Hydro_Testing_for_SEBDs.pdf
PDF 248 KB Posted
- Attached to
- Underwater Egress Trainer Federal contract opportunity
- Solicitation number
- M67854-17-R-7800
- Issued by
- United States Marine Corps
About this file
Attachment 4 - Manuals
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Conformed_M67854-17-R-7800_0003.pdf | ||
| Attachment_05_Safety_Assessment_Report.pdf | ||
| Attachment_17__Question_and_Answers_March2017_ehm.xlsx | XLSX spreadsheet | |
| Attachment_14_-_15-5690_Rev.1.txt | TXT text file | |
| Oki_Consumable_RGFP_V4_2.pdf | ||
| Lejuene_Consumable_RGFP_V4_2.pdf | ||
| CmPendelton_Consumable_RGFP_V4_2.pdf | ||
| Hawaii_Consumable_RGFP_V4_2.pdf | ||
| M67854-17-R-7800_0003.pdf | ||
| M67854-17-R-7800_0002.pdf | ||
| M67854-17-R-7800_0001.pdf | ||
| M67854-17-R-7800.pdf | ||
| UET_PWS_6_Mar_2017.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2 3
Sept. 04, 2009 No. 09-001
SUBJECT: Hydrostatic Testing of Cylinders for SEA, HABD & BC’s
Affected Units: SEA & HABD Egress Systems and BC’s with DOT 3AL Cylinders •
1.5 cu.ft. (P/N 079105), 2.0 cu.ft. (P/N 079120 & 079107)) & 2.5 cu.ft. (P/N 079103) Problem: Requirement for 5 year Hydrostatic Testing•
SITUATION
It has come to Aqua Lung’s attention that there is some question about the requirement for hydrostatically testing these egress system DOT 3AL cylinders every 5 years. All DOT 3AL cylinders require annual visual inspection and hydrostatic testing every 5 years with few exceptions. As always, local command directives take precedence over manufacturers recommendations.
VISUAL INSPECTION
Aqua Lung recommends performing an annual visual inspection of the cylinder according to local regulations or to Com-pressed Gas Association (CGA) standards. These standards are found in CGA pamphlet CGA C-6.1-2002, “STAN-
DARDS FOR VISUAL INSPECTION OF HIGH PRESSURE ALUMINUM COMPRESSED GAS CYLINDERS”.
HYDROSTATIC TESTING
Aqua Lung recommends following the DOT regulation as these cylinders fall under the Note 1 exemption for diameter and length. This recommendation is in accordance with the Department Of Transportation (DOT) Title 49 CFR Ch-1 (10-1-01) Section 173.34, Qualification, maintenance and use of cylinders, Table “Retest and Inspection of Cylinders1”, Note 1. Any cylinder not exceeding two inches outside diameter and less than two feet in length is excepted from hydrostatic retest.
If you have any questions, please contact our Military Product Manager at 877-253-DIVE or 760-597-5048 rbedard@aqualung.com Your cooperation is much appreciated.
Key
Aqua Lung Part #
Air Volume cu/ft
Outside Dia. in.
Length in.
1 079103 2.5 1.99 11.38 2 079120 2.0 1.99 9.25 3 079107 2.0 1.99 9.25 4 079105 1.5 1.99 7.33
MILITARY TECHNICAL BULLETIN
Aqua Lung America • 2340 Cousteau Court • Vista, CA 92081 • (760) 597-5000 www.aqualung.com/military