Document Number 2916003 Rev:01
14 January 2009
BLOCK UPGRADE SYNCHRO RESOLVER SIMULATOR RETROFIT KIT
for the
VIPER/T (TETS) Station Development/Production Program
CDRL P002
Contract: M67854-05-D-3011 (Task Order 0008)
Security Classification: NONE
Prepared for:
UNITED STATES MARINE CORPS
Marine Corps Systems Command
2200 Lester Street Quantico, Virginia 22134-6050 Prepared by:
DME Corporation
Orlando Division
12889 Ingenuity Drive
Orlando, FL 32826 "DISTRIBUTION STATEMENT C. Distribution authorized to U.S. Government agencies and their contractors. (Reason: Operational Use). (Date: 5/26/03). Other requests for this document shall be referred to Marine Corps Systems Command."
PURPOSE:
The purpose of this modification, Synchro Resolver Simulator (SRS) Retrofit Kit, PN 93006N2800, is to enhance the capabilities of the TETS Secondary Instrument Assembly by adding the Plug-in Unit, Electronic Test Equipment, Synchro/Resolver PN 93006H2800. The modification kit consists of a modified Front Panel, Cable, Synchro/Resolver, Shorting Plug and attaching hardware.
TYPE OF MODIFICATION:
a. The modification kit, PN 93006N2800, is designed to add the test capabilities of the Synchro/Resolver Instrument PN 93006H2800.
Note: To perform this modification the IC retrofit fit kit part numbers 93006J4000 or 96006K4000 must be previously installed. PDU retrofit part number 93006H3000 may be installed but is not required.
b. The quantity and effected systems to be modified will be determined by the Government.
c. NA
d. Reference VIPER/T Interactive Electronic Technical Manual and MIL-STD-882B for
Standard Practice for System Safety.
END ITEMS TO BE MODIFIED:
Test System, Third Echelon, AN/USM-657(V)1, PN 93006A0000
Test System, Third Echelon, AN/USM-657(V)2, PN 93006B0000
Test System, Third Echelon, AN/USM-657(V)3, PN 93006E0000
ASSEMBLIES EFFECTED:
PN 93006A2000 Instrument Assembly, Secondary-Core, or PN 93006B2000 Instrument Assembly, Secondary, Radio Frequency, Assembly to be modified is determined by the Government.
COMPONENTS AFFECTED:
PN 93006A2120 Cover Assy, Electrical-Electronic Test & Measurement Equipment, Secondary Chassis, Core and sub assemblies or PN 93006B2120 Cover Assembly, Electrical-Electronic Test & Measurement Equipment, Secondary Chassis, RF and sub assemblies.
APPLICATION:
The skill level of personnel required to perform the block upgrade are: electronics technician and mechanical technician. These personnel should be familiar with computer system maintenance in both electrical and mechanical aspects.
Approximate time required for the block upgrade is 2 hours.
PARTS SUPPLIED/REQUIRED: SYNCHRO RESOLVER SIMULATOR RETROFIT KIT
See attachment A
TOOLS AND TEST EQUIPMENT:
No special tools or test equipment are required. Common hand tools are used.
ILLUSTRATIONS REQUIRED:
Reference: Synchro Resolver Simulator Retrofit Kit, PN 93006N2800 and figures 1 and 2.
MODIFICATION PROCEDURE:
1. Shutdown test station per shutdown procedures.
2. Remove cover assembly 93006A2120 from the 93006A2000 chassis.
3. Disconnect all cables connected to the secondary chassis cover assembly 93006A2120.
4. Remove blank panel 93006A1114 from the VXI chassis slot number 12.
5. Ensure the Synchro/Resolver plug-in unit (93006H2800) dip switch positions are set as shown in figure 1.
6. Install the Synchro/Resolver plug-in unit into VXI Chassis slot 12.
7. Refer to figure 2. Attach shielding gasket (93006H1132-3) and cable assembly (93006H2916) to the cover assembly (93006N2113) using supplied hardware.
8. Connect the P1 end of the cable assembly (93006H2916) to J1 of the Synchro/Resolver plug-in unit (93006H2800). Reconnect the cables removed in step 3.
9. Install the cover assembly (93006N2113) onto the VXI chassis. Ensure cables are not pinched or caught by the cover.
10. Startup the system.
11. After waiting the required station stabilization time of approximately 20 minutes, run the confidence test and the selftest modules.
* Note: The above retrofit procedure applies to all TETS configurations determined by the Government. To perform this modification the IC retrofit fit kit part numbers 93006J4000 or 96006K4000 must be previously installed. PDU retrofit part number 93006h3000 may be installed but is not required.
FIGURE 1
MODIFICATION RECORDING AGAINST EQUIPMENT AND MANUALS:
Once the block modification is completed a label (supplied by the Government) will be affixed to the 93006N2113 assembly to record the assigned modification number and the date of the modification.
MANUALS:
VIPER/T Interactive Electronic Technical Manual.
ATTACHMENT A