A0002 N00189-13-R-Z065.doc
DOC document 46 KB Posted
- Solicitation number
- N00189-13-R-Z065
About this file
Amendments
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 13-R-Z065-0017.doc | DOC document | |
| 13-R-Z065-0016.doc | DOC document | |
| 13-R-Z065-0015.doc | DOC document | |
| N00189-13-R-Z065_Exhibit_A_SOW_thru_A0014.docx | DOCX document | |
| N00189-13-R-Z065-conformed_thru_Amend14.doc | DOC document | |
| 13-R-Z065-0014.doc | DOC document | |
| site_visit_clarification.docx | DOCX document | |
| g340557_d_all.pdf | ||
| g539689_e_all.pdf | ||
| g315826_c_all.pdf | ||
| 13-R-Z065-0013.doc | DOC document | |
| g539688_e_all.pdf | ||
| g340174_b_all 1 .pdf | ||
| NSA Northwest Directions.docx | DOCX document | |
| NSA Northwest Annex Base Visit Request Template.docx | DOCX document | |
| New Kent Directions.docx | DOCX document | |
| 13-R-Z065-0012.doc | DOC document | |
| 13-R-Z065-0011.doc | DOC document | |
| 13-R-Z065-0010.doc | DOC document | |
| 13-R-Z065-0009.doc | DOC document | |
| g525357_e_all | — | |
| A0001 N00189-13-R-Z065.doc | DOC document | |
| g525118_j_all | — | |
| A00003 13RZ065.doc | DOC document | |
| g525359_w_all.pdf | ||
| g525358_e_all | — | |
| Techncial Drawing G525356_v_all.pdf | ||
| ROTHR_Enclosures_Amend4-8.zip | ZIP file | |
| ROTHR_Enclosures_Technical.zip | ZIP file |
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
Part I
Questions received in response to Solicitation N00189-13-R-Z065:
NOTE: PART I IS PROVIDED FOR INFORMATIONAL PURPOSES ONLY AND DOES NOT BECOME PART OF THE SOLICITATION. THE CONTENT OF PART I DOES NOT AMEND THE CONTENTS OF THE SOLICITATION. SEE PART II FOR REVISIONS TO THE SOLICITATION.
1. I was able to download the drawings and think there is one missing from the site which is G525360. The drawing is needed per the #1 note on G525359 & G525356. Please consider adding to technical supplied information.
Response: The contents of G525360 consist solely of the written technical specifications for the required enclosures with some accompanying figures. The contents of G525360 have been updated and incorporated in their entirety into Solicitation N00189-13-R-Z065 as the Section C Statement of Work (SOW) Technical Specifications, and therefore furnished to offerors.
2. There are a few errors in the Solicitation. The CLIN items listing, the Transmit Sounder Enclosure and Receive Sounder Enclosure as stated as 8'x8'x12', drawings shows 8'x8'x20' (example ITEM 0005AA).
a. Transmit Sounder Enclosure and Receive Sounder Enclosure stated as 8’x8’x12’, drawings show
8’x8’x20’
b. Receive Site Monitor G525359 states (2) 8'x8'x20' and (1) 8'x8'x12', drawings look like (4) 8'x7'x20' shelters (need the G525360 drawing to validate)
c. Transmit Site Monitor G525356 states (2) 8'x8'x20' and (1) 8'x8'x12', drawings look like (3) 8'x7'x20' shelters (need the G525360 drawing to validate)
Response: See Part II of this amendment which revises Statement of Work (SOW) paragraph 3.2.1. and the Section B CLIN extended descriptions with updated dimensions.
Part II
Solicitation N00189-13-R-Z065 is hereby amended as follows:
1. Within Section C, DELETE the requirements set forth at Statement of Work (SOW) paragraph 3.2.1. in their entirety and SUBSTITUTE therefore the following:
3.2.1 Size
The enclosure shall in its shipping configuration conform to dimensions and tolerances and shall be of the size specified in the size dimensions specified within the drawings, as summarized below:
Transmit Controller Enclosure (G525358) – 8’ Width x 8’ Height x 20’ Length
Receive Controller Enclosure (G525118)– 8’ Width x 8’ Height x 12’ Length
Sounder Enclosure (G525357) – 8’ Width x 8’ Height x 20’ Length
Transmit Site Monitor (G525356) – 3 Shelters, 8 ft Width x 8 ft Height x 20 ft Length, each
Receive Site Monitor (G525359) – 4 Shelters, 8 ft Width x 8 ft Height x 20 ft Length, each
2. With the Section B Schedule of Services, the extended CLIN descriptions for the Receive and Transmit Site Monitors plus the Receive and Transmit Sounder Enclosures are hereby amended as follows to remove all references to the 8’ x 8’ x 12’ dimensions to mirror the above revisions made to SOW paragraph 3.2.1.:
SUBCLIN 0002AA
The CLIN extended description has changed
From: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 12’ length.
To: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 20’ length
SUBCLIN 0003AA
The CLIN extended description has changed
From: In accordance with the technical specifications detailed herein within Section C and technical drawing G525356:2 Shelters 8 ft width x 8 ft height x 20 ft length,1 shelter 8 ft width x 8 ft height x 12 ft length
To: In accordance with the technical specifications detailed herein within Section C and technical drawing G525356:3 Shelters: 8 ft width x 8 ft height x 20 ft length each
SUBCLIN 0005AA
The CLIN extended description has changed
From: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 12’ length.
To: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 20’ length
SUBCLIN 0006AA
The CLIN extended description has changed
From: In accordance with the technical specifications detailed herein within Section C and technical drawing G525356:2 Shelters 8 ft width x 8 ft height x 20 ft length,1 shelter 8 ft width x 8 ft height x 12 ft length
To: In accordance with the technical specifications detailed herein within Section C and technical drawing G525356:3 Shelters: 8 ft width x 8 ft height x 20 ft length each
SUBCLIN 0008AA
The CLIN extended description has changed
From: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 12’ length.
To: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 20’ length
SUBCLIN 0009AA
The CLIN extended description has changed
From: In accordance with the technical specifications detailed herein within Section C and technical drawing G525356:2 Shelters 8 ft width x 8 ft height x 20 ft length,1 shelter 8 ft width x 8 ft height x 12 ft length
To: In accordance with the technical specifications detailed herein within Section C and technical drawing G525356:3 Shelters: 8 ft width x 8 ft height x 20 ft length each .
SUBCLIN 1002AA
The CLIN extended description has changed
From: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 12’ length.
To: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 20’ length..
SUBCLIN 1003AA
The CLIN extended description has changed
From: In accordance with the technical specifications detailed herein within Section C and technical drawing G525359:3 Shelters 8 ft Width x 8 ft height x 20 ft length;1 shelter 8 ft width x 8 ft height x 12 ft length
To: In accordance with the technical specifications detailed herein within Section C and technical drawing G525359:4 Shelters: 8 ft Width x 8 ft height x 20 ft length each.
SUBCLIN 1005AA
The CLIN extended description has changed
From: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 12’ length.
To: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 20’ length..
SUBCLIN 1006AA
The CLIN extended description has changed
From: In accordance with the technical specifications detailed herein within Section C and technical drawing G525359:3 Shelters 8 ft Width x 8 ft height x 20 ft length;1 shelter 8 ft width x 8 ft height x 12 ft length
To: In accordance with the technical specifications detailed herein within Section C and technical drawing G525359:4 Shelters: 8 ft Width x 8 ft height x 20 ft length each .
SUBCLIN 1008AA
The CLIN extended description has changed
From: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 12’ length.
To: In accordance with the technical specifications detailed herein within Section C and Technical Drawing G525357: 8’ width x 8’ height x 20’ length..
SUBCLIN 1009AA
The CLIN extended description has changed
From: In accordance with the technical specifications detailed herein within Section C and technical drawing G525359:3 Shelters 8 ft Width x 8 ft height x 20 ft length;1 shelter 8 ft width x 8 ft height x 12 ft length
To: In accordance with the technical specifications detailed herein within Section C and technical drawing G525359:4 Shelters: 8 ft Width x 8 ft height x 20 ft length each.
3. All other terms and conditions remain unchanged. The time and date for receipt of proposals remains unchanged.