This is a Lead-Based Paint Chip Sampling Report prepared by SUMMIT Engineering, Laboratory & Testing, Inc. for the McCelvey Center Museum located at 212 E. Jefferson Street, York, South Carolina 29745. The inspection was conducted on April 25, 2023, and the report was issued on May 4, 2023, by EPA-licensed environmental managers Matthew A. Hoffman and John C. Hayes. The sampling was performed to support planned renovation activities at the facility, which is operated by Culture & Heritage Museums of York County. A total of two paint chip samples were collected from interior areas designated for renovation. The testing was limited to paint chip analysis for RCRA disposal and OSHA compliance purposes and did not constitute a comprehensive HUD/EPA lead-based paint inspection.
The sampling results identified one paint sample—pink interior wall and ceiling paint—that exceeded South Carolina's lead-based paint disposal threshold of 0.07% by weight, with a concentration of 0.20% by weight, though it remained below the federal standard of 0.5% by weight. The pink paint was found on interior walls and ceilings throughout the renovation areas of the auditorium. A second sample of white paint on wood support beams under the stage was tested and found not to meet the definition of lead-based paint. All personnel conducting the inspection maintained current EPA and/or State lead risk assessor and inspector licenses, as documented in the report's appendices. This sampling report is directly relevant to the concurrent McCelvey Center Fire Notification and Auditorium HVAC Replacement contract opportunity, as lead-based paint remediation may be a consideration during the auditorium renovation work.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LEAD-BASED PAINT CHIP SAMPLING REPORT
MCCELVEY CENTER MUSEUM
YORK, SC 29745
CLIENT:
Ms. Sara Johnson Culture & Heritage Museums
1444 Brattonsville Road MCConnells, SC 29726
LOCATION:
212 E. Jefferson Street, #A York, SC 29745
DATE OF INSPECTION:
April 25, 2023
DATE OF REPORT:
May 4, 2023
PREPARED BY:
Matthew A. Hoffman Environmental Manager
John C. Hayes
Environmental Manager EPA Lead Inspector No. LBP-I-I179827-2
Expiration Date: March 24, 2024
SUMMIT Engineering, Laboratory & Testing, Inc. (SUMMIT) A Universal Engineering Sciences, Inc. Company
3575 Centre Circle Fort Mill, SC 29715
704-504-1717 EPA Lead Certification No. LBP-66475-3
SUMMIT Job No. 0545.E0001
Lead-Based Paint Chip Sampling SUMMIT Project No. 0545.E0001 212 E. Jefferson St, #A, York, SC May 4, 2023 i
LEAD-BASED PAINT CHIP SAMPLING REPORT
212 E JEFFERSON STREET, #A
YORK, SC 29745
TABLE OF CONTENTS
SECTION PAGE
1.0 EXECUTIVE SUMMARY
2.0 SCOPE OF INSPECTION
2.1 BUILDING BACKGROUND
2.2 TRAINING
2.3 INSPECTION COMPANY
2.4 FINDINGS
3.0 CONCLUSIONS AND RECOMMENDATIONS
4.0 QUALIFICATIONS
5.0 SIGNATURE OF ENVIRONMENTAL PROFESSIONAL
LIST OF ATTACHMENTS
• Analytical Results
• Lead-Based Paint Licenses
• Summit Documentation
1.0 EXECUTIVE SUMMARY
SUMMIT performed Lead-Based Paint Chip sampling for the commercial structure located at 212 E. Jefferson St, #A in York, SC. The structure is currently intended to be renovated. The collected data is located in Appendix A.
On April 25, 2023, SUMMIT personnel collected a total of two (2) paint chip samples from interior areas of the building planned for renovation.
One (1) paint chip sample was found to have lead concentrations below the federal lead-based paint standard of 0.5% by weight, but greater than the SC threshold for LBP disposal of 0.07% by weight. The pink interior wall and ceiling paint surpasses the SC threshold for LBP. The paint is located on the interior walls and ceilings throughout the renovation areas.
None of the other sampled paints meet the definition of lead-based paint.
2.0 SCOPE OF INSPECTION
2.1 BUILDING BACKGROUND
SUMMIT performed Lead-Based Paint Chip sampling for the commercial building located at 212 E.
Jefferson Street, #A in York, South Carolina. The building is occupied by the McCelvey Center. No records were available for review to determine the type of materials used during the construction. No construction records were available to determine when the structure was painted or what the structure was painted with.
This Lead-Based Paint Chip Sampling does not follow the HUD/EPA guidelines for a lead-based paint inspection and is limited to only the paint types tested. The LBP testing was performed for RCRA disposal and OSHA compliance purposes.
2.2 TRAINING
All inspectors utilized by SUMMIT have EPA and/or State licensure and are licensed Lead Risk Assessors and/or Inspectors. Current lead-based paint licenses can be found in Appendix B.
2.3 INSPECTION COMPANY
The inspection was performed by an inspector and/or risk assessor employed by SUMMIT, 3575 Centre Circle, Fort Mill, South Carolina, 29715. SUMMIT’s telephone number is (704) 504-1717. SC Firm Certification No. LBP-66475-1.
2.4 FINDINGS
The following paints were tested on the structures:
SAMPLE NAME LOCATION MATERIAL/DESCRIPTION CONCENTRATION
% BY WEIGHT
LBP
(Y/N)
Pink 1 Auditorium PINK WALLS/CEILINGS 0.20% Y
WH 1
Wood support beams under stage
WHITE/SUPPORT BEAMS <0.060% N
One (1) paint chip sample was found to have lead concentrations below the federal lead-based paint standard of 0.5% by weight, but greater than the SC threshold for LBP disposal of 0.07% by weight. The pink interior wall and ceiling paint surpasses the SC threshold for LBP. The paint
3.0 CONCLUSIONS
SUMMIT performed Lead-Based Paint Chip sampling for the commercial structure located at 212 E. Jefferson Stret, #A in York, SC. The structure is currently intended to be renovated. The collected data is located in Appendix A.
On April 25, 2023, SUMMIT personnel collected a total of two (2) paint chip samples from interior areas of the building.
One (1) paint chip sample was found to have lead concentrations below the federal lead-based paint standard of 0.5% by weight, but greater than the SC threshold for LBP disposal of 0.07% by weight. The pink interior wall and ceiling paint surpasses the SC threshold for LBP. The paint
4.0 QUALIFICATIONS
The environmental professionals for this project are listed below.
Mr. Hoffman has over twenty-two years of experience in the environmental field. He is a proficient environmental consultant and an Environmental Branch Manager for SUMMIT. Mr.
Hoffman has experience in Underground Storage Tanks, Soil and Groundwater Testing, Phase I/II/III Environmental Site Assessments, Asbestos, Hazardous Waste, Remediation Systems, Indoor Air Quality, Lead Based Paint Surveys, Landfill Gas Monitoring, Special Inspections and Project Management.
5.0 SIGNATURE OF ENVIRONMENTAL PROFESSIONAL
SUMMIT appreciates this opportunity to provide these services to you. If you should have any questions, please feel free to contact us at (704) 504-1717.
Sincerely, SUMMIT
John Hayes Environmental Professional SC Lead Inspector No. LBP-I-I179827-2 Expiration Date: March 24, 2024 SC EPA Firm License No. LBP-66475-3
Matthew A. Hoffman, E.I.
Environmental Department Manager – Charlotte/Columbia Offices
APPENDIX A
SUMMIT Engineering, Laboratory & Testing, Inc.
3575 Centre Circle Fort Mill, SC 29715
04-25-23 04-27-23Analyzed:
LABORATORY REPORT
LEAD IN PAINT
Lab Code: SC230047
LAB ID
Received:
CLIENT ID
McCelvey Center; 0545.E0001Project:
Client:
PPM (µg/g) CONCENTRATION
% BY WEIGHT
2752 Pleasant Rd Suite 100A • Fort Mill, SC 29708
TEL: 803-526-5146
METHOD: EPA SW846 7000B
04-28-23Reported:
Pink 1 SCA0697 0.202000 Sample contains substrate, potentially affecting results
WH 1 SCA0698 0.060600
Sample contains substrate, potentially affecting results
LEGEND µg = microgram ml = milliliter ppm = parts per million Pb = lead g = grams
Reviewed By:
This method has been validated for sample weights of 0.020g or greater. When samples with a weight of less than that are analyzed those results fall outside of the scope of accreditations.
* The analysis of composite wipe samples as a single samples is not included under AIHA accreditation.
Minimum reporting limit is 10 µg total lead. Sample results denoted with a “less than” (<) sign contain less than 10.0 µg total lead, based on a 40ml sample volume.
REGULATORY
LIMITS
Federal Lead Standard / HUD: 0.5% lead by weight.
wt = weight
Consumer Products Safety Standard: Greater than 0.009% lead by weight.
OSHA Standard: No safe limit.
Lead samples are not analyzed by Eurofins CEI Lead samples are submitted to an AIHA ELLAP accredited laboratory for lead analysis of soil, dust, paint, and TCLP samples.
Laboratory results represent the analysis of samples as submitted by the client. Information regarding sample location, description, area, volume, etc., was provided by the client. Unless notified in writing to return samples, Eurofins CEI discards client samples after 30 days. This report shall not be reproduced, except in full, without the written consent of Eurofins CEI.
Information provided by customer includes customer sample ID, location, volume and area as well as date and time of sampling.
Tianbao Bai, Ph.D.
Laboratory Director
End of Report
Page 12752 Pleasant Rd Suite 100A • Fort Mill, SC 29708 • 803.526.5146
APPENDIX
SUMMIT ELT, Inc.
has fulfilled the requirements of the Toxic Substances Control Act (TSCA) Section 402, and has received certification to conduct lead-based paint activities pursuant to 40 CFR Part 745.226
All EPA Administered Lead-based Paint Activities Program States, Tribes and Territories
This certification is valid from the date of issuance and expires November 29, 2025
Certification #
LBP-66475-3
Issued On
November 29, 2022
Michelle Price, Chief
Lead, Heavy Metals, and Inorganics Branch
SUMMIT ELT, Inc.
has fulfilled the requirements of the Toxic Substances Control Act (TSCA) Section 402, and has received certification to conduct lead-based paint renovation, repair, and painting activities pursuant to 40 CFR Part 745.89
All EPA Administered States, Tribes, and Territories
This certification is valid from the date of issuance and expires August 19, 2035
Certification #
NAT-66475-5
Issued On
November 29, 2022
Michelle Price, Chief
Lead, Heavy Metals, and Inorganics Branch
APPENDIX
Lead based Paint Survey SUMMIT UES Project No. 0545.E0001 McCelvey Center Museum York, Southy Carolina 29745 May 4, 2023
View of Auditorium showing pink paint
View of white paint on support beam