Section_J_Part4.pdf

PDF 4 MB Posted

Attached to
Facility Support Contract for NY Consolidation (Newburgh, Syracuse, Brooklyn, Red Bank)
Solicitation number
N4008314R1015
Issued by

About this file

Section J - Part 4 (Specification Pkg)

View the file

Other files

File Type Posted
Section_L.pdf PDF
WD_Brooklyn.pdf PDF
WD_Syracuse.pdf PDF
Section_C.pdf PDF
SF33_RFP.pdf PDF
Section_J_Part1.pdf PDF
WD_Red_Bank.pdf PDF
Section_J_Part3.pdf PDF
Solicitation_Description.pdf PDF
ELINS_(Final).xls XLS spreadsheet
Safety_Talking_Points.pdf PDF
Financial_Verification.pdf PDF
WD_Orange.pdf PDF
Section_J_Part2.pdf PDF
PPQ.pdf PDF
Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT J-1503010-03

Custodial Service Floor Plan

MCRTC Red Bank, NJ

Basement level

First Floor

Second Floor

J-1503010-04

CUSTODIAL SERVICE LEVELS

MARFORRES Custodial Service Frequencies Frequency by Service Level

Spec Item

Work Item A B C D

3.1.1 Space Cleaning

3.1.1.1 Emptying Waste Containers 3W W W M

3.1.1.2 Low Area Cleaning M M Q Q

3.1.1.3 Employee Mess Area Cleaning D 2W W 2M

3.1.1.4 High Area Cleaning Q SA SA A

3.1.1.5 Interior Glass Cleaning W W M M

3.1.1.6 Interior/Exterior Window Cleaning A A A A

3.1.1.7 Window Blinds Cleaning A A A A

3.1.1.8 Exercise Area Cleaning D 2W W 2M

3.1.2 Floor Care

3.1.2.1 Sweeping and Dust Mopping 3W W 2M M

3.1.2.2 Vacuum Carpets and Rugs W W 2M M

3.1.2.3 Cleaning Walk-off Mats W W M M

3.1.2.4 Spray Cleaning and Buffing M M Q SA

3.1.2.5 Damp Mopping W W M M

3.1.2.6 Stripping, Coating, and Buffing SA SA A A

3.1.2.7 Carpet and Rug Deep Cleaning SA SA SA SA

3.1.3 Restroom Services

3.1.3.1 Restroom Cleaning D 2W W 2M

3.1.3.2 Restroom Supplies D 2W W 2M

3.1.4 Building Perimeter Services

3.1.4.1 Debris Removal W 2M M M

3.1.4.2 Empty Perimeter Waste Containers W 2M M M

KEY

D Daily 3W Three times per week 2W Two times per week W One time per week 2M Two times per month M One time per month Q Four times per year SA Two times per year A One time per year

ATTACHMENT J-1503020-01

DEFINITIONS AND ACRONYMS

Pest Control Performance Assessment Representative

(PCPAR)

A DoD employee trained in pest management, who protects the government's interest through on-site performance assessment (PA) of commercial pest management contracts or other contracts that involve the use of pesticides.

Pest Management The prevention and control of disease vectors and pests that may adversely affect the DoD mission or military operations; the health and well being of people; or structures, material, or property.

Professional Pest Management Consultant (PPMC)

A professional, with a degree in a biological science, who has rigorous college-level entomology training, such as a NAVFACENGCOM civilian entomologist (applied biologist) or Bureau of Medicine and Surgery (BUMED) commissioned medical entomologist who has command program oversight responsibilities and provides guidance and information on the management of pest management programs for commands and installations.

Pesticide Any substance or mixture of substances, including biological control agents, registered by EPA under FIFRA intended to destroy, repel, or mitigate pests. Includes insecticides, rodenticides, herbicides, fungicides, plant regulators, defoliants, desiccants, disinfectants, anti-fouling paints, and biocides (such as water treatment chemicals). NAVFACENGCOM pest management consultants do not approve disinfectants or biocides.

Pesticide Facility The building and areas designated for handling, storing, and mixing of pesticides.

Pests Any organism (except for micro-organisms that cause human or animal diseases) that adversely affects operations, preparedness, the well being of humans or animals, real property, materiel, equipment or vegetation, or is otherwise undesirable.

Registered Pesticide

A pesticide registered by EPA for sale and use within the United States.

Road Mile/Kilometer

A unit of measure for measuring fogging application for adult mosquito control using a vehicle mounted Ultra Low Volume (ULV) aerosol generator traveling along a given route for a distance of 5,280 feet/1,000 meters.

Surveillance Thorough inspections or surveys conducted before or after pest management treatments or on a regular basis to determine the presence and prevalence of pests or disease vectors.

Time Period to Maintain Control

A frequency specified on each Pest Group Sheet that is the minimum time the Contractor shall maintain control of pest(s) after reaching the specified level of control.

Time Period to Obtain Control

A frequency specified on each Pest Group Sheet that is the maximum time allotted for the Contractor to obtain control of pest(s) per the specified level of control.

Time Period to Respond

A frequency specified on each Pest Group Sheet that is the maximum time the Contractor is permitted to respond to a trouble call.

ATTACHMENT J-1503020-02

PLANNED PESTICIDE USE SHEET

USER GUIDE FOR PLANNED PESTICIDE USE SHEET

This is the User Guide for completing the Planned Pesticide Use Sheet that contains:

(1) Instructions for completing the Planned Pesticide Use Sheet

(2) List of Acceptable Terms

(3) Planned Pesticide Use Sheet Blank Form

The Planned Pesticide Use Sheet shall be included as part of the Contractor’s Work Plan (CWP) for Pest Control.

One “Planned Pesticide Use Sheet” shall be filled out for each pest that will be controlled with a pesticide. If more than one pesticide is used to control the pest, one sheet shall be filled out for each of the pesticides used per pest.

These forms shall be filled out on-line if the on-line reporting system is used. The link to the system is:

https://clients.emainc.com/PestManagementNET/PesticideLogon.aspx. The regional NAVFAC Professional Pest Management Consultant should be contacted to obtain a password and instructions to use the system. A new Planned Pesticide Use Sheet shall be filled out whenever pesticides used to control a pest are added or changed.

The List of Acceptable Terms shall be used to complete the Planned Pesticide Use Sheet (see Step 3A). Completed Planned Pesticide Use Sheets shall be attached to the CWP.

https://clients.emainc.com/PestManagementNET/PesticideLogon.aspx

INSTRUCTIONS FOR COMPLETING THE PLANNED PESTICIDE USE SHEET

The following is a list of instructions for filling out each line of information required on the Planned Pesticide Use Sheet:

1. INSTALLATION, UIC - Insert the name and Unit Identification Code for the installation. The UIC is a five-digit number preceded by an “N" for Navy installations and an “M” for Marine Corps installations. The UIC is available from the KO.

2. APPLICATOR: Insert the name of the individual(s) who will be applying the pesticide.

3. OBJECTIVE

A. TARGET PEST - The name of the pest or pests identified for control. Select the proper pest or pest category from the List of Acceptable Terms.

B. PURPOSE - Explaing the major reason(s) for controlling the target pest(s) Refer to the List of Acceptable Terms.

4. PESTICIDE

A. TRADE NAME – Insert the manufacturer’s name given to the product, e.g., TermidorTM and MaxforceTM , both trade names for fipronil.

B. COMMON NAME - Insert the common or popular name (as opposed to the chemical name).

C. EPA REGISTRATION NUMBER – Insert the number usually found on the front of the label and on the container.

D. FORMULATION – Insert the form that the pesticide is in when ready for use. Refer to the List of Acceptable Terms.

E. CONC ACTIVE INGREDIENT - Insert the percent active ingredient of the pesticide before it is mixed with a diluent. This information should be on the front of the label.

5. APPLICATION

A. USE % - Insert the percent final concentration of the pesticide to be applied.

B. DILUENT – Insert the liquid that is used to dilute the pesticide, e.g., water, oil. If undiluted, indicate, "None".

C. RATE – Insert the quantity of pesticide that will be applied per unit of measure, e.g., 4 pounds per acre; 1 bait per 10 linear feet; 2 gallons per 100 square feet; 2 ounces per minute.

D. METHOD – Insert the method of application, e.g., by hand, power sprayer, ULV generator, compressed air sprayer.

INSTRUCTIONS FOR COMPLETING THE PLANNED PESTICIDE USE SHEET

E. UNITS TREATED – Identify total quantity treated, e.g., total acres, square feet, linear feet if known. Insert "Varies" if not a definite quantity.

F. SITE – Identify the specific site where the pesticide will be applied. Refer to the List of Acceptable Terms.

G. MONTHS – Insert the time period during which the pest control work will be performed, e.g., a specific month(s), season, or year round.

6. SENSITIVE AREAS – Identify areas to be avoided or where special caution should be taken. Refer to the “Caution and Warning” statements on the label.

7. INSPECTION METHODS - Identify the method and frequency of inspections, e.g., a cockroach inspection includes the monthly use of a flashlight, a flushing agent and roach sticky traps, or, an inspection for mole crickets on the golf course includes a walk-through evaluation every 3 days.

8. OTHER CONTROLS – Identify other pesticides or methods of control that are used to control the particular pest, e.g., biological control, mechanical control, preventive measures.

9. REMARKS – Include any additional pertinent information. If a general pest category has been listed under Target Pest, the specific pests should be listed here.

LIST OF ACCEPTABLE TERMS FOR PLANNED PESTICIDE USE SHEETS

TARGET PEST TARGET PEST TARGET PEST

ALGAE FLEAS SCALE INSECTS

ALGAE/AQUATIC WEEDS FUNGUS SNAKES

ANTS FUNGUS - PYTHIUM SOD WEBWORMS

ARMY WORMS GRASS SPIDERS

BAHAI GRASS GRUBS STORED PRODUCTS PESTS

BATS HOUSEHOLD PESTS STRUCTURAL PESTS

BEETLES LICE TERMITES-DRYWOOD

BIRDS MEDICAL PESTS TERMITES-FORMOSAN

BITING FLIES MICE TERMITES-SUBTERRANEAN

CARPENTER ANTS MITES TICKS

CATERPILLARS MOLE CRICKETS TURF DISEASE

CHIGGERS MOLES TURF PESTS

CHINCH BUGS MOSQUITO ADULTS TURF/ORNAMENTAL PESTS

COCKROACHES MOSQUITO LARVAE WASPS

CRAB GRASS NEMATODES WEEDS – ALL

CRICKETS NUISANCE PESTS WEEDS – AQUATIC

CULICOIDES ORNAMENTAL PESTS WEEDS - BROADLEAVED

EARWIGS PHARAOH ANTS WEEDS – GRASSY

FERAL ANIMALS - PIGEONS WHITEFLIES

FILTH FLIES RATS WOODY VEGETATION

FIRE ANTS RODENTS

PURPOSE PURPOSE PURPOSE

APPEARANCE LAWN/TURF PESTS SAFETY

APPEARANCE/DRAINAGE LAWN/TURF PROTECTION SECURITY

BARE GROUND MAINTENANCE STING PREVENTION

BARE GROUND/SECURITY MEDICAL SURVEILLANCE

DECREASE MOWING NUISANCE TURF APPEARANCE

DISEASE VECTOR NUISANCE/DISEASE VECTOR TURF MAINTENANCE

DRAINAGE NUISANCE/HEALTH TURF PROTECTION

HEALTH PROTECTION NUISANCE/MEDICAL WILD LIFE MANAGEMENT

HEALTH/NUISANCE PREVENT STRUCTURAL DAMAGE

LAWN/TURF DAMAGE PROTECT ORNAMENTAL PLANTS

LIST OF ACCEPTABLE TERMS FOR PLANNED PESTICIDE USE SHEETS (cont’d)

FORMULATION FORMULATION FORMULATION

AEROSOL FUMIGANT SUSPENSION

AQUEOUS SOLUTION GEL TABLETS

BAIT BLOCKS GRANULES TRACKING POWDER

BAIT PACK LIQUID ULD SOLUTION

BAIT STATIONS LIQUID FUMIGANT ULV CONCENTRATE

BAITS PASTE/GLUE ULV SOLUTION

BRIQUETS PELLETS WATER SOLUBLE

CAKE (RODENT) POWDER WETTABLE GRANULES

CAPSULES REPELLENT WETTABLE POWDER

CONCENTRATE RESIN STRIPS

DISPERSIBLE GRANULES SOLID FUMIGANT

DRY FLOWABLE SOLUBLE POWDER

DUST SOLUTION

EMULSION STRIPS/TAPE

FLOWABLE POWDER

SITE SITE SITE

ADMIN/OFFICE FOOD WAREHOUSE OUTDOOR AREAS

ALL BUILDINGS FOOD-HANDLING AREAS OUTSIDE AREAS

ALL OUTDOOR AREAS FORESTS PAVEMENT/ROADS

BARRACKS GOLF COURSE PONDS

BUILDING EXTERIORS GREENHOUSE RIGHT-OF-WAYS"

BUILDING INTERIORS GROUND APPLICATION RIVERS/STREAMS

BUILDINGS HANGAR SPOIL AREAS

CANALS HOSPITAL/MEDICAL STANDING WATER

CHILDCARE CENTER IMPROVED AREAS STRUCTURES

CROPLAND INDUSTRIAL AREAS TREES

DITCHES KENNELS TURF

DUMPSTERS LAKES TURF PROTECTION

ELECTRICAL BOXES LAWNS UNIMPROVED AREAS

ELECTRONIC EQUIPMENT LAWNS - FAMILY HOUSING UTILITY BUILDINGS

FAMILY QUARTERS MANHOLES UTILITY RIGHT OF WAY

FENCELINES MATERIAL STORAGE WAREHOUSES - FOOD

FLOWER BEDS ORNAMENTAL PLANTS WAREHOUSES-NONFOOD

FOOD STORAGE AREAS

BLANK FORM

INSTALLATION NAME:

UIC:

APPLICATOR:

TARGET PEST:

PURPOSE:

TRADE NAME:

COMMON NAME:

EPA REG NO:

FORMULATION :

CONC AI :

USE %:

DILUENT:

RATE:

METHOD:

UNITS TREATED:

SITE:

MONTHS:

SENSITIVE AREAS:

INSPECTION METHOD(S):

OTHER CONTROLS:

REMARKS:

ATTACHMENT J-1503020-03

REFERENCES AND TECHNICAL DOCUMENTS

The Contractor shall adhere to the applicable portions of the current edition of the following publications and directives in performing the services required under this contract:

• Armed Forces Pest Management Board TG No. 11, Hydrogen Phosphide Fumigation of Subsistence with Aluminum Phosphide

• Armed Forces Pest Management Board TG No. 14, Protective Equipment for Pest Control Personnel

• Armed Forces Pest Management Board TG No. 15, Pesticide Spill Prevention and Management

• Armed Forces Pest Management Board TG No. 27, Stored-Product Pest Monitoring Methods

• Armed Forces Pest Management Board TG No. 29, Integrated Pest Management In and Around Buildings

• Armed Forces Pest Management Board TG No. 37, Guidelines for Reducing Feral/Stray Cat Populations on Military Installations in the United States

• Department of Defense Directive 4150.07 , Department of Defense Pest Management Program

• Executive Order 12088, Prevention, Control, and Abatement of Environmental Pollution at Federal Installations

• Federal Aviation Regulation, Part 137, Agricultural Aircraft Operations

• OPNAV Instruction 6250.4C, Navy Pest Management Programs

• OPNAVINST 5090.1C , Environmental Readiness Program Manual, Chapter 17: Pesticide Compliance

Ashore

• 42 U.S.C. 4321 et seq., National Environmental Policy Act (NEPA)

• 7 U.S.C. 136 et seq., Federal Insecticide, Fungicide and Rodenticide Act (FIFRA) as amended

• 16 U.S.C. 1531 et seq., Endangered Species Act

• 42 U.S.C. 6901 et seq., Resource Conservation and Recovery Act (RCRA)

• US Air Force Model Pesticide Reduction Plan (July 1996)

ATTACHMENT J-1503020-04

GUIDANCE FOR CONTRACTOR’S WORK PLAN (CWP)

The CWP shall adhere to applicable publications and directives contained in J-1503020-03 (References and Technical Documents. The CWP will require approval by the Contracting Officer (KO). The CWP shall establish the strategy and methods for conducting a safe, effective, and environmentally sound pest management program in compliance with these specifications.

Prospective contractors may review the installation’s historical records of pest activity and abatement actions, survey facilities and grounds, and consult with the Installation IPMC in development of a plan. The CWP shall address continuous monitoring, pest response and removal procedures, record keeping, warranties, education and communication to installation personnel to prevent pests and disease vectors, bird control on applicable airfields and in hangars, etc. The IPM approach should use targeted (i.e., effective, environmentally sound) methods including habitat/facility modification, biological/genetic/cultural control, mechanical/physical control, and where necessary, the judicious use of least hazardous pesticides. The CWP shall include labels, MSDS sheets, and Planned Pesticide Use Sheets and comply with all applicable local, state, and Federal regulations, and the IPMP.

ATTACHMENT J-1503020-05

FREQUENCIES FOR SCHEDULED WORK

• NOTE #1 – Area of each facility is approximated and may vary. Building square footage identifies only the footprint of the facility and does not identify surrounding grounds acreage. Please refer to J-1503050-02: Grounds Maintenance Site Maps for acreage covered under this contract.

Facility Frequency Facility Description Comments MCRTC Brooklyn Monthly Main Building – B#1 MCRTC Brooklyn As Needed (IDIQ) VMF – B#2 MCRTC Brooklyn As Needed (IDIQ) Comm. Building – B#3 MCRTC Newburgh As Needed (IDIQ) Building 200 MCRTC Newburgh As Needed (IDIQ) Building 204 MCRTC Newburgh Monthly Building 271 MCRTC Newburgh Monthly Building 300 MCRTC Newburgh Monthly Building 301 MCRTC Newburgh Monthly Building 302 MCRTC Newburgh As Needed (IDIQ) Building 516 MCRTC Newburgh As Needed (IDIQ) Building 520 MCRTC Newburgh As Needed (IDIQ) Building 706 MCRTC Newburgh As Needed (IDIQ) Building 710 MCRTC Newburgh As Needed (IDIQ) Building 801 MCRTC Newburgh As Needed (IDIQ) Building 807 MCRTC Newburgh As Needed (IDIQ) Building 811 MCRTC Newburgh As Needed (IDIQ) Building 815 MCRTC Newburgh Monthly Building 921 MCRTC Syracuse Monthly Building 2 MCRTC Syracuse Monthly Building 3 MCRTC Syracuse Monthly Building 44

ATTACHMENT J-1503020-06

NUISANCE PEST REQUIREMENTS

Pest

Group Number

Pest Group Name General Requirements

001 Ant Control Prevent and control ants in and around buildings and structures.

003 Cockroach Control Prevent and control all cockroaches.

005 Miscellaneous Arthropod Pest Control Prevent and control nuisance arthropod pests in and around buildings and structures. Includes but is not limited to spiders, silverfish, scorpions, crickets, centipedes, millipedes, box elder bugs, parasitic or biting mites, beetles, etc. (Excludes ants, cockroaches, filth flies, and bees/wasps/hornets covered in separate sections.)

1 After notification 2 After first control action 3 Based on performance assessment (i.e. surveys, customer complaints)

PERFORMANCE STANDARDS

Pest Group

Number

Pest Group Name

Time Period to Respond1

Time Period to Obtain

Control2

Time Period to Maintain Control

Level of Control3 Notes See Below

001 Ant Control 10 days 30 days 365 days 100% control 1, 2, 3, 4

003 Cockroach Control 3 days 7 days 30 days

Retreatment required if:

4 or more adults or nymphs or 1 egg capsule per room

1, 2, 3, 4

Miscellaneous Arthropod Pest

Control 7 days 10 days 30 days

Sensitive areas:100% control Mites: 100% control Retreatment required if:

- Food Handling: 3 or more arthropods/room/survey

- Offices/Admin: 3 or more arthropods/room/survey

- Industrial Areas: 5 or more arthropods/room/survey

- Outdoors: 5 or more arthropods in a 100 square foot area

NOTES:

1 - Regularly scheduled, periodic pesticide applications are not approved for DoD property.

2 - Liquid, dust, or aerosol pesticide formulations shall not be applied indoors when food is exposed or spaces are occupied.

3 - Treatment of areas outside or adjacent areas to the designated area does not constitute an added service call or charge.

4 – Report conditions conducive to pest infestation to the KO and Integrated Pest Management Coordinator within one working day following survey.

ATTACHMENT J-1503020-07

DISEASE VECTOR OR HEALTH PEST REQUIREMENTS

Number

Pest Group Name General Requirements

012 Bee, Wasp, Hornet, and Stinging Arthropod Control

Control stinging arthropod infestations in and around buildings, structures, and areas. Pests include, but are not limited to, bees, wasps, hornets, cicada killers, yellow jackets, and solitary wasps (mud daubers, umbrella wasps).

018 Fire Ant Control Prevent and control fire ants indoors and outdoors.

Sites include all developed and semi-developed areas and other designated sites.

4 After notification 5 After first control action 6 Based on performance assessment (i.e. surveys, customer complaints)

PERFORMANCE STANDARDS

Group

Number Pest Group Name

Time Period to Respond4

Time Period to Obtain

Control5

Time Period to Maintain Control

Level of Control6 Notes See Below

Bee, Wasp, Hornet, and

Stinging Arthropod Control

4 hrs

24 hrs (stinging hazard) 2 days (nest removal)

28 days 100% control 2, 4

Fire Ant Control

Immediate ly

(indoors) 1 day

(outdoors)

1 day (indoors)

5 days (outdoors)

30 days

Indoor: 100% control Outdoors:

- Critical areas: less than 1 mound/colony per acre

- Non-critical areas: less than 3 mounds/colonies per acre

1, 2, 3, 4

NOTES:

1 - Regularly scheduled, periodic pesticide applications are not approved for DoD property.

2 - Liquid, dust, or aerosol pesticide formulations shall not be applied indoors when food is exposed or spaces are occupied.

3 - Treatment of areas outside or adjacent areas to the designated area does not constitute an added service call or charge.

4 – Report conditions conducive to pest infestation to the KO and Integrated Pest Management Coordinator within one working day following survey.

ATTACHMENT J-1503020-08

STRUCTURE DAMAGING PEST REQUIREMENTS

Number

Pest Group Name General Requirements

019 Other Wood Destroying Organisms (Non-Termite) Control

Prevent, manage, and control non-termite wood destroying organisms including, but not limited to powder post beetles (Lyctids and Bostrichids), Anobiids (furniture and deathwatch beetles), old house borer, carpenter ants, and carpenter bees.

020 Survey for Termite and Wood Destroying Organisms

Survey for all termite species and other wood destroying organisms including fungal rots, carpenter ants, and wood boring beetles.

Group

Number Pest Group Name

Time Period to Respond7

Time Period to Obtain Control8

Time Period to Maintain

Control

Level of Control9

Notes See Below

Other Wood Destroying

Organisms (Non- Termite) Control

10 days 30 days 365 days 100% control 1, 2, 5

Survey for Termite and Wood Destroying Organisms

Same day (swarming) 7 days (not swarming)

N/A 2 Working

Days (submit report)

N/A

2, 3, 4 See Pest

Group 019:

Termite and Wood Decay

Inspection Below

NOTES:

1 - Liquid, dust, or aerosol pesticide formulations shall not be applied indoors when food is exposed or spaces are occupied.

2 – Report conditions conducive to pest infestation to the Integrated Pest Management Coordinator within one working day following survey.

3 - Use the Termite and Wood Decay Inspection - DD Form 1070 and submit report to the KO and the IPMC within two working days following survey

4 - Follow Termite Control Specifications (below) for termite management.

5 - If the infestation is a beetle species that will not reinfest seasoned dead wood, treatment shall not be performed.

Provide a report to the IPMC within two working days following survey detailing the species of beetle and the fact that it will not reinfest seasoned dead wood. This should refer to parasitic or biting mites only, e.g. bird mites, chiggers.

7 After notification 8 After first control action 9 Based on performance assessment (i.e. surveys, customer complaints)

TERMITE AND WOOD DECAY INSPECTION

(DD Form 1070) (Use with Pest Group Sheet 019)

DATE

INSPECTED

BUILDING

NUMBER

INSTALLATION TYPE

BUILDING

INSPECTOR

PERM

TEMP

I. FAVORABLE TERMITE AND FUNGI INFESTATION CONDITIONS

WOOD IN CONTACT WITH SOIL POOR VENTII ATION UNDER BUILDING

FORM BOARDS LEFT IN CONCRETE WATER COLLECTIONS UNDER BUILDING

WOOD MEMBERS SET IN CONCRETE FLOOR VINES AND SHRUBS AGAINST BUILDING

WOOD STEPS IN CONTACT WITH SOIL LEAKY PLUMBING IN PUTTING

WOOD STEPS WITHOUT SHIELDS WOOD SCRAP PILED TINDER BUILDING

WOOD SIDING IN CONTAI.T WITH SOIL LOOSE WIRE IN CONTACT WHH SOIL

PIPES IN CONTACT WITH SOIL AND WOOD OTHER (Specify)

NO SHIELDS ON FOUNDATION

FAULTY TERMITE SHIELD

II. LOCATION OF INFESTATIONS

FOUNDATION TIMBERS BASEBOARDS

WOOD PILLARS DOOR FRAMES

SILLS WINDOW FRAMES

CROSS BEAMS STEPS

FURNITURE ROOF

FLOOR JOIST OTHER (Specify)

FLOOR

STUDS

III. TYPE OF TERMITE

IV. TYPE OF FUNGI V. DAMAGE

SUBTER-

RANEAN

NONSUB

TER

RANEAN

WOOD

DECAY

W000

STAINING

STRUCT

URAL

WEAKEN

ING

SUPERFICIA

L

ESTIMATED

COST

VI. REPAIR AND TREATMENT

TYPE RECM ACCO

MP

TYPE

REC

M

ACCO

MP

REMOVAL OF WOOD FROM SOIL

CONTACT

REPAIR OF TERMITE SHIELDS

SEALING CRACKS IN CONCRETE REMOVAL OF CONCRETE FORMS

POINTING UP POOR MORTAR REMOVAL OF VINES AND SHRUBS

LOWERING GRADE LEVEL REMOVAL OF WOOD TRASH

CAPPING CONCRETE FOUNDATION OTHER (Specify)

IMPROVING DRAINAGE UNDER

IMPROVING VENTILATION UNDER

VII. CHEMICAL CONTROL

APPLICATION OF POISON DUST TO SHELTER TUBES

YES NO

CHEMICAL USED

SOIL POISON

YES NO

TRENCH

DEPTH

LINEAR FEET CHEMICAL USED

REPLACEMENT OF

DAMAGED WOOD

YES NO

NO. OF M BD

FELT REPLACED

UNTREATED DIPPED SOAKED SPRAYED PRESSURE

TREATED

DRILLING AND FLOODING TREATMENTS YES

NO

CHEMICAL USED

WOOD INJECTION FOR DRY WOOD TERMITE YES

NO

CHEMICAL USED

VIII. COST

LABOR MATERIAL OTHER TOTAL

IX. TREATMENT EFFECTIVENESS

DATE REMARKS INSPECTOR

DATE REMARKS INSPECTOR

DATE REMARKS INSPECTOR

DATE TITLE OF INDIVIDUAL AFFECTING

REPAIR AND TREATMENT

SIGNATURE

ATTACHMENT J-1503020-09

LAWN, TURF AND ORNAMENTAL PLANT PEST CONTROL

Pest Group Number Pest Group Name General Requirements

021 Mole Cricket Control Control mole crickets in lawns.

022 Turf and Ornamental Pest Control Control arthropod pests in turf and on ornamental plantings.

Group Number

Pest Group Name

Time Period to

Respond10

Time Period to Obtain Control11

Time Period to Maintain Control

Level of Control12 Notes See Below

Mole Cricket Control

7 days 7 days 60 days

2 mole crickets or less/4 ft2 Retreatment, if required, shall be performed at one-week intervals until the required Level of Control is established

2, 3

Turf and Ornamental Pest Control

5 days 7 days 60 days

No turf pests after 1 week Retreatment required if:

- 3 or more leaf feeding arthropods on 20 leaves surveyed, OR

- 3 or more scale insects on 5 tree branches surveyed, OR

OR

- Defoliation of 10% or more of the plant compared to a previous observed status, OR

1, 3, 4

NOTES:

1 – Report conditions conducive to pest infestation to the Integrated Pest Management Coordinator within one working day following survey.

2 - The Contractor may provide irrigation if required at no additional cost. Water for irrigation may be made available for the Contractor's use at fire hydrants located throughout the activity area; however, the KO should be contacted prior to their use.

3 - Post/Notify as required by applicable state/local regulations.

4 - Misapplication to target areas, or drift, runoff or other off-target effects that kill or damage any vegetation shall result in the Contractor replacing that vegetation at no charge to the Government.

10 After notification 11 After first control action 12 Based on performance assessment (i.e. surveys, customer complaints)

ATTACHMENT J-1503020-10

VEGETATION MANAGEMENT REQUIREMENTS

Number

Pest Group Name General Requirements

024 Industrial, Sidewalk, Substation, Vault, and Right-Of-Way Weed Control

Provide bare ground weed control in cracks in sidewalks and paved surfaces, at fence line locations, in transformer vaults, around fire hydrants, and other designated locations.

025 Turf and Ornamental Bed Weed Control

Control weeds in turf areas and in ornamental plant beds.

Group Number

Pest Group Name

Time Period to Respond

Time Period to Obtain

Control14

Time Period to Maintain Control

Level of Control15 Notes See Below

Industrial, Sidewalk, Substation, Vault, and Right-Of-Way Weed Control

5 days 14 days Season long

Maintained with only minor occurrences of weeds in cracks and paved areas. Appearance is determined by PCPAR.

Turf and Ornamental Bed Weed Control

7 days 21 days Season long

More than 4 weed plants per ornamental bed or 1600 ft2 of turf are grounds for retreatment of that area at the Contractor’s expense.

1, 2, 3

1 – Report conditions conducive to pest infestation to the KO and Integrated Pest Management Coordinator within one working day following survey.

2 - Post/Notify as required by applicable state/local regulations.

3 - Misapplication to target areas, or drift, runoff or other off-target effects that kill or damage any vegetation shall result in the Contractor replacing that vegetation at no charge to the Government.

4 - Permits may be required to perform this work (i.e., NPDES permit, FWS permit). The contractor shall obtain all permits and provide a copy to the KO prior to commencing control.

13 After notification 14 After first control action 15 Based on performance assessment (i.e. surveys, customer complaints)

ATTACHMENT J-1503020-11

VERTEBRATE PEST REQUIREMENTS

Number

Pest Group Name General Requirements

027 Commensal Rodents In and Around Buildings and Structures

Prevent and control rodents indoors or within 75 linear feet of the exterior walls of designated buildings and structures.

Rodent pests include, but are not limited to Norway rats, roof rats, house mice, field mice, groundhogs (woodchucks) and other marmots. Service requires removal of dead animals.

029 Pest Vertebrate Control Control pest vertebrate animals including, but not limited to, feral dogs and cats, squirrels, groundhogs, skunks, snakes, opossums, raccoons, and mongoose. Comply with local laws and regulations.

16 After notification 17 After first control action 18 Based on performance assessment (i.e. surveys, customer complaints)

PERFORMANCE STANDARDS

Pest Group Number

Pest Group Name

Time Period to

Respond16

Time Period to Obtain Control17

Time Period to Maintain Control

Level of Control18 Notes See Below

027 Commensal Rodents

1 day (indoors)

3 days (outdoors)

10 days (indoors) 30 days

(outdoors)

30 days

100% control Retreatment required if rodent signs are identified after treatment

1, 2, 3, 4

029 Pest Vertebrate Control

24 hr, Immediately (emergency, indoors

3 days, 24 hr

(emergency, indoors)

N/A 100% control 2, 4, 7, 8, 9, 10, 11

ATTACHMENT J-1503020-11

VERTEBRATE PEST REQUIREMENTS (cont'd)

1 - Regularly scheduled, periodic pesticide applications are not approved for DoD property.

2 – Report conditions conducive to pest infestation to the KO and Integrated Pest Management Coordinator within one working day following survey.

3 - Caught rodents shall not be left in traps for longer than 24 hours. Rodenticides should not be used in day care centers, schools or areas where food is prepared or served without special approval from the KO and notification of the Preventive Medicine Department

4 - Carcass disposal, transportation, disposition, deodorizing etc. are considered a normal part of pest control and are at no additional cost to the government.

5 - Permits may be required to perform this work (i.e., NPDES permit, FWS permit). The contractor shall obtain all permits and provide a copy to the KO prior to commencing control.

6 - Only three species of birds (European starling, English sparrow, and pigeons) may be controlled without a permit from the US Fish and Wildlife Service. Use of ultrasonic, electromagnetic, sonic repellant devices or electric shock devices is prohibited.

7 - Feral Cats: Captured feral cats may be taken to the local humane society or animal shelter. Feral cats and other animals shall not be neutered and released onto the installation.

8 - Wild Vertebrates That Do Not Transmit Rabies: Captured animals may be transported to remote areas of the Station and release or release in-area after exclusion is performed, if allowed by state laws. Animals classified as nuisance animals should be humanely euthanized. Relocation and release of captured animals must be done in accordance with all Federal, State, and local regulations. If transport/release is not possible or practical the animal may be euthanized humanely and the carcass disposed of in accordance with county/local laws.

9 - Leg hold traps or other devices that will harm animals are prohibited. Traps shall be placed and set in such a way as to prevent harm to humans and minimize harm to non-target animals.

10 - Non-lethal control is required unless the animal appears rabid, sick, is extremely aggressive and poses a danger to the contractor during trapping, poses a danger to personnel or is a nuisance animal. Captured animals shall be scrutinized for sickness. If sickness is suspected, or animals are defined as nuisance species, they shall be humanely euthanized. Coordinate with Base Medical Department for carcass disposition (disposal or transport as applicable). If animals appear healthy, transport/release if possible, or dispose of at the discretion of the KO. Relocation and release of captured animals must be done in accordance with all Federal, State, and local regulations. Animals defined as nuisance animals should be humanely euthanized rather than relocated and released

11 - Lethal control is prohibited without direct consent of the KO. If permitted, firearms use shall always be coordinated with Base Security.

ATTACHMENT J-1503020-12

TERMITE CONTROL SPECIFICATIONS

Unscheduled Structural Pest Control Services. The Contractor shall provide structural pest control services on an unscheduled (indefinite quantity) basis as specified below. Services shall be completed within 10 working days after receipt of the task order. At the time of any soil treatment application, the soil shall be in a condition with low moisture to allow uniform distribution of the treatment solution throughout the soil. The Contractor shall not apply pesticide during or immediately following heavy rains, or when conditions will cause runoff and create an environmental hazard. No pesticides shall be applied to the soil beneath a plenum air space. Pesticides shall not be applied until the approximate location of water and sewer lines are known.

(1) Subterranean Termite Control. All termite infestations in the structure shall be controlled within 30 days of treatment.

Toxicants shall be delivered to the project site in sealed and labeled containers as supplied by the manufacturer or formulator. Labels shall bear the manufacturer's warnings to be observed in handling and use of material, and bear evidence or registration under the FIFRA.

(a). MATERIALS. "The termiticide used for control of subterranean termites shall be a soil applied nonrepellent termiticide (such as fripronil, imidacloprid or chlorfenapyr). If needed, remedial treatments can be applied to wooden structural members using a borate product containing the active ingredient disodium octaborate tetrahydrate (i.e. Tim-BorTM, Bora-CareTM ). The termiticide product shall be applied at the highest labeled rates and concentrations."

1. Delivery and Storage. Termiticide shall be delivered to the project site in sealed and labeled containers as supplied by the manufacturer or formulator. Labels shall bear manufacturer's warnings to be observed in handling and use of the material. Labels shall bear evidence of registration under the Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA) as amended by the Federal Environmental Pesticide Control Act (FEPCA) of 1972.

2. Samples. The Contractor shall submit on request, or the Contracting Officer may draw at any time, without prior notice, from stocks at the site of the work, samples of insecticide concentrates and diluted insecticide solutions or emulsions being used or presumed to be for use in this work.

Should analysis indicate such samples to contain less than the amount of active ingredient claimed on the label or specified herein, then all work done with such insecticides shall be repeated using insecticides conforming to this specification without additional cost to the Government.

(b). APPLICATION SHALL BE MADE IN THE FOLLOWING MANNER:

1. Interior Areas to be Treated. Expansion or construction joints located under and adjacent to interior and exterior walls shall be treated by drilling holes through the floor slab and injecting the proper insecticide. Drill holes should be spaced in a manner that will allow for application of a continuous chemical treatment zone (i.e. holes approximately 3/8 inch in diameter and no more than 12 inches apart, on center, not more than 6 inches from the wall being treated). Termiticide shall be applied into these holes under pressure at a rate as specified on the insecticide label. Plumbing chases shall also be treated.

TERMITE CONTROL SPECIFICATIONS (cont'd)

2. Exterior Areas to be Treated. Soil adjacent to the outside of wall shall be treated. The treatment shall extend from the top of the footing to the top of the soil to form a vertical insecticide barrier along the building at the rate of not less than four gallons per ten linear feet per foot of depth. Backfill shall be tamped and sufficient in quantity to provide a surface sloping away from the structure. Voids in concrete block walls, and between brick veneer and foundation walls shall be treated by drilling and injecting insecticide as specified on the label.

3. Label Requirements. Rates and methods of application shall be in strict accordance with the printed instructions on the manufacturer's insecticide label with the insecticide applied at the highest labeled rate and concentration. Conflicts between this specification and label directions shall be resolved in favor of the label. Prior to performing the work, the termiticide label, labeling and Material Safety Data Sheet (MSDS) must be submitted to the Contracting Officer for approval.

(c). DRILL HOLES

1. Drill holes in masonry walls shall be plugged neatly and solid using 1.2 sand cement motor.

2. Drill holes in floor slabs shall be plugged neatly and solid using an approved non-shrink grout.

3. Drill holes in expansion joints shall be sealed with an approved mastic cement. Excess mastic shall be removed and left neat.

(d). EXISTING UTILITIES. The Contractor shall determine in advance of commencing work the locations of water lines, drain lines, fuel oil lines and heating ducts, and shall avoid damage to these lines and ducts during drilling and rodding operations. Any damage caused by the Contractor's operations, if not conducted according to the information obtained from the Contracting Officer, shall be immediately repaired at the Contractor's expense.

(e). SITE PROTECTION AND BACKFILL TREATMENT. All shrubbery shall be protected from damage during all operations under this contract. Any such damage incurred shall be immediately corrected at no cost to the Government. Where grass is removed from trenching or excavated material, after backfilling, the sod shall be replaced and thoroughly dampened with the approved termiticide solution if allowed by the insecticide label.

(f). CERTIFICATION OF WORK. Upon final completion of the soil treatment, and as a condition for final acceptance, the Contractor shall furnish a written certificate stating:

1. Insecticide used had required concentration, brand name, and manufacturer thereof.

2. Rate and method of application complied in every respect with the standards contained herein.

(g). WARRANTY. The Contractor shall provide the Contracting Officer with a written warranty, in acceptable form, for each building or building unit treated for subterranean termites. The warranty shall be prepaid (to be included in the total price of the treatment) good for a period of no less than five years, guaranteeing retreatment of any subsequent infestation and further that any structural damage due to an infestation after the initial treatment shall be repaired at no additional cost. A detailed written structural assessment shall be made by the Contractor with concurrence by the Contracting Officer prior to initial treatment for reference at a later date, should there be any questions of subsequent damage. The limit of the Contractor's liability for repairs is $25,000 per building.

(2) Drywood Termite Control. Provide drywood termite control as described below.

The presence of an inspector trained in fumigation is essential while fumigant concentration readings are taken to determine that all drywood termites are killed during fumigation. Adherence to proper procedures must be assured while the work is being accomplished.

(a) Safety Measures. The Contractor shall ensure proper techniques and procedures are followed.

Precautions shall be taken to prevent injury to any person and damage to property as a result of work accomplished under this section. These precautions shall include, but are not limited to, the following:

1. Safety Equipment. Before releasing any gas, the Contractor shall deliver to the KO, ready for use by Government personnel, two full-face gas masks, each with two new, unused canisters appropriate for the gas to be employed, or a similar number of self-contained breathing apparatuses, each with a cylinder of air; a completely stocked and illustrated fumigator's first aid kit (all meeting specifications of the Health and Safety Division, Bureau of Mines, U.S. Department of the Interior);

and at least one approved low-volume gas detector for the fumigant to be employed. All such equipment will be held at the site until completion of the work.

2. Notification of Security Officer. The activity Security Officer shall be notified at least 24 hours prior to the commencement of fumigation operations, and upon completion of the work that the building is being left unattended.

3. Disconnection of Services. Prior to fumigation, all gas and other fuel supplies shall be cut off. Electric and telephone service need not be disconnected; however, the electric main entrance switch shall be pulled. All fires, including pilot lights, shall be extinguished prior to beginning fumigation procedures. After fumigation and subsequent ventilation has been completed, electric power, pilot lights, etc., shall be turned on or relit. Damage to any service caused by the Contractor shall be repaired at no additional cost to the Government.

4. Barricades. A double rope barricade shall be placed no closer than 20 feet to, and around the entire perimeter of the building to be fumigated. Existing fences may substitute for rope barricades if they are at least 20 feet from the building.

5. Signs. Warning signs shall be placed prominently on all means of ingress to the building and grounds, including fences and rope barricades surrounding the work. Signs shall include a statement that the building is being fumigated with “sulfuryl fluoride” or the name of another fumigant gases. Signs shall not be less than 18 by 24 inches in size and shall meet all state and local wording requirements.

6. Guards. At least two guards shall be placed around the building before gas is released.

Guards shall be positioned at either end of the structure so the maximum amount of the building is under continuous observation. Guards, warning signs, and barricades shall be maintained during the entire fumigation process until the Contractor has checked for gas concentration and declares the entire area gas free and safe for normal occupancy.

7. Lighting. The Contractor shall provide adequate lighting around the exterior of the structure being fumigated to permit ready detection of trespassers during the night.

8. Evacuation of Personnel. After all persons and animals are evacuated from within and under the building, guards are posted, and prior to release of the fumigant, the Contractor and KO shall jointly inspect all rooms and spaces to assure evacuation is complete.

9. Partial Fumigation. No partial fumigation of any building shall be allowed.

(b) Preparation.

1. Grass and Shrubbery. Wet the soil in planted areas to a depth of six inches for a distance of one foot outward from the areas to be covered by the tarp, to protect nearby plant roots from injury.

In this respect, the Contractor shall exercise every precaution to protect and preserve grass and shrubbery that may come into contact with the building. Any plants, shrubs, or grass damaged by the gas or otherwise, shall be replaced at no additional cost to the Government.

2. Sampling. Furnish and install a minimum of four polyethylene tubes leading from approved locations within the structure to an approved location outside for the purpose of recording gas concentrations. Also furnish for use and have available during the entire fumigation period an approved thermal conductivity gas metering device, correctly calibrated in ounces per 1,000 cubic feet for the fumigant to be employed, and capable of sampling from the polyethylene tubes.

3. Removal of Damageable Items. Remove all items from the building that might be damaged by the fumigant and maintain in locked storage. Lost or damaged items shall be repaired or replaced by the Contractor at no additional cost to the Government.

4. Building Proper. In preparing the building for fumigation, exterior doors and windows and all entrances to enclosed interior areas, such as doors or windows leading to closets or cabinets or between rooms, shall be opened to facilitate distribution of the gas during fumigation and insure maximum ventilation at the end of the fumigation period.

(c) Procedure.

1. General. The building to be fumigated shall be completely enclosed with a gas-impervious tarpaulin material, with all sheeting seams securely sealed, and the lower edges of the enveloping cover sealed to the ground or finish grade level in a trench, with moist soil or with sand/water snakes (flexible tubing filled with water).

2. Introduction of Chloropicrin. After preparation and sealing of the structure (except for one entrance) and prior to injection of the sulfuryl fluoride (Vikane), the Contractor shall introduce chloropicrin into the structure. The chloropicrin shall be introduced by placing cotton in shallow dishes, setting the dishes in the air stream of an electric fan within the structure, and pouring the chloropicrin over the cotton at the rate of one ounce per 10,000 to 15,000 cubic feet of space to be fumigated. The building will then be sealed and the fans started.

3. Fumigation. After introduction of the chloropicrin, the fumigant described below shall be released from cylinders placed outside the enclosed areas through not less than two hoses of either rubber, polyethylene tubing, or copper tubing leading to points well distributed within each floor of the building as previously approved by the KO. The liquid shall be injected at a temperature and pressure to guarantee complete vaporization upon its release. Sufficient air turbulence shall be created to maintain uniform distribution of the fumigants throughout all portions of the building and to prevent stratification of gas at any location by use of not less than four electric fans, each having a capacity of 3,000 to 5,000 cubic feet per minute (CFM).

4. Fumigant and Dosage Rates. The fumigant shall be sulfuryl fluoride (Vikane) gas, injected in vapor form, and maintained in accordance with Dow Chemical Company Fumiguides B and Y.

When the whole Fumiguide calculated initial concentration is obtained from all sampling points, the 24-hour fumigation time period starts. If the Contractor wishes to increase dosage rates to shorten the fumigation time in accordance with Fumiguide Y, prior approval of the KO and the NAVFAC PPMC is required.

5. Borate Treatment. In addition to the aforementioned treatment, a glycol borate solution of Bora-CareTM shall be applied in attic and crawl spaces of the building. Apply a one-part water to one-part Bora-CareTM solution to the point of run off (one gallon of diluted solution for each 500 feet of surface area) to all exposed wood surfaces. Follow all labeled directions for the safe handling and use of this product. Aerosol application will be allowed only in inaccessible areas and with the prior approval of the KO.

6. Sampling. During the actual 24-hour fumigation period, the gas-laden atmosphere within the enveloped structure shall be sampled from each sampling point five times: at the inception, and at four, eight, 16, and 24 hours after inception. The Contractor shall take appropriate action to ensure proper distribution of the gas and maintenance of the level of concentration specified.

Sample readings shall be recorded and a copy of the readings provided to the KO upon completion of the treatment.

(d) Aeration. Upon termination of the fumigation exposure period, the Contractor shall remove all seals, open all doors and windows, and use ventilation fans to remove fumigants from dead air pockets with full observance of accepted safety, state, and labeled aeration procedures to avoid exposure of any persons or other life to dangerous concentrations of fumigant gas. The Contractor shall check for complete aeration with a low-volume gas detector in all enclosures, which might retain concentrations of gas, such as closets, cabinets, refrigerators, and chests, and certify to the KO that the structure is gas free and available for occupancy.

(e) Clean Up. Upon completion of the fumigation, remove all debris and rubbish resulting from the work, replace damageable items removed from the building, and repair all damage resulting from the work.

(f) Warranty. The Contractor shall guarantee the fumigated building is completely free of living drywood termites for one year after the fumigation is completed. The Contractor, accompanied by the KO, shall make two thorough inspections of the structure, at six-month intervals, following the fumigation date.

The written findings of each inspection shall be provided to the KO within 10 working days after inspection completion. Positive evidence of drywood termite infestation, except from furniture and other moveable property installed during the one-year period, shall constitute conclusive evidence of improper fumigation and lack of control, and the building shall be refumigated at no additional cost to the Government.

ATTACHMENT J-1503020-13

PEST MANAGEMENT OPERATIONS REPORT

New Pesticide Management Record (SAMPLE) Directions:

1. Select the installation and fill in the Office/Contractor, if applicable

2. Fill in a separate form for each pest management operation. For pesticide applications, the pounds of active ingredient (PAI) will be calculated automatically based on the data you enter.

Installation Name:

Department/Company:

Office/Contractor:

(optional)

Negative Report

Contract or In-House: 5/17/2012 6:23:1

Application Date:

Inside or Outside:

Facility: Building # or Area

Operation:

Site:

Save Defaults*

Clear Defaults

Pest:

Applicator Name: Create Applicator List

Pesticide Trade Name: - Select an installation to see the pesticide list

Pesticide Active Ingredient:

EPA Registration # or Other #:

Formulation:

Area Treated:

Quantity of Final Product Applied:

Final Concentration (%):

PAI*: Will be automatically calculated for the appropriate Operations*

Comments:

Additional Comments (Optional):

* Whatever is currently in the following fields will now be the default entry when the page is opened: Contract or In-

House; Application Date; Inside or Outside; Operation; Site. New: If you want the current date to continue to load while the other default values are loaded, save the Application Date as a blank.

Submit Record

Delete Record

J-1503030-01

REFUSE INVENTORY & FREQUENCIES

Location Dumpster Size Dumpster Type Quantity Disposal Frequency MCRTC Brooklyn 8 - CY General Waste 3 Weekly MCRTC Brooklyn 8 - CY Recycling 1 Weekly MCRTC Brooklyn 30-CY Roll-off 1 Monthly (For Drill Weekends) MCRTC Syracuse 8 - CY General Waste 2 Twice per Month MCRTC Syracuse 20-CY Roll-off 1 Monthly (For Drill Weekends) MCRTC Red Bank 8 – CY General Waste 1 Weekly MCRTC Red Bank 8 – CY Recycling 1 Weekly

J-1503050-01

GROUNDS MAINTENANCE & SNOW REMOVAL SITE MAPS

Grounds Maintenance Site Map

Snow Removal Site Map

J-1503050-02

GROUNDS ACREAGE SCHEDULE

Facility COL Acreage Plant Beds (SF) Trees Notes:

MCRTC Brooklyn (Main Building) 1 7.4 1,200 15 N/A MCRTC Brooklyn (Baseball Field) 2 3.74 0 0 Include adjacent parking lot MCRTC Newburgh (Ft. Stewart) 1 4.50 2,500 25 N/A

MCRTC Newburgh (Enclave) 1 5.12 1,400 18 N/A MCRTC Syracuse 1 8.55 0 40 N/A MCRTC Red Bank 1 1.66 600 21 N/A

J-1503050-03

COMMON OUTPUT LEVEL CHART

COMMON OUTPUT LEVEL STANDARDS

(COLS) CHART

Improved Area Work Includes

SPEC

ITEM

TASK COL1

COL 1 COL 2

3.1.1.1 MOWING AND TRIMMING Yes Yes

3.1.1.2 EDGING Yes No

3.1.2 VEGETATION CONTROL Yes No

3.1.3 DEBRIS REMOVAL Yes Yes

3.1.4 SHRUB AND HEDGE

MAINTENANCE

Yes No

3.1…