J-2 NONSKID ELINS ORDERING PERIODS 1 THROUGH 5.xlsx

XLSX spreadsheet 66 KB Posted

Attached to
NONSKID FOR NAVAL SHIPS/VESSELS
Solicitation number
N4002727R0004
Issued by

About this file

This file is a pricing template in Excel format that establishes the Economic Line Item Numbers (ELINs) and ordering periods for the J-2 Nonskid contract under the Naval Sea Systems Command's IDIQ supply contract for nonskid deck covering removal and replacement on U.S. Navy ships and vessels.

The template structures pricing across five ordering periods, with ELINs corresponding to different nonskid application methods and surface preparation standards. Contractors are required to provide unit pricing for nonskid materials and application services that comply with Society for Protective Coatings (SSPC) standards including SSPC-SP10/NACE 2 Near-White Blast Cleaning, SSPC-SP11 Power Tool Cleaning to Bare Metal, and SSPC-SP12 WJ-3/NACE 5 High and Ultra High Pressure Water Jetting. Acceptable nonskid products include MIL-PRF-24667 Type I or Type V roll-on nonskid, Type IV spray-on nonskid, or Type XI peel-and-stick sections. The IDIQ contract vehicle allows for indefinite quantities across the five ordering periods, enabling the Navy to issue task orders for nonskid replacement work as operational requirements dictate. Contractors must complete pricing for all applicable ELINs to enable competitive ordering under this supply contract.

View the file

Other files

File Type Posted
EXHIBIT A DD FORM 1423 2.pdf PDF
Solicitation - N4002727R0004.pdf PDF
S-1 Request for Specification Clarification.docx DOCX document
J-1 NOTIONAL WORK ITEMS.pdf PDF
EXHIBIT A DD FORM 1423 3.pdf PDF
EXHIBIT A DD FORM 1423 4.pdf PDF
EXHIBIT A DD FORM 1423 1.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Ordering Period 1

SECTION B CLIN 0001 - ORDERING PERIOD ONE The Government is not obligated, nor is the Government limited, to the quantities listed below. The quantities listed are for estimating purposes only.
ELINDescriptionUnit of IssueUnit PriceEstimated QtyExtended Amount
0001Remove existing and install new Nonskid in accordance with Work Specification Item 634-11-001 (DDG Class)
0001AARemove existing and install new Nonskid Forecastle Deck, Bow to Frame 126, in accordance with paragraphs 3.1, 3.2, 3.6 and 3.7LOT3$ - 0
0001ABRemove existing and install new Nonskid Flight Deck and RAST Track Plate Tops, Frame 399 to Stern, in accordance with paragraphs 3.1, 3.2, 3.6 and 3.7LOT2$ - 0
0001ACRemove existing and install new Nonskid Flight Deck, Frame 370 to stern, in accordance with paragraphs 3.1, 3.2, 3.6 and 3.7LOT2$ - 0
0001ADRemove existing and install new Nonskid Helicopter Hanger No.1 (1-338-3-Q), including RAST Track Plate Tops, in accordance with paragraphs 3.1, 3.2, 3.6 and 3.7LOT2$ - 0
0001AERemove existing and install new Nonskid Helicopter Hanger No. 2 (1-338-8-Q), including RAST Track Plate Tops, in accordance with paragraphs 3.1, 3.2, 3.6 and 3.7LOT2$ - 0
0001AFRemove existing and install new Nonskid 01 Level, Frame 118 to 207, Port Side Castleway/Passageway (01-118-4-L), in accordance with paragraphs 3.1, 3.3, 3.6 and 3.7LOT3$ - 0
0001AGRemove existing and install new Nonskid 01 Level, Frame 118 to 207, STBD Side Castleway/Passageway (01-118-1-L), in accordance with paragraphs 3.1, 3.3, 3.6 and 3.7LOT3$ - 0
0001AHRemove existing and install new Nonskid 01 Level, Frame 204 to 328, Port and STBD Weatherdeck, in accordance with paragraphs 3.1, 3.3, 3.6 and 3.7LOT3$ - 0
0001AJRemove existing and install new Nonskid 01 Level, Frame 204 to 370, Port and STBD Weatherdeck, in accordance with paragraphs 3.1, 3.3, 3.6 and 3.7LOT2$ - 0
0001AKRemove existing and install new Nonskid 02 Level, Frame 110 to 138, Port and STBD Weatherdeck and RAS Station No. 3 and No. 4, Including Intermediate Platforms, in accordance with paragraphs 3.1, 3.3, 3.6 and 3.7LOT3$ - 0
0001ALRemove existing and install new Nonskid Forward CIWS Magazine (02-112-2-M), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
0001AMRemove existing and install new Nonskid 02 Level, Frame 193 to 228, Port and STBD Weatherdeck, in accordance with paragraphs 3.1, 3.5, 3.6 and 3.7LOT2$ - 0
0001ANRemove existing and install new Nonskid 02 Level, Frame 228 to 237, NUKLA Platform, in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT3$ - 0
0001APRemove existing and install new Nonskid 02 Level, Frame 242 to 312, Port and STBD Weatherdeck, in accordance with paragraphs 3.1, 3.5, 3.6 and 3.7LOT3$ - 0
0001AQRemove existing and install new Nonskid 02 Level, Frame 312 to 396, Port and STBD Weatherdeck, in accordance with paragraphs 3.1, 3.3, 3.6 and 3.7LOT2$ - 0
0001ARRemove existing and install new Nonskid 03 Level, Frame 145 to 193, Port and STBD Weatherdeck, in accordance with paragraphs 3.1, 3.5, 3.6 and 3.7LOT3$ - 0
0001ASRemove existing and install new Nonskid 04 Level, Frame 140 to 176, Port and STBD Weatherdeck, including Bridge Wings and Signal Bridge, in accordance with paragraphs 3.1, 3.5, 3.6 and 3.7LOT3$ - 0
0001ATRemove existing and install new Nonskid 05 Level, Frame 130 to 170, Port and STBD Weatherdeck, in accordance with paragraphs 3.1, 3.5, 3.6 and 3.7LOT3$ - 0
0001AURemove existing and install new Nonskid 06 Level, Frame 137 to 165, Port and STBD Weatherdeck, in accordance with paragraphs 3.1, 3.5, 3.6 and 3.7LOT3$ - 0
0001AVRemove existing and install new Nonskid Weapons & Aviation Ordnance Equipment Workshop (01-300-0-Q), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT3$ - 0
0001AWRemove existing and install new Nonskid Weapons Magazine (01-300-1-M), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
0001AXRemove existing and install new Nonskid AFT CIWS Magazine No.2 (01-300-2-M), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
0001AYRemove existing and install new Nonskid passageway (1-42-01-L), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
0001AZRemove existing and install new Nonskid Torpedo Missile and Rocket Magazine (1-304-2-M), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
0001BARemove existing and install new Nonskid Fixed Gun Ammunition Rocket Magazine (1-318-2-M), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
0001BBRemove existing and install new Nonskid Aviation Repair Shop (1-381-0-Q), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
0001BCRemove existing and install new Nonskid General Workshop (2-200-2-Q), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
0001BDRemove existing and install new Nonskid passageway (2-370-2-L), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
0001BERemove existing and install new Nonskid passageway (2-370-3-L), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
0001BFRemove existing and install new Nonskid passageway (2-370-4-L), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
0001BGRemove existing and install new Nonskid passageway (2-374-2-L), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
0001BHRemove existing and install new Nonskid passageway (2-374-4-L), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
0001BJRemove existing and install new Nonskid passageway (2-410-0-L), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
0001BKRemove existing and install new Nonskid RAST Machinery Room (2-442-0-E), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
0001BLRemove existing and install new Nonskid 5/54 Projectile Magazine (3-42-0-M) in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT1$ - 0
0001BMRemove existing and install new Nonskid 5/54 Powder Magazine No. 1 (3-62-1-M) in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT1$ - 0
0001BNRemove existing and install new Nonskid Powder Magazine No.1 (3-68-1-M), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT1$ - 0
0001BPRemove existing and install new Nonskid, Powder Magazine No. 2 (3-68-2-M), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT1$ - 0
0001BQRemove existing and install new Nonskid as designated by the SUPERVISOR, 1-50 square feet, in accordance with paragraphs 3.1 through 3.7. (As Per Delivery Order)SF50$ - 0
0001BRRemove existing and install new Nonskid as designated by the SUPERVISOR, 51-250 square feet, in accordance with paragraphs 3.1 through 3.7. (As Per Delivery Order)SF500$ - 0
0001BSRemove existing and install new Nonskid as designated by the SUPERVISOR, 251-500 square feet, in accordance with paragraphs 3.1 through 3.7. (As Per Delivery Order)SF2500$ - 0
0002Remove existing and install new Nonskid in accordance with Work Specification Item 634-11-002 (CG Class)
0002AARemove existing and install new Nonskid Forecastle Deck, Bow to Frame 138, in accordance with paragraphs 3.1, 3.2, and 3.7.LOT1$ - 0
0002ABRemove existing and install new Nonskid Main Deck, Frame 454 to Stern, in accordance with paragraphs 3.1, 3.2, and 3.7.LOT1$ - 0
0002ACRemove existing and install new Nonskid Helicopter Hanger 02-292-2-Q, including RAST Track Plate Tops, in accordance with paragraphs 3.1, 3.3, and 3.7.LOT1$ - 0
0002ADRemove existing and install new Nonskid Flight Deck, 02 Level, Frame 346 to 418, including RAST Track Plate Tops, in accordance with paragraphs 3.1, 3.3, and 3.7.LOT1$ - 0
0002AERemove existing and install new Nonskid Port Boat Deck, Frame 270 to 304, in accordance with paragraphs 3.1, 3.5,and 3.7.LOT1$ - 0
0002AFRemove existing and install new Nonskid STBD Boat Deck, Frame 270 to 294, in accordance with paragraphs 3.1, 3.5, and 3.7.LOT1$ - 0
0002AGRemove existing and install new Nonskid Passageway (01-138-2-L), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002AHRemove existing and install new Nonskid Passageway (01-138-3-L), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002AJRemove existing and install new Nonskid 01 Level, Frame 174 to 409, Port Side, in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002AKRemove existing and install new Nonskid 01 Level, Frame 174 to 409, STBD Side, in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002ALRemove existing and install new Nonskid 01 Level, Frame 409 to 472, in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002AMRemove existing and install new Nonskid 04 Level, Frame 174 to 248, in accordance with paragraphs 3.1, 3.5, and 3.7.LOT1$ - 0
0002ANRemove existing and install new Nonskid 04 Level, Frame 289 to 346, in accordance with paragraphs 3.1, 3.5, and 3.7.LOT1$ - 0
0002APRemove existing and install new Nonskid 03 Level, Frame 180 to 289, in accordance with paragraphs 3.1, 3.5, and 3.7.LOT1$ - 0
0002AQRemove existing and install new Nonskid Helicopter Repair Shop (02-276-01-Q), in accordance with paragraphs 3.1, 3.5, and 3.7.LOT1$ - 0
0002ARRemove existing and install new Nonskid RAST Machinery Room (01-382-0-Q), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002ASRemove existing and install new Nonskid Sonobuoy Storeroom (01-398-1-A), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002ATRemove existing and install new Nonskid Windlass Room (1-0-0-E), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002AURemove existing and install new Nonskid 5/54 Loader Drum Room No. 1 (1-58-0-M), in accordance with paragraphs 3.1, 3.4, and 3.7 .LOT1$ - 0
0002AVRemove existing and install new Nonskid Torpedo Room No. 1 (1-390-1-M), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002AWRemove existing and install new Nonskid Torpedo Room No. 2 (1-390-4-M), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002AXRemove existing and install new Nonskid 5/54 Ammo Pallet Staging Room No.1 (2-58-0-Q), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002AYRemove existing and install new Nonskid Reefer Machinery Room (2-220-4-Q), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002AZRemove existing and install new Nonskid Filter Cleaning Shop (2-382-4-Q), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002BARemove existing and install new Nonskid General Workshop (2-387-0-Q), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002BBRemove existing and install new Nonskid Stores Handling Room (2-464-0-A), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002BCRemove existing and install new Nonskid 5/54 Loader Drum Room No. 2 (2-482-0-M), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002BDRemove existing and install new Nonskid 5/54 Projectile Magazine No. 1 (3-62-0-M), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002BERemove existing and install new Nonskid Mk 26 Magazine No. 1 (3-97-01-M), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002BFRemove existing and install new Nonskid Pump Room No. 2 & AC Machinery Room (3-398-0-E), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002BGRemove existing and install new Nonskid Mk 26 Magazine No. 2 (3-435-01-M), in accordance with paragraphs 3.1, 3.4,and 3.7.LOT1$ - 0
0002BHRemove existing and install new Nonskid 5/54 Ammo Pallet Staging Room No. 2 (3-464-0-Q), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002BJRemove existing and install new Nonskid 5/54 Projectile Magazine No. 2 (3-482-0-M), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002BKRemove existing and install new Nonskid 5/54 Powder Magazine No. 3 (3-494-0-M), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
0002BLRemove existing and install new Nonskid as designated by the SUPERVISOR, 1-50 square feet, in accordance with paragraphs 3.1 through 3.7. (As Per Delivery Order)SF50$ - 0
0002BMRemove existing and install new Nonskid as designated by the SUPERVISOR, 51-250 square feet, in accordance with paragraphs 3.1 through 3.7. (As Per Delivery Order)SF500$ - 0
0002BNRemove existing and install new Nonskid as designated by the SUPERVISOR, 251-500 square feet, in accordance with paragraphs 3.1 through 3.7. (As Per Delivery Order)SF2500$ - 0
0003Remove existing and install new Nonskid in accordance with Work Specification Item 634-11-003 (LCS Freedom Class)
0003AARemove existing and install new Nonskid Flight Deck in accordance with paragraphs 3.1, 3.2, 3.9 and 3.10.LOT3$ - 0
0003ABRemove existing and install new Nonskid Airborne Mission Zone (AMZ) in accordance with 3.1, 3.2, 3.9 and 3.10. (roll on nonskid)LOT2$ - 0
0003ACRemove existing and install new Nonskid Airborne Mission Zone (AMZ) in accordance with 3.1, 3.3, 3.9 and 3.10. (spray on nonskid)LOT2$ - 0
0003ADRemove existing and install new Nonskid Forecastle in accordance with 3.1, 3.4, 3.9 and 3.10. (spray on nonskid)LOT2$ - 0
0003AERemove existing and install new Nonskid Forecastle in accordance with 3.1, 3.5, 3.9 and 3.10. roll on nonskid.)LOT2$ - 0
0003AFRemove existing and install new Nonskid Boat Deck and Pway 1-31-4-Q in accordance with 3.1, 3.4, 3.9 and 3.10. spray on nonskid)LOT2$ - 0
0003AGRemove existing and install new Nonskid Boat Deck and Pway 1-31-4-Q in accordance with 3.1, 3.5, 3.3.9 and 3.10. roll on nonskid)LOT2$ - 0
0003AHRemove existing and install new Nonskid Water Borne Mission Zone (WMZ) 3-65-0-Q in accordance with 3.1, 3.4, 3.9 and 3.10. (spray on nonskid)LOT2$ - 0
0003AJRemove existing and install new Nonskid Water Borne Mission Zone (WMZ) 3-65-0-Q in accordance with 3.1 3.5, 3.9 and 3.10. roll on nonskid)LOT3$ - 0
0003AKRemove existing and install new Nonskid Reconfigurable Space 1 (RECON 1) 3-45-0-Q in accordance with 3.1, 3.6, 3.9 and 3.10. (roll on nonskid)LOT2$ - 0
0003ALRemove existing and install new Nonskid Reconfigurable Space 1 (RECON 1) 3-45-0-Q in accordance with 3.1, and 3.7 through 3.9. (peel and stick nonskid)LOT3$ - 0
0003AMRemove existing and install new Nonskid Reconfigurable Space 2 (RECON 2) 3-54-0-Q in accordance with 3.1, 3.6, 3.9 and 3.10. (roll on nonskid)LOT2$ - 0
0003ANRemove existing and install new Nonskid Reconfigurable Space 2 (RECON 2) 3-54-0-Q in accordance with 3.1, 3.7, 3.9 and 3.10. (peel and stick nonskid)LOT3$ - 0
0003APRemove existing and install new Nonskid Mag 1 1-38-0-M in accordance with 3.1, 3.7, 3.9 and 3.10. (peel and stick nonskid)LOT1$ - 0
0003AQRemove existing and install new Nonskid Mag 2 1-38-2-M in accordance with 3.1, 3.7, 3.9 and 3.10. (peel and stick nonskid)LOT1$ - 0
0003ARRemove existing and install new Nonskid port and Starboard Bridge Wings in accordance with 3.1, and 3.8 through 3.10. (peel and stick nonskid)LOT2$ - 0
0003ASRemove existing and install new Nonskid 02 Level Frame 21-26 in accordance with 3.1, and 3.8 through 3.10. (peel and stick nonskid)LOT2$ - 0
0003ATRemove existing and install new Nonskid 02 Level Frame 40-45 in accordance with 3.1, and 3.8 through 3.10. (peel and stick nonskid)LOT2$ - 0
0003AURemove existing and install new Nonskid 02 Level Frame 45-56 in accordance with 3.1, and 3.8 through 3.10. (peel and stick nonskid)LOT2$ - 0
0003AVRemove existing and install new Nonskid 03 Level Frame 23-41 in accordance with 3.1, and 3.8 through 3.10. (peel and stick nonskid)LOT2$ - 0
0003AWRemove existing and install new Nonskid as designated by the SUPERVISOR, 1-50 square feet, in accordance with paragraphs 3.1 through 3.10. (As Per Delivery Order)SF50$ - 0
0003AXRemove existing and install new Nonskid as designated by the SUPERVISOR, 51-250 square feet, in accordance with paragraphs 3.1 through 3.10. (As Per Delivery Order)SF500$ - 0
0003AYRemove existing and install new Nonskid as designated by the SUPERVISOR, 251-500 square feet, in accordance with paragraphs 3.1 through 3.10. (As Per Delivery Order)SF2500$ - 0
0004Remove existing and install new Nonskid in accordance with Work Specification Item 634-11-004 (LHD Class)
0004AARemove existing and install new Nonskid on Flight Deck, in accordance with 3.1, 3.2, 3.7 and 3.8.LOT1$ - 0
0004ABRemove existing and install new Nonskid on Aircraft Hanger, in accordance with 3.1, 3.3, 3.7 and 3.8.LOT1$ - 0
0004ACRemove existing and install new Nonskid on Aircraft Elevator Port Side (Frame 89 to 97) 3,000 square feet, in accordance with 3.1, 3.4, 3.7 and 3.8.LOT1$ - 0
0004ADRemove existing and install new Nonskid on Aircraft Elevator STBD Side (Frame 114 to 121) 3,000 square feet, in accordance with 3.1, 3.4, 3.7 and 3.8.LOT1$ - 0
0004AERemove existing and install new Nonskid on Ramp (03 Level to Hanger Deck), in accordance with 3.1, 3.5, 3.7 and 3.8.LOT1$ - 0
0004AFRemove existing and install new Nonskid on Ramp (Hanger Deck to 3rd Deck), in accordance with 3.1, 3.5, 3.7 and 3.8.LOT1$ - 0
0004AGRemove existing and install new Nonskid on Ramp (3rd Deck to 4th Deck), in accordance with 3.1, 3.5, 3.7 and 3.8.LOT1$ - 0
0004AHRemove existing and install new Nonskid on 3rd Deck Vehicle Stowage, in accordance with 3.1, 3.6, 3.7 and 3.8.LOT1$ - 0
0004AJRemove existing and install new Nonskid on 4th Deck Vehicle Stowage, in accordance with 3.1, 3.6, 3.7 and 3.8.LOT1$ - 0
0004AKRemove existing and install new Nonskid I-10 Passageway, in accordance with paragraph 3.1, and 3.6 through 3.8.LOT1$ - 0
0004ALRemove existing and install new Nonskid as designated by the SUPERVISOR, 1-50 square feet in accordance with paragraph 3.1 through 3.9. (As per Delivery Order)SF50$ - 0
0004AMRemove existing and install new Nonskid as designated by the SUPERVISOR, 51-250 square feet in accordance with paragraph 3.1 through 3.9. (As per Delivery Order).SF100$ - 0
0004ANRemove existing and install new Nonskid as designated by the SUPERVISOR, 251-500 square feet in accordance with paragraph 3.1 through 3.9. (As per Delivery Order).SF500$ - 0
0005Remove existing and install new Nonskid in accordance with Work Specification Item 634-11-005 (All Vessels - Waterjet)
0005AARemove existing nonskid and install new Type V Nonskid as designated by the SUPERVISOR - 1 to 100 square feet per location in accordance with paragraph 3.1, 3.2, 3.6 and 3.7.SF100$ - 0
0005ABRemove existing nonskid and install new Type V Nonskid as designated by the SUPERVISOR - 101 to 500 square feet per location in accordance with paragraph 3.1, 3.2, 3.6 and 3.7.SF500$ - 0
0005ACRemove existing nonskid and install new Type V Nonskid as designated by the SUPERVISOR - 501 to 1000 square feet per location in accordance with paragraph 3.1, 3.2, 3.6 and 3.7.SF1000$ - 0
0005ADRemove existing nonskid and install new Type V Nonskid as designated by the SUPERVISOR - 1 to 100 square feet per location in accordance with paragraph 3.1, 3.3, 3.6 and 3.7.SF50$ - 0
0005AERemove existing nonskid and install new Type V Nonskid as designated by the SUPERVISOR - 101 to 500 square feet per location in accordance with paragraph 3.1, 3.3, 3.6 and 3.7.SF100$ - 0
0005AFRemove existing nonskid and install new Type V Nonskid as designated by the SUPERVISOR - 501 to 1000 square feet per location in accordance with paragraph 3.1, 3.3, 3.6 and 3.7.SF500$ - 0
0005AGRemove existing nonskid and install new Type I Nonskid as designated by the SUPERVISOR - 1 to 100 square feet per location in accordance with paragraph 3.1, 3.4, 3.6 and 3.7.SF50$ - 0
0005AHRemove existing nonskid and install new Type I Nonskid as designated by the SUPERVISOR - 101 to 500 square feet per location in accordance with paragraph 3.1, 3.4, 3.6 and 3.7.SF100$ - 0
0005AJRemove existing nonskid and install new Type I Nonskid as designated by the SUPERVISOR - 501 to 1000 square feet per location in accordance with paragraph 3.1, 3.4, 3.6 and 3.7.SF500$ - 0
0005AKRemove existing nonskid and install new Type IV Nonskid as designated by the SUPERVISOR - 1 to 50 square feet per location in accordance with paragraph 3.1 and 3.5 through 3.7.SF50$ - 0
0005ALRemove existing nonskid and install new Type IV Nonskid as designated by the SUPERVISOR - 51 to 100 square feet per location in accordance with paragraph 3.1 and 3.5 through 3.7.SF100$ - 0
0005AMRemove existing nonskid and install new Type IV Nonskid as designated by the SUPERVISOR - 101 to 500 square feet per location in accordance with paragraph 3.1 and 3.5 through 3.7.SF500$ - 0
0006Remove existing and install new Nonskid In accordance with Work Specification Item 634-11-006 (All Vessels - Abrasive Blast)
0006AARemove existing nonskid and install new Type V Nonskid as designated by the SUPERVISOR - 1 to 100 square feet per location in accordance with paragraph 3.1, 3.2, 3.6 and 3.7.SF100$ - 0
0006ABRemove existing nonskid and install new Type V Nonskid as designated by the SUPERVISOR - 101 to 500 square feet per location in accordance with paragraph 3.1, 3.2, 3.6 and 3.7.SF500$ - 0
0006ACRemove existing nonskid and install new Type V Nonskid as designated by the SUPERVISOR - 501 to 1000 square feet per location in accordance with paragraph 3.1, 3.2, 3.6 and 3.7.SF1000$ - 0
0006ADRemove existing nonskid and install new Type V Nonskid as designated by the SUPERVISOR - 1 to 100 square feet per location in accordance with paragraph 3.1, 3.3, 3.6 and 3.7.SF50$ - 0
0006AERemove existing nonskid and install new Type V Nonskid as designated by the SUPERVISOR - 101 to 500 square feet per location in accordance with paragraph 3.1, 3.3, 3.6 and 3.7.SF100$ - 0
0006AFRemove existing nonskid and install new Type V Nonskid as designated by the SUPERVISOR - 501 to 1000 square feet per location in accordance with paragraph 3.1, 3.3, 3.6 and 3.7.SF500$ - 0
0006AGRemove existing nonskid and install new Type I Nonskid as designated by the SUPERVISOR - 1 to 100 square feet per location in accordance with paragraph 3.1, 3.4, 3.6 and 3.7.SF50$ - 0
0006AHRemove existing nonskid and install new Type I Nonskid as designated by the SUPERVISOR - 101 to 500 square feet per location in accordance with paragraph 3.1, 3.4, 3.6 and 3.7.SF100$ - 0
0006AJRemove existing nonskid and install new Type I Nonskid as designated by the SUPERVISOR - 501 to 1000 square feet per location in accordance with paragraph 3.1, 3.4, 3.6 and 3.7.SF500$ - 0
0006AKRemove existing nonskid and install new Type IV Nonskid as designated by the SUPERVISOR - 1 to 50 square feet per location in accordance with paragraph 3.1 and 3.5 through 3.7.SF50$ - 0
0006ALRemove existing nonskid and install new Type IV Nonskid as designated by the SUPERVISOR - 51 to 100 square feet per location in accordance with paragraph 3.1 and 3.5 through 3.7.SF100$ - 0
0006AMRemove existing nonskid and install new Type IV Nonskid as designated by the SUPERVISOR - 101 to 500 square feet per location in accordance with paragraph 3.1 and 3.5 through 3.7.SF500$ - 0
0007Remove existing and install new Nonskid in accordance with Work Specification Item 634-01-007 (All Vessels)
0007AARemove existing and install new Nonskid ablative deck covering FLEXFRAM 605 and ablative Nonskid FLEXFRAM 605 NS, in accordance with paragraphs 3.1, 3.2 or 3.3, 3.7 and 3.8 - 1 to 50 square feet per location.SF50$ - 0
0007ABRemove existing and install new Nonskid ablative deck covering FLEXFRAM 605 and ablative Nonskid FLEXFRAM 605 NS, in accordance with paragraphs 3.1, 3.2 or 3.3, 3.7 and 3.8 - 51 to 100 square feet per location.SF100$ - 0
0007ACRemove existing and install new Nonskid ablative deck covering FLEXFRAM 605 and ablative Nonskid FLEXFRAM 605 NS, in accordance with paragraphs 3.1, 3.2 or 3.3, 3.7 and 3.8 - 101 to 500 square feet per location.SF500$ - 0
0007ADRemove existing and install new ablative Nonskid FLEXFRAM 605 NS, in accordance with paragraphs 3.1, 3.4 or 3.5, 3.7, and 3.8 - 1 to 50 square feet per location.SF50$ - 0
0007AERemove existing and install new ablative Nonskid FLEXFRAM 605 NS, in accordance with paragraphs 3.1, 3.4 or 3.5, 3.7, and 3.8 - 51 to 100 square feet per location.SF100$ - 0
0007AFRemove existing and install new ablative Nonskid FLEXFRAM 605 NS, in accordance with paragraphs 3.1, 3.4 or 3.5, 3.7, and 3.8 - 101 to 500 square feet per location.SF500$ - 0
0007AGInstall MIL-PRF-24667 Type III Membrane to smooth the deck in accordance with 3.1, 3.6, 3.8, and 3.9. 1-50 square feet per locationSF50$ - 0
0007AHInstall MIL-PRF-24667 Type III Membrane to smooth the deck in accordance with 3.1, 3.6, 3.8, and 3.9. 51-100 square feet per locationSF100$ - 0
0007AJInstall MIL-PRF-24667 Type III Membrane to smooth the deck in accordance with 3.1, 3.6, 3.8, and 3.9. 101-500 square feet per locationSF500$ - 0
0007AKInstall MIL-3135 Underlayment to fill low spots or slope deck to each deck drain in accordance with paragraph 3.1 and 3.7 through 3.9. 1-50 square feet per locationSF50$ - 0
0007ALInstall MIL-3135 Underlayment to fill low spots or slope deck to each deck drain in accordance with paragraph 3.1 and 3.7 through 3.9. 51-100 square feet per locationSF100$ - 0
0007AMInstall MIL-3135 Underlayment to fill low spots or slope deck to each deck drain in accordance with paragraph 3.1 and 3.7 through 3.9. 101-500 square feet per locationSF500$ - 0
0008Remove existing Nonskid and install new Nonskid Peel and Stick Sections in accordance with Work item 634-11-008 (All Vessels)
0008AARemove existing and install new MIL-PRF 24667, Type XI (P & S) Nonskid in accordance with paragraphs 3.1 through 3.4, as designated by the SUPERVISOR - 1 to 50 square feet per location.SF50$ - 0
0008ABRemove existing and install new MIL-PRF 24667, Type XI (P & S) Nonskid in accordance with paragraphs 3.1 through 3.4, as designated by the SUPERVISOR - 51 to 100 square feet per location.SF100$ - 0
0008ACRemove existing and install new MIL-PRF 24667, Type XI (P & S) Nonskid in accordance with paragraphs 3.1 through 3.4, as designated by the SUPERVISOR - 101 to 200 square feet per location.SF200$ - 0
0008ADRemove existing and install new MIL-PRF 24667, Type XI (P & S) Nonskid in accordance with paragraphs 3.1 through 3.4, as designated by the SUPERVISOR - 201 to 500 square feet per location.SF500$ - 0
0008AERemove existing and install new MIL-PRF 24667, Type XI (P & S) Nonskid in accordance with paragraphs 3.1 through 3.4, as designated by the SUPERVISOR - 501 to 1000 square feet per location.SF1000$ - 0
0008AFRemove existing MIL-PRF 24667, Type XI (P & S) Nonskid to bare metal and install MIL-PRF 24667, Type I Nonskid in accordance with paragraphs 3.1 through 3.4, as designated by the SUPERVISOR - 1 to 50 square feet per locationSF50$ - 0
0008AGRemove existing MIL-PRF 24667, Type XI (P & S) Nonskid to bare metal and install MIL-PRF 24667, Type I Nonskid in accordance with paragraphs 3.1 through 3.4, as designated by the SUPERVISOR - 51 to 100 square feet per locationSF100$ - 0
0008AHRemove existing MIL-PRF 24667, Type XI (P & S) Nonskid to bare metal and install MIL-PRF 24667, Type I Nonskid in accordance with paragraphs 3.1 through 3.4, as designated by the SUPERVISOR - 101 to 200 square feet per locationSF200$ - 0
0008AJRemove existing MIL-PRF 24667, Type XI (P & S) Nonskid to bare metal and install MIL-PRF 24667, Type I Nonskid in accordance with paragraphs 3.1 through 3.4, as designated by the SUPERVISOR - 201 to 500 square feet per locationSF500$ - 0
0008AKRemove existing MIL-PRF 24667, Type XI (P & S) Nonskid to bare metal and install MIL-PRF 24667, Type I Nonskid in accordance with paragraphs 3.1 through 3.4, as designated by the SUPERVISOR - 501 to 1,000 square feet per locationSF1000$ - 0
0008ALRemove existing MIL-PRF 24667, Type I, IV, or V Nonskid to bare metal and install MIL-PRF 24667, Type XI (P & S) Nonskid in accordance with paragraphs 3.1 through 3.4, as designated by the SUPERVISOR - 1 to 50 square feet per locationSF50$ - 0
0008AMRemove existing MIL-PRF 24667, Type I, IV, or V Nonskid to bare metal and install MIL-PRF 24667, Type XI (P & S) Nonskid in accordance with paragraphs 3.1 through 3.4, as designated by the SUPERVISOR - 51 to 100 square feet per locationSF100$ - 0
0008ANRemove existing MIL-PRF 24667, Type I, IV, or V Nonskid to bare metal and install MIL-PRF 24667, Type XI (P & S) Nonskid in accordance with paragraphs 3.1 through 3.4, as designated by the SUPERVISOR - 101 to 200 square feet per locationSF200$ - 0
0008APRemove existing MIL-PRF 24667, Type I, IV, or V Nonskid to bare metal and install MIL-PRF 24667, Type XI (P & S) Nonskid in accordance with paragraphs 3.1 through 3.4, as designated by the SUPERVISOR - 201 to 500 square feet per locationSF500$ - 0
0008AQRemove existing MIL-PRF 24667, Type I, IV, or V Nonskid to bare metal and install MIL-PRF 24667, Type XI (P & S) Nonskid in accordance with paragraphs 3.1 through 3.4, as designated by the SUPERVISOR - 501 to 1,000 square feet per locationSF1000$ - 0
0009Additional Work not covered by an ELIN listed above
0009AAAdditional Work - Labor (Enter fully burdened labor rate)HR1000$ - 0
0009ABAdditional Work - Materials (Proposed unit price will be $1.00)LOT$ 1.0010000$ 10,000.00
0009ACApply 2nd coat of primer 1-10 square feetSF10$ - 0
0009ADApply 2nd coat of primer 11-100 square feetSF100$ - 0
0009AEApply 2nd coat of primer 101-1,000 square feetSF1000$ - 0
0009AFPrep, prime, and paint waterway barLF1000$ - 0
0010Use MIL-PRF-24667 Type III in place of Type I
0010AAPer square foot difference in priceSF1$ - 0
0011Use MIL-PRF-24667 Type VI in place of Type I
0011AAPer square foot difference in priceSF1$ - 0
0012Use MIL-PRF-24667 Type VIII in place of Type I
0012AAPer square foot difference in priceSF1$ - 0
0013Labor and Material for Containment Enclosures: Setup, removal, climate control, and lighting system.
0013AAContainment Enclosure - up to 900 square feetDay1$ - 0
0013ABContainment Enclosure - 901 to 1,600 square feetDay1$ - 0
0013ACContainment Enclosure - 1,601 to 4,000 square feetDay1$ - 0
0014Control hazardous waste produced on Naval Vessels in accordance with Work Specification 998-41-001.
0014AAContractor Cleaning Solvents, per gallonGAL1$ - 0
0014ABContractor Spent Abrasives, per tonEA1$ - 0
0014ACPaints (Enamel, Latex, Epoxy, Thinners, Oil Based, Rubber Paint, Lacquer, Removed, Varnishes), per gallonGAL1$ - 0
0014ADPaints (may include Cadmium or Chrome), per poundLB1$ - 0
0014AESludge (Contaminated with a known Hazardous Waste), per gallonGAL1$ - 0

TOTAL ORDERING PERIOD ONE $ 10,000.00

Ordering Period 2

SECTION B CLIN 0002 - ORDERING PERIOD TWO The Government is not obligated, nor is the Government limited, to the quantities listed below. The quantities listed are for estimating purposes only.
ELINDescriptionUnit of IssueUnit PriceEstimated QtyExtended Amount
1001Remove existing and install new Nonskid in accordance with Work Specification Item 634-11-001 (DDG Class)
1001AARemove existing and install new Nonskid Forecastle Deck, Bow to Frame 126, in accordance with paragraphs 3.1, 3.2, 3.6 and 3.7LOT3$ - 0
1001ABRemove existing and install new Nonskid Flight Deck and RAST Track Plate Tops, Frame 399 to Stern, in accordance with paragraphs 3.1, 3.2, 3.6 and 3.7LOT2$ - 0
1001ACRemove existing and install new Nonskid Flight Deck, Frame 370 to stern, in accordance with paragraphs 3.1, 3.2, 3.6 and 3.7LOT2$ - 0
1001ADRemove existing and install new Nonskid Helicopter Hanger No.1 (1-338-3-Q), including RAST Track Plate Tops, in accordance with paragraphs 3.1, 3.2, 3.6 and 3.7LOT2$ - 0
1001AERemove existing and install new Nonskid Helicopter Hanger No. 2 (1-338-8-Q), including RAST Track Plate Tops, in accordance with paragraphs 3.1, 3.2, 3.6 and 3.7LOT2$ - 0
1001AFRemove existing and install new Nonskid 01 Level, Frame 118 to 207, Port Side Castleway/Passageway (01-118-4-L), in accordance with paragraphs 3.1, 3.3, 3.6 and 3.7LOT3$ - 0
1001AGRemove existing and install new Nonskid 01 Level, Frame 118 to 207, STBD Side Castleway/Passageway (01-118-1-L), in accordance with paragraphs 3.1, 3.3, 3.6 and 3.7LOT3$ - 0
1001AHRemove existing and install new Nonskid 01 Level, Frame 204 to 328, Port and STBD Weatherdeck, in accordance with paragraphs 3.1, 3.3, 3.6 and 3.7LOT3$ - 0
1001AJRemove existing and install new Nonskid 01 Level, Frame 204 to 370, Port and STBD Weatherdeck, in accordance with paragraphs 3.1, 3.3, 3.6 and 3.7LOT2$ - 0
1001AKRemove existing and install new Nonskid 02 Level, Frame 110 to 138, Port and STBD Weatherdeck and RAS Station No. 3 and No. 4, Including Intermediate Platforms, in accordance with paragraphs 3.1, 3.3, 3.6 and 3.7LOT3$ - 0
1001ALRemove existing and install new Nonskid Forward CIWS Magazine (02-112-2-M), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
1001AMRemove existing and install new Nonskid 02 Level, Frame 193 to 228, Port and STBD Weatherdeck, in accordance with paragraphs 3.1, 3.5, 3.6 and 3.7LOT2$ - 0
1001ANRemove existing and install new Nonskid 02 Level, Frame 228 to 237, NUKLA Platform, in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT3$ - 0
1001APRemove existing and install new Nonskid 02 Level, Frame 242 to 312, Port and STBD Weatherdeck, in accordance with paragraphs 3.1, 3.5, 3.6 and 3.7LOT3$ - 0
1001AQRemove existing and install new Nonskid 02 Level, Frame 312 to 396, Port and STBD Weatherdeck, in accordance with paragraphs 3.1, 3.3, 3.6 and 3.7LOT2$ - 0
1001ARRemove existing and install new Nonskid 03 Level, Frame 145 to 193, Port and STBD Weatherdeck, in accordance with paragraphs 3.1, 3.5, 3.6 and 3.7LOT3$ - 0
1001ASRemove existing and install new Nonskid 04 Level, Frame 140 to 176, Port and STBD Weatherdeck, including Bridge Wings and Signal Bridge, in accordance with paragraphs 3.1, 3.5, 3.6 and 3.7LOT3$ - 0
1001ATRemove existing and install new Nonskid 05 Level, Frame 130 to 170, Port and STBD Weatherdeck, in accordance with paragraphs 3.1, 3.5, 3.6 and 3.7LOT3$ - 0
1001AURemove existing and install new Nonskid 06 Level, Frame 137 to 165, Port and STBD Weatherdeck, in accordance with paragraphs 3.1, 3.5, 3.6 and 3.7LOT3$ - 0
1001AVRemove existing and install new Nonskid Weapons & Aviation Ordnance Equipment Workshop (01-300-0-Q), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT3$ - 0
1001AWRemove existing and install new Nonskid Weapons Magazine (01-300-1-M), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
1001AXRemove existing and install new Nonskid AFT CIWS Magazine No.2 (01-300-2-M), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
1001AYRemove existing and install new Nonskid passageway (1-42-01-L), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
1001AZRemove existing and install new Nonskid Torpedo Missile and Rocket Magazine (1-304-2-M), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
1001BARemove existing and install new Nonskid Fixed Gun Ammunition Rocket Magazine (1-318-2-M), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
1001BBRemove existing and install new Nonskid Aviation Repair Shop (1-381-0-Q), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
1001BCRemove existing and install new Nonskid General Workshop (2-200-2-Q), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
1001BDRemove existing and install new Nonskid passageway (2-370-2-L), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
1001BERemove existing and install new Nonskid passageway (2-370-3-L), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
1001BFRemove existing and install new Nonskid passageway (2-370-4-L), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
1001BGRemove existing and install new Nonskid passageway (2-374-2-L), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
1001BHRemove existing and install new Nonskid passageway (2-374-4-L), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
1001BJRemove existing and install new Nonskid passageway (2-410-0-L), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
1001BKRemove existing and install new Nonskid RAST Machinery Room (2-442-0-E), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT2$ - 0
1001BLRemove existing and install new Nonskid 5/54 Projectile Magazine (3-42-0-M) in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT1$ - 0
1001BMRemove existing and install new Nonskid 5/54 Powder Magazine No. 1 (3-62-1-M) in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT1$ - 0
1001BNRemove existing and install new Nonskid Powder Magazine No.1 (3-68-1-M), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT1$ - 0
1001BPRemove existing and install new Nonskid, Powder Magazine No. 2 (3-68-2-M), in accordance with paragraphs 3.1, 3.4, 3.6 and 3.7LOT1$ - 0
1001BQRemove existing and install new Nonskid as designated by the SUPERVISOR, 1-50 square feet, in accordance with paragraphs 3.1 through 3.7. (As Per Delivery Order)SF50$ - 0
1001BRRemove existing and install new Nonskid as designated by the SUPERVISOR, 51-250 square feet, in accordance with paragraphs 3.1 through 3.7. (As Per Delivery Order)SF500$ - 0
1001BSRemove existing and install new Nonskid as designated by the SUPERVISOR, 251-500 square feet, in accordance with paragraphs 3.1 through 3.7. (As Per Delivery Order)SF2500$ - 0
1002Remove existing and install new Nonskid in accordance with Work Specification Item 634-11-002 (CG Class)
1002AARemove existing and install new Nonskid Forecastle Deck, Bow to Frame 138, in accordance with paragraphs 3.1, 3.2, and 3.7.LOT1$ - 0
1002ABRemove existing and install new Nonskid Main Deck, Frame 454 to Stern, in accordance with paragraphs 3.1, 3.2, and 3.7.LOT1$ - 0
1002ACRemove existing and install new Nonskid Helicopter Hanger 02-292-2-Q, including RAST Track Plate Tops, in accordance with paragraphs 3.1, 3.3, and 3.7.LOT1$ - 0
1002ADRemove existing and install new Nonskid Flight Deck, 02 Level, Frame 346 to 418, including RAST Track Plate Tops, in accordance with paragraphs 3.1, 3.3, and 3.7.LOT1$ - 0
1002AERemove existing and install new Nonskid Port Boat Deck, Frame 270 to 304, in accordance with paragraphs 3.1, 3.5,and 3.7.LOT1$ - 0
1002AFRemove existing and install new Nonskid STBD Boat Deck, Frame 270 to 294, in accordance with paragraphs 3.1, 3.5, and 3.7.LOT1$ - 0
1002AGRemove existing and install new Nonskid Passageway (01-138-2-L), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002AHRemove existing and install new Nonskid Passageway (01-138-3-L), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002AJRemove existing and install new Nonskid 01 Level, Frame 174 to 409, Port Side, in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002AKRemove existing and install new Nonskid 01 Level, Frame 174 to 409, STBD Side, in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002ALRemove existing and install new Nonskid 01 Level, Frame 409 to 472, in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002AMRemove existing and install new Nonskid 04 Level, Frame 174 to 248, in accordance with paragraphs 3.1, 3.5, and 3.7.LOT1$ - 0
1002ANRemove existing and install new Nonskid 04 Level, Frame 289 to 346, in accordance with paragraphs 3.1, 3.5, and 3.7.LOT1$ - 0
1002APRemove existing and install new Nonskid 03 Level, Frame 180 to 289, in accordance with paragraphs 3.1, 3.5, and 3.7.LOT1$ - 0
1002AQRemove existing and install new Nonskid Helicopter Repair Shop (02-276-01-Q), in accordance with paragraphs 3.1, 3.5, and 3.7.LOT1$ - 0
1002ARRemove existing and install new Nonskid RAST Machinery Room (01-382-0-Q), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002ASRemove existing and install new Nonskid Sonobuoy Storeroom (01-398-1-A), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002ATRemove existing and install new Nonskid Windlass Room (1-0-0-E), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002AURemove existing and install new Nonskid 5/54 Loader Drum Room No. 1 (1-58-0-M), in accordance with paragraphs 3.1, 3.4, and 3.7 .LOT1$ - 0
1002AVRemove existing and install new Nonskid Torpedo Room No. 1 (1-390-1-M), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002AWRemove existing and install new Nonskid Torpedo Room No. 2 (1-390-4-M), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002AXRemove existing and install new Nonskid 5/54 Ammo Pallet Staging Room No.1 (2-58-0-Q), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002AYRemove existing and install new Nonskid Reefer Machinery Room (2-220-4-Q), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002AZRemove existing and install new Nonskid Filter Cleaning Shop (2-382-4-Q), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002BARemove existing and install new Nonskid General Workshop (2-387-0-Q), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002BBRemove existing and install new Nonskid Stores Handling Room (2-464-0-A), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002BCRemove existing and install new Nonskid 5/54 Loader Drum Room No. 2 (2-482-0-M), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002BDRemove existing and install new Nonskid 5/54 Projectile Magazine No. 1 (3-62-0-M), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002BERemove existing and install new Nonskid Mk 26 Magazine No. 1 (3-97-01-M), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002BFRemove existing and install new Nonskid Pump Room No. 2 & AC Machinery Room (3-398-0-E), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002BGRemove existing and install new Nonskid Mk 26 Magazine No. 2 (3-435-01-M), in accordance with paragraphs 3.1, 3.4,and 3.7.LOT1$ - 0
1002BHRemove existing and install new Nonskid 5/54 Ammo Pallet Staging Room No. 2 (3-464-0-Q), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002BJRemove existing and install new Nonskid 5/54 Projectile Magazine No. 2 (3-482-0-M), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002BKRemove existing and install new Nonskid 5/54 Powder Magazine No. 3 (3-494-0-M), in accordance with paragraphs 3.1, 3.4, and 3.7.LOT1$ - 0
1002BLRemove existing and install new Nonskid as designated by the SUPERVISOR, 1-50 square feet, in accordance with paragraphs 3.1 through 3.7. (As Per Delivery Order)SF50$ - 0
1002BMRemove existing and install new Nonskid as designated by the SUPERVISOR, 51-250 square feet, in accordance with paragraphs 3.1 through 3.7. (As Per Delivery Order)SF500$ - 0
1002BNRemove existing and install new Nonskid as designated by the SUPERVISOR, 251-500 square feet, in accordance with paragraphs 3.1 through 3.7. (As Per Delivery Order)SF2500$ - 0
1003Remove existing and install new Nonskid in accordance with Work Specification Item 634-11-003 (LCS Freedom Class)
1003AARemove existing and install new Nonskid Flight Deck in accordance with paragraphs 3.1, 3.2, 3.9 and 3.10.LOT3$ - 0
1003ABRemove existing and install new Nonskid Airborne Mission Zone (AMZ) in accordance with 3.1, 3.2, 3.9 and 3.10. (roll on nonskid)LOT2$ - 0
1003ACRemove existing and install new Nonskid Airborne Mission Zone (AMZ) in accordance with 3.1, 3.3, 3.9 and 3.10. (spray on nonskid)LOT2$ - 0
1003ADRemove existing and install new Nonskid Forecastle in accordance with 3.1, 3.4, 3.9 and 3.10. (spray on nonskid)LOT2$ - 0
1003AERemove existing and install new Nonskid Forecastle in accordance with 3.1, 3.5, 3.9 and 3.10. roll on nonskid.)LOT2$ - 0
1003AFRemove existing and install new Nonskid Boat Deck and Pway 1-31-4-Q in accordance with 3.1, 3.4, 3.9 and 3.10. spray on nonskid)LOT2$ - 0
1003AGRemove existing and install new Nonskid Boat Deck and Pway 1-31-4-Q in accordance with 3.1, 3.5, 3.3.9 and 3.10. roll on nonskid)LOT2$ - 0
1003AHRemove existing and install new Nonskid Water Borne Mission Zone (WMZ) 3-65-0-Q in accordance with 3.1, 3.4, 3.9 and 3.10. (spray on nonskid)LOT2$ - 0
1003AJRemove existing and install new Nonskid Water Borne Mission Zone (WMZ) 3-65-0-Q in accordance with 3.1 3.5, 3.9 and 3.10. roll on nonskid)LOT3$ - 0
1003AKRemove existing and install new Nonskid Reconfigurable Space 1 (RECON 1) 3-45-0-Q in accordance with 3.1, 3.6, 3.9 and 3.10. (roll on nonskid)LOT2$ - 0
1003ALRemove existing and install new Nonskid Reconfigurable Space 1 (RECON 1) 3-45-0-Q in accordance with 3.1, and 3.7 through 3.9. (peel and stick nonskid)LOT3$ - 0
1003AMRemove existing and install new Nonskid Reconfigurable Space 2 (RECON 2) 3-54-0-Q in accordance with 3.1, 3.6, 3.9 and 3.10. (roll on nonskid)LOT2$ - 0
1003ANRemove existing and install new Nonskid Reconfigurable Space 2 (RECON 2) 3-54-0-Q in accordance with 3.1, 3.7, 3.9 and 3.10. (peel and stick nonskid)LOT3$ - 0
1003APRemove existing and install new Nonskid Mag 1 1-38-0-M in accordance with 3.1, 3.7, 3.9 and 3.10. (peel and stick nonskid)LOT1$ - 0
1003AQRemove existing and install new Nonskid Mag 2 1-38-2-M in accordance with 3.1, 3.7, 3.9 and 3.10. (peel and stick nonskid)LOT1$ - 0
1003ARRemove existing and install new Nonskid port and Starboard Bridge Wings in accordance with 3.1, and 3.8 through 3.10. (peel and stick nonskid)LOT2$ - 0
1003ASRemove existing and install new Nonskid 02 Level Frame 21-26 in accordance with 3.1, and 3.8 through 3.10. (peel and stick nonskid)LOT2$ - 0
1003ATRemove existing and install new Nonskid 02 Level Frame 40-45 in accordance with 3.1, and 3.8 through 3.10. (peel and stick nonskid)LOT2$ - 0
1003AURemove existing and install new Nonskid 02 Level Frame 45-56 in accordance with 3.1, and 3.8 through 3.10. (peel and stick nonskid)LOT2$ - 0
1003AVRemove existing and install new Nonskid 03 Level Frame 23-41 in accordance with 3.1, and 3.8 through 3.10. (peel and stick nonskid)LOT2$ - 0
1003AWRemove existing and install new Nonskid as designated by the SUPERVISOR, 1-50 square feet, in accordance with paragraphs 3.1 through 3.10. (As Per Delivery Order)SF50$ - 0
1003AXRemove existing and install new Nonskid as designated by the SUPERVISOR, 51-250 square feet, in accordance with paragraphs 3.1 through 3.10. (As Per Delivery Order)SF500$ - 0
1003AYRemove existing and install new Nonskid as designated by the SUPERVISOR, 251-500 square feet, in accordance with paragraphs 3.1 through 3.10. (As Per Delivery Order)SF2500$ - 0
1004Remove existing and install new Nonskid in accordance with Work Specification Item 634-11-004 (LHD Class)
1004AARemove existing and install new Nonskid on Flight Deck, in accordance with 3.1, 3.2, 3.7 and 3.8.LOT1$ - 0
1004ABRemove existing and install new Nonskid on Aircraft Hanger, in accordance with 3.1, 3.3, 3.7 and 3.8.LOT1$ - 0
1004ACRemove existing and install new Nonskid on Aircraft Elevator Port Side (Frame 89 to 97) 3,000 square feet, in accordance with 3.1, 3.4, 3.7 and 3.8.LOT1$ - 0
1004ADRemove existing and install new Nonskid on Aircraft Elevator STBD Side (Frame 114 to 121) 3,000 square feet, in accordance with 3.1, 3.4, 3.7 and 3.8.LOT1$ - 0
1004AERemove existing and install new Nonskid on Ramp (03 Level to Hanger Deck), in accordance with 3.1, 3.5, 3.7 and 3.8.LOT1$ - 0
1004AFRemove existing and install new Nonskid on Ramp (Hanger Deck to 3rd Deck), in accordance with 3.1, 3.5, 3.7 and 3.8.LOT1$ - 0
1004AGRemove existing and install new Nonskid on Ramp (3rd Deck to 4th Deck), in accordance with 3.1, 3.5, 3.7 and 3.8.LOT1$ - 0
1004AHRemove existing and install new Nonskid on 3rd Deck Vehicle Stowage, in accordance with 3.1, 3.6, 3.7 and 3.8.LOT1$ - 0
1004AJRemove existing and install new Nonskid on 4th Deck Vehicle Stowage, in accordance with 3.1, 3.6, 3.7 and 3.8.LOT1$ - 0
1004AKRemove existing and install new Nonskid I-10 Passageway, in accordance with paragraph 3.1, and 3.6 through 3.8.LOT1$ - 0
1004ALRemove existing and install new Nonskid as designated by the SUPERVISOR, 1-50 square feet in accordance with paragraph 3.1 through 3.9. (As per Delivery Order)SF50$ - 0
1004AMRemove existing and install new Nonskid as designated by the SUPERVISOR, 51-250 square feet in accordance with paragraph 3.1 through 3.9. (As per Delivery Order).SF100$ - 0
1004ANRemove existing and install new Nonskid as designated by the SUPERVISOR, 251-500 square feet in accordance with paragraph 3.1 through 3.9. (As per Delivery Order).SF500$ - 0
1005Remove existing and install new Nonskid in accordance with Work Specification Item 634-11-005 (All Vessels - Waterjet)
1005AARemove existing nonskid and install new Type V Nonskid as designated by the SUPERVISOR - 1 to 100 square feet per location in accordance with paragraph 3.1, 3.2, 3.6 and 3.7.SF100$ - 0
1005ABRemove existing nonskid and install new Type V Nonskid as designated by the SUPERVISOR - 101 to 500 square feet per location in accordance with paragraph 3.1, 3.2, 3.6 and 3.7.SF500$ - 0
1005ACRemove existing nonskid and install new Type V Nonskid as designated by the SUPERVISOR - 501 to 1000 square feet per location in accordance with paragraph 3.1, 3.2, 3.6 and 3.7.SF1000$ - 0

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .