Jefferson Maintenance Facility Floor Plan.pdf

PDF 153 KB Posted

Attached to
Construction Manager at Risk for Jefferson and Albia
Solicitation number
645-RFP-1728-2025
Issued by
Jasper County, Alburnett City, Iowa

About this file

This is a floor plan document for the Jefferson Maintenance Facility prepared by the Iowa Department of Transportation. The facility spans approximately 190 feet in length and 85 feet in width, containing 16 primary operational areas and numerous subdivided zones. The facility includes mechanics bays with trolley hoist bridges and rail systems, wash bays, a brine maker, storage areas for parts and supplies, office spaces for mechanics, locker rooms, break and training areas, restrooms, utility rooms, a communications closet, and a refrigerated storage area. The floor plan indicates specific slope specifications for drainage (ranging from 1/8" to 1/4" per foot) and includes an AED location marked at 23 feet from a reference point. Various sections are subdivided into lettered subsections (A through K in some areas), suggesting multiple functional zones within larger operational spaces.

The Jefferson Maintenance Facility floor plan serves as a supporting document for the Iowa Department of Transportation's Construction Manager at Risk (CMaR) solicitation (645-RFP-1728-2025) for new maintenance facilities in both Albia and Jefferson. Proposal submissions are due May 15, 2025, at 1:00 PM CDT, with pre-proposal virtual conferences scheduled for April 30, 2025. The facility plan provides prospective construction managers with detailed spatial and structural information necessary for developing comprehensive project approaches and cost estimates. Evaluation criteria emphasize firm history, project experience, team composition, and project approach, with cost treated as a secondary consideration. The procurement allows for separate awards at each location based on qualifications, and interested firms must submit three years of financial documentation, including financial statements and references, along with a proposed percentage fee for construction costs.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Refrigerator

STORAGE BAYS

WOMENS

RESTROOM

MENS RESTROOM

UTILITY ROOM

BREAK/TRAINING

ROOM

CORRIDOR

VESTIBULE

LOCKER ROOM

OFFICE

SUPPLY/PARTS

STORAGE

COMM CLOSET

UTILITY ROOM

PARTS STORAGE

MECHANICS

OFFICE

WASH BAYS

BRINE MAKER

MECHANICS

BAYS

115B

111A

116C

116B

116A

112B

114A

106E

106D

106B

106A

102C

102D

100A100B

102A

111B

112A

110F 110G 110H

111D 110E 110D 110C 110B

115A

102B

106C

114B

110J

1/4" SLOPE PER FT TO DRAIN

1/8" PER FT SLOPE TO DRAIN1/8" PER FT SLOPE TO DRAIN

AED

23' - 0"

111C

110A

110K

TROLLEY HOIST RAIL

TROLLEY HOIST RAIL

TROLLEY HOIST RAIL

TROLLEY HOIST RAIL

T R

O L L E

Y H

O

IS

T B

R

ID

G E

T R

O L L E

Y H

O

IS

T B

R

ID

G E

/4

32' - 0 15/16"

28' - 0 15/16"

26' - 8 9/16"

190' - 4 3/16"

85' - 7"

JEFFERSON MAINTENANCE FACILITY FLOOR PLAN

File details come from the government source that posted it. Updated .