Text version
N32205-15-R-1006
USNS LENTHALL (T-AO 189)
REQUEST FOR SPECIFICATION CLARIFICATION
NAME OF CONTRACTOR: ___________________________
SPECIFICATION ITEM NO.: ____Various_________________
PARAGRAPH / SECTION NO:___Various_________________
TITLE: _________________________________________________________________
QUESTION:
| Item 102 | Paragraph 7.2 & 7.4 of this item states (39) tanks listed on enclosure 2.2.1. Enclosure 2.2.1 (pages102-8 & 9 of spec), list a total of (59) tanks. Enclosure 2.2.1 (provided under enclosures-references), list a total of (75) tanks. Please clarify which quantity/enclosure is correct. |
| Item 305 | Para 1.1 and 7.1 instructs us to provide the OEM rep. Para 4.1 has the OEM rep as government furnished, also the same OEM rep is indicated as government furnished in item 306, para 4.3. Please clarify |
Item 908 This item is missing from the J-2 attachment.
ANSWER:
The total number to tanks to be rafted per work item 102 is thirty-nine (39). Please note that work item 021 Clean and Gas Free Tanks, Voids, Cofferdams & Spaces is for all the tanks a total of Seventy-nine (79).
The contractor is to provide the Services of the OEM to support the whole cargo console installation including items 306, 307, 308.
J-2 attachment has been revised
ATTACHMENT J - 8