Meissner SA 6 22 21.pdf
PDF 1 MB Posted
- Solicitation number
- S-C05004-00002810
- Issued by
- Coos County, Oregon
About this file
This document is a structural analysis report prepared by FDH Infrastructure Services, LLC for Cushing Civil Engineers regarding a 152 ft. self-support tower located in Columbia County, Oregon. The analysis was conducted to determine if the tower structure is adequate to support the proposed antenna loads in accordance with ANSI/TIA-222-H and the 2019 Oregon Structural Specialty Code. The tower is designed for a basic wind speed of 130 mph without ice and 30 mph with 1" of ice, and is classified as a Risk Category IV structure. The report provides details on the tower components, member capacities, and maximum dish rotations. To ensure the tower meets the current analysis standards, the report recommends that the feed lines be installed as shown in the appendix.
The report does not provide any information on pricing, set-asides, incumbents, funding sources, or contract terms. The structural analysis appears to be part of a larger civil construction project for a new wireless site, but the full details of the state and local contract opportunity are not included in this document.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Report Meissner CCE BMC 200015 SRT.pdf | ||
| Columbia911 ITB Meissner.docx | DOCX document | |
| RFP Evaluation Form Meisner 3.docx | DOCX document | |
| Report Meissner CCE BMC 200015 GEO.pdf | ||
| Intent to Award~16.xlsx | XLSX spreadsheet | |
| Meissner Pricing Schedule 2.xlsx | XLSX spreadsheet | |
| Columbia 911 Agreement Final 04_2022.docx | DOCX document | |
| 4. Meissner Final Construction Drawings 4-7-2021.pdf | ||
| Pumpkin Center Building Drawing~1.pdf | ||
| Wireless Construction SOW Meissner 04_2022.docx | DOCX document | |
| Pumpkin Center Building Drawing~2.pdf | ||
| Special Inspection Short form 2016 Signed.PDF | ||
| Meisner R 1 For Construction.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Document No. ENG-RPT-10200 Revision Date: 03/12/2015
Structural Analysis for
Cushing Civil Engineers
152 ft. Self-Support Tower
Site Name: Meissner
Site Coordinates: N 45° 58' 13.36'', W 122° 59' 57.82''
FDH Infrastructures Services, LLC Project Number PR-005358 (R.1)
Analysis Results Tower Components 69.4% Sufficient
Dish Rotation Results (60 mph)
Centerline (ft) Dish Tilt (deg) Twist (deg)
80.0 (1) Cambium ePMP Force 0.0934 0.0047
Prepared By: Reviewed By:
Deepak Reddy Devulapally, EIT
Project Engineer I
Dennis D. Abel, PE Chief Engineer
OR PE License No. 85711PE
FDH Infrastructures Services, LLC 6521 Meridien Drive Raleigh, NC 27616
(919) 755-1012 Structural@FDH-IS.com
June 22, 2021
Prepared pursuant to ANSI/TIA-222-H Structural Standard for Antenna Supporting Structures, Antennas and Small Wind Turbine Support Structures and the 2019 Oregon
Structural Specialty Code (2018 IBC)
Structural Analysis Report
TABLE OF CONTENTS
EXECUTIVE SUMMARY
Conclusions
Recommendations
APPURTENANCE LISTING
RESULTS
GENERAL COMMENTS
LIMITATIONS
APPENDIX
EXECUTIVE SUMMARY
At the request of Cushing Civil Engineers, FDH Infrastructure Services, LLC performed a structural analysis of the proposed 152 ft. Self-Support Tower located in Columbia County, OR to determine whether the structure is structurally adequate to support both the proposed loads pursuant to the Structural Standard for Antenna Supporting Structures, Antennas and Small Wind Turbine Support Structures, ANSI/TIA-222-H and the 2019 Oregon Structural Specialty Code (2018 IBC). Information pertaining to the existing/proposed antenna loading, mount geometry, and member sizes was obtained from:
Source Document Type Reference Date
ROHN Products LLC Tower Manufacturer Drawings Drawing No. C870699 September 02,1987 ROHN Section Assembly Drawings Drawing No. A931401 June 9, 1993 ROHN Section Assembly Drawings Drawing No. A941158 March 23, 1994 Radian Tower Design Drawings Radian No. 0602270 October 20, 2005
Johnson Broderick Engineering Previous Structural Analysis Project No. 18051.01 March 9, 2018 Black Mountain Consulting LLC Geotechnical Report Project No. 200015-GEO March 22, 2020
Orion Geomatics Survey Certification Site Name. Meissner May 11, 2020 Email Loading info Site Name. Meissner February 23, 2021
Cushing Civil Engineers
The ultimate design wind speed per 2019 Oregon Structural Specialty Code (2018 IBC) is 130 mph without ice and 30 mph with 1” radial ice. Ice is considered to increase in thickness with height. Furthermore, this structure was analyzed as a Risk Category IV structure in Exposure Category C using Topographic Category 5 and Spectral Response Accelerations of Ss=
0.881 and S1= 0.439.
Conclusions
With the antenna configuration from Email outlined in Table 1, we have determined the tower stress level to be Sufficient pursuant to the requirements stipulated by to the ANSI/TIA-222-H, Structural Standard for Antenna Supporting Structures, Antennas and Small Wind Turbine Support Structures and the 2019 Oregon Structural Specialty Code (2018 IBC) provided the Recommendation(s) listed below are satisfied. However, the foundation was not considered in the analysis, as such, we cannot comment on the capacity of the foundation at this time. For a more detailed description of the analysis of the tower, see the Results section of this report.
Our assessment has been made assuming all information provided to FDH Infrastructure Services, LLC is accurate and that the tower have been properly erected and maintained.
Recommendations
To ensure the requirements of the current analysis standards are met with the antenna configuration in place per Table 1, we have the following recommendation(s):
1. Feed lines to be installed as shown in Figure 1 in the Appendix.
APPURTENANCE LISTING
The antennas and equipment, with their corresponding feed lines, considered for this analysis are shown in Table 1. If the actual layout determined in the field deviates from the layout, FDH Infrastructure Services, LLC should be contacted to perform a revised analysis.
Table 1 - Appurtenance Loading
Final Loading:
Antenna Elevation
(ft.)
Description Feed Lines Carrier
Mount Centerline Elevation
(ft.)
Mount Type
159.0 (1) Commander Technologies 220-3BN (1) 7/8 - 149.0 3’ Standoff
80.0 (1) Cambium ePMP Force 200 (1) EW63 - 80.0 Direct Tower Mounted
61.5 (1) dbSpectra DS8A03F36U-N (1) 7/8 - 60.0 3’ Standoff
RESULTS
The following member material grades were utilized in the analysis:
Table 2 - Member Material Grade Member Type Steel Grade*
Legs A572-50 Bracing (0’ – 40’) A572-50
Bracing (40’ – 152’) A36 Bolts A325N
* Steel grade assumed unless otherwise noted.
Table 3 and Table 4 display the summary of capacities for the analyzed structure and its additional components. Values greater than 100% indicate locations where the maximum force in the member exceeds its capacity. Table 5 displays the maximum dish rotations at service winds speeds.
If the assumptions outlined in this report differ from actual field conditions, FDH Infrastructure Services, LLC should be contacted to perform a revised analysis. Furthermore, as no information pertaining to the allowable twist and sway requirements for the appurtenances was provided, deflection and rotation were not taken into consideration when performing this analysis.
See the Appendix for detailed modeling information.
Table 3 - Structure Member Capacities Section No. Elevation (ft.) Component Type Size % Capacity Pass / Fail
T1 152 - 140 Leg ROHN 2.5 STD 7.0 Pass T2 140 - 120 Leg ROHN 2.5 STD 39.2 Pass T3 120 - 100 Leg ROHN 2.5 EH 56.0 Pass T4 100 - 80 Leg ROHN 3 EH 61.3 Pass T5 80 - 60 Leg ROHN 4 EH 56.2 Pass T6 60 - 40 Leg ROHN 5 EH 48.2 Pass T7 40 - 20 Leg ROHN 5 EH 59.9 Pass T8 20 - 0 Leg ROHN 6 EHS 69.4 Pass
T1 152 - 140 Diagonal L1 3/4x1 3/4x3/16 8.7
22.3 (b) Pass
T2 140 - 120 Diagonal L2x2x1/4 12.0
28.7 (b) Pass
T3 120 - 100 Diagonal L2x2x1/4 11.5
24.3 (b) Pass
T4 100 - 80 Diagonal L2x2x1/4 23.4
32.3 (b) Pass
T5 80 - 60 Diagonal L2 1/2x2 1/2x3/16 33.5
50.4 (b) Pass
T6 60 - 40 Diagonal L2 1/2x2 1/2x3/16 53.0
61.9 (b) Pass
T7 40 - 20 Diagonal L2 1/2x2 1/2x1/4 64.5 Pass T8 20 - 0 Diagonal L3x3x1/4 67.8 Pass
T1 152 - 140 Top Girt L1 3/4x1 3/4x3/16 0.5
0.5 (b) Pass
Table 4 – Additional Structure Component Capacities
Elevation (ft.) Component % Capacity Pass / Fail
0 Anchor Rods 40.8 Pass
Table 5 - Maximum Dish Rotations at Service Wind Speeds
Centerline Elevation (ft.) Dish Tilt (deg)* Twist (deg)*
80.0 (1) Cambium ePMP Force 200 0.0934 0.0047 *Allowable tilt and twist to be reviewed by the carrier.
GENERAL COMMENTS
This engineering analysis is based upon the theoretical capacity of the structure. It is not a condition assessment of the tower and its foundation. It is the responsibility of Cushing Civil Engineers to verify that the tower modeled and analyzed is the correct structure (with accurate antenna loading information) modeled. If there are substantial modifications to be made or the assumptions made in this analysis are not accurate, FDH Infrastructure Services, LLC should be notified immediately to perform a revised analysis.
LIMITATIONS
All opinions and conclusions are considered accurate to a reasonable degree of engineering certainty based upon the evidence available at the time of this report. All opinions and conclusions are subject to revision based upon receipt of new or additional/updated information. All services are provided exercising a level of care and diligence equivalent to the standard and care of our profession. No other warranty or guarantee, expressed or implied, is offered. Our services are confidential in nature and we will not release this report to any other party without the client’s consent. The use of this engineering work is limited to the express purpose for which it was commissioned and it may not be reused, copied, or distributed for any other purpose without the written consent of FDH Infrastructure Services, LLC.
APPENDIX
FIGURE 1 – ASSUMED FEED LINE LAYOUT
FDH-IS
FDH Infrastructure Services 6521 Meridien Drive
Raleigh, North Carolina 27616 Phone: (919) 755-1012
FAX: (919) 755-1031
Job: Meisnner Project: PR-005358 Client: Cushing Civil Engineers Drawn by: Deepak Devulapally App'd:
Code: TIA-222-H Date: 06/22/21 Scale: NTS Path:
C:\Users\deepak.devulapally\Desktop\Assigned Projects\Meisnner\PR-005358_SA_Carrier\R.1\Analysis\ReportedTower\Meisnner Tower Site.eri
Dwg No. E-1
152.0 ft
140.0 ft
120.0 ft
100.0 ft
80.0 ft
60.0 ft
40.0 ft
20.0 ft
0.0 ft
REACTIONS - 130 mph WIND TORQUE 6 kip-ft
36 K
SHEAR
2517 kip-ft
MOMENT
15 K
AXIAL
30 mph WIND - 1.0000 in ICE TORQUE 1 kip-ft
3 K
SHEAR
259 kip-ft
MOMENT
42 K
AXIAL
SHEAR: 18 K
UPLIFT: -147 K
SHEAR: 21 K
DOWN: 177 K
MAX. CORNER REACTIONS AT BASE:
ARE FACTORED
ALL REACTIONS
S e ct io n
T
T
T
T
T
T
T
T
L g s R
O H
N
.5 S
T D
R O
H N
.5
E H
R O
H N
E
H R
O H
N
E H
R O
H N
E
H R
O H
N
E H g
G ra d e
A
-5
D ia g o n a ls
L
/4 x1
/4 x3
/1
L x2 x1
/4 L
/2 x2
/2 x3 /1
L
/2 x2
/2 x1 /4
L x3 x1
/4 g o n a l G ra d e A
A o p
G ir ts L
/4 x1
/4 x3 /1
N
.A
F a ce
W id th ft
.5
.5
.5
.7
.8
.8
.9
P an el s ft
.6
W ig h t
(K
0.
0.
1.
1.
1.
2.
2.
2.
.2
220-3BN 149 Side Arm Mount [SO 305-1] 149 EPMP FORCE 200 5GHZ 80 Side Arm Mount [SO 305-1] 60 DS8A03F36U-N 60DESIGNED APPURTENANCE LOADING
TYPE TYPEELEVATION ELEVATION
220-3BN 149
Side Arm Mount [SO 305-1] 149
EPMP FORCE 200 5GHZ 80
Side Arm Mount [SO 305-1] 60
DS8A03F36U-N 60
MATERIAL STRENGTH
GRADE GRADEFy FyFu Fu
A572-50 50 ksi 65 ksi A36 36 ksi 58 ksi
TOWER DESIGN NOTES
1. Tower is located in Columbia County, Oregon.
2. Tower designed for Exposure C to the TIA-222-H Standard.
3. Tower designed for a 130 mph basic wind in accordance with the TIA-222-H Standard.
4. Tower is also designed for a 30 mph basic wind with 1.00 in ice. Ice is considered to increase in thickness with height.
5. Deflections are based upon a 60 mph wind.
6. Tower Risk Category IV.
7. Topographic Category 5 with Crest Height of 985.00 ft
8. TOWER RATING: 69.4%
ttnnxxTToowweerr Job
Meisnner
Page
FDH Infrastructure Services 6521 Meridien Drive
Project
PR-005358
Date
14:35:23 06/22/21 Raleigh, North Carolina 27616
Phone: (919) 755-1012
FAX: (919) 755-1031
Client Cushing Civil Engineers
Designed by
Deepak Devulapally
Tower Input Data
The main tower is a 3x free standing tower with an overall height of 152.00 ft above the ground line.
The base of the tower is set at an elevation of 0.00 ft above the ground line.
The face width of the tower is 4.58 ft at the top and 16.92 ft at the base.
This tower is designed using the TIA-222-H standard.
The following design criteria apply:
Tower is located in Columbia County, Oregon.
Tower base elevation above sea level: 1367.00 ft.
Basic wind speed of 130 mph.
Risk Category IV.
Exposure Category C.
Crest Height: 985.00 ft.
Rigorous Topographic Factor Procedure for wind speed-up calculations is used.
Topographic Feature: Continuous Ridge.
Slope Distance L: 4978.00 ft.
Distance from Crest x: 0.00 ft.
Horizontal Distance Downwind: No.
Nominal ice thickness of 1.0000 in.
Ice thickness is considered to increase with height.
Ice density of 56 pcf.
A wind speed of 30 mph is used in combination with ice.
Temperature drop of 50 °F.
Deflections calculated using a wind speed of 60 mph.
A non-linear (P-delta) analysis was used.
Pressures are calculated at each section.
Stress ratio used in tower member design is 1.
Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered.
Options
Consider Moments - Legs Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules Consider Moments - Horizontals Assume Legs Pinned √ Calculate Redundant Bracing Forces Consider Moments - Diagonals Assume Rigid Index Plate Ignore Redundant Members in FEA Use Moment Magnification √ Use Clear Spans For Wind Area SR Leg Bolts Resist Compression
√ Use Code Stress Ratios √ Use Clear Spans For KL/r All Leg Panels Have Same Allowable √ Use Code Safety Factors - Guys Retension Guys To Initial Tension Offset Girt At Foundation Escalate Ice √ Bypass Mast Stability Checks √ Consider Feed Line Torque Always Use Max Kz √ Use Azimuth Dish Coefficients √ Include Angle Block Shear Check Use Special Wind Profile √ Project Wind Area of Appurt. Use TIA-222-H Bracing Resist. Exemption
√ Include Bolts In Member Capacity Autocalc Torque Arm Areas Use TIA-222-H Tension Splice Exemption Leg Bolts Are At Top Of Section Add IBC .6D+W Combination Poles Secondary Horizontal Braces Leg √ Sort Capacity Reports By Component Include Shear-Torsion Interaction Use Diamond Inner Bracing (4 Sided) Triangulate Diamond Inner Bracing Always Use Sub-Critical Flow SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Use Top Mounted Sockets SR Members Are Concentric Ignore KL/ry For 60 Deg. Angle Legs Pole Without Linear Attachments Pole With Shroud Or No Appurtenances Outside and Inside Corner Radii Are
Known
Meisnner
Page
FDH Infrastructure Services 6521 Meridien Drive
Project
PR-005358
Date
14:35:23 06/22/21 Raleigh, North Carolina 27616
Phone: (919) 755-1012
FAX: (919) 755-1031
Client Cushing Civil Engineers
Designed by
Leg B Leg C
Leg A
Fa ce
A Face B
Face C
Triangular To wer
Wind Norma l
Wind 90
Wind 180
Z
X
Tower Section Geometry
Tower Section
Elevation ft
Assembly Database
Description Section Width
Number of
Sections
Length
T1 152.00-140.00 4.58 1 12.00 T2 140.00-120.00 4.58 1 20.00 T3 120.00-100.00 4.58 1 20.00 T4 100.00-80.00 6.58 1 20.00 T5 80.00-60.00 8.59 1 20.00 T6 60.00-40.00 10.70 1 20.00 T7 40.00-20.00 12.82 1 20.00 T8 20.00-0.00 14.83 1 20.00
Tower Section Geometry (cont’d)
Diagonal Spacing
Bracing Type
Has K Brace
End Panels
Has Horizontals
Top Girt Offset in
Bottom Girt
T1 152.00-140.00 4.00 X Brace No No 0.0000 0.0000 T2 140.00-120.00 4.00 X Brace No No 0.0000 0.0000 T3 120.00-100.00 4.00 X Brace No No 0.0000 0.0000 T4 100.00-80.00 5.00 X Brace No No 0.0000 0.0000 T5 80.00-60.00 6.67 X Brace No No 0.0000 0.0000
Meisnner
Page
FDH Infrastructure Services 6521 Meridien Drive
Project
PR-005358
Date
14:35:23 06/22/21 Raleigh, North Carolina 27616
Phone: (919) 755-1012
FAX: (919) 755-1031
Client Cushing Civil Engineers
Designed by
Deepak Devulapally
Tower Section
Diagonal Spacing
Bracing Type
Has K Brace
End Panels
Has Horizontals
Bottom Girt
T6 60.00-40.00 6.67 X Brace No No 0.0000 0.0000 T7 40.00-20.00 6.67 X Brace No No 0.0000 0.0000 T8 20.00-0.00 10.00 X Brace No No 0.0000 0.0000 ft
Leg Type
Size
Grade
Diagonal Type
Diagonal Size
Diagonal Grade
T1 152.00-140.00 Pipe ROHN 2.5 STD A572-50 (50 ksi)
Single Angle L1 3/4x1 3/4x3/16 A36 (36 ksi)
T2 140.00-120.00 Pipe ROHN 2.5 STD A572-50 (50 ksi)
Single Angle L2x2x1/4 A36 (36 ksi)
T3 120.00-100.00 Pipe ROHN 2.5 EH A572-50 (50 ksi)
Single Angle L2x2x1/4 A36 (36 ksi)
T4 100.00-80.00 Pipe ROHN 3 EH A572-50 (50 ksi)
Single Angle L2x2x1/4 A36 (36 ksi)
T5 80.00-60.00 Pipe ROHN 4 EH A572-50 (50 ksi)
Single Angle L2 1/2x2 1/2x3/16 A36 (36 ksi)
T6 60.00-40.00 Pipe ROHN 5 EH A572-50 (50 ksi)
Single Angle L2 1/2x2 1/2x3/16 A36 (36 ksi)
T7 40.00-20.00 Pipe ROHN 5 EH A572-50 (50 ksi)
Single Angle L2 1/2x2 1/2x1/4 A572-50 (50 ksi)
T8 20.00-0.00 Pipe ROHN 6 EHS A572-50 (50 ksi)
Single Angle L3x3x1/4 A572-50 (50 ksi) ft
Bottom Girt Type
Bottom Girt Size
Bottom Girt Grade
T1 152.00-140.00 Single Angle L1 3/4x1 3/4x3/16 A36 (36 ksi)
Solid Round A36 (36 ksi)
Gusset Area
(per face) ft2
Thickness
Gusset Grade Adjust. Factor Af
Adjust.
Factor
Ar
Weight Mult.
Double Angle Stitch Bolt Spacing
Diagonals in
Double Angle Stitch Bolt Spacing
Horizontals in
Double Angle Stitch Bolt Spacing
Redundants in
T1 152.00-140.00
0.00 0.0000 A36 (36 ksi)
1 1 1 36.0000 36.0000 36.0000
T2 140.00-120.00
0.00 0.0000 A36 (36 ksi)
1 1 1 36.0000 36.0000 36.0000
T3 120.00-100.00
0.00 0.0000 A36
1 1 1 36.0000 36.0000 36.0000
Meisnner
Page
FDH Infrastructure Services 6521 Meridien Drive
Project
PR-005358
Date
14:35:23 06/22/21 Raleigh, North Carolina 27616
Phone: (919) 755-1012
FAX: (919) 755-1031
Client Cushing Civil Engineers
Designed by
Deepak Devulapally
(per face)
Thickness
Gusset Grade Adjust. Factor Af
Adjust.
Factor
Ar
Weight Mult.
Double Angle Stitch Bolt Spacing
Diagonals in
Double Angle Stitch Bolt Spacing
Horizontals in
Double Angle Stitch Bolt Spacing
Redundants in
T4 100.00-80.00
0.00 0.0000 A36 (36 ksi)
1 1 1 36.0000 36.0000 36.0000
T5 80.00-60.00 0.00 0.0000 A36 (36 ksi)
1 1 1 36.0000 36.0000 36.0000
T6 60.00-40.00 0.00 0.0000 A36 (36 ksi)
1 1 1 36.0000 36.0000 36.0000
T7 40.00-20.00 0.00 0.0000 A36 (36 ksi)
1 1 1 36.0000 36.0000 36.0000
T8 20.00-0.00 0.00 0.0000 A36
1 1 1 36.0000 36.0000 36.0000
K Factors1
Calc K
Single Angles
Calc K
Solid Rounds
Legs X Brace Diags
X Y
K Brace Diags
X Y
Single Diags
Y
Girts
Horiz.
Sec.
Horiz.
Inner Brace
T1 152.00-140.00
Yes No 1 1
T2 140.00-120.00
Yes No 1 1
T3 120.00-100.00
Yes No 1 1
T4 100.00-80.00
Yes No 1 1
T5 80.00-60.00
Yes No 1 1
T6 60.00-40.00
Yes No 1 1
T7 40.00-20.00
Yes No 1 1
T8 20.00-0.00 Yes No 1 1
1Note: K factors are applied to member segment lengths. K-braces without inner supporting members will have the K factor in the out-of-plane direction applied to the overall length.
ft
Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal
Net Width Deduct
U
Net Width Deduct
Net
Deduct
Deduct
Deduct
Deduct
T1 152.00-140.00
0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T2 140.00-120.00
0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
Meisnner
Page
FDH Infrastructure Services 6521 Meridien Drive
Project
PR-005358
Date
14:35:23 06/22/21 Raleigh, North Carolina 27616
Phone: (919) 755-1012
FAX: (919) 755-1031
Client Cushing Civil Engineers
Designed by
Deepak Devulapally
Tower Elevation ft
Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal
Net Width Deduct
Deduct
Deduct
Deduct
Deduct
T3 120.00-100.00
0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T4 100.00-80.00
0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T5 80.00-60.00 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 T6 60.00-40.00 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 T7 40.00-20.00 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 T8 20.00-0.00 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 ft
Redundant Horizontal
Redundant Diagonal
Redundant Sub-Diagonal
Redundant Sub-Horizontal
Redundant Vertical Redundant Hip Redundant Hip Diagonal
Net Width Deduct
Deduct
Deduct
Deduct
Deduct
T1 152.00-140.00
0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T2 140.00-120.00
0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T3 120.00-100.00
0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T4 100.00-80.00
0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T5 80.00-60.00 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 T6 60.00-40.00 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 T7 40.00-20.00 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 T8 20.00-0.00 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 ft
Leg Connection
Type
Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal
Bolt Size in
No. Bolt Size in
No. Bolt Size in
No. Bolt Size in
No. Bolt Size in
No. Bolt Size in
No. Bolt Size in
No.
T1 152.00-140.00
Flange 0.6250 A325N
4 0.6250 A325N
1 0.6250 A325N
1 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
T2 140.00-120.00
Flange 0.6250 A325N
4 0.6250 A325N
1 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
T3 120.00-100.00
Flange 0.7500 A325N
4 0.6250 A325N
1 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
T4 100.00-80.00
Flange 0.8750 A325N
4 0.6250 A325N
1 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
T5 80.00-60.00 Flange 0.8750 A325N
4 0.6250 A325N
1 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
T6 60.00-40.00 Flange 1.0000 A325N
4 0.6250 A325N
1 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
T7 40.00-20.00 Flange 1.0000 A325N
6 0.6250 A325N
1 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
Meisnner
Page
FDH Infrastructure Services 6521 Meridien Drive
Project
PR-005358
Date
14:35:23 06/22/21 Raleigh, North Carolina 27616
Phone: (919) 755-1012
FAX: (919) 755-1031
Client Cushing Civil Engineers
Designed by
Deepak Devulapally
Tower Elevation ft
Leg Connection
Type
Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal
Bolt Size in
No. Bolt Size in
No. Bolt Size in
No. Bolt Size in
No. Bolt Size in
No. Bolt Size in
No. Bolt Size in
No.
T8 20.00-0.00 Flange 0.7500 A325N
0 0.7500 A325N
1 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
0 0.6250 A325N
Feed Line/Linear Appurtenances - Entered As Round Or Flat
Description Face or
Leg
Allow Shield
Exclude From
Torque Calculation
Component
Placement
Face Offset in
Lateral Offset
(Frac FW)
Per Row
Clear Spacing in
Width or Diameter
Perimeter
Weight plf
7/8'' C No No Ar (CaAa) 60.00 - 0.00 0.0000 0 2 2 0.5000 1.1100 0.54 7/8'' C No No Ar (CaAa) 149.00 -
60.00
0.0000 0 1 1 0.5000 1.1100 0.54
EW63(ELLIP
TICAL)
C No No Ar (CaAa) 80.00 - 0.00 0.0000 0.015 1 1 0.0000 2.0100 0.51
Feed Line/Linear Appurtenances Section Areas
Section
Tower Elevation
Face AR
AF
CAAA
In Face ft2
CAAA
Out Face
K T1 152.00-140.00 A
B C
0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000 0.999
0.000 0.000 0.000
0.00 0.00 0.00
T2 140.00-120.00 A B C
0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000 2.220
0.000 0.000 0.000
0.00 0.00 0.01
T3 120.00-100.00 A B C
0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000 2.220
0.000 0.000 0.000
0.00 0.00 0.01
T4 100.00-80.00 A B C
0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000 2.220
0.000 0.000 0.000
0.00 0.00 0.01
T5 80.00-60.00 A B C
0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000 6.240
0.000 0.000 0.000
0.00 0.00 0.02
T6 60.00-40.00 A B C
0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000 8.460
0.000 0.000 0.000
0.00 0.00 0.03
T7 40.00-20.00 A B C
0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000 8.460
0.000 0.000 0.000
0.00 0.00 0.03
T8 20.00-0.00 A B C
0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000 8.460
0.000 0.000 0.000
0.00 0.00 0.03
Feed Line/Linear Appurtenances Section Areas - With Ice
Meisnner
Page
FDH Infrastructure Services 6521 Meridien Drive
Project
PR-005358
Date
14:35:23 06/22/21 Raleigh, North Carolina 27616
Phone: (919) 755-1012
FAX: (919) 755-1031
Client Cushing Civil Engineers
Designed by
Deepak Devulapally
Tower Section
Tower Elevation ft
Face or
Leg
Ice Thickness
AR
In Face ft2
CAAA
Out Face
T1 152.00-140.00 A
B C
1.913 0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000 4.442
0.000 0.000 0.000
0.00 0.00 0.07
T2 140.00-120.00 A B C
1.899 0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000 9.815
0.000 0.000 0.000
0.00 0.00 0.15
T3 120.00-100.00 A B C
1.878 0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000 9.732
0.000 0.000 0.000
0.00 0.00 0.15
T4 100.00-80.00 A B C
1.851 0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000 9.625
0.000 0.000 0.000
0.00 0.00 0.14
T5 80.00-60.00 A B C
1.816 0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000
20.766
0.000 0.000 0.000
0.00 0.00 0.32
T6 60.00-40.00 A B C
1.766 0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000
30.552
0.000 0.000 0.000
0.00 0.00 0.37
T7 40.00-20.00 A B C
1.688 0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000
29.696
0.000 0.000 0.000
0.00 0.00 0.35
T8 20.00-0.00 A B C
1.522 0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000
27.868
0.000 0.000 0.000
0.00 0.00 0.31
Feed Line Center of Pressure
Section Elevation
CPX
CPZ
CPX
Ice in
CPZ
Ice in
T1 152.00-140.00 0.0000 0.4672 0.0000 0.7951 T2 140.00-120.00 0.0000 0.6120 0.0000 1.1268 T3 120.00-100.00 0.0000 0.6664 0.0000 1.3649 T4 100.00-80.00 0.0000 0.8058 0.0000 1.7542 T5 80.00-60.00 -0.0692 2.3491 -0.1065 4.0391 T6 60.00-40.00 -0.0708 2.6354 -0.1094 4.6875 T7 40.00-20.00 -0.0755 2.8143 -0.1158 4.9516 T8 20.00-0.00 -0.0831 3.0698 -0.1270 5.3965
Shielding Factor Ka
Feed Line Record No.
Description Feed Line Segment Elev.
Ka No Ice
Ka Ice
T1 2 7/8" 140.00 - 149.00
0.6000 0.4895
T2 2 7/8" 120.00 - 140.00
0.6000 0.5125
T3 2 7/8" 100.00 - 120.00
0.6000 0.5623
T4 2 7/8" 80.00 - 100.00 0.6000 0.6000 T5 2 7/8" 60.00 - 80.00 0.6000 0.6000
Meisnner
Page
FDH Infrastructure Services 6521 Meridien Drive
Project
PR-005358
Date
14:35:23 06/22/21 Raleigh, North Carolina 27616
Phone: (919) 755-1012
FAX: (919) 755-1031
Client Cushing Civil Engineers
Designed by
Deepak Devulapally
Tower Section
Feed Line Record No.
Description Feed Line Segment Elev.
Ka No Ice
Ka Ice
T5 3 EW63(ELLIPTICAL) 60.00 - 80.00 0.6000 0.6000
T6 1 7/8" 40.00 - 60.00 0.6000 0.6000
T6 3 EW63(ELLIPTICAL) 40.00 - 60.00 0.6000 0.6000
T7 1 7/8" 20.00 - 40.00 0.6000 0.6000
T7 3 EW63(ELLIPTICAL) 20.00 - 40.00 0.6000 0.6000
T8 1 7/8" 0.00 - 20.00 0.6000 0.6000
T8 3 EW63(ELLIPTICAL) 0.00 - 20.00 0.6000 0.6000
Discrete Tower Loads
Leg
Offset Type
Offsets:
Horz
Lateral Vert ft ft ft
Azimuth Adjustment
Placement
Front
Side
220-3BN B From Leg 3.00 0.00 10.00
0.0000 149.00 No Ice 1/2'' Ice 1'' Ice
4.78 7.83 9.96
4.78 7.83 9.96
0.02 0.07 0.12
Side Arm Mount [SO 305-1] B From Leg 1.50 0.00 0.00
0.0000 149.00 No Ice 1/2'' Ice 1'' Ice
0.53 0.78 1.06
1.52 2.07 2.66
0.03 0.04 0.06
DS8A03F36U-N A From Leg 3.00 0.00 1.50
0.0000 60.00 No Ice 1/2'' Ice 1'' Ice
0.50 0.68 0.87
0.50 0.68 0.87
0.01 0.01 0.02
Side Arm Mount [SO 305-1] A From Leg 1.50 0.00 0.00
0.0000 60.00 No Ice 1/2'' Ice 1'' Ice
0.53 0.78 1.06
1.52 2.07 2.66
0.03 0.04 0.06
Dishes
Leg
Dish Type
Offset Type
Offsets:
Horz
Lateral Vert ft
Adjustment
3 dB Beam
Outside Diameter
Aperture
EPMP FORCE 200
5GHZ
C Paraboloid w/o
Radome From Leg
0.50 0.00 0.00
0.0000 80.00 1.54 No Ice 1/2'' Ice 1'' Ice
1.87 2.07 2.28
0.01 0.02 0.03
Tower Pressures - No Ice
GH = 0.850
Meisnner
Page
FDH Infrastructure Services 6521 Meridien Drive
Project
PR-005358
Date
14:35:23 06/22/21 Raleigh, North Carolina 27616
Phone: (919) 755-1012
FAX: (919) 755-1031
Client Cushing Civil Engineers
Designed by
Deepak Devulapally z
KZ
qz psf
AG
a c
Aleg
In
Face ft2
CAAA
Out Face ft2 T1
152.00-140.00
146.00 1.371 106 57.844 A
B C
5.676 5.676 5.676
5.750 5.750 5.750
5.750 50.32 50.32 50.32
0.000 0.000 0.999
0.000 0.000 0.000
T2 140.00-120.00
130.00 1.337 104 96.406 A B C
9.606 9.606 9.606
9.583 9.583 9.583
9.583 49.94 49.94 49.94
0.000 0.000 2.220
0.000 0.000 0.000
T3 120.00-100.00
110.00 1.291 103 116.412 A B C
10.965 10.965 10.965
9.599 9.599 9.599
9.599 46.68 46.68 46.68
0.000 0.000 2.220
0.000 0.000 0.000
T4 100.00-80.00
90.00 1.238 100 157.559 A B C
11.656 11.656 11.656
11.686 11.686 11.686
11.686 50.07 50.07 50.07
0.000 0.000 2.220
0.000 0.000 0.000
T5 80.00-60.00 70.00 1.174 96 200.427 A B C
14.094 14.094 14.094
15.028 15.028 15.028
15.028 51.60 51.60 51.60
0.000 0.000 6.240
0.000 0.000 0.000
T6 60.00-40.00 50.00 1.094 91 244.493 A B C
16.237 16.237 16.237
18.578 18.578 18.578
18.578 53.36 53.36 53.36
0.000 0.000 8.460
0.000 0.000 0.000
T7 40.00-20.00 30.00 0.982 83 285.793 A B C
18.546 18.546 18.546
18.575 18.575 18.575
18.575 50.04 50.04 50.04
0.000 0.000 8.460
0.000 0.000 0.000
T8 20.00-0.00 10.00 0.85 73 328.557 A B C
18.114 18.114 18.114
22.123 22.123 22.123
22.123 54.98 54.98 54.98
0.000 0.000 8.460
0.000 0.000
Tower Pressure - With Ice tZ a c
Face ft2
CAAA
Out Face ft2 T1
152.00-140.00
146.00 1.371 6 1.9125 61.669 A
B C
5.676 5.676 5.676
25.806 25.806 25.806
13.400 42.56 42.56 42.56
0.000 0.000 4.442
0.000 0.000 0.000
T2 140.00-120.00
130.00 1.337 6 1.8989 102.736 A B C
9.606 9.606 9.606
40.482 40.482 40.482
22.242 44.41 44.41 44.41
0.000 0.000 9.815
0.000 0.000 0.000
T3 120.00-100.00
110.00 1.291 5 1.8779 122.680 A B C
10.965 10.965 10.965
42.731 42.731 42.731
22.140 41.23 41.23 41.23
0.000 0.000 9.732
0.000 0.000 0.000
T4 100.00-80.00 90.00 1.238 5 1.8512 163.738 A B C
11.656 11.656 11.656
45.625 45.625 45.625
24.048 41.98 41.98 41.98
0.000 0.000 9.625
0.000 0.000 0.000
T5 80.00-60.00 70.00 1.174 5 1.8158 206.488 A B C
14.094 14.094 14.094
47.628 47.628 47.628
27.155 44.00 44.00 44.00
0.000 0.000
20.766
0.000 0.000 0.000
T6 60.00-40.00 50.00 1.094 5 1.7661 250.388 A B C
16.237 16.237 16.237
53.315 53.315 53.315
30.374 43.67 43.67 43.67
0.000 0.000
30.552
0.000 0.000 0.000
T7 40.00-20.00 30.00 0.982 4 1.6882 291.428 A B C
18.546 18.546 18.546
54.896 54.896 54.896
29.848 40.64 40.64 40.64
0.000 0.000
29.696
0.000 0.000 0.000
T8 20.00-0.00 10.00 0.85 4 1.5218 333.636 A B
18.114 18.114
50.664 50.664
32.287 46.94 46.94
0.000 0.000
Meisnner
Page
FDH Infrastructure Services 6521 Meridien Drive
Project
PR-005358
Date
14:35:23 06/22/21 Raleigh, North Carolina 27616
Phone: (919) 755-1012
FAX: (919) 755-1031
Client Cushing Civil Engineers
Designed by
Deepak Devulapally tZ a c
Face ft2
CAAA
Out Face
C 18.114 50.664 46.94 27.868 0.000
Tower Pressure - Service a c
Face ft2
CAAA
Out Face ft2 T1
152.00-140.00
146.00 1.371 23 57.844 A
B C
5.676 5.676 5.676
5.750 5.750 5.750
5.750 50.32 50.32 50.32
0.000 0.000 0.999
0.000 0.000 0.000
T2 140.00-120.00
130.00 1.337 22 96.406 A B C
9.606 9.606 9.606
9.583 9.583 9.583
9.583 49.94 49.94 49.94
0.000 0.000 2.220
0.000 0.000 0.000
T3 120.00-100.00
110.00 1.291 22 116.412 A B C
10.965 10.965 10.965
9.599 9.599 9.599
9.599 46.68 46.68 46.68
0.000 0.000 2.220
0.000 0.000 0.000
T4 100.00-80.00
90.00 1.238 21 157.559 A B C
11.656 11.656 11.656
11.686 11.686 11.686
11.686 50.07 50.07 50.07
0.000 0.000 2.220
0.000 0.000 0.000
T5 80.00-60.00 70.00 1.174 21 200.427 A B C
14.094 14.094 14.094
15.028 15.028 15.028
15.028 51.60 51.60 51.60
0.000 0.000 6.240
0.000 0.000 0.000
T6 60.00-40.00 50.00 1.094 19 244.493 A B C
16.237 16.237 16.237
18.578 18.578 18.578
18.578 53.36 53.36 53.36
0.000 0.000 8.460
0.000 0.000 0.000
T7 40.00-20.00 30.00 0.982 18 285.793 A B C
18.546 18.546 18.546
18.575 18.575 18.575
18.575 50.04 50.04 50.04
0.000 0.000 8.460
0.000 0.000 0.000
T8 20.00-0.00 10.00 0.85 16 328.557 A B C
18.114 18.114 18.114
22.123 22.123 22.123
22.123 54.98 54.98 54.98
0.000 0.000 8.460
0.000
Tower Forces - No Ice - Wind Normal To Face
Add
Self a c e CF
DF
DR
AE
w
Ctrl.
Face
T1 152.00-140.00
0.00 0.47 A B C
0.198 0.198 0.198
2.604 2.604 2.604
106 1
8.713 8.713 8.713
2.09 174.40 C
T2 140.00-120.00
0.01 0.93 A B C
0.199 0.199 0.199
2.599 2.599 2.599
104 1
14.681 14.681 14.681
3.51 175.36 C
T3 120.00-100.00
0.01 1.12 A B C
0.177 0.177 0.177
2.676 2.676 2.676
103 1
16.002 16.002 16.002
3.85 192.34 C
T4 100.00-80.00
0.01 1.31 A B
0.148 0.148
2.778 2.778
100 1
17.233 17.233
4.18 208.90 C
Meisnner
Page
FDH Infrastructure Services 6521 Meridien Drive
Project
PR-005358
Date
14:35:23 06/22/21 Raleigh, North Carolina 27616
Phone: (919) 755-1012
FAX: (919) 755-1031
Client Cushing Civil Engineers
Designed by
Deepak Devulapally a c
Face
C 0.148 2.778 1 1 17.233 T5
80.00-60.00
0.02 1.55 A
B C
0.145 0.145 0.145
2.789 2.789 2.789
96 1
20.350 20.350 20.350
4.95 247.66 C
T6 60.00-40.00
0.03 2.00 A B C
0.142 0.142 0.142
2.8 2.8 2.8
91 1
23.945 23.945 23.945
5.59 279.69 C
T7 40.00-20.00
0.03 2.37 A B C
0.13 0.13 0.13
2.847 2.847 2.847
83 1
26.139 26.139 26.139
5.63 281.65 C
T8 20.00-0.00 0.03 2.48 A B C
0.122 0.122 0.122
2.875 2.875 2.875
73 1
27.079 27.079 27.079
5.18 258.76 C
Sum Weight: 0.15 12.22 OTM 2407.82 kip-ft
34.98
Tower Forces - No Ice - Wind 60 To Face a c
Face
T1 152.00-140.00
0.00 0.47 A B C
0.198 0.198 0.198
2.604 2.604 2.604
106 0.8 0.8 0.8
7.578 7.578 7.578
1.83 152.26 C
T2 140.00-120.00
0.01 0.93 A B C
0.199 0.199 0.199
2.599 2.599 2.599
104 0.8 0.8 0.8
12.760 12.760 12.760
3.06 153.19 C
T3 120.00-100.00
0.01 1.12 A B C
0.177 0.177 0.177
2.676 2.676 2.676
103 0.8 0.8 0.8
13.809 13.809 13.809
3.34 166.78 C
T4 100.00-80.00
0.01 1.31 A B C
0.148 0.148 0.148
2.778 2.778 2.778
100 0.8 0.8 0.8
14.902 14.902 14.902
3.63 181.41 C
T5 80.00-60.00
0.02 1.55 A B C
0.145 0.145 0.145
2.789 2.789 2.789
96 0.8 0.8 0.8
17.532 17.532 17.532
4.31 215.48 C
T6 60.00-40.00
0.03 2.00 A B C
0.142 0.142 0.142
2.8 2.8 2.8
91 0.8 0.8 0.8
20.697 20.697 20.697
4.89 244.43 A
T7 40.00-20.00
0.03 2.37 A B C
0.13 0.13 0.13
2.847 2.847 2.847
83 0.8 0.8 0.8
22.430 22.430 22.430
4.88 244.23 A
T8 20.00-0.00 0.03 2.48 A B C
0.122 0.122 0.122
2.875 2.875 2.875
73 0.8 0.8 0.8
23.456 23.456 23.456
4.53 226.26 A
Sum Weight: 0.15 12.22 OTM 2096.39
30.46
Meisnner
Page
FDH Infrastructure Services 6521 Meridien Drive
Project
PR-005358
Date
14:35:23 06/22/21 Raleigh, North Carolina 27616
Phone: (919) 755-1012
FAX: (919) 755-1031
Client Cushing Civil Engineers
Designed by
Deepak
Tower Forces - No Ice - Wind 90 To Face a c
Face
T1 152.00-140.00
0.00 0.47 A B C
0.198 0.198 0.198
2.604 2.604 2.604
106 0.85 0.85 0.85
7.861 7.861 7.861
1.89 157.80 C
T2 140.00-120.00
0.01 0.93 A B C
0.199 0.199 0.199
2.599 2.599 2.599
104 0.85 0.85 0.85
13.240 13.240 13.240
3.17 158.73 C
T3 120.00-100.00
0.01 1.12 A B C
0.177 0.177 0.177
2.676 2.676 2.676
103 0.85 0.85 0.85
14.358 14.358 14.358
3.46 173.17 C
T4 100.00-80.00
0.01 1.31 A B C
0.148 0.148 0.148
2.778 2.778 2.778
100 0.85 0.85 0.85
15.485 15.485 15.485
3.77 188.28 C
T5 80.00-60.00
0.02 1.55 A B C
0.145 0.145 0.145
2.789 2.789 2.789
96 0.85 0.85 0.85
18.236 18.236 18.236
4.47 223.52 C
T6 60.00-40.00
0.03 2.00 A B C
0.142 0.142 0.142
2.8 2.8 2.8
91 0.85 0.85 0.85
21.509 21.509 21.509
5.06 253.24 B
T7 40.00-20.00
0.03 2.37 A B C
0.13 0.13 0.13
2.847 2.847 2.847
83 0.85 0.85 0.85
23.357 23.357 23.357
5.07 253.59 B
T8 20.00-0.00 0.03 2.48 A B C
0.122 0.122 0.122
2.875 2.875 2.875
73 0.85 0.85 0.85
24.362 24.362 24.362
4.69 234.38 B
Sum Weight: 0.15 12.22 OTM 2174.25
31.59
Tower Forces - With Ice - Wind Normal To Face a c
Face
T1 152.00-140.00
0.07 2.13 A B C
0.511 0.511 0.511
1.887 1.887 1.887
6 1
23.501 23.501 23.501
0.22 18.55 C
T2 140.00-120.00
0.15 3.60 A B C
0.488 0.488 0.488
1.917 1.917 1.917
6 1
37.066 37.066 37.066
0.36 17.99 C
T3 120.00-100.00
0.15 4.00 A B C
0.438 0.438 0.438
1.994 1.994 1.994
5 1
38.884 38.884 38.884
0.39 19.26 C
T4 100.00-80.00
0.14 4.35 A B C
0.35 0.35 0.35
2.172 2.172 2.172
5 1
39.761 39.761 39.761
0.42 20.83 C
T5 80.00-60.00
0.32 4.90 A B C
0.299 0.299 0.299
2.299 2.299 2.299
5 1
42.604 42.604 42.604
0.48 24.07 C
T6 60.00-40.00
0.37 5.73 A B C
0.278 0.278 0.278
2.357 2.357 2.357
5 1
47.817 47.817 47.817
0.53 26.59 C
Meisnner
Page
FDH Infrastructure Services 6521 Meridien Drive
Project
PR-005358
Date
14:35:23 06/22/21 Raleigh, North Carolina 27616
Phone: (919) 755-1012
FAX: (919) 755-1031
Client Cushing Civil Engineers
Designed by
Deepak Devulapally a c
Face
T7 40.00-20.00
0.35 6.25 A B C
0.252 0.252 0.252
2.431 2.431 2.431
4 1
50.688 50.688 50.688
0.52 26.20 C
T8 20.00-0.00 0.31 5.80 A B C
0.206 0.206 0.206
2.576 2.576 2.576
4 1
47.275 47.275 47.275
0.45 22.67 C
Sum Weight: 1.86 36.76 OTM 239.67
3.37
Tower Forces - With Ice - Wind 60 To Face a c
Face
T1 152.00-140.00
0.07 2.13 A B C
0.511 0.511 0.511
1.887 1.887 1.887
6 0.8 0.8 0.8
22.366 22.366 22.366
0.21 17.70 C
T2 140.00-120.00
0.15 3.60 A B C
0.488 0.488 0.488
1.917 1.917 1.917
6 0.8 0.8 0.8
35.145 35.145 35.145
0.34 17.12 C
T3 120.00-100.00
0.15 4.00 A B C
0.438 0.438 0.438
1.994 1.994 1.994
5 0.8 0.8 0.8
36.691 36.691 36.691
0.36 18.24 C
T4 100.00-80.00
0.14 4.35 A B C
0.35 0.35 0.35
2.172 2.172 2.172
5 0.8 0.8 0.8
37.430 37.430 37.430
0.39 19.68 C
T5 80.00-60.00
0.32 4.90 A B C
0.299 0.299 0.299
2.299 2.299 2.299
5 0.8 0.8 0.8
39.785 39.785 39.785
0.45 22.65 C
T6 60.00-40.00
0.37 5.73 A B C
0.278 0.278 0.278
2.357 2.357 2.357
5 0.8 0.8 0.8
44.569 44.569 44.569
0.50 25.01 A
T7 40.00-20.00
0.35 6.25 A B C
0.252 0.252 0.252
2.431 2.431 2.431
4 0.8 0.8 0.8
46.979 46.979 46.979
0.49 24.50 A
T8 20.00-0.00 0.31 5.80 A B C
0.206 0.206 0.206
2.576 2.576 2.576
4 0.8 0.8 0.8
43.653 43.653 43.653
0.42 21.12 A
Sum Weight: 1.86 36.76 OTM 226.73
3.18
Tower Forces - With Ice - Wind 90 To Face a c
Face
T1 0.07 2.13 A 0.511 1.887 6 0.85 1 22.650 0.21 17.91 C
Meisnner
Page
FDH Infrastructure Services 6521 Meridien Drive
Project
PR-005358
Date
14:35:23 06/22/21 Raleigh, North Carolina 27616
Phone: (919) 755-1012
FAX: (919) 755-1031
Client Cushing Civil Engineers
Designed by
Deepak Devulapally a c
Face
152.00-140.00 B C
0.511 0.511
1.887 1.887
0.85 0.85
22.650 22.650
T2 140.00-120.00
0.15 3.60 A B C
0.488 0.488 0.488
1.917 1.917 1.917
6 0.85 0.85 0.85
35.626 35.626 35.626
0.35 17.34 C
T3 120.00-100.00
0.15 4.00 A B C
0.438 0.438 0.438
1.994 1.994 1.994
5 0.85 0.85 0.85
37.239 37.239 37.239
0.37 18.50 C
T4 100.00-80.00
0.14 4.35 A B C
0.35 0.35 0.35
2.172 2.172 2.172
5 0.85 0.85 0.85
38.013 38.013 38.013
0.40 19.97 C
T5 80.00-60.00
0.32 4.90 A B C
0.299 0.299 0.299
2.299 2.299 2.299
5 0.85 0.85 0.85
40.490 40.490 40.490
0.46 23.01 C
T6 60.00-40.00
0.37 5.73 A B C
0.278 0.278 0.278
2.357 2.357 2.357
5 0.85 0.85 0.85
45.381 45.381 45.381
0.51 25.28 B
T7 40.00-20.00
0.35 6.25 A B C
0.252 0.252 0.252
2.431 2.431 2.431
4 0.85 0.85 0.85
47.906 47.906 47.906
0.50 24.81 B
T8 20.00-0.00 0.31 5.80 A B C
0.206 0.206 0.206
2.576 2.576 2.576
4 0.85 0.85 0.85
44.558 44.558 44.558
0.43 21.41 B
Sum Weight: 1.86 36.76 OTM 229.75
3.22
Tower Forces - Service - Wind Normal To Face a c
Face
T1 152.00-140.00
0.00 0.47 A B C
0.198 0.198 0.198
2.604 2.604 2.604
23 1
8.977 8.977 8.977
0.46 38.25 C
T2 140.00-120.00
0.01 0.93 A B C
0.199 0.199 0.199
2.599 2.599 2.599
22 1
15.109 15.109 15.109
0.77 38.41 C
T3 120.00-100.00
0.01 1.12 A B C
0.177 0.177 0.177
2.676 2.676 2.676
22 1
16.444 16.444 16.444
0.84 42.07 C
T4 100.00-80.00
0.01 1.31 A B C
0.148 0.148 0.148
2.778 2.778 2.778
21 1
18.286 18.286 18.286
0.94 47.15 C
T5 80.00-60.00
0.02 1.55 A B C
0.145 0.145 0.145
2.789 2.789 2.789
21 1
22.616 22.616 22.616
1.17 58.27 C
T6 60.00-40.00
0.03 2.00 A B C
0.142 0.142 0.142
2.8 2.8 2.8
19 1
26.419 26.419 26.419
1.31 65.30 C
T7 40.00-20.00
0.03 2.37 A B C
0.13 0.13 0.13
2.847 2.847 2.847
18 1
28.840 28.840 28.840
1.32 65.80 C
T8 20.00-0.00 0.03 2.48 A 0.122 2.875 16 1 1 29.912 1.21 60.53 C
Meisnner
Page
FDH Infrastructure Services 6521 Meridien Drive
Project
PR-005358
Date
14:35:23 06/22/21 Raleigh, North Carolina 27616
Phone: (919) 755-1012
FAX: (919) 755-1031
Client Cushing Civil Engineers
Designed by
Deepak Devulapally a c
Face
B C
0.122 0.122
2.875 2.875
29.912 29.912
Sum Weight: 0.15 12.22 OTM 542.74
8.01
Tower Forces - Service - Wind 60 To Face a c
Face
T1 152.00-140.00
0.00 0.47 A B C
0.198 0.198 0.198
2.604 2.604 2.604
23 0.8 0.8 0.8
7.842 7.842 7.842
0.40 33.53 C
T2 140.00-120.00
0.01 0.93 A B C
0.199 0.199 0.199
2.599 2.599 2.599
22 0.8 0.8 0.8
13.188 13.188 13.188
0.67 33.68 C
T3 120.00-100.00
0.01 1.12 A B C
0.177 0.177 0.177
2.676 2.676 2.676
22 0.8 0.8 0.8
14.251 14.251 14.251
0.73 36.62 C
T4 100.00-80.00
0.01 1.31 A B C
0.148 0.148 0.148
2.778 2.778 2.778
21 0.8 0.8 0.8
15.955 15.955 15.955
0.83 41.29 C
T5 80.00-60.00
0.02 1.55 A B C
0.145 0.145 0.145
2.789 2.789 2.789
21 0.8 0.8 0.8
19.797 19.797 19.797
1.03 51.41 C
T6 60.00-40.00
0.03 2.00 A B C
0.142 0.142 0.142
2.8 2.8 2.8
19 0.8 0.8 0.8
23.171 23.171 23.171
1.16 57.79 A
T7 40.00-20.00
0.03 2.37 A B C
0.13 0.13 0.13
2.847 2.847 2.847
18 0.8 0.8 0.8
25.131 25.131 25.131
1.16 57.83 A
T8 20.00-0.00 0.03 2.48 A B C
0.122 0.122 0.122
2.875 2.875 2.875
16 0.8 0.8 0.8
26.289 26.289 26.289
1.07 53.61 A
Sum Weight: 0.15 12.22 OTM 476.40
7.05
Tower Forces - Service - Wind 90 To Face a c
Face
T1 152.00-140.00
0.00 0.47 A B C
0.198 0.198 0.198
2.604 2.604 2.604
23 0.85 0.85 0.85
8.125 8.125 8.125
0.42 34.71 C
T2 140.00-120.00
0.01 0.93 A B
0.199 0.199
2.599 2.599
22 0.85 0.85
13.669 13.669
0.70 34.87 C
Meisnner
Page
FDH Infrastructure Services 6521 Meridien Drive
Project
PR-005358
Date
14:35:23 06/22/21 Raleigh, North Carolina 27616
Phone: (919) 755-1012
FAX: (919) 755-1031
Client Cushing Civil Engineers
Designed by
Deepak Devulapally a c
Face
C 0.199 2.599 0.85 1 13.669 T3
120.00-100.00
0.01 1.12 A
B C
0.177 0.177 0.177
2.676 2.676 2.676
22 0.85 0.85 0.85
14.799 14.799 14.799
0.76 37.99 C
T4 100.00-80.00
0.01 1.31 A B C
0.148 0.148 0.148
2.778 2.778 2.778
21 0.85 0.85 0.85
16.538 16.538 16.538
0.86 42.75 C
T5 80.00-60.00
0.02 1.55 A B C
0.145 0.145 0.145
2.789 2.789 2.789
21 0.85 0.85 0.85
20.502 20.502 20.502
1.06 53.12 C
T6 60.00-40.00
0.03 2.00 A B C
0.142 0.142 0.142
2.8 2.8 2.8
19 0.85 0.85 0.85
23.983 23.983 23.983
1.19 59.67 B
T7 40.00-20.00
0.03 2.37 A B C
0.13 0.13 0.13
2.847 2.847 2.847
18 0.85 0.85 0.85
26.058 26.058 26.058
1.20 59.82 B
T8 20.00-0.00 0.03 2.48 A B C
0.122 0.122 0.122
2.875 2.875 2.875
16 0.85 0.85 0.85
27.195 27.195 27.195
1.11 55.34 B
Sum Weight: 0.15 12.22 OTM 492.99
7.29
Discrete Appurtenance Pressures - No Ice GH = 0.850
Description Aiming
Offsetx
Offsetz
Kz qz
CAAC
Front ft2
CAAC
Side ft2
220-3BN 120.0000 0.02 4.89 2.82 159.00 1.395 107 4.78 4.78
Side Arm Mount [SO 305-1]
120.0000 0.03 3.59 2.07 149.00 1.376 106 0.53 1.52
DS8A03F36U-N 0.0000 0.01 0.00 -9.18 61.50 1.142 94 0.50 0.50
Side Arm Mount [SO 305-1]
0.0000 0.03 0.00 -7.68 60.00 1.137 94 0.53 1.52
Sum Weight:
0.09
Discrete Appurtenance Pressures - With Ice GH = 0.850
Front ft2
CAAC
Side tz
220-3BN 120.0000 0.26 4.89 2.82 159.00 1.395 6 13.96 13.96 1.9289
Side Arm Mount [SO 305-1]
120.0000 0.12 3.59 2.07 149.00 1.376 6 1.67 3.81 1.9164
DS8A03F36U-N 0.0000 0.03 0.00 -9.18 61.50 1.142 5 1.19 1.19 1.7924
Side Arm Mount [SO 305-1]
0.0000 0.11 0.00 -7.68 60.00 1.137 5 1.60 3.66 1.7986
Sum
0.53
Meisnner
Page
FDH Infrastructure Services 6521 Meridien Drive
Project
PR-005358
Date
14:35:23 06/22/21 Raleigh, North Carolina 27616
Phone: (919) 755-1012
FAX: (919) 755-1031
Client Cushing Civil Engineers
Designed by
Deepak
Discrete Appurtenance Pressures - Service GH = 0.850
Front ft2
CAAC
Side ft2
220-3BN 120.0000 0.02 4.89 2.82 159.00 1.395 23 4.78 4.78
Side Arm Mount [SO 305-1]
120.0000 0.03 3.59 2.07 149.00 1.376 23 0.53 1.52
DS8A03F36U-N 0.0000 0.01 0.00 -9.18 61.50 1.142 20 0.50 0.50
Side Arm Mount [SO 305-1]
0.0000 0.03 0.00 -7.68 60.00 1.137 20 0.53 1.52
Sum
0.09
Dish Pressures - No Ice
Dish Description
Aiming Azimuth
Weight K
Offsetx ft
Offsetz
Kz
AA
qz psf
80.00 EPMP FORCE 200 5GHZ 240.0000 0.01 -4.73 2.73 1.208 1.87 98
Sum
0.01
Dish Pressures - With Ice
Dish Description
Aiming Azimuth
Weight K
Offsetx ft
Offsetz qz psf tz in
80.00 EPMP FORCE 200 5GHZ 240.0000 0.04 -4.73 2.73 1.208 2.48 5 1.4721
Sum
0.04
Dish Pressures - Service
Dish Description
Aiming Azimuth
Weight K
Offsetx ft
Offsetz qz psf
80.00 EPMP FORCE 200 5GHZ 240.0000 0.01 -4.73 2.73 1.208 1.87 21
Sum
0.01
Force Totals
Load Case
Vertical Forces
Sum of Forces
X K
Sum of Forces
Z K
Sum of Overturning Moments, Mx kip-ft
Sum of Overturning Moments, Mz
Sum of Torques
Leg Weight 6.41 Bracing Weight 5.82 Total Member Self-Weight 12.22 0.36 -0.17 Total Weight 12.47 0.36 -0.17 Wind 0 deg - No Ice 0.24 -35.77 -2511.27 -22.25 2.29
Meisnner
Page
FDH Infrastructure Services 6521 Meridien Drive
Project
PR-005358
Date
14:35:23 06/22/21 Raleigh, North Carolina 27616
Phone: (919) 755-1012
FAX: (919) 755-1031
Client Cushing Civil Engineers
Designed by
Deepak Devulapally
Load Case
Forces
Sum of Forces
X K
Sum of Forces
Z K
Sum of Overturning Moments, Mx kip-ft
Sum of Overturning Moments, Mz
Sum of Torques
Wind 30 deg - No Ice 16.37 -28.04 -1973.56 -1153.79 5.21 Wind 60 deg - No Ice 27.11 -15.66 -1106.64 -1910.16 6.19 Wind 90 deg - No Ice 32.25 -0.16 -15.44 -2273.43 5.18 Wind 120 deg - No Ice 31.02 17.63 1235.75 -2176.69 3.90 Wind 150 deg - No Ice 16.12 27.93 1962.95 -1128.84 1.21 Wind 180 deg - No Ice -0.06 31.19 2195.45 7.67 -2.05 Wind 210 deg - No Ice -16.24 28.04 1973.97 1142.36 -4.81 Wind 240 deg - No Ice -30.96 17.88 1259.98 2174.16 -6.19 Wind 270 deg - No Ice -32.18 0.05 6.72 2267.26 -5.57 Wind 300 deg - No Ice -26.96 -15.50 -1089.08 1895.09 -4.14 Wind 330 deg - No Ice -16.12 -27.93 -1962.08 1128.75 -1.21 Member Ice 24.53 Total Weight Ice 39.18 5.81 -1.39 Wind 0 deg - Ice 0.02 -3.48 -248.53 -3.20 0.36 Wind 30 deg - Ice 1.68 -2.88 -206.07 -124.80 0.84 Wind 60 deg - Ice 2.84 -1.64 -115.37 -210.42 1.03 Wind 90 deg - Ice 3.31 -0.01 4.44 -245.20 0.95 Wind 120 deg - Ice 3.01 1.71 131.09 -221.15 0.67 Wind 150 deg - Ice 1.66 2.87 216.64 -122.60 0.21 Wind 180 deg - Ice -0.01 3.28 246.85 -0.58 -0.35 Wind 210 deg - Ice -1.67 2.88 217.67 121.24 -0.82 Wind 240 deg - Ice -3.00 1.73 133.24 218.47 -1.03 Wind 270 deg - Ice -3.31 0.00 6.51 242.01 -0.98 Wind 300 deg - Ice -2.83 -1.62 -113.69 206.35 -0.69 Wind 330 deg - Ice -1.66 -2.87 -205.01 119.84 -0.21 Total Weight 12.47 0.36 -0.17 Wind 0 deg - Service 0.05 -8.18 -565.01 -4.88 0.49 Wind 30 deg - Service 3.77 -6.46 -446.47 -260.84 1.11 Wind 60 deg - Service 6.26 -3.61 -250.88 -432.88 1.32 Wind 90 deg - Service 7.43 -0.03 -3.51 -514.26 1.10 Wind 120 deg - Service 7.09 4.04 277.93 -489.66 0.83 Wind 150 deg - Service 3.71 6.43 443.76 -255.52 0.26 Wind 180 deg - Service -0.01 7.20 497.28 1.49 -0.44 Wind 210 deg - Service -3.74 6.46 446.10 258.12 -1.02 Wind 240 deg - Service -7.08 4.09 283.09 488.83 -1.32 Wind 270 deg - Service -7.41 0.01 1.21 512.66 -1.19 Wind 300 deg - Service -6.23 -3.58 -247.14 429.38 -0.88 Wind 330 deg - Service -3.71 -6.43 -444.02 255.22 -0.26
Load Combinations
Comb.
No.
Description
1 Dead Only 2 1.2 Dead+1.0 Wind 0 deg - No Ice 3 0.9 Dead+1.0 Wind 0 deg - No Ice 4 1.2 Dead+1.0 Wind 30 deg - No Ice 5 0.9 Dead+1.0 Wind 30 deg - No Ice 6 1.2 Dead+1.0 Wind 60 deg - No Ice 7 0.9 Dead+1.0 Wind 60 deg - No Ice 8 1.2 Dead+1.0 Wind 90 deg - No Ice 9 0.9 Dead+1.0 Wind 90 deg - No Ice 10 1.2 Dead+1.0 Wind 120 deg - No Ice 11 0.9 Dead+1.0 Wind 120 deg - No Ice 12 1.2 Dead+1.0 Wind 150 deg - No Ice 13 0.9 Dead+1.0 Wind 150 deg - No Ice
Meisnner
Page
FDH Infrastructure Services 6521 Meridien Drive
Project
PR-005358
Date
14:35:23 06/22/21 Raleigh, North Carolina 27616
Phone: (919) 755-1012
FAX: (919) 755-1031
Client Cushing Civil Engineers
Designed by
Deepak Devulapally
Comb.
No.
Description
14 1.2 Dead+1.0 Wind 180 deg - No Ice 15 0.9 Dead+1.0 Wind 180 deg - No Ice 16 1.2 Dead+1.0 Wind 210 deg - No Ice 17 0.9 Dead+1.0 Wind 210 deg - No Ice 18 1.2 Dead+1.0 Wind 240 deg - No Ice 19 0.9 Dead+1.0 Wind 240 deg - No Ice 20 1.2 Dead+1.0 Wind 270 deg - No Ice 21 0.9 Dead+1.0 Wind 270 deg - No Ice 22 1.2 Dead+1.0 Wind 300 deg - No Ice 23 0.9 Dead+1.0 Wind 300 deg - No Ice 24 1.2 Dead+1.0 Wind 330 deg - No Ice 25 0.9 Dead+1.0 Wind 330 deg - No Ice 26 1.2 Dead+1.0 Ice+1.0 Temp 27 1.2 Dead+1.0 Wind 0 deg+1.0 Ice+1.0 Temp 28 1.2 Dead+1.0 Wind 30 deg+1.0 Ice+1.0 Temp 29 1.2 Dead+1.0 Wind 60 deg+1.0 Ice+1.0 Temp 30 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp 31 1.2 Dead+1.0 Wind 120 deg+1.0 Ice+1.0 Temp 32 1.2 Dead+1.0 Wind 150 deg+1.0 Ice+1.0 Temp 33 1.2 Dead+1.0 Wind 180 deg+1.0 Ice+1.0 Temp 34 1.2 Dead+1.0 Wind 210 deg+1.0 Ice+1.0 Temp 35 1.2 Dead+1.0 Wind 240 deg+1.0 Ice+1.0 Temp 36 1.2 Dead+1.0 Wind 270 deg+1.0 Ice+1.0 Temp 37 1.2 Dead+1.0 Wind 300 deg+1.0 Ice+1.0 Temp 38 1.2 Dead+1.0 Wind 330 deg+1.0 Ice+1.0 Temp 39 Dead+Wind 0 deg - Service 40 Dead+Wind 30 deg - Service 41 Dead+Wind 60 deg - Service 42 Dead+Wind 90 deg - Service 43 Dead+Wind 120 deg - Service 44 Dead+Wind 150 deg - Service 45 Dead+Wind 180 deg - Service 46 Dead+Wind 210 deg - Service 47 Dead+Wind 240 deg - Service 48 Dead+Wind 270 deg - Service 49 Dead+Wind 300 deg - Service 50 Dead+Wind 330 deg - Service
Maximum Member Forces
No.
Elevation ft Component
Type Condition Gov.
Load
Axial
Major Axis Moment kip-ft
Minor Axis Moment kip-ft T1 152 - 140 Leg Max Tension 15 3.94 0.03 -0.01
Max. Compression 18 -4.46 0.06 -0.02 Max. Mx 18 -1.24 -0.18 0.03 Max. My 16 -0.14 0.11 0.26 Max. Vy 19 -0.34 0.15 0.03 Max. Vx 4 -0.46 -0.11 0.19 Diagonal Max Tension 18 1.30 0.00 0.00 Max. Compression 18 -1.31 0.00 0.00 Max. Mx 31 0.13 0.01 0.00 Max. My 16 -0.79 0.00 0.00 Max. Vy 31 -0.02 0.01 0.00 Max. Vx 16 0.00 0.00 0.00 Top Girt Max Tension 15 0.03 0.00 0.00 Max. Compression 18 -0.04 0.00 0.00 Max. Mx 26 -0.03 -0.03 0.00 Max. My 4 -0.01 0.00 0.00
Meisnner
Page
FDH Infrastructure Services 6521 Meridien Drive
Project
PR-005358
Date
14:35:23 06/22/21 Raleigh, North Carolina 27616
Phone: (919) 755-1012
FAX: (919) 755-1031
Client Cushing Civil Engineers
Designed by
Deepak Devulapally
Section No.
Elevation ft
Component Type
Condition Gov.
Load
Moment kip-ft
Minor Axis Moment kip-ft Max. Vy 26 0.03 0.00 0.00 Max. Vx 4 -0.00 0.00 0.00
T2 140 - 120 Leg Max Tension 15 21.62 0.00 -0.06 Max. Compression 18 -24.94 0.13 -0.06 Max. Mx 8 -0.66 -0.13 -0.00 Max. My 2 -24.93 0.01 0.14 Max. Vy 8 0.08 -0.13 -0.00 Max. Vx 2 -0.08 0.03 0.13 Diagonal Max Tension 8 2.61 0.00 0.00 Max. Compression 18 -2.93 0.00 0.00 Max. Mx 18 2.47 0.04 -0.00 Max. My 16 -1.86 -0.02 0.01 Max. Vy 31 -0.02 0.02 0.00 Max. Vx 16 -0.00 -0.02 0.01
T3 120 - 100 Leg Max Tension 15 39.81 -0.10 -0.00 Max. Compression 18 -46.58 0.13 0.00 Max. Mx 18 -29.95 0.14 0.01 Max. My 16 -1.06 -0.00 0.14 Max. Vy 2 0.07 0.14 -0.01 Max. Vx 12 0.08 -0.00 -0.14 Diagonal Max Tension 20 2.21 0.00 0.00 Max. Compression 18 -2.32 0.00 0.00 Max. Mx 2 1.27 0.03 -0.00 Max. My 18 -2.13 -0.02 0.01 Max. Vy 33 0.03 0.02 0.00 Max. Vx 6 0.00 0.00 0.00
T4 100 - 80 Leg Max Tension 15 57.50 -0.16 -0.00 Max. Compression 18 -67.84 0.24 0.00 Max. Mx 3 -67.39 0.24 -0.01 Max. My 12 -1.85 -0.00 -0.23 Max. Vy 3 -0.10 0.19 0.00 Max. Vx 24 -0.09 -0.01 0.23 Diagonal Max Tension 8 2.94 0.00 0.00 Max. Compression 18 -2.99 0.00 0.00 Max. Mx 33 0.15 0.04 0.01 Max. My 34 -0.12 0.03 0.01 Max. Vy 33 0.04 0.04 0.01 Max. Vx 34 0.00 0.00 0.00
T5 80 - 60 Leg Max Tension 7 75.91 -0.29 -0.01 Max. Compression 18 -89.94 0.39 0.01 Max. Mx 3 -89.31 0.39 0.01 Max. My 4 -2.41 -0.00 -0.36 Max. Vy 6 -0.18 -0.22 -0.00 Max. Vx 4 -0.18 -0.00 -0.22 Diagonal Max Tension 8 3.95 0.00 0.00 Max. Compression 18 -4.06 0.00 0.00 Max. Mx 33 0.27 0.07 -0.01 Max. My 35 -0.09 0.06 0.01 Max. Vy 33 0.05 0.07 -0.01 Max. Vx 35 0.00 0.00 0.00
T6 60 - 40 Leg Max Tension 7 96.97 -0.40 -0.00 Max. Compression 18 -115.41 0.60 0.02 Max. Mx 19 -114.60 0.60 0.02 Max. My 4 -3.47 -0.00 -0.57 Max. Vy 11 0.18 0.39 -0.02 Max. Vx 8 0.24 -0.00 0.32 Diagonal Max Tension 20 4.84 0.00 0.00 Max. Compression 20 -4.91 0.00 0.00 Max. Mx 33 0.12 0.09 0.01 Max. My 35 -0.29 0.09 0.01 Max. Vy 33 0.06 0.09 0.01
Meisnner
Page
FDH Infrastructure Services 6521 Meridien Drive
Project
PR-005358
Date
14:35:23 06/22/21 Raleigh, North Carolina 27616
Phone: (919) 755-1012
FAX: (919) 755-1031
Client Cushing Civil Engineers
Designed by
Deepak Devulapally
Section No.
Elevation ft
Component Type
Condition Gov.
Load
Moment kip-ft
Minor Axis Moment kip-ft Max. Vx 35 0.00 0.00 0.00
T7 40 - 20 Leg Max Tension 7 119.97 -0.35 -0.00 Max. Compression 18 -143.43 1.00 0.02 Max. Mx 29 1.58 -1.18 -0.00 Max. My 4 -3.66 -0.00 -0.57 Max. Vy 29 0.32 -1.18 -0.00 Max. Vx 12 -0.17 -0.02 -0.54 Diagonal Max Tension 20 5.97 0.00 0.00 Max. Compression 20 -6.06 0.00 0.00 Max. Mx 33 -0.18 0.12 0.01 Max. My 35 -0.37 0.11 0.01 Max. Vy 33 0.07 0.10 0.01 Max. Vx 35 0.00 0.00 0.00
T8 20 - 0 Leg Max Tension 7 141.18 -0.84 -0.02 Max. Compression 18 -169.36 0.00 0.00 Max. Mx 29 3.88 -1.18 -0.00 Max. My 4 -5.15 -0.05 -1.76 Max. Vy 3 0.30 0.89 0.02 Max. Vx 4 -0.38 -0.05 -1.76 Diagonal Max Tension 8 7.22 0.00 0.00 Max. Compression 18 -7.62 0.00 0.00 Max. Mx 33 -0.73 0.18 0.02 Max. My 30 -1.96 0.17 -0.03 Max. Vy 33 0.08 0.18 0.02 Max. Vx 29 0.01 0.00 0.00
Maximum Reactions
Location Condition Gov.
Comb.
Vertical K
Horizontal, X K
Horizontal, Z K
Leg C Max. Vert 18 176.76 18.60 -10.49 Max. Hx 18 176.76 18.60 -10.49 Max. Hz 5 -131.96 -13.53 9.09 Min. Vert 7 -147.10 -15.78 8.86 Min. Hx 7 -147.10 -15.78 8.86 Min. Hz 18 176.76 18.60 -10.49
Leg B Max. Vert 10 176.09 -18.53 -10.53 Max.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .