This document provides a pre-solicitation notice for Facilities Support Services solicitation N40080-18-R-0316 for various locations within the Naval District of Washington. The proposed contract will be a single award Indefinite Delivery Indefinite Quantity performance-based contract comprised of recurring and non-recurring work items including facility management, utilities, and transportation services. The solicitation utilizes FAR Part 15 procedures and will require offerors to submit experience, technical approach, management approach, safety, and past performance, along with price. The tradeoff process will select the offer providing the best value to the government. The NAICS code is 561210 with a small business size standard of $38.5 million. This contract includes a base period of up to 12 months and four 12-month option periods not to exceed 66 months total. The incumbent is currently performing under contract N40080-17-D-0303 with an estimated annual value of $15 million. The final RFP is anticipated on or about August 30, 2018 with proposals due on or about October 14, 2018. This procurement will be solicited as an 8(a) set-aside.
N4008018R0316_J-1502000-06_FIREPROTECTIONSYSTEMSINVENTORY.xlsx
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DAHLGREN FP
| ATTACHMENT J-1502000-05 FPS ASSET INVENTORY | |||||||||||||||||||||||||||||||
| Name | Asset | Changed Date | Description | Long Description | Master System | System | Sub-System | Location | Customer | Site | Work Center | Asset Type | Quantity | Inventory Category | Purchase Price | Budgeted Cost | Replacement Cost | Meter Group | Contract Number | Task/Delivery Order Number | Drawing Ref ID | Status Date | Installation Date | Status | Class Structure ID | Job Plan Code | Equipment Tag ID | Additional Loc Info | |||
| NEW | DL-102-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 10922 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-102 | NSWC | 10101 | WCSPFD | CIMU | Operating | GEM | ||||||||||||||||||
| NEW | DL-102-FPS-02A | 12/15/2016 | D4010370 - DELUGE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010370 - DELUGE SYSTEMS | DAHLGR-102 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-102-FP-01A | 12/15/2016 | D4010905 - FIRE PUMP, ELECTRIC MOTOR DRIVEN | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010905 - FIRE PUMP, ELECTRIC | |||||||||||||||||||||||||
| MOTOR DRIVEN | DAHLGR-102 | NSWC | 10101 | WCSPFD | CIMU | Operating | ITT | ||||||||||||||||||||||||
| NEW | DL-103-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 2333 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-103 | NSWC | 10101 | WCSPFD | CIMU | Operating | UNIQUE | ||||||||||||||||||
| NEW | DL-105-FPS-01A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS, Approximately 6704 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-105 | NDW | 10101 | WCSPFD | CIMU | Operating | NIBCO | ||||||||||||||||||
| NEW | DL-106-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 2611 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-106 | NDW | 10101 | WCSPFD | CIMU | Operating | VIKING | ||||||||||||||||||
| NEW | DL-109-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 8120 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-109 | NDW | 10101 | WCSPFD | CIMU | Operating | RASCO | ||||||||||||||||||
| NEW | DL-1101-FPS-01A | 12/15/2016 | D4010370 - DELUGE SYSTEMS, Apporximately 1022 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010370 - DELUGE SYSTEMS | DAHLGR-1101 | NSWC | 10101 | WCSPFD | CIMU | Operating | RELIABLE | ||||||||||||||||||
| NEW | DL-111-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 17561 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-111 | NSWC | 10101 | WCSPFD | CIMU | Operating | VIKING | ||||||||||||||||||
| NEW | DL-111-FPS-02A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-111 | NSWC | 10101 | WCSPFD | CIMU | Operating | VIKING | ||||||||||||||||||
| NEW | DL-1120-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 4985 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1120 | NSWC | 10101 | WCSPFD | CIMU | Operating | SHOTGUN | ||||||||||||||||||
| NEW | DL-1121-FPS-01A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS, Approximately 10255 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-1121 | NAVFAC | 10101 | WCSPFD | CIMU | Operating | GEM | ||||||||||||||||||
| NEW | DL-1122-FPS-01A | 12/15/2016 | D4010370 - DELUGE SYSTEMS, Apporximately 1200 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010370 - DELUGE SYSTEMS | DAHLGR-1122 | NSWC | 10101 | WCSPFD | CIMU | Operating | EATON | ||||||||||||||||||
| NEW | DL-113-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 28891 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-113 | NSWC | 10101 | WCSPFD | CIMU | Operating | |||||||||||||||||||
| NEW | DL-114-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 1612 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-114 | NAVFAC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-115-FPS-01A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS, Approximately 4493 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-115 | NSWC | 10101 | WCSPFD | CIMU | Operating | GEM | ||||||||||||||||||
| NEW | DL-119-FPS-01A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS, Approximately 5685 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-119 | NDW | 10101 | WCSPFD | CIMU | Operating | KENNEDY VALVE | ||||||||||||||||||
| NEW | DL-1200-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 127232 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1200 | NSWC | 10101 | WCSPFD | CIMU | Operating | SHOTGUN | ||||||||||||||||||
| NEW | DL-1200-FPS-02A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-1200 | NSWC | 10101 | WCSPFD | CIMU | Operating | GEM | ||||||||||||||||||
| NEW | DL-1200-FPS-03A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-1200 | NSWC | 10101 | WCSPFD | CIMU | Operating | MULTIMATIC | ||||||||||||||||||
| NEW | DL-1200-FPS-04A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-1200 | NSWC | 10101 | WCSPFD | CIMU | Operating | RELIABLE | ||||||||||||||||||
| NEW | DL-1200-FPS-05A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-1200 | NSWC | 10101 | WCSPFD | CIMU | Operating | STAR SPRINKLER | ||||||||||||||||||
| NEW | DL-1200-FPS-06A | 12/15/2016 | D4090901 - CARBON DIOXIDE EXTINGUISHING SYS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4090901 - CARBON DIOXIDE | |||||||||||||||||||||||||
| EXTINGUISHING SYS | DAHLGR-1200 | NSWC | 10101 | WCSPFD | CIMU | Operating | KIDDE | ||||||||||||||||||||||||
| NEW | DL-1200-FPS-07A | 12/15/2016 | D4090901 - CARBON DIOXIDE EXTINGUISHING SYS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4090901 - CARBON DIOXIDE | |||||||||||||||||||||||||
| EXTINGUISHING SYS | DAHLGR-1200 | NSWC | 10101 | WCSPFD | CIMU | Operating | KIDDE | ||||||||||||||||||||||||
| NEW | DL-120M-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 10305 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-120M | NAVFAC | 10101 | WCSPFD | CIMU | Operating | GLOBE | ||||||||||||||||||
| NEW | DL-120M-FPS-02A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-120M | NAVFAC | 10101 | WCSPFD | CIMU | Operating | GLOBE | ||||||||||||||||||
| NEW | DL-121-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 14050 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-121 | NSWC | 10101 | WCSPFD | CIMU | Operating | CENTRAL SPRINKLER | ||||||||||||||||||
| NEW | DL-135-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 11729 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-135 | NDW | 10101 | WCSPFD | CIMU | Operating | VIKING | ||||||||||||||||||
| NEW | DL-1357-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 4072 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1357 | NSWC | 10101 | WCSPFD | CIMU | Operating | GEM | ||||||||||||||||||
| NEW | DL-1405-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 50000 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1405 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-1411-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 5040 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1411 | NSWC | 10101 | WCSPFD | CIMU | Operating | SHOTGUN | ||||||||||||||||||
| NEW | DL-1450A-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 103858 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1450A | JWAC | 10101 | WCSPFD | CIMU | Operating | RELIABLE | ||||||||||||||||||
| NEW | DL-1450B-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1450B | JWAC | 10101 | WCSPFD | CIMU | Operating | RELIABLE | ||||||||||||||||||
| NEW | DL-1450B-FPS-02A | 12/15/2016 | D4010370 - DELUGE SYSTEMS, #1 | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010370 - DELUGE SYSTEMS | DAHLGR-1450B | JWAC | 10101 | WCSPFD | CIMU | Operating | RELIABLE | ||||||||||||||||||
| NEW | DL-1450B-FPS-03A | 12/15/2016 | D4010370 - DELUGE SYSTEMS, #2 | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010370 - DELUGE SYSTEMS | DAHLGR-1450B | JWAC | 10101 | WCSPFD | CIMU | Operating | RELIABLE | ||||||||||||||||||
| NEW | DL-1450B-FPS-04A | 12/15/2016 | D4010370 - DELUGE SYSTEMS, #3 | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010370 - DELUGE SYSTEMS | DAHLGR-1450B | JWAC | 10101 | WCSPFD | CIMU | Operating | RELIABLE | ||||||||||||||||||
| NEW | DL-1450B-FPS-05A | 12/15/2016 | D4010370 - DELUGE SYSTEMS, #4 | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010370 - DELUGE SYSTEMS | DAHLGR-1450B | JWAC | 10101 | WCSPFD | CIMU | Operating | RELIABLE | ||||||||||||||||||
| NEW | DL-1452-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 95562 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1452 | JWAC | 10101 | WCSPFD | CIMU | Operating | SHOTGUN | ||||||||||||||||||
| NEW | DL-1460-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 70039 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1460 | NSWC | 10101 | WCSPFD | CIMU | Operating | SHOTGUN | ||||||||||||||||||
| NEW | DL-1470-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 180208 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1470 | NSWC | 10101 | WCSPFD | CIMU | Operating | CENTRAL SPRINKLER | ||||||||||||||||||
| NEW | DL-1480-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 59026 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1480 | NSWC | 10101 | WCSPFD | CIMU | Operating | VIKING | ||||||||||||||||||
| NEW | DL-1490-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1490 | NSWC | 10101 | WCSPFD | CIMU | Operating | VITAULIC OF AMERICA | ||||||||||||||||||
| NEW | DL-1490A-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 112195 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1490A | NSWC | 10101 | WCSPFD | CIMU | Operating | CENTRAL SPRINKLER | ||||||||||||||||||
| NEW | DL-1490B-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1490B | NSWC | 10101 | WCSPFD | CIMU | Operating | RASCO | ||||||||||||||||||
| NEW | DL-150-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 55528 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-150 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-150-FPS-02A | 12/15/2016 | D4010370 - DELUGE SYSTEMS, #1 | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010370 - DELUGE SYSTEMS | DAHLGR-150 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-150-FPS-03A | 12/15/2016 | D4010370 - DELUGE SYSTEMS, #2 | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010370 - DELUGE SYSTEMS | DAHLGR-150 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-1500A-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 122102 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1500A | NSWC | 10101 | WCSPFD | CIMU | Operating | RELIABLE | ||||||||||||||||||
| NEW | DL-1500A-FPS-02A | 12/15/2016 | D4090920 - CLEAN AGENT EXTINGUISHING SYSTEM | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4090920 - CLEAN AGENT | |||||||||||||||||||||||||
| EXTINGUISHING SYSTEM | DAHLGR-1500A | NSWC | 10101 | WCSPFD | CIMU | Operating | KIDDE | ||||||||||||||||||||||||
| NEW | DL-1500A-FPS-03A | 12/15/2016 | D4090920 - CLEAN AGENT EXTINGUISHING SYSTEM | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4090920 - CLEAN AGENT | |||||||||||||||||||||||||
| EXTINGUISHING SYSTEM | DAHLGR-1500A | NSWC | 10101 | WCSPFD | CIMU | Operating | KIDDE | ||||||||||||||||||||||||
| NEW | DL-1500A-FPS-04A | 12/15/2016 | D4090920 - CLEAN AGENT EXTINGUISHING SYSTEM | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4090920 - CLEAN AGENT | |||||||||||||||||||||||||
| EXTINGUISHING SYSTEM | DAHLGR-1500A | NSWC | 10101 | WCSPFD | CIMU | Operating | KIDDE | ||||||||||||||||||||||||
| NEW | DL-1500B-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1500B | NSWC | 10101 | WCSPFD | CIMU | Operating | RELIABLE | ||||||||||||||||||
| NEW | DL-1500B-FPS-02A | 12/15/2016 | D4090901 - CARBON DIOXIDE EXTINGUISHING SYS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4090901 - CARBON DIOXIDE | |||||||||||||||||||||||||
| EXTINGUISHING SYS | DAHLGR-1500B | NSWC | 10101 | WCSPFD | CIMU | Operating | KIDDE | ||||||||||||||||||||||||
| NEW | DL-1500C-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1500C | NSWC | 10101 | WCSPFD | CIMU | Operating | RELIABLE | ||||||||||||||||||
| NEW | DL-1500C-FPS-02A | 12/15/2016 | D4090901 - CARBON DIOXIDE EXTINGUISHING SYS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4090901 - CARBON DIOXIDE | |||||||||||||||||||||||||
| EXTINGUISHING SYS | DAHLGR-1500C | NSWC | 10101 | WCSPFD | CIMU | Operating | KIDDE | ||||||||||||||||||||||||
| NEW | DL-1500C-FPS-03A | 12/15/2016 | D4090901 - CARBON DIOXIDE EXTINGUISHING SYS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4090901 - CARBON DIOXIDE | |||||||||||||||||||||||||
| EXTINGUISHING SYS | DAHLGR-1500C | NSWC | 10101 | WCSPFD | CIMU | Operating | KIDDE | ||||||||||||||||||||||||
| NEW | DL-1500C-FPS-04A | 12/15/2016 | D4090901 - CARBON DIOXIDE EXTINGUISHING SYS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4090901 - CARBON DIOXIDE | |||||||||||||||||||||||||
| EXTINGUISHING SYS | DAHLGR-1500C | NSWC | 10101 | WCSPFD | CIMU | Operating | KIDDE | ||||||||||||||||||||||||
| NEW | DL-1510A-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 62169 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1510A | NSWC | 10101 | WCSPFD | CIMU | Operating | VIKING | ||||||||||||||||||
| NEW | DL-1510B-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1510B | NSWC | 10101 | WCSPFD | CIMU | Operating | RELIABLE | ||||||||||||||||||
| NEW | DL-1510C-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1510C | NSWC | 10101 | WCSPFD | CIMU | Operating | FIREMATIC | ||||||||||||||||||
| NEW | DL-1520A-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 179042 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1520A | NDW | 10101 | WCSPFD | CIMU | Operating | STAR SPRINKLER | ||||||||||||||||||
| NEW | DL-1520B-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1520B | NDW | 10101 | WCSPFD | CIMU | Operating | GEM | ||||||||||||||||||
| NEW | DL-1520C-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1520C | NDW | 10101 | WCSPFD | CIMU | Operating | RELIABLE | ||||||||||||||||||
| NEW | DL-1520C-FP-01A | 12/15/2016 | D4010905 - FIRE PUMP, ELECTRIC MOTOR DRIVEN | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010905 - FIRE PUMP, ELECTRIC | |||||||||||||||||||||||||
| MOTOR DRIVEN | DAHLGR-1520C | NDW | 10101 | WCSPFD | CIMU | Operating | ITT | ||||||||||||||||||||||||
| NEW | DL-1530-FPS--01A | 12/15/2016 | D4010350 - PREACTION SYSTEMS, WET, Approximately 57060 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010350 - PREACTION SYSTEMS | DAHLGR-1530 | NSWC | 10101 | WCSPFD | CIMU | Operating | VIKING | ||||||||||||||||||
| NEW | DL-1530-FPS--02A | 12/15/2016 | D4090920 - CLEAN AGENT EXTINGUISHING SYSTEM | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4090920 - CLEAN AGENT | DAHLGR-1530 | NSWC | 10101 | WCSPFD | CIMU | Operating | FIKE | ||||||||||||||||||
| NEW | DL-1530-FPS-03A | 12/15/2016 | D4090920 - CLEAN AGENT EXTINGUISHING SYSTEM | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4090920 - CLEAN AGENT | DAHLGR-1530 | NSWC | 10101 | WCSPFD | CIMU | Operating | FIKE | ||||||||||||||||||
| NEW | DL-155-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 11092 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-155 | NAVFAC | 10101 | WCSPFD | CIMU | Operating | RASCO | ||||||||||||||||||
| NEW | DL-1560-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 36131 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1560 | NSWC | 10101 | WCSPFD | CIMU | Operating | RELIABLE | ||||||||||||||||||
| NEW | DL-1560-FP-01A | 12/15/2016 | D4010905 - FIRE PUMP, ELECTRIC MOTOR DRIVEN | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010905 - FIRE PUMP, ELECTRIC | |||||||||||||||||||||||||
| MOTOR DRIVEN | DAHLGR-1560 | NSWC | 10101 | WCSPFD | CIMU | Operating | PATTERSON | ||||||||||||||||||||||||
| NEW | DL-1580-FP-01A | 12/15/2016 | D4010905 - FIRE PUMP, ELECTRIC MOTOR DRIVEN | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010905 - FIRE PUMP, ELECTRIC | |||||||||||||||||||||||||
| MOTOR DRIVEN | DAHLGR-1580 | NSWC | 10101 | WCSPFD | CIMU | Operating | STERLING | ||||||||||||||||||||||||
| NEW | DL-1580A-FPS-01A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS, Approximately 58913 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-1580A | NSWC | 10101 | WCSPFD | CIMU | Operating | STOCKHAM VALVES | ||||||||||||||||||
| NEW | DL-1580B-FPS-02A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1580B | NSWC | 10101 | WCSPFD | CIMU | Operating | RELIABLE | ||||||||||||||||||
| NEW | DL-1580C-FPS-03A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1580C | NSWC | 10101 | WCSPFD | CIMU | Operating | SHOTGUN | ||||||||||||||||||
| NEW | DL-1580C-FPS-04A | 12/15/2016 | D4010370 - DELUGE SYSTEMS, #1 | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-1580C | NSWC | 10101 | WCSPFD | CIMU | Operating | SHOTGUN | ||||||||||||||||||
| NEW | DL-1580C-FPS-05A | 12/15/2016 | D4010370 - DELUGE SYSTEMS, #2 | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-1580C | NSWC | 10101 | WCSPFD | CIMU | Operating | SHOTGUN | ||||||||||||||||||
| NEW | DL-1580C-FPS-06A | 12/15/2016 | D4010370 - DELUGE SYSTEMS, #3 | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-1580C | NSWC | 10101 | WCSPFD | CIMU | Operating | SHOTGUN | ||||||||||||||||||
| NEW | DL161-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 4055 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-161 | NSWC | 10101 | WCSPFD | CIMU | Operating | UNIQUE | ||||||||||||||||||
| NEW | DL-1700-FPS-01A | 12/15/2016 | D4010310 - WET PIPE SYSTEMS, Approximately 61129 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1700 | NSWC | 10101 | WCSPFD | CIMU | Operating | CENTRAL SPRINKLER | ||||||||||||||||||
| NEW | DL-1700-FP-01A | 12/15/2016 | D4010905 - FIRE PUMP, ELECTRIC MOTOR DRIVEN | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010905 - FIRE PUMP, ELECTRIC | |||||||||||||||||||||||||
| MOTOR DRIVEN | DAHLGR-1700 | NSWC | 10101 | WCSPFD | CIMU | Operating | ITT | ||||||||||||||||||||||||
| NEW | DL-1701-FPS-01A | 12/15/2016 | D4010310 - WET PIPE SYSTEMS, Approximately 800 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1701 | MDA | 10101 | WCSPFD | CIMU | Operating | CENTRAL SPRINKLER | ||||||||||||||||||
| NEW | DL-1705-FPS-01A | 12/15/2016 | D4010310 - WET PIPE SYSTEMS, Approximately 75166 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-1705 | MDA | 10101 | WCSPFD | CIMU | Operating | WELBEND | ||||||||||||||||||
| NEW | DL-180-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 33098 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-180 | NSWC | 10101 | WCSPFD | CIMU | Operating | GEM | ||||||||||||||||||
| NEW | DL-182A-FPS-01A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS, Approximately 35781 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-182A | NDW | 10101 | WCSPFD | CIMU | Operating | GEM | ||||||||||||||||||
| NEW | DL-182B-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-182B | NDW | 10101 | WCSPFD | CIMU | Operating | RELIABLE | ||||||||||||||||||
| NEW | DL-183-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 53555 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-183 | NSWC | 10101 | WCSPFD | CIMU | Operating | SHOTGUN | ||||||||||||||||||
| NEW | DL-183-FP-01A | 12/15/2016 | D4010905 - FIRE PUMP, ELECTRIC MOTOR DRIVEN | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010905 - FIRE PUMP, ELECTRIC | |||||||||||||||||||||||||
| MOTOR DRIVEN | DAHLGR-183 | NSWC | 10101 | WCSPFD | CIMU | Operating | PATTERSON | ||||||||||||||||||||||||
| NEW | DL-189-FPS-01A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS, Approximately 13392 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-189 | BUMED | 10101 | WCSPFD | CIMU | Operating | GEM | ||||||||||||||||||
| NEW | DL-190-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 10097 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-190 | NSWC | 10101 | WCSPFD | CIMU | Operating | GLOBE | ||||||||||||||||||
| NEW | DL-192-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 17485 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-192 | BUMED | 10101 | WCSPFD | CIMU | Operating | CENTRAL SPRINKLER | ||||||||||||||||||
| NEW | DL-192-FPS-02A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-192 | BUMED | 10101 | WCSPFD | CIMU | Operating | CENTRAL SPRINKLER | ||||||||||||||||||
| NEW | DL-192-FP-01A | 12/15/2016 | D4010905 - FIRE PUMP, ELECTRIC MOTOR DRIVEN | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010905 - FIRE PUMP, ELECTRIC | |||||||||||||||||||||||||
| MOTOR DRIVEN | DAHLGR-192 | BUMED | 10101 | WCSPFD | CIMU | Operating | ITT | ||||||||||||||||||||||||
| NEW | DL-194-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 60138 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-194 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-194-FPS-02A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-194 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-194-FPS-03A | 12/15/2016 | D4010370 - DELUGE SYSTEMS, #1 | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010370 - DELUGE SYSTEMS | DAHLGR-194 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-194-FPS-04A | 12/15/2016 | D4010370 - DELUGE SYSTEMS, #2 | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010370 - DELUGE SYSTEMS | DAHLGR-194 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-194-FPS-05A | 12/15/2016 | D4010370 - DELUGE SYSTEMS, #3 | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010370 - DELUGE SYSTEMS | DAHLGR-194 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-194-FPS-06A | 12/15/2016 | D4010370 - DELUGE SYSTEMS, #4 | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010370 - DELUGE SYSTEMS | DAHLGR-194 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-194-FPS-07A | 12/15/2016 | D4010370 - DELUGE SYSTEMS, #5 | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010370 - DELUGE SYSTEMS | DAHLGR-194 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-194-FPS-08A | 12/15/2016 | D4010370 - DELUGE SYSTEMS, #6 | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010370 - DELUGE SYSTEMS | DAHLGR-194 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-194-FPS-09A | 12/15/2016 | D4010370 - DELUGE SYSTEMS, #7 | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010370 - DELUGE SYSTEMS | DAHLGR-194 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-194-FPS-010A | 12/15/2016 | D4010370 - DELUGE SYSTEMS, #8 | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010370 - DELUGE SYSTEMS | DAHLGR-194 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-198-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 14254 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-198 | NSWC | 10101 | WCSPFD | CIMU | Operating | GEM | ||||||||||||||||||
| NEW | DL-198-FPS-02A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-198 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-200-FPS-01A | 12/15/2016 | D4010370 - DELUGE SYSTEMS, Apporximately 24810 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010370 - DELUGE SYSTEMS | DAHLGR-200 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-207-FPS-01A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS, Approximately 890 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-207 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-212-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 7692 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-212 | NDW | 10101 | WCSPFD | CIMU | Operating | RASCO | ||||||||||||||||||
| NEW | DL-213-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 20079 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-213 | NSWC | 10101 | WCSPFD | CIMU | Operating | VIKING | ||||||||||||||||||
| NEW | DL-215-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 7150 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-215 | NDW | 10101 | WCSPFD | CIMU | Operating | RELIABLE | ||||||||||||||||||
| NEW | DL-216-FPS-01A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS, Approximately 14315 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-216 | NSWC | 10101 | WCSPFD | CIMU | Operating | NIBCO | ||||||||||||||||||
| NEW | DL-218B-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 49242 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-218B | NSWC | 10101 | WCSPFD | CIMU | Operating | GLOBE | ||||||||||||||||||
| NEW | DL-218B-FPS-O2A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-218B | NSWC | 10101 | WCSPFD | CIMU | Operating | VITAULIC OF AMERICA | ||||||||||||||||||
| NEW | DL-218B-FPS-O3A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-218B | NSWC | 10101 | WCSPFD | CIMU | Operating | VITAULIC OF AMERICA | ||||||||||||||||||
| NEW | DL-221-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 39634 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-221 | NSWC | 10101 | WCSPFD | CIMU | Operating | RELIABLE | ||||||||||||||||||
| NEW | DL-221-FPS-02A | 12/15/2016 | D4010370 - DELUGE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010370 - DELUGE SYSTEMS | DAHLGR-221 | NSWC | 10101 | WCSPFD | CIMU | Operating | RELIABLE | ||||||||||||||||||
| NEW | DL-221-FPS-03A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-221 | NSWC | 10101 | WCSPFD | CIMU | Operating | RELIABLE | ||||||||||||||||||
| NEW | DL-221-FPS-04A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-221 | NSWC | 10101 | WCSPFD | CIMU | Operating | RELIABLE | ||||||||||||||||||
| NEW | DL-235-FPS-01A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS, Approximately 6335 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-235 | NSWC | 10101 | WCSPFD | CIMU | Operating | CENTRAL SPRINKLER | ||||||||||||||||||
| NEW | DL-236-FPS-01A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS, Approximately 2973 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-236 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-338-FPS-01A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS, Approximately 4304 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-338 | NDW | 10101 | WCSPFD | CIMU | Operating | GEM | ||||||||||||||||||
| NEW | DL-341-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 1008 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-341 | NDW | 10101 | WCSPFD | CIMU | Operating | VITAULIC OF AMERICA | ||||||||||||||||||
| NEW | DL-411-FPS-01A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS, Approximately 8364 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-411 | NDW | 10101 | WCSPFD | CIMU | Operating | KENNEDY VALVE | ||||||||||||||||||
| NEW | DL-424-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 2044 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-424 | NSWC | 10101 | WCSPFD | CIMU | Operating | KENNEDY VALVE | ||||||||||||||||||
| NEW | DL-437-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 12985 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-437 | NDW | 10101 | WCSPFD | CIMU | Operating | SHOTGUN | ||||||||||||||||||
| NEW | DL-455-FPS-01A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS, Approximately 10255 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-455 | NSWC | 10101 | WCSPFD | CIMU | Operating | GEM | ||||||||||||||||||
| NEW | DL-455-FPS-02A | 12/15/2016 | D4010370 - DELUGE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010370 - DELUGE SYSTEMS | DAHLGR-455 | NSWC | 10101 | WCSPFD | CIMU | Operating | GEM | ||||||||||||||||||
| NEW | DL-470-FPS-01A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS, Approximately 4692 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-470 | NDW | 10101 | WCSPFD | CIMU | Operating | GEM | ||||||||||||||||||
| NEW | DL-470-FPS-02A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-470 | NDW | 10101 | WCSPFD | CIMU | Operating | GEM | ||||||||||||||||||
| NEW | DL-481-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 10952 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-481 | NAVFAC | 10101 | WCSPFD | CIMU | Operating | CENTRAL SPRINKLER | ||||||||||||||||||
| NEW | DL-492-FPS-01A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS, Approximately 5238 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-492 | NSWC | 10101 | WCSPFD | CIMU | Operating | GEM | ||||||||||||||||||
| NEW | DL943-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 10952 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-943 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-948-FPS-01A | 12/15/2016 | D4010370 - DELUGE SYSTEMS, Apporximately 1173 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010370 - DELUGE SYSTEMS | DAHLGR-948 | NSWC | 10101 | WCSPFD | CIMU | Operating | EATON | ||||||||||||||||||
| NEW | DL-959-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 10952 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-959 | NDW | 10101 | WCSPFD | CIMU | Operating | GEM | ||||||||||||||||||
| NEW | DL-960-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 30036 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-960 | NDW | 10101 | WCSPFD | CIMU | Operating | SHOTGUN | ||||||||||||||||||
| NEW | DL-962-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 79614 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-962 | NDW | 10101 | WCSPFD | CIMU | Operating | VIKING | ||||||||||||||||||
| NEW | DL-963-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 9793 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-963 | NDW | 10101 | WCSPFD | CIMU | Operating | RASCO | ||||||||||||||||||
| NEW | DL-995-FPS-01A | 12/15/2016 | D4010410 - WET PIPE SYSTEMS, Approximately 7261 SF Sprinkled | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010410 - WET PIPE SYSTEMS | DAHLGR-995 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL | ||||||||||||||||||
| NEW | DL-995-FPS-02A | 12/15/2016 | D4010310 - DRY PIPE SYSTEMS | D40 - FIRE PROTECTION | D4010 - SPRINKLERS | D4010310 - DRY PIPE SYSTEMS | DAHLGR-995 | NSWC | 10101 | WCSPFD | CIMU | Operating | GRINNELL |
INDIAN HEAD FP
| Asset | Changed Date | Description | Long Description | Master System | System | Sub-System | Location | Site | Work Center | Asset Type | Quantity | Inventory Category | Purchase Price | Budgeted Cost | Replacement Cost | Meter Group | Parent | Contract Number | Task/Delivery Order Number | Drawing Ref ID | Warranty Expiration Date | Status Date | Installation Date | Status | Class Structure ID | Job Plan Code | Equipment Tag ID | Additional Loc Info | Manufacturer | Model | Serial | |
| IH902-FPS- 01-A | Hood Fire Protection-Chemical System Wet Chemical, 3 Gal tank | Fire Hood Protection System #1 | D40-Fire Protection | D4090 - Other fire Protection Systems | D4090902 - Hood Fire Protection | NSWCIH- 902 | WCSPFH | Structure Centralized | 1 | RPIE | Operating | B-902 System #1 - Serving Line | Ansul | R-102 | S322228 | |||||||||||||||||
| IH902-FPS- 01-B | Hood Fire Protection-Chemical System Wet Chemical, 6 Gal tank | Fire Hood Protection System #2 | D40-Fire Protection | D4090 - Other fire Protection Systems | D4090902 - Hood Fire Protection | NSWCIH- 902 | WCSPFH | Structure Centralized | 1 | RPIE | Operating | B-902 System #1 - Serving Line | Ansul | R-102 | S321886 | |||||||||||||||||
| IH1901-FPS- 01-C | Hood Fire Protection-Chemical System Wet Chemical, 3 Gal tank | Fire Hood Protection | D40-Fire Protection | D4090 - Other fire Protection Systems | D4090902 - Hood Fire Protection | NSWCIH- 1901 | WCSPFH | Structure Centralized | 1 | RPIE | Operating | CHILD DEVELOPME | ||||||||||||||||||||
| NT CENTER Kitchen | Ansul | 416218 | ||||||||||||||||||||||||||||||
| IHD323-FPS- 01-D | Hood Fire Protection-Chemical System (Halon System) | Fire Hood Protection | D40-Fire Protection | D4090 - Other fire Protection Systems | D4090902 - Hood Fire Protection | NSWCIH- D323 | WCSPFH | Structure Centralized | 1 | RPIE | Operating | D-323 Basement SKIF Room | Kidde | Sensiscan 10000 | ||||||||||||||||||
| IH878-FPS- 01-E | Hood Fire Protection-Chemical System Wet Chemical, 1.25 Gal tank | Fire Hood Protection Hood "A" | D40-Fire Protection | D4090 - Other fire Protection Systems | D4090902 - Hood Fire Protection | NSWCIH- 878 | WCSPFH | Structure Centralized | 1 | RPIE | Operating | B-878 Fire House Hood System "A" | Guardian III | G300A | ||||||||||||||||||
| IH878-FPS- 01-F | Hood Fire Protection-Chemical System Wet Chemical, 1.25 Gal tank | Fire Hood Protection Hood"B" | D40-Fire Protection | D4090 - Other fire Protection Systems | D4090902 - Hood Fire Protection | NSWCIH- 878 | WCSPFH | Structure Centralized | 1 | RPIE | Operating | B-878 Fire House Hood System "B" | Guardian III | G300A | ||||||||||||||||||
| IH620-FPS- 01-G | Hood Fire Protection-Chemical System Wet Chemical, 2.6 Gal tank | Fire Hood Protection | D40-Fire Protection | D4090 - Other fire Protection Systems | D4090902 - Hood Fire Protection | NSWCIH- 620 | WCSPFH | Structure Centralized | 1 | RPIE | Operating | B-620 Café Pizza Area | Kidde | Range Guard B120010 | ||||||||||||||||||
| IH620-FPS- 01-H | Hood Fire Protection-Chemical System Wet Chemical, 4 Gal tank | Fire Hood Protection | D40-Fire Protection | D4090 - Other fire Protection Systems | D4090902 - Hood Fire Protection | NSWCIH- 620 | WCSPFH | Structure Centralized | 1 | RPIE | Operating | B-620 Cafe Fry Station | Kidde | Range Guard B120010 | ||||||||||||||||||
| IHD28-FPS-01-I | Hood Fire Protection-Chemical System Wet Chemical, 1.5 Gal tank | Fire Hood Protection | D40-Fire Protection | D4090 - Other fire Protection Systems | D4090902 - Hood Fire Protection | NSWCIH-D28 | WCSPFH | Structure Centralized | 1 | RPIE | Operating | |||||||||||||||||||||
| IH551-FPS-014-J | Hood Fire Protection-Chemical System Wet Chemical, 1.5 Gal tank | Fire Hood Protection | D40-Fire Protection | D4090 - Other fire Protection Systems | D4090902 - Hood Fire Protection | NSWCIH-551 | WCSPFH | Structure Centralized | 1 | RPIE | Operating |
JBAB FP
| EQUIPMENT NUMBER | SITE | LOCATION | FACILITY NUMBER | EQUIPMENT TYPE | EQUIPMENT DESCRIPTION | MISC INFO | MANUFACTURER | MODEL | SERIAL # | LOCATION IN BUILDING | CUSTOMER | |
| JBAB | BOL | 3610 | FIRE SUPPRESSION | ANSUL LIQUID AGENT FIRE | ||||||||
| SUPPRESSION SYSTEM | ANSUL | R-102 | KITCHEN | J-9 | ||||||||
| JBAB | BOL | 4455 | FIRE SUPPRESSION | ANSUL LIQUID AGENT FIRE SUPPRESSION SYSTEM | ANSUL | R-102 | KITCHEN | CNIC | ||||
| JBAB | BOL | 4456 | FIRE SUPPRESSION | ANSUL LIQUID AGENT FIRE SUPPRESSION SYSTEM | ANSUL | R-102 | KITCHEN | CNIC | ||||
| JBAB | BOL | 50 | FIRE SUPPRESSION | ANSUL LIQUID AGENT FIRE SUPPRESSION SYSTEM | ANSUL | 1ST FLOOR KITCHEN | J-9 | |||||
| JBAB | BOL | 50 | FIRE SUPPRESSION | ANSUL LIQUID AGENT FIRE SUPPRESSION SYSTEM | ANSUL | 1ST FLOOR KITCHEN | J-9 | |||||
| JBAB | BOL | 50 | FIRE SUPPRESSION | ANSUL LIQUID AGENT FIRE SUPPRESSION SYSTEM | ANSUL | 2ND FLOOR KITCHEN | J-9 | |||||
| JBAB | BOL | 1310 | FIRE SUPPRESSION | ANSUL LIQUID AGENT FIRE SUPPRESSION SYSTEM | ANSUL | KITCHEN | J-9 | |||||
| JBAB | BOL | 2482 | FIRE SUPPRESSION | ANSUL LIQUID AGENT FIRE SUPPRESSION SYSTEM | ANSUL | KITCHEN | J-9 | |||||
| JBAB | BOL | 4500 | FIRE SUPPRESSION | ANSUL LIQUID AGENT FIRE SUPPRESSION SYSTEM | ANSUL | KITCHEN | AAFES | |||||
| JBAB | BOL | 4514 | FIRE SUPPRESSION | ANSUL LIQUID AGENT FIRE SUPPRESSION SYSTEM | ANSUL | FOOD COURT | AAFES | |||||
| JBAB | BOL | 4514 | FIRE SUPPRESSION | ANSUL LIQUID AGENT FIRE SUPPRESSION SYSTEM | ANSUL | FOOD COURT | AAFES | |||||
| JBAB | BOL | 4514 | FIRE SUPPRESSION | ANSUL LIQUID AGENT FIRE SUPPRESSION SYSTEM | ANSUL | FOOD COURT | AAFES | |||||
| JBAB | BOL | 4514 | FIRE SUPPRESSION | ANSUL LIQUID AGENT FIRE SUPPRESSION SYSTEM | ANSUL | FOOD COURT | AAFES | |||||
| JBAB | BOL | 4514 | FIRE SUPPRESSION | ANSUL LIQUID AGENT FIRE SUPPRESSION SYSTEM | ANSUL | FOOD COURT | AAFES | |||||
| ANA-ACV-B168-1 | JBAB | ANA | 168 | ACV | ACV - ALARM CHECK VALVE | CNIC | ||||||
| ANA-AV-B168-1 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-2 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-3 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-4 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-5 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-6 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-7 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-8 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-9 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-10 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-11 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-12 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-13 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-14 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-15 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-16 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-17 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-18 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-19 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-20 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-21 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-22 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-23 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-24 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-25 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-26 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-27 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-28 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-29 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-30 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-31 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-32 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-33 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-34 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-35 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-36 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-37 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-38 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-39 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-40 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-41 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-42 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-AV-B168-43 | JBAB | ANA | 168 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-CV-B168-1 | JBAB | ANA | 168 | CV | CV - CONTROL VALVE | SECTIONAL OR MAIN | CNIC | |||||
| ANA-CV-B168-2 | JBAB | ANA | 168 | CV | CV - CONTROL VALVE | SECTIONAL OR MAIN | CNIC | |||||
| ANA-CV-B168-3 | JBAB | ANA | 168 | CV | CV - CONTROL VALVE | SECTIONAL OR MAIN | CNIC | |||||
| ANA-CV-B168-4 | JBAB | ANA | 168 | CV | CV - CONTROL VALVE | SECTIONAL OR MAIN | CNIC | |||||
| ANA-FACP-B168-1 | JBAB | ANA | 168 | FACP | FACP - FIRE ALARM CONTROL PANEL | NOTIFIER | AFP200 | CNIC | ||||
| ANA-FARS-B168-1 | JBAB | ANA | 168 | FARS | FARS - FIRE ALARM REPORTING SYSTEM | AES TRANSMITTER SYSTEM | NEW INVENTORY | CNIC | ||||
| ANA-FDC-B168-1 | JBAB | ANA | 168 | FDC | FDC - FIRE DEPARTMENT CONNECTION | CNIC | ||||||
| ANA-PIV-B168-1 | JBAB | ANA | 168 | PIV | PIV - POST INDICATOR VALVE | CNIC | ||||||
| ANA-PS-B168-1 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-2 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-3 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-4 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-5 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-6 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-7 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-8 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-9 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-10 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-11 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-12 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-13 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-14 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-15 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-16 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-17 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-18 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-19 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-20 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-21 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-22 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-23 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-24 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-PS-B168-25 | JBAB | ANA | 168 | PS | PS - MANUAL PULL STATION | CNIC | ||||||
| ANA-RA-B168-1 | JBAB | ANA | 168 | RA | RA - REMOTE ANNUNCIATOR | CNIC | ||||||
| ANA-SD-B168-1 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-2 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-3 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-4 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-5 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-6 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-7 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-8 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-9 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-10 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-11 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-12 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-13 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-14 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-15 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-16 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-17 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-18 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-19 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-20 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-21 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-22 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-23 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-24 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-25 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-26 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-27 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-28 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-29 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-30 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-31 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-32 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-33 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-34 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-35 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-36 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-37 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-38 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-39 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-40 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SD-B168-41 | JBAB | ANA | 168 | SD | SD - AREA SMOKE DETECTOR | CNIC | ||||||
| ANA-SP-B168-1 | JBAB | ANA | 168 | SP | SP - STAND ALONE STAND PIPE SYSTEM | CNIC | ||||||
| ANA-SP-B168-2 | JBAB | ANA | 168 | SP | SP - STAND ALONE STAND PIPE SYSTEM | CNIC | ||||||
| ANA-VN-B168-1 | JBAB | ANA | 168 | VN | VN - VISUAL NOTIFICATION APPLIANCE | CNIC | ||||||
| ANA-VT-B168-1 | JBAB | ANA | 168 | VT | VT - VALVE TAMPER SWITCH | CNIC | ||||||
| ANA-VT-B168-2 | JBAB | ANA | 168 | VT | VT - VALVE TAMPER SWITCH | CNIC | ||||||
| ANA-VT-B168-3 | JBAB | ANA | 168 | VT | VT - VALVE TAMPER SWITCH | CNIC | ||||||
| ANA-VT-B168-4 | JBAB | ANA | 168 | VT | VT - VALVE TAMPER SWITCH | CNIC | ||||||
| ANA-VT-B168-5 | JBAB | ANA | 168 | VT | VT - VALVE TAMPER SWITCH | CNIC | ||||||
| ANA-VT-B168-6 | JBAB | ANA | 168 | VT | VT - VALVE TAMPER SWITCH | CNIC | ||||||
| ANA-VT-B168-7 | JBAB | ANA | 168 | VT | VT - VALVE TAMPER SWITCH | CNIC | ||||||
| ANA-VT-B168-8 | JBAB | ANA | 168 | VT | VT - VALVE TAMPER SWITCH | CNIC | ||||||
| ANA-WET-B168-1 | JBAB | ANA | 168 | WET | WET - WET SPRINKLER SYSTEM | 480 FIRE SPRINKLER HEADS | 59,5000 SQFT, 4 STORIES | CNIC | ||||
| ANA-WF-B168-1 | JBAB | ANA | 168 | WF | WF - WATER FLOW DETECTOR (FLOW OR PRESSURE) | CNIC | ||||||
| ANA-WF-B168-2 | JBAB | ANA | 168 | WF | WF - WATER FLOW DETECTOR (FLOW OR PRESSURE) | CNIC | ||||||
| ANA-WF-B168-3 | JBAB | ANA | 168 | WF | WF - WATER FLOW DETECTOR (FLOW OR PRESSURE) | CNIC | ||||||
| ANA-WF-B168-4 | JBAB | ANA | 168 | WF | WF - WATER FLOW DETECTOR (FLOW OR PRESSURE) | CNIC | ||||||
| ANA-WF-B168-5 | JBAB | ANA | 168 | WF | WF - WATER FLOW DETECTOR (FLOW OR PRESSURE) | CNIC | ||||||
| ANA-WF-B168-6 | JBAB | ANA | 168 | WF | WF - WATER FLOW DETECTOR (FLOW OR PRESSURE) | CNIC | ||||||
| ANA-WF-B168-7 | JBAB | ANA | 168 | WF | WF - WATER FLOW DETECTOR (FLOW OR PRESSURE) | CNIC | ||||||
| ANA-WF-B168-8 | JBAB | ANA | 168 | WF | WF - WATER FLOW DETECTOR (FLOW OR PRESSURE) | CNIC | ||||||
| ANA-WF-B168-9 | JBAB | ANA | 168 | WF | WF - WATER FLOW DETECTOR (FLOW OR PRESSURE) | CNIC | ||||||
| ANA-WF-B168-10 | JBAB | ANA | 168 | WF | WF - WATER FLOW DETECTOR (FLOW OR PRESSURE) | CNIC | ||||||
| ANA-ACV-B350-1 | JBAB | ANA | 350 | ACV | ACV - ALARM CHECK VALVE | DCNG | ||||||
| ANA-AV-B350-1 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-AV-B350-2 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-AV-B350-3 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-AV-B350-4 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-AV-B350-5 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-AV-B350-6 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-AV-B350-7 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-AV-B350-8 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-AV-B350-9 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-AV-B350-10 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-AV-B350-11 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-AV-B350-12 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-AV-B350-13 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-AV-B350-14 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-AV-B350-15 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-AV-B350-16 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-AV-B350-17 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-AV-B350-18 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-AV-B350-19 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-AV-B350-20 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-AV-B350-21 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-AV-B350-22 | JBAB | ANA | 350 | AV | AV - AUDIO VISUAL NOTIFICATION APPLIANCE | DCNG | ||||||
| ANA-CO2-B350-1 | JBAB | ANA | 350 | CO2 | CO2 - CO2 SYSTEM | 75 LB CYLINDERS (4) MAIN, (4) RESERVE, NO SEPARATE RELAY PANEL | KIDDE | COMPUTER ROOM UNDER FLOOR | DCNG | |||
| ANA-CV-B350-1 | JBAB | ANA | 350 | CV | CV - CONTROL VALVE | SECTIONAL OR MAIN | DCNG | |||||
| ANA-DMP-B350-1 | JBAB | ANA | 350 | DMP | DMP - DIALER | DCNG | ||||||
| ANA-DRY-B350-1 | JBAB | ANA | 350 | DRY | DRY - DRY SPRINKLER SYSTEM | INCLUDES DRY PIPE VALVE | 1 STORY | DCNG | ||||
| ANA-FACP-B350-1 | JBAB | ANA | 350 | FACP | FACP - FIRE ALARM CONTROL PANEL | NOTIFIER | AFP200 | DCNG | ||||
| ANA-FARS-B350-1 | JBAB | ANA | 350 | FARS | FARS - FIRE ALARM REPORTING SYSTEM | KING FISHER RTI 20-52 TRANSMITTERS | DCNG | |||||
| ANA-HD-B350-1 | JBAB | ANA | 350 | HD | HD - HEAT DETECTOR | DCNG | ||||||
| ANA-HLA-B350-1 | JBAB | ANA | 350 | HLA | HLA - HIGH LOW AIR PRESSURE SWITCH | DCNG | ||||||
| ANA-PS-B350-1 | JBAB | ANA | 350 | PS | PS - MANUAL PULL STATION | DCNG | ||||||
| ANA-PS-B350-2 | JBAB | ANA | 350 | PS | PS - MANUAL PULL STATION | DCNG | ||||||
| ANA-PS-B350-3 | JBAB | ANA | 350 | PS | PS - MANUAL PULL STATION | DCNG | ||||||
| ANA-PS-B350-4 | JBAB | ANA | 350 | PS | PS - MANUAL PULL STATION | DCNG | ||||||
| ANA-PS-B350-5 | JBAB | ANA | 350 | PS | PS - MANUAL PULL STATION | DCNG | ||||||
| ANA-RA-B350-1 | JBAB | ANA | 350 | RA | RA - REMOTE ANNUNCIATOR | DCNG | ||||||
| ANA-SD-B350-1 | JBAB | ANA | 350 | SD | SD - AREA SMOKE DETECTOR | DCNG | ||||||
| ANA-SD-B350-2 | JBAB | ANA | 350 | SD | SD - AREA SMOKE DETECTOR | DCNG | ||||||
| ANA-SD-B350-3 | JBAB | ANA | 350 | SD | SD - AREA SMOKE DETECTOR | DCNG | ||||||
| ANA-SD-B350-4 | JBAB | ANA | 350 | SD | SD - AREA SMOKE DETECTOR | DCNG |