A0002 N00189-13-R-Z065.doc

DOC document 46 KB Posted

Attached to
Radio Frequency Shielded Enclosures in support of ROTHR
Solicitation number
N00189-13-R-Z065
Issued by

About this file

Amendments

View the file

Other files

File Type Posted
13-R-Z065-0017.doc DOC document
13-R-Z065-0016.doc DOC document
13-R-Z065-0015.doc DOC document
N00189-13-R-Z065_Exhibit_A_SOW_thru_A0014.docx DOCX document
N00189-13-R-Z065-conformed_thru_Amend14.doc DOC document
13-R-Z065-0014.doc DOC document
site_visit_clarification.docx DOCX document
g340557_d_all.pdf PDF
g539689_e_all.pdf PDF
g315826_c_all.pdf PDF
13-R-Z065-0013.doc DOC document
g539688_e_all.pdf PDF
g340174_b_all 1 .pdf PDF
NSA Northwest Directions.docx DOCX document
NSA Northwest Annex Base Visit Request Template.docx DOCX document
New Kent Directions.docx DOCX document
13-R-Z065-0012.doc DOC document
13-R-Z065-0011.doc DOC document
13-R-Z065-0010.doc DOC document
13-R-Z065-0009.doc DOC document
g525357_e_all —
A0001 N00189-13-R-Z065.doc DOC document
g525118_j_all —
A00003 13RZ065.doc DOC document
g525359_w_all.pdf PDF
g525358_e_all —
Techncial Drawing G525356_v_all.pdf PDF
ROTHR_Enclosures_Amend4-8.zip ZIP file
ROTHR_Enclosures_Technical.zip ZIP file
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

Part I

Questions received in response to Solicitation N00189-13-R-Z065:

NOTE: PART I IS PROVIDED FOR INFORMATIONAL PURPOSES ONLY AND DOES NOT BECOME PART OF THE SOLICITATION. THE CONTENT OF PART I DOES NOT AMEND THE CONTENTS OF THE SOLICITATION. SEE PART II FOR REVISIONS TO THE SOLICITATION.

1. I was able to download the drawings and think there is one missing from the site which is G525360. The drawing is needed per the #1 note on G525359 & G525356. Please consider adding to technical supplied information.

Response: The contents of G525360 consist solely of the written technical specifications for the required enclosures with some accompanying figures. The contents of G525360 have been updated and incorporated in their entirety into Solicitation N00189-13-R-Z065 as the Section C Statement of Work (SOW) Technical Specifications, and therefore furnished to offerors.

2. There are a few errors in the Solicitation. The CLIN items listing, the Transmit Sounder Enclosure and Receive Sounder Enclosure as stated as 8'x8'x12', drawings shows 8'x8'x20' (example ITEM 0005AA).

a. Transmit Sounder Enclosure and Receive Sounder Enclosure stated as 8’x8’x12’, drawings show

8’x8’x20’

b. Receive Site Monitor G525359 states (2) 8'x8'x20' and (1) 8'x8'x12', drawings look like (4) 8'x7'x20' shelters (need the G525360 drawing to validate)

c. Transmit Site Monitor G525356 states (2) 8'x8'x20' and (1) 8'x8'x12', drawings look like (3) 8'x7'x20' shelters (need the G525360 drawing to validate)

Response: See Part II of this amendment which revises Statement of Work (SOW) paragraph 3.2.1. and the Section B CLIN extended descriptions with updated dimensions.

Part II

Solicitation N00189-13-R-Z065 is hereby amended as follows:

1. Within Section C, DELETE the requirements set forth at Statement of Work (SOW) paragraph 3.2.1. in their entirety and SUBSTITUTE therefore the following:

3.2.1 Size

The enclosure shall in its shipping configuration conform to dimensions and tolerances and shall be of the size specified in the size dimensions specified within the drawings, as summarized below:

Transmit Controller Enclosure (G525358) – 8’ Width x 8’ Height x 20’ Length

Receive Controller Enclosure (G525118)– 8’ Width x 8’ Height x 12’ Length

Sounder Enclosure (G525357) – 8’ Width x 8’ Height x 20’ Length

Transmit Site Monitor (G525356) – 3 Shelters, 8 ft Width x 8 ft Height x 20 ft Length, each

Receive Site Monitor (G525359) – 4 Shelters, 8 ft Width x 8 ft Height x 20 ft Length, each

2. With the Section B Schedule of Services, the extended CLIN descriptions for the Receive and Transmit Site Monitors plus the Receive and Transmit Sounder Enclosures are hereby amended as follows to remove all references to the 8’ x 8’ x 12’ dimensions to mirror the above revisions made to SOW paragraph 3.2.1.:

SUBCLIN 0002AA

The CLIN extended description has changed

From: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 12’ length.

To: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 20’ length

SUBCLIN 0003AA

The CLIN extended description has changed

From: In accordance with the technical specifications detailed herein within Section C and technical drawing G525356:2 Shelters 8 ft width x 8 ft height x 20 ft length,1 shelter 8 ft width x 8 ft height x 12 ft length

To: In accordance with the technical specifications detailed herein within Section C and technical drawing G525356:3 Shelters: 8 ft width x 8 ft height x 20 ft length each

SUBCLIN 0005AA

The CLIN extended description has changed

From: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 12’ length.

To: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 20’ length

SUBCLIN 0006AA

The CLIN extended description has changed

From: In accordance with the technical specifications detailed herein within Section C and technical drawing G525356:2 Shelters 8 ft width x 8 ft height x 20 ft length,1 shelter 8 ft width x 8 ft height x 12 ft length

To: In accordance with the technical specifications detailed herein within Section C and technical drawing G525356:3 Shelters: 8 ft width x 8 ft height x 20 ft length each

SUBCLIN 0008AA

The CLIN extended description has changed

From: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 12’ length.

To: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 20’ length

SUBCLIN 0009AA

The CLIN extended description has changed

From: In accordance with the technical specifications detailed herein within Section C and technical drawing G525356:2 Shelters 8 ft width x 8 ft height x 20 ft length,1 shelter 8 ft width x 8 ft height x 12 ft length

To: In accordance with the technical specifications detailed herein within Section C and technical drawing G525356:3 Shelters: 8 ft width x 8 ft height x 20 ft length each .

SUBCLIN 1002AA

The CLIN extended description has changed

From: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 12’ length.

To: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 20’ length..

SUBCLIN 1003AA

The CLIN extended description has changed

From: In accordance with the technical specifications detailed herein within Section C and technical drawing G525359:3 Shelters 8 ft Width x 8 ft height x 20 ft length;1 shelter 8 ft width x 8 ft height x 12 ft length

To: In accordance with the technical specifications detailed herein within Section C and technical drawing G525359:4 Shelters: 8 ft Width x 8 ft height x 20 ft length each.

SUBCLIN 1005AA

The CLIN extended description has changed

From: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 12’ length.

To: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 20’ length..

SUBCLIN 1006AA

The CLIN extended description has changed

From: In accordance with the technical specifications detailed herein within Section C and technical drawing G525359:3 Shelters 8 ft Width x 8 ft height x 20 ft length;1 shelter 8 ft width x 8 ft height x 12 ft length

To: In accordance with the technical specifications detailed herein within Section C and technical drawing G525359:4 Shelters: 8 ft Width x 8 ft height x 20 ft length each .

SUBCLIN 1008AA

The CLIN extended description has changed

From: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 12’ length.

To: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 20’ length..

SUBCLIN 1009AA

The CLIN extended description has changed

From: In accordance with the technical specifications detailed herein within Section C and technical drawing G525359:3 Shelters 8 ft Width x 8 ft height x 20 ft length;1 shelter 8 ft width x 8 ft height x 12 ft length

To: In accordance with the technical specifications detailed herein within Section C and technical drawing G525359:4 Shelters: 8 ft Width x 8 ft height x 20 ft length each.

3. All other terms and conditions remain unchanged. The time and date for receipt of proposals remains unchanged.