A1 - Window Layout (Final).pdf
PDF 2 MB Posted
- Attached to
- Marine Barracks Washington Window Tint Federal contract opportunity
- Solicitation number
- M549004590712
- Issued by
- United States Marine Corps
About this file
The provided document is a set of architectural drawings for exterior elevations, window details, and door schedules related to a federal contract opportunity. The drawings show the layout and specifications for window and door replacements at the Marine Barracks Washington facility. Key details include the requirement for new aluminum collapsible guardrails, aluminum handrails, modified bitumen roofing, window and door types and sizes, and hardware specifications. The related federal contract opportunity is for the Marine Barracks Washington Window Tint project, which is a Request for Quotations (RFQ) issued by the United States Marine Corps. The RFQ likely contains more details on the scope of work, submission requirements, and award terms, but those specifics are not included in the provided documents.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| E1 - Questions and Answers.docx | DOCX document | |
| C - Wage Determination DC20230002 (Final).pdf | ||
| A1 - PWS (Final).docx | DOCX document | |
| E1 - SF30 (Conformed Copy).pdf | ||
| E1 - SF30 (Modified Copy).pdf | ||
| A1 - Window Tinting Details (Final).xlsx | XLSX spreadsheet | |
| E1 - Marine Barracks Washington Site Visit.docx | DOCX document | |
| A1 - Window Tinting Details.pdf | ||
| C - Wage Determination 2015-4281.pdf | ||
| D1 - M0026424QD011.pdf | ||
| A1 - Window Layout.pdf | ||
| A3 - Brand Name (Signed).pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1
C1C1C1C1C1C1C1NNNNNNN
A4 A-301
A4 A-301
A2 A-301
A2 A-301
8.12
7.05 7.058.09
TYP.
8.13
TYP.
8.138.13
21 22 23 24
25 26 27 28 29 30 31 32
33 34 35 36 37 38 39 40 41 42
A1 A1 A1 A1
C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1
A1A1A1A1A1A1A1A1A1
E1 E1 G1 G1 G1 E1 E1
B1 B1 B1 B1 B1
C1
A1 A-301
A1 A-301
8.12
7.057.05 8.09
TYP.
5.08 5.075.07
8.13
TYP.
8.138.138.138.13 8.13
A B C
C1 A1
PM
BRANCH MANAGER
CHIEF ENG/ARCH
1394506, 1185564
N40080-119-D-0499
AS NOTED
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
Michael Baker International 100 Airside Drive Moon Township, PA 15108
CARDNO
2496 Old Ivy Road Suite 300 Charlottesville, VA 22903
FIRE PROTECTION
KEYPLAN
MR
LM
TC
GP
RMSJEWJEW
A-201
13105962
SCALE: 1/8" = 1'-0" C1EXTERIOR ELEVATIONS - WEST
SCALE: 1/8" = 1'-0" A1EXTERIOR ELEVATIONS - WEST
KEYNOTES
5.07 NEW ALUMINUM COLLAPSIBLE GUARDRAIL SET
BACK FROM EDGE OF PARAPET, CONTRACTOR
TO PROVIDE MOCK UP OF PLACEMENT TO
VERIFY SIGHT LINES
5.08 NEW ALUMINUM GUARDRAIL AND HANDRAIL
FOR BUGLER'S PLATFORM
7.05 REPAIR EXISTING GUTTERS AND DOWNSPOUTS
AS REQUIRED
8.09 NEW WINDOW, SEE A-611
8.12 8.13
SCALE: 1/8" = 1'-0"
0 4'-0" 8'-0" 16'-0"
123456789101112131415161718192021
A3 A3 A3 A3 A3
D2 D2 D2 D2 D2 D2
A4
D2
A4 A3
D2 D2 D2 D2 D2 D2 D2 D2 D2
A3A3A3A3A3A3A3A3
M
G2
L L
A4 A-301
A4 A-301
A2 A-301
A2 A-301
7.05 7.05
8.12
8.13
8.09
TYP.
41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62
A2 A2 A2
C1 C1 C1
A1 A1 A1
C1 C1 C1 C1 C1
A1 A1 A1 A1
C1 C1
A1 A1
C1 C1
A1 F1 F1 F1 F1
8.085.06
8.12
7.05 5.03
TYP.
8.09
TYP.
8.13
7.03
A2 A-502
8.13
A-101SCALE: 1/8" = 1'-0" A1EXTERIOR ELEVATIONS - EAST
A-402SCALE: 1/8" = 1'-0" C1EXTERIOR ELEVATIONS - WEST
A B C
C1
A1
PM
BRANCH MANAGER
CHIEF ENG/ARCH
1394506, 1185564
N40080-119-D-0499
AS NOTED
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
Michael Baker International 100 Airside Drive Moon Township, PA 15108
CARDNO
2496 Old Ivy Road Suite 300 Charlottesville, VA 22903
FIRE PROTECTION
KEYPLAN
MR
LM
TC
GP
RMSJEWJEW
A-202
13105963
KEYNOTES
5.03 GALV STEEL GRATING OVER ELEVATOR SUMP
PIT, SEE STRUCTURAL DRAWINGS
5.06 DIVIDER BEAM, SEE STRUCTURAL DRAWINGS
7.03 NEW MODIFIED BIT ROOF OVER BREEZEWAY
7.05 REPAIR EXISTING GUTTERS AND DOWNSPOUTS
AS REQUIRED
8.08
8.09 NEW WINDOW, SEE A-611
8.12 8.13
222324
2526272829303132
33343536373839404142
A3 A3 A3 A3
C2C2C2 C2 C2 C2 C2
A3A3A3A3 A3
C2 C2 C2 C2 C2
B2 B2 B2 B2 B2
C2
E2 E2 G1 G1 G1 E2 E2
A3 A3 A3 A3
D2aD2D2D2
J J J J J J J
J J L L L L
A1 A-301
8.12
7.05 7.05
8.12
5.075.07 5.08
TYP.
8.09
TYP.
8.13
4.08
41424344454647484950515253545556575859606162
F2 F2 F2 F2
E2 E2
A3 A3 A3 A3 A3 A3 A3 A3 A3
C2C2C2C2C2C2C2C2C2
A3 A3 A4 A4 A4
C2C2C2C2C2
H K K K K K K K K K J J
8.08
8.11
8.11 8.11
7.05
8.12
8.09
TYP.
A2 A-502
8.11
A B C
C1 A1
PM
BRANCH MANAGER
CHIEF ENG/ARCH
1394506, 1185564
N40080-119-D-0499
AS NOTED
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
Michael Baker International 100 Airside Drive Moon Township, PA 15108
CARDNO
2496 Old Ivy Road Suite 300 Charlottesville, VA 22903
FIRE PROTECTION
KEYPLAN
MR
LM
TC
GP
RMSJEWJEW
A-203
13105964
A-101SCALE: 1/8" = 1'-0" C1EXTERIOR ELEVATIONS - EAST
A-101SCALE: 1/8" = 1'-0" A1EXTERIOR ELEVATIONS - EAST
KEYNOTES
4.08 INFILL MASONRY WHERE DOOR WAS REMOVED
AND PROVIDE NEW WINDOW OPENING
5.07 NEW ALUMINUM COLLAPSIBLE GUARDRAIL SET
BACK FROM EDGE OF PARAPET, CONTRACTOR
TO PROVIDE MOCK UP OF PLACEMENT TO
VERIFY SIGHT LINES
5.08 NEW ALUMINUM GUARDRAIL AND HANDRAIL
FOR BUGLER'S PLATFORM
7.05 REPAIR EXISTING GUTTERS AND DOWNSPOUTS
AS REQUIRED
8.08
8.09 NEW WINDOW, SEE A-611
8.11 DOOR PANEL - SEE SCHEDULE
8.12 8.13
C B.9 B A
F2 F2 F2
A2
5.03
8.08
5.06
8.128.12
5.08
5.07
7.06
TYP.
CA
G2 G1
5.03
8.12
5.08
5.07
7.03
TYP.
C B.9 A
G1 G2
5.07
8.12
TYP.
5.08
A B C
C1A3 A1
PM
BRANCH MANAGER
CHIEF ENG/ARCH
1394506, 1185564
N40080-119-D-0499
AS NOTED
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
Michael Baker International 100 Airside Drive Moon Township, PA 15108
CARDNO
2496 Old Ivy Road Suite 300 Charlottesville, VA 22903
FIRE PROTECTION
KEYPLAN
MR
LM
TC
GP
RMSJEWJEW
A-204
13105965
A-141SCALE: 1/8" = 1'-0" C1SOUTH ELEVATION
A-131SCALE: 1/8" = 1'-0" A3NORTH ELEVATION - CENTRAL TOWER
A-131SCALE: 1/8" = 1'-0" A1SOUTH ELEVATION - CENTRAL TOWER
KEYNOTES
5.03 GALV STEEL GRATING OVER ELEVATOR SUMP
PIT, SEE STRUCTURAL DRAWINGS
5.06 DIVIDER BEAM, SEE STRUCTURAL DRAWINGS
5.07 NEW ALUMINUM COLLAPSIBLE GUARDRAIL SET
BACK FROM EDGE OF PARAPET, CONTRACTOR
TO PROVIDE MOCK UP OF PLACEMENT TO
VERIFY SIGHT LINES
5.08 NEW ALUMINUM GUARDRAIL AND HANDRAIL
FOR BUGLER'S PLATFORM
7.03 NEW MODIFIED BIT ROOF OVER BREEZEWAY
7.06 TIE NEW COPPER GUTTER AND DOWNSPOUT
INTO EXISTING ADJACENT DOWNSPOUT
8.08 8.12
F3
DOUBLE
MASONRY HEAD
2"
PER
SCHEDULE 2"
F1
MASONRY HEAD
2"
PER
SCHEDULE 2"
PER
SCHEDULE
B
FLUSH
PER
SCHEDULE
DD
DOUBLE FLUSH
2"
F2
TRANSOM
PER
SCHEDULE
PER
SCHEDULE
CC
DOUBLE FLUSH
PER
SCHEDULE
BB
DOUBLE PANELED
PER
SCHEDULE
AA
DOUBLE
PANELED W/
GLASS
A
PANELED
GLASS PANELS
GL-1
NOTE:
CONTRACTOR TO VERIFY ALL EXISTING DOOR
DIMENSIONS AND QUANTITIES AND STYLES.
SEE SPECIFICATION FOR GLASS TYPES (GL)
PER SCHEDULE
TRANSOM TO
MATCH SIZE OF
EXISTING DOOR
TRANSOMS
A2 OPERABLE
B1
OPERABLE
C1
OPERABLE
E1
OPERABLE
F1
OPERABLE
G1
OPERABLE
4'-0"
4'-0" 4'-0"
3'-0" 3'-0" 4'-0"
H KJ
3'-0" 4'-0"
4'-0"
A3
NON
OPERABLE
4'-0"
B2
4'-0"
C2
4'-0"
D2
4'-0"
E2
NON
OPERABLE
3'-0"
F2
3'-0"
G2
4'-0"
NON
OPERABLE
NON
OPERABLE
NON
OPERABLE
NON
OPERABLE
NON
OPERABLE
A1 OPERABLE
4'-0"
A4
NON
OPERABLE
4'-0"
NON
OPERABLE
NON
OPERABLE
NON
OPERABLE
NOTE:
CONTRACTOR TO VERIFY ALL EXISTING
WINDOW DIMENSIONS AND QUANTITIES.
SEE SPECIFICATION FOR GLASS TYPES
(GL). SEE A-612 FOR TYPICAL WINDOW
DETAILS
GL-2 GL-2 GL-3 GL-3 GL-2 GL-3 GL-2 GL-3
GL-3
GL-2 GL-3 GL-2 GL-3
GL-3 GL-3 GL-3
GL-2 GL-3
L
4'-0"
NON
OPERABLE
GL-3
D2a
4'-0"
NON
OPERABLE
GL-3
M
4'-0"
NON
OPERABLE
GL-3
PM
BRANCH MANAGER
CHIEF ENG/ARCH
1394506, 1185564
N40080-119-D-0499
AS NOTED
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
Michael Baker International 100 Airside Drive Moon Township, PA 15108
CARDNO
2496 Old Ivy Road Suite 300 Charlottesville, VA 22903
FIRE PROTECTION
MR
LM
TC
GP
RMSJEWJEW
A-611
13105981
1/4" = 1'-0"
EXTERIOR DOOR TYPES
1/4" = 1'-0"
WINDOW TYPES
EXTERIOR DOOR SCHEDULE
SIZE DOOR FRAME
DETAI
LS
HARDWARE
SET COMMENTS ATFPFINISH TYPE DESCRIPTION FINISH
100 7' - 0" 5' - 8" 1 3/4" BB STEEL (INSULATED) PT F3 HOLLOW
METAL
PT EX-1 X
128 7' - 0" 3' - 0" 1 3/4" B HOLLOM METAL
(INSULATED)
PT F1 HOLLOW
METAL
PT EX-2 X
129 7' - 0" 3' - 8" 1 3/4" A HOLLOM METAL
(INSULATED)
PT F2 HOLLOW
METAL
PT EX-2 X
132 7' - 0" 6' - 0" 1 3/4" AA HOLLOM METAL
(INSULATED)
PT F3 HOLLOW
METAL
PT EX-1 X
133 7' - 0" 3' - 8" 1 3/4" A HOLLOM METAL
(INSULATED)
PT F1 HOLLOW
METAL
PT EX-2 X
138 7' - 0" 3' - 0" 1 3/4" A HOLLOM METAL
(INSULATED)
PT F1 HOLLOW
METAL
PT EX-2 X
B103 7' - 0" 5' - 8" 1 3/4" DD STEEL (INSULATED) PT F3 STANDARD
STEEL
PT EX-1
ST-1 7' - 0" 6' - 0" 1 3/4" CC HOLLOM METAL
(INSULATED)
PT F3 HOLLOW
METAL
PT EX-3
ST-2 7' - 0" 3' - 0" 1 3/4" A HOLLOM METAL
(INSULATED)
PT F1 HOLLOW
METAL
PT EX-2
ST-3 7' - 0" 3' - 8" 1 3/4" A HOLLOM METAL
(INSULATED)
PT F1 HOLLOW
METAL
PT EX-2
ST-4 7' - 0" 3' - 0" 1 3/4" A HOLLOM METAL
(INSULATED)
PT F1 HOLLOW
METAL
PT EX-2
ST-5a 7' - 0" 6' - 0" 1 3/4" CC HOLLOM METAL
(INSULATED)
PT F3 HOLLOW
METAL
PT EX-1
ST-5b 7' - 0" 5' - 8" 1 3/4" BB STEEL (INSULATED) PT F3 STANDARD
STEEL
PT EX-3
ST-6 7' - 0" 3' - 0" 1 3/4" A HOLLOM METAL
(INSULATED)
PT F1 HOLLOW
METAL
PT EX-2
SCALE: 1/4" = 1'-0"
0 2'-0" 4'-0" 8'-0"
File details come from the government source that posted it. Updated .