Att 1 Spec Response Matrix
| ATTACHMENT 2 |
| OSR 25UB & 30BP |
| SPECIFICATION RESPONSE MATRIX |
NOTES & INSTRUCTIONS:
Offerors to submit Attachment 2 with response for parameters identified in the Specification (See Section J).
1. Where specific parameters or other technical information are required in the Specification (indicated by red text in the Specification), Offerors shall fill in the specific parameters/information for their proposed design for each boat configuration (as applicable) in this attachment and include supporting data in Vol I as directed. At bottom Offerors shall respond with 'Comply' to indicate their design meets all Specification requirements; or 'Comply w/Exceptions' to indicate disagreement with any specific section of the Specification.
2. A response of 'Comply w/Exceptions' shall be accompanied by amplifying notes in the 'Offeror's Notes' section at bottom, providing rationale for any exceptions. Each exception shall list the Specification section, the specific rationale for non-compliance with the section, and a proposed alternative approach. Any proposed alternative approach must meet the minimum requirement of the Specification to the Government's satisfaction. Description of Offeror's alternative approach shall include the detailed approach to achieving the minimum Specification requirement; applicable material specifications, make and model numbers for all parts/components; compliance with any requisite commercial or military standard, or associated “best practice”; and shall include any supporting product performance, test data, or other empirical evidence for the proposed product or service capability where applicable. The Government reserves the right to reject (without discussion) any proposed alternative which is incomplete or fails to meet minimum requirements of the Specification.
3. A response is required for each Specification section identified herein. The Government reserves the right to evaluate incomplete responses as non-compliant with the Specification and unacceptable for Factor 1 (Technical Approach).
| Specification Item | Specification Parameter | Offeror Response for 25UB | |
| (See Note 1) | Offeror Response for 30BP |
(See Note 1)
| 070-1-UB/-BP | Enter Length Overall (LOA): xx.xx feet (ft) | ||
| 070-1-UB/-BP | Enter Hull Length (Lhull): xx.xx ft | ||
| 070-1-UB/-BP | Enter Beam Overall (BOA): xx.x ft | ||
| 070-1-UB/-BP | Enter Chine Beam: xx.x ft | ||
| 070-1-UB/-BP | Enter Height, Keel to Fixed Structure: xx.x ft | ||
| 070-1-UB/-BP | Enter Height, Keel to Moveable Structure: xx.x ft | ||
| 070-1-UB/-BP | Enter Height, Gunwale top to deck (min - max): xx.x – xx.x ft | ||
| 070-1-UB/-BP | Enter Height, Freeboard – Gunwale top to waterline (min – max): xx.x – xx.x ft | ||
| 070-1-UB/-BP | Enter Height on trailer when rigged for transport: xx.x ft | ||
| 070-1-UB/-BP | Enter Width on trailer when rigged for transport: xx.x ft | ||
| 070-1-UB/-BP | Enter Forward Cargo Deck Space (Length from bow door sill to wheelhouse x Width): xx.x ft x xx.x ft | N/A | |
| 070-1-UB/-BP | Enter Deadrise: xx degrees (state if constant or variable) | ||
| 070-1-UB/-BP | Enter Total Installed Fuel Capacity: xxx gallons | ||
| 070-1-UB/-BP | Enter Full Load Weight (as defined in Section 070-5-xx): x,xxx lbs incl x% margin | ||
| 070-1-UB/-BP | Enter Longitudinal Center of Gravity (LCG) in Full Load: xx.x ft forward of transom/keel intersect | ||
| 070-1-UB/-BP | Enter Draft: x.x ft at Full Load | ||
| 070-1-UB/-BP | Enter Cruise Speed (at xx,xxx engine RPM): xx knots (kts) at Full Load in calm water | ||
| 070-1-UB/-BP | Enter Sprint Speed (at wide open throttle): xx kts at Full Load in calm water | ||
| 070-1-UB/-BP | Enter Projected Static Bollard Pull : x,xxx lbs in Minimum Payload condition (for 25UB); x,xxx lbs in Minimum Payload condition minus 2,500 lb (for 30BP). | ||
| 070-2-UB/-BP | Enter list of submitted drawings describing the proposed boat. | ||
| 083-1-UB/-BP | Initial Spares List - Verify Attachment 2 submitted in Vol II for each configuration. | ||
| 084-4-UB/-BP | Enter Trailer Make & Model (Aluminum); confirm trailer spec sheet submitted in Vol I. | ||
| 084-4-UB/-BP | Enter Trailer Make & Model (Galvanized Steel); confirm trailer spec sheet submitted in Vol I. | ||
| 100 | General Requirements for Hull Structure - Verify that a description of the builder's welding qualification program is included in Vol I. | ||
| 236-1a-UB | Outboard Engines - Twin Yamaha 115's - Verify speeds and static bollard pull required in Spec can be achieved on proposed boat using specified engines. | N/A | |
| 236-1b-UB | Outboard Engines - Twin Evinrude 115's - Verify speeds and static bollard pull required in Spec can be achieved on proposed boat using specified engines. | N/A | |
| 236-1c-UB | Outboard Engines - Twin Mercury 115's - Verify speeds and static bollard pull required in Spec can be achieved on proposed boat using specified engines. | N/A | |
| 236-1d-UB | Outboard Engines - Twin Honda 115's - Verify speeds and static bollard pull required in Spec can be achieved on proposed boat using specified engines. | N/A | |
| 236-1e-BP | Outboard Engines - Twin Yamaha 150's - Verify speeds and static bollard pull required in Spec can be achieved on proposed boat using specified engines. | N/A | |
| 236-1f-BP | Outboard Engines - Twin Evinrude 150's - Verify speeds and static bollard pull required in Spec can be achieved on proposed boat using specified engines. | N/A | |
| 236-1g-BP | Outboard Engines - Twin Mercury 150's - Verify speeds and static bollard pull required in Spec can be achieved on proposed boat using specified engines. | N/A | |
| 236-1h-BP | Outboard Engines - Twin Honda 150's - Verify speeds and static bollard pull required in Spec can be achieved on proposed boat using specified engines. | N/A | |
| 529-2 | Electric Bilge Pump - Enter specific bilge pump quantity and locations. | ||
| All | OSR 25UB / 30BP Specification - Enter "Comply"; or enter "Comply w/Exceptions" AND provide rationale for exceptions in notes below. | ||
| Offeror's Notes: |
&12RFP N00024-15-R-22XX Ver 23 Nov 14
Example Response
| ATTACHMENT 1 |
| OSR 25UB & 30BP |
| SPECIFICATION RESPONSE MATRIX - EXAMPLE RESPONSE |
See below for partial example responses.
| Specification Item | Specification Parameter | Offeror Response for 25UB | |
| (See Note 1) | Offeror Response for 30BP |
(See Note 1)
| 070-1-UB/-BP | Enter Length Overall (LOA): xx.xx feet (ft) | 27.5 ft | 32.3 ft |
| 070-1-UB/-BP | Enter Hull Length (Lhull): xx.xx ft | 24.9 ft | 30.1 ft |
| 070-1-UB/-BP | Enter Beam Overall (BOA): xx.x ft | 8.5 ft | 10.0 ft |
| 070-1-UB/-BP | Enter Chine Beam: xx.x ft | 8.3 ft | 9.8 ft |
| 070-1-UB/-BP | Enter Forward Cargo Deck Space (Length from bow door sill to wheelhouse x Width): xx.x ft x xx.x ft | N/A | 18.0 ft x 8.75 ft |
| 070-1-UB/-BP | Enter Cruise Speed (at xx,xxx engine RPM): xx knots (kts) at Full Load in calm water | 22 kt at 5,000 rpm | 24 kt at 5,100 rpm |
| 070-3-UB/-BP | Enter list of submitted drawings describing the proposed boat. | 100-123456 Gen'l Arr 25UB |
100-123457 Transport 25UB (Continue per Sect L) 100-123456 Gen'l Arr 30BP 100-123457 Transport 30BP (Continue per Sect L)
| 083-1-UB/-BP | Initial Spares List - Verify Attachment 2 submitted in Vol II for each configuration. | Verified | Verified |
| 084-4-UB/-BP | Enter Trailer Make & Model (Aluminum); confirm trailer spec sheet submitted in Vol I. | TrailerMart Model 25UB-AL; Spec Sheet in Vol I | TrailerMart Model 30BP-AL; Spec Sheet in Vol I |
| 236-1a-UB | Outboard Engines - Twin Yamaha 115's - Verify speeds and static bollard pull required in Spec can be achieved on proposed boat using specified engines. | Verified | N/A |
| All | OSR 25UB / 30BP Specification - Enter "Comply"; or enter "Comply w/Exceptions" AND provide rationale for exceptions in notes below. | Comply w/Exceptions | Comply w/Exceptions |
| Offeror's Notes: | |||
| 313-3: Exception: Builder has no local distributor for Blue Seas voltmeters. Builder proposes a BrandX Model xxx123 voltmeter in lieu of a Blue Seas voltmeter specified. A catalog sheet for BrandX Model xxx123 is included in Vol I. Builder has used BrandX voltmeters in 300 boats in similar applications. |