OP #1086043
Repair (Sustain) Child Development Center, B1994 Base Civil Engineering Division Hanscom AFB, Massachusetts 1/15/2025 - Part 6 - 2 of 4
Repair (Sustain) Child Development Center MRXD 17-0051 Hanscom Air Force Base, MA OP 1086043
Rpr (Sustain) Child Development Center, B1994
MRXD 17-0051
OP 1086043
Hanscom Air Force Base, MA
Design-Build RFP Table of Contents
This project scope of work consists of the requirements of all documents included in the 6 Parts of this Design-Build RFP. The italics text provided for each part provides a general overview of the contents of each part. The contractor is responsible for a review of each part of the Design-Build RFP in detail.
PART 1 – PROPOSAL FORMS & DOCUMENTS
Part 1 includes the offeror instructions, solicitation requirements and required bid documents.
00100 Solicitation Form 1442
00201 Instructions to Proposers
00210 Evaluation Factors to Award
00600 Representations and Certifications
00710 Model Contract
00830 Davis-Bacon Wage Rates
PART 2 – GENERAL REQUIREMENTS
Part 2 includes Division 01 specifications. The Division 01 sections include a general summary of work as well as administrative, procedural, design and construction submission, and closeout requirements for the project.
This Division 01 specifications provide references to additional design and construction requirements to other sections of the DB RFP.The Contractor is responsible for a detailed review of the remainder of the RFP for additional contract requirements and guidance included in the scope the work. Request any required forms from the government.
01 11 00 SUMMARY OF WORK
01 14 00 WORK RESTRICTIONS
01 20 00 PRICE AND PAYMENT PROCEDURES
01 30 00 ADMINISTRATIVE REQUIREMENTS
01 32 16.00 20 SMALL PROJECT CONSTRUCTION PROGRESS SCHEDULES
01 33 00 SUBMITTAL PROCEDURES
01 33 00A SUBMITTAL LOG (DIVISION 01)
01 33 16.00 10 DESIGN DATA (DESIGN AFTER AWARD)
01 33 29 SUSTAINABILITY REQUIREMENTS AND REPORTING
01 35 26 GOVERNMENTAL SAFETY REQUIREMENTS
01 42 00 SOURCES FOR REFERENCE PUBLICATIONS
01 45 00.00 10 QUALITY CONTROL
01 45 35 SPECIAL INSPECTIONS
01 50 00 TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS
01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS
01 74 19 CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL
01 78 00 CLOSEOUT SUBMITTALS
01 78 23 OPERATION AND MAINTENANCE DATA
01 91 00.15 10 TOTAL BUILDING COMMISSIONING
01 99 00 SUSTAINMENT MANAGEMENT SYSTEMS
01 99 00A SMS BUILDER DATA INVENTORY & ASSESSMENT SHEET
PART 3 – PROJECT PROGRAM
Part 3 includes a detailed description of the functional project requirements including program and project requirements. The Designer of Record is responsible for developing a complete set of stamped construction documents in compliance with applicable codes, criteria and regulations.
CHAPTER 1 & 2. PROJECT DESCRIPTION AND PROJECT OBJECTIVES
CHAPTER 3. SITE ANALYSIS
CHAPTER 4. SPACE TABULATION FORM
CHAPTER 5. ROOM REQUIREMENTS
CHAPTER 6. ENGINEERING SYSTEMS REQUIREMENTS
PART 4 – PERFORMANCE TECHNICAL SPECIFICATIONS
Part 4 includes technical specifications documenting the minimum performance standards. The Designer of Record is responsible for developing detailed project specifications that document the proposed design. Deviations from the requirements of Part 4 must be requested prior to inclusion in the proposed design.
The specifications included in Part 4 include minimum performance standards for many components of the work. The Performance Technical Specifications may not cover every item and inclusion or exclusion of items in this specification does not limit the Design-Builder’s responsibility to include the items required for a complete and usable facility in compliance with the applicable codes and standards. The Designer of Record will provide specifications for items not described herein based on code or UFC requirements and in alignment with industry standards.
A10 FOUNDATIONS
A20 BASEMENT CONSTRUCTION
B10 SUPERSTRUCTURE
B20 EXTERIOR ENCLOSURE
B30 ROOFING
C10 INTERIOR CONSTRUCTION
C20 STAIRS
C30 INTERIOR FINISHES
D10 CONVEYING
D20 PLUMBING
D30 HVAC
D40 FIRE PROTECTION
D50 ELECTRICAL
E10 EQUIPMENT
E20 FURNISHINGS
F10 SPECIAL CONSTRUCTION
F20 SELECT BLDG DEMOLITION
G10 SITE PREPARATIONS
G20 SITE IMPROVEMENTS
G30 SITE CIVIL/MECHANICAL UTILITIES
G40 SITE ELECTRICAL UTILITIES
Z10 GENERAL PERFORMANCE TECHNICAL SPECIFICATION
PART 5 – PRESCRIPTIVE SPECIFICATIONS
[-- Not used --]
PART 6 – ATTACHMENTS
Part 6 includes attachments that support the project scope definition including concept drawings including a phasing concept, surveys, studies, soils reports, environmental documentation, as-built drawings, existing conditions, forms, and other pertinent information..
CONCEPTUAL DRAWING PACKAGE
ROOM TYPICALS – FFE SURVEY
AFCEC/COSM TYPICAL MILLWORK DETAILS
PRELIMINARY PHASING STUDY
UFC 1-200-02 SCOPING AND GUIDANCE NARRATIVE
UFC 4-010-01 – ATFP CHECKLIST
FC 4-740-14F – 07 JULY 2015 DRAFT
TITLE 1A INVESTIGATORY REPORT
PRELIMINARY MINIMUM APPLICABLE UFGS TABLE OF CONTENTS
HANSCOM DESIGN GUIDANCE:
AE DESIGN GUIDE – 2021
ARCHITECTURAL COMPATIBILITY PLAN – 2013
CONTRACTOR ENV GUIDE – 2023
KTR HAZMAT SOP – 2020
LANDSCAPE STANDARDS – 2017
STORM WATER MANAGEMENT PLAN – 2021
(CUI) HAZWASTE MGMT PLAN – 2023
(CUI) INTEGRATED SOLID WASTE MGMT PLAN – 2022
(CUI) SPILL PREVENTION PLAN – 2022
Ronald W Wassmer Jr.
Highlight
PART 6 – ATTACHMENTS
Ronald W Wassmer Jr.
Highlight
CONCEPTUAL DRAWING PACKAGE
ROOM TYPICALS – FFE SURVEY
AFCEC/COSM TYPICAL MILLWORK DETAILS
PRELIMINARY PHASING STUDY
UFC 1-200-02 SCOPING AND GUIDANCE NARRATIVE
UFC 4-010-01 – ATFP CHECKLIST
FC 4-740-14F – 07 JULY 2015 DRAFT
Ronald W Wassmer Jr.
Highlight
PRELIMINARY MINIMUM APPLICABLE UFGS TABLE OF CONTENTS
Repair (Sustain) Child Development Center, B1994
MRXD 17-0051
OP 1086043
Hanscom Air Force Base, MA
Part Six
Conceptual Drawing Package
PROPERTY OF THE UNITED STATES AIR FORCE
B1994
CONCEPT DESIGN
SI
ZE
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
IS
SU
E
D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
D
EP
AR
TM
EN
T
O F
TH
E
AI
R
F O
R C
E
AI
R F
O R
C E
M
AT
ER
IA
L C
O M
M
AN
D th A
IR
B
AS
E
G R
O U
P/ C
E
BA
SE
C
IV
IL
E N
G
IN
EE
R
IN
G
D
IV
IS
IO
N
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EP
AI
R
(S U
ST
AI
N ) C
H
IL
D D
EV
EL
O
PM
EN
T
C
EN
TE
R
BU
IL
D
IN
G
SHEET IDENTIFICATION
H
AN
SC
O
M A
FB
, M
A
SM
M
A
SM
M
A
SM
M
A
SM
M
A
AN
SI
-D
1 2 7 8 9 103 4 5 6
A
B
C
D
E
F
G
66 AIR GROUPTH
BASE
SY
M
M
ES
M A
IN
I &
M cK
EE
A
SS
O
C
IA
TE
S
M as sa ch us et ts A ve C am br id ge
, M as sa ch us et ts
P:
7.
7.
ST
U
D Y
- N O
T
FO
C O
N
ST
R U
C
TI
O N
M
XR
D
7-
/0
9/
G-000
C O
VE
R
BUILDING 1604
AFLCMC/P2IA
BASE CONTRACTING
BUILDING 1825
BASE ENVIRONMENTAL OFFICE
72 DOW ST
BUILDING 1810
BASE CIVIL ENGINEERING(BCE)
120 GRENIER ST
BUILDING 1721
BASE SAFETY OFFICE
HARTWELL AVE
GATE
ROUTE 2A/VANDENBURG GATE
AND VISITOR CENTER
BUS
PLAYGROUND
PL
AY
G R
O U
N D
O
BS
C U
R E
PL
AY
G R
O U
N D
BA
SK
ET
BA
LL
C
O U
R T
PLAYGROUNDEQUIPMENT
BA
SK
ET
BA
LL
C
O U
R T
I-9
I-9
I-95
I-9
ATLANTIC OCEAN
BOSTON
BEDFORD
NASHUA
ATLANTIC OCEANMASSACHUSETTS
CONNECTICUT
VERMONT NEW HAMPSHIRE
RHODE
ISLAND
BOSTON
LEXINGTON
LYNN
SALEM
QUINCY
HINGHAM
WEYMOUTH
DEDHAM
BROOKLINE
FRAMINGHAM
BEDFORD
CONCORD
HANSCOM AFB
HANSCOM AFB, MASSACHUSETTS
MXRD 17-0051 - Repair (Sustain) Child Development Center Building 1994
SOLICITATION NO. :
CONTRACT NO. : MXRD 17-0051
ISSUE DATE : 01/09/2025
DEPARTMENT OF THE AIR FORCE
AIR FORCE MATERIEL COMMAND
HANSCOM AIR FORCE BASE
PREPARED FOR:
66th ABG/CEN CIVIL ENGINEERING DIRECTORATE
ENGINEERING AND DESIGN SECTION
HANSCOM AIR FORCE BASE
PREPARED BY:
SMMA
1000 MASSACHUSETTS AVE
CAMBRIDGE, MA 02138
VICINITY MAP N
E
AIR FORCE MAT R
I EL COMMAND TH
GROUP66 AIR BA SE
I-90
I-93
I-93
SYMMES MAINI & McKEE ASSOCIATES 1000 Massachusetts Ave Cambridge, Massachusetts 02138
P:617.547.5400
PROJECT SITE:
B1994
INDEX OF DRAWINGS
SHEET NUMBER SHEET NAME
GENERAL
G-000 COVER
ATFP
ATFP-01 ATFP CLEAR AREA
CIVIL
C-101 SITE PLAN
C-102 SITE PREPERATION PLAN
ARCHITECTURE
AD-101B FIRST FLOOR DEMO PLAN - PART B
AD-101A FIRST FLOOR DEMO PLAN - PART A
AD-101C FIRST FLOOR DEMO PLAN - PART C
AD-202 DEMO - ELEVATIONS - PART DAY PRESCHOOL
AD-203 DEMO - ELEVATIONS - ADMIN
AD-204 DEMO - ELEVATIONS - TODDLERS
AD-205 DEMO - ELEVATIONS - INFANTS
AD-201 DEMO - ELEVATIONS - PRESCHOOL
A-161 STUDY - EXTERIOR ANALYSIS
A-101A FIRST FLOOR CONST. PLAN - PART A
A-101C FIRST FLOOR CONST. PLAN - PART C
A-151A FIRST FLOOR RCP - PART A
A-151C FIRST FLOOR RCP - PART C
A-101B FIRST FLOOR CONST. PLAN - PART B
A-151B FIRST FLOOR RCP - PART B
A-201 ELEVATIONS - PRESCHOOL
A-202 ELEVATIONS - PART DAY PRESCHOOL
A-203 ELEVATIONS - ADMIN
A-204 ELEVATIONS - TODDLERS
A-205 ELEVATIONS - INFANTS
A-902 EXTERIOR PERSPECTIVES
A-701 ROOM FINISH SCHEDULE
FIRE PROTECTION
FAD101E FIRE ALARM DEMOLITION PLAN - EAST
FPD101E FIRE PROTECTION DEMOLITION PLAN - EAST
FAD101W FIRE ALARM DEMOLITION PLAN - WEST
FPD101W FIRE PROTECTION DEMOLITION PLAN - WEST
PLUMBING
PD101A 1ST FLOOR DEMOLITION PLAN - PART A
PD101B 1ST FLOOR DEMOLITION PLAN - PART B
PD101C 1ST FLOOR DEMOLITION PLAN - PART C
MECHANICAL
MD101A DEMOLITION PLAN - PART A
MD101B DEMOLITION PLAN - PART B
MD101C DEMOLITION PLAN - PART C
ELECTRICAL
EPD101E POWER DEMOLITION PLAN - EAST
ELD101E LIGHTING DEMOLITION PLAN - EAST
EPD101W POWER DEMOLITION PLAN - WEST
ELD101W LIGHTING DEMOLITION PLAN - WEST
EXISTING
BUILDING
EXISTING
BUILDING
EXISTING
BUILDING
(E ) F
R
EE
ZE
R
HYDRANT
150.0'
150.0'
133'
132'
136'
133'
133'
133'
133'
132'
2'
133'
133'
135'
133134
131'
133'
132'
130131
133'
REMOVE EXISTING BIT.
CONCRETE WALK, LOWER
GRADE AT BUILDING BY 6"
REMOVE EXISTING BIT.
CONCRETE WALK
REMOVE EXISTING BIT.
CONCRETE WALK
REMOVE EXISTING BIT.
CONCRETE WALK
REMOVE EXISTING BIT.
CONCRETE WALK
REMOVE EXISTING BIT.
CONCRETE WALK
REMOVE EXISTING BIT.
CONCRETE WALK (TYP.)
CUT EXISTING PVC
DOWNSPOUT AND INSTALL
CAST IRON BOOT W/PLUG
CLEAN OUT (TYPICAL AT 40
LOCATIONS)
REMOVE EXISTING BIT.
CONCRETE PAVEMENT
REMOVE EXISTING BIT.
CONCRETE PAVEMENT
RESTRIPE PARKING AREA
W/63'PARKING BAY (18.5' STALL,
26'ISLE).
REMOVE CURBING AND ISLAND,
REPAVE WITH BITUMINOUS PAVEMENT
NEW CURB, MATCH EXIST.
PLAYGROUND SURFACE TO REMAIN AND
PROTECTED THROUGHOUT
CONSTRUCTION. REMOVE SECTION AS
NECESSARY TO INSTALL CONCRETE
WALK. TERMINATE EDGE OF PLAT
SURFACE PER MANUFACTURES
RECOMMENDATION.
CONVERT EXISTING CATCH BASIN
TO DRAIN MANHOLE, ADD NEW
CATCH BASIN CONNECT TO DRAIN
MANHOLE WITH 12" HIGH DENSITY
POLYETHYLENE PIPE
CONVERT EXISTING CATCH BASIN
TO DRAIN MANHOLE, ADD NEW
CATCH BASIN CONNECT TO DRAIN
MANHOLE WITH 12" HIGH DENSITY
POLYETHYLENE PIPE
PLAYGROUND SURFACE TO REMAIN AND
PROTECTED THROUGHOUT
CONSTRUCTION. REMOVE SECTION AS
NECESSARY TO INSTALL CONCRETE
WALK. TERMINATE EDGE OF PLAT
SURFACE PER MANUFACTURES
RECOMMENDATION.
6' WIDE CONCRETE WALK
W/GRAVEL BASE AND NEW
STOOPS AT EXISTING DOORS2' WIDE GRASS
STRIP AT BUILDING
PLAYGROUND SURFACE TO REMAIN AND
PROTECTED THROUGHOUT
CONSTRUCTION. REMOVE SECTION AS
NECESSARY TO INSTALL CONCRETE
WALK. TERMINATE EDGE OF PLAT
SURFACE PER MANUFACTURES
RECOMMENDATION.
MATCHLINE
SEE INSET
REMOVE EXISTING EQUIPMENT
ENCLOSURE, FENCING AND
CONCRETE PAD. LOAM AND
SEED AT COMPLETION.
REMOVE EXISTING EQUIPMENT
ENCLOSURE, FENCING AND
CONCRETE PAD. LOAM AND
SEED AT COMPLETION.
REMOVE EXISTING EQUIPMENT
ENCLOSURE, FENCING AND
CONCRETE PAD. LOAM AND
SEED DISTURBED AREA UNLESS
OTHERWISE NOTED.
SAWCUT AND REMOVE EXISTING
BITUMINOUS PAVEMENT AND
ADJACENT CURB
REMOVE EXISTING EQUIPMENT
ENCLOSURE, FENCING AND
CONCRETE PAD
RELOCATE DOWNSPOUT
PROTECT TREE
PROTECT TREE
PROTECT TREE
RELOCATE STRUCTURE
SEE PARTIAL PLAN ON THIS
DRAWING FOR CONTINUATION
OF NORTH PARKING AREA
IMPROVEMENTS
BID OPTION 1
132'
131 131
BLACK OUT STRIPING & RESTRIPE
PARKING AREA FOR 60 DEGREE ANGLE
PARKING
MATCHLINE
INSET
N
PROPERTY OF THE UNITED STAES AIR FORCE
B1994
CONCEPT DESIGN
SI
ZE
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
IS
SU
E
D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
D
EP
AR
TM
EN
T
O F
TH
E
AI
R
F O
R C
E
AI
R F
O R
C E
M
AT
ER
IA
L C
O M
M
AN
D th A
IR
B
AS
E
G R
O U
P/ C
E
BA
SE
C
IV
IL
E N
G
IN
EE
R
IN
G
D
IV
IS
IO
N
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EP
AI
R
(S U
ST
AI
N ) C
H
IL
D D
EV
EL
O
PM
EN
T
C
EN
TE
R
BU
IL
D
IN
G
SHEET IDENTIFICATION
H
AN
SC
O
M A
FB
, M
A
SM
M
A
SM
M
A
SM
M
A
SM
M
A
AN
SI
-D
1 2 7 8 9 103 4 5 6
A
B
C
D
E
F
G E
AIR FORCE MAT R
IEL COMMAND
66 AIR GROUPTH
BASE
SY
M
M
ES
M A
IN
I &
M cK
EE
A
SS
O
C
IA
TE
S
M as sa ch us et ts A ve C am br id ge
, M as sa ch us et ts
P:
7.
7.
ST
U
D Y
- N O
T
FO
R C
O N
ST
R
U C
TI
O
N
LEGEND
PAVEMENT REMOVAL
C-101
SI
TE
P R
EP
AR
AT
IO
N
PL
AN
M
XR
D
7-
1. WORK WITHIN THE HANSCOM AIR FORCE BASE, AS A FEDERAL AGENCY
DOING WORK ON FEDERAL LAND, IS NOT SUBJECT TO LOCAL OR STATE
WETLAND BUFFER ZONE PROTECTIONS/REGULATION. THE GOVERNMENT IS
REQUIRED TO FOLLOW STATE AND LOCAL WETLAND REGULATIONS WHEN
WORK IS BEING DONE WITHIN THE WETLAND ITSELF OR WORK CAN AFFECT A
WETLAND, SUCH AS DISCHARGES. ALL FILINGS ARE TO BE COORDINATED
WITH THE CONTRACTING OFFICER FOR APPROVAL THROUGH THE
ENVIRONMENTAL OFFICE.
2. HAFB RECORDS INDICATE THAT THERE ARE MONITORING WELLS
LOCATED OUTSIDE THE SW END OF THE BUILDING. IF WELLS ARE
ENCOUNTERED DURING CONSTRUCTION ALERT THE CONTRACTING OFFICER
AND THE HANSCOM REMEDIAL PM (MATT GREENBERG). IF ENCOUNTERED,
THE WELLS ARE TO BE PROPERLY DECOMMISSIONED BY A MASSDEP
LICENSED DRILLER.
/0
9/
AutoCAD SHX Text
MW
AutoCAD SHX Text
MW
AutoCAD SHX Text
MW
AutoCAD SHX Text
MW
AutoCAD SHX Text U
AutoCAD SHX Text 1 inch = ft.
AutoCAD SHX Text
( IN FEET )
AutoCAD SHX Text
GRAPHIC SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
%%UPARTIAL PLAN NORTH PARKING AREA
AutoCAD SHX Text 1 inch = ft.
AutoCAD SHX Text
( IN FEET )
AutoCAD SHX Text
GRAPHIC SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING
BUILDING
EXISTING
BUILDING
EXISTING
BUILDING
(E ) F
R
EE
ZE
R
HYDRANT
V
AC
D O
AS
PI
TC
H
5' WIDE CONCRETE WALK
W/GRAVEL BASE AND NEW
STOOPS AT EXISTING DOORS
5' WIDE CONCRETE WALK
W/GRAVEL BASE AND NEW
STOOP AT EXISTING DOOR
5' WIDE CONCRETE WALK
W/GRAVEL BASE AND
EXPANDED WIDTH AT EXISTING
DOORS (TYP.)
CONCRETE PATIO W/GRAVEL
BASE AND NEW STOOPS AT
EXISTING DOORS
5' WIDE CONCRETE WALK
W/GRAVEL BASE AND
EXPANDED WIDTH AT EXISTING
DOORS (TYP.)
5' WIDE CONCRETE WALK
W/GRAVEL BASE
5' WIDE CONCRETE WALK
W/GRAVEL BASE AND
EXPANDED WIDTH AT DOORS
CONCRETE PATIO W/GRAVEL
BASE AND NEW STOOPS AT
EXISTING DOORS
CONCRETE PATIO W/GRAVEL
BASE AND NEW STOOPS AT
EXISTING DOORS
5' WIDE CONCRETE WALK
W/GRAVEL BASE
6' WIDE CONCRETE WALK
W/GRAVEL BASE
5' WIDE CONCRETE WALK
W/GRAVEL BASE
CUT EXISTING PVC
DOWNSPOUT AND INSTALL
CAST IRON BOOT W/PLUG
CLEAN OUT (TYPICAL AT 40
LOCATIONS)
PI
TC
H
PITCH
REMOVE EXISTING BIT.
CONCRETE PAVEMENT
PITCH
PITCH
PI
TC
H
PI
TC
H
PI
TC
H
PI
TC
H
PITCH
PITCH
PITCH
PI
TC
H
PI
TC
H
PITCH
PITCH
PI
TC
H
PI
TC
H
PI
TC
H
PITCH
PITCH
PITCH
PITCH
PITCH
PI
TC
H
PI
TC
H
PITCH
PI
TC
H
PITCH
PITCH
PITCH
PI
TC
H
PI
TC
H
PITCH
PITCH
PITCH
RESTRIPE PARKING AREA
W/63'PARKING BAY (18.5' STALL,
26'ISLE).
REMOVE CURBING AND ISLAND,
REPAVE WITH BITUMINOUS PAVEMENT
SIGN
R7-8
R7-8A
CONCRETE BUMPER (TYP.-5)
R7-8
NEW CURB, MATCH EXIST.
8' THICK CONCRETE EQUIPMENT
PAD W/GRAVEL BASE
(9.25' x 12.25')
PLAYGROUND SURFACE TO REMAIN AND
PROTECTED THROUGHOUT
CONSTRUCTION. REMOVE SECTION AS
NECESSARY TO INSTALL CONCRETE
WALK. TERMINATE EDGE OF PLAT
SURFACE PER MANUFACTURES
RECOMMENDATION.
CONVERT EXISTING CATCH BASIN
TO DRAIN MANHOLE, ADD NEW
CATCH BASIN CONNECT TO DRAIN
MANHOLE WITH 12" HIGH DENSITY
POLYETHYLENE PIPE
CONVERT EXISTING CATCH BASIN
TO DRAIN MANHOLE, ADD NEW
CATCH BASIN CONNECT TO DRAIN
MANHOLE WITH 12" HIGH DENSITY
POLYETHYLENE PIPE
REPLACE PATIO W/CONCRETE
PAVERS ON GRAVEL BASE AND
NEW CONCRETE STOOP AT
EXISTING DOORS
PI
TC
H
PI
TC
H
PLAYGROUND SURFACE TO REMAIN AND
PROTECTED THROUGHOUT
CONSTRUCTION. REMOVE SECTION AS
NECESSARY TO INSTALL CONCRETE
WALK. TERMINATE EDGE OF PLAT
SURFACE PER MANUFACTURES
RECOMMENDATION.
5' WIDE CONCRETE WALK
W/GRAVEL BASE WITH
EXISTING WALK AND PLAYGROUND
SURFACE TO REMAIN AND PROTECTED
THROUGHOUT CONSTRUCTION.
8' THICK CONCRETE EQUIPMENT
PAD W/GRAVEL BASE
(10' x 19.3')
CONCRETE FILLED STEEL
BOLLARD (TYP-7)
8' HIGH CHAIN LINK FENCE
W/2-8' WIDE DOUBLE LEAF
SWING GATES
8' HIGH MASONRY DUMPSTER
ENCLOSURE WITH TWO SLIDE GATES
8' THICK CONCRETE EQUIPMENT
PAD W/GRAVEL BASE
(10' x30')
5' WIDE CONCRETE WALK
W/GRAVEL BASE AND NEW
STOOPS AT EXISTING DOORS
8' THICK CONCRETE EQUIPMENT
PAD W/GRAVEL BASE
(9.25' x 12.25')
8' HIGH CHAIN LINK FENCE
W/2-8' WIDE DOUBLE LEAF
SWING GATES
8' THICK CONCRETE
EQUIPMENT PAD
W/GRAVEL BASE
(10' x 19.3')
8' HIGH CHAIN LINK
FENCE W/2-8' WIDE
DOUBLE LEAF
SWING GATES
RELOCATED STRUCTURE
SEE PARTIAL PLAN ON THIS
DRAWING FOR CONTINUATION
OF NORTH PARKING AREA
IMPROVEMENTS
BID OPTION
MATCHLINE
SEE INSET
EXISTING WALK TO REMAIN
EXPANDED CONCRETE WALK
AT DOORS (TYP.)
MATCH EXISTING WALK
MATCH EXISTING WALK
MATCH EXISTING WALK
MATCHLINE
INSET
V
5' WIDE CONCRETE WALK
RESTRIPE PARKING AREA FOR 60
DEGREE ANGLE PARKING
SIGN
R7-8
R7-8A
CONCRETE BUMPER (TYP.-5)
SIGN
R7-8
SIGN
R7-8
DETECTABLE WARNING STRIP (TYP.-3)
N
B1994
SI
ZE
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
IS
SU
E
D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
D
EP
AR
TM
EN
T
O F
TH
E
AI
R
F O
R C
E
AI
R F
O R
C E
M
AT
ER
IA
L C
O M
M
AN
D th A
IR
B
AS
E
G R
O U
P/ C
E
BA
SE
C
IV
IL
E N
G
IN
EE
R
IN
G
D
IV
IS
IO
N
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EP
AI
R
(S U
ST
AI
N ) C
H
IL
D D
EV
EL
O
PM
EN
T
C
EN
TE
R
BU
IL
D
IN
G
SHEET IDENTIFICATION
H
AN
SC
O
M A
FB
, M
A
SM
M
A
SM
M
A
SM
M
A
SM
M
A
AN
SI
-D
M
XR
D
7-
1 2 7 8 9 103 4 5 6
A
B
C
D
E
F
G E
AIR FORCE MAT R
IEL COMMAND
66 AIR GROUPTH
BASE
SY
M
M
ES
M A
IN
I &
M cK
EE
A
SS
O
C
IA
TE
S
M as sa ch us et ts A ve C am br id ge
, M as sa ch us et ts
P:
7.
7.
ST
U
D Y
- N O
T
FO
R C
O N
ST
R
U C
TI
O
N
1. DOOR STOOPS ARE TO MATCH EXISTING FLOOR ELEVATIONS. WALKS ARE NOT TO EXCEED 1.5% CROSS SLOPE OR 4% LONGITUDINAL SLOPE. PLAZAS ARE NOT TO EXCEED 1.5% SLOPE IN ANY DIRECTION.
2. GRADE AT GRASS STRIPS AROUND BUILDING IS TO BE 6" BELOW FINISH FLOOR.
3. WALKWAYS AND LANDSCAPE AREAS ARE TO PITCH AWAY FROM THE BUILDING.
4. PLAYGROUND SURFACE IS TO BE REMOVED AS NECESSARY TO INSTALL NEW CONCRETE
WALKWAYS. EDGE OF PLAYGROUND SURFACE IS TO BE CUT ALONG A STRAIGHT LINE AND TERMINATED IN
ACCORDANCE WITH MANUFACTURES RECOMMENDATIONS.
5. THE GOVERNMENT IS PERFORMING AN UPGRADE TO THE EXISTING PLAYGROUNDS AND ADJACENT PLAY SURFACES, SOME WORK MAY EXPAND INTO THE EXISTING SIDEWALKS. PERFORM SITE SURVEY TO CONFIRM EXISTING CONDITIONS AND INCORPORATE INTO SITE DESIGN WORK AS REQUIRED BY THIS DESIGN-BUILD. DOCUMENTS PRESENTED IN PART 6 ARE DIAGRAMMATIC IN NATURE, VERIFY EXISTING
CONDITIONS AS NEEDED TO COMPLETE THE DESIGN.
6. ALL DISTURBED AREAS ARE TO BE LOAMED AND SEEDED PER FC 4-740-14F, UNLESS OTHERWISE
NOTED.
NOTES:
HIGH DENSITY POLYETHYLENE
LEGEND
CONCRETE WALK, PAD & PATIO
CONCRETE PAVERS
CATCH BASIN
DRAIN MANHOLE CONVERSION
PIPE
C-102
SI
TE
P
LA
N
PROPERTY OF THE UNITED STAES AIR FORCE CONCEPT DESIGN
/0
9/
EDGE OF CLEAR AREA
'-0
'-0
33'-0"
33'-0"
'-0
33'-0"
'-0
'-0
33'-0"
33'-0"
PROPERTY OF THE UNITED STATES AIR FORCE
B1994
CONCEPT DESIGN
SI
ZE
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
IS
SU
E
D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
D
EP
AR
TM
EN
T
O F
TH
E
AI
R
F O
R C
E
AI
R F
O R
C E
M
AT
ER
IA
L C
O M
M
AN
D th A
IR
B
AS
E
G R
O U
P/ C
E
BA
SE
C
IV
IL
E N
G
IN
EE
R
IN
G
D
IV
IS
IO
N
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EP
AI
R
(S U
ST
AI
N ) C
H
IL
D D
EV
EL
O
PM
EN
T
C
EN
D
IN
G
SHEET IDENTIFICATION
H
AN
SC
O
M A
FB
, M
A
SM
M
A
SM
M
A
SM
M
A
SM
M
A
AN
SI
-D
1 2 7 8 9 103 4 5 6
A
B
C
D
E
F
G
66 AIR GROUPTH
BASE
SY
M
M
ES
M A
IN
I &
M cK
EE
A
SS
O
C
IA
TE
S
M as sa ch us et ts A ve C am br id ge
, M as sa ch us
P:
7.
7.
D Y
- N O
T
N
ST
R U
C
TI
O N
M
XR
D
7-
/0
9/
ATFP-01
AT
FP
C
LE
AR
A
R
EA
SCALE: 1" = 30'-0"
ATFP STUDY - SITE PLANA1
G G
E E
D.3 D.3 D.2 D.2
D.1 D.1
C C
B B
A A
E.2 E.2
PRE-SCHOOL
114PRE-SCHOOL
PRE-SCHOOL
PRE-SCHOOL
PRE-SCHOOL
PRE-SCHOOL
PRE-TODDLER
PART DAY
PRE-SCHOOL
PART DAY
PRE-SCHOOL
STORAGE
RESTROOM
RESTROOM
STORAGE
RESTROOM
STORAGE
STORAGE
RESTROOM
STORAGE
RESTROOM
RESTROOM
STORAGE
STORAGE
STORAGE
RESTROOM
RESTROOM
STORAGE
RESTROOM
RESTROOM
STORAGE
STORAGE
STORAGE
CORRIDOR
CORRIDOR
F201002.C
F201002.B
F201006.A
F201006.A
F201004.A
F201004.C
F201004.D
F201004.B
STAFF
WORKROOM
F201002.I
F201002.I
F201002.I
1. THE CONTRACTOR SCOPE INCLUDES THE FOLLOWING:
a. REMOVAL OF ALL ITEMS OF ANY NATURE SHOWN WITHIN SCOPE OF WORK.
b. BEFORE COMMENCING THE WORK, VERIFICATION AT THE SITE OF EXISTING CONSTRUCTION TO BE
PRESERVED AND REPORTING TO THE ARCHITECT OF ANY DISCREPANCIES OR QUESTIONABLE ITEMS.
2. COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO
SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION.
3. PROVIDE AND MAINTAIN BARRICADES, LIGHTING AND GUARDRAILS AS REQUIRED BY APPLICABLE CODES
AND REGULATIONS TO PROTECT OCCUPANTS OF BUILDING AND WORKERS.
4. ERECT AND MAINTAIN DUST-PROOF PARTITIONS AS REQUIRED TO PREVENT SPREAD OF DUST, FUMES AND SMOKE, ETC. TO OTHER PARTS OF THE BUILDING. ON COMPLETION, REMOVE PARTITIONS AND REPAIR
DAMAGED SURFACES TO MATCH ADJACENT SURFACES.
5. PRIOR TO DEMOLITION, MEET WITH THE CONTRACTING OFFICER TO IDENTIFY ITEMS WHICH ARE TO BE SALVAGED. ALL OTHER DEMOLISHED MATERIALS ARE TO BE REMOVED FROM THE SITE AND DISPOSE OF THEM
LEGALLY BY THE CONTRACTOR.
6. EXISTING SERVICES AND SYSTEMS: MAINTAIN SERVICES AND SYSTEMS INDICATED TO REMAIN AND PROTECT THEM AGAINST DAMAGE DURING SELECTIVE DEMOLITION OPERATIONS. WHERE MECHANICAL OR ELECTRICAL SYSTEMS ARE INDICATED TO BE SELECTIVELY DEMOLISHED, LOCATE, IDENTIFY, DISCONNECT, AND
SEAL OR CAP OFF INDICATED UTILITY SERVICES IN CONCEALED LOCATION.
7. REMOVE AND SALVAGE DEBRIS FROM THE SITE DAILY AS IT ACCUMULATES. REMOVE RENOVATION
MATERIALS FROM THE SITE, LEAVING A CLEAN, VACUUMED SPACE.
8. PROTECT EXISTING CONSTRUCTION TO REMAIN. REPAIR ANY DAMAGE TO EXISTING CONSTRUCTION IN A MANNER ACCEPTABLE TO THE OWNER OR REPLACE SUCH DAMAGE WITH NEW ACCEPTABLE TO GOVERNMENT
AND AT NO COST TO GOVERNMENT.
9. REFER TO ENGINEERED PLANS FOR FURTHER DEMOLITION OF MECHANICAL, ELECTRICAL, FIRE
PROTECTION AND PLUMBING ITEMS.
10. SALVAGE BUILDING STANDARD LIGHT FIXTURES AT CEILING DEMOLISHED AREAS FOR RE-USE.
COORDINATE WITH CONTRACTING OFFICER WHICH LIGHT FIXTURES ARE TO BE SALVAGED FOR STORAGE.
11. SALVAGE DEVICES THAT ARE BUILDING STANDARD THAT MEET CURRENT CODE REQUIREMENTS FOR RE-
USE (EXIT SIGNS, HORN STROBES, EMERGENCY LIGHTS).
12. CUT AND CAP EXISTING DISCONTINUED MEP/FP CONDUITS AND OTHER MISC. ITEMS THAT PENETRATE THE
SLAB. FILL VOIDS IN SLAB WITH CONCRETE AND MAINTAIN EXISTING FIRE RATING.
13. CUT AND CAP EXISTING DISCONTINUED MEP/FP CONDUITS, DUCTWORK AND MISC. ITEMS THAT PENETRATE RATED PARTITIONS. FILL VOIDS WITH FIRE STOP MATERIAL AND MAINTAIN EXISTING FIRE RATING.
14. REMOVE UNUSED WIRING BACK TO MAIN PANEL OR NEAREST JUNCTION BOX.
15. THE CONTRACTOR SHALL REMOVE ALL ABANDONED PIPING, CONDUIT, DEVICES & WIRING BACK TO
SOURCE. REMOVE UNUSED WIRING BACK TO MAIN PANEL.
16. UTILIZE BRACING AND SHORING WHERE NECESSARY TO PREVENT COLLAPSE OF STRUCTURE OR PARTS THEREOF. GENERAL CONTRACTOR IS RESPONSIBLE FOR DESIGN AND CONSTRUCTION OF ALL BRACING AND
SHORING.
17. REMOVE AND DISPOSE OF ALL EXISTING SWITCHES, TEL/DATA/VOICE WIRING, AND J-BOXES IN DEMOLITION AREA UNLESS SPECIFIED TO BE REUSED. PATCH AND REPAIR FLOOR AND WALLS TO AN "AS NEW" CONDITION.
18. REMOVE DESIGNATED PARTITIONS, COMPONENTS, BUILDING EQUIPMENT AND FIXTURES AS REQUIRED
FOR NEW WORK.
19. REFER TO CONSTRUCTION PLAN AND DOOR SCHEDULE FOR NUMBER OF DOORS/HARDWARE NEEDED TO
BE SALVAGED, STORED AND RELOCATED.
20. ALL AUDIO VISUAL EQUIPMENT, PROJECTION SCREENS AND PROJECTORS THAT ARE SCHEDULED TO REMAIN ARE TO BE PROTECTED FROM DUST AND DEBRIS DURING DEMOLITION AND CONSTRUCTION.
21. AT FURNITURE TO BE DEMOLISHED, GENERAL CONTRACTOR SHALL COORDINATE WITH FURNITURE
VENDOR TO PROVIDE ANY NECESSARY ELECTRICAL DISCONNECTS AND MAKE SAFE.
DEMOLITION PLAN GENERAL NOTES
DEMOLITION SYMBOLS LEGEND
EXISTING DOOR TO REMAIN, TYP U.O.N.
REMOVE EXISTING DOOR & FRAME
COMPLETELY.
REMOVE PORTION OF EXISTING
WALL. SEE FLOORPLAN FOR
LOCATION AND DIMENSION. TYP
U.O.N.
EXISTING WALL OR PARTITION TO
REMAIN, TYP U.O.N.
REMOVE ALL CONSTRUCTION
SHOWN DASHED COMPLETE,
U.O.N.
LOCATION OF FLOORING
REMOVAL
04 8 16268
SCALE: 1/8"=1'-0"
PROPERTY OF THE UNITED STATES AIR FORCE
B1994
CONCEPT DESIGN
SI
ZE
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
IS
SU
E
D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
D
EP
AR
TM
EN
T
O F
TH
E
AI
R
F O
R C
E
AI
R F
O R
C E
M
AT
ER
IA
L C
O M
M
AN
D th A
IR
B
AS
E
G R
O U
P/ C
E
BA
SE
C
IV
IL
E N
G
IN
EE
R
IN
G
D
IV
IS
IO
N
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EP
AI
R
(S U
ST
AI
N ) C
H
IL
D D
EV
EL
O
PM
EN
T
C
EN
D
IN
G
SHEET IDENTIFICATION
H
AN
SC
O
M A
FB
, M
A
SM
M
A
SM
M
A
SM
M
A
SM
M
A
AN
SI
-D
1 2 7 8 9 103 4 5 6
A
B
C
D
E
F
G
66 AIR GROUPTH
BASE
SY
M
M
ES
M A
IN
I &
M cK
EE
A
SS
O
C
IA
TE
S
M as sa ch us et ts A ve C am br id ge
, M as sa ch us
P:
7.
7.
PLAN NORTH
U
D Y
- N O
T
N
ST
R U
C
TI
O N
A
B
KEYPLAN
C
M
XR
D
7-
/0
9/
AD-101A
FI
R
ST
F
LO
O
R D
EM
O
P
LA
N
PA
R
T A
SCALE: 1/8" = 1'-0"
1ST FLOOR DEMOLITION PLAN - PART AA1
KEYNOTE LEGEND
REFER TO DBRFP PART 3 FOR ADDITIONAL SCOPING INFORMATION
KEY VALUE KEYNOTE TEXT
F201002.B REMOVE EXTERIOR WINDOWS AND LOUVERS. REMOVE PRECAST
WINDOW SILLS. REMOVE EXISTING SUBSTRATE NOT SUITABLE FOR
WINDOW REPLACEMENT.
F201002.C REMOVE EXTERIOR HOLLOW METAL MAN DOORS AND FRAMES,
REMOVE AND REPLACE THRESHOLDS.
F201002.I REMOVE MECHANICAL UNIT SCREEN, PAD AND DUCTWORK
ENCLOSURES
F201004.A REMOVE INTERIOR WINDOWS
F201004.B REMOVE INTERIOR DOORS AND FRAMES
F201004.C REMOVE MILLWORK, TYP. THROUGHOUT
F201004.D REMOVE DIAPER CHANGING STATION, CAP PLUMBING AS REQ'D FOR
REPLACEMENT, TYP. THROUGHOUT
F201006.A REMOVE CHILD HEIGHT WALL HUNG VANITY
E E
D.3
F F
E.2 E.2
D D
1914.9
14.9
/A1 AD-101A
PRE-SCHOOL
PRE-TODDLER
PART DAY
PRE-SCHOOL
STORAGE
STORAGE
CORRIDOR
F201002.C
F201002.B
4.1.1.3 F201002.D
F201002.D F201002.D
STAFF
WORKROOM
CHILDCARE
COORD.
WING SUP.
ASST. DIR.
OFFICE
DIRECTOR
OFFICE
BREAK
ROOM
149 HEALTH
ROOM
WING SUP
AND ADMIN
RECEPTION/
LOBBY
ELEC. ROOM
MECH. ROOM
KITCHEN
KITCHEN
STORAGE
106C
KITCHEN
OFFICE
106B
SERVICE
CORR.
106A
COMM.
ROOM
COMPUTER
ROOM
VESTIBULE
WOMEN'S
ROOM
JAN.
STORAGE
STAFF
RESTROOM
MOTHER'S
ROOM
HEALTH
RESTROOM
152.1
B2010.D
B2010.E
C1010.A
REFER TO FFE TYPICALS
APPENDIX FOR PICTURES AND
QUANTIIES OF KITCHEN
EQUIPMENT
1. THE CONTRACTOR SCOPE INCLUDES THE FOLLOWING:
a. REMOVAL OF ALL ITEMS OF ANY NATURE SHOWN WITHIN SCOPE OF WORK.
b. BEFORE COMMENCING THE WORK, VERIFICATION AT THE SITE OF EXISTING CONSTRUCTION TO BE
PRESERVED AND REPORTING TO THE ARCHITECT OF ANY DISCREPANCIES OR QUESTIONABLE ITEMS.
2. COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO
SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION.
3. PROVIDE AND MAINTAIN BARRICADES, LIGHTING AND GUARDRAILS AS REQUIRED BY APPLICABLE CODES
AND REGULATIONS TO PROTECT OCCUPANTS OF BUILDING AND WORKERS.
4. ERECT AND MAINTAIN DUST-PROOF PARTITIONS AS REQUIRED TO PREVENT SPREAD OF DUST, FUMES AND SMOKE, ETC. TO OTHER PARTS OF THE BUILDING. ON COMPLETION, REMOVE PARTITIONS AND REPAIR
DAMAGED SURFACES TO MATCH ADJACENT SURFACES.
5. PRIOR TO DEMOLITION, MEET WITH THE CONTRACTING OFFICER TO IDENTIFY ITEMS WHICH ARE TO BE SALVAGED. ALL OTHER DEMOLISHED MATERIALS ARE TO BE REMOVED FROM THE SITE AND DISPOSE OF THEM
LEGALLY BY THE CONTRACTOR.
6. EXISTING SERVICES AND SYSTEMS: MAINTAIN SERVICES AND SYSTEMS INDICATED TO REMAIN AND PROTECT THEM AGAINST DAMAGE DURING SELECTIVE DEMOLITION OPERATIONS. WHERE MECHANICAL OR ELECTRICAL SYSTEMS ARE INDICATED TO BE SELECTIVELY DEMOLISHED, LOCATE, IDENTIFY, DISCONNECT, AND
SEAL OR CAP OFF INDICATED UTILITY SERVICES IN CONCEALED LOCATION.
7. REMOVE AND SALVAGE DEBRIS FROM THE SITE DAILY AS IT ACCUMULATES. REMOVE RENOVATION
MATERIALS FROM THE SITE, LEAVING A CLEAN, VACUUMED SPACE.
8. PROTECT EXISTING CONSTRUCTION TO REMAIN. REPAIR ANY DAMAGE TO EXISTING CONSTRUCTION IN A MANNER ACCEPTABLE TO THE OWNER OR REPLACE SUCH DAMAGE WITH NEW ACCEPTABLE TO GOVERNMENT
AND AT NO COST TO GOVERNMENT.
9. REFER TO ENGINEERED PLANS FOR FURTHER DEMOLITION OF MECHANICAL, ELECTRICAL, FIRE
PROTECTION AND PLUMBING ITEMS.
10. SALVAGE BUILDING STANDARD LIGHT FIXTURES AT CEILING DEMOLISHED AREAS FOR RE-USE.
COORDINATE WITH CONTRACTING OFFICER WHICH LIGHT FIXTURES ARE TO BE SALVAGED FOR STORAGE.
11. SALVAGE DEVICES THAT ARE BUILDING STANDARD THAT MEET CURRENT CODE REQUIREMENTS FOR RE-
USE (EXIT SIGNS, HORN STROBES, EMERGENCY LIGHTS).
12. CUT AND CAP EXISTING DISCONTINUED MEP/FP CONDUITS AND OTHER MISC. ITEMS THAT PENETRATE THE
SLAB. FILL VOIDS IN SLAB WITH CONCRETE AND MAINTAIN EXISTING FIRE RATING.
13. CUT AND CAP EXISTING DISCONTINUED MEP/FP CONDUITS, DUCTWORK AND MISC. ITEMS THAT PENETRATE RATED PARTITIONS. FILL VOIDS WITH FIRE STOP MATERIAL AND MAINTAIN EXISTING FIRE RATING.
14. REMOVE UNUSED WIRING BACK TO MAIN PANEL OR NEAREST JUNCTION BOX.
15. THE CONTRACTOR SHALL REMOVE ALL ABANDONED PIPING, CONDUIT, DEVICES & WIRING BACK TO
SOURCE. REMOVE UNUSED WIRING BACK TO MAIN PANEL.
16. UTILIZE BRACING AND SHORING WHERE NECESSARY TO PREVENT COLLAPSE OF STRUCTURE OR PARTS THEREOF. GENERAL CONTRACTOR IS RESPONSIBLE FOR DESIGN AND CONSTRUCTION OF ALL BRACING AND
SHORING.
17. REMOVE AND DISPOSE OF ALL EXISTING SWITCHES, TEL/DATA/VOICE WIRING, AND J-BOXES IN DEMOLITION AREA UNLESS SPECIFIED TO BE REUSED. PATCH AND REPAIR FLOOR AND WALLS TO AN "AS NEW" CONDITION.
18. REMOVE DESIGNATED PARTITIONS, COMPONENTS, BUILDING EQUIPMENT AND FIXTURES AS REQUIRED
FOR NEW WORK.
19. REFER TO CONSTRUCTION PLAN AND DOOR SCHEDULE FOR NUMBER OF DOORS/HARDWARE NEEDED TO
BE SALVAGED, STORED AND RELOCATED.
20. ALL AUDIO VISUAL EQUIPMENT, PROJECTION SCREENS AND PROJECTORS THAT ARE SCHEDULED TO REMAIN ARE TO BE PROTECTED FROM DUST AND DEBRIS DURING DEMOLITION AND CONSTRUCTION.
21. AT FURNITURE TO BE DEMOLISHED, GENERAL CONTRACTOR SHALL COORDINATE WITH FURNITURE
VENDOR TO PROVIDE ANY NECESSARY ELECTRICAL DISCONNECTS AND MAKE SAFE.
DEMOLITION PLAN GENERAL NOTES
DEMOLITION SYMBOLS LEGEND
EXISTING DOOR TO REMAIN, TYP U.O.N.
REMOVE EXISTING DOOR & FRAME
COMPLETELY.
REMOVE PORTION OF EXISTING
WALL. SEE FLOORPLAN FOR
LOCATION AND DIMENSION. TYP
U.O.N.
EXISTING WALL OR PARTITION TO
REMAIN, TYP U.O.N.
REMOVE ALL CONSTRUCTION
SHOWN DASHED COMPLETE,
U.O.N.
LOCATION OF FLOORING
REMOVAL
04 8 16268
SCALE: 1/8"=1'-0"
PROPERTY OF THE UNITED STATES AIR FORCE
B1994
CONCEPT DESIGN
SI
ZE
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
IS
SU
E
D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
D
EP
AR
TM
EN
T
O F
TH
E
AI
R
F O
R C
E
AI
R F
O R
C E
M
AT
ER
IA
L C
O M
M
AN
D th A
IR
B
AS
E
G R
O U
P/ C
E
BA
SE
C
IV
IL
E N
G
IN
EE
R
IN
G
D
IV
IS
IO
N
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EP
AI
R
(S U
ST
AI
N ) C
H
IL
D D
EV
EL
O
PM
EN
T
C
EN
D
IN
G
SHEET IDENTIFICATION
H
AN
SC
O
M A
FB
, M
A
SM
M
A
SM
M
A
SM
M
A
SM
M
A
AN
SI
-D
1 2 7 8 9 103 4 5 6
A
B
C
D
E
F
G
66 AIR GROUPTH
BASE
SY
M
M
ES
M A
IN
I &
M cK
EE
A
SS
O
C
IA
TE
S
M as sa ch us et ts A ve C am br id ge
, M as sa ch us
P:
7.
7.
U
D Y
- N O
T
N
ST
R U
C
TI
O N
A
B
KEYPLAN
C
M
XR
D
7-
/0
9/
AD-101B
FI
R
ST
F
LO
O
R D
EM
O
P
LA
N
PA
R
T B
SCALE: 1/8" = 1'-0"
1ST FLOOR DEMOLITION PLAN - PART BA1
KEYNOTE LEGEND
REFER TO DBRFP PART 3 FOR ADDITIONAL SCOPING INFORMATION
KEY VALUE KEYNOTE TEXT
4.1.1.3 PROVIDE A DEDICATED MOTHERS ROOM IN THE BUILDING,
CONCEPTUAL LAYOUT AND LOCATION IS PROVIDED IN THE
CONCEPT DESIGN PACKAGE.
B2010.D EXISTING MASONRY SCREEN WALL NOT STRUCTURALLY SOUND,
RECONSTRUCT AS NEEDED
B2010.E RECONSTRUCT WALL BASE WITH COLOR MATCHED BRICK AND
GROUT TO PROVIDE PROPER THROUGH WALL FLASHING AND
WEEPS. PROVIDE SHORING AND ANY REPAIRS TO ADJACENT
CONSTRUCTION. BRICK SIZE, COLOR, AND COURSING TO MATCH
EXISTING.
C1010.A REPLACE DAMAGED GYPSUM BOARD
F201002.B REMOVE EXTERIOR WINDOWS AND LOUVERS. REMOVE PRECAST
WINDOW SILLS. REMOVE EXISTING SUBSTRATE NOT SUITABLE FOR
WINDOW REPLACEMENT.
F201002.C REMOVE EXTERIOR HOLLOW METAL MAN DOORS AND FRAMES,
REMOVE AND REPLACE THRESHOLDS.
F201002.D REMOVE STOREFRONT ASSEMBLIES INCLUDING DOORS, GLAZING,
FRAMING AND METAL PANELS, PREP SLAB AND HEAD CONDITION
FOR NEW ASSEMBLIES.
W W
W
1. THE CONTRACTOR SCOPE INCLUDES THE FOLLOWING:
a. REMOVAL OF ALL ITEMS OF ANY NATURE SHOWN WITHIN SCOPE OF WORK.
b. BEFORE COMMENCING THE WORK, VERIFICATION AT THE SITE OF EXISTING CONSTRUCTION TO BE
PRESERVED AND REPORTING TO THE ARCHITECT OF ANY DISCREPANCIES OR QUESTIONABLE ITEMS.
2. COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO
SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION.
3. PROVIDE AND MAINTAIN BARRICADES, LIGHTING AND GUARDRAILS AS REQUIRED BY APPLICABLE CODES
AND REGULATIONS TO PROTECT OCCUPANTS OF BUILDING AND WORKERS.
4. ERECT AND MAINTAIN DUST-PROOF PARTITIONS AS REQUIRED TO PREVENT SPREAD OF DUST, FUMES AND SMOKE, ETC. TO OTHER PARTS OF THE BUILDING. ON COMPLETION, REMOVE PARTITIONS AND REPAIR
DAMAGED SURFACES TO MATCH ADJACENT SURFACES.
5. PRIOR TO DEMOLITION, MEET WITH THE CONTRACTING OFFICER TO IDENTIFY ITEMS WHICH ARE TO BE SALVAGED. ALL OTHER DEMOLISHED MATERIALS ARE TO BE REMOVED FROM THE SITE AND DISPOSE OF THEM
LEGALLY BY THE CONTRACTOR.
6. EXISTING SERVICES AND SYSTEMS: MAINTAIN SERVICES AND SYSTEMS INDICATED TO REMAIN AND PROTECT THEM AGAINST DAMAGE DURING SELECTIVE DEMOLITION OPERATIONS. WHERE MECHANICAL OR ELECTRICAL SYSTEMS ARE INDICATED TO BE SELECTIVELY DEMOLISHED, LOCATE, IDENTIFY, DISCONNECT, AND
SEAL OR CAP OFF INDICATED UTILITY SERVICES IN CONCEALED LOCATION.
7. REMOVE AND SALVAGE DEBRIS FROM THE SITE DAILY AS IT ACCUMULATES. REMOVE RENOVATION
MATERIALS FROM THE SITE, LEAVING A CLEAN, VACUUMED SPACE.
8. PROTECT EXISTING CONSTRUCTION TO REMAIN. REPAIR ANY DAMAGE TO EXISTING CONSTRUCTION IN A MANNER ACCEPTABLE TO THE OWNER OR REPLACE SUCH DAMAGE WITH NEW ACCEPTABLE TO GOVERNMENT
AND AT NO COST TO GOVERNMENT.
9. REFER TO ENGINEERED PLANS FOR FURTHER DEMOLITION OF MECHANICAL, ELECTRICAL, FIRE
PROTECTION AND PLUMBING ITEMS.
10. SALVAGE BUILDING STANDARD LIGHT FIXTURES AT CEILING DEMOLISHED AREAS FOR RE-USE.
COORDINATE WITH CONTRACTING OFFICER WHICH LIGHT FIXTURES ARE TO BE SALVAGED FOR STORAGE.
11. SALVAGE DEVICES THAT ARE BUILDING STANDARD THAT MEET CURRENT CODE REQUIREMENTS FOR RE-
USE (EXIT SIGNS, HORN STROBES, EMERGENCY LIGHTS).
12. CUT AND CAP EXISTING DISCONTINUED MEP/FP CONDUITS AND OTHER MISC. ITEMS THAT PENETRATE THE
SLAB. FILL VOIDS IN SLAB WITH CONCRETE AND MAINTAIN EXISTING FIRE RATING.
13. CUT AND CAP EXISTING DISCONTINUED MEP/FP CONDUITS, DUCTWORK AND MISC. ITEMS THAT PENETRATE RATED PARTITIONS. FILL VOIDS WITH FIRE STOP MATERIAL AND MAINTAIN EXISTING FIRE RATING.
14. REMOVE UNUSED WIRING BACK TO MAIN PANEL OR NEAREST JUNCTION BOX.
15. THE CONTRACTOR SHALL REMOVE ALL ABANDONED PIPING, CONDUIT, DEVICES & WIRING BACK TO
SOURCE. REMOVE UNUSED WIRING BACK TO MAIN PANEL.
16. UTILIZE BRACING AND SHORING WHERE NECESSARY TO PREVENT COLLAPSE OF STRUCTURE OR PARTS THEREOF. GENERAL CONTRACTOR IS RESPONSIBLE FOR DESIGN AND CONSTRUCTION OF ALL BRACING AND
SHORING.
17. REMOVE AND DISPOSE OF ALL EXISTING SWITCHES, TEL/DATA/VOICE WIRING, AND J-BOXES IN DEMOLITION AREA UNLESS SPECIFIED TO BE REUSED. PATCH AND REPAIR FLOOR AND WALLS TO AN "AS NEW" CONDITION.
18. REMOVE DESIGNATED PARTITIONS, COMPONENTS, BUILDING EQUIPMENT AND FIXTURES AS REQUIRED
FOR NEW WORK.
19. REFER TO CONSTRUCTION PLAN AND DOOR SCHEDULE FOR NUMBER OF DOORS/HARDWARE NEEDED TO
BE SALVAGED, STORED AND RELOCATED.
20. ALL AUDIO VISUAL EQUIPMENT, PROJECTION SCREENS AND PROJECTORS THAT ARE SCHEDULED TO REMAIN ARE TO BE PROTECTED FROM DUST AND DEBRIS DURING DEMOLITION AND CONSTRUCTION.
21. AT FURNITURE TO BE DEMOLISHED, GENERAL CONTRACTOR SHALL COORDINATE WITH FURNITURE
VENDOR TO PROVIDE ANY NECESSARY ELECTRICAL DISCONNECTS AND MAKE SAFE.
DEMOLITION PLAN GENERAL NOTES
DEMOLITION SYMBOLS LEGEND
EXISTING DOOR TO REMAIN, TYP U.O.N.
REMOVE EXISTING DOOR & FRAME
COMPLETELY.
REMOVE PORTION OF EXISTING
WALL. SEE FLOORPLAN FOR
LOCATION AND DIMENSION. TYP
U.O.N.
EXISTING WALL OR PARTITION TO
REMAIN, TYP U.O.N.
REMOVE ALL CONSTRUCTION
SHOWN DASHED COMPLETE,
U.O.N.
LOCATION OF FLOORING
REMOVAL
U U
S S
Q Q
N N
L L
J.1 J.1
H H
G.1 G.1
M M
P P
K K
R R
/A1 AD-101B
/A1 AD-101A
F201004.D
F201004.C
F201004.C
CORRIDOR
194 INFANTS 10
190 INFANTS 11
INFANTS 12
INFANTS 13
PRE-TODDLERS
PRE-TODDLERS
PRE-TODDLERS
TODDLERS
TODDLERS
TODDLERS
STORAGE
STORAGE
STORAGE
STORAGE
STORAGE
STORAGE
STORAGE
STORAGE
STORAGE
CORRIDOR
CORRIDOR
TRAINING &
CIRC.
TRAINING &
CIRC.
LAUNDRY
STORAGE
STORAGE
STORAGE
STORAGE
STORAGE
STORAGE
STORAGE
STORAGE
STORAGE
RESTROOM
STORAGE
STORAGE
STORAGE
F201002.I
F201002.I
4.1.1.8
04 8 16268
SCALE: 1/8"=1'-0"
PROPERTY OF THE UNITED STATES AIR FORCE
B1994
CONCEPT DESIGN
SI
ZE
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
IS
SU
E
D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
D
EP
AR
TM
EN
T
O F
TH
E
AI
R
F O
R C
E
AI
R F
O R
C E
M
AT
ER
IA
L C
O M
M
AN
D th A
IR
B
AS
E
G R
O U
P/ C
E
BA
SE
C
IV
IL
E N
G
IN
EE
R
IN
G
D
IV
IS
IO
N
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EP
AI
R
(S U
ST
AI
N ) C
H
IL
D D
EV
EL
O
PM
EN
T
C
EN
D
IN
G
SHEET IDENTIFICATION
H
AN
SC
O
M A
FB
, M
A
SM
M
A
SM
M
A
SM
M
A
SM
M
A
AN
SI
-D
1 2 7 8 9 103 4 5 6
A
B
C
D
E
F
G
66 AIR GROUPTH
BASE
SY
M
M
ES
M A
IN
I &
M cK
EE
A
SS
O
C
IA
TE
S
M as sa ch us et ts A ve C am br id ge
, M as sa ch us
P:
7.
7.
U
D Y
- N O
T
N
ST
R U
C
TI
O N
A
B
KEYPLAN
C
M
XR
D
7-
/0
9/
AD-101C
FI
R
ST
F
LO
O
R D
EM
O
P
LA
N
PA
R
T C
SCALE: 1/8" = 1'-0"
1ST FLOOR DEMOLITION PLAN - PART CA1
KEYNOTE LEGEND
REFER TO DBRFP PART 3 FOR ADDITIONAL SCOPING
INFORMATION
KEY VALUE KEYNOTE TEXT
4.1.1.8 PROVIDE NEW EGRESS CORRIDOR TO THE
NORTH OF COLUMN LINE "M" REMOVING
SPACE FROM INFANT ROOM 11. CORRIDOR TO
BE NO LESS THAN 4'6" WIDE. REFER TO PART
3 FOR ADDITIONAL INFORMATION.
F201002.I REMOVE MECHANICAL UNIT SCREEN, PAD
AND DUCTWORK ENCLOSURES
F201004.C REMOVE MILLWORK, TYP. THROUGHOUT
F201004.D REMOVE DIAPER CHANGING STATION, CAP
PLUMBING AS REQ'D FOR REPLACEMENT,
TYP. THROUGHOUT
1ST FLOOR
134'-0"
12358913 4671011
TOS - EAVE
143'-3 3/4"
TOS - PRESCHOOL
160'-2 3/4"
F201002.B
F201002.C
F201002.A
1ST FLOOR
134'-0"
D.3
D.2D.1CBA
TOS - EAVE
143'-3 3/4"
TOS - PRESCHOOL
160'-2 3/4"
F201002.C
F201002.B
F201002.A
F201003.A
F201002.I
F201003.A
F201002.E
1ST FLOOR
134'-0"
D.3D.2 D.1 C B A
TOS - EAVE
143'-3 3/4"
TOS - PRESCHOOL
160'-2 3/4"
F201002.B
F201002.C
F201002.E F201003.A
F201003.A
1ST FLOOR
134'-0"
1 2 3 5 8 9 137
TOS - EAVE
143'-3 3/4"
TOS - PRESCHOOL
160'-2 3/4"
F201002.C F201002.B
1ST FLOOR
134'-0"
REMOVE EXISTING WINDOWS
REMOVE BRICK TO RETOOTH IN NEW
BULLNOSE BRICK AND PROPPER AVB
INTERGRATION WITH NEW WINDOW
REMOVE PRECAST SILL
NOTES TYPICAL FOR ALL WINDOW OPENINGS
REMOVE BRICK COURSING AS REQUIRED TO
INSTAL NEW WEEPS AND THROUGHWALL
FLASHING
PROVIDE SHORING FOR BRICK COURSING
ABOVE AS REQ'D
APPROXIMATE LOCATION OF FINISHED EXTERIOR GRADE
SIDEWALK SLOPES AROUND BUILDING, V.I.F.
EXISTING LOOSE LINTLE TO
REMAIN, FIELD VERIFY CONDITION
AND REFINISH AS NEEDED
PROPERTY OF THE UNITED STATES AIR FORCE
B1994
CONCEPT DESIGN
SI
ZE
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
IS
SU
E
D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
D
EP
AR
TM
EN
T
O F
TH
E
AI
R
F O
R C
E
AI
R F
O R
C E
M
AT
ER
IA
L C
O M
M
AN
D th A
IR
B
AS
E
G R
O U
P/ C
E
BA
SE
C
IV
IL
E N
G
IN
EE
R
IN
G
D
IV
IS
IO
N
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EP
AI
R
(S U
ST
AI
N ) C
H
IL
D D
EV
EL
O
PM
EN
T
C
EN
D
IN
G
SHEET IDENTIFICATION
H
AN
SC
O
M A
FB
, M
A
SM
M
A
SM
M
A
SM
M
A
SM
M
A
AN
SI
-D
1 2 7 8 9 103 4 5 6
A
B
C
D
E
F
G
66 AIR GROUPTH
BASE
SY
M
M
ES
M A
IN
I &
M cK
EE
A
SS
O
C
IA
TE
S
M as sa ch us et ts A ve C am br id ge
, M as sa ch us
P:
7.
7.
U
D Y
- N O
T
N
ST
R U
C
TI
O N
M
XR
D
7-
/0
9/
AD-201
D
EM
O
EL
EV
AT
IO
N S
- P R
ES
C
H O
O L
SCALE: 1/8" = 1'-0"
PRESCHOOL - DEMO - WESTC6
SCALE: 1/8" = 1'-0"
PRESCHOOL - DEMO - SOUTHD1
SCALE: 1/8" = 1'-0"
PRESCHOOL - DEMO - NORTHF1
SCALE: 1/8" = 1'-0"
PRESCHOOL - DEMO - EASTC1
KEYNOTE LEGEND
REFER TO DBRFP PART 3 FOR ADDITIONAL SCOPING INFORMATION
KEY VALUE KEYNOTE TEXT
F201002.A REMOVE BOTTOM COURSES OF BRICK DOWN TO FOUNDATION AS
REQUIRED TO INSTALL WEEP AND THROUGH WALL FLASHING.
F201002.B REMOVE EXTERIOR WINDOWS AND LOUVERS. REMOVE PRECAST
WINDOW SILLS. REMOVE EXISTING SUBSTRATE NOT SUITABLE FOR
WINDOW REPLACEMENT.
F201002.C REMOVE EXTERIOR HOLLOW METAL MAN DOORS AND FRAMES, REMOVE
AND REPLACE THRESHOLDS.
F201002.E REMOVE ALUMINUM SIDING THROUGHOUT.
F201002.I REMOVE MECHANICAL UNIT SCREEN, PAD AND DUCTWORK ENCLOSURES
F201003.A REMOVE GUTTERS AND FASCIA ASSEMBLY
SCALE: 1/2" = 1'-0"
TYPICAL WINDOW DEMOD7
G E D.3D.2E.2
TOS - EAVE
143'-3 3/4"
TOS - PART DAY
PRESCHOOL
159'-8 1/4"
F201002.B
F201002.E
F201003.A
F201003.A
F201002.A
1ST FLOOR
134'-0"
GED.3 E.2
TOS - EAVE
143'-3 3/4"
TOS - PART DAY
PRESCHOOL
159'-8 1/4"
F201002.B
F201002.E
F201003.A
F201002.A
F201002.I
1ST FLOOR
134'-0"
134 6 7 1011
TOS - EAVE
143'-3 3/4"
TOS - PART DAY
PRESCHOOL
159'-8 1/4"
F201002.B
F201002.C
F201002.I
F201002.I
1ST FLOOR
134'-0"
13 4671011
TOS - EAVE
143'-3 3/4"
TOS - PART DAY
PRESCHOOL
159'-8 1/4"
F201002.B
F201002.I
F201002.I
F201003.A
F201002.E
PROPERTY OF THE UNITED STATES AIR FORCE
B1994
CONCEPT DESIGN
SI
ZE
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
IS
SU
E
D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
D
EP
AR
TM
EN
T
O F
TH
E
AI
R
F O
R C
E
AI
R F
O R
C E
M
AT
ER
IA
L C
O M
M
AN
D th A
IR
B
AS
E
G R
O U
P/ C
E
BA
SE
C
IV
IL
E N
G
IN
EE
R
IN
G
D
IV
IS
IO
N
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EP
AI
R
(S U
ST
AI
N ) C
H
IL
D D
EV
EL
O
PM
EN
T
C
EN
D
IN
G
SHEET IDENTIFICATION
H
AN
SC
O
M A
FB
, M
A
SM
M
A
SM
M
A
SM
M
A
SM
M
A
AN
SI
-D
1 2 7 8 9 103 4 5 6
A
B
C
D
E
F
G
66 AIR GROUPTH
BASE
SY
M
M
ES
M A
IN
I &
M cK
EE
A
SS
O
C
IA
TE
S
M as sa ch us et ts A ve C am br id ge
, M as sa ch us
P:
7.
7.
U
D Y
- N O
T
N
ST
R U
C
TI
O N
M
XR
D
7-
/0
9/
AD-202
D
EM
O
EL
EV
AT
IO
N S
- P
AR
T D
AY
PR
ES
C
H O
O L
SCALE: 1/8" = 1'-0"
PART DAY PRESCHOOL - DEMO - NORTHF1 SCALE: 1/8" = 1'-0"
PART DAY PRESCHOOL - DEMO - SOUTHF4
SCALE: 1/8" = 1'-0"
PART DAY PRESCHOOL - DEMO - EASTC1
SCALE: 1/8" = 1'-0"
PART DAY PRESCHOOL - DEMO - WESTA1
KEYNOTE LEGEND
REFER TO DBRFP PART 3 FOR ADDITIONAL SCOPING INFORMATION
KEY VALUE KEYNOTE TEXT
F201002.A REMOVE BOTTOM COURSES OF BRICK DOWN TO FOUNDATION AS
REQUIRED TO INSTALL WEEP AND THROUGH WALL FLASHING.
F201002.B REMOVE EXTERIOR WINDOWS AND LOUVERS. REMOVE PRECAST
WINDOW SILLS. REMOVE EXISTING SUBSTRATE NOT SUITABLE FOR
WINDOW REPLACEMENT.
F201002.C REMOVE EXTERIOR HOLLOW METAL MAN DOORS AND FRAMES, REMOVE
AND REPLACE THRESHOLDS.
F201002.E REMOVE ALUMINUM SIDING THROUGHOUT.
F201002.I REMOVE MECHANICAL UNIT SCREEN, PAD AND DUCTWORK ENCLOSURES
F201003.A REMOVE GUTTERS AND FASCIA ASSEMBLY
E D.3F E.2 DG.1
TOS - EAVE
143'-3 3/4"
TOS ADMIN
159'-2 3/4"
F201002.B
F201002.H
1ST FLOOR
134'-0"
ED.3 FE.2D G.1
TOS - EAVE
143'-3 3/4"
TOS ADMIN
159'-2 3/4"
F201002.B
F201002.C
1ST FLOOR
134'-0"
16 21 2315 17 20 221914.9
TOS - EAVE
143'-3 3/4"
TOS ADMIN
159'-2 3/4"
F201002.B
F201002.J
1ST FLOOR
134'-0"
162123 15172022 19 14.9
TOS - EAVE
143'-3 3/4"
TOS ADMIN
159'-2 3/4"
F201002.B
F201002.C
PROPERTY OF THE UNITED STATES AIR FORCE
B1994
CONCEPT DESIGN
SI
ZE
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
IS
SU
E
D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
D
EP
AR
TM
EN
T
O F
TH
E
AI
R
F O
R C
E
AI
R F
O R
C E
M
AT
ER
IA
L C
O M
M
AN
D th A
IR
B
AS
E
G R
O U
P/ C
E
BA
SE
C
IV
IL
E N
G
IN
EE
R
IN
G
D
IV
IS
IO
N
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EP
AI
R
(S U
ST
AI
N ) C
H
IL
D D
EV
EL
O
PM
EN
T
C
EN
D
IN
G
SHEET IDENTIFICATION
H
AN
SC
O
M A
FB
, M
A
SM
M
A
SM
M
A
SM
M
A
SM
M
A
AN
SI
-D
1 2 7 8 9 103 4 5 6
A
B
C
D
E
F
G
66 AIR GROUPTH
BASE
SY
M
M
ES
M A
IN
I &
M cK
EE
A
SS
O
C
IA
TE
S
M as sa ch us et ts A ve C am br id ge
, M as sa ch us
P:
7.
7.
U
D Y
- N O
T
N
ST
R U
C
TI
O N
M
XR
D
7-
/0
9/
AD-203
D
EM
O
EL
EV
AT
IO
N S
- A D
M
IN
SCALE: 1/8" = 1'-0"
ADMIN - DEMO - NORTHF1
SCALE: 1/8" = 1'-0"
ADMIN - DEMO - SOUTHD1
SCALE: 1/8" = 1'-0"
ADMIN - DEMO - EASTB1 SCALE: 1/8" = 1'-0"
ADMIN - DEMO - WESTB6
KEYNOTE LEGEND
REFER TO DBRFP PART 3 FOR ADDITIONAL SCOPING INFORMATION
KEY VALUE KEYNOTE TEXT
F201002.B REMOVE EXTERIOR WINDOWS AND LOUVERS. REMOVE PRECAST
WINDOW SILLS. REMOVE EXISTING SUBSTRATE NOT SUITABLE FOR
WINDOW REPLACEMENT.
F201002.C REMOVE EXTERIOR HOLLOW METAL MAN DOORS AND FRAMES, REMOVE
AND REPLACE THRESHOLDS.
F201002.H REMOVE MASONRY SCREEN WALL FOR RECONSTRUCTION, SALVAGE
BRICK.
F201002.J REMOVE CLOCKTOWER WINDOWS AND SIDING, REPLACE IN KIND
TU S Q N L J.1
H
TOS - EAVE
143'-3 3/4"
TOS - TODDLERS
157'-6 1/4"
F201002.B
F201002.C
1ST FLOOR
134'-0"
T USQNLJ.1
HG.1
M PK R
TOS - EAVE
143'-3 3/4"
TOS - TODDLERS
157'-6 1/4"
1ST FLOOR
134'-0"
TOS - EAVE
143'-3 3/4"
TOS - TODDLERS
157'-6 1/4"
F201002.E
F201002.I
F201002.I
1ST FLOOR
134'-0"
TOS - EAVE
143'-3 3/4"
TOS - TODDLERS
157'-6 1/4"
PROPERTY OF THE UNITED STATES AIR FORCE
B1994
CONCEPT DESIGN
SI
ZE
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
IS
SU
E
D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
D
EP
AR
TM
EN
T
O F
TH
E
AI
R
F O
R C
E
AI
R F
O R
C E
M
AT
ER
IA
L C
O M
M
AN
D th A
IR
B
AS
E
G R
O U
P/ C
E
BA
SE
C
IV
IL
E N
G
IN
EE
R
IN
G
D
IV
IS
IO
N
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EP
AI
R
(S U
ST
AI
N ) C
H
IL
D D
EV
EL
O
PM
EN
T
C
EN
D
IN
G
SHEET IDENTIFICATION
H
AN
SC
O
M A
FB
, M
A
SM
M
A
SM
M
A
SM
M
A
SM
M
A
AN
SI
-D
1 2 7 8 9 103 4 5 6
A
B
C
D
E
F
G
66 AIR GROUPTH
BASE
SY
M
M
ES
M A
IN
I &
M cK
EE
A
SS
O
C
IA
TE
S
M as sa ch us et ts A ve C am br id ge
, M as sa ch us
P:
7.
7.
U
D Y
- N O
T
N
ST
R U
C
TI
O N
M
XR
D
7-
/0
9/
AD-204
D
EM
O
EL
EV
AT
IO
N S
- T O
D D
LE
R
S
SCALE: 1/8" = 1'-0"
TODDLERS - DEMO - NORTHD1 SCALE: 1/8" = 1'-0"
TODDLERS - DEMO - SOUTHD5
SCALE: 1/8" = 1'-0"
TODDLERS - DEMO - EASTB1 SCALE: 1/8" = 1'-0"
TODDLERS - DEMO - WESTB5
KEYNOTE LEGEND
REFER TO DBRFP PART 3 FOR ADDITIONAL SCOPING INFORMATION
KEY VALUE KEYNOTE TEXT
F201002.B REMOVE EXTERIOR WINDOWS AND LOUVERS. REMOVE PRECAST
WINDOW SILLS. REMOVE EXISTING SUBSTRATE NOT SUITABLE FOR
WINDOW REPLACEMENT.
F201002.C REMOVE EXTERIOR HOLLOW METAL MAN DOORS AND FRAMES, REMOVE
AND REPLACE THRESHOLDS.
F201002.E REMOVE ALUMINUM SIDING THROUGHOUT.
F201002.I REMOVE MECHANICAL UNIT SCREEN, PAD AND DUCTWORK ENCLOSURES
N J.1 H G.1MP KR
TOS - EAVE
143'-3 3/4"
TOS - INFANTS
154'-5 3/4"
F201002.B
F201002.C
F201003.A
1ST FLOOR
134'-0"
NJ.1HG.1 M PK R
TOS - EAVE
143'-3 3/4"
TOS - INFANTS
154'-5 3/4"
F201002.B
F201002.C
1ST FLOOR
134'-0"
21 23 2417 2219
TOS - EAVE
143'-3 3/4"
TOS - INFANTS
154'-5 3/4"
F201002.B
F201002.D
1ST FLOOR
134'-0"
212324 19
TOS - EAVE
143'-3 3/4"
TOS - INFANTS
154'-5 3/4"
F201002.B
B2030.A
F201002.A
F201002.D
PROPERTY OF THE UNITED STATES AIR FORCE
B1994
CONCEPT DESIGN
SI
ZE
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
IS
SU
E
D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
D
EP
AR
TM
EN
T
O F
TH
E
AI
R
F O
R C
E
AI
R F
O R
C E
M
AT
ER
IA
L C
O M
M
AN
D th A
IR
B
AS
E
G R
O U
P/ C
E
BA
SE
C
IV
IL
E N
G
IN
EE
R
IN
G
D
IV
IS
IO
N
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EP
AI
R
(S U
ST
AI
N ) C
H
IL
D D
EV
EL
O
PM
EN
T
C
EN
D
IN
G
SHEET IDENTIFICATION
H
AN
SC
O
M A
FB
, M
A
SM
M
A
SM
M
A
SM
M
A
SM
M
A
AN
SI
-D
1 2 7 8 9 103 4 5 6
A
B
C
D
E
F
G
66 AIR GROUPTH
BASE
SY
M
M
ES
M A
IN
I &
M cK
EE
A
SS
O
C
IA
TE
S
M as sa ch us et ts A ve C am br id ge
, M as sa ch us
P:
7.
7.
U
D Y
- N O
T
N
ST
R U
C
TI
O N
M
XR
D
7-
/0
9/
AD-205
D
EM
O
EL
EV
AT
IO
N S
- I N
FA
N
TS
SCALE: 1/8" = 1'-0"
INFANTS - DEMO - NORTHF1 SCALE: 1/8" = 1'-0"
INFANTS - DEMO - SOUTHF5
SCALE: 1/8" = 1'-0"
INFANTS - DEMO - EASTC1 SCALE: 1/8" = 1'-0"
INFANTS - DEMO - WESTC5
KEYNOTE LEGEND
REFER TO DBRFP PART 3 FOR ADDITIONAL SCOPING INFORMATION
KEY VALUE KEYNOTE TEXT
B2030.A REPLACE (E) DOOR IN KIND. PROVIDE ADDITIONAL HARDWARE AND
TRANSPARENCY REQUIREMENTS INDICATED IN FC 4-740-14F.
F201002.A REMOVE BOTTOM COURSES OF BRICK DOWN TO FOUNDATION AS
REQUIRED TO INSTALL WEEP AND THROUGH WALL FLASHING.
F201002.B REMOVE EXTERIOR WINDOWS AND LOUVERS. REMOVE PRECAST
WINDOW SILLS. REMOVE EXISTING SUBSTRATE NOT SUITABLE FOR
WINDOW REPLACEMENT.
F201002.C REMOVE EXTERIOR HOLLOW METAL MAN DOORS AND FRAMES, REMOVE
AND REPLACE THRESHOLDS.
F201002.D REMOVE STOREFRONT ASSEMBLIES INCLUDING DOORS, GLAZING,
FRAMING AND METAL PANELS, PREP SLAB AND HEAD CONDITION FOR
NEW ASSEMBLIES.
F201003.A REMOVE GUTTERS AND FASCIA ASSEMBLY
G
E
D.3 D.2
D.1
C
B
A
1 2 3 5 8 9
4 6 7 10
872 SF
PRE-SCHOOL
866 SF
PRE-SCHOOL
929 SF
PRE-SCHOOL
976 SF
PRE-SCHOOL
911 SF
PRE-SCHOOL
872 SF
PRE-SCHOOL
784 SF
PRE-TODDLER
1,035 SF
PART DAY
PRE-SCHOOL
1,034 SF
PART DAY
PRE-SCHOOL
STORAGE
RESTROOM
RESTROOM
STORAGE
RESTROOM
STORAGE
STORAGE
RESTROOM
STORAGE
RESTROOM
RESTROOM
STORAGE
STORAGE
STORAGE
RESTROOM
RESTROOM
STORAGE
RESTROOM
RESTROOM
STORAGE
STORAGE
STORAGE
STAFF
WORKROOM
CORRIDOR
CORRIDOR
4'-7"5' -7
6' -0
5' -6
6' -0
5' -6
5' -6
/A1 A-101B
4.1.1.6
4.1.1.6
4.1.1.6
4.1.1.9
4.1.1.1
4.1.1.6
4'-6"
4.1.1.6
4.1.1.11
50 SF
STORAGE
107.1
REF.
FOOD
PREP
FUTURE
TOILET
CHILD HAND WASH
TRASH CHUTE
ADULT
HAND WASH
FOOD PREP
DOUBLE SINK
UPPER
CABINETS
CHILD HAND
WASH
TRASH
CABINET
TOILET
PARTITION.
SINGLE SINK
TRASH CHUTE
SHELVING
STAFF
LOCKERS
RECESSED DIAPER
CUBBY
LAUNDRY CHUTE
EX
TE
R
IO
R W
AL
L
'-3
" N
EW
O
PA
Q U
E
CONSTRUCTION PLAN GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
ALL DIMENSIONS ARE NOMINAL U.N.O.
ALL DIMENSIONS ARE TO FACE OF FINISH U.N.O.
DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. IN CASE OF CONFLICT, CONSULT THE
CONTRACTING OFFICER.
REVIEW LAYOUTS FOR PARTITIONS IN FIELD WITH CONTRACTING OFFICER PRIOR TO START OF
CONSTRUCTION.
PENETRATIONS THROUGH PARTITION CONSTRUCTION ABOVE FINISHED CEILING SHALL BE
EFFECTIVELY SEALED TO PREVENT SOUND LEAKAGE AT ACOUSTICAL PARTITIONS.
ALL PARTITIONS SHALL BE PLUMB, SQUARE, STRAIGHT, AND PARALLEL OR PERPENDICULAR TO THE
CLOSEST GRID, U.N.O.
GLASS SPANDREL PANELS SHALL BE COVERED ON THE INTERIOR SIDE OF THE BUILDING WITH THE
ADJACENT PARTITION TYPE, U.N.O.
COMPLETELY SURROUND RECESSED EQUIPMENT AND DEVICES IN RATED WALLS WITH TYPE X GYP BD
AS REQUIRED TO MAINTAIN RATING.
INDICATED PARTITION TYPES ARE CONTINUOUS ABOVE/BELOW DOOR AND WINDOW OPENINGS AND AROUND CORNERS UNTIL INTERSECTION WITH A DIFFERENT TYPE. WHERE PARTITIONS INTERSECT AT
“T”, THE INDICATED TYPE RUNS ACROSS THE “T” U.N.O.
DO NOT LOCATE OUTLET BOXES (INCLUDING TELECOM/DATA AND ELECTRICAL) OPPOSITE ONE
ANOTHER IN ACOUSTICALLY (STC) RATED PARTITIONS. LOCATE OUTLETS AT LEAST ONE STUD BAY APART. SEAL THE OUTLET BOXES WITH PUTTY PADS AND CAULK THE PERIMETER USING ACOUSTIC
SEALANT. AT RATED PARTITIONS, LOCATE OUTLET BOXES 24-INCHES APART, MIN.
ON CONTINUOUS WALL SURFACES WHERE CONSTRUCTION INVOLVES MORE THAN ONE MATERIAL,
FINISH, OR MATERIAL THICKNESS, LOCATE FRAMING SO THE FINISHED FACES ALIGN, U.N.O.
ALL GYPSUM BOARD PARTITIONS WHETHER EXPOSED TO VIEW OR NOT SHALL HAVE CONTROL JOINTS.
SEE INTERIOR ELEVATIONS FOR LOCATION. PROVIDE PER MAXIMUM SPACING OF 30 FEET O.C.
PROVIDE AND COORDINATE PLACEMENT OF FIRE RATED BLOCKING AT ALL LOCATIONS OF ITEMS TO BE MOUNTED TO WALLS OR CEILINGS THROUGHOUT LIMIT OF WORK, PRIOR TO CLOSING WALLS U.N.O.
REFER TO REFLECTED CEILING PLANS (A-151A THRU A-151C) FOR CEILING MATERIALS AND HEIGHTS.
REFER TO SHEET A-701 FOR ROOM FINISH SCHEDULE.
CONSTRUCTION SYMBOLS LEGEND
17 WINDOW TAG - INTERIOR
EXISTING WALL
EXISTING DOOR
TO REMAIN
NEW WALL
NEW DOOR
(SEE DOOR SCHEDULE)
G3A PARTITION TYPE
ROOM TAG
ROOM NAME
LCD SCREEN
AREA
DOOR NUMBER
LOCATION OF NEW
FLOORING
LOCATION OF NEW
MILLWORK
04 8 16268
SCALE: 1/8"=1'-0"
PROPERTY OF THE UNITED STATES AIR FORCE
B1994
CONCEPT DESIGN
SI
ZE
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
IS
SU
E
D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
D
EP
AR
TM
EN
T
O F
TH
E
AI
R
F O
R C
E
AI
R F
O R
C E
M
AT
ER
IA
L C
O M
M
AN
D th A
IR
B
AS
E
G R
O U
P/ C
E
BA
SE
C
IV
IL
E N
G
IN
EE
R
IN
G
D
IV
IS
IO
N
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EP
AI
R
(S U
ST
AI
N ) C
H
IL
D D
EV
EL
O
PM
EN
T
C
EN
D
IN
G
SHEET IDENTIFICATION
H
AN
SC
O
M A
FB
, M
A
SM
M
A
SM
M
A
SM
M
A
SM
M
A
AN
SI
-D
1 2 7 8 9 103 4 5 6
A
B
C
D
E
F
G
66 AIR GROUPTH
BASE
SY
M
M
ES
M A
IN
I &
M cK
EE
A
SS
O
C
IA
TE
S
M as sa ch us et ts A ve C am br id ge
, M as sa ch us
P:
7.
7.
U
D Y
- N O
T
N
ST
R U
C
TI
O N
A
B
KEYPLAN
C
M
XR
D
7-
/0
9/
A-101A
FI
R
ST
F
LO
O
R C
O N
ST
. P
LA
N
PA
R T
A
SCALE: 1/8" = 1'-0"
1ST FLOOR CONSTRUCTION PLAN - PART AA1
KEYNOTE LEGEND
REFER TO DBRFP PART 3 FOR ADDITIONAL SCOPING INFORMATION
KEY VALUE KEYNOTE TEXT
4.1.1.1 RESTROOMS LOCATED IN THE CHILD ACTIVITY ROOMS DO NOT MEET ACCESSIBILITY
REQUIREMENTS, REVISE PARTITION LAYOUT AS REQUIRED TO PROVIDE ACCESSIBLE
FIXTURES. NOTE THAT ACCESSIBILITY REQUIREMENTS FOR CHILDREN ARE DIFFERENT
THEN FOR ADULTS. SALVAGE ALL DECORATIVE TRIM FOR REINSTALL.
4.1.1.6 INSTALL NEW DIAPER CHANGING STATIONS AS SPECIFIED IN FC 4-740-14F.
4.1.1.9 PROVIDE NEW DOUBLE DOORS ON MAGNETIC HOLD OPENS TO SATISFY ACTIVE SHOOTER
REQUIREMENTS. REFER TO RFP PART 3 C102008 ACTIVE SHOOTER PREVENTION DOORS
4.1.1.11 CONVERT EXISTING MULTI-PURPOSE ROOM TO NEW 0-24MONTH CHILD ACTIVITY ROOM.
PRELIMINARY MILLWORK AND PLUMBING LAYOUT PROVIDED, REVIEW FINAL LAYOUT WITH
AFSVC AND FC 4-740-14 REQUIREMENTS - REFER TO PART 3 PROJECT PROGRAM, FOR
ADDITIONAL INFORMATION
I
I
E
D.3
F F
E.2 E.2
D D
15 17 20 22
14.9
872 SF
PRE-SCHOOL
784 SF
PRE-TODDLER
1,034 SF
PART DAY
PRE-SCHOOL
STORAGE
STORAGE
STAFF
WORKROOM
CHILDCARE
COORD.
WING SUP.
STAFF
RESTROOM
145 STORAGE
JAN.
WOMEN'S
ROOM
BREAK
ROOM
ASST. DIR.
OFFICE
DIRECTOR
OFFICE
HEALTH
ROOM
MOTHER'S
ROOM
WING SUP
AND ADMIN
VESTIBULE
RECEPTION/
LOBBY
ELEC. ROOM
MECH. ROOM
COMPUTER
ROOM
COMM.
ROOM
KITCHEN
SERVICE
CORR.
106A
KITCHEN
OFFICE
106B
KITCHEN
STORAGE
106C
CORRIDOR
DISPLAY CASE
WITH GLASS
CORNER.
HEALTH
RESTROOM
152.1
NEW
RECESSED
BOTTLE FILLER
/A1 A-101C
/A1 A-101A 4.1.1.7
B2030.B
4.1.1.4
4.1.1.5
4.1.1.3
4.1.1.2
4.1.1.9
B2010.D
FREEZER
106D
D30.1
D30.1
REFER TO FFE TYPICALS
APPENDIX FOR…
This is the start of the file's text. The full file is on GovTribe.