ 0

STEEL SUPPORT & FOUNDATION FOR MECH AND ELEC EQUIPMENT & PIPING :

B064 Remove existing concrete foundation. 3 CM ¥ ¥ 0

B065Remove existing cement mortar and provide new waterproof cement mortar for existing concrete foundation.5SM¥¥0
B066Provide new raised concrete foundation. (300x300~400x400x200H)3EA¥¥0
B067Provide new raised concrete foundation. (400x400~600x600x300H)3EA¥¥0
B068Provide new raised concrete foundation. (over 600x600x300H)2EA¥¥0

B069 Remove temporarily and reinstall existing mechanical equipment (various capacity A/C outside unit) and concrete block base. Replace existing rubber sheet and anti-vibration rubber with new. 1 EA ¥ ¥ 0

B070 Remove existing electrical conductors and support materials for lightning protection and provide new ones to match existing. 10 EA ¥ ¥ 0

B071 Cut and weld existing steel leg (up to 40x40 angle or up to 40x75 channel) of steel pipe support for mechanical pipe lines (including associated works). Replace existing isolation rubber sheet with new. 10 EA ¥ ¥ 0

B072 Cut and weld existing steel leg (up to 75x75 angle or up to 65x125 channel) of steel pipe support for mechanical pipe lines (including associated works). Replace existing isolation rubber sheet with new. 10 EA ¥ ¥ 0

B073 Cut and weld existing steel leg (over 75x75 angle or up to 65x125 channel) of steel pipe support for mechanical pipe lines (including associated works). Replace existing isolation rubber sheet with new. 10 EA ¥ ¥ 0

B074 Cut and weld existing steel leg (up to 40x40 angle or up to 40x75 channel) of steel pipe support for mechanical pipe lines (including associated works). Replace existing concrete base and isolation rubber sheet with new. 10 EA ¥ ¥ 0

B075 Cut and weld existing steel leg (up to 75x75 angle or up to 65x125 channel) of steel pipe support for mechanical pipe lines (including associated works). Replace existing existing concrete base and isolation rubber sheet with new. 10 EA ¥ ¥ 0

B076 Cut and weld existing steel leg (over 75x75 angle or over 65x125 channel) of steel pipe support for mechanical pipe lines (including associated works). Replace existing existing concrete base and isolation rubber sheet with new. 5 EA ¥ ¥ 0

B077 Remove existing steel leg with concrete base and provide new steel leg support with isolation rubber sheet. 5 EA ¥ ¥ 0

PAINTING :

B078 Paint/Repaint exposed surface of new existing steel & wood surfaces. 20 LM ¥ ¥ 0

B079 Repaint exposed surface of existing lead based paint contained steel surfaces. 20 LM ¥ ¥ 0

TEMPORARY WORK :

B080 Erect and dismantle scaffolding. 500 SM ¥ ¥ 0

ACM SAMPLING:
B081Asbestos sampling of existing roofing material.1EA¥¥0
B082Asbestos sampling of existing roofing material and request sampling analysis.1EA¥¥0

LBP SAMPLING:

B083 Lead based paint sampling of existing steel surface of roof. 1 EA ¥ ¥ 0

B084 Lead based paint sampling of existing steel surface of roof and request sampling analysis. 1 EA ¥ ¥ 0

ACM/LBP ABATEMENT:

B085 Temporary enclosure for asbestos/lead control area. 400 SM ¥ ¥ 0

B086Air, wipe and/or soil sampling and monitoring for asbestos/lead control area.
10EA¥¥0

B087 PCM air sampling and monitoring for asbestos/lead control. 4 EA ¥ ¥ 0

B088 TEM air sampling and monitoring for asbestos/lead control. 4 EA ¥ ¥ 0

B089 Change room for asbestos/lead control area. 2 EA ¥ ¥ 0

B090 Disposal of ACM/LBP. 5 CM ¥ ¥ 0

MISCELLANEOUS WORK :

B091 Replace existing acrylic skylight with new. (600x600)

4 EA ¥ ¥ 0

B092 Replace existing acrylic skylight with new. (900x900)

4 EA ¥ ¥ 0

B093 Replace existing acrylic skylight with new. (1300x1300)

3 EA ¥ ¥ 0

B094 Other related miscellaneous work (must be negotiated at time of order).

1LS¥¥10,000,000
(Not-to-exceed)

TOTAL (B001 through B094) Not-To-Exceed ¥

Abbreviations:
SM = Square Meter, LM = Linear Meter, CM Cubic Meter, EA = Each, LS = Lump Sum, ACM = Asbestos Containing Material, LBP = Lead Based Paint W=width, H=height
ROOFING AND PAINTING SCHEDULE OF INDEFINITE
QUANTITY WORK&KFF0000IFB N4008421B5500

Amendment 0004

&10ROOFING AND PAINTING SCHEDULE OF INDEFINITY QUANTITY WORK

PAGE &P

Roofing-C

ROOFING SCHEDULE OF INDEFINITE QUANTITY WORK - "C"
EXHIBIT C Price for Ordering Period 3
ITEMDESCRIPTIONESTUTUNITEST AMT
NOQTYPRICETOTAL
ROOF :
C001(a)Remove existing mineral surfaced built-up roofing.300SM¥¥0

C001(b) Remove existing sheet waterproof. 50 SM ¥ ¥ 0

C001(c) Remove existing urethane waterproof coating. 50 SM ¥ ¥ 0

C002 Remove existing insulation board. 400 SM ¥ ¥ 0

C003(a) Remove existing asbestos contained mineral surfaced built-up roofing. 300 SM ¥ ¥ 0

C003(b) Remove existing asbestos contained sheet waterproof. 50 SM ¥ ¥ 0

C003(c) Remove existing asbestos contained waterproof coating. 50 SM ¥ ¥ 0

C004 Clean up existing built-up roofing surface by waterblasting. 1,000 SM ¥ ¥ 0

C005 Clean up existing gutter surface by waterblasting. 200 LM ¥ ¥ 0

C006 Cut and remove existing local deteriorated ashalt roofing system and repair them. 100 SM ¥ ¥ 0

C007 Repair existing blister of asphalt roofing system.

50 SM ¥ ¥ 0

C008 Repair existing concrete covering of the slab. 50 LM ¥ ¥ 0

C009 Provide new polymer modified bitumen roofing system with new heat resistant rigid urethane insulation board on existing mineral surfaced built-up roofing. (up to 300SM) 70 SM ¥ ¥ 0

C010 Provide new polymer modified bitumen roofing system with new heat resistant rigid urethane insulation board on existing mineral surfaced built-up roofing. (over 300SM) 350 SM ¥ ¥ 0

C011 Provide new polymer modified bitumen roofing system with new heat resistant rigid urethane insulation board on existing urethane membrane waterproof coating. (up to 300SM) 100 SM ¥ ¥ 0

C012 Provide new polymer modified bitumen roofing system with new heat resistant rigid urethane insulation board on existing urethane membrane waterproof coating. (over 300SM) 350 SM ¥ ¥ 0

C013Provide new polymer modified bitumen roofing system with new heat resistant rigid urethane insulation board on existing concrete slab or concrete covering. (up to 300SM)
100SM¥¥0

C014 Provide new polymer modified bitumen roofing system with new heat resistant rigid urethane insulation board on existing concrete slab or concrete covering. (over 300SM) 350 SM ¥ ¥ 0

C015 Provide new polymer modified bitumen roofing system on existing mineral surfaced built-up roofing. (up to 300SM) 200 SM ¥ ¥ 0

C016 Provide new polymer modified bitumen roofing system on existing mineral surfaced built-up roofing. (over 300SM)

400 SM ¥ ¥ 0

C017Provide new polymer modified bitumen roofing system on existing urethane membrane waterproof coating. (up to 300SM)
100SM¥¥0
C018Provide new polymer modified bitumen roofing system on existing urethane membrane waterproof coating. (over 300SM)
400SM¥¥0

C019 Provide new polymer modified bitumen roofing system on concrete slab or concrete cover. (up to 300SM)

100 SM ¥ ¥ 0

C020 Provide new polymer modified bitumen roofing system on concrete slab or concrete cover. (over 300SM)

400 SM ¥ ¥ 0

C021 Provide new polymer modified bitumen roofing system on existing riser surface.

200 SM ¥ ¥ 0

C022Provide new urethane membrane waterproof coating system on existing mineral surfaced built-up roofing. (up to 300SM)
100SM¥¥0
C023Provide new urethane membrane waterproof coating system on existing mineral surfaced built-up roofing. (over 300SM)
400SM¥¥0
C024Provide new urethane membrane waterproof coating system on existing urethane membrane waterproof coating (up to 300SM).
100SM¥¥0

C025 Provide new urethane membrane waterproof coating system on existing urethane membrane waterproof coating (over 300SM). 400 SM ¥ ¥ 0

C026 Provide new urethane membrane waterproof coating system on existing concrete slab or concrete cover (up to 300SM). 100 SM ¥ ¥ 0

C027 Provide new urethane membrane waterproof coating system on existing concrete surface (over 300SM).

400 SM ¥ ¥ 0

C028Provide new urethane membrane waterproof coating system on existing riser surface.
50SM¥¥0

C029 Provide new urethane membrane waterproof coating system on existing & new concrete structure and foundation surface. 50 SM ¥ ¥ 0

C030 Provide new mineral surfaced built-up roofing for maintenance.

50 SM ¥ ¥ 0

C031Remove existing asphalt shingle roofing system and provide new asphalt shingle roofing system.
100SM¥¥0

C032 Remove existing asbestos contained asphalt shingle roofing & asphalt roofing felt and provide new asphalt shingle roofing & asphalt roofing felt. 100 SM ¥ ¥ 0

C033 Apply heat resistant coating on existing mineral surfaced built-up roofing or urethane membrane waterproof coating surface (up to 300SM).

250 SM ¥ ¥ 0

C034 Apply heat resistant coating on existing mineral surfaced built-up roofing or urethane membrane waterproof coating surface (over 300SM).

1,000 SM ¥ ¥ 0

C035 Provide new polymer modified bitumen roofing system on steel surface of vent pipe.

10 EA ¥ ¥ 0

C036 Remove existing roof tile & asphalt roofing felt and provide new structural plywood, asphalt roofing felt and roof tile on existing sheathing roof board. 100 SM ¥ ¥ 0

C037 Remove existing fascia & gable wood board and provide new wood fascia & gable board.

50 LM ¥ ¥ 0

C038 Provide new 0.6 thk precoated galvanized metal sheet on the existing fascia & gable board.

50 LM ¥ ¥ 0

C039(a) Remove existing metal roof and provide new high profile folded sheet metal roof.

20 SM ¥ ¥ 0

C039(b) Remove existing metal roof and provide new low profile folded sheet metal roof.

30 SM ¥ ¥ 0

C040 Provide new precoated galvanized metal roof on existing metal roof.

30 SM ¥ ¥ 0

C041 Remove existing metal roof fascia & gable and provide new precoated galvanized metal fascia & gable. 30 LM ¥ ¥ 0

C042 Remove existing slate roofing system and provide new slate roofing system. 50 SM ¥ ¥ 0

C043 Remove existing sheet roofing and provide new synthetic polymer roofing system. 50 SM ¥ ¥ 0

C044 Remove existing sheet roofing and provide new synthetic polymer roofing system with new heat resistant rigid insulation board.

70 SM ¥ ¥ 0

C045 Remove existing expansion joint filler & sealant and provide new. 100 LM ¥ ¥ 0

C046 Provide new stainless air ventilator pipe. 10 EA ¥ ¥ 0

C047 Remove existing cement mortar cover and/or various sheet waterproof for existing vent pipe and provide new polymer modified bitumen roofing system around existing vent pipe with stainless tie band.

5 EA ¥ ¥ 0

COPING :

C048(a) Remove existing aluminum coping and provide new aluminum coping.

100 LM ¥ ¥ 0

C048(b) Remove existing PC coping and provide new aluminum coping.

85 LM ¥ ¥ 0

C049 Remove existing aluminum coping temporarily and reinstall existing aluminum coping.

200 LM ¥ ¥ 0

C050(a) Remove existing aluminum expansion cover (up to W=450) and provide new aluminum expansion cover.

70 LM ¥ ¥ 0

C050(b) Remove existing aluminum expansion cover (W=450 ~ 600)and provide new aluminum expansion cover.

100 LM ¥ ¥ 0

FLASHING :

C051 Remove existing metal strap with sealant and provide new aluminum strap with sealant.

100 LM ¥ ¥ 0

C052 Remove existing aluminum strap or flashing with sealant and provide new aluminum frashing with sealant.

100 LM ¥ ¥ 0

C053 Remove existing metal flashing and provide new precoated galvanized frashing of roof edge.

100 LM ¥ ¥ 0

C054 Remove existing metal flashing and provide new aluminum or stainless steel flashing of roof edge.

50 LM ¥ ¥ 0

DRAIN :

C055Remove existing horizontal roof drain strainer with clamping base and provide new copper roof drain and aluminum die-cast strainer.
20EA¥¥0

C056 Remove existing horizontal roof drain strainer with clamping base temporarily. Clean/repaint existing roof drain, strainer and clamping base and reinstall them. 10 EA ¥ ¥ 0

C057 Remove existing vertical roof drain strainer with clamping base and provide new copper roof drain and aluminum die-cast strainer. 20 EA ¥ ¥ 0

C058 Remove existing vertical roof drain strainer with clamping base temporarily. and clean/repaint existing roof drain, strainer and clamping base and reinstall them. 10 EA ¥ ¥ 0

GUTTER AND DOWNSPOUT :

C059 Provide new urethane membrane waterproof coating system on existing cement mortar surface of roof gutter. (up to W=200) 20 LM ¥ ¥ 0

C060 Provide new urethane membrane waterproof coating system on existing cement mortar surface of roof gutter. (W=200~400) 20 LM ¥ ¥ 0

C061 Provide new urethane membrane waterproof coating system on existing cement mortar surface of roof gutter. (over W=400) 20 LM ¥ ¥ 0

C062 Remove existing stainless mesh strainer in the gutter and provide new stainless mesh strainer. 5 EA ¥ ¥ 0

C063(a) Remove existing rain gutter & gutter hanger and provide new PVC gutter & stainless gutter hanger. 50 LM ¥ ¥ 0

C063(b) Remove existing downspout with leader straps and provide new PVC downspout with stainless steel leader straps with splash block. 50 LM ¥ ¥ 0

STEEL SUPPORT & FOUNDATION FOR MECH AND ELEC EQUIPMENT & PIPING :

C064 Remove existing concrete foundation. 3 CM ¥ ¥ 0

C065 Remove existing cement mortar and provide new waterproof cement mortar for existing concrete foundation. 5 SM ¥ ¥ 0

C066 Provide new raised concrete foundation. (300x300~400x400x200H) 3 EA ¥ ¥ 0

C067 Provide new raised concrete foundation. (400x400~600x600x300H) 3 EA ¥ ¥ 0

C068 Provide new raised concrete foundation. (over 600x600x300H) 2 EA ¥ ¥ 0

C069 Remove temporarily and reinstall existing mechanical equipment (various capacity A/C outside unit) and concrete block base. Replace existing rubber sheet and anti-vibration rubber with new. 1 EA ¥ ¥ 0

C070 Remove existing electrical conductors and support materials for lightning protection and provide new ones to match existing. 10 EA ¥ ¥ 0

C071 Cut and weld existing steel leg (up to 40x40 angle or up to 40x75 channel) of steel pipe support for mechanical pipe lines (including associated works). Replace existing isolation rubber sheet with new. 10 EA ¥ ¥ 0

C072 Cut and weld existing steel leg (up to 75x75 angle or up to 65x125 channel) of steel pipe support for mechanical pipe lines (including associated works). Replace existing isolation rubber sheet with new. 10 EA ¥ ¥ 0

C073 Cut and weld existing steel leg (over 75x75 angle or up to 65x125 channel) of steel pipe support for mechanical pipe lines (including associated works). Replace existing isolation rubber sheet with new. 10 EA ¥ ¥ 0

C074 Cut and weld existing steel leg (up to 40x40 angle or up to 40x75 channel) of steel pipe support for mechanical pipe lines (including associated works). Replace existing concrete base and isolation rubber sheet with new. 10 EA ¥ ¥ 0

C075 Cut and weld existing steel leg (up to 75x75 angle or up to 65x125 channel) of steel pipe support for mechanical pipe lines (including associated works). Replace existing existing concrete base and isolation rubber sheet with new. 10 EA ¥ ¥ 0

C076 Cut and weld existing steel leg (over 75x75 angle or over 65x125 channel) of steel pipe support for mechanical pipe lines (including associated works). Replace existing existing concrete base and isolation rubber sheet with new. 5 EA ¥ ¥ 0

C077 Remove existing steel leg with concrete base and provide new steel leg support with isolation rubber sheet. 5 EA ¥ ¥ 0

PAINTING :

C078 Paint/Repaint exposed surface of new existing steel & wood surfaces. 20 LM ¥ ¥ 0

C079 Repaint exposed surface of existing lead based paint contained steel surfaces. 20 LM ¥ ¥ 0

TEMPORARY WORK :

C080 Erect and dismantle scaffolding. 500 SM ¥ ¥ 0

ACM SAMPLING:
C081Asbestos sampling of existing roofing material.1EA¥¥0
C082Asbestos sampling of existing roofing material and request sampling analysis.1EA¥¥0

LBP SAMPLING:

C083 Lead based paint sampling of existing steel surface of roof. 1 EA ¥ ¥ 0

C084 Lead based paint sampling of existing steel surface of roof and request sampling analysis. 1 EA ¥ ¥ 0

ACM/LBP ABATEMENT:

C085 Temporary enclosure for asbestos/lead control area. 400 SM ¥ ¥ 0

C086Air, wipe and/or soil sampling and monitoring for asbestos/lead control area.
10EA¥¥0

C087 PCM air sampling and monitoring for asbestos/lead control. 4 EA ¥ ¥ 0

C088 TEM air sampling and monitoring for asbestos/lead control. 4 EA ¥ ¥ 0

C089 Change room for asbestos/lead control area. 2 EA ¥ ¥ 0

C090 Disposal of ACM/LBP. 5 CM ¥ ¥ 0

MISCELLANEOUS WORK :

C091 Replace existing acrylic skylight with new. (600x600)

4 EA ¥ ¥ 0

C092 Replace existing acrylic skylight with new. (900x900)

4 EA ¥ ¥ 0

C093 Replace existing acrylic skylight with new. (1300x1300)

3 EA ¥ ¥ 0

C094 Other related miscellaneous work (must be negotiated at time of order).

1LS¥¥10,000,000
(Not-to-exceed)

TOTAL (C001 through C094) Not-To-Exceed ¥

Abbreviations:
SM = Square Meter, LM = Linear Meter, CM Cubic Meter, EA = Each, LS = Lump Sum, ACM = Asbestos Containing Material, LBP = Lead Based Paint W=width, H=height
ROOFING AND PAINTING SCHEDULE OF INDEFINITE
QUANTITY WORK&KFF0000IFB N4008421B5500

Amendment 0004

&10ROOFING AND PAINTING SCHEDULE OF INDEFINITY QUANTITY WORK

PAGE &P

Roofing-Summary

Summary - Roofing Schedule of Indefinite Quantity Work

A-Ordering Period 1 (ELINs A001 through A094)¥
B-Ordering Period 2 (ELINs B001 through B094)¥
C-Ordering Period 3 (ELINs C001 through C094)¥
TOTAL (A through C) Not-To-Exceed¥
ROOFING AND PAINTING SCHEDULE OF INDEFINITE
QUANTITY WORK&KFF0000IFB N4008421B5500