BESS-Additional-SiteData-N3943020T2238 Amd 1.pdf

PDF 8 MB Posted

Attached to
Design and Procure a Battery Energy Storage System (BESS)
Solicitation number
N3943020T2238
Issued by

View the file

Other files

File Type Posted
N3943020T2238 BESS RFQ Amd 0003.pdf PDF
Generator Specs-Attachment-2.xlsx XLSX spreadsheet
MDP Photos-Attachment-1.pdf PDF
J-2_Financial_Inst_Bank_Information-Revised.docx DOCX document
N3943020T2238 BESS RFQ Amd 0002.pdf PDF
N3943020T2238 BESS RFQ Amendment 0001.pdf PDF
IMG_1804.pdf PDF
N3943020T2236 BESS RFQ.pdf PDF
IMG_1811.pdf PDF
PH-372 BCO Ventura ESS Node Site.pdf PDF
IMG_1812.pdf PDF
372B7Oct19MeterData.xlsx XLSX spreadsheet
J-2_Financial_Inst_Bank_Information.docx DOCX document
B372-Map.pdf PDF
J-3_Pricing Sheet.xlsx XLSX spreadsheet
J-1_Non-Disclosure.docx DOCX document
Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BESS Project

• Incoming power supply

Primary transformer

Main service disconnect to Bldg. and Meter

Step down transformer to Bldg. (75KVA 208-480Y/277

"Approved for public release: distribution unlimited."

Transformer Data Plate that Feeds PH 372

Main service disconnect and Meter

Close up of Meter voltage supplying power to MDP Panel (Note: ATS and emergency generator is not connected to this panel)

Generator and ATS

"Approved for public release: distribution unlimited."

Generator Data Plate

125 Amp ATS

• This panel is connected to the

ATS

• There is no disconnect or main breaker (Main breaker is located upstream, 200 Amp service disconnect)

• Panel supplies power to two sub panels-NMCI panel that has two 20 amp Single pole breakers and a DC panel that has a 100 amp main breaker

• Service connections are supplied on power bus bar and connected to both sub panels

• Pictures attached for reference

• Grid power is supplied to ATS and is connected to panel. Panel supplies power to sub panels from main lugs

• Two Air Conditioning systems are powered from this panel Circuit breaker 1,3,5- 3 pole 30amp Circuit breaker 7,9,11- 3 pole 40 amp

• MDP panel has a 200 Amp service breaker that supplies power to this panel (200 amp panel is upstream)

Incoming power (Grid) supplied from ATS and connected to two sub panels

• Direct Current 100Amp panel, (services UPS system)

DC Service panel

100Amp DC Panel

Sub Panel Qty 2-2 pole 20 amp sub panel (supplies power to computer systems)

Direct Current UPS System

UPS Battery’s

• Older wall mounted AC unit 3 pole 40 amp breaker.

Data Plate for Pad mounted Air Conditioning -208v 3 pole 30 amp breaker

"Approved for public release:

distribution unlimited."

NMCI 2

pole 20 A

Communication panel backed up from Generator

DC panel to UPS system125A ATSG

Main Dist. MDP 200Amp

208/120v 3PH 4W

XFMR to

BLDG

208/120v

3PH 4W

Meters

POLE

Connection Diagram

Disclaimer: Accuracy of Information is not guaranteed. Contractors shall verify the accuracy.

BESS Project
Slide Number 2
Slide Number 3
Slide Number 4
Slide Number 5
Generator Data Plate
125 Amp ATS
Slide Number 8
Slide Number 9
Slide Number 10
Slide Number 11
Slide Number 12
Direct Current UPS System
UPS Battery’s
Slide Number 15
Slide Number 16
Slide Number 17