Drawings.pdf
PDF 9 MB Posted
- Solicitation number
- N4008313R0032
About this file
Drawings
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
E N
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
DOD LOCK PROGRAM RDT&E PROJECT SUPPORT
SMART MAGAZINE MODIFICATIONS
DRAWING INDEX
D W
G N
O
S E
Q U
E N
C E
D W
G T
IT
LE
R E
V
IS
IO
N
N U
M B
E R
GENERAL
STRUCTURAL
GENERAL NOTES
FOOTING & FOUNDATION AND ROOF PLANS
FRONT ELEVATION
WALL SECTION
WALL SECTION
CONCRETE ARCH MAGAZINE
ELECTRICAL
DEMOLITION ELEVATIONS AND PLAN
DOOR ELEVATION, NOTES AND SCHEDULES
DOOR ELEVATION AND DETAILS
DOOR PANEL ELEVATIONS
DOOR ELEVATIONS AND DETAILS
DOOR ELEVATION AND STIFFENER DETAILS
DETAILS
PADEYE ATTACHMENT DETAILS
DOOR ELEVATION AND DETAILS
CANOPY PLAN AND SECTIONS
STRUCTURAL DEMOLITION
WALL SECTION
WALL SECTION
G-001 01 PROJECT COVER SHEET
S-001 S-D01
S-101
S-201
S-301
S-302
S-303
S-304
S-305
S-501
S-502
S-701
S-702
S-703
S-704
S-705
S-706
S-707
E-D01
DETAILSS-307
WALL SECTION
GROUND PLAN AND ELEVATIONSE-102
ELECTRICAL DETAILS AND PANEL SCHEDULEE-103
E-104 ELECTRICAL DETAILS
S-306
WALL SECTION
SITE
SITE PLANC-001 02
VICINITY MAP
VENT OPENING DETAILSS-504
CANOPY DETAILSS-503
ELECTRICAL ABBREVIATIONSE-001 26
FLOOR PLAN - LIGHTING/POWERE-101 28
D W
G N
O
S E
Q U
E N
C E
D W
G T
IT
LE
R E
V
IS
IO
N
N U
M B
E R
WELDMENTS
W-101 DOOR AND LOCK PILASTER INSERTS
W-102
DOOR AND LOCK PILASTER INSERTS
W-103
DOOR AND LOCK PILASTER INSERTS
W-105
DOOR AND LOCK INSTALLATION NOTES
W-201 HORIZONTAL PILASTER WELDMENT
W-202
HORIZONTAL PILASTER WELDMENT
W-203
HORIZONTAL PILASTER WELDMENT
W-204
HORIZONTAL PILASTER WELDMENT
W-301
VERTICAL PILASTER WELDMENT
W-302
VERTICAL PILASTER WELDMENT
W-303
VERTICAL PILASTER WELDMENT
W-304
VERTICAL PILASTER WELDMENT
W-305
VERTICAL PILASTER WELDMENT
W-306
BAR, VERTICAL PILASTER WELDMENT
W-401
DRIVE-THRU TRENCH SUBASSEMBLY
W-402
DOOR TRENCH WELDMENT, DRIVE-THRU
W-403
DOOR TRENCH WELDMENT, DRIVE-THRU
W-404
DOOR TRENCH WELDMENT, DRIVE-THRU
W-405
DOOR TRENCH WELDMENT, DRIVE-THRU
W-406
TRENCH COVER WELDMENT, DRIVE-THRU
W-407
TRENCH COVER WELDMENT, DRIVE-THRU
W-408
TRENCH COVER WELDMENT, DRIVE-THRU
W-409
LINK, TRENCH COVER
W-410
HINGE PIN, TRENCH COVER
W-501
NON DRIVE-THRU TRENCH SUBASSEMBLY
W-502
DOOR TRENCH WELDMENT, NON DRIVE-THRU
W-503
DOOR TRENCH WELDMENT, NON DRIVE-THRU
W-504
DOOR TRENCH WELDMENT, NON DRIVE-THRU
W-505
DOOR TRENCH WELDMENT, NON DRIVE-THRU
W-506
TRENCH COVER WELDMENT, NON DRIVE-THRU
W-507
TRENCH COVER WELDMENT, NON DRIVE-THRU
W-601
TAPERED DOOR GUIDE
W-603
RECEIVER, LOCKING T BOLT
PADEYE DETAILSS-708 25
W-307 CORING HOLE TUBE WELDMENT
W-602 DOOR BUMP STOP
W-104 DOOR AND LOCK PILASTER INSERTS35
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
717713
0 72
7 2
2 72
748749750 747
MSA SECURITY ROAD
SITE NOTES:
LEGEND:
APPROXIMATE
CONSTRUCTION AREA LIMITS
MSA
RESTRICTED
AREA
(U N
P A
V E
D R
O A
D
BASE CONTRACTOR
ACCESS GATE
PROJECT MAGAZINE
BUILDING 710
MSA
ACCESS GATE
MSA
ACCESS GATE
CONTRACTOR TRAILER
& LAYDOWN AREA
CONTRACTOR RESPONSIBLE
FOR MAINTAINING PRESENT
CONDITION OF UNPAVED ROAD
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
GENERAL:
1. ALL DETAILS, SECTIONS, AND NOTES SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL
AND SHALL APPLY TO SIMILAR SITUATIONS ELSEWHERE UNLESS NOTED OR SHOWN OTHERWISE.
NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER THESE GENERAL NOTES.
GENERAL NOTES SHALL TAKE PRECEDENCE OVER THE SPECIFICATIONS.
2. REFER TO THE SPECIFICATIONS FOR INFORMATION NOT COVERED BY THESE GENERAL NOTES OR
THE STRUCTURAL DRAWINGS.
3. ALL CONSTRUCTION AND INSPECTION SHALL BE IN ACCORDANCE WITH UFC 1-200-01
(16 AUGUST 2010), UFC 3-301-01 (20 JULY 2010) AND 2009 EDITION OF THE INTERNATIONAL BUILDING CODE (IBC). THE CONTRACTOR SHALL COORDINATE ALL REQUIRED INSPECTIONS AND SHALL NOT
PROCEED WITH THE WORK INVOLVED UNTIL THE INSPECTIONS HAVE BEEN DONE.
4. THE CONTRACTOR SHALL ALLOW FOR OBSERVATION VISITS BY CONTRACTING OFFICER'S
REPRESENTATIVE AT KEY CONSTRUCTION MILESTONES.
5. THE CONTRACTOR MUST SUBMIT A WRITTEN REQUEST FOR, AND OBTAIN THE CONTRACTING
OFFICER'S REPRESENTATIVE WRITTEN PRIOR APPROVAL FOR ALL CHANGES, MODIFICATIONS,
AND/OR SUBSTITUTIONS.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY AND PROTECTION IN AND AROUND THE
JOB SITE AND/OR ADJACENT PROPERTIES.
7. THE CONTRACTOR SHALL PROVIDE ADEQUATE TEMPORARY BRACING FOR ALL PORTIONS OF THE
BUILDING AND DOORS UNTIL THE ENTIRE REMODEL OF THE STRUCTURE IS COMPLETE.
8. IF EXISTING CONDITIONS AT THE SITE ARE NOT AS SHOWN ON THE DRAWINGS, THE CONTRACTING
OFFICER'S REPRESENTATIVE SHALL BE NOTIFIED IMMEDIATELY. CHANGES MAY OCCUR DUE TO
SUCH VARIATIONS IN EXISTING CONDITIONS.
9. ALL EQUIPMENT ANCHOR BOLT SIZES AND LOCATIONS SHALL BE VERIFIED IN THE FIELD WITH THE DOOR MANUFACTURER'S CERTIFIED DRAWINGS, LATEST REVISION, BEFORE PLACING CONCRETE.
10. NO PENETRATIONS SHALL BE ALLOWED THROUGH ANY CONCRETE BEAMS, COLUMNS, PIERS, OR
JAMBS, WITHOUT THE STRUCTURAL ENGINEER'S WRITTEN APPROVAL. MECHANICAL AND/OR
OTHER PENETRATIONS SHALL BE RE-ROUTED AS REQUIRED AT THESE LOCATIONS.
11. ALL PENETRATIONS THROUGH ANY CONCRETE WALLS SHALL BE BUILT INTO THE WALL AS THE
WALL IS BEING CONSTRUCTED AND SHALL BE REVIEWED BY THE CONTRACTING OFFICER'S
REPRESENTATIVE PRIOR TO INSTALLATION.
12. THE CONTRACTOR SHALL COORDINATE ALL WORK BETWEEN THE VARIOUS TRADES. ALL
OMISSIONS AND/OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS
AND/OR THE SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTING
OFFICER'S REPRESENTATIVE BEFORE PROCEEDING WITH ANY WORK INVOLVED.
FOUNDATION NOTES:
1. THE FOUNDATION DESIGN HAS BEEN PREPARED BASED ON A GEOTECHNICAL REPORT PREPARED
BY MIDWEST TESTING LABORATORY, DATED JANUARY 17, 2013 AND THE FOLLOWING CRITERIA.
2. THE FOUNDATIONS SHALL BE DESIGNED USING THE FOLLOWING ALLOWABLE BEARING
PRESSURES:
DEAD PLUS LIVE LOAD................................................................. 3,000 PSF
TOTAL DESIGN LOAD (INCLUDING WIND OR SEISMIC)............ 4,000 PSF
3. FOOTINGS SHALL HAVE A MINIMUM BOTTOM DEPTH OF 3 FEET BELOW ADJACENT GRADE.
4. ALL FILLING, BACKFILLING AND COMPACTING SHALL BE PER GEOTECHNICAL REPORT.
5. CONTRACTOR TO PROVIDE FOR DE-WATERING OF EXCAVATIONS FROM EITHER SURFACE, WATER, GROUND WATER OR SEEPAGE.
6. CONTRACTOR SHALL PROVIDE FOR DESIGN AND INSTALLATION OF ALL CRIBBING, SHEATHING, AND SHORING REQUIRED TO SAFELY RETAIN THE EARTH BANKS.
7. EXCAVATION FOR FOUNDATIONS SHALL BE APPROVED BY THE CONTRACTING OFFICER'S
REPRESENTATIVE PRIOR TO PLACING THE REINFORCING AND CONCRETE.
8. SHALLOW FOOTING FOUNDATIONS SHALL BE PLACED AND INSTALLED IN ACCORDANCE WITH THE
CONSTRUCTION DRAWINGS. SPECIFICATIONS, AND GEOTECHNICAL REPORT PREPARED FOR THE
PROJECT.
9. FOUNDATION BACKFILL AND UTILITY TRENCH BACKFILL WITHIN BUILDING AREA SHALL BE
MECHANICALLY COMPACTED IN LAYERS TO THE APPROVAL OF THE CONTRACTING OFFICER'S
REPRESENTATIVE. FLOODING WILL NOT BE PERMITTED.
SPECIAL INSPECTIONS:
1. THE CONTRACTOR SHALL RETAIN QUALIFIED SPECIAL INSPECTORS TO INSPECT THE FOLLOWING
WORK. THE WORK AND REPORTS OF THE SPECIAL INSPECTOR OR INSPECTORS SHALL MEET THE
REQUIREMENTS OF INTERNATIONAL BUILDING CODE CHAPTER 17.
a) SOILS
b) CONCRETE AND REINFORCING STEEL
c) INSTALLATION OF ANCHORS IN EXISTING AND NEW CONCRETE
d) STRUCTURAL STEEL, INCLUDING WELDING AND HIGH STRENGTH BOLTING
CONCRETE:
1. ALL REINFORCED CONCRETE SHALL COMPLY WITH ACI 318-08, BUILDING CODE REQUIREMENTS
FOR STRUCTURAL CONCRETE AND COMMENTARY.
2. CONCRETE MATERIALS SHALL CONFORM TO THE FOLLOWING STANDARDS, LATEST EDITION:
PORTLAND CEMENT................ASTM C150, TYPE I OR II
AGGREGATES..........................ASTM C33
3. ALL CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH EQUAL TO AT LEAST 4,000 PSI WITHIN 28
DAYS AFTER PLACING.
4. ALL METAL REINFORCEMENT SHALL CONFORM TO ASTM A615, GRADE 60, WITH A MINIMUM YIELD
STRENGTH OF 60,000 PSI, UNO, EXCEPT REINFORCEMENT TO BE WELDED SHALL CONFORM TO
ASTM A706, GRADE 60.
5. ALL REINFORCING BARS SHALL BE DETAILED, BOLSTERED, AND SUPPORTED IN ACCORDANCE
WITH ACI 315-05.
6. ALL REINFORCING BARS SHALL BE SECURELY ANCHORED TO THE FORMS AND SPACED FROM
THEM AS FOLLOWS:
a) FOR CONCRETE NOT EXPOSED DIRECTLY TO THE GROUND OR WEATHER, 3
4” IN SLABS AND
WALLS; 11
2” IN PIERS, COLUMNS, GIRDERS, AND BEAMS.
b) FOR CONCRETE EXPOSED TO THE GROUND OR WEATHER OR AGAINST EXISTING CONCRETE, 2" IN SLABS, WALLS, PIERS, AND COLUMNS; 3" ABOVE BOTTOM OF FOOTINGS.
7. POST INSTALLED ADHESIVE ANCHORS IN CONCRETE SHALL BE HILTI HY-150 MAX OR APPROVED
EQUIVALENT.
STEEL:
1. ALL STRUCTURAL STEEL AND STRUCTURAL STEEL WORK SHALL COMPLY WITH THE THIRTEENTH
EDITION OF THE A.I.S.C. STEEL CONSTRUCTION MANUAL, AND ANSI/AISC 360-05 SPECIFICATION
FOR STRUCTURAL STEEL BUILDINGS.
2. ALL STRUCTURAL STEEL SHALL BE ASTM A572, GRADE 50, EXCEPT ALL STRUCTURAL TUBING SHALL BE MANUFACTURED TO Fy=46 KSI (RECTANGULAR) OR Fy=42 KSI (ROUND) UNDER ASTM
A500, GRADE B.
3. ALL MISCELLANEOUS STEEL AND S SHAPES SHALL BE ASTM A36, EXCEPT ALL PIPE COLUMNS SHALL BE MANUFACTURED TO Fy=35 KSI UNDER ASTM A53, GRADE B.
4. ALL WELDS, WELDING, AND GAS CUTTING SHALL BE IN ACCORDANCE WITH THE SPECIFICATIONS OF "AWS D1.1," USING E7OXX ELECTRODES, UNO. ALL WELDERS SHALL BE CURRENTLY CERTIFIED.
ALL SHOP WELDING SHALL BE DONE BY AN APPROVED FABRICATOR AS PER THE IBC.
5. ALL BOLTS SHALL BE ¾” DIAMETER A325 BOLTS, EXCEPT THAT ANCHOR BOLTS SHALL BE A307
BOLTS WITH DIAMETERS AS SPECIFIED. ALL BOLTED CONNECTIONS SHALL HAVE WASHERS AS
PER THE A.I.S.C. SPECIFICATIONS. ALL STEEL TO STEEL CONNECTIONS SHALL BE TIGHTENED
ACCORDING TO AISC SPECIFICATIONS AND LOAD INDICATOR WASHERS SHALL BE USED ON ALL
SLIP CRITICAL TYPE CONNECTIONS.
6. ALL FULL PENETRATION WELDS SHALL BE ULTRASONICALLY OR RADIOGRAPHICALLY TESTED.
EXPLOSIVE SAFETY DESIGN:
1. EXPLOSIVE SAFETY DESIGN LOADS FOR DOOR AND NEW HEADWALL OF MAGAZINES ARE
PRESCRIBED BY DoD 6055.09-M, CHANGE: 12 MARCH 2012. DESIGN GUIDANCE IS PROVIDED BY UFC 3-340-02
(5 DECEMBER 2008).
2. FOR 7-BAR EARTH MAGAZINES (ECMs) WITH A 500,000 LB NET EXPLOSIVE WEIGHTS (NEW) OF HD 1.1
MATERIAL THE TRIANGULAR PULSE LOAD VALUES ARE:
MEMBER PEAK PRESSURE DURATION
DOOR, HEADWALL, HEADER, PILASTER 101.5 PSI 21.74 MS
3. APPROVED LOCATION AND STORAGE CAPACITY OF EACH ECM SHALL BE DETERMINED BY THE
SAFETY OFFICER BASED ON ORIENTATION AND PROXIMITY RELATIVE TO NEARBY
FACILITIES/MAGAZINES.
BASIS OF DESIGN:
APPLICABLE STANDARDS:
GOVERNING BUILDING CODES:
2009 INTERNATIONAL BUILDING CODE (IBC)
UFC 3-301-01 (31 JANUARY 2011) STRUCTURAL ENGINEERING
UFC 3-310-04 (1 MAY 2012) SEISMIC DESIGN FOR BUILDINGS
UFC 1-200-01, (20 NOVEMBER 2011): GENERAL BUILDING REQUIREMENTS
BUILDING OCCUPANCY CATEGORY.................... III
(FOR STRUCTURES CONTAINING EXPLOSIVE MATERIAL)
LIVE LOAD:
FLOOR.......................................................................20,000 LB WHEEL LOAD
OVER 65 SQUARE INCH AREA
SNOW LOAD:
GROUND SNOW LOAD, PF..................................... 60 PSF
SNOW EXPOSURE FACTOR, CE........................... 1.0
SNOW IMPORTANCE FACTOR, IS......................... 1.10
THERMAL FACTOR, CT.......................................... 1.0
WIND DESIGN:
BASIC WIND SPEED (3-SECOND GUST)...............130 MPH
WIND IMPORTANCE FACTOR, IW..........................1.15
WIND EXPOSURE................................................... C
INTERNAL PRESSURE COEFFICIENT...................+/- 0.18 (ENCLOSED)
SEISMIC DESIGN:
SEISMIC IMPORTANCE FACTOR, IE......................1.25
MAPPED MCE, SS....................................................1.95g MAPPED MCE, S1.....................................................0.75g
SITE CLASS..............................................................D
DESIGN, SDS............................................................1.30g DESIGN, SD1............................................................0.75g
SEISMIC DESIGN CATEGORY................................D
BASIC SEISMIC FORCE-RESISTING SYSTEM FOR NEW CONSTRUCTION:
SPECIAL REINFORCED CONCRETE SHEAR WALLS FOR BEARING WALL SYSTEM.
RESPONSE MODIFICATION COEFF, R
SEISMIC RESPONSE COEFF, CS...........................0.325
ANALYSIS PROCEDURE:
EQUIVALENT LATERAL FORCE PROCEDURE
ABBREVIATIONS:
AB DENOTES "ANCHOR BOLT".
DBA DENOTES "DEFORMED BAR ANCHOR".
FSE DENOTES "FINISH SLAB ELEVATION".
FV DENOTES "FIELD VERIFY".
ILD DENOTES "INTERNAL LOCKING DEVICE (NAVFAC ESC)
LLH DENOTES "LONG LEG HORIZONTAL".
LLV DENOTES "LONG LEG VERTICAL".
NIC DENOTES "NOT IN CONTRACT".
NTS DENOTES "NOT TO SCALE".
OC DENOTES "ON CENTER".
TF DENOTES "TOP OF FOOTING ELEVATION".
TOS DENOTES "TOP OF STEEL ELEVATION".
TP DENOTES "TOP OF PIER ELEVATION".
TW DENOTES "TOP OF WALL ELEVATION".
UNO DENOTES "UNLESS NOTED OTHERWISE".
WAS DENOTES "WELDED ANCHOR STUD".
(E) DENOTES "EXISTING" CONSTRUCTION.
NOTE:
DETAILS FOR CONSTRUCTION OF THE DOOR TRENCH
AND JAMB EMBEDMENTS AND THE INTERNAL LOCKING
DEVICE WERE PREPARED BY THE GOVERNMENT.
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
23A1 DEMOLITION PLAN
SCALE: 1/4" = 1'-0"
(E) FOOTING
(E) CONC
PAVEMENT
TO REMAIN
REMOVE (E) 1'-0"
THICK PAVEMENT
FOR NEW FOOTING
10'-0"
CLEAR OPENING
(E) HIGH POINT OF
FLOOR, EL. 100'-0"
(E) CONC WALL
REMOVE
(E) HINGED
TRENCH
PLATE COVER
13'-3" 13'-3"
2'-31 4" 2'-31
4"
18'-0"±
8'-3" 8'-3"
(E) 6"
DRAIN
TILE,
TYP
(E) GRADE
CONTOUR LINES
A1 DEMOLITION FRONT ELEVATION
SCALE: 1/4" = 1'-0"
(E) 1'-0" CONC WALL
LIMITS OF EARTH FILL
(E) DRAIN
TILE, TYP
10'-0"
CLEAR OPENING
REMOVE (E) BRACKETS &
HINGE ASSEMBLIES, TYP
REMOVE (E) PAIR OF 47
8"
STEEL SWINGING DOORS
REMOVE
(E) HYDRAULIC
JACKS, TYP
(E) OUTLET
SLEEVE, TYP
(E) 6" Ø PIPE
SLEEVE, TYP
REMOVE (E) CONC DOOR
POCKET 1'-0" HIGH x 81
8" DEEP
FLUSH W/ (E) FOUNDATION WALL
REMOVE (E) CONC CANOPY
1'-01
2" HIGH x 8" DEEP FLUSH
W/ (E) PILASTERS
FINISH GRADE
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
23A1 FOOTING & FOUNDATION PLAN
SCALE: 1/4" = 1'-0"
C1 ROOF PLAN
SCALE: 1/4" = 1'-0"
(E) CONC ARCH
ROOF SLAB
NEW CONC WALL
(E) CONC PAVEMENT
NEW SECURITY SCREEN
IN VENTILATION OPENING
NEW METAL CANOPY,
SEE SHEET S-502 FOR
ADDITIONAL INFORMATION.
10'-0"
CLEAR OPENING
(E) HIGH POINT OF
FLOOR, EL. 100'-0"
(E) CONC WALLWALL MOUNTED
OPERATOR W/
WEATHERPROOF
ENCLOSURE
13'-3" 13'-3"
(E) FOOTING
(E) CONC WALL
2'-31 4" 2'-31
4"
6'-1"5'-0"8'-11" 5'-0"
2" 6"
14'-7"21'-0"
3'-6"3'-6"
TRACK BEAM
NEW CONC WALL
NEW CONC FOOTING DOOR GUIDE, TYP,
SEE SHEET W-601
26'-6"
NEW CONC SLAB
W/ TRENCH
NEW TRENCH
DRAIN PIPING, TYP
NEW TRENCH COVER
FOR CLOSED POSITION
DOOR, SEE SHEET W-506
NEW TRENCH
COVER FOR OPEN
POSITION DOOR,
SEE SHEET W-406
3'-7"
LEACH BED
NEW SECURITY HOOD,
SEE SHEET S-502 FOR
ADDITIONAL INFORMATION.
NEW VENT OPENING, SEE
A2/S-504 FOR ADDITIONAL
INFORMATION, TYP
FINISH GRADE
CONTOUR LINES
CONTINUE 6" Ø DRAIN
TILE OPENING THRU
NEW CONC WALL
CONTINUE GUTTER
OUTLET THRU NEW
CONC WALL TO DRAIN
INTO NEW DOOR TRENCH
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
23A1 FRONT ELEVATION
SCALE: 1/4" = 1'-0"
CONTINUE GUTTER
OUTLET THRU NEW
CONC WALL, TYP
8'-6" 6'-1"12'-6"
EL. 100'-0"
(E) 12" CONC WALL
LIMITS OF EARTH FILL
FINISH GRADE
10'-0"
CLEAR OPENING
8'-6"
9'-7"16'-0" 6"
MIN
6"
MIN
CONTINUE 6" Ø DRAIN
TILE OPENING THRU
NEW CONC WALL
SOIL REPLACEMENT
TOP OF WALL
EL. = 114'-83
4"
TOP OF POCKET
EL. = 110'-0"
NEW VENT OPENING, SEE
SHEET S-504 FOR ADDITIONAL
INFORMATION, TYP
NEW METAL CANOPY,
SEE SHEET S-502 FOR
ADDITIONAL INFORMATION
9'-0"
NEW CONC FOOTING
NEW TRENCH
DRAIN, TYP
NEW CONC WALL
22'-0" LEACH BED
NOTE:
SLIDING DOOR NOT
SHOWN FOR CLARITY.
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
(E
) C O
N C
S
LA
B O
N G
R A
D E
6"
S E
A
LA
N T
A P
P
LY
L
IQ
U
ID
M E
M B
R A
N E
B O
N D
B R
E A
K E
R T
O (E
) C O
N C
S U
R
FA
C E
P R
IO
R
T O
P
LA
C
IN
G N
E W
C O
N C
#4 D
O W
E L
W / S
TD
H
O O
K
2"
O C
8" Ø
G U
TT
E
R T
R
EN
C H
W / 1 8"
P
ER
F O
O T
S
LO
P E
A T
O U
TL
E
T, M
A
TC
H (E
) G U
TT
E
R
6" Ø
C A
S T
IR
O
N P
IP
E
E X
TE
N
S
IO
N W
/ W A
LL
FL
A N
G E
A N
D G
R A
TI
N
G
#4
2"
O C
A
D E
TA
IL
S C
A
LE
: 1
'-0
S E3
-A
1.
dw g
1' -0
E L.
'-0
1 8"
1' -5
8"
E L.
V
A R
IE
S
(E ) C
O N
C A
R C
H R
O O
F S
LA
B
(E ) 1
2" C
O N
C W
A
LL
1' -3
1' -8
51 8"
1' -3
8"
2' -3
5' -9
6" M
IN
2' -0
8"
TR
A
C K
B E
A M
, S E
E S
-5
TO
P
O F
W A
LL
E
L.
'-8
4"
R O
U G
H E
N (E
) C O
N C
S U
R
FA
C E
T O
1 4" A
M P
LI
TU
D E
A T
FO
O
TI
N
G O
N
LY
(E ) F
LO
O
R , E
L.
9'
-1 01 2"
A T
AR
C
H W
AL
L
R
EM
O V
E (E
) W A
LL
F
LA
N
G E
G
R A
TI
N
G A
T O
U
TL
E T
P
IP
E
(E ) C
A S
T
IR
O N
P
IP
E
D O
W E
LS
T
O M
A
TC
H V
E R
T B
A R
S
IZ
E
S P
A C
IN
G
, S
TA
G G
E R
S P
LI
C
ES
E
V E
R Y
O
TH
E R
B A
R , E
A C
H F
AC
E
G R
A D
E
N E
W C
O N
C W
A
LL
S
E E
D E
TA
IL
C 1/
S -3
(4 x
C O
N T
#5
2"
O C
TR
EN
C H
E M
BE
D
M
EN
T W
H
IN
G
E D
C O
V E
R P
LA
TE
S , S
E E
D E
TA
IL
C C
/W -1
W -5
#5 x
'-6
2" O
C
#5
2"
O C
N E
W M
E
TA
L C
A N
O P
Y , S
E E
S H
E E
T S
-5
F O
R A
D D
IT
IO
N A
L
IN
FO
R
M A
TI
O
N
N A
TU
R
A L
S O
IL
B
A C
K
FI
LL
S
TI
R R
U P
S R
EQ
D
O N
LY
W
IT
H
IN
A
R C
H S
TR
U
C
TU
R E
2" Ø
S C
H
PV
C
TR
E N
C H
D R
A
IN
P
IP
E . S
LO
P
E H
O R
IZ
R
U N
1 4" P
ER
F
O O
T
N E
W C
O N
C F
O O
TI
N
G
R
EI
N F
A S
PE
R
D E
TA
IL
A 1/
S -3
S O
IL
R
E P
LA
C
E M
E N
T W
/ L E
A N
C O
N C
F
IL
L O
R G
E O
FO
A
M A
T C
O N
TR
A
C
TO
R 'S
O P
TI
O
N
LE
A
C H
B E
D W
R A
P
IN
F
IL
TE
R
F
AB
R
IC
4" Ø
P E
R
FO
R A
TE
D
S C
H
PV
C D
R
AI
N C
O
LL
E C
TO
R
P
IP
E
2' -0
P O
O R
LY
G
R A
D E
D
4" A
G G
R E
G A
TE
F
IL
L
N E
W V
E N
T O
P E
N
IN
G
S E
E D
E
TA
IL
A
2/ S
-5
TR
A
C K
B E
A M
(E ) G
U
TT
E R
T R
E N
C H
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
(E
) C O
N C
S
LA
B O
N G
R A
D E
6"
S E
A
LA
N T
A P
P
LY
L
IQ
U
ID
M E
M B
R A
N E
B O
N D
B R
E A
K E
R T
O (E
) C O
N C
S U
R
FA
C E
P R
IO
R
T O
P
LA
C
IN
G N
E W
C O
N C
#4 D
O W
E L
W / S
TD
H
O O
K
2"
O C
6" Ø
C A
S T
IR
O
N P
IP
E
E X
TE
N
S
IO
N W
/ W A
LL
FL
A N
G E
A N
D G
R A
TI
N
G
#4
2"
O C
A
D E
TA
IL
S C
A
LE
: 1
'-0
S E3
-A
1.
dw g
1' -0
E L.
'-0
E L.
V
A R
IE
S
(E ) C
O N
C A
R C
H R
O O
F S
LA
B
(E ) 1
2" C
O N
C W
A
LL
1' -3
4"
1' -3
8"
2' -2
8"
2' -9
6" M
IN
TO
P
O F
W A
LL
E
L.
'-8
4"
R O
U G
H E
N (E
) C O
N C
S U
R
FA
C E
T O
1 4" A
M P
LI
TU
D E
A T
FO
O
TI
N
G O
N
LY
R
EM
O V
E (E
) W A
LL
F
LA
N
G E
G
R A
TI
N
G A
T O
U
TL
E T
P
IP
E
(E ) C
A S
T
IR
O N
P
IP
E
D O
W E
LS
T
O M
A
TC
H V
E R
T B
A R
S
IZ
E
S P
A C
IN
G
, S
TA
G G
E R
S P
LI
C
ES
E
V E
R Y
O
TH
E R
B A
R , E
A C
H F
AC
E
G R
A D
E
TO
P
O F
W A
LL
E
L.
V A
R
IE
S
N E
W C
O N
C W
A
LL
S
E E
D E
TA
IL
C 4/
S -3
#6 x
C O
N T
4" O
C
#6 x
R E
Q D
W / S
TD
H
O O
K
2"
O C
. U
SE
H
IL
TI
H
IT
-H
Y
M
A X
W
71 2" E
M B
E D
IN
TO
(E ) C
O N
C
S O
IL
R
E P
LA
C
E M
E N
T W
/ L E
A N
C O
N C
F
IL
L O
R G
E O
FO
A
M A
T C
O N
TR
A
C
TO
R 'S
O P
TI
O
N
#4 x
C O
N T
A
LO
N G
S
LO
PE
N A
TU
R
A L
S O
IL
B
A C
K
FI
LL
(E ) F
LO
O
R , E
L.
9'
-1 01 2"
A T
AR
C
H W
AL
L
(E ) G
U
TT
E R
T R
E N
C H
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
A P
P
LY
L
IQ
U
ID
M E
M B
R A
N E
B O
N D
B R
E A
K E
R T
O (E
) C O
N C
S U
R
FA
C E
P R
IO
R
T O
P
LA
C
IN
G N
E W
C O
N C
A
D E
TA
IL
S C
A
LE
: 1
'-0
S E3
-A
1.
dw g
1' -0
(E ) 1
2" C
O N
C W
A
LL
1' -3
1' -6
1' -0
6'
-6
9' -0
5' -9
6" M
IN
TO
P
O F
W A
LL
E
L.
'-8
4"
R O
U G
H E
N (E
) C O
N C
S U
R
FA
C E
T O
1 4" A
M P
LI
TU
D E
A T
FO
O
TI
N
G O
N
LY
D O
W E
LS
T
O M
A
TC
H V
E R
T B
A R
S
IZ
E
S P
A C
IN
G
, S
TA
G G
E R
S P
LI
C
ES
E
V E
R Y
O
TH
E R
B A
R , E
A C
H F
AC
E
G R
A D
E
N E
W C
O N
C W
A
LL
, R E
IN
F
W
" O
C E
AC
H
W
AY
E
A C
H F
A C
E
#6 x
C O
N T
4" O
C
#6 x
R E
Q D
W / S
TD
H
O O
K
2"
O C
. U
SE
H
IL
TI
H
IT
-H
Y
M
A X
W
71 2" E
M B
E D
IN
TO
(E ) C
O N
C
SO
IL
R
EP
LA
C
EM
EN
T W
LE
A N
C O
N C
F
IL
L O
R G
E O
FO
A
M A
T C
O N
TR
A
C
TO
R 'S
O P
TI
O
N
6"
S E
A
LA
N T
#4
2"
O C
E L.
V
A R
IE
S
#4 D
O W
E L
W / S
TD
H
O O
K
2"
O C
N E
W M
E
TA
L C
A N
O P
Y , S
E E
S H
E E
T S
-5
F O
R A
D D
IT
IO
N A
L
IN
FO
R
M A
TI
O
N
N A
TU
R
A L
S O
IL
B
A C
K
FI
LL
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
23A1 DETAIL
SCALE: 1" = 1'-0"
SE307-A1.dwg
2"
6" 8"
CONC BEAM
STIRRUPS
PILASTER TIES @ 6" OC
CONT THRU BEAM JOINT
3'-6" PILASTER
EL. = 114'-83
4"
A4 PILASTER DETAIL
SCALE: 1" = 1'-0"
SE307-A4.dwg
NEW CONC PILASTER,
SEE DETAIL C4/S-307
3'-6"
(3) #5 VERTS ABOVE
DOOR POCKET
(3) #5 x 4'-8" @ 6" OC
CENTERED AT
EMBED PLATE
TRACK BEAM
CONSTRUCTION JOINT.
DO NOT ROUGHEN SURFACE
3"
C1 PILASTER DETAIL
SCALE: 1" = 1'-0"
SE307-C1.dwg
(E) 1'-3" CONC WALL
NEW CONC WALL, REINF W/
#4 @ 6" OC EACH WAY, EACH
FACE W/ #4 STIRRUP @ 6" OC
EACH INTERSECTION
STAINLESS STEEL
PLATE 12"x4" x CONT
SLIDING DOOR
(E) STEEL ANGLE
NEW CONC PILASTER,
REINF W/ (16) #9 VERTS
PLACED AS SHOWN &
(2) #5 BUNDLED TIES
@ 6" OC & (4) #5 CROSS
TIES @ 6" OC
4"2'-0"
#4 x 1'-6" DBA @ 24" OC
3'-6"
#3 x VERT
STAINLESS STEEL
PLATE 12"x8" x CONT
8" Ø x 12" WAS @ 18" OC
2"
8" Ø x 9" WAS
@ 18" OC,
STAGGER W/
DIAGONAL WAS
C4 PILASTER DETAIL
SCALE: 1" = 1'-0"
SE307-C4.dwg
(E) 1'-3" CONC WALL
(E) STEEL ANGLE
JAMB EMBEDMENT,
SEE SHEET W-301
3'-6"
NEW CONC WALL, REINF W/ #4 @ 6" OC
EACH WAY, EACH FACE W/ #4 STIRRUP
@ 6" OC EACH INTERSECTION
4" 2'-0"
NEW CONC PILASTER, REINF W/
(16) #9 VERTS PLACED AS SHOWN
& (2) #5 BUNDLED TIES @ 6" OC &
(4) #5 CROSSTIES @ 6" OC
NEW CONC PILASTER,
REINF W/ (14) #5 VERTS &
(3) #4 TIE SETS @ 12" OC
#4 x 1'-6" DBA @ 24" OC
#3 VERT
ILD COMPARTMENT HORIZONTAL
WELDMENT, SEE SHEET W-201.
WRAP W/ HEAT TRACE CABLE, SEE E-103
1'-4" 10"
CONSTRUCTION JOINT.
DO NOT ROUGHEN SURFACE
1'-03 8" 85
8"
4" Ø CORE HOLES THRU (E) PILASTER. FILL GAP
BETWEEN PIPE SLEEVE & CORE WALLS W/
EPOXY PRIOR TO POURING NEW CONC PILASTER.
ADDITIONAL #5 VERT ABOVE
& BELOW ILD COMPARTMENT
6"
1'-4"
STAINLESS STEEL L6x3x1 2 x CONT
W/ 5 8" Ø x 12" WAS @ 12" OC
(3) POSITIONING BRACKETS BENT PLATE
9x4x3
8x0'-9" W/ (2) 5 8" Ø HILTI HY150 MAX @ 6" OC (6" EMBED) & (1) 916"x11
4" HORIZ
SLOTTED HOLE FOR THREADED BOLT
DOUBLE NUT AT THREADED
BOLTS ON JAMB EMBED
STAINLESS STEEL 31
2" Ø FLANGED
PIPE SLEEVES, SEE W-307. EXTEND
FROM INTERIOR FACE OF (E) CONC
TO INTERMEDIATE FACE OF NEW
CONC PILASTER, AS SHOWN.
ACTUATOR PLATE, SHOWN FOR REFERENCE.
GOVERNMENT PROVIDED & INSTALLED.
SLIDING DOOR
RECESSED DOOR CONTROLLER
BOX, SEE SHEET E-102
5"5"
BOLT PIPE SLEEVE FLANGE
TO (E) FACE OF CONC, TYP
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
23A1 DOOR ELEVATION
SCALE: 1/4" = 1'-0"
DOOR OPERATION NOTES:
1. DOOR MANUFACTURER SHALL DESIGN HEAVY DUTY TROLLEYS AND
HANGERS FOR 3.5 TON MINIMUM RATED CAPACITY.
2. DOOR OPERATOR MANUFACTURER SHALL COORDINATE WITH DOOR
MANUFACTURER TO ENSURE THE THAT OPERATOR AND THE DOOR ARE
COMPATIBLE.
3. A MEANS OF MANUAL OPERATION SHALL BE MADE AVAILABLE IF POWER IS
LOST TO THE OPERATOR.
4. DOOR OPERATOR SHALL MOVE DOOR AT A SPEED OF 13 TO 18 FT/MIN.
MAXIMUM SPEED OF DOOR SHALL NOT EXCEED DOOR OPERATOR AND
DOOR MANUFACTURER'S RECOMMENDATIONS.
5. MOTOR SHALL OPERATE NORMALLY AT NO MORE THAN 75 PERCENT OF
RATED CAPACITY.
6. MOTOR SHALL BE VARIABLE SPEED THAT WILL RAMP UP TO FULL
OPERATING SPEED.
7. COMPLETE DOOR OPERATOR SYSTEM (MOTOR, DRIVE, GEARS, CHAIN
ETC.) SHALL BE DESIGNED/RATED FOR OUTDOOR USE TAKING INTO
CONSIDERATION SITE SPECIFIC ENVIRONMENTAL CONDITIONS SUCH AS
EXPOSURE TO FREEZING AND CORROSIVE ENVIRONMENTS.
8. LIMIT SWITCHES - TYPE: MECHANICALLY ACTUATED LIMIT SWITCH SHALL
STOP DOOR AT END OF TRAVEL (OPEN AND CLOSE POSITIONS).
9. REFER TO UFGS 41 22 23.19 (MONORAIL HOIST) AND MIL-HDBK-1013-11
(INSTRUCTIONS FOR PLANNING AND DESIGN OF HIGH SECURITY
MAGAZINE DOOR CONSTRUCTION PROJECTS) FOR ADDITIONAL GUIDANCE.
9'-3"
10'-0"
CLEAR OPENING
9'-7"16'-0" 6"
MIN
6"
MIN
11'-31 2"
DOOR OPEN
POSITION
11'-31 2"
DOOR CLOSED
POSITION
(E) 12" CONC WALL
LIMITS OF EARTH FILL
(E) FLOOR
EL. = 100'-0"
TOP OF DOOR
TOP OF BEAM
TOP OF WALL
EL. = 114'-83
4"
11'-0"7"
ADJUSTABLE
TROLLEY STOP
EACH END
WALL MOUNTED
OPERATOR W/
WEATHERPROOF
ENCLOSURE
NEW METAL CANOPY
NOT SHOWN FOR
CLARITY
NEW CONC
WALL
TROLLEY
TRACK
BEAM
S10x35
EL. = 109'-111
4"
EL. = 112'-3"
SLIDING DOOR
SEE S-701
2"
FINISH GRADE
NOTE:
WELD TRACK BEAM AND SHIMS IN PLACE
AFTER NECESSARY ADJUSTMENTS HAVE
BEEN MADE USING BOLTS IN SLOTTED HOLES.
NOTE:
TRACK BEAM, SUPPORT BRACKETS, BOLTS, AND
ANCHOR BOLT PROJECTIONS SHALL BE GALVANIZED.
C1 DETAIL
SCALE: 1 1/2" = 1'-0"
SE501-C1.dwg
2"
6"21 2"
STAINLESS STEEL
PLATE 12"x4" x CONT
STAINLESS STEEL
L31
2x31 2x1
2 x CONT
EDGE OF HEADER
BEAM BUMP-OUT
EDGE OF PILASTER
BUMP-OUT
STAINLESS STEEL
PLATE 12"x8" x CONT
NOTE:
SLIDING DOOR AND
SECURITY HEADER ANGLE
NOT SHOWN FOR CLARITY. EDGE OF
OPENING
C4 DETAIL
SCALE: 1 1/2" = 1'-0"
SE501-C4.dwg
STAINLESS STEEL EMBED
PLATE 1"x10"x1'-0" W/
(4) 7 8" Ø WAS (9" EMBED)
STEEL BEAM, SEE ELEVATION.
MAY COPE INNER FLANGES
AS REQD TO ACCOMMODATE
BOLT FASTENING
(2) STAINLESS STEEL
SHEAR PLATE 516"x4"x0'-6"
W/ (2) 3 4" Ø A325 BOLTS
CONC PILASTER, SEE
DETAIL A4/S-307
2"
SECTION A-A
TRACK
BEAM
2" SHIM
PACK
6"2" 2"
5"
8"
D2 DETAIL
SCALE: 1 1/2" = 1'-0"
SE501-D2.dwg
2'-07 8"
W8x18
SHEAR PLATE
8"x31 2"x0'-6" W/
(2) 3 4" Ø A325
BOLTS
4"
TRACK BEAM
TRACK BEAM
PLATE 13
8"x12"x1'-6"
W/ (4) 7 8" Ø x14"
ANCHOR BOLTS
(10" MIN EMBED)
(2) 13 16"x4" SLOTTED HOLES ONE
EACH SIDE OF W8 BEAM WEB FOR
(4) 3 4" Ø A325 BOLTS W/ LOCK &
BEVEL WASHERS. COORDINATE W/
TROLLEY MANUFACTURER SPECS
NEW CONC WALL
2" SHIM PACK
STIFF PLATE 516" x REQD, EACH SIDE
4"
D4 DETAIL
SCALE: 1 1/2" = 1'-0"
SE501-D4.dwg
2"9"11
2"
5"
PLATE 11
4"x12"x1'-0"
W/ (4) 7 8" Øx14"
ANCHOR BOLTS
(10" MIN EMBED)
PLATE 1"x11"x1'-0" W/ (2) 13
16"x4"
SLOTTED HOLES
(2) STIFFENER
PLATES 516" x REQD
SECTION A-A
8"
TRACK
BEAM
TRACK BEAM
(2) 13 16"x4" SLOTTED
HOLES FOR
(4) 3 4" Ø A325
BOLTS W/ LOCK &
BEVEL WASHERS
COORDINATE W/
TROLLEY
MANUFACTURER
SPECS
NEW CONC WALL
2" SHIM PACK 23
4"23 4"
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
26'-0"
(E) CONC WALL
A1 CANOPY PLAN
SCALE: 1/2" = 1'-0"
CANOPY FRAME
3 EQUAL SPACES @ 5'-1"± = 15'-4"
HSS3x3x3
L3x3x1 4 x CONT
BENT PLATE
4"x3"x5
16" x BTWN HSS
CANOPY FRAMES
L3x3x1 4 x CONT
BENT PLATE 4"x3"x5
16" HIGH
& L3x3x1 4 LOW x BTWN HSS
CANOPY FRAMES
HSS3x3x3 16 HSS3x3x3
NEW CONC WALL
NEW SECURITY
HOOD
METAL CANOPY FRAMING NOTES:
1. FRAMING MEMBERS SHALL BE ASTM A500, GRADE B TUBES WITH
fy = 46 KSI. ALL FRAMING MEMBER SHALL BE HSS3x3x3
16, UNO.
2. FRAMING MEMBERS SHALL BE GALVANIZED. REPAIR OF
DAMAGED AND UNCOATED AREAS SHALL FOLLOW ASTM A780.
3. METAL CANOPY ROOF DECK AND SIDE PANELS SHALL BE 11
2"
DEEP, 18 GAUGE MINIMUM STEEL PANELS WITH fy = 38 KSI
MINIMUM. PANELS SHALL ABLE TO RESIST AN UPLIFT WIND
FORCE OF 86 PSF AND ROOF SNOW LOAD OF 120 PSF.
4. THE PANEL SHALL BE GALVANIZED AND PAINTED WITH PRIMER.
PAINT COLOR TO BE APPROVED BY CONTRACTING OFFICER'S
REPRESENTATIVE.
5. CANOPY AND SECURITY HOOD FRAMING AND ANCHOR BOLT
PROJECTIONS SHALL BE GALVANIZED.
PROVIDE METAL
EAVE TRIM W/ SAME
FINISH AS SIDING
PRE-FINISHED
METAL ROOF DECK,
SEE NOTE #3
HSS3x3x1 4 HSS3x3x1
NEW METAL
CANOPY
CANOPY FRAME
2 EQUAL SPACES @ 5'-1"± = 10'-2"
EQ EQ EQ EQ
HSS3x3x1
HANGER, TYP
C1 CANOPY FRAME
SCALE: 1" = 1'-0"
SE502-C1.dwg
(E) CONC WALL
NEW CONC WALL
TRACK BEAM
4'-0"
TOP OF
TRACK BEAM
EL. = 112'-3"
TOP OF WALL
114'-83
4"
HSS3x3x3
CANOPY FRAME
PRE-FINISHED
METAL DECK
1 12
PIGEON
SCREEN
C3 CANOPY FRAME
SCALE: 1" = 1'-0"
SE502-C3.dwg
(E) CONC WALL
NEW CONC BEAM
TRACK BEAM
2'-6"
TOP OF
TRACK BEAM
EL. = 112'-3"
TOP OF WALL
114'-83
4"
1 12
HSS3x3x3
CANOPY FRAME
PRE-FINISHED
METAL DECK
1'-3"
SECURITY HOOD
FRAMING
(E) CONC BEAM
PIGEON SCREEN
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
23A1 DETAIL
SCALE: 1 1/2" = 1'-0"
SE503-A1.dwg
FACE OF CONC PILASTER
L3x3x1 4 x CONT W/
8" Ø HILTI HY150 MAX
@ 16" OC (6" EMBED)
PRE-FINISHED
METAL DECK
TOP OF
TRACK BEAM
EL. = 112'-3"
HSS3x3x1 4 x REQD
HSS3x3x1 4 x REQD
PLATE 3 8"x3"x0'-9" W/
(2) 5 8" Ø HILTI HY150
MAX (6" EMBED)
NOTE:
FRONT PLATE NOT SHOWN FOR
CLARITY. FRONT PLATE TO
EXTEND TO FACE OF PILASTER.
3" MAXPLATE 3 8"x3"x0'-9" W/
(2) 5 8" Ø HILTI HY150
MAX (6" EMBED)
A4 DETAIL
SCALE: 1 1/2" = 1'-0"
SE503-A4.dwg
HSS CANOPY FRAME
TOP OF
TRACK BEAM
EL. = 112'-3"
HSS BEAM, SEE PLAN
HSS3x3x1
4 HANGER
HSS3x3x1 4 x REQD
FRONT PLATE 3 8"
3" 3"
HSS HSS
HSS3x3x3
16 KICKER
FACE OF CONC WALL
STEEL PLATE
2"x3"x3'-61 2" W/
(5) 5 8" Ø HILTI
HY150 MAX @
16" OC (6" EMBED)
PRE-FINISHED
METAL DECK
HSS CANOPY
FRAME, SEE PLAN
C1 DETAIL
SCALE: 1 1/2" = 1'-0"
SE503-C1.dwg
FACE OF CONC PILASTER
C2 DETAIL
SCALE: 1 1/2" = 1'-0"
SE503-C2.dwg
PRE-FINISHED
METAL DECK
#12-14 HILTI
KWIK-PRO SDS
W/ KWIK SEAL
@ 12" OC
HSS CANOPY FRAME
HSS BEAM x BTWN
HSS CANOPY FRAME
CAP PLATE 316" x REQD HSS3x3x3
16 KICKER,
WHERE APPLIES AT
SECURITY HOOD ONLY
C3 DETAIL
SCALE: 1 1/2" = 1'-0"
SE503-C3.dwg
(2) L4x3x5 16x0'-9" W/
(4) 5 8" Ø 8" ANCHOR
(8" EMBED)
HSS CANOPY
FRAME
(2) #5 x 4'-0"
CENTERED
ON FRAME
CAP PLATE 316" x REQD
FACE OF CONC WALL NOTE: SECURITY
HOOD NOT SHOWN
FOR CLARITY.
C4 DETAIL
SCALE: 1 1/2" = 1'-0"
SE503-C4.dwg
8"
PLATE 12"
PLATE 3 8"
HSS3x3x1 4 x REQD
4" Ø SELF-TAPPING
SCREWS @ 9" OC
(REMOVABLE), TYP
NEW CONC BEAM
TOP OF
TRACK BEAM
EL. = 112'-3"
TRACK BEAM
HSS HANGER,
SEE PLAN
HSS CANOPY FRAME
HSS BEAM, SEE PLAN
L31 2x31
2x1 4x0'-21
2" W/
(1) 5 8" Ø THRU BOLT
L4x3x5 16 x CONT (LLV)
W/ (4) 5 8" Ø ANCHORS
EQUALLY SPACED
(8" EMBED)
SECTION A-A
HSS3x3x3 16 KICKER PLATE 14"x3"x0'-61
2"
W/ 5 8" Ø THRU BOLT
NOTE:
TOP PLATE NOT
SHOWN FOR CLARITY.
SECTION B-B
2"11
2"
D2 DETAIL
SCALE: 1 1/2" = 1'-0"
SE502-D2.dwg
HSS CANOPY FRAME
#12-14 HILTI
KWIK-PRO SDS
W/ KWIK SEAL
@ 8" OC
PRE-FINISHED
METAL DECK
2"
#12-14 HILTI
KWIK-PRO SDS
W/ KWIK SEAL
@ 12" OC
HSS BEAM x BTWN
HSS CANOPY FRAME
NEOPRENE
CLOSURE
D3 DETAIL
SCALE: 1 1/2" = 1'-0"
SE503-D3.dwg
(2) L4x3x5 16x0'-9" W/
(4) 5 8" Ø 8" ANCHOR
(8" EMBED)
HSS CANOPY
FRAME
(2) #5 x 4'-0"
CENTERED
ON FRAME
FACE OF CONC WALL
BENT PLATE
4"x3"x5
16" x
CONT W/ 5 8"
Ø HILTI
HY150 MAX
@ 16" OC (6"
EMBED)
METAL FLASHING
#12-14 HILTI
KWIK-PRO SDS
W/ KWIK SEAL
@ 8" OC
PRE-FINISHED
METAL DECK
CAULK
FLASHING
IN RECESS
4"8"
NEOPRENE
CLOSURE
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
23A2 DETAIL
SCALE: 1 1/2" = 1'-0"
SE504-A2.dwg
6" 6"
SECTION A-A
5" 8" 5"
2"
TYP
VENT COVER ELEVATION
2" 1'-3" 2"
9"
1'-3"
A4 DETAIL
SCALE: 1 1/2" = 1'-0"
SE504-A4.dwg
4" MIN
CLEARANCE
8"
TYP
SECTION A-A
1'-6" (FV)8" (FV) 6" (FV)
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
23A1 DOOR ISOMETRIC WITH INTERNAL REBAR/CONCRETE
SCALE: NONE
SE701-A1.dwg
HIGH SECURITY DOOR LIGHTWEIGHT CONCRETE FILL
MATERIAL AMOUNT UNITS
LIGHTWEIGHT FINE AGGREGATE 1530 LBS
CEMENT TYPE II 720 LBS
WATER 315 LBS
SILICA FUME 81 LBS
SUPER PLASTICIZER 7.14 LBS
POLYETHYLENE FIBERS 0.357 LBS
CARBON FIBERS 0.357 LBS
TOTAL WEIGHT 2646 LBS
TOTAL VOLUME 1.0 YD³
DENSITY 100-110 LBS/FT³
STRENGTH (28 DAY MINIMUM) 4,000 PSI
LIGHTWEIGHT CONCRETE NOTES:
1. LIGHTWEIGHT AGGREGATES SHOULD BE DRY.
2. ADJUST WATER AMOUNT TO +/- 22 LB SO THAT MIX HOLDS SHAPE WHEN FORMED INTO
A BALL IN THE HAND.
3. MIX CAN BE SPLIT, DOUBLED, ETC. FOR VOLUME NEEDED.
4. MIX PROCEDURE:
A. WEIGH OUT ALL MATERIALS
B. IN A SEPERATE CONTAINER, COMBINE AND MIX HALF OF WATER, PLASTICIZER
AND ALL FIBERS.
C. IN ANOTHER SEPERATE CONTAINER, COMBINE AND MIX SILICA FUME AND
CEMENT.
D. POUR WATER WITH PLASTICIZER AND ALL FIBERS INTO MIXER.
E. POUR LIGHTWEIGHT FINE AGGREGATE INTO MIXER.
F. SLOWLY ADD SILICA FUME AND CEMENT TO MIXER.
G. ADD REMAINING WATER ADJUSTING AS NECESSARY (NOTE 2).
H. ALLOW TO MIX FOR AT LEAST 10 MINUTES.
I. WHEN MIX IS READY, POUR IN TO DOOR CABITIES OVER REBAR, TO PRESRIBED
DEPTH. ENSURE MIX FILLS ALL AREAS BEHIND REBAR, VIBRATE IF NECESSARY,
NO VOIDS ALLOWED.
5. ALLOW CONCRETE TO CURE FOR 24 HOURS BEFORE MOVING DOOR.
6. QUESTIONS CAN BE REFERED TO NAVFAC ESC SECURITY ENGINEERING DIVISION CI66.
DOOR PARTS LIST
PART NO DESCRIPTION MATERIAL
1 EXTERIOR PLATE 3 8" THICK A36 LOW CARBON STEEL
2 INTERIOR PLATE 14" THICK A36 LOW CARBON STEEL
3 C CHANNEL C8x18.7 A36 LOW CARBON STEEL
4 VERTICAL STIFFENER 516" THICK A36 LOW CARBON STEEL
5 HORIZONTAL STIFFENER 516" THICK A36 LOW CARBON STEEL
6 L21 2x21
2x1
2 ANGLE A36 LOW CARBON STEEL
7 #3 REBAR, VARIOUS LENGTHS A706
8 END PLATE 12" THICK A36 LOW CARBON STEEL
9 LAP PLATE 12" THICK A36 LOW CARBON STEEL
10 PADEYE/TROLLEY HANGERS A36 LOW CARBON STEEL
11 L31 2x3x3
8x0'-85
8" ANGLE (LLH) A36 LOW CARBON STEEL
12 GUIDE ANGLES 12" THICK A36 LOW CARBON STEEL
NOTES:
1. UNLESS OTHERWISE SPECIFIED ALL DIMENSIONS ARE IN INCHES.
2. MATERIAL: ALL MATERIAL LOW CARBON STEEL PER ASTM A36 UNLESS
OTHERWISE SPECIFIED. HIGHER STEEL STRENGTHS SHALL NOT BE
SUBSTITUTED.
3. INTERPERET WELDING SYMBOLS PER ANSI/AWS A2.4. ALL WELDING SHALL BE
PER ANSI/AWS D1.1.
4. PLATES, PART NO. 1 AND 2, MAY BE SIZED DIFFERENTLY TO REDUCE THE
NUMBER OF SEAMS, 1 SEAM MAXIMUM SHOWN. ALL SEAMS SHALL BE
CENTERED OVER VERTICAL STIFFENERS.
5. FABRICATION OF DOORS SHALL CONFORM WITH AISC 360-05 AND AISC 303-05.
THE ASSEMBLED DOOR SHALL BE FABRICATED TO WITHIN 14 INCH FLATNESS IN
EITHER DIRECTION.
6. FINISH: APPLY ONE COAT OF POLYURETHANE TOP COAT. COLOR EQUIPMENT
GRAY. MASK AREA FROM TOP COAT WHERE NOTED FOR RECEIVER BLOCK TO
BE WELDED TO DOOR AFTER DOOR INSTALLATION .
DOOR PAINT:
A. PREPARATION: BLAST CLEAN TO SSPC SP10.
B. PAINT SYSTEM: SYSTEM DRY FILM THICKNESS TO BE 8.5 MILS MINIMUM
1. ZINC RICH PRIMER: MPI 19
2. EPOXY INTERMEDIATE COAT: MPI 108
3. POLYURETHANE TOP COAT: MPI 72
C. PORTIONS OF STEEL TO BE WELDED SHALL BE PAINTED AFTER WELDING.
7. DOOR SHALL BE FILLED WITH 2.0" LIGHTWEIGHT CONCRETE.
8. WEIGHT: DOOR WITH CONCRETE FILL: 10,060 LBS.
APPLY PRIMER BUT MASK
RECEIVER BLOCK AREAS
FROM TOP COAT PER NOTE 6.
SEE SHEET W-104 FOR
RECEIVER BLOCK LOCATIONS.
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
23A1 DOOR EXTERIOR ELEVATION
SCALE: 1/2" = 1'-0"
SE702-A1.dwg
11'-0"
4" 85
8"
2"
DOOR TRAILING
EDGE ELEVATION
RECEIVER BLOCK,
TYP, SEE SHEET
W-603. LOCATE PER
SHEET W-104. FIELD
WELD TO DOOR
THEN APPLY PAINT
COATS PER NOTE 6
ON SHEET S-701.
A3 DOOR INTERIOR ELEVATION
SCALE: 1/2" = 1'-0"
SE702-A3.dwg
11'-0"
5'-51 2" 5'-9"
COPE WEB
OF VERTICAL
CHANNEL TO
FIT INSIDE
PROFILE OF
HORIZONTAL
CHANNEL
PN.8
PN.9
2" RECESS
3"
PN.11
8"
DOOR LEADING
EDGE ELEVATION
6"
D1 PLATE NOTCH DETAIL
SCALE: 1 1/2" = 1'-0"
SE702-D1.dwg
3"1
2" EDGE OF
CHANNEL, PN.3
EDGE OF
PLATE, PN.8
D3 PLATE GAP DETAIL
SCALE: 1 1/2" = 1'-0"
SE702-D3.dwg
4" NOMINAL PLATE
GAP FOR BUTT WELD
MAY BE ADJUSTED
BY MANUFACTURER,
SEE NOTE 4 ON SHEET S-701.
EDGE OF
CHANNEL,
PN.3
D4 PLATE WELD DETAIL
SCALE: 1 1/2" = 1'-0"
SE702-D4.dwg
THRU HOLES
CENTERED OVER
INTERNAL TAB ANGLES
2" ± 18"
TYP
Ø2"
HOLES
2"
EDGE OF
CHANNEL, PN.3
INTERIOR
PLATE, PN.2
EXTERIOR
PLATE, PN.1
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
0.
.3
1 4" 1 4"
RIGHT PANEL
A1 INTERIOR PLATE ELEVATIONS
SCALE: 3/4" = 1'-0"
SE703-A1.dwg
LEFT PANEL
PLANPLAN
0.
.3
0.000.00
124.75
.8
6.25
127.50 127.50
122.00
114.41
6.
5.
9.
R 1 4"R 1
4"
0.
7.
.0
.3
8"
8"
RIGHT PANEL
A3 EXTERIOR PLATE ELEVATIONS
SCALE: 3/4" = 1'-0"
SE703-A3.dwg
LEFT PANEL
PLAN PLAN
0.
1.
5.
.3
9.
.9
.9
0.00 0.00
11.66 15.75 19.66 23.75 27.66 31.75 35.66 39.75 43.66 47.75 51.66 55.75 59.66 63.75 67.66 71.75 75.66 79.75 83.66 87.75 91.66 95.75 99.66 103.75
111.75 115.66
107.66
11.66 15.75 19.66 23.75 27.66 31.75 35.66 39.75 43.66 47.75 51.66 55.75 59.66 63.75 67.66 71.75 75.66 79.75 83.66 87.75 91.66 95.75 99.66 103.75
111.75 115.66
107.66
.0
.9
.0
.9
.0
.9
.0
.9
.0
.9
.0
.3
.2
.3
.2
.3
.2
.3
Ø2"
.2
.3
.2
.3
.2
.3
Ø2"
7.75
119.75119.75
7.75
124.25124.25
.8
6.25
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
23A1 DOOR EXTERIOR SECTION (PLATES REMOVED) SHOWN WITH CONCRETE
SCALE: 1/2" = 1'-0"
SE704-A1.dwg
2" 71
2"
VERTICAL STIFFENER
14 EQUAL SPACES @ 8" OC
3" 7" 5"
TAB ANGLES
14 EQUAL SPACES @ 8" OC
A3 DETAIL WITH RECESS
SCALE: 3" = 1'-0"
COMPARTMENT
SE704-A3.dwg
INTERIOR
32" 4"1
2"
6"1 2"
NOTES:
1. FINISH: INSIDE CAVITIES OF DOOR SHALL BE ABRASIVE BLASTED TO NEAR WHITE CONDITION, AND GALVANIZED TO RECEIVE PAINT. APPLY ONE COAT OF EPOXY BASED PRIMER TO ALL INSIDE SURFACES ESPECIALLY WHERE THE LIGHTWEIGHT
CONCRETE WILL BE POURED. MASK FACE OF TAB ANGLES, PART NO. 6, SEE SHEET S-701.
2. AFTER APPLICATION OF PRIMER POUR LIGHTWEIGHT CONCRETE INTO CAVITIES OF THE BACK SIDE OF THE DOOR TO A
THICKNESS OF 2". SEE DRAWING S-701 FOR DESCRIPTION OF THE LIGHTWEIGHT CONCRETE.
3. THE HORIZONTAL AND VERTICAL STIFFENERS SHALL BE CONTINUOUS OR UP TO THREE SEGMENTS FULL WELDED TOGETHER.
4. TAB ANGLES REQUIRED IN LOCATIONS SHOWN. NO MODIFICATIONS.
A4 SECTION WITH RECESS
SCALE: 3" = 1'-0"
COMPARTMENT
SE704-A4.dwg
EXTERIORINTERIOR
PLATE 14"
D1 COMPARTMENT SECTION WITH REBAR/CONCRETE
SCALE: 3" = 1'-0"
SE704-D1.dwg
LIGHTWEIGHT CONCRETE
POURED AFTER PRIMER
APPLIED TO INSIDE OF DOOR
CONCRETE FILLS TO THIS
LEVEL IN COMPARTMENTS
AT LEADING EDGE OF DOOR
REBAR
RECEIVER BLOCK, SHOWN
FOR REFERENCE ONLY
RECEIVER BLOCK,
SEE SHEET W-603
INTERIOR
EXTERIOR
D3 COMPARTMENT SECTION WITH RECESS
SCALE: 3" = 1'-0"
SE704-D3.dwg
LIGHTWEIGHT CONCRETE
POURED AFTER PRIMER
APPLIED TO INSIDE OF DOOR
CONCRETE FILLS TO THIS
LEVEL IN COMPARTMENTS
AT LEADING EDGE OF DOOR
REBAR1
2" 511
32" 4"
PLATE 14" EXTERIOR
INTERIOR
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
23A1 DOOR EXTERIOR SECTION (PLATES REMOVED) SHOWN WITHOUT CONCRETE
SCALE: 1/2" = 1'-0"
SE705-A1.dwg
6'-8" 2'-2"
COPE WEB
OF VERTICAL
CHANNEL TO
FIT INSIDE
PROFILE OF
HORIZONTAL
CHANNEL
PN.5PN.3
PN.4
PN.3
PN.3
SEE NOTE 3/S-704
& SHEET S-709
PN.8
THE CONTRACTOR SHALL BE RESPONSIBLE FOR
COORDINATING THE WORK AMONG THE
VARIOUS TRADES AS NECESSARY TO AVOID
CONFLICTS AND TO ENSURE THE INSTALLATION
OF ALL WORK WITHIN THE AVAILABLE SPACE.
A4 SECTION CONCRETE NOT SHOWN
SCALE: 1 1/2" = 1'-0"
SE705-A4.dwg
PN.4
PN.7
PN.7
PN.5
TIE REBAR
INTERSECTIONS
W/ WIRE TIES, TYP
PN.6
VERTICAL STIFFENER
PLATES, SEE DETAIL
D3/S-705 TYP
HORIZONTAL STIFFENER
PLATES, SEE DETAIL
D4/S-705 TYP
PN.11
C1 DOOR TRAILING END HEAD DETAIL
SCALE: 1 1/2" = 1'-0"
SE705-C1.dwg
PN.8
PN.9
PN.2
PN.1
C2 STIFF TO LEFT SIDE CHANNEL
SCALE: 1 1/2" = 1'-0"
SE705-C2.dwg
HORZ STIFFENER,
COPE BOTH ENDS TO
FIT INSIDE PROFILE OF
SUPPLIED CHANNEL
NOTE:
TABS AND CONCRETE NOT
SHOWN FOR CLARITY.
3"
2"
PN.8
PN.9
2"
2" NOTE:
SEE C1/S-706 FOR
ADDITIONAL INFORMATION.INTERIOR
EXTERIOR
C3 STIFF TO RIGHT SIDE CHANNEL
SCALE: 1 1/2" = 1'-0"
SE705-C3.dwg
HORZ STIFFENER,
COPE BOTH ENDS TO
FIT INSIDE PROFILE OF
SUPPLIED CHANNEL
WELD REBAR TO
CHANNEL EACH
END, TYP
NOTE:
TABS AND CONCRETE NOT
SHOWN FOR CLARITY.
C4 STIFF TO TOP CHANNEL
SCALE: 1 1/2" = 1'-0"
SE705-C4.dwg
NOTE:
CONCRETE NOT
SHOWN FOR CLARITY.
VERT STIFFENER COPE
TO FIT INSIDE PROFILE
OF SUPPLIED CHANNEL
(2) #3 CONT VERTICAL
REBAR EACH SPACE IN
ALL COMPARTMENTS
(2) #3 CONT HORIZONTAL
REBAR IN ALL
COMPARTMENTS, TACK WELD
TO VERTICAL STIFFENER
WELD REBAR TO
CHANNEL EACH END
D1 COMPARTMENT SECTION WITHOUT CONCRETE
SCALE: 3" = 1'-0"
SE705-D1.dwg
8"
3" (NO WELD THIS EDGE)ANGLES FLUSH W/
STIFFENERS, TYP
3" ± 12"
TYP
2"
TYP
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
23A1 DOOR GUIDE LOCATIONS
SCALE: 1 1/2" = 1'-0"
SE706-A1.dwg
(E) PILASTER
NEW PILASTER
NEOPRENE WEATHER
STRIP (CONT) AROUND
DOOR OPENING. FASTEN
W/ SELF TAPPING
SCREWS @ 6" OC
DOOR OUTLINE
FOR REFERENCE
DOOR GUIDE, TYP
(5 TOTAL), SEE SHEET
W-601. COORDINATE
W/ TRENCH EMBED.
INSTALL DOOR PLUMB
THEN ANCHOR GUIDES
TO TRENCH.
(E) PILASTER
NEW PILASTER
NEOPRENE WEATHER
STRIP (CONT) AROUND
DOOR OPENING. FASTEN
W/ SELF TAPPING
SCREWS @ 6" OC
2" Ø TRENCH DRAIN,
TYP (4 TOTAL) NOTE:
SEE SHEETS W-403 & W-503
FOR DOOR GUIDE AND
TRENCH DRAIN LOCATIONS.
#5 U-BAR LAPPED
W/ SLAB REINF
SHOWN ON A1/S-304
STAINLESS STEEL
GRATED DRAIN
COVER, TYP
2"
NOTE:
TRENCH COVER PLATES
NOT SHOWN FOR CLARITY.
JAMB EMBEDMENT,
SEE SHEET W-301
NON-DRIVE THRU
TRENCH EMBEDMENT
SEE SHEET W-501
DRIVE THRU
TRENCH EMBEDMENT
SEE SHEET W-401
NOTE:
SEE SHEETS
W-101 & W-102
FOR EMBEDMENTS.
6"3"1 2"
6"21 2"
C1 LEFT JAMB DETAIL
SCALE: 3" = 1'-0"
SE706-C1.dwg
3"
NEOPRENE WEATHER STRIP
(CONT) FASTEN W/ SELF
TAPPING SCREWS @ 6" OC
2"
SLIDING DOOR
2"
C3 DOOR HEAD DETAIL
SCALE: 3" = 1'-0"
SE706-C3.dwg
4"
2" 2"STAINLESS STEEL
L3x2x1
2 x CONT
(INSTALL AFTER
CENTERING BOLTS
HAVE BEEN REMOVED)
SLIDING DOOR
STAINLESS STEEL
L31
2x31 2x1
2 x CONT W/
8" Ø x 8" WAS @ 16" OC
CONC BEAM
NEOPRENE WEATHER STRIP
(CONT) EXTEND 6" PAST
OPENING FASTEN W/ SELF
TAPPING SCREWS @ 6" OC
PADEYE, SEE DETAIL
A1/S-707 FOR
ATTACHMENT
FACE OF PILASTER BEYOND
C5 THRESHOLD DETAIL
SCALE: 3" = 1'-0"
SE706-C5.dwg
STAINLESS STEEL
PLATE AT CORNER
OF NEW PILASTER,
SEE C1/S-307
DOOR GUIDE, SEE
SHEET W-601
NOTE:
TRENCH COVER PLATE
NOT SHOWN FOR CLARITY.
8" 1
8"
NEOPRENE WEATHER STRIP
(CONT) FASTEN W/ SELF
TAPPING SCREWS @ 6" OC
4"
4"
NON-DRIVE THRU
TRENCH EMBED,
SEE SHEET W-501
SLIDING DOOR
FACE OF NEW
PILASTER BEYOND
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
23A1 PADEYE ATTACHMENT DETAIL
SCALE: 6" = 1'-0"
SE707-A1.dwg
2" 2"
STAINLESS STEEL L3x2x1 2 x CONT
(INSTALL AFTER CENTERING
BOLTS HAVE BEEN REMOVED),
SEE DETAIL C3/S-706
SLIDING DOOR
CONC BEAM
8"
PLATE 12"x21 16"x1'-41
2"
PLATE 12"x1"x1'-41 2"
8" Ø CENTERING
BOLT, TYP
4"
BOLT,
TYP
REMOVE CENTERING BOLTS AFTER
DOOR IS PLUMBED & PADEYE HAS
BEEN WELDED TO DOOR CHANNEL
PADEYE, SEE SHEET S-708
4" 1
4"
4"±
PADEYE
LINK PLATE
8"
PADEYE
BASE
A3 PADEYE ATTACHMENT DETAIL
SCALE: 6" = 1'-0"
SE707-A3.dwg
PADEYE, SEE SHEET S-708
1'-0"21 4" 21
4"
GUIDE ANGLE
CHANNEL
VERTICAL
STIFFENER
TAB ANGLE, TYP
(2) 3 8" Ø CENTERING BOLTS
EACH GUIDE ANGLE
PADEYE
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
1111 Brickyard Rd, Suite 103 Salt Lake City, UT 84106 Phone 801-333-7676 Fax 801-333-7677
An ABS Group Company
23A1 PADEYE DETAILS
SCALE: 6" = 1'-0"
SE708-A1.dwg
8"
1'-4"
32"
16"
5"
10" 1"
2"
WELDMENT
NOTES:
1. FINISH: ABRASIVE BLAST AND PROTECT
AGAINST CORROSION UNTIL NEXT
WELDED ASSEMBLY.
2. REMOVE BURRS & BREAK SHARP
EDGES FINGER SAFE.
3. ALTERNATE PADEYE CONFIGURATIONS
MAY BE PROPOSED BY DOOR
MANUFACTURER BASED ON APPROVAL.
LINK PLATE DETAIL
8"X 45° ALL
AROUND
WELD PREP
BASE DETAIL
ISOMETRIC
8"
5"
EXTERIOR
SIDE OF PLATE
INTERIOR
SIDE OF PLATE
PADEYE
LINK PLATE
PADEYE
BASE
NOTE:
CONCRETE FILLED DOORS
REQUIRE LINK PLATE OFFSET 18"
NOMINAL TOWARD THE INTERIOR
SIDE OF THE DOOR IN ORDER FOR
DOOR TO HANG PLUMB WHEN BASE
IS CENTERED. VERIFY CENTER OF
GRAVITY OF DOOR PRIOR TO FINAL
PADEYE CONSTRUCTION.
THIS DRAWING HAS BEEN PREPARED BY THE DESIGN PROFESSIONAL
BASED UPON INFORMATION FURNISHED BY THE GOVERNMENT. THE
DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS
NOT RESPONSIBLE FOR THE ACCURACY OF EXISTING DRAWING
INFORMATION OR FOR ANY ERRORS OR OMISSIONS WHICH HAVE BEEN
INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS
DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF
ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE.
SINGLE LINE DIAGRAM SYMBOLS
GROUND
ELECTRICAL PANELBOARD
POWER SYMBOLS
LIGHTING SYMBOLS
MISC SYMBOLS
EXTERIOR LIGHT FIXTURE
DRAWING NOTE
M
1/2 HORESEPOWER MOTOR
MOTOR DISCONNECT SWITCH
HEAT TRACE
HANDHOLE
PULL BOX
DUPLEX RECEPTACLE
NOTE: THIS LEGEND IS COMPOSED OF STANDARD SYMBOLS
AND APPLIES TO THIS SET OF DRAWINGS TO THE
EXTENT APPLICABLE.
GENERAL NOTES APPLY TO ALL ELECTRICAL DRAWINGS:
A. ALL WORK SHALL BE PERFORM ACCORDING TO LATEST NATIONAL
ELECTRICAL CODE AND BY TRAINED AND LICENSED ELECTRICIANS ONLY.
B. EXISTING SITE CONDITION MAY BE DIFFERENT THAN BID PACKAGE.
CONTRACTOR SHALL HAVE SITE VISIT PRIOR TO BIDDING AND SHALL VERIFY
ALL EXISTING CONDITIONS AND REPORT ANY VARIATION FROM BID
PACKAGE TO NAVFAC CONTRACTING OFFICER PRIOR TO BIDDING THE
PROJECT. AFTER CONTRACT IS AWARDED, CONTRACTOR SHALL PROVIDE
ALL SITE SPECIFIC ADAPTATION TO THIS PROJECT WITH OUT ANY
ADDITIONAL COST.
C. THE CONTRACTOR IS EXPECTED TO BE FAMILIAR WITH THE TERMS, LEGEND,
AND ABBREVIATIONS USED IN THE TRADE. IN THE EVENT THAT ANY TERMS,
LEGEND, OR ABBREVIATION USED IN THE SPECIFICATIONS OR ON
DRAWINGS IS NOT CLEAR TO THE CONTRACTOR, HE OR SHE SHOULD
REQUEST CLARIFICATIONS DURING THE BIDDING PERIOD. THE FAILURE TO
UNDERSTAND ANY SUCH TERM, LEGENDS, OR ABBREVIATION SHALL BE
USED AS A BASIS FOR A CHANGE IN CONTRACT COST.
D. LIST OF EQUIPMENT, TABULATIONS OF DATA, SCHEDULES APPEARING IN
THE SPECIFICATIONS OR ON THE DRAWINGS ARE INCLUDED ONLY FOR THE
ASSISTANCE AND GUIDANCE OF THE CONTRACTOR IN ARRIVING AT A MORE
COMPLETE UNDERSTANDING OF THE INTENDED INSTALLATION. THEY ARE
NOT INTENDED, NOR TO BE CONSTRUED, AS RELIEVING THE
RESPONSIBILITY OF THE CONTRACTOR IN MAKING HIS OR HER OWN
TAKE-OFF AND PROVIDING ALL REQUIRED WORK.
E. PROVIDE INDIVIDUAL NEUTRAL WITH EACH PHASE CONDUCTOR FOR SINGLE
PHASE CIRCUITS.
F. CONNECT ALL EMERGENCY LIGHTING, NIGHT LIGHTING, AND EXIT SIGNS
AHEAD OF LOCAL LIGHTING CONTROL TO THE CIRCUIT SERVING THE AREA.
G. PROVIDE GROUNDING TYPE INSULATING BUSHINGS ON ALL IMC AND RGS
CONDUITS ENDS. PROVIDE INSULATED THROUGHOUT FOR ALL EMT
CONDUIT OPENINGS. PROVIDE MINIMUM #6 JUMPER CONNECTION FROM
GROUNDING TERMINAL IN EACH BOX AND PANEL TO ALL GROUNDING TYPE
BUSHINGS.
H. COORDINATE ALL ELECTRICAL WORK WITH OTHER TRADES.
I. ALL BRANCH CIRCUITS SHALL BE EQUIPPED WITH GREEN INSULATED
GROUNDING CONDUCTOR.
J. ALL WIRING SHALL BE COPPER. MINIMUM WIRE SIZE SHALL BE #12.
K. ALL EXPOSED CONDUITS SHALL BE RGS AND ALL UNDERGROUND CONDUITS
SHALL BE CONCERT ENCASED SCHEDULE 80 PVC. ALL UNDERGROUND PVC
CONDUITS SHALL BE CONVERTED TO RGS FROM LAST UNDERGROUND BEND
BEFORE COMING ABOVE GRADE. MINIMUM CONDUIT SIZE SHALL BE 3/4 ”.
L. A CONDUIT WALL PENETRATION SHALL BE WITH MINIMUM 1 ” LARGER
SLEEVE AND ANNULAR SPACE BETWEEN SLEEVE AND CONDUIT SHALL BE
FILLED WITH CAULK RATED EQUAL OR HIGHER STRENGTH THAN WALL
CONSTRUCTION.
ABBREVIATIONS
E N
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C I8
Architecture | Engineering | Interiors | Planning
EXTERIOR ELEVATION (DEMOLITION)
THIS DRAWING HAS BEEN PREPARED BY THE DESIGN PROFESSIONAL
BASED UPON INFORMATION FURNISHED BY THE GOVERNMENT. THE
DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS
NOT RESPONSIBLE FOR THE ACCURACY OF EXISTING DRAWING
INFORMATION OR FOR ANY ERRORS OR OMISSIONS WHICH HAVE BEEN
INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS
DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF
ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE.
INTERIOR ELEVATION (DEMOLITION)
DOOR
EXISTING
RECEPTACLE
EXISTING
SECURITY BOX
TO REMAIN
EXISTING
TELEPHONE BOX
TO REMAIN
EXISTING PANEL
TO BE REMOVED
EXISTING 2"
CONDUIT TO BE
REMOVED
DOOR
TO PANEL
INSIDE
3/4" CONDUIT TO HEAT
TRACE TO BE REMOVED
1-1/2" CONDUIT
1/2" CONDUIT TO BE
REMOVED
1/2" CONDUIT TO BE
REMOVED
1" CONDUIT TO BE
REMOVED
1/2" CONDUIT
2" CONDUIT
TELEPHONE
BELL
240/120V, 1PH, 3W
50A PANEL WITH 8 POLES
120V, 20A CIRCUIT BREAKER
TELEPHONE OUTLET
COMMUNICATION
PANEL AND
DEVICES
1-1/2" CONDUIT
1-1/2" CONDUIT
2" CONDUIT
2" CONDUIT
TO EXISTING
GROUNDING GRID
FLOOR PLAN (DEMOLITION)
COMMUNICATION
PANEL AND DEVICES
EXISTING LIGHT FIXTURE
TO REMAIN (TYPICAL OF 8)
50A PANEL 'C' TO BE REMOVED
20A 1-POLE, ENCLOSED CIRCUIT BREAKER TO BE REMOVED
TELEPHONE BOX TO BE REMOVED
REMOVE POWER
TO EXISTING HEAT
TRACE CABLE
REMOVE EXISTING
HOMERUN TO PANEL C
EXISTING 2"C.
EXISTING 1"C. TO BE
REMOVED
1-1/2" RGS EXISTING
CONDUIT TO BE REMOVED
EXISTING 1-1/2"
CONDUIT TO REMAIN
TO POWER POLE
EXISTING RECEPTACLE TO BE REMOVED
EXISTING SECURITY POWER PANEL TO BE REMOVED
EXISTING TELEPHONE BOX TO REMAIN
EXISTING SECURITY BOX TO REMAIN
EXISTING
CONDUIT TO BE
REMOVED
DRAWING NOTES
REMOVE TELEPHONE BOX AND REMOVE WIRING TO POINT OF ORIGIN. REMOVE 2 ” CONDUIT CUT OUTSIDE OF
CONSTRUCTION AREA. PROVIDE PULL WIRE. SEE “FLOOR PLAN” ON E-101 FOR PROPOSED WORK.
REMOVE EXISTING ELECTRICAL SERVICE WIRING TO POWER POLE AND REMOVE 1 1/2" CONDUIT TO THE
POINT AS INDICATED SEE "FLOOR PLAN" ON DRAWING E-101 FOR PROPOSED WORK DETAILS.
ITEM SHALL BE REMOVED WITH WIRING, CONDUITS AND ACCESSORIES.
EXISTING ITEM SHALL REMAIN AS IS.
REMOVE EXISTING WIRING TO THE POINT OF ORIGIN AND PROVIDE PULL WIRE. REMOVE EXISTING CONDUIT
OUTSIDE OF CONSTRUCTION LIMIT. SEE “FLOOR PLAN” ON E-101 FOR PROPOSED WORK.
REMOVE CONDUIT OUTSIDE OF CONSTRUCTION AREA AND PULL WIRE CAREFULLY WITHOUT DAMAGING IT.
SEE “FLOOR PLAN” ON E-101 FOR PROPOSED WORK.
REMOVE EXISTING WALL MOUNTED LIGHT FIXTURE. SEE “FLOOR PLAN” FOR REINSTALLATION WORK.
E N
G
IN
E E
R
IN
G A
N D
E X
P E
D
IT
IO
N
A R
Y W
A R
FA
R
E C
E N
TE
R
C O
D E
-C
DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS
NOT RESPONSIBLE FOR THE ACCURACY OF EXISTING DRAWING
INFORMATION OR FOR ANY ERRORS OR OMISSIONS WHICH HAVE BEEN
INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS
DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF
ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE.
1/2
CP
DOOR
OPERATOR
CONTROLLER
A-9
PANEL A
EXISTING 2"C.
EXISTING 1-1/4"C.
EXISTING 2"C.
EXISTING 1/2"C.
NEW 1-1/2" PVC
COATED RGS CONDUIT
EXISTING 1-1/2" PVC
UNDER GROUND CONDUIT
PROVIDE
24" X 24" X 4"
DEEP PULL BOX
EXISTING LIGHT FIXTURE TO REMAIN.
REPLACE EXISTING INCANDESCENT
LAMPS WITH REPLACEMENT 23 WATT
FLUORESCENT LAMPS. CONNECT LIGHTS
TO PANEL A, CIRCUIT 7 (TYPICAL OF 8).
PROVIDE CAD-WELD
CONNECTION BETWEEN
REBARS AS INDICATED
#1/0 GROUNDING
CONDUCTOR TO
EXISTING GROUNDING GRID
REFER TO DETAIL 02 ON SHEET
E-103 FOR ICE AND SNOW
MELTING HEAT TRACE DETAIL
2#12, 1#12 GND IN
" RGS CONDUIT TO
"A" CIRCUIT 9.
GFI RECEPTACLE, PROVIDE POWER FROM
PANEL A, CIRCUIT 8 LOCATED ON
EXTERIOR WALL OF BUILDING.
EXISTING SECURITY
BOX TO REMAIN
EXISTING
TELEPHONE
CONDUIT TO REMAIN
24" X 24" X 4"
DEEP PULL
BOX
FLOOR PLAN
SCALE: 1/8" = 1'-0"
REBAR GROUNDING DETAIL
SCALE: 1/8" = 1'-0"
REFER TO DETAIL
03/E-103 FOR
PROPOSED WORK
BALANCED MAGNETIC SWITCH BY GOVERNMENT. CONTRACTOR
TO PROVIDE
" RGS CONDUIT WITH PULL WIRE TO DOOR
OPERATOR CONTROL PANEL FOR INTERLOCK DOOR OPERATION
WITH LOCK POSITION. CONTRACTOR TO PROVIDE ANOTHER
RGS CONDUIT WITH PULL WIRE FROM BMS TO SECURITY
CONTROL PANEL TO BE USED BY SECURITY CONTRACTOR IN
FUTURE.
DRAWING NOTES
CONNECT MOTORIZED DOOR CONTROLLER TO PANEL “A” WITH 2#12 AWG, & 1#12 AWG GROUND IN 3/4 ” RGS
CONDUIT.
PROVIDE 24”X24”X48” DEEP PULL BOX AT THE EXISTING TELEPHONE CONDUIT AND PROVIDE 2 ” CONDUIT
FROM PULL BOX TO THE PROPOSED CONCRETE WALL AND TERMINATE 12 ” AFG ON THE WALL WITH PULL
WIRE AND END CAP.
RELOCATED EXISTING EXTERIOR LIGHT FIXTURE MOUNT ON THE FACE OF NEW BEAM. EXTEND EXISTING
CIRCUIT AND GROUNDING CONDUCTOR AND MAKE FINAL CONNECTION.
SEE SINGLE LINE DIAGRAM ON DRAWING E-104 FOR COMPLETE SERVICE DETAILS.
GENERAL NOTES
A MAIN FEEDER CONDUIT SHALL BE REROUTED TO OTHER SIDE OF MAGAZINE DOOR AS INDICATED.
REFER TO DETAILS 02 AND 04 ON E-103 FOR SNOW AND ICE MELTING HEAT TRACE.
CONTRACTOR SHALL PERFORM COMPLETE SITE INVESTIGATION AND REPORT ANY DISCREPANCIES WITH
CONTRACT DOCUMENTS TO THE CONTRACTING OFFICER. CONTRACTOR IS RESPONSIBLE TO PROVIDE
COMPLETE OPERATIONAL…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .