LBP Bldg. 12 (soffit & fascia).pdf
PDF 121 KB Posted
- Attached to
- B12 Roof Repairs Federal contract opportunity
- Solicitation number
- W911SG25BA015
About this file
This document is an LBP (Lead-Based Paint) Testing Data Sheet for a roof replacement project at Building Number 12. The testing was conducted on 4/23/2025 using a Viken/Pb200e XRF instrument, with inspectors Frank Lujan and Paul Rodriguez. The data sheet reveals four test locations on wood soffits and fascias, all located at the east and north ends of the building. Each tested component was classified as "POSITIVE" for lead-based paint, with XRF readings ranging from 2.4 to 4.2 mg/cm², and all were rated in "POOR" condition. The document notes that the testing conforms to the Texas Department of State Health Services lead measurement standard of 1.0 mg/cm² by X-ray fluorescence, with calibration readings deemed acceptable.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Abstract of Offerors OF_1419 Page 3.pdf | ||
| Abstract of Offerors OF_1419 Page 1 1.pdf | ||
| Abstract of Offerors OF_1419 Page 2.pdf | ||
| B12 RFI Answers.pdf | ||
| Original As-built Drawings.pdf | ||
| Site Visit sign-in sheet.pdf | ||
| Wage Determination.txt | TXT text file | |
| Asbestos survey 19696 Cherokee Bldg. 12.pdf | ||
| Drawings_FY25_Building 12.pdf | ||
| Solicitation - W911SG25BA015..pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LBP TESTING DATA SHEET
Facility Information: Roof replacement
Facility Name: Building Number: 12
XRF Model and M/N: Viken/Pb200e Date of Assessment: 4/23/2025
XRF Instrument S/N: 2759 Inspector Name(s): Frank Lujan/Paul Rodriguez
Data Sheet
SA
M
P
LE
I D
SU
B
ST
R
A
TE
C O
M P
N
EN
T
C O
LO
R
O F
C O
M P
O N
EN
T
TE
ST
L O
C A
TI
N
D
ES
C R
IP
TI
X R
F R
EA
D
IN
G
(m g/ cm ²)
LA
SS
IF
IC
A
TI
N D
IT
IO
N/A N/A N/A Green Calibration (< 0.00) .1 ACCEPTABLE N/A
N/A N/A N/A Green Calibration (0.8 to 1.2) 1.0 ACCEPTABLE N/A
LBP-01 Wood Soffit Green East end 3.7 POSITIVE POOR
LBP-02 Wood Fascia Green East end 2.4 POSITIVE POOR
LBP-03 Wood Fascia Green North end 4.2 POSITIVE POOR
LBP-04 Wood Soffit Green North end 3.3 POSITIVE POOR
NOTES:
DPW-ED conforms to Texas Department of State Health Services lead measurement standard, 1.0mg/cm2 by X-ray fluorescence.