Landscape_Plan_For_Bid.pdf

PDF 1 MB Posted

Attached to
Grayton Beach Community Center
Solicitation number
ITB 24-35
Issued by
Walton County, Florida

About this file

The document is a landscape and irrigation plan for the Grayton Beach Restroom Facility, prepared by Dewberry Associates for Walton County, Florida. The plan, labeled L-1 and L-2, details the landscape design and irrigation system for a 2,000-square-foot restroom facility located in Grayton Beach. The site plan includes a comprehensive planting schedule featuring various native plant species such as Sand Live Oak, Saw Palmetto, Dune Sunflower, and other coastal grassland vegetation. The design emphasizes preservation of existing vegetation, with a 10-foot buffer around the structure to retain the coastal grassland areas.

The irrigation plan specifies a detailed irrigation system using Hunter PVG valves, Rain Bird ESP controllers, and a 3-station node with Schedule 40 PVC piping. The system includes different irrigation zones: a bubbler zone with Hunter PCN bubblers, a Netafim drip irrigation zone, and a micro spray zone designed for efficient irrigation. The planting and irrigation design appears to be carefully crafted to maintain the natural coastal ecosystem while providing necessary infrastructure for the restroom facility. The documents are dated 6/3/24 and include technical details for plant placement, irrigation setup, and preservation of the existing landscape.

View the file

Other files

File Type Posted
Grayton_Beach_Community_Center_(Addendum_#1_Revision).pdf PDF
Grayton_Beach_Community_Center_(Addendum_#1_Revision).pdf PDF
QA_#4_9-30-2024_(1)_FENCE.pdf PDF
QA_#4_9-30-2024_(1)_FENCE.pdf PDF
50150591_Bid_Schedule_8-21-2024.pdf PDF
50150591_Bid_Schedule_8-21-2024.pdf PDF
Contract_No._24-35.pdf PDF
Contract_No._24-35.pdf PDF
Public_Construction_Bond.pdf PDF
Public_Construction_Bond.pdf PDF
Landscape_Plan_For_Bid.pdf PDF
STRUCTURAL_BID_TDC_GRAYTON_BEACH.pdf PDF
STRUCTURAL_BID_TDC_GRAYTON_BEACH.pdf PDF
50150591_ALTERNATE-Bid_Schedule_8-21-2024.pdf PDF
24019_MECHANICAL_BID.pdf PDF
50150591_Grayton_Beach_RR_2024-8-21_Civil_Bid_Set.pdf PDF
24019_PLUMBING_BID.pdf PDF
240724_GRAYTON_BEACH_PAVILION_RELEASE_FOR_BID.pdf PDF
2215-GRAYTON_BEACH_BID_240822.pdf PDF
Alternate_Bid_Item_DEFUNIAK_ST_DRAFT_PLANS.pdf PDF
24019_MECHANICAL_BID.pdf PDF
50150591_Grayton_Beach_Restroom_Specs_8-21-2024.pdf PDF
Alternate_Bid_Item_DEFUNIAK_ST_DRAFT_PLANS.pdf PDF
2215-GRAYTON_BEACH_BID_240822.pdf PDF
24019_PLUMBING_BID.pdf PDF
240724_GRAYTON_BEACH_PAVILION_RELEASE_FOR_BID.pdf PDF
50150591_Grayton_Beach_Restroom_Specs_8-21-2024.pdf PDF
50150591_Grayton_Beach_RR_2024-8-21_Civil_Bid_Set.pdf PDF
50150591_ALTERNATE-Bid_Schedule_8-21-2024.pdf PDF
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D

EW

BE

R

R Y

A

SS

O C

IA

TE

S G

R A

YT

O

N R

ES

TR

O O

M F

A C

IL

IT

Y W

A

LT

O N

C O

U N

TY

, F

LO

R

ID

A

L-d a te r e vi sio n point washington, florida bradfordrdavis@gmail.com telephone 850.974.0616 fl 0001730

340 oak avenue

6/ 3/

ROOT BALL FLUSH

WITH FINISH GRADE

SCARIFY ROOTBALL

MULCH: 4" AFTER SETTLEMENT

EXISTING SOIL

PUDDLE, SETTLE, &

PLANTING BACKFILL:

AIR POCKETS.

COMPACT TO REMOVE

2x ROOTBALL

SHRUB PLANTING

NTS

4" WATERING

4" MULCH

BERM

NTS

TREE PLANTING/GUYING

ROOT BALL FLUSH

WITH FINISH GRADE

TOP OF STAKES 2"

BELOW FINISH GRADE

WITH 120° SEPARATION

SCARIFY ROOT BALL

PLANTING BACKFILL:

PUDDLE, SETTLE, &

COMPACT TO REMOVE

AIR POCKETS.

SEE SPECS.

GUYS (3 REQ'D)

APPLY PER MNFT.S INSTRUCTIONS

OSMOCOTE FERTILIZER2x ROOTBALL

OSMOCOTE FERTILIZER

SCARIFY

ROOT BALL

guy wires shall be removed at the end of the guarantee period.

6. All trees over eight (8) feet high shall be staked and guyed on three sides. See detail. All

5. All planting beds shall be clean white beach sand to be raked free of any debris.

driveways, and parking areas.

behind (12" for groundcover) bedlines at lawns or walks and minimum 36" back from curbs, from building or as required by conditions. Front row of shrubs shall be planted a minimum of 24"

4. Back row of shrubs shall be planted 36" from face of building wall, groundcovers shall be 12"

3. Plants shall be set so that the top of the rootball is flush with finish grade after settlement.

rootballs to prevent plant from becoming pot-bound. all2. Scarify

PLANTING NOTES

PLANTING DETAILS

PLANTING SCHEDULE

1. Plants to be sourced from a reputable nursery supplier, to be well established, meet Florida Fancy Grade standards, trees to be full to the ground, multi trunk with at least 5 leaders.

UP

EXISTING VEGETATION SHALL

BE PRESERVED (SEE

PRESERVATION NOTE).

PRESERVATION AREA

COASTAL GRASSLAND AREAS OUTSIDE

STRUCTURES 10-FT BUFFER SHALL BE

PRESERVED AND RETAINED.

PRESERVATION AREA

COASTAL GRASSLAND AREAS OUTSIDE

STRUCTURES 10-FT BUFFER SHALL BE

PRESERVED AND RETAINED.

Saw Palmetto#726 Serenoa repens

Muhly Grass#127 Muhlenbergia capillaris

Dwf. Yaupon HollyIlex vomitoria 'Schillings Dwf.'#3 43

Spiderwort#146 Conradina canescens

Sea Oats4"62 Uniola paniculata

Sand Live Oak#3030 Quercus geminata

Myrtle Oak#1513 Quercus myrtlefolia

(Gel Packs) to replace canopy trees at 3:1

Dune Sunflower#124 Helianthus debilis

EXISTING VEGETATION SHALL

BE PRESERVED (SEE

PRESERVATION NOTE).

EXISTING VEGETATION SHALL

BE PRESERVED (SEE

PRESERVATION NOTE).

10' 20'5'0' 2'

SCALE 1" = 10' - 0"

AutoCAD SHX Text

D

EW

BE

R

R Y

A

SS

O C

IA

TE

S G

R A

YT

O

N B

EA

C

H R

ES

TR

O O

M F

A C

IL

IT

Y W

A

LT

O N

C O

U N

TY

, F

LO

R

ID

A

L-d a te r e vi sio n point washington, florida bradfordrdavis@gmail.com telephone 850.974.0616 fl 0001730

284 oak avenue

6/ 3/

IRRIGATION NOTES

AND DRAIN SYSTEM TO PREVENT FREEZE DAMAGE.

8. WHEN TEMPERATURES FALL BELOW 40 DEGREES FAHRENHEIT DISCONNECT

7. CONTROL VALVES TO BE PLACED IN 6" ROUND VALVE BOXES.

6. USE 3M DBY SPLICE KITS AT ALL CONNECTION POINTS.

5. ALL 16MM. BLUE STRIPE TO BE INSTALLED BELOW GRADE.

4. P.V.C. PIPING TO BE BURIED A MINIMUM 0F 12".

1/2 Gal / Day 1 Gal / Day 2 Gal / Day 5 Gal / Day 20 Gal / Day

TO EXISTING VEGETATION.

3. CONTRACTOR TO ROUTE ALL PIPING TO INSURE MINIMAL DISTURBANCE

2. CONNECTION FROM 16 MM. TO EMITTER TO BE MADE WITH, " SPAGHETTI TUBING".

EMITTERS TO ESTABLISH THE FOLLOWING FLOW RATES.

1 Gal Plant 3 Gal Plant 7 Gal Plant 15 Gal Plant 30 Gal Plant

1. CONTRACTOR TO INSTALL RAIN BIRD PRESSURE COMPENSATING

9. CREATE ONE ZONE FOR TREES ONLY, USE BUBBLERS THAT WILL PROVIDE REQUIRED FLOW.

10. CREATE ONE ZONE FOR SHRUBS AND GRASSES WITH NETAFIM OR SIMILAR PRODUCT.

11. CREATE ONE ZONE FOR SEA OATS WITH MICRO SPRAY HEAD.

POINT OF CONNECTION DETAIL

HUNTER PVG VALUE

Rain Bird ESP - HUNTER 3 STATION NODEc

1" SCHEDULE 40 PVC

IRRIGATION SCHEDULE

1" DRIP STUB UP

MAINLINE LOCATION IS SCHEMATIC, MAINLINE TO BE LOCATED ON PROPERTY.

16ml BUBBLER ZONE

HUNTER PCN - 20 BUBBLER

HUNTER PCN - 10 BUBBLER

CONNECT NETAFIM, .9GPH AT STUB UPS

CREATING A LOOP <250'

HUNTER MICRO SPRAY ZONE, PLACE TO IRRIGATE MOST EFFICIENTLY

HS-S-BT

LOCATE TIMER IN A MB-0811-G VALVE BOX

OR SIMILAR

c

6" SCHEDULE 40 PVC CONDUIT

UP

EXISTING VEGETATION SHALL

BE PRESERVED (SEE

PRESERVATION NOTE).

EXISTING VEGETATION SHALL

BE PRESERVED (SEE

PRESERVATION NOTE).

EXISTING VEGETATION SHALL

BE PRESERVED (SEE

PRESERVATION NOTE).

10' 20'5'0' 2'

SCALE 1" = 10' - 0"

AutoCAD SHX Text M

AutoCAD SHX Text

REGIONAL UTILITIES INSTALLED

AutoCAD SHX Text

DOUBLE CHECK BACKFLOW

AutoCAD SHX Text

PREVENTER

AutoCAD SHX Text

STRUCTURE

AutoCAD SHX Text

3/4" ISOLATION BALL VALVE

AutoCAD SHX Text

3/4" RPZ

AutoCAD SHX Text

TO IRRIG. SYSTEM

AutoCAD SHX Text

ROAD

AutoCAD SHX Text

3/4" SERVICE

AutoCAD SHX Text

BACKFLOW PREVENTER

AutoCAD SHX Text

WATER METER

Sheets and Views
GRAYTON RESTROOM LANDSCAPE-GRAYTON REST AREA LANDSCAPE
GRAYTON RESTROOM LANDSCAPE-GRAYTON REST AREA IRRIGATION

File details come from the government source that posted it. Updated .