This document contains answers to questions from potential offerors regarding Solicitation Number N3220521R4011 for the regular overhaul and dry docking of USNS CITY OF BISMARCK (T-EPF 9). The Military Sealift Command seeks products and services including dry docking and undocking, approach berth and mooring requirements, hull modification and repair, potable water systems, canvas covers, unrep and vertrep equipment testing, underwater hull cleaning and painting, inspection of bilge pumps and other mechanical systems, maintenance of stern ramps, inspection of self-contained breathing apparatus and related equipment, inspection and testing of fixed gas and cargo hold sprinkler firefighting systems, inspection of fire doors and shutters, certification of the helideck engine fuel system, and relocation of morin valves and modification of fire damper fuse links. References required to formulate offers are provided to offerors through the Department of Defense Safe system upon request.
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MILITARY SEALIFT COMMAND
N3220521R4011
QUESTIONS AND ANSWERS #3
The following are answers to questions received from potential offerors. The answers provide clarification only and DO NOT constitute an amendment to the solicitation.
QUESTION #23:
SPECIFICATION ITEM NO.: 0901
PARAGRAPH / SECTION NO: Section M, Subfactor 2.3 Facilities
TITLE: TEPF CSI DRYDOCKING AND UNDOCKING
Can the Customer provide the three ship (T-EPF 9) reports required to complete the drydock structural details required to complete the Docking Plan?
ANSWER:
See General Note 1 on Reference 8388185 – Docking Plan and Paragraph 3.2 of WI 0901
QUESTION #24:
SPECIFICATION ITEM NO.: 0003
PARAGRAPH / SECTION NO: Section M, Subfactor 2.3 Facilities
TITLE: APPROACH BERTH AND MOORING REQUIREMENTS
| 1) | Can the Customer provide the Number of Ship’s (T-EPF 9) Mooring lines and there size? |
| 2) | Will the Customer or Offeror provide these mooring lines? |
Per WI 0003 Paragraph 7.4.3.6. - The arrangement of all mooring lines between the ship and mooring securements. All mooring lines shall be provided by the contractor. Mooring lines shall be identified by manufacturer, model/brand, size and breaking strength. Use of mixed lines is not permitted.
QUESTION #25:
SPECIFICATION ITEM NO.: 00120 B
PARAGRAPH / SECTION NO: 2.1.2 & 2.1.3
TITLE: HULL MODIFICATION/REPAIR
Can the Customer provide missing references 2.1.2 and 2.1.3 to all bidders?
Reference 2.1.2 has been updated to drawing number 8445660 and reference 8442868 will be provided via DoD Safe.
QUESTION #26:
SPECIFICATION ITEM NO.: Attachment J-2 Category A Items
PARAGRAPH / SECTION NO: Item 0503
TITLE: Attachment J-2 Category A Items
Contractor notes that Category “B” Item 503, POTABLE WATER SYSTEM is listed in the Attachment J-2 Category A Items document.
Will the Customer provide a revised Attachment J-2 Category A Items document to all bidders?
Please see revised J-2 posted to SAM.gov.
QUESTION #27:
SPECIFICATION ITEM NO.: 0601
PARAGRAPH / SECTION NO: 7.1
TITLE: TEPF Canvas Covers
7.1 The contractor shall fabricate canvas coverings for all items listed in Paragraph 3.1.
Please provide the dimensions for the following items;
3.1.1 Port and Starboard Bunker Stations
3.1.2 Capstan Controllers
3.1.3 Port and Starboard Bunker and FAS Station TLI Boards
3.1.4 Fast Rescue Boat Helm Cover
ANSWER:
Please see below and also provided via DoD Safe Dimensions are approximate and shall be confirmed by contractor prior to fabricating covers.
FAS TLI Board:
Height 25" Width 23.5" Depth 12" Capstan Control Box:
Height 20" Width 24" (incl. e-stop) Depth 9.5"
Bunker Station TLI Height: 25" Width: 36" Depth: 12"
QUESTION #28:
SPECIFICATION ITEM NO.: 1001
PARAGRAPH / SECTION NO: 2.1.1
TITLE: TEPF_CSI_UNREPVERTREP EQUIPMENT AND SYSTEM TESTING
Please provide missing references listed below for item 1001
2.1 NAVSEA Tech Manual 0978-LP-035-3010, Tech Manual Single Probe Fueling System
Reference provided via DoD Safe.
QUESTION #29:
SPECIFICATION ITEM NO.: 0989
PARAGRAPH / SECTION NO: 2.1
TITLE: TEPF_CSI_UNDERWATER HULL CLEANING AND PAINTING
Please provide missing reference for item 0989
2.1 JHSV-9 Paint Reference File
Reference provided via DoD Safe
QUESTION #30:
SPECIFICATION ITEM NO.: 0532
PARAGRAPH / SECTION NO: 7.5.1
TITLE: TEPF_CSI_INSPECT SUBMERSIBLE BILGE PUMPS (CONFINED SPACES - FOREPEAKS AND VOIDS) (1 YR)
Item 532, Para 7.5.1, please provide cut sheet details for the 34 check valves that are to be CFM.
Para 7.5.2, please provide supplier for the discharge connections (P/N 7244503) that is to be CFM.
Information required to provide firm fixed price for this work item.
Reference 8445685 provided via DoD Safe. For 7.5.2, Discharge connections are manufactured by Flygt. Reference provided via DoD Safe.
QUESTION #31:
SPECIFICATION ITEM NO.: 0509
PARAGRAPH / SECTION NO: 2.1
TITLE: CSI HP AIR COMPRESSOR REPLACEMENT (8K HRS)
Item 509, Ref, 2.1 NAVSEA Tech Manual S6220-Fk-MMC-010, Equipment Tech Manual for Air Compressor Model WP-22L.
Reference required to provide firm fixed price for this item.
Reference provided via DoD Safe
QUESTION #32:
SPECIFICATION ITEM NO.: 0532
PARAGRAPH / SECTION NO: 1.1
TITLE: INSPECT SUBMERSIBLE BILGE PUMPS
Item 532, Ref, 1.1 NAVSEA Drawing No. 8445658, Schematic – Bilge System
Reference required to provide firm fixed price for this work item.
Reference provided via DOD Safe.
QUESTION #33:
SPECIFICATION ITEM NO.: 0536
PARAGRAPH / SECTION NO: 2.1.1, 2.1.2 and 2.1.4
TITLE: CSI STERN RAMP MAINTENANCE SPECIAL SURVEY (5 YR) (SCSI) (2)
Item 536, Ref,
2.1.1 NAVSEA Final Technical Manual S9169-BE-MMC-010, Stern Ramp Model A07364 (T-EPF 630 AF)
| 2.1.2 Drawing No. F165281, Hydraulic Assembly for T-EPF 1 or Drawing No. F165291, Hydraulic Assembly for T-EPF 2 and Follow |
| 2.1.4 NAVSEA Document 633-575-09-601, Stage II System Verification and Validation Ramp Weight Test |
Reference required to provide firm fixed price for this work item.
References provided via DoD Safe. For 2.1.2, see page 1053 of Ref 2.1.1.
QUESTION #34:
SPECIFICATION ITEM NO.: 0562
PARAGRAPH / SECTION NO: 2.1.5
TITLE: CCSI SCBA ANNUAL INSPECTION (2)
Item 562, Ref, 2.1.5 2020 SCBA Service Report
Reference required to provide firm fixed price for this work item.
Reference 2.1.5 should be deleted. All information from last service is in Reference 2.1.7 – SOLAS Tracker previously provided via DoD Safe.
QUESTION #35:
SPECIFICATION ITEM NO.: 0563
PARAGRAPH / SECTION NO: 2.1
TITLE: CCSI SCBA AIR COMPRESSOR AND FILLING STATION INSPECTION AND MAINTENANCE (1 YR)
Item 563, Ref, 2.1 NAVSEA Tech Manual S6220-FL-MMC-010, High Pressure Breathing Air Compressor Unit
Reference required to provide firm fixed price for this work item.
Reference provided via DOD Safe.
QUESTION #36:
SPECIFICATION ITEM NO.: 0565
PARAGRAPH / SECTION NO: 2.1.2 & 2.1.3
TITLE: FIXED GAS FIREFIGHTING SYSTEM INSPECTION AND TEST (1 YR) (SCSI) (2)
Item 565, Ref,
2.1.2 NAVSEA Tech Manual T9555-E6-MMC-010, Equipment Technical Manual for FM200 Fixed Gas Fire Extinguishing System, Model JG-6323
2.1.3 MSC.1/Circ.1432, 31 May 2012, Revised Guidelines for the Maintenance and Inspection of Fire Protection Systems and Appliances
Reference required to provide firm fixed price for this work item.
References provided via DoD Safe.
QUESTION #37:
SPECIFICATION ITEM NO.: 0566
PARAGRAPH / SECTION NO: 2.1.1 & 2.1.2
TITLE: CCSI CARGO HOLD SPRINKLER SYSTEM (ANNUAL)
Item 566, Ref,
2.1.1 555-8443287; Fire Control Plan
2.1.2 8443232; Schematic and Layout- Sprinkler System
Reference required to provide firm fixed price for this work item.
QUESTION #38:
SPECIFICATION ITEM NO.: 0574
PARAGRAPH / SECTION NO: 2.1.1 & 2.1.2
TITLE: CCSI FIRE DOORS AND SHUTTERS (1 YR) (SCSI) (2)
Item 574, Ref,
2.1.3 MSC Drawing No. 602-8497675, Galley Roller Doors Replacement and Installation
2.1.4 MSC Drawing No. 202-8497676, Galley Roller Doors Control and Power Modification
Reference required to provide firm fixed price for this work item.
QUESTION #39:
SPECIFICATION ITEM NO.: 0582
PARAGRAPH / SECTION NO: 2.1 & 2.2
TITLE: CSI HEF SYSTEM CERTIFICATION
Item 582, Ref,
2.1 EPF HEF (and Fire main) Preventative Maintenance Sched.
2.2 EPF Class Post-Delivery Engine Room HEF Test Procedure REV 3
Reference required to provide firm fixed price for this work item.
QUESTION #40:
SPECIFICATION ITEM NO.: 0583
PARAGRAPH / SECTION NO: Ref 2.1.1, 2.1.2, 2.1.3 and 2.1.4
TITLE: MORIN VALVE RELOCATION (TALT 106)
Item 583, Ref,
2.1.1 Austal Drawing No. 630-555-01-606, Rev Y, Selected Record Drawing - Schematic & Arrangement – HEF System.
2.1.2 MSC Drawing No. 803-7080803, Computer Aided Designed (CAD) Drawings
2.1.3 MSC Drawing No. 803-7081122, General technical Requirements (GTRs)
2.1.4 NAVSEA Drawing No. 6965791, Flushing Procedure of New, Repaired or Disturbed Piping Sections for Surface Ships
Reference required to provide firm fixed price for this work item.
QUESTION #41:
SPECIFICATION ITEM NO.: 0584
PARAGRAPH / SECTION NO: 2.1.1 & 2.1.2
TITLE: HEF FIRE DAMPER FUSE LINK REMOVAL
Item 584, Ref,
2.1.1 MSC General Technical Requirements (GTR) Drawing 803-7081122
2.1.2 Fire Damper Workshop Item ITM_002563 WS1301
Reference required to provide firm fixed price for this work item.