EX-ARDENT DISPOSAL PACKET 12-16-2021.pdf
PDF 2 MB Posted
- Solicitation number
- N0002423R4204
About this file
This reporting letter from the Director of the Naval Sea Systems Command Inactive Ships On-Site Maintenance Office provides details for the dismantlement and disposal of three Mine Countermeasure ships, Ex-ARDENT (MCM-12), Ex-SCOUT (MCM 8), and Ex-CHAMPION (MCM 4). The solicitation seeks a contractor to tow the three ships from Naval Station San Diego to a CONUS facility, where the contractor will complete dismantlement and properly dispose of all regulated materials in accordance with federal, state, and local laws. The contractor will retain any proceeds from scrap or reusable materials to offset performance costs. Enclosures provide inspection reports, surveys of hazardous materials, and photographs of Ex-ARDENT to support the ship dismantlement program.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INACTIVE SHIPS MAINTENANCE
OFFICE BREMERTON, WA
2450 WYCOFF WAY (BLDG 550)
BREMERTON, WA 98314
Ser 00/048 16 Dec 21
From: Director, Naval Sea Systems Command, Inactive Ships On-Site Maintenance Office, Bremerton, WA, 98314
To: Commander, Naval Sea Systems Command (SEA 21I), 1333 Isaac Hull Avenue SE Stop 2701, Washington Navy Yard, DC 20376-2701
Via: Director, Naval Sea Systems Command, Inactive Ships Management Office, Portsmouth, VA 23702-1009
Subj: SHIP DISMANTLEMENT PROGRAM REPORTING LETTER FOR EX-ARDENT
(MCM-12)
Ref: (a) NAVSEA INACTSHIPOFF ltr 4770 Ser N32/039 dtd 12 Jul 21
Encl:
(b) OPNAVINST 4770.5
(c) INACTSHIPOFFINST 4770.3H
(d) DoDM 4160.28-M Vl, Defense Demilitarization:
Administration Manual of 9 Aug 2017
(e) DoDM 4160.28-M V2, Defense Demilitarization:
Demilitarization Coding of 9 Mar 2017
(f) DoDM 4160.28-M V3, Defense Demilitarization:
Procedural Guidance, of 7 Jun 2011
(1) Low-Level Radioactive Material Survey and Removal Report
(2) Declassification Survey Report
(3) Demilitarization Survey Report
(4) Condition of Sale Items
(5) Liquid Load Survey Report
(6) Mercury Survey Report
(7) Rodent Free Certification
(8) Certification of Refrigerant Removal Report
(9) Equipment Containing Hydraulic Fluid
(lO)Final Walk-Through Inspection
(ll)List of Equipment Not Included in Sale
(12)Digital Photographs
1. The following information is forwarded for use in preparation of EX-ARDENT per references (a) through (d).
a. The vessel is in the custody of INACTSHIPMAINTO and is located at Pier 9, NAVAL BASE SAN DIEGO.
b. Official to be contacted by prospective bidders:
(1) Name: BRYSON, THOMAS
(2) Address: 2450 WYCOFF WAY, BLDG 550, BREMERTON, WA
98314-5250
(3) Telephone number: (360) 476-3551, (360) 801-5203 (C)
(4) Fax number: (360) 476-8665
(5) E-Mail Address: thomas.e.bryson6.civ@us.navy.mil
c. EX-ARDENT is available for inspection by appointment only, Monday through Friday, excluding holidays, between the hours of 0730 to 1500. Appointments must be made five (5) days in advance.
d. It is the opinion of the custodian that the hull of EX ARDENT is in fair condition. It is recommended that prospective bidders inspect the hull and make their own determination of the suitability of this vessel for usage or tow.
e. Vessel Characteristics are as follows:
(1) Builder: PETERSON BUILDERS
(2) Date Constructed: 22 OCT 90
(3) Dimensions: LENGTH, 224 FEET; BEAM, 39 FEET;
(4) Current Displacement: APPROX 1,267 TONS
(5) Draft: FWD 10ft 0in, MID 10ft 6in, AFT 11ft 6in
(6) Vessel Metallurgical Description: N/A WOODEN
,FIBERGLASS HULL
(7) Status of propellers: INTACT
(8) Status of rudders: LOCKED
(9) Status of anchors: INTACT
(10) Describe any issues that may affect towing: NONE
f. Supply System materials and stores were off-loaded at inactivation. No additional inventory or offload of materials was tasked.
g. Navy Curator Items have been removed from the vessel and shipped to the Navy Curator in accordance with references
(a) through (c)
h. Stripping requirements have not been completed Material of Navy interest remains onboard, and is scheduled to be removed during FY 2022.
i. The vessel has been declassified in accordance with reference (c).
j. The vessel's hull number and hull name have been obliterated in accordance with reference (c).
a. Enclosure (1) provides the removal and decontamination actions of all known low-level radioactive materials.
Include in the sale catalog that naturally occurring radiation sources, e.g., fire brick, terrazzo deck, porcelain, etc., remain on board.
b. Enclosure (2) certifies that no classified material remains aboard the vessel and that all hull markings (name and number) have been painted out. The following declassified documentation is available.
(1) Booklet of General Plans
(2) Damage Control Book and Plates
(3) Tank Conversion Tables
(4) Docking Plans
c. Enclosure (3) provides the certification of completion of demilitarization as required by the DoD Demilitarization Manual, references (d) through (f).
d. Enclosure (4) provides any remaining condition of sale requirements.
e. Enclosure (5) Water, fuel, and lube oil tanks have been pumped to (low suction/empty) as shown in enclosure (5). Include in the sales catalog a 30-45 day opportunity for bidders to verify tank soundings and to obtain fuel and lube oil samples. The amount and type of any fixed ballast remaining on board is also shown in enclosure (5).
f. Enclosure (6) provides the inventory of all equipment which contains mercury. This is a visual survey that is based on the best available knowledge of the inspector.
g. Enclosure (7) provides the rodent free certification
h. Enclosure (8) provides a list of system where refrigerant remains and/or has been removed and an inventory of those small, sealed systems remaining on board.
i. Enclosure (9) provides and inventory of remaining systems containing hydraulic fluid
j. Enclosure (10) provides the final walk-through inspection reporting letter.
k. Enclosure (11) provides the list of equipment not part of the vessel that will be removed prior to sale.
1. Enclosure (12) provides electronic digital photographs of Ex ARDENT. And will be forwarded via separate correspondence for posting on DLA website.
2. Ex-ARDENT (MCM-12) is ready in all respects for the ship dismantlement program.
<~ Thomas Bryson Director
Copy to: NAVSEA INACTSHIPOFF PORTSMOUTH VA
DATE: 24 Sept 21
RADIOLOGICAL SURVEY REPORT
SHIP/CRAFT: EX-ARDENT HULL NO: MCM-12
This report certified that a Survey for Radiological Emitters has been accomplished on board the above named Ship/Craft in accordance with INACTSHIPOFFINST
5104.1 with the following results:
X Vessel was found free of all radiological emitters and certified
RADSAFE.
__ All radiological emitters were removed and vessel is certified RADSAFE.
See attached inventory.
RADCON Survey has been accomplished on subject vessel. Radiological Emitters essential for the operation of the vessel, have been inventoried and tagged. See attached inventory.
t� Conducted By:
Isaac Cantu Marine Inspector II
JW,p Reviewed By:
Kamal Bell Quality Assurance Manager
Approved By Tim Brorson Project Manager
ENCLOSURE (1)
INACTSHIPOFFINST 5104. l E
9 SEP 16
RADIOACTIVE MATERIAL SURVEY LOG
DATE/TIME: 9/24/21 l l :45 SURVEYOR(S): ISAAC CANTU
HULL NUMBER: MCM-12 HULL NAME: ARDENT
RADIAC USED: (l) DT-640A (l) IM-253D SERIAL NUMBER: l 9443/10446
CALIBRATION DATE: 19443 EXP.06/16/22 - 10446 EXP.06/16/22
BACKGROUND RADIATION (KCPM): 368
LOCATION COMPARTMENT NAME MATERIAL
(BULLSEYE) FOUND
COMP.NO. (Y /N)
03 LVL 03 LEVEL N
03-40-0-M MAST N
03-58-0-S STACK N
02-28-0-C PILOT HOUSE N
02-28-1-D STBD WEATHER DECK FR 54 N
AFT
02-28-2-D PORTWEATHER DECK FR 54 N
AFT
02-33-1-D STARBOARD BRIDGEWING N
02-33-2-D PORT BRIDGEWING N
02-35-0-M ARMORY N
02-35-1-C CHARTROOM N
02-35-2-L CIC PASSAGEWAY N
02-38-1-Q FAN ROOM N
02-38-2-L WATCHSTANDER HEAD N
02-41-2-Q CMC OFFICE N
02-44-0-C COMBAT INFORMATION N
CENTER
02-44-1-Q FAN ROOM N
02-59-1-Q NIGHT VISION LOCKER N
02-59-2-Q LINREP LOCKER N
01-26-2-D FOC'SLE N
01-28-01-L CO STATEROOM N
01-28-0-L CO/XO STATEROOM N
01-28-1-D STARBOARD 01 LEVEL N
01-28-2-L XO STATEROOM N
01-28-2-D PORTO l LEVEL N
01-33-2-L PORT QUARTERDECK N
01-36-0-L JO HEAD N
01-37-1-A FORWARD STOREROOM N
01-37-2-L PASSAGE N
01-37-3-Q SAR LOCKER N
01-41-1-L STARBOARD STATEROOM N
01-41-2-L PORT STATEROOM N
01-41-3-A TEST EQUIPMENT LOCKER N
01-48-1-L STARBOARD QUARTERDECK N
01-48-2-Q LINEN· LOCKER N
01-48-4-Q CLEANING GEAR LOCKER N
01-50-1-L RADIO PASSAGEWAY N
01-52-0-C RADIO N
Page 2 ofS
NOMENCLATURE SOURCE
(COMPONENT, INTENSITY
MODEL, (CPM)
ISOTOPE)
NIA 238
N/A 181 N/A 237 N/A 119 N/A 181
N/A 277
N/A 184 N/A 314 N/A 121 N/A 145 N/A 146 N/A 153 N/A 114 N/A 137 N/A 142
N/A 142 N/A 151 N/A 281 N/A 282 N/A 92.9 N/A 146 N/A 179 N/A 86.3 N/A 193 N/A 181 N/A 117 N/A 125 N/A 116 N/A 120 N/A 122 N/A 113 N/A 127 N/A 118 N/A 94 N/A 147 N/A 116 N/A 102
ENCLOSURE (1)
RADIOACTIVE MATERIAL SURVEY LOG
DATE/TIME: 9/24/21 l l :45 SURVEYOR(S): ISAAC CANTU
HULL NUMBER: MCM-12 HULL NAME: ARDENT
RADIAC USED: (l) DT-640A (l) IM-253D SERIAL NUMBER: l 9443/10446
CALIBRATION DATE: 19443 EXP.06/16/22 - 10446 EXP.06/16/22
BACKGROUND RADIATION (KCPM): 368
INACTSHIPOFFINST 5104. l E
9 SEP 16
LOCATION COMPARTMENT NAME MATERIAL J\OMENCLATURE SOURCE
(BULLSEYE) FOUND (COMPONENT, INTENSITY
COMP.NO. (YIN) MODEL, (CPM)
ISOTOPE)
01-52-1-Q EKMS VAULT N N/A 112
01-54-1-Q STARBOARD AFFF STATION N N/A 112
01-57-1-Q FAN ROOM N N/A 142
01-57-2-C IC GYRO N N/A 167
01-66-1-Q FILTER CLEANING SHOP N N/A 201
01-69-2-Q FAN ROOM N N/A 168
01-69-4-Q BOAT GEAR LOCKER N N/A 156
01-72-1-Q MNS SHOP N N/A 109
01-72-2-D PORT02 ½ N N/A 227
01-76-2-Q 400 HZ N N/A 189
01-77-1-Q EOD N N/A 97.8
01-82-0-M SMALL ARMS MAGAZINE N N/A 135
01-82-1-M DESTRUCTIVE MAGAZINE N N/A 86.4
01-82-2-Q PORT AFFF ATATION N N/A 171
01-86-0-D AFT 01 LEVEL N N/A 191
01-41-0-L JO ANNEX N N/A 93.5
1-0-0-A FORWARD BOS'N LOCKER N N/A 98.2
1-5-0-L FORWARD PASSAGEWAY N N/A 127
1-5-2-Q REPAIR II ANNEX N N/A 94.5
1-7-1-Q REPAIR II N N/A 120
1-7-2-A CBR STOREROOM N N/A 126
1-11-2-A CANNED FOOD STORAGE N N/A 107
l-14-0-L SONAR PASSAGEWAY N N/A 192
1-14-1-L 9 MAN BERTHING N N/A 102
1-14-2-L 15 MAN BERTHING N N/A 122
1-21-1-Q SONAR FAN ROOM N N/A 96.6
1-23-1-Q SONAR MAINTENANCE N N/A 97.9
ROOM
l-28-0-L CPO PASSAGEWAY N N/A 122
1-28-1-L 15 MAN HEAD N N/A 134
l-28-2-L 40 MAN HEAD N N/A 143
1-28-3-L CPO HEAD N N/A 125
l-33-1-L CPO BERTHING N N/A 142 l -33-2-L MEDICAL TREATMENT ROOM N N/A 182 l -35-2-L MEDICAL PASSAGEWAY N N/A 111
1-38-2-A MEDICAL STOREROOM N N/A 128
l-41-0-L MESS DECK N N/A 122 l-41-1-Q CLEANING GEAR LOCKER N N/A 128 l-41-2-L WARDROOM N N/A 161
1-41-3-Q RELIGIOUS LOCKER N N/A 97
Page 3 of5 ENCLOSURE (I)
RADIOACTIVE MATERIAL SURVEY LOG
DATE/TIME: 9/24/21 11 :45 SURVEYOR(S): ISAAC CANTU
HULL NUMBER: MCM-12 HULL NAME: ARDENT
RADIAC USED: (1) DT-640A (1) IM-253D SERIAL NUMBER: 19443/10446
CALIBRATION DATE: 19443 EXP.06/16/22-10446 EXP.06/16/22
BACKGROUND RADIATION (KCPM): 368
INACTSHIPOFFINST 5104.1 E
9 SEP I 6
LOCATION COMPARTMENT NAME MATERIAL NOMENCLATURE SOURCE
(BULLSEYE) FOUND (COMPONENT, INTENSITY
COMP.NO. (Y /N) MODEL, (CPM)
ISOTOPE)
1-44-1-Q WATER HEATER SPACE N N/A 106
1-45-2-Q GALLEY N N/A 171
1-56-2-L CPO MESS N N/A 140
1-59-1-L AMR VESTIBULE N N/A 102
1-59-3-Q SHIP'S OFFICE N N/A 112
1-63-2-L REEFER DECKS N N/A 95.8
1-63-4-A FREEZE STOREROOM N N/A 121
1-66-2-A CHILL STOREROOM N N/A 171
1-68-2-A DRY PROVISION N N/A 93
STOREROOM
1-70-1-Q SUPPLY OFFICE N N/A 99.6
1-71-2-Q LAUNDRY N N/A 161
1-72-0-E REEFER MACHINERY ROOM N N/A 76.1
1-75-2-Q R&A LOCKER N N/A 152
1-76-1-Q GENERAL WORKSHOP N N/A 135
1-77-0-C CENTRAL CONTROL STATION N N/A 82.2
1-77-2-Q OIL LAB N N/A 117
1-77-4-Q R&A REENTRY LOCKER N N/A 264
1-78-1-L MMR VESTIBULE N N/A 120
1-78-1-L ENG PASSAGEWAY N N/A 98.5
1-80-2-Q LOG ROOM N N/A 109
1-83-1-L PASSAGE N N/A 110
1-86-1-L FANTAIL N N/A 182
1-87-1-L DOG HOUSE N N/A 105
1-87-2-L DECON PASSAGEWAY N N/A 94.5
1-87-4-Q R&A ANNEX N N/A 151
1-89-2-L AFT DECON STATION N N/A 176
1-89-4-Q PLASTIC STORAGE N N/A 136
2-0-0-A FLAM STOREROOM N N/A 118
2-14-0-L CREWS REC N N/A 71.2
2-18-2-L 6 MAN BERTHING N N/A 81.6
2-23-0-Q GATX N N/A 151
2-23-2-Q FAN ROOM N N/A 148
2-28-0-L 40 MAN BERTHING N N/A 193
2-86-0-E UCHS N N/A 102
2-91-0-A SUPPLY STOREROOM N N/A 96
2-91-2-A PASSAGE N N/A 110
2-99-0-A SWEEP GEAR N NIA 133
2-104-1-E OILY WATER SEP ARA TOR N NIA 72
ROOM
Page 4 ofS ENCLOSURE (1)
INACTSHIPOFFINST 51 04. l E
9 SEP 16
RADIOAC TI VE MATERIAL SURVEY LOG
DATE/TIM E: 9 / 24/21 11 :45 SURVEYO R(S) : ISAAC CANTU
HULL NUMBER: MCM- 12 HULL NAM E: ARDENT
RAD/AC USED: (l) DT-640A (l) IM-253D SERIAL NUMBER: l 9443/10446
C ALIBRATIO N DATE: 19443 EXP.06/16/22 - 10446 EXP.06/1 6/22
BACKG ROUND RADIATION (KCPM): 368
LOCATION COMPARTMENT NAME MATERIAL
(BULLSEYE) FOUND
COMP. NO. (Y /N)
2-107-0-E AFT STEERING N
3-14-0-E BOW THRUSTER N
3-28-0-E PUMP ROOM N
3-41-0-E AMR N
3-63-0-E MMR N
l -63-01-L PASSAGE N
01-41-01 -L PASSAGE N
02-72- 1-D STBD 02 ½ N
NOMENCLATURE SOURCE
(COMPONENT, INTENSITY
MODEL, (CPM)
ISOTOPE)
N/A 122 N/A 109 N/A 180 N/A 112 N/A 78.3 N/ A 188 N/A 190 N/A 239
RSO/ARSO (Print): ~ kr svyfrth-, "je, \ \
RSO/ARSO Signotu,e, ~.= DATE: _ _ 10_/ _1:s--+-f-~ ...,__I _
Page 5 of 5 ENCLOSURE (1)
DATE: 23 Sept 21
DECLASSIFICATION SURVEY REPORT
SHIP/CRAFT: EX-ARDENT HULL NO: MCM-12
THIS REPORT CERTIFIES THAT A DECLASSIFICATION INSPECTION HAS
BEEN ACCOMPLISHED ONBOARD THE ABOVE NAMED SHIP/CRAFT
PER INACTSHIPOFFINST 4770.3H WITH THE FOLLOWING RESULTS:
X DECLASSIFICATION SURVEY ACCOMPLISHED AND NO
CLASSIFIED MATERIAL WAS FOUND TO BE ONBOARD.
Conducted By:
Isaac Cantu
Marine Inspector
IJ!h1.� Reviewed By:
Kamal Bell
Quality Assurance Manager
PAGE l OF l
Approved By
Tim Brorson
ENCLOSURE (2)
DATE: 30 Sept 21
DEMILITARIZATION SURVEY REPORT
SHIP/CRAFT: EX- ARDENT HULL NO: MCM- 12
DEMILITARIZATION COMPLETE FOR THIS VESSEL:
HULL NAME AND NUMBERS HA VE BEEN OBLITERATED.
1Y12v-- Reviewed By:
Kamal Bell
Quality Assurance Manager
Approved By
Tim Brorson
ENCLOSURE (3)
DATE: 12 Oct 21
CONDITION OF SALE
SHIP/CRAFT: EX- _A_RD_E_N_T ____ HULL NO: MCM-12
No condition of sale to report per INACTSHIPOFFINST 4770.3H.
Kamal Bell
Quality Assurance Manager
1�� Timothy Brorson
ENCLOSURE (4)
DATE: 16 Dec 21
LIQUID LOAD SURVEY REPORT
SHIP/CRAFT: EX- ARDENT HULL NO.:MCM 12
This report certifies that a liquid load survey has been accomplished on board the above named ship/craft with the following information pertaining:
1. Complete liquid load Survey see attached
Reviewed By:
Kamal Bell
Quality Assurance Manager
Approved By Tim Brorson
Project Manager
Enclosure (5)
TANK # LEVEL QUANTITY
UNIT OF
MEASURE FLUID DESCRIPTION
3-29-1-F 0'0" 0 GALLONS EMPTY
3-29-2-F 0'0" 0 GALLONS EMPTY
3-34-1-F 0'0" 0 GALLONS EMPTY
3-34-2-F 0'0" 0 GALLONS EMPTY
0 GALLONS
TANK # LEVEL QUANTITY
UNIT OF
MEASURE FLUID DESCRIPTION
3-77-2-F 0'0" 0 GALLONS EMPTY
3-84-1-F 0'0" 0 GALLONS EMPTY
3-85-2-F 0'0" 0 GALLONS EMPTY
0 GALLONS
TANK # LEVEL QUANTITY
UNIT OF
MEASURE FLUID DESCRIPTION
2-27-2-F 0'0" 0 GALLONS EMPTY
2-27-4-F 0'0" 0 GALLONS EMPTY
2-87-1-F 0'0" 0 GALLONS EMPTY
2-87-2-F 0'0" 0 GALLONS EMPTY
2-87-3-F 0'0" 0 GALLONS EMPTY
2-87-4-F 0'0" 0 GALLONS EMPTY
0 GALLONS
TANK # LEVEL QUANTITY
UNIT OF
MEASURE
3-43-1-W 8'6.5" 2050 GALLONS
3-43-2-W 0'0" 0 GALLONS
FLUID DESCRIPTION
FRESH WATER
EMPTY
2050 GALLONS
EX-ARDENT (MCM-12)
LIQUID LOAD LIST
FINAL
FUEL STORAGE
FUEL OIL SERVICE TANKS
POTABLE WATER
TOTAL
TOTAL
TOTAL
LUBE OIL STORAGE AND SETTLING
TOTAL
PAGE 2 OF 3 Enclosure (5)
TANK # LEVEL QUANTITY
UNIT OF
MEASURE FLUID DESCRIPTION
3-61-1-F 0'0" 0 GALLONS EMPTY
3-61-2-F 0'0" 0 GALLONS EMPTY
3-67-1-F 0'0" 0 GALLONS EMPTY
3-67-2-F 0'0" 0 GALLONS EMPTY
2-104-1-F 0'0" 0 GALLONS EMPTY
0 GALLONS
TANK # LEVEL QUANTITY
UNIT OF
MEASURE FLUID DESCRIPTION
3-81-1-F 0'0" 0 GALLONS EMPTY
3-81-2-F 0'0" 0 GALLONS EMPTY
0 GALLONS
TOTAL 2050
TOTAL: 2050
FRESH
WATER 2050
SALT WATER 0
TOTAL
WASTE OIL
HYDRAULIC OIL
TOTAL
PAGE 3 OF 3 Enclosure (5)
DATE: 27 Sept 21
MERCURY SURVEY REPORT
SHIP/CRAFT: EX-ARDENT HULL NO.: MCM-12
This report certifies that a survey for Mercury containing components has been accomplished onboard the above named ship/craft with the following results:
NIA
X
X
Conducted By:
Isaac Cantu Marine Inspector
Mercury Survey was accomplished and no mercury containing components were found.
Mercury Survey was accomplished and mercury containing components found. See attached inventory list:
There are Yes X /No __ 1,144 fluorescent light R b remaining on this craft.
Reviewed By:
Kamal Bell Quality Assurance Manager
Approved By Tim Brorson Project Manager
ENCLOSURE (6)
~ rr
Ex-Ardent (MCM 12) Mercury Inventory
Sept 13-24,2021
1,2 heat sensor 2 0.6 01-28-01-L CO STATEROOM
3,4 heat sensor 2 0.6 01-28-2-L XO STATEROOM
5,6 heat sensor 2 0.6 01-37-1-A FORWARD STOREROOM
7,8 heat sensor 2 0.6 01-41-1-L STARBOARD STATEROOM
9, I 0 heat sensor 2 0.6 01-41-2-L PORT STATEROOM
11, 12 heat sensor 2 0.6 01-41-3-A TEST EQUIPMENT LOCKER
13,14,15 heat sensor 3 0.6 01-52-0-C RADIO
16, 17 heat sensor 2 0.6 01-54-1-Q STARBOARD AFFF STATION
18, 19 heat sensor 2 0.6 01-57-1-Q FAN ROOM
20,21 heat sensor 2 0.6 01-57-2-C IC GYRO
22,23 heat sensor 2 0.6 01-66-1-Q FILTER CLEANING SHOP 24 heat sensor I 0.6 01-69-2-Q FAN ROOM
25,26 heat sensor 2 0.6 01-72-1-Q MNS SHOP
27 heat sensor I 0.6 01-76-2-Q 400 HZ 28,29 heat sensor 2 0.6 01-77-1-Q EOD 30,31 heat sensor 2 0.6 01-82-0-M SMALL ARMS MAGAZINE
32,33 heat sensor 2 0.6 01-82-1-M DESTRUCTIVE MAGAZINE
34,35 heat sensor -2 0.6 01-82-2-Q PORT AFFF STATION
36,37 heat sensor 2 0.6 02-28-0-C PILOT HOUSE
38,39 heat sensor 2 0.6 02-35-0-M ARMORY
40,41 heat sensor 2 0.6 02-35-1-C CHART ROOM
42,43 heat sensor 2 0.6 02-38-1-Q FAN ROOM
44,45 heat sensor 2 0.6 02-41-2-Q CMC OFFICE
46,47,48, heat sensor 0.6 02-44-0-C
COMBAT INFORMATION
49,50 CENTER
51,52 heat sensor 2 0.6 02-44-1-Q FAN ROOM
53,54 heat sensor 2 0.6 1-0-0-A FORWARD BOS'N LOCKER
55 heat sensor I 0.6 1-11-2-A CANNED FOOD STORAGE
56,57 heat sensor 2 0.6 1-14-1-L 9 MAN BERTHING
58,59,60 heat sensor 3 0.6 1-14-2-L 15 MAN BERTHING
0.6 1-23-1-Q
SONAR MAINTENANCE
61 heat sensor
ROOM
62 heat sensor I 0.6 1-33-1-L CPO BERTHING
0.6 1-33-2-L
MEDICAL TREATMENT
63,64 heat sensor 2
ROOM
65 heat sensor I 0.6 1-35-2-L MEDICAL PASSAGEWAY
66,67,68, heat sensor 4 0.6 1-41-0-L MESS DECKS
70,71 heat sensor 2 0.6 1-41-2-L WARDROOM
72,73 heat sensor 2 0.6 1-41-3-Q RELIGIOUS LOCKER
74,75,76 heat sensor 3 0.6 1-45-2-Q GALLEY
PAGE 2 OF4 ENCLOSURE (6)
Sept 13-24,2021
77,78 heat sensor 2 0.6 1-56-2-L CPO MESS
79,80 heat sensor 2 0.6 1-59-3-Q SHIP'S OFFICE
81,82 heat sensor 0.6 1-68-2-A
DRY PROVISION
STOREROOM
83,84 heat sensor 2 0.6 1-70-1-Q SUPPLY OFFICE
85,86 heat sensor 2 0.6 1-71-2-Q LAUNDRY
87, heat sensor I 0.6 1-7-1-Q REPAIR II
88,89 heat sensor 2 0.6 1-72-0-E REEFER MACHINERY ROOM
90,91 heat sensor 2 0.6 1-7-2-A CBR STOREROOM
92,93 heat sensor 2 0.6 1-76-1-Q GENERAL WORKSHOP
94 heat sensor I 0.6 1-77-0-C CENTRAL CONTROL STATION
95,96 heat sensor 2 0.6 1-77-2-Q OIL LAB
97,98 heat sensor 2 0.6 1-80-2-Q LOG ROOM
99,100 heat sensor 2 0.6 2-0-0-A FLAM STOREROOM
101,102 heat sensor 2 0.6 2-14-0-L CREWS REC
103,104 heat sensor 2 0.6 2-18-2-L 6 MAN BERTHING
105,106 heat sensor 2 0.6 2-23-0-Q GATX
107,108 heat sensor 2 0.6 2-23-2-Q FAN ROOM
109,110, 111, I 12, heat sensor 8 0.6 2-28-0-L 40 MAN BERTHING
113,114, 115,116
117 heat sensor 1 0.6 2-86-0-E UCHS
118, 119, heat sensor 4 0.6 2-91-0-A SUPPLY STOREROOM
120, 121
122, 123, heat sensor 3 0.6 2-99-0-A SWEEP GEAR
125, 126 heat sensor 2 0.6 2-104-1-E
OILY WATER SEPARATOR
ROOM
127, 128, heat sensor 4 0.6 2-107-0-E AFT STEERING
129, 130
131, 132 heat sensor 2 0.6 3-14-0-E BOW THRUSTER
133, 134 heat sensor 2 0.6 3-28-0-E PUMP ROOM
135, 136, 137, 138, 139, 140, heat sensor 10 0.6 3-41-0-E AMR
141, 142, 143, 144
145, 146, 147, 148, 149, 150, heat sensor IO 0.6 3-63-0-E MMR
151, 152, 153, 154
PAGE 3 OF4 ENCLOSURE (6)
Sept 13-24, 2021
Floruescent bulbs NIA 1,144 All Spaces NIA
Quantity Heat Sensors 154
Weight Heat Sensors 92.4 lbs
Total Florescent Bulbs 1,144 total
PAGE 4 OF 4 ENCLOSURE (6)
DATE: 27 Sept 21
RODENT / INSECT FREE INSPECTION REPORT
SHIP/CRAFT: EX-ARDENT HULL NO: MCM-12
This report certifies that a Rodent/ Insect Free survey has been accomplished onboard the above named ship/craft with the following results:
No rodent/ insects or evidence of rodent I insect were found.
Verified By:
Isaac Cantu Marine Inspector II
Approved By:
Tim Brorson Project Manager
1 OF2
QL1h:
Reviewed By:
Kamal Bell
Quality Assurance Manager
ENCLOSURE (7)
DATE: 30 Sept 2021
REFRIGERANT SURVEY REPORT
SHIP/CRAFT: EX-ARDENT HULL NO: MCM-12
This report certifies that a Refrigerant Survey has been accomplished onboard the above named Ship/Craft with the following results:
X
X
All major sources of Refrigerant were removed from ship during inactivation.
An inventory was conducted listing all lrnown equipment that contains
Refrigerant, Small units i.e. scuttlebutts, ice makers, juice machines etc.
See attached list.
A survey was conducted, no Refrigerant containing equipment was found.
Conducted By:
Isaac Cantu Marine Inspector
Reviewed By:
Kamal Bell Quality Assurance Manager
Approved By TimBrorson
PAGE 1 OF 3 ENCLOSURE (8)
7J Gl m w
'I
REFRIGERANTSURVEY
SHIP: USS ARDENT (MCM 12)
COMPARTMENT # FRAME EQUIPMENT
GALLEY 1-45-2-Q 1-53-2 COUNIER REEFER
GALLEY .1-45-2-Q .1-53-2 GALLEY REEFER
MESSDECKS 1-41-0-L 1-63-1 GALLEY REEFER
AMR 3-41-0-E 3-63-1 lAC
AMR 3-41-0-E 3-63-1 2AC
MNSSHOP 0l-72-l0Q 01-76-2 MNSREEFER
MAINBDS 1-33-2-L 1-35-4 MEDREEFER
REEFERROOM 1-72-0-E 1-75-1 I REEFER
REEFER ROOM 1-72-0-E 1-75-1 2REEFER
CHENG: .,,.,,.---:_ - 1.._.
Lu fMnfQY}
MANUFACTOR
COPELAND
COPELAND
COPELAND
YORK
YORK
TECUMSEH
· TECUMSEH
YORK
YORK
DATE: 05AUG2020
MODEL REFRIG.
AFEBC3E-1AA-103 R-134A
AFE208E-1AA-103 R-134A
AFE27C3-1AA-959 R-134A
RN62C R-134A
RN62C R-134A
AE-1023-E R-134A
AE-1023-E R-134A
FN22A R-134A
FN22A R-134A
CO: _\
V.?-' I
QUANTITY REMARKs
2LBS REMOVED
2LBS REMOVED
2LBS REMOVED
35LBS REMOVED
40LBS REMOVED
2LBS REMOVED
2LBS REMOVED
50LBS REMOVED
35LBS REMOVED
E N
C L O
SU
R
E (8)
SMALL SEALED REFRIGERANT CONTAINING SYSTEM ONBOARD
SHIP: USS ARDENT MCM 12 DATE: 23 Sept 21
COMPARTMENT # FRAME EQUIPMENT MANUFACTOR MODEL REFRIG. QUANTITY REMARKS
MGM
ER-4-1366
1-33-2-L 1 40 REFRIGERATOR EQUIPMENT
HNM
R-134A 1
CORP.
1-45-2-Q 2 50 COLDWELL COSPOLICH TRl0AG R-134A 1
1-45-2-Q 3/4 48 REFRIGERATOR/FREEZER COSPOLICH UCRI0FI0 R-134A 2
1-41-0-Q 5 50 ICE MACHINE CORNELIUS R-134A 1
1-41-0-L 6 55
MESS DECK
MGR
ER-10-
R-134A 1
REFRIGERATOR 1368HNM
PAGE 3 OF 3 ENCLOSURE (8)
Intact
Intact Intact
Intact Intact
DATE: 28 Sept 21
HYDRAULIC SURVEY REPORT
SHIP/CRAFT: EX-ARDENT HULL NO.: MCM-12
This report certifies that a survey for Hydraulic equipment has been accomplished onboard the above named ship/craft with the following results:
X No Information available from ship inactivation. Hydraulic oil is presumed to be present in aft steering, in Port and Starboard CPP tanks, anchor windlass, and various other deck equipment such as Deck crane, cable reels, and boat davits.
i��- 1-n;viewed'By:
Approved By Kamal Bell Quality Assurance Manager
Tim Brorson Project Manager
ENCLOSURE (9)
INACTIVE SHIPS MAINTENANCE
OFFICE BREMERTON, WA
2450 WYCOFF WAY (BLDG 550)
BREMERTON, WA 98314
FINAL WALK-THROUGH INSPECTION REPORTING LETTER
Ser 00 / 45
16 Dec 21
From: Director, Naval Sea Systems Command, Inactive Ships On
Site Maintenance Office, Bremerton, WA, 98314
To: Director, Naval Sea Systems Command, Inactive Ships
Management Office, Portsmouth, VA 23702-1009
Subj: FINAL WALK-THROUGH INSPECTION OF EX-ARDENT (MCM-12)
Ref: (a) OPNAVINST 4770.5
(b) INACTSHIPOFFINST 4770.3H
(c) NAVSEA INACTSHIPOFF ltr 4770 Ser N32/039dtd 12
July 2021
Encl: (11) Inventory of industrial plant equipment (IPE) and other equipment and material of value remaining on board EX-ARDENT (MCM-12) as of
28 Sept 21
1. A final walk-through inspection of subject vessel was conducted by ALAN PRICE in accordance with references (a), (b) ,and(c). All disposal procedures have been completed in accordance with applicable instructions and guidelines. Stripping requirements have not been completed Material of Navy interest remains onboard, and is scheduled to be removed during FY 2022.
Director
Enclosure (10)
DATE: 12 Oct 21
EQUIPMENT NOT INCLUDED IN SALE
SHIP/CRAFT: EX- �A.;;...;..;RD;;;._,;;E;;;.;;_N,;;_,;_T ____ HULL NO: MCM-12
1. Any equipment provided by Naval Base San Diego/ INACTSHIPMAINTO Bremerton including but not limited to gangways, shore power components, alarm system, fenders, mooring lines are not included in the sale of this vessel.
2. There is no Industrial Plant Equipment (IPE) of any value to the
Government remaining on board.
3. There is no other equipment or material of any value to the Government remaining on board ..
Kamal Bell
Quality Assurance Manager
�rfk Timothy Brorson
ENCLOSURE {11)
&-·· ls:rii ... � - - - .
EX-ARDENT PHOTOS
PAGE 1 OF 1 ENCLOSURE (12)
Blank Page
File details come from the government source that posted it. Updated .