Attachment_2_ELINs-HVAC_J-0200000-07.xls
XLS spreadsheet 1 MB Posted
- Solicitation number
- N4008420R0409
About this file
This sources sought notice requests information from contractors interested in providing preventive maintenance and service orders for heating, ventilating, and air conditioning systems at various locations in the United States Naval Installations at Kanto Plain, Japan. The scope of work includes recurring preventive maintenance programs, non-recurring task work, and unit priced service orders. Interested parties should respond with their technical qualifications and pricing by July 31, 2020. The Naval Facilities Engineering Command will use the responses to determine whether to issue a solicitation for a new multiple-award contract to begin in 2021.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| N4008420R0409 AMENDMENT 00003.pdf | ||
| Attachment_3 20-R-0409-A0003 PWS.pdf | ||
| Attachment_1_Schedule of Price_20200901.pdf | ||
| Amendment 0002_.pdf | ||
| N4008420R0409 AMENDMENT 00001.pdf | ||
| N4008420R0409_SF1449.pdf | ||
| Attachment 5_Pre-Award Inquiry Form.xlsx | XLSX spreadsheet | |
| Attachment 3_Experience and PPQ.pdf | ||
| Attachment 3_Experience and PPQ.docx | DOCX document | |
| Attachment 4_Notices.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S-B
| SCHEDULE OF PRICE | ||||
| NAME OF OFFEROR OR CONTRACTOR: | ||||
| LINE ITEM | ITEM | Q'TY | UNIT | AMOUNT |
| NO. | ||||
| Item 0001 | Recurring, Base Period | 1 | LS | ¥ |
| Provide PM program Services for a period of one year. | ||||
| From 1 September 2020 through 31 March 2021. | ||||
| Item 0002 | Non-Recurring, Base Period | 1 | LS | ¥ |
| Provide Unit Priced Task Work upon receipt of a Task Order. | (NTE) | |||
| From 1 September 2020 through 31 March 2021. | ||||
| Item 0003 | Recurring, First Option Period | 1 | LS | ¥ |
| Provide PM program Services for a period of one year. | ||||
| From 1 April 2021 through 31 March 2022. | ||||
| Item 0004 | Non-Recurring, First Option Period | 1 | LS | ¥ |
| Provide Unit Priced Task Work upon receipt of a Task Order. | (NTE) | |||
| From 1 April 2021 through 31 March 2022. | ||||
| Item 0005 | Recurring, Second Option Period | 1 | LS | ¥ |
| Provide PM program Services for a period of one year. | ||||
| From 1 April 2022 through 31 March 2023. | ||||
| Item 0006 | Non-Recurring, Second Option Period | 1 | LS | ¥ |
| Provide Unit Priced Task Work upon receipt of a Task Order. | (NTE) | |||
| From 1 April 2022 through 31 March 2023. | ||||
| Item 0007 | Recurring, Third Option Period | 1 | LS | ¥ |
| Provide Unit Priced Task Work upon receipt of a Task Order. | ||||
| From 1 April 2023 through 31 March 2024. | ||||
| Item 0008 | Non-Recurring, Third Option Period | 1 | LS | ¥ |
| Provide Unit Priced Task Work upon receipt of a Task Order. | (NTE) | |||
| From 1 April 2023 through 31 March 2024. | ||||
| Item 0009 | Recurring, Fourth Option Period | 1 | LS | ¥ |
| Provide Unit Priced Task Work upon receipt of a Task Order. | ||||
| From 1 April 2024 through 31 March 2025. | ||||
| Item 0010 | Non-Recurring, Fourth Option Period | 1 | LS | ¥ |
| Provide Unit Priced Task Work upon receipt of a Task Order. | (NTE) | |||
| From 1 April 2024 through 31 March 2025. | ||||
| TOTAL: (LINE ITEM 0001 through 0010) | ¥ | |||
| CLIN 9000 | Exhibit A (Base Period) | |||
| CLIN 9001 | Exhibit B (First Option Period) | |||
| CLIN 9002 | Exhibit C (Second Option Period) | |||
| CLIN 9003 | Exhibit D (Third Option Period) | |||
| CLIN 9004 | Exhibit E (Fourth Option Period) | |||
| NOTE: | The number of Placeholders established depends on the maximum number of lines | |||
| of accounting anticipated on an individual task order. | ||||
| Detail line items for task order is located in Attachment J-0200000-07 | ||||
| CLIN = CONTRACT LINE ITEM, LS = LUMP SUM, NTE = NOT-TO-EXCEED | ||||
| Q'TY = QUANTITY | ||||
| If you will use below comments for GE, Print area should be chainge. | ||||
| Note: | GE was formulated based on market research conducted for same or similar items, previous purchases of similar or same items, and experience of technical engineers for this requirement. |
&CB-&P
B-F
| ATTACHMENT J-0200000-07 | |||||||
| EXHIBIT LINE ITEM NUMBERS | |||||||
| SOLICITATION/CONTRACT # | |||||||
| EXHIBIT A - CLIN 9000 | |||||||
| Line Item 0001 Recurring - Base Period | |||||||
| Provide Prices For Facility Investment Services - Recurring - In Accordance With Section C, Spec Item 3 | |||||||
| ELINs A001 through A007 | |||||||
| ELIN /Sub ELIN | Description | Quantity | Unit of Issue | Unit Price | Total | PROPOSAL | TO GE |
| A001 | CNIC | ||||||
| A001-01 | CNIC CFAY PORTION | ||||||
| A001-01-01 | NDK-100134 | ||||||
| A001-01-01-01 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-01-01-02 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-01-01-03 | Scheduled Repair Work for Other HVAC System | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-01-01-04 | Service Order Work Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| MDK-100134 Total, A001-01-01 | ¥ | 0.0% | |||||
| A001-01-02 | YSK-5229 | ||||||
| A001-01-02-01 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-01-02-02 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-01-02-03 | Service Order Work Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-5229 Total, A001-01-02 | ¥ | 0.0% | |||||
| A001-01-03 | YSK-2046 | ||||||
| A001-01-03-01 | Monthly Scheduled PM Work for Automatic Control System Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| A001-01-03-02 | Annual PM Work for Inverter | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-01-03-03 | Service Order Work | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-2046 Total, A001-01-03 | ¥ | 0.0% | |||||
| A001-01-04 | YSK-3816 | ||||||
| A001-01-04-01 | Quarterly PM Work for Dust Collection System Starting from 1 Sep 2020 to 31 Mar 2021 | 2 | LS | ¥ | ¥ | 0.0% | |
| A001-01-04-02 | Quarterly PM Work for Engine Exhaust Removal System Starting from 1 Sep 2020 to 31 Mar 2021 | 2 | LS | ¥ | ¥ | 0.0% | |
| A001-01-04-03 | Annual PM Work for Engine Exhaust Removal System Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-01-04-04 | Service Order Work Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-3816 Total, A001-01-04 | ¥ | 0.0% | |||||
| A001-01-05 | YSK-1558 | ||||||
| A001-01-05-01 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-01-05-02 | Service Order Work Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-1558 Total, A001-01-05 | ¥ | 0.0% | |||||
| A001-01-06 | YSK-3387 | ||||||
| A001-01-06-01 | Monthly On-season Cleaning Work for Cooling Tower Starting from 1 Sep 2020 to 31 Mar 2021 | 3 | MO | ¥ | ¥ | 0.0% | |
| A001-01-06-02 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 2 | LS | ¥ | ¥ | 0.0% | |
| A001-01-06-03 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 (Exception of Absorption Chiller Unit) | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-01-06-04 | Service Order Work | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-3387 Total, A001-01-06 | ¥ | 0.0% | |||||
| A001-01-07 | YSK-4807 | ||||||
| A001-01-07-01 | Semiannual PM Work Starting from from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-01-07-02 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-01-07-03 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-4807 Total, A001-01-07 | ¥ | 0.0% | |||||
| A001-01-08 | YSK-1942 | ||||||
| A001-01-08-01 | Monthly On-season Cleaning Work for Cooling Tower Starting from 1 Sep 2020 to 31 Mar 2021 | 3 | MO | ¥ | ¥ | 0.0% | |
| A001-01-08-02 | Cooling Season-off PM Work for Screw Chiller Unit Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-01-08-03 | Annual PM Work for Screw Chiller Unit Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-01-08-04 | Quarterly PM Work Starting from1 Sep 2020 to 31 Mar 2021 | 2 | LS | ¥ | ¥ | 0.0% | |
| A001-01-08-05 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-01-08-06 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-01-08-07 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-1942 Total, A001-01-08 | ¥ | 0.0% | |||||
| A001-01-09 | YSK-1555 | ||||||
| A001-01-09-01 | Scheduled Repair Work for Absorption Chiller (Base) | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-01-09-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-1555 Total, A001-01-09 | ¥ | 0.0% | |||||
| A001-01-10 | YSK-1997 | ||||||
| A001-01-10-01 | Scheduled Repair Work for Absorption Chiller | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-01-10-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-1997 Total, A001-01-10 | ¥ | 0.0% | |||||
| A001-01-11 | NDK-100137 | ||||||
| A001-01-11-01 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-01-11-02 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | ||
| NDK-100137 Total, A001-11 | ¥ | 0.0% | |||||
| A001-01-12 | YSK-1516 (#9 TOWER) | ||||||
| A001-01-12-01 | Scheduled Repair Work for Absorption Chiller | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-01-12-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-1516 (#9 TOWER) Total, A001-01-12 | ¥ | 0.0% | |||||
| CNIC CFAY Total, A001-01 | ¥ - | 0.0% | |||||
| A001-02 | CNIC-NAVFAC PORTION | ||||||
| A001-02-01 | YSK-4364 | ||||||
| A001-02-01-01 | Scheduled Repair Work for Absorption Chiller (Base) | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-02-01-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-4364 Total, A001-02-01 | ¥ | 0.0% | |||||
| A001-02-02 | YSK-1938 | ||||||
| A001-02-02-01 | Monthly Summer Season Cleaning Work Starting from 1 Sep 2020 to 31 Mar 2021 | 3 | LS | ¥ | ¥ | 0.0% | |
| A001-02-02-02 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-02-02-03 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-02-02-04 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-1938 Total, A001-02-02 | ¥ | 0.0% | |||||
| CNIC NAVFAC Total, A001-02 | ¥ - | 0.0% | |||||
| A001-03 | CNIC-PSEFA PORTION | ||||||
| A001-03-01 | YSK-F69 | ||||||
| A001-03-01-01 | Quarterly PM Work for Air Cooled Module Chiller (C-2) Starting from 1 Sep 2020 to 31 Mar 2021 | 2 | LS | ¥ | ¥ | 0.0% | |
| A001-03-01-02 | Scheduled Repair Work for Air Cooled Module Chiller (C-1, Base) | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-03-01-03 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-F69 Total, A001-01-01 | ¥ | 0.0% | |||||
| CNIC PSEFA Total, A001-03 | ¥ - | 0.0% | |||||
| A001-04 | CNIC-SRF PORTION | ||||||
| A001-04-01 | YSK-A17 | ||||||
| A001-04-01-01 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-01-02 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-01-03 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-A17 Total, A001-04-01 | ¥ | 0.0% | |||||
| A001-04-02 | YSK-A37 | ||||||
| A001-04-02-01 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-02-02 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-02-03 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-A37 Total, A001-04-02 | ¥ | 0.0% | |||||
| A001-04-03 | YSK-A40 | ||||||
| A001-04-03-01 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-03-02 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-03-03 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-A40 Total, A001-04-03 | ¥ | 0.0% | |||||
| A001-04-04 | YSK-A46 | ||||||
| A001-04-04-01 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-04-02 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-04-03 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-A46 Total, A001-04-04 | ¥ | 0.0% | |||||
| A001-04-05 | YSK-A47 | ||||||
| A001-04-05-01 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-05-02 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-05-03 | Once Three (3) Years Replacment Work of Parts for FDC-2 Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-05-04 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-A47 Total, A001-04-05 | ¥ | 0.0% | |||||
| A001-04-06 | YSK-A48 | ||||||
| A001-06-06-01 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-06-06-02 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-06-06-03 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-A48 Total, A001-04-06 | ¥ | 0.0% | |||||
| A001-04-07 | YSK-A61 | ||||||
| A001-04-07-01 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-07-02 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-07-03 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-A61 Total, A001-04-07 | ¥ | 0.0% | |||||
| A001-04-08 | YSK-A82 | ||||||
| A001-04-08-01 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-08-02 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-A82 Total, A001-04-08 | ¥ | 0.0% | |||||
| A001-04-09 | YSK-1649 | ||||||
| A001-04-09-01 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-09-03 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-1649 Total, A001-04-09 | ¥ | 0.0% | |||||
| A001-04-10 | YSK-1922 | ||||||
| A001-04-10-01 | Monthly On-season Cleaning Work for Cooling Tower Starting from 1 Sep 2020 to 31 Mar 2021 | 3 | MO | ¥ | ¥ | 0.0% | |
| A001-04-10-02 | Quarterly PM PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 2 | LS | ¥ | ¥ | 0.0% | |
| A001-04-10-03 | Cooling Season-off PM Work for Screw Ciller Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-10-04 | Annual PM Work for Screw Ciller Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-10-05 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 2 | LS | ¥ | ¥ | 0.0% | |
| A001-04-10-06 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-10-07 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-1922 Total, A001-04-10 | ¥ | 0.0% | |||||
| A001-04-11 | YSK-2043 | ||||||
| A001-04-11-01 | Scheduled Repair Work for Absorption Chiller | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-11-02 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-11-03 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 (Exception of Absorption Chiller Unit) | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-11-04 | Inicial Repair Work for Draft Chambers Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-11-05 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-2043 Total, A001-04-11 | ¥ | 0.0% | |||||
| A001-04-12 | YSK-2053 | ||||||
| A001-04-12-01 | Monthly On-season Cleaning Work for Cooling Tower Starting from 1 Sep 2020 to 31 Mar 2021 | 3 | MO | ¥ | ¥ | 0.0% | |
| A001-04-12-02 | Cooling Season-off PM Work for Screw Chiller Unit Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-12-03 | Annual PM Work for Screw Chiller Unit Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-12-04 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-12-05 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-12-06 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-2053 Total, A001-04-12 | ¥ | 0.0% | |||||
| A001-04-13 | YSK-2067 | ||||||
| A001-04-13-01 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-13-02 | Annual PM Work Starting from to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-13-03 | Once three (3) Years Replacement Work of parts for FE-19, 20 & FS-5 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-13-04 | Quartely PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 2 | LS | ¥ | ¥ | 0.0% | |
| A001-04-13-05 | Service Order Starting from to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-2067 Total, A001-04-13 | ¥ | 0.0% | |||||
| A001-04-14 | YSK-2068 | ||||||
| A001-04-14-01 | Monthly On-season Cleaning Work for Cooling Tower Starting from 1 Sep 2020 to 31 Mar 2021 | 3 | MO | ¥ | ¥ | 0.0% | |
| A001-04-14-02 | Scheduled Repair Work for Absorption Chiller Unit | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-14-03 | Quarterly PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 2 | LS | ¥ | ¥ | 0.0% | |
| A001-04-14-04 | Semiannual PM Work | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-14-05 | Annual PM Work (Exception of Absorption Chiller Unit) Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-14-06 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-2068 Total, A001-04-14 | ¥ | 0.0% | |||||
| A001-04-15 | YSK-2078 | ||||||
| A001-04-15-01 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-15-02 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-04-15-03 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-2078 Total, A001-04-15 | ¥ | 0.0% | |||||
| CNIC SRF Total, A001-04 | ¥ | ||||||
| A001-05 | CNIC MWR CATEGORY A PORTION | ||||||
| A001-05-01 | YSK-3008 | ||||||
| A001-05-01-01 | Scheduled Repair Work for Absorption Chiller Unit (Base) | 2 | LS | ¥ | ¥ | 0.0% | |
| A001-05-01-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-3008 Total, A001-05-01 | ¥ | 0.0% | |||||
| A001-05-02 | YSK-3354 | ||||||
| A001-05-02-01 | Biennial PM Work for Absorption Chiller | 2 | LS | ¥ | ¥ | 0.0% | |
| A001-05-02-02 | Scheduled Repair Work for Absorption Chiller (RA-2) | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-05-02-03 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-3354 Total, A001-05-02 | ¥ | 0.0% | |||||
| A001-05-03 | YSK-3365 | ||||||
| A001-05-03-01 | Scheduled Repair Work for Absorption Chiller (Base) | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-05-03-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-3365 Total, A001-05-03 | ¥ | 0.0% | |||||
| CNIC MWR CATEGORY A Total, A001-05 | ¥ - | 0.0% | |||||
| A001-06 | CNIC MWR CATEGORY C PORTION | ||||||
| A001-06-01 | YSK-1493 | ||||||
| A001-06-01-01 | Scheduled Repair Work for Water Cooled Screw Chiller Unit | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-06-01-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-1493 Total, A001-06-01 | ¥ | 0.0% | |||||
| MWR CATEGORY C Total, A001-06 | ¥ - | 0.0% | |||||
| A001-07 | CNIC MWR OTHER NAF PORTION | ||||||
| A001-07-01 | YSK-3316 | ||||||
| A001-07-01-01 | Scheduled Repair Work for Absorption Chiller Unit | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-07-01-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-3316 Total, A001-07-01 | ¥ | 0.0% | |||||
| A001-07-02 | YSK-H20 | ||||||
| A001-07-02-01 | Scheduled Repair Work for Absorption Chiller (Base) | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-07-02-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-H20 Total, A001-07-02 | ¥ | 0.0% | |||||
| A001-07-03 | YSK-4849 (Cold Storage) | ||||||
| A001-07-03-01 | Scheduled Repair Work for Chiller (Base) | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-07-03-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-4849 Total, A001-07-03 | ¥ | 0.0% | |||||
| A001-07-04 | YSK-1390 (Cold Storage) | ||||||
| A001-07-04-01 | Scheduled Repair Work for Chiller (Base) | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-07-04-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-1390 Total, A001-07-04 | ¥ | 0.0% | |||||
| MWR OTHER NAF PORTION Total, A001-07 | ¥ - | 0.0% | |||||
| A001-08 | CNIC NEX PORTION | ||||||
| A001-08-01 | YSK-F157 | ||||||
| A001-08-01-01 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-08-01-02 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A001-08-01-03 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-F157 Total, A001-08-01 | ¥ | 0.0% | |||||
| CNIC NEX PORTION Total, A001-08 | ¥ - | 0.0% | |||||
| CNIC PORTION Total, A001 | ¥ - | 0.0% | |||||
| A002 | SRF PORTION | ||||||
| A002-01 | Land Crane (LC) at YSK-DD4, 5, 6 &YSK-B8, 12 | ||||||
| A002-01-01 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A002-01-02 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A002-01-03 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| LC Total, A002-01 | ¥ | 0.0% | |||||
| A002-02 | CAVE-439 | ||||||
| A002-02-01 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A002-02-02 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ - | ¥ | 0.0% | |
| CAVE-439 Total, A002-03 | ¥ | 0.0% | |||||
| A002-03 | CAVE-444 | ||||||
| A002-03-01 | Quaterly PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 2 | LS | ¥ | ¥ | 0.0% | |
| A002-03-02 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| CAVE-444 Total, A002-18 | ¥ | 0.0% | |||||
| A002-04 | Icemaker | ||||||
| A002-04-01 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A002-04-02 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ - | ¥ | 0.0% | |
| Icemaker Total, A002-04 | ¥ | 0.0% | |||||
| SRF Total, A002 | ¥ - | 0.0% | |||||
| A003 | DLA PORTION | ||||||
| A003-01 | YSK-J39 | ||||||
| A003-01-01 | Monthly PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| A003-01-02 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A003-01-03 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A003-01-04 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-J39 Total, A003-01 | ¥ | 0.0% | |||||
| A003-02 | YSK-J164 | ||||||
| A003-02-01 | Monthly PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| A003-02-02 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A003-02-03 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-J164 Total, A003-02 | ¥ | 0.0% | |||||
| A003-03 | YSK-4831 | ||||||
| A003-03-01 | Scheduled Repair Work for Absorption Chiller (Base) | 1 | LS | ¥ | ¥ | 0.0% | |
| A003-03-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-4831 Total, A003-03 | ¥ | 0.0% | |||||
| DLA Total, A003 | ¥ - | 0.0% | |||||
| A004 | USNH PORTION | ||||||
| A004-01 | YSK-1401 | ||||||
| A004-02-01 | Monthly PM Work for Cooling Towers Including Water Examination Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| A004-02-02 | Winter Season-in PM Work for Air Cooled Water Chiller Unit Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A004-02-03 | Winter Season-on PM Work for Air Cooled Water Chiller Unit Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A004-02-04 | Winter Season-off PM Work for Air Cooled Water Chiller Unit Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A004-02-05 | Annual PM Work for Air Cooled Water Chiller Unit Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A004-02-06 | Semiannual PM Work for HVAC System Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A004-02-07 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-1401 Total, A004-01 | ¥ | 0.0% | |||||
| A004-02 | Air Balance Inspection (YSK-1400 & 3008) | ||||||
| A004-02-01 | Semiannual Air Balance Inspection Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| Air Balance Inspection Total, A004-02 | ¥ | 0.0% | |||||
| UNSH Total, A004 | ¥ - | 0.0% | |||||
| A005 | DODDS PORTION | ||||||
| A005-01 | YSK-1903 | ||||||
| A005-01-01 | Scheduled Repair Work for Absorption Chiller Unit | 1 | LS | ¥ | ¥ | 0.0% | |
| A005-01-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-1903 Total, A005-01 | ¥ | 0.0% | |||||
| A005-02 | YSK-3858 | ||||||
| A005-02-01 | Scheduled Repair Work for Absorption Chiller | 1 | LS | ¥ | ¥ | 0.0% | |
| A005-02-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-3858 Total, A005-02 | ¥ | 0.0% | |||||
| A005-03 | YSK-3859 | ||||||
| A005-03-01 | Scheduled Repair Work for Absorption Chiller | 1 | LS | ¥ | ¥ | 0.0% | |
| A005-03-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-3859 Total, A005-03 | ¥ | 0.0% | |||||
| A005-04 | IKE-824 | ||||||
| A005-04-01 | Quarterly PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 2 | LS | ¥ | ¥ | 0.0% | |
| A005-04-02 | Semiannual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A005-04-03 | Annual PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A005-04-04 | Once Three (3) Years Replacement Work of Filters for AHU-5~7 | 1 | LS | ¥ | ¥ | 0.0% | |
| A005-04-05 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| IKE-824 Total, A005-04 | ¥ | 0.0% | |||||
| DODDS Total, A005 | ¥ - | 0.0% | |||||
| A006 | NCTS PORTION | ||||||
| A006-01 | YSK-1942 | ||||||
| A006-01-01 | Quarterly PM Work Starting from 1 Sep 2020 to 31 Mar 2021 | 2 | LS | ¥ | ¥ | 0.0% | |
| A006-01-02 | Annual PM Work for Absorption Chiller Starting from 1 Sep 2020 to 31 Mar 2021 | 1 | LS | ¥ | ¥ | 0.0% | |
| A006-01-03 | Service Order Starting from 1 Sep 2020 to 31 Mar 2021 | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-1942 Total, A006-01 | ¥ | 0.0% | |||||
| NCTS Total, A006 | ¥ | 0.0% | |||||
| A007 | HOUSING PORTION | ||||||
| A007-01 | YSK-1152 (#1 TOWER) | ||||||
| A007-01-01 | Scheduled Repair Work for Absorption Chiller | 1 | LS | ¥ | ¥ | 0.0% | |
| A007-01-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-1152 (#1 TOWER) Total, A007-01 | ¥ | 0.0% | |||||
| A007-02 | YSK-1151 (#2 TOWER) | ||||||
| A007-02-01 | Scheduled Repair Work for Absorption Chiller | 1 | LS | ¥ | ¥ | 0.0% | |
| A007-02-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-1151 (#2 TOWER) Total, A007-02 | ¥ | 0.0% | |||||
| A007-03 | YSK-1150 (#3 TOWER) | ||||||
| A007-03-01 | Scheduled Repair Work for Absorption Chiller | 1 | LS | ¥ | ¥ | 0.0% | |
| A007-03-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-1150 (#3 TOWER) Total, A007-03 | ¥ | 0.0% | |||||
| A007-04 | YSK-1149 (#4 TOWER) | ||||||
| A007-04-01 | Scheduled Repair Work for Absorption Chiller | 1 | LS | ¥ | ¥ | 0.0% | |
| A007-04-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-1149 (#4 TOWER) Total, A007-04 | ¥ | 0.0% | |||||
| A007-05 | YSK-1148 (#5 TOWER) | ||||||
| A007-05-01 | Scheduled Repair Work for Absorption Chiller | 1 | LS | ¥ | ¥ | 0.0% | |
| A007-05-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-1148 (#5 TOWER) Total, A007-05 | ¥ | 0.0% | |||||
| A007-06 | YSK-1147 (#6 TOWER) | ||||||
| A007-06-01 | Scheduled Repair Work for Absorption Chiller | 1 | LS | ¥ | ¥ | 0.0% | |
| A007-06-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-1147 (#6 TOWER) Total, A007-06 | ¥ | 0.0% | |||||
| A007-07 | YSK-1315 (#7 TOWER) | ||||||
| A007-07-01 | Scheduled Repair Work for Absorption Chiller | 1 | LS | ¥ | ¥ | 0.0% | |
| A007-07-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-1315 (#7 TOWER) Total, A007-07 | ¥ | 0.0% | |||||
| A007-08 | YSK-1316 (#8 TOWER) | ||||||
| A007-08-01 | Scheduled Repair Work for Absorption Chiller | 1 | LS | ¥ | ¥ | 0.0% | |
| A007-08-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-1316 (#8 TOWER) Total, A007-08 | ¥ | 0.0% | |||||
| A007-09 | YSK-3826 (FUJI) | ||||||
| A007-09-01 | Scheduled Repair Work for Absorption Chiller | 1 | LS | ¥ | ¥ | 0.0% | |
| A007-09-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-3826 (FUJI) Total, A007-10 | ¥ | 0.0% | |||||
| A007-10 | YSK-4447 | ||||||
| A007-10-01 | Scheduled Repair Work for Absorption Chiller | 1 | LS | ¥ | ¥ | 0.0% | |
| A007-10-02 | Service Order | 7 | MO | ¥ | ¥ | 0.0% | |
| YSK-4447 Total, A007-10 | ¥ | 0.0% | |||||
| Housing Total, A007 | ¥ - | 0.0% | |||||
| BASE PERIOD RECURRING LINE ITEMS TOTAL | ¥ | 0.0% | |||||
| LS= | Lump Sum | ||||||
| MO = | Monthly | ||||||
| LS = | Time |
SECTION J
EXHIBIT A
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Reconditioning and Maintenance Service for Barbwire Fence.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Reconditioning and Maintenance Service for Ornamental Steel Fence.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Reconditioning and Maintenance Service for Wood Fence.
PROVIDE A UNIT PRICE FOR THE REMOVAL AND DISPOSAL OF FENCE COMPLETE, FENCE POSTS, BARBWIRE, BARBED TAPE.
IN ACCORDANCE WITH SECTION C, C.10.1.l
ELIN A001EW through A001FI Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Removal Service for Chain link Fence.
Including Fabric, Posts, Gates, Rails, Tension Wire, Barbwire/Barbed Tape.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Removal Service for Chain link Fence Gates including tracks (not posts).
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Removal Service for Ornamental Steel Fence. Including Posts and Gates Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Removal Service for Wood Fence. Including Posts and Gates.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Removal Service for Barbwire Fence. Including Posts and all wire.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Each to Provide Removal Service for Fence Posts. Including Posts Footing with Braces and Supports as Required.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Each to Provide Removal Service for Fence Posts. Post Cut-off Flush.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Each to Provide Removal Service for Fence Posts. Driven Post.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Each to Provide Removal Service for Fence Posts. Including Posts Footing with Braces and Supports as Required.
Posts Set in Concrete/Asphalt.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Square Foot to Patch and Refinish Concrete or Asphalt Surface.
Surface Depth to Match Surrounding.
Unit Price Each to Remove and Dispose of or Save and Store (for reuse) Barbwire Single Arm Support.
Unit Price Each to remove and Dispose of or Save and Store (for reuse) Barbwire Double (V) Arm Support.
Lump Sum Price for the recycling of removed materials. Based on a Percentage Added to Removal Item Ordered
SECTION J
EXHIBIT A
Lump Sum Price for the Recycling of Removed Materials. Based on a Percentage Added to Removal Item Ordered, ELIN A001EK to A001EW. Figured on a Quantity of 1,000. The Quantity Provided is for Establishing the Percentage Rate Only.
PROVIDE A UNIT PRICE TO PERFORM EXPEDITED SERVICES.
IN ACCORDANCE WITH SECTION C, C.10.2
ELIN A001FJ
Lump Sum Price for Expedited Maintenance and Repair Services. Based on a Percentage Added to Task Order Total. Figured on a Quantity of 1,000. The Quantity Provided is for Establishing the Percentage Rate Only.
SECTION J
EXHIBIT A
SECTION J
EXHIBIT A
PROVIDE A UNIT PRICE FOR THE RENTAL OF TEMPORARY CHAIN LINK FENCE.
IN ACCORDANCE WITH SECTION C, C.10.3
ELIN A001FK THROUGH A001FP
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Temporary Chain link Fence.
6' Fence Height Driven Posts Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Temporary Chain link Fence.
12' Panel, 6' Height Driven Posts Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Temporary Chain link Fence.
12' Panel, 6' Height, Free-Standing Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Temporary Chain link Fence.
Driven Posts With Barbwire, 7' Fence Height Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Temporary Chain link Fence.
12' Panel, With Barbwire, 7' Height Driven Posts Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Temporary Chain link Fence.
12' Panel, With Barbwire, 7' Height, Free-Standing
B-IQ
| ATTACHMENT J-0200000-07 | |||||||||
| EXHIBIT LINE ITEM NUMBERS | |||||||||
| SOLICITATION/CONTRACT # | |||||||||
| EXHIBIT A - CLIN 9000 | |||||||||
| Line Item 0002 None Recurring Price - Base Period | |||||||||
| PROVIDE PRICES FOR FACILITY INVESTMENT - INDEFINITE DELIVERY / INDEFINITE QUANTITY - IN ACCORDANCE WITH SECTION C, | |||||||||
| SPEC ITEM 4 | |||||||||
| ELINs A700 through A755 | |||||||||
| ELIN | Product Name | Description Extended | Estimated Quantity | Unit of Issue | Unit Price | Extended Price | IMAP CAC | Proposal | Gap |
| A700 | Major Repair Work (Negotiated) | Major Repair Work is consist of direct labor cost, direct material cost, and indirect cost such as transportation, disposal, report and overhead profit used in IDIQ work. Performance of specific maintenance, repair, and alteration work that exceeds the FFP limitations of a service call or PM repair. Task order completion times will be specified in task order. | 1 | LS | 0% | ||||
| A701 | Inspect Air Balance At One (1) Room in YSK-1400 and 3008. | The Contractor shall inspect air balance at one (1) room, and notify actual air flow and balance to the Government immediately. If the air balance is out of designated balance, the Government will adjust air volume. The Contractor shall inspect actual air balance again. Repeat those processes until the air balance meets the designed specifications, not to exceed two (2) days in the Government regular working hours since the start of the initial inspection. The Contractor shall submit the final actual air balance report to the Government within seven (7) calendar days after the site inspection is completed. | 10 | LS | ¥ - | ¥ - | 0% | ||
| A702 | Replace The Existing OA Pre-Filters for FS-9 at Paint Booth in Room114 of YSK-2078. | The Contractor shall replace the existing OA pre-filters (4EA) with new ones. The existing OA filters to be replaced is 750 x 500 x 20t (PS-600). The Contractor shall dispose the removed filters. The Contractor shall be completed the replacement work within 21 calendar days after the date of order. | 4 | LS | ¥ - | ¥ - | 0% | ||
| A703 | Replace The Existing OA Pre-Filters for FS-9 at Paint Booth in Room114 of YSK-2078. | The Contractor shall replace the existing OA pre-filters (16EA) with new ones. The existing OA filters to be replaced is 500 x 500 x 20t (PS-600). The Contractor shall dispose the removed filters. The Contractor shall be completed the replacement work within 21 calendar days after the date of order. | 4 | LS | ¥ - | ¥ - | 0% | ||
| A704 | Replace The Existing Supply Filters for FE-22 at Paint Booth in Room114 of YSK-2078. | The Contractor shall replace the existing supply filters (39EA) with new ones. The existing supply filters to be replaced is 610 x 610 x 20t (PS-400). The Contractor shall dispose the removed filters. The Contractor shall be completed the replacement work within 21 calendar days after the date of order. | 8 | LS | ¥ - | ¥ - | 0% | ||
| A705 | Replace The Existing Exhaust Filters for FE-22 at Paint Booth in Room114 of YSK-2078. | The Contractor shall replace the existing exhaust filters (39EA) with new ones. The existing exhaust filters to be replaced is 610 x 610 x 20t (PS-400). The Contractor shall dispose the removed filters. The Contractor shall be completed the replacement work within 21 calendar days after the date of order. | 8 | LS | ¥ - | ¥ - | 0% | ||
| A706 | Replace The Existing Exhaust Filters for FE-125 & FO-125 at Room 125 & 126 of YSK-2068. | The Contractor shall replace the existing exhaust filters (10EA) with new ones. The existing exhaust filters to be replaced is 500 x 500 x 50t (Cool Pat). The Contractor shall dispose the removed filters. The Contractor shall be completed the replacement work within 21 calendar days after the date of order. | 9 | LS | ¥ - | ¥ - | 0% | ||
| A707 | Replace Diaphragm Valves of Fume Collection unit (FDC-2) at YSK- A47. | Replace existing diaphragm valves (25A, AC200V: 7ea) of fume collection unit (FCD-2) at YSK- A47 with new ones. Replacement work shall be completed within 40 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A708 | Replace Manometer and Filter Regulator of Fume Collection unit (FDC-2) at YSK- A47. | Replace existing manometer (0 to 5kPa: 1ea) and filter regulator of fume collection unit (FCD-2) at YSK- A47 with new ones. Replacement work shall be completed within 40 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A709 | Replace Pulse Shock Controller of Fume Collection unit (FDC-2) at YSK- A47. | Replace existing pulse shock controller (HMG-10: 1ea) of fume collection unit (FCD-2) at YSK- A47 with new ones. Replacement work shall be completed within 40 calendar days after the date of order. | 1 | EA | ¥ - | ¥ - | 0% | ||
| A710 | Replace Metal Filters, Casters and Clamps of Fume Collection unit (FDC-2) at YSK- A47. | Replace existing metal filters (300x300: 16ea), Casters (Ø40: 16ea) and clamps (8ea) of fume collection unit (FCD-2) at YSK- A47 with new ones. Replacement work shall be completed within 40 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A711 | Replace CO2 Fire Extinguish Equipments of Fume Collection unit (FDC-2) at YSK- A47. | Replace existing CO2 cylinders (IHP13.4L/8.9kg: 2ea), FE tube (20M) with fittings (1 LS), protection springs (6M: 3ea) and starting parts of fume collection unit (FCD-2) at YSK- A47 with new ones. Replacement work shall be completed within 40 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A712 | Replace Differential Manometer of Bag Filter Unit for Dust Collection Unit (AFE-1) at YSK- 2078. | Replace existing differential manometer (MU-500: 1 ea) and related parts of bag filter unit (AFE-1) at YSK- 2078 with new ones. Replacement work shall be completed within 45 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A713 | Replace Fan Bearings of Inducted Draft Fan for Dust Collection Unit (AFE-1) at YSK- 2078. | Replace existing fan bearings (#6318: 2ea) of inducted draft fan for dust collection unit (AFE-1) at YSK- 2078 with new ones. Replacement work shall be completed within 45 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A714 | Replace Vibration Isolation Joints of Inducted Draft Fan for Dust Collection Unit (AFE-1) at YSK- 2078. | Replace existing vibration isolation joints (Ø1200 x 250L: 1 ea, Ø1250 x 950 x 150L: 1ea) of inducted draft fan for dust collection unit (AFE-1) at YSK- 2078 with new ones. Replacement work shall be completed within 45 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A715 | Replace Motor Bearings of Inducted Draft Fan for Dust Collection Unit (AFE-1) at YSK- 2078. | Replace existing motor bearings (#NU220CM: 1ea, #6318: 1ea) of inducted draft fan for dust collection unit (AFE-1) at YSK- 2078 with new ones. Replacement work shall be completed within 45 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A716 | Overhaul Compressor for Dust Collection System (AFE-1) at YSK- 2078. | Overhaul compressor for dust collection system (AFE-1) at YSK- 2078. Overhauling work shall be completed within 60 calendar days after the date of order. | 2 | LS | ¥ - | ¥ - | 0% | ||
| A717 | Replace Motor of Motor Damper for Dust Collection Unit (AFE-1) at YSK- 2078. | Replace existing motor of motor damper (MH-01: 1ea) for dust collection unit (AFE-1) at YSK- 2078 with new one. Replacement work shall be completed within 75 calendar days after the date of order. | 1 | EA | ¥ - | ¥ - | 0% | ||
| A718 | Overhaul Outside Air Supply Fan (FS-8) at YSK- 2078. | Replace existing fan bearings, motor bearings, V-pulleys (Fan and motor) and V-belts for outside air supply fan (FS-8) at YSK- 2078 with new ones. Replacement work shall be completed within 30 calendar days after the date of order. | 2 | LS | ¥ - | ¥ - | 0% | ||
| A719 | Overhaul Outside Air Supply Fan (FS-9) at YSK- 2078. | Replace existing fan bearings, motor bearings, V-pulleys (Fan and motor) and V-belts for outside air supply fan (FS-9) at YSK- 2078 with new ones. Replacement work shall be completed within 30 calendar days after the date of order. | 4 | LS | ¥ - | ¥ - | 0% | ||
| A720 | Overhaul Exhaust Air Fan (FE-22) at YSK- 2078. | Replace existing fan bearings, motor bearings, V-pulleys (Fan and motor) and V-belts for exhaust air fan (FE-22) at YSK- 2078 with new ones. Replacement work shall be completed within 30 calendar days after the date of order. | 4 | LS | ¥ - | ¥ - | 0% | ||
| A721 | Overhaul Outside Air Supply Fan (FS-2, 3) at YSK- 2078. | Replace existing fan bearings, motor bearings, V-pulleys (Fan and motor) and V-belts for outside air supply fan (FS-2, 3) at YSK- 2078 with new ones. Replacement work shall be completed within 30 calendar days after the date of order. | 2 | LS | ¥ - | ¥ - | 0% | ||
| A722 | Overhaul Exhaust Air Fan (FE-20) at YSK- 2078. | Replace existing fan bearings, motor bearings, V-pulleys (Fan and motor) and V-belts for exhaust air fan (FE-20) at YSK- 2078 with new ones. Replacement work shall be completed within 30 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A723 | Overhaul Outside Air Supply Fan (FS-4) at YSK- 2078. | Replace existing fan bearings, motor bearings, V-pulleys (Fan and motor) and V-belts for outside air supply fan (FS-2, 3) at YSK- 2078 with new ones. Replacement work shall be completed within 30 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A724 | Overhaul Exhaust Air Fan (FE-4) at YSK- 2078. | Replace existing fan bearings, motor bearings, V-pulleys (Fan and motor) and V-belts for exhaust air fan (FE-4) at YSK- 2078 with new ones. Replacement work shall be completed within 30 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A725 | Replace 50A 2-Way Motor Control Valve for Steam Supply/Return System at YSK- 2078 | Replace existing 50A 2 way motor control valve including actuator for steam supply/return system at YSK- 2078 with new ones. Replacement work shall be completed within 60 calendar days after the date of order. | 2 | EA | ¥ - | ¥ - | 0% | ||
| A726 | Replace 80A 2-Way Motor Control Valve for Steam Supply/Return System at YSK- 2078 | Replace existing 80A 2 way motor control valve including actuator for steam supply/return system at YSK- 2078 with new ones. Replacement work shall be completed within 60 calendar days after the date of order. | 2 | EA | ¥ - | ¥ - | 0% | ||
| A727 | Replace Differential Manometers of Bag Filter Unit for Dust Collection Unit (AFE-2) at YSK- 2078. | Replace existing differential manometers (MU-500: 1 ea) and related parts of bag filter unit (AFE-2) at YSK- 2078 with new ones. Replacement work shall be completed within 45 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A728 | Replace Fan Bearings of Inducted Draft Fan for Dust Collection Unit (AFE-2) at YSK- 2078. | Replace existing fan bearings (#6318: 4ea) of inducted draft fan for dust collection unit (AFE-2) at YSK- 2078 with new ones. Replacement work shall be completed within 45 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A729 | Replace Vibration Isolation Joints of Inducted Draft Fan for Dust Collection Unit (AFE-2) at YSK- 2078. | Replace existing vibration isolation joints (Ø850 x 250L: 1 ea, Ø770 x 640 x 150L: 1ea) of inducted draft fan for dust collection unit (AFE-2) at YSK- 2078 with new ones. Replacement work shall be completed within 45 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A730 | Replace Motor Bearings of Inducted Draft Fan for Dust Collection Unit (AFE-2) at YSK- 2078. | Replace existing motor bearings (#6315ZZ: 1ea, #6312ZZ: 1ea) of inducted draft fan for dust collection unit (AFE-1) at YSK- 2078 with new ones. Replacement work shall be completed within 45 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A731 | Overhaul Compressor for Dust Collection System (AFE-2) at YSK- 2078. | Overhaul compressor for dust collection system (AFE-2) at YSK- 2078. Overhauling work shall be completed within 60 calendar days after the date of order. | 2 | LS | ¥ - | ¥ - | 0% | ||
| A732 | Replace Differential Monometers for One Hepa Filter Unit at YSK- 1922. | Replace existing differential manometers (0~500Pa) of high efficiency filter side for one heap filter unit at YSK- 1922 with new one. Replacement work shall be completed within 40 calendar days after the date of order. | 1 | EA | ¥ - | ¥ - | 0% | ||
| A733 | Replace Differential Monometers for one Hepa Filter Unit at YSK- 1922. | Replace existing differential manometers (0~300Pa) of middle efficiency filter side for one heap filter unit at YSK- 1922 with new one. Replacement work shall be completed within 40 calendar days after the date of order. | 1 | EA | ¥ - | ¥ - | 0% | ||
| A734 | Replace Fan Bearings, Motor Bearings, V-Belts and V-Pulleys of One Ventilation Fan at YSK- 1922 | Replace existing fan bearings, motor bearings, v-belts and v-pulleys for one ventilation fan at YSK- 1922 with new one. Replacement work shall be completed within 45 calendar days after the date of order. | 2 | LS | ¥ - | ¥ - | 0% | ||
| A735 | Replace Fan Bearings, Motor Bearings, V-Belts and V-Pulleys of One Ventilation Fan (FE-1) at YSK- A47. | Replace existing fan bearings, motor bearings, v-belts and v-pulleys for one ventilation fan (FE-1) at YSK- A47 with new one. Replacement work shall be completed within 45 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A736 | Replace Fan Bearings, Motor Bearings, V-Belts and V-Pulleys of One Ventilation Fan (FE-2) at YSK- A47. | Replace existing fan bearings, motor bearings, v-belts and v-pulleys for one ventilation fan (FE-2) at YSK- A47 with new one. Replacement work shall be completed within 45 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A737 | Replace Fan Bearings, Motor Bearings, V-Belts and V-Pulleys of One Ventilation Fan (FE-1) at YSK- A48. | Replace existing fan bearings, motor bearings, v-belts and v-pulleys for one ventilation fan (FE-1) at YSK- A48 with new one. Replacement work shall be completed within 45 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A738 | Replace Fan Bearings, Motor Bearings, V-Belts and V-Pulleys of One Ventilation Fan (FE-2) at YSK- A48. | Replace existing fan bearings, motor bearings, v-belts and v-pulleys for one ventilation fan (FE-2) at YSK- A48 with new one. Replacement work shall be completed within 45 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A739 | Replace Sliding Damper of Mist Collection unit (FED-3) at YSK- 2043. | Replace existing sliding damper (Ø200 x 150L) of mist collection unit (FED-3) at YSK- 2043 with new ones. Replacement work shall be completed within 60 calendar days after the date of order. | 1 | EA | ¥ - | ¥ - | 0% | ||
| A740 | Replace Manometer of Mist Collection unit (FED-3) at YSK- 2043. | Replace existing manometer (1ea: WO-81) of mist collection unit (FED-3) at YSK- 2043 with new ones. Replacement work shall be completed within 60 calendar days after the date of order. | 1 | EA | ¥ - | ¥ - | 0% | ||
| A741 | Overhaul Ventilation fan of Mist Collection unit (FED-3) at YSK- 2043. | Replace existing fan bearings (2ea: #6308ZZ), motor bearings (2ea: 6308ZZ, #6306ZZ), V-belts (2ea: 3V-600), V-pulley (2ea: Ø100, Ø140) and canvas joints (Ø310x250L) at YSK- 2043 with new ones. Replacement work shall be completed within 60 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A742 | Replace Manometer of Fume Collection unit (FED-1) at Bldg. 2043. | Replace existing manometer (MO-81: 1ea) fume collection unit (FED-1) at Bldg. 2043 with new ones. Replacement work shall be completed within 60 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A743 | Replace Sliding gate of Fume Collection unit (FED-1) at Bldg. 2043. | Replace existing sliding gate (Ø200 x 150L) of fume collection unit (FED-1) at Bldg. 2043 with new ones. Replacement work shall be completed within 60 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A744 | Overhaul Fan of Fume Collection unit (FED-1) at Bldg. 2043. | Replace existing motor bearings (#6207: 1ea, #6305: 1ea), impeller (Ø200 x 80L) and vibration isolation rubbers (Ø165 x 300L) of fume collection unit (FED-1) at Bldg. 2043 with new ones. Replacement work shall be completed within 60 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A745 | Overhaul Outside Air Supply Fan (FS-113) for Paint Booth System at YSK- 2043. | Replace existing fan bearings, motor bearings, V-pulleys (Fan and motor) and V-belts for outside air supply fan (FS-113) for paint booth system at YSK- 2043 with new ones. Replacement work shall be completed within 30 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A746 | Overhaul Outside Air Supply Fan (FS-220) for Paint Booth System at YSK- 2043. | Replace existing fan bearings, motor bearings, V-pulleys (Fan and motor) and V-belts for outside air supply fan (FS-220) for paint booth system at YSK- 2043 with new ones. Replacement work shall be completed within 30 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A747 | Overhaul Outside Air Supply Fan (FO-125) for Paint Booth System at YSK- 2068. | Replace existing fan bearings, motor bearings, V-pulleys (Fan and motor) and V-belts for outside air supply fan (FS-220) for paint booth system at YSK- 2068 with new ones. Replacement work shall be completed within 60 calendar days after the date of order. | 2 | LS | ¥ - | ¥ - | 0% | ||
| A748 | Overhaul Ventilation Fan (FE-125) for Paint Booth System at YSK- 2068. | Replace existing fan bearings, motor bearings, V-pulleys (Fan and motor) and V-belts for ventilation fan (FE-125) for paint booth system at YSK- 2068 with new ones. Replacement work shall be completed within 60 calendar days after the date of order. | 2 | LS | ¥ - | ¥ - | 0% | ||
| A749 | Overhaul Ventilation Fan (FE-1) for Injection Ventilation system at YSK- J418. | Replace existing fan bearings, motor bearings, V-pulleys (Fan and motor) and V-belts for ventilation fan (FE-1) for injection ventilation system at YSK- J418 with new ones. Replacement work shall be completed within 30 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A750 | Replace V-Belts Outside Air Supply Fan (FS-113) for Paint Booth System at YSK- 2043. | Replace existing V-belts for outside air supply fan (FS-113) for paint booth system at YSK- 2043 with new ones. Replacement work shall be completed within 30 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A751 | Replace V-Belts Outside Air Supply Fan (FS-220) for Paint Booth System at YSK- 2043. | Replace existing V-belts for outside air supply fan (FS-220) for paint booth system at YSK- 2043 with new ones. Replacement work shall be completed within 30 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A752 | Replace V-Belts Outside Air Supply Fan (FO-125) for Paint Booth System at YSK- 2068. | Replace existing V-belts for outside air supply fan (FS-220) for paint booth system at YSK- 2068 with new ones. Replacement work shall be completed within 60 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A753 | Replace V-Belts Ventilation Fan (FE-125) for Paint Booth System at YSK- 2068. | Replace existing V-belts for ventilation fan (FE-125) for paint booth system at YSK- 2068 with new ones. Replacement work shall be completed within 60 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A754 | Replace V-Belts Ventilation Fan (FE-1) for Injection Ventilation system at YSK- J418. | Replace existing V-belts for ventilation fan (FE-1) for injection ventilation system at YSK- J418 with new ones. Replacement work shall be completed within 30 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| A755 | Clean Exterior Duct Surfaces at Room 112 in Sand Blast Room of YSK-2078. | Clean exterior duct surfaces at Room 112 in sand blast room of YSK-2078. Top of duct is approximately 8.5m high from floor level. Total cleaning area is approximately 50 square meters. Site plan is provided in Attachment J-1502000-09-002-15, Page 21 of 21. The Contractor shall complete the cleaning work within 21 calendar days after the date of order. | 1 | LS | ¥ - | ¥ - | 0% | ||
| TOTAL IDIQ PRICE | ¥ - | 0% | |||||||
| TM= | Time | ||||||||
| LS= | Lump Sum | ||||||||
| EA= | Each |
1-F
| ATTBCHMENT J-0200000-07 | |||||||
| EXHIBIT LINE ITEM NUMBERS | |||||||
| SOLICITBTION/CONTRBCT # | |||||||
| EXHIBIT B - CLIN 9001 | |||||||
| Line Item 0003 Recurring - First Option Period | |||||||
| Provide Prices For Facility Investment Services - Recurring - In Accordance With Section C, Spec Item 3 | |||||||
| ELINs B001 through B007 | |||||||
| ELIN /Sub ELIN | Description | Quantity | Unit of Issue | Unit Price | Total | PROPOSAL | TO GE |
| B001 | CNIC | ||||||
| B001-01 | CNIC CFAY PORTION | ||||||
| B001-01-01 | NDK-100134 | ||||||
| B001-01-01-01 | Semiannual PM Work | 2 | LS | ¥ | ¥ | 0.0% | |
| B001-01-01-02 | Annual PM Work | 1 | LS | ¥ | ¥ | 0.0% | |
| B001-01-01-03 | Service Order Work | 12 | MO | ¥ | ¥ | 0.0% | |
| MDK-100134 Total, B001-01-01 | ¥ | 0.0% | |||||
| B001-01-02 | YSK-5229 | ||||||
| B001-01-02-01 | Semiannual PM Work | 2 | LS | ¥ | ¥ | 0.0% | |
| B001-01-02-02 | Annual PM Work | 1 | LS | ¥ | ¥ | 0.0% | |
| B001-01-02-03 | Service Order Work | 12 | MO | ¥ | ¥ | 0.0% | |
| YSK-5229 Total, B001-01-02 | ¥ | 0.0% | |||||
| B001-01-03 | YSK-2046 | ||||||
| B001-01-03-01 | Monthly Scheduled PM Work for Automatic Control System | 12 | MO | ¥ | ¥ | 0.0% | |
| B001-01-03-02 | Cooling Season-in PM Work for Absorption Chiller | 1 | LS | ¥ | ¥ | 0.0% | |
| B001-01-03-03 | Cooling Season-on PM Work for Absorption Chiller | 1 | LS | ¥ | ¥ | 0.0% | |
| B001-01-03-04 | Cooling Season-off PM Work for Absorption Chiller | 1 | LS | ¥ | ¥ | 0.0% |
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .