Jefferson Maintenance Facility Floor Plan.pdf
PDF 153 KB Posted
- Solicitation number
- 645-RFP-1728-2025
- Issued by
- Jasper County, Alburnett City, Iowa
About this file
This is a floor plan document for the Jefferson Maintenance Facility prepared by the Iowa Department of Transportation. The facility spans approximately 190 feet in length and 85 feet in width, containing 16 primary operational areas and numerous subdivided zones. The facility includes mechanics bays with trolley hoist bridges and rail systems, wash bays, a brine maker, storage areas for parts and supplies, office spaces for mechanics, locker rooms, break and training areas, restrooms, utility rooms, a communications closet, and a refrigerated storage area. The floor plan indicates specific slope specifications for drainage (ranging from 1/8" to 1/4" per foot) and includes an AED location marked at 23 feet from a reference point. Various sections are subdivided into lettered subsections (A through K in some areas), suggesting multiple functional zones within larger operational spaces.
The Jefferson Maintenance Facility floor plan serves as a supporting document for the Iowa Department of Transportation's Construction Manager at Risk (CMaR) solicitation (645-RFP-1728-2025) for new maintenance facilities in both Albia and Jefferson. Proposal submissions are due May 15, 2025, at 1:00 PM CDT, with pre-proposal virtual conferences scheduled for April 30, 2025. The facility plan provides prospective construction managers with detailed spatial and structural information necessary for developing comprehensive project approaches and cost estimates. Evaluation criteria emphasize firm history, project experience, team composition, and project approach, with cost treated as a secondary consideration. The procurement allows for separate awards at each location based on qualifications, and interested firms must submit three years of financial documentation, including financial statements and references, along with a proposed percentage fee for construction costs.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Refrigerator
STORAGE BAYS
WOMENS
RESTROOM
MENS RESTROOM
UTILITY ROOM
BREAK/TRAINING
ROOM
CORRIDOR
VESTIBULE
LOCKER ROOM
OFFICE
SUPPLY/PARTS
STORAGE
COMM CLOSET
UTILITY ROOM
PARTS STORAGE
MECHANICS
OFFICE
WASH BAYS
BRINE MAKER
MECHANICS
BAYS
115B
111A
116C
116B
116A
112B
114A
106E
106D
106B
106A
102C
102D
100A100B
102A
111B
112A
110F 110G 110H
111D 110E 110D 110C 110B
115A
102B
106C
114B
110J
1/4" SLOPE PER FT TO DRAIN
1/8" PER FT SLOPE TO DRAIN1/8" PER FT SLOPE TO DRAIN
AED
23' - 0"
111C
110A
110K
TROLLEY HOIST RAIL
TROLLEY HOIST RAIL
TROLLEY HOIST RAIL
TROLLEY HOIST RAIL
T R
O L L E
Y H
O
IS
T B
R
ID
G E
T R
O L L E
Y H
O
IS
T B
R
ID
G E
/4
32' - 0 15/16"
28' - 0 15/16"
26' - 8 9/16"
190' - 4 3/16"
85' - 7"
JEFFERSON MAINTENANCE FACILITY FLOOR PLAN
File details come from the government source that posted it. Updated .