LBP Bldg. 12 (soffit & fascia).pdf

PDF 121 KB Posted

Attached to
B12 Roof Repairs Federal contract opportunity
Solicitation number
W911SG25BA015
Issued by
Department of the Army Materiel Command Mission and Installation Contracting Command Fort Hood

About this file

This document is an LBP (Lead-Based Paint) Testing Data Sheet for a roof replacement project at Building Number 12. The testing was conducted on 4/23/2025 using a Viken/Pb200e XRF instrument, with inspectors Frank Lujan and Paul Rodriguez. The data sheet reveals four test locations on wood soffits and fascias, all located at the east and north ends of the building. Each tested component was classified as "POSITIVE" for lead-based paint, with XRF readings ranging from 2.4 to 4.2 mg/cm², and all were rated in "POOR" condition. The document notes that the testing conforms to the Texas Department of State Health Services lead measurement standard of 1.0 mg/cm² by X-ray fluorescence, with calibration readings deemed acceptable.

View the file

Other files for this federal contract opportunity

Other files attached to B12 Roof Repairs, newest first.
File Type Posted
Abstract of Offerors OF_1419 Page 3.pdf PDF
Abstract of Offerors OF_1419 Page 1 1.pdf PDF
Abstract of Offerors OF_1419 Page 2.pdf PDF
B12 RFI Answers.pdf PDF
Original As-built Drawings.pdf PDF
Site Visit sign-in sheet.pdf PDF
Wage Determination.txt TXT text file
Asbestos survey 19696 Cherokee Bldg. 12.pdf PDF
Drawings_FY25_Building 12.pdf PDF
Solicitation - W911SG25BA015..pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LBP TESTING DATA SHEET

Facility Information: Roof replacement

Facility Name: Building Number: 12

XRF Model and M/N: Viken/Pb200e Date of Assessment: 4/23/2025

XRF Instrument S/N: 2759 Inspector Name(s): Frank Lujan/Paul Rodriguez

Data Sheet

SA

M

P

LE

I D

SU

B

ST

R

A

TE

C O

M P

N

EN

T

C O

LO

R

O F

C O

M P

O N

EN

T

TE

ST

L O

C A

TI

N

D

ES

C R

IP

TI

X R

F R

EA

D

IN

G

(m g/ cm ²)

LA

SS

IF

IC

A

TI

N D

IT

IO

N/A N/A N/A Green Calibration (< 0.00) .1 ACCEPTABLE N/A

N/A N/A N/A Green Calibration (0.8 to 1.2) 1.0 ACCEPTABLE N/A

LBP-01 Wood Soffit Green East end 3.7 POSITIVE POOR

LBP-02 Wood Fascia Green East end 2.4 POSITIVE POOR

LBP-03 Wood Fascia Green North end 4.2 POSITIVE POOR

LBP-04 Wood Soffit Green North end 3.3 POSITIVE POOR

NOTES:

DPW-ED conforms to Texas Department of State Health Services lead measurement standard, 1.0mg/cm2 by X-ray fluorescence.