MAXIMO.pdf
PDF 95 KB Posted
- Attached to
- Building 2600 and Building 11 New Wall/Door
- Solicitation number
- N4008526R9025
About this file
This is a MAXIMO Initial Equipment Inventory and Replacement/Update Form used for documenting mechanical and HVAC equipment in facilities. The form serves as a data collection instrument for recording existing equipment and tracking replacements or updates within a building management system.
The form captures essential identification information including the data collector's name, phone number, date, building number, and specific location within the facility. It provides an extensive checklist of equipment types across multiple categories: generators, air conditioning units (package and terminal), chillers (air-cooled and water-cooled in various configurations), compressors, pumps (circulating, condensate, condenser, and sump), heat exchangers, cooling towers, air handlers, fan coils, VAV units, boilers, water heaters, and various valves and regulators. For demolished or removed equipment, the form requires the MAXIMO number, serial number, and location. For new or replacement equipment, it requires manufacturer name, model number, serial number, equipment type (electric, oil, LP gas, natural gas, steam, or hot water), and comprehensive motor data including horsepower, voltage, phase, RLA, RPM, and frame size. Additional specifications include tons of capacity, number of motors, number of belts, kilowatts, and refrigerant type for cooling equipment. This standardized form enables facilities to maintain accurate inventories and track equipment lifecycle management across multiple building locations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Contractor Environmental Guide.pdf | ||
| Combined DIV 01 specs small projects.pdf | ||
| 26-0402- SUBMITTAL REGISTRY.pdf | ||
| 26-0402- SOW.pdf | ||
| 26-0402- PROJECT DESCRIPTION.pdf | ||
| RFP 260402.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MAXIMO Initial Equipment Inventory and Replacement/Update Form
Data Collector: Phone: Date: / / Bldg: Specific Location:
Type of Equipment:
Generator (Pad Mounted) AC, Package AC, Package Terminal
Assembly, Trap line Backflow Preventer (Size,Type) Chiller, Air Cooled Recip Chiller, Air Cooled Screw Chiller, Air Cooled Scroll Chiller, Water Cooled Recip Chiller, Water Cooled Screw Compressor, Control Air Compressor, Air (Recip) __ Compressor, Air (Screw) Dryer, Refrigerated Air Exchanger, Heat (plate, barrel) Fan, Exhaust (Belt or direct) __ Furnace, Oil
Heater, Space (Unit) Heat Pump, Geo-Thermal (Tons) Heat Pump, Indoor Unit (tons) Heat Pump, Outdoor Unit (tons)
__ Heat Pump, Package __Heat Pump, Package Terminal
Pump, Circulating Chilled Water Circulating, Domestic Water Pump, Circulating, Dual Temp Water Pump, Circulating, Heating Water Pump, Condensate Pump, Condenser (Cooling tower) Pump, Sump Regulator, Temperature Tank, Hot Water Storage Tower, Cooling Air Handler A: 0-24 tons Air Handler B: 25-50tons Air Handler C: = or >50 tons Computer room AHU Unit AC Condensing Unit, Freezer/Walk-in Condenser Unit, Refrigerator Condensing Unit, Fan Coil Unit, TAB (Attach Room No. List) Unit, VAV (Attach Room No. List) Valve, Pressure Reducing Valve, Steam Pilot Water Heater Boiler (input BTU)
Demolished/Removed Equipment
Maximo no: ______ Ser no: Location: _____
New/Replacement Equipment:
Manufacturer:
Model no:
Ser no:
Type: Elec Oil LP Gas Nat Gas Steam Hot Water
Motor Data: HP Volts Phase RLA RPM Frame
Tons No. of Motors no. of Belts
KW Refrig type