Albia - 70 Percent MEP Reference Dwgs Example.pdf
PDF 6 MB Posted
- Solicitation number
- 645-RFP-1728-2025
- Issued by
- Jasper County, Alburnett City, Iowa
About this file
Summary
This file is a comprehensive set of 70 percent schematic design documents for the Albia Iowa Department of Transportation (Iowa DOT) Maintenance Garage facility, prepared by Shive-Hattery architectural and engineering firm. The project includes detailed structural, mechanical, plumbing, fire protection, and electrical drawings for a new maintenance complex located at 1501 SC Street, Albia, Iowa 52531. The facility encompasses multiple functional areas including mechanics bays, storage bays, wash bays, office space, utility rooms, and supporting infrastructure, with construction planned across multiple levels and a garage roof design rated for 115 mph wind speeds. The schematic documents establish the design basis for subsequent construction phases and indicate that the project may be scaled to include additional storage bays and updated utilities based on site-specific conditions and geotechnical findings.
The drawings specify detailed material standards, equipment schedules, and installation requirements across all building systems. Structural elements include reinforced concrete foundations, precast concrete wall panels, steel framing with composite deck systems, and masonry construction requiring special inspections per building code. Mechanical systems incorporate radiant heating, make-up air units, energy recovery ventilation, and CO/NO2 monitoring for exhaust control. Electrical infrastructure includes a 400-amp main distribution panel with backup generator capability, comprehensive fire alarm and life safety systems, and lighting controls with occupancy sensors and daylight harvesting. Plumbing systems feature backflow prevention, compressed air distribution, and a sand-oil interceptor. All specifications reference current ASTM, ACI, AISC, and NEC standards, with PCI-certified precast fabricators and special inspection coordination required throughout construction.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
X X
X X
X X
X X
X X
X X
X
X X X X X X X X X X X X X X X X
X X
X X
X X
X X
X X
X
959961962
965965
A
B C D E F
A B C D E F
W
ES
TO
W
N P
AR
KW
AY
, S
U
IT
E
W
ES
T
D
ES
M O
IN
ES
, I A
5.
3.
S H
IV
E-
H
AT
TE
R
Y.
C
O M
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
IS
SU
ED
F
O R
IS
SU
E D
AT
E
FI
EL
D B
O O
K:
PR
O
JE
C
T N
U M
BE
R
Pr in te d: EX-1
EX
IS
TI
N
G C
O N
D
IT
IO
N
S M
AP
KA
L
KA
L
R
EV
IE
W
/1
0/
ID
O
T
AL
BI
A
M
AI
N
TE
N
AN
C E
G
AR
AG
E
IO
W
A D
EP
AR
TM
EN
T O
F
TR
AN
SP
O R
TA
TI
O N
S C
S T, A
LB
IA
, I
A
\\s h.
sh ive
-h at te ry
.c om
\D
AT
A\ Pr oj ec ts \2
4\
\D el ive ra bl es \D ra wi ng s\
1_ Ci vil \E xh ib its \2
4-
-1
EX
IS
TI
NG
C
O
ND
IT
IO
NS
M
AP
.d wg
/1 0/
:4
4:
P M
ALBIA - IOWA DOT MAINTENANCE SITE EXISTING CONDITIONS
(THIS IS SCHEMATIC ONLY - NOT FOR CONSTRUCTION)
1. ALL METAL DECK SHALL BE DESIGNED, MANUFACTURED, AND INSTALLED IN ACCORDANCE WITH
THE LATEST PROVISIONS OF THE STEEL DECK INSTITUTE - "DESIGN MANUAL FOR COMPOSITE
DECKS, FORM DECKS, ROOF DECKS AND CELLULAR METAL FLOOR DECK WITH ELECTRICAL
DISTRIBUTION" AND UNDERWRITER REQUIREMENTS (I.E. FACTORY MUTUAL).
2. STEEL DECK AND ACCESSORIES SHALL BE FABRICATED FROM STEEL SHEETS CONFORMING TO
THE FOLLOWING STANDARDS:
PAINTED STEEL ROOF DECK ASTM A1008, GR 33
GALVANIZED STEEL ROOF DECK ASTM A653, GR 33
COMPOSITE STEEL FLOOR DECK ASTM A653, GR 50 [40]
3. PROVIDE METAL DECK MANUFACTURED BY A MEMBER OF THE STEEL DECK INSTITUTE OF THE
TYPE AND GAUGE INDICATED ON THE DRAWINGS.
4. GALVANIZED STEEL ROOF, FLOOR AND COMPOSITE DECK SHALL BE SHEET MATERIAL
CONFORMING TO ASTM A924 WITH A MINIMUM G60 COATING.
5. MINIMUM DECK BEARING ON STEEL MEMBERS SHALL BE 1 1/2". INSTALL DECK WITH A MINIMUM
2" END LAPS CENTERED OVER SUPPORT MEMBERS. COMPOSITE FLOOR DECK ENDS SHALL NOT
BE LAPPED.
6. DECK MANUFACTURER SHALL PROVIDE ALL RIDGE AND VALLEY PLATES, FLOOR DECK FILLERS, AND COLUMN CLOSURES NECESSARY TO COMPLETE THE DECK INSTALLATION. ALL DECK AND
ACCESSORIES SHALL BE GALVANIZED, 20 GA. MINIMUM.
7. WHERE NOT INDICATED IN THE DRAWINGS, ATTACH ROOF DECK TO SUPPORTING STEEL
MEMBERS WITH EITHER PUDDLE WELDS OR POWDER ACTUATED FASTENERS:
A. (4) 5/8" DIAMETER PUDDLE WELDS PER 36 INCH WIDE SHEET (36/4 PATTERN). FASTEN
SIDELAPS CONDITIONS WITH #10 SELF DRILLING SCREWS, MINIMUM OF ONE SCREW AT
EACH MID SPAN OR AT 24" ON CENTER MAXIMUM . ATTACH DECK TO EDGES AT MEMBERS
PARALLEL TO CORRUGATIONS WITH 5/8" DIAMETER PUDDLE WELDS AT MINIMUM 6" ON
CENTER.
B. APPROVED EQUIVALENT POWDER ACTUATED FASTENERS THAT MEET THE SAME CAPACITY
VALUES AS WELDED CONNECTIONS.
8. WHERE NOT INDICATED IN THE DRAWINGS, ATTACH FLOOR DECK TO SUPPORTING STEEL
MEMBERS WITH PUDDLE WELDS.
A. (4) 5/8" DIAMETER PUDDLE WELDS PER 36 INCH WIDE SHEET (36/4 PATTERN). ATTACH DECK
TO EDGE ANGLES AND MEMBERS PARALLEL TO CORRUGATIONS WITH 5/8" DIAMETER
PUDDLE WELDS AT MINIMUM 12" ON CENTER. CONNECT DECK SIDE LAP WITH #10 TEK
SCREWS AT 1/2 THE SPAN OR 36" ON CENTER.
B. HEADED WELDED STUD INSTALLATION MAY BE SUBSTITUTED FOR WELDED DECK
FASTENING REQUIREMENTS.
9. DO NOT HANG ANY PIPING, DUCT WORK OR EQUIPMENT GREATER THAN 50LBS FROM STEEL
ROOF DECK.
10. FLOOR DECKING DEPTH AND GAGES SHOWN HAVE BEEN DESIGNED TO SUPPORT THE WEIGHT
OF WET CONCRETE PLUS A CONSTRUCTION LIVE LOAD OF 20 PSF WITHOUT INTERMEDIATE
SHORING BASED ON A MINIMUM THREE SPAN CONDITION. AREAS WHICH REQUIRE ONE OR TWO
SPAN CONDITIONS BASED ON THE SHOP DRAWING LAYOUT, SHALL BE INVESTIGATED BY THE
MANUFACTURER FOR DEFLECTION AND ALLOWABLE STRESSES. IF DEFLECTION EXCEEDS 1/180
THE SPAN OR THE ALLOWABLE STRESSES OF THE DECK THEN SHORING SHALL BE INDICATED
ON THE SHOP DRAWINGS FOR THOSE LOCATIONS.
11. AFTER DECK INSTALLATION, PREPARE AND REPAIR DAMAGED GALVANIZED COATINGS ON BOTH
SURFACES OF THE DECK WITH GALVANIZED REPAIR PAINT ACCORDING TO ASTM A780 AND
MANUFACTURER'S WRITTEN INSTRUCTIONS.
12. AFTER PAINTED DECK INSTALLATION, CLEAN RUST SPOTS, WELDS AND ABRADED SURFACES OF
PAINTED DECK. APPLY REPAIR PAINT OF SAME COLOR AND TYPE AS MANUFACTURER'S SHOP
PRIMED DECK.
13. VERIFY ALL OPENING SIZES AND LOCATIONS WITH THE APPROPRIATE TRADES. REINFORCE DECK OPENINGS FROM SIX (6) INCHES TO TWELVE (12) INCHES IN SIZE WITH L2x2x1/4 STEEL
ANGLES. PLACE FRAMING ANGLES PERPENDICULAR TO FLUTES, EXTEND A MINIMUM TWO (2)
FLUTES BEYOND EACH SIDE OF OPENING AND WELD TO DECK AT EACH FLUTE. REFER TO
TYPICAL DETAIL FOR LARGER OPENINGS.
STEEL DECK
1. CONRACTOR SHALL SUBMIT FOR REVIEW AND APPROVAL THE FOLLOWING SUBMITTALS FOR
EACH MATERIAL INDICATED BELOW.
2. CONCRETE REINFORCING
A. SUBMIT CONCRETE REINFORCEMENT SHOP DRAWINGS IN ACCORDANCE WITH ACI 315 FOR
APPROVAL.
a. DETAIL BARS IN ACCORDANCE WITH "ACI DETAILING MANUAL", PUBLICATION SP-66 AND
THE LATEST EDITION OF ACI 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE".
3. CAST-IN-PLACE CONCRETE
A. SUBMIT CONCRETE MIX DESIGNS FOR EACH APPLICATION LOCATION INDICATED IN THE
DRAWINGS.
B. SUBMIT SHOP DRAWING OF EMBEDDED STEEL ELEMENTS AND CONNECTIONS.
4. PRECAST STRUCTURAL CONCRETE
A. PROVIDE PRECAST STRUCTURAL CONCRETE SHOP DRAWINGS WHICH INCLUDE THE
FOLLOWING:
a. PLANS INDICATING MEMBER SIZES, LOCATIONS, DIMENSIONS, OPENING LOCATIONS
SUPPORT CONDITIONS AND REINFORCEMENT.
b. DETAIL CONNECTIONS AT MEMBER ENDS AND ADJACENT CONSTRUCTION.
c. TYPE, SIZE AND LENGTH OF WELDED CONNECTIONS.
d. LOCATIONS AND DETAILS OF ANCHORAGE DEVICES TO BE EMBEDDED IN OR ATTACHED
TO STRUCTURE OR OTHER CONSTRUCTION.
e. INDICATE LOCATION, DIMENSIONS AND DETAILS OF CORNER UNITS AND SPECIAL
SHAPES AND JOINTS.
f. PROVIDE ENGINEERING DESIGN ANALYSIS AND CALCULATIONS DATA SIGNED AND
SEALED BY THE QUALIFIED PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE
THE PROJECT IS LOCATED.
5. CONCRETE UNIT MASONRY
A. SUBMIT CONCRETE MASONRY UNIT PRODUCT DATA, INDICATING COMPRESSIVE STRENGTH
OF UNITS, MORTAR AND GROUT.
B. SUBMIT SHOP DRAWINGS WITH PLANS AND ELEVATIONS INDICATING CONTROL JOINTS AND
STEEL REINFORCING TO BE INSTALLED IN WALL. INDICATE SIZE, LOCATIONS, BAR LENGTHS
AND SPLICING LENGTHS.
6. STRUCTURAL STEEL
A. STRUCTURAL STEEL SHOP DRAWINGS SHOWING COMPLETE DIMENSIONS, DETAILS, SIZES,
AND GRADES OF STEEL MEMBERS AND CONNECTIONS, SIZE, TYPE, AND NUMBER OF
WELDS SHALL BE PREPARED AND SUBMITTED FOR APPROVAL PRIOR TO FABRICATION OF
STEEL COMPONENTS.
B. STRUCTURAL STEEL SHOP DRAWINGS SHALL BE DETAILED IN COMPLIANCE WITH THE AISC
"DETAILING FOR STEEL CONSTRUCTION". STRUCTURAL STEEL SHALL BE FABRICATED AND
ERECTED IN COMPLIANCE WITH AISC 360 - "SPECIFICATION FOR STRUCTURAL STEEL
BUILDINGS."
C. CONNECTION DESIGN: SUBMIT DESIGN AND DETAILS OF STRUCTURAL CONNECTIONS
REQUIRED BY THE CONTRACT DOCUMENTS TO BE SELECTED AND COMPLETED BY THE
STRUCTURAL STEEL FABRICATOR, INCLUDING COMPREHENSIVE ENGINEERING ANALYSIS
BY A QUALIFIED REGISTERED STRUCTURAL ENGINEER LICENSED IN THE STATE WHERE
THE PROJECT IS LOCATED. CONNECTION SHALL BE DESIGNED AND DETAILED TO
WITHSTAND THE FORCES AND DESIGN CRITERIA INDICATED ON DRAWINGS.
7. STEEL JOISTS
A. SUBMIT BAR JOIST SHOP DRAWING WITH PLANS INDICATING LAYOUT, SIZE DESIGNATIONS, SPAN LENGTHS, SPACINGS, BRIDGING REQUIREMENTS AND CONNECTION CONDITIONS.
B. SUBMIT COMPREHENSIVE ENGINEERING DESIGN ANALYSIS OF SPECIAL JOISTS SIGNED
AND SEALED BY THE QUALIFIED PREOFESSIONAL ENGINEER.
8. STEEL DECKING
A. SUBMIT STEEL DECK SHOP DRAWING INDICATING PLANS, SIZES, LENGTHS, SPACINGS,
BEARING CONDITIONS AND CONNECTION REQUIREMENTS.
9. COLD FORMED STEEL FRAMING
A. PROVIDE COLD FORMED STEEL FRAMING SHOP DRAWINGS WHICH INCLUDE THE
FOLLOWING:
a. PLANS INDICATING MEMBER SIZES, LOCATIONS, DIMENSIONS, OPENING LOCATIONS
SUPPORT CONDITIONS AND WEB REINFORCEMENT.
b. DETAIL CONNECTIONS AT MEMBER ENDS AND ADJACENT CONSTRUCTION.
c. TYPE, SIZE AND LENGTH OF WELDED CONNECTIONS.
d. LOCATIONS AND DETAILS OF ANCHORAGE DEVICES TO BE EMBEDDED IN OR ATTACHED
TO STRUCTURE OR OTHER CONSTRUCTION.
e. PROVIDE ENGINEERING DESIGN ANALYSIS AND CALCULATIONS DATA SIGNED AND
SEALED BY THE QUALIFIED PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE
THE PROJECT IS LOCATED.
SUBMITTALS
1. DESIGN STRUCTURAL PRECAST TO COMPLY WITH ACI 318 AND PCI MNL 120, "PCI DESIGN
HANDBOOK - PRECAST AND PRESTRESSED CONCRETE." PRECAST STRUCTURAL CONCRETE
COMPONENTS SHALL BE DESIGNED BY THE PRECAST MANUFACTURER'S QUALIFIED
STRUCTURAL ENGINEER LICENSED IN THE STATE WHERE THE PROJECT IS LOCATIONS.
PROVIDE COMPREHENSIVE ENGINEERING ANALYSIS AND DESIGN USING PERFORMANCE
REQUIREMENTS AND DESIGN CRITERIA INDICATED IN THE DRAWINGS AND SPECIFICATIONS.
2. PRECAST STRUCTURAL CONCRETE MATERIAL STANDARDS:
A. MINIMUM 28 DAY COMPRESSIVE STRENGTH: 5,000 PSI
B. REINFORCING BARS: ASTM A615 60,000 PSI
C. LOW-ALLOY WELDABLE REINFORCING BARS: ASTM A706 60,000 PSI
D. PRESTRESSING STEEL WIRE, MIN ULTIMATE STRENGTH ASTM A416 270,000 PSI
3. PRECAST MANUFACTURER SHALL BE A PCI CERTIFIED PLANT. PRECAST STRUCTURAL
CONCRETE COMPONENTS SHALL BE FABRICATED TO COMPLY WITH PCI MNL 116, "MANUAL
FOR QUALITY CONTROL FOR PLANTS AND PRODUCTION OF STRUCTURAL PRECAST CONCRETE
PRODUCTS."
4. DESIGN PRECAST STRUCTURAL CONCRETE FRAMING SYSTEM AND CONNECTIONS TO
MAINTAIN CLEARANCES AT OPENINGS, TO ALLOW FOR FABRICATION AND CONSTRUCTION
TOLERANCES, TO ACCOMMODATE LIVE LOAD DEFLECTIONS, SHRINKAGE, CREEP AND OTHER
BUILDING MOVEMENTS. MAINTAIN DEFLECTION LIMITS OF ACI 318
5. FABRICATOR SHALL BE A PCI CERTIFIED PLANT UNDER GROUP C and CA.C3(A) - PRESTRESSED
STRAIGHT STRAND STRUCTURAL MEMBERS
6. PRECAST INSTALLER/ERECTOR SHALL BE PCI CERTIFIED (CATEGORY S2 - COMPLEX) TO ERECT
STRUCTURAL SYSTEMS.
7. FURNISH ALL LOOSE CONNECTION HARDWARE AND ANCHORAGE ITEMS TO BE EMBEDDED IN
OR ATTACHED TO OTHER CONSTRUCTION AHEAD OF THOSE CONSTRUCTION SEQUENCES.
PROVIDE LOCATION, SETTING DIAGRAMS, TEMPLATES, AND INSTALLATION INSTRUCTIONS.
8. ALL PRECAST BEARING CONDITIONS SHALL USE A BEARING PAD AS RECOMMENDED BY THE
PRECAST MANUFACTURER FOR THE APPLICATION. STEEL SHIMS ARE NOT ALLOWED.
9. CAST-IN ANCHORS, INSERTS, PLATES ANGLES OR OTHER ANCHORAGE HARDWARE WITH
SUFFICIENT ANCHORAGE AND EMBEDMENT TO COMPLY WITH DESIGN REQUIREMENTS.
10. CAST-IN OPENINGS LARGER THAN 100 SQUARE INCHES (10"x10"). PROVIDE FIELD CUT OPENING
SIZES AND LOCATION ON THE SHOP DRAWING SUBMITTAL FOR PRECAST MANUFACTURERS
REVIEW AND APPROVAL.
11. DO NOT INSTALL PRECAST CONCRETE UNITS UNTIL SUPPORTING STRUCTURE IS COMPLETE
AND STRUCTURALLY READY TO RECEIVE LOADS FROM PRECAST. CAST-IN-PLACE CONCRETE
SHALL HAVE ACHIEVED SPECIFIED DESIGN STRENGTH WITH TESTING CONFIRMATION
PERFORMED.
12. ERECT PRECAST STRUCTURAL CONCRETE LEVEL, PLUMB, AND SQUARE WITHIN ACI
TOLERANCES. PROVIDE TEMPORARY FRAMING, SHORING, AND BRACING AS REQUIRED TO
MAINTAIN POSITION, STABILITY AND ALIGNMENT OF UNITS UNTIL PERMANENT CONNECTIONS
ARE COMPLETED.
13. CLEAN EXPOSED SURFACES OF PRECAST CONCRETE UNITS AFTER ERECTION AND
COMPLETION OF THE JOINT GROUTING. REMOVE WELD SLAG, STAINS, DIRT AND OTHER
DELETERIOUS MATERIAL.
14. REFER TO ARCHITECTURAL DRAWINGS FOR EXPOSED SURFACE FINISHES, TEXTURES,
REVEALS, ETC.
PRECAST STRUCTURAL CONCRETE
1. CONCRETE MASONRY UNIT STANDARDS AND COMPRESSIVE STRENGTHS:
DESIGN ASSEMBLY STRENGTH, F'm , BY UNIT STRENGTH METHOD 2500 PSI
CONCRETE MASONRY UNITS (NORMAL WEIGHT) ASTM C90 3250 PSI
MASONRY GROUT ASTM C476 2500 PSI
MASONRY MORTAR, TYPE S ASTM C270 1800 PSI
REINFORCING FOR MASONRY ASTM A615 Fy = 60 KSI
PLATE AND BENT BAR ANCHORS ASTM A36
WIRE MESH TIES ASTM A185
JOINT REINFORCEMENT, LADDER TYPE, 1.7(9GA) ASTM A1064
ANCHOR RODS FOR MASONRY ASTM A307
2. THE LOAD BEARING CONCRETE MASONRY WALLS FOR THIS PROJECT WERE DESIGNED TO
SPAN VERTICALLY AND BE BRACED BY THE ROOF AND FLOOR FRAMING ELEMENTS OF THE
STRUCTURE. DURING CONSTRUCTION THE MASONRY CONTRACTOR SHALL PROVIDE LATERAL
BRACING UNTIL THE ROOF STRUCTURE IS INSTALLED AS RECOMMENDED BY ACI 530 AND THE
LATEST REVISION OF "STANDARD PRACTICE FOR BRACING MASONRY WALLS UNDER
CONSTRUCTION", PREPARED BY THE COUNCIL FOR MASONRY WALL BRACING. THIS BRACING IS
TO PREVENT UNNECESSARY STRESS OR DAMAGE TO THE MASONRY WALLS FROM LATERAL
LOADS, WHICH CAN OCCUR WHILE THE WALLS ARE NOT PROPERLY BRACED BY THE ROOF AND
FLOOR STRUCTURE.
3. SPLICE REINFORCING USING CONTACT LAPS TO THE LENGTHS INDICATED BELOW:
NP = NOT PERMITTED
NOTES TO SPECIFIER:
BASED ON 100% ALLOWABLE TENSILE STRESS IN REINFORCING (24,000 PSI)
LAP SPLICE CAN BE REDUCED (DIV BY 1.5) IF STRESS IS LESS THAN 80%
BARS GREATER THAN #9 ARE REQUIRED TO BE MECHANICALLY SPLICED
4. MASONRY MATERIALS AND CONSTRUCTION SHALL COMPLY WITH THE REQUIREMENTS OF
“SPECIFICATION FOR MASONRY STRUCTURES AND RELATED COMMENTARIES (ACI 530/ASCE
6/TM 602) PUBLISHED BY AMERICAN CONCRETE INSTITUTE, EXCEPT WHERE REQUIREMENTS
ARE EXCEEDED BY THESE CONTRACT DOCUMENTS.
5. THOROUGHLY MIX MORTAR AND GROUT INGREDIENTS IN ACCORDANCE WITH THE
REFERENCED ASTM ABOVE IN QUANTITIES NEEDED FOR IMMEDIATE USE. DO NOT USE ANTI-
FREEZE COMPOUNDS TO LOWER THE FREEZE POINT.
6. ALL LOAD BEARING MASONRY WALLS SHALL BE HAVE FULL MORTAR BED, HEAD AND COLLAR
JOINTS. LAY HOLLOW MASONRY UNITS WITH FACE SHELL BEDDING ON HEAD AND BED JOINTS.
7. HORIZONTAL JOINT REINFORCEMENT: ALL LOAD BEARING MASONRY WALLS SHALL BE
CONSTRUCTED WITH LADDER TYPE JOINT REINFORCEMENT AS FOLLOWS:
A. SPACED AT A MAXIMUM OF 16" ON CENTER IN WALL CONSTRUCTION.
B. LAP JOINT REINFORCEMENT ENDS MINIMUM 6 INCHES.
C. PLACE HORIZONTAL JOINT REINFORCEMENT ONE ROW ABOVE AND ONE ROW BELOW ALL
WALL OPENINGS.
D. PLACE CONTINUOUS JOINT REINFORCEMENT IN FIRST JOINT BELOW THE TOP OF THE WALL.
E. DO NOT CONTINUE HORIZONTAL JOINT REINFORCEMENT ACROSS CONTROL OR EXPANSION
JOINTS.
8. ALL LOAD BEARING REINFORCED UNIT MASONRY WALLS SHALL HAVE (1) #5 BAR VERTICALLY IN
GROUTED CELL AT ALL CORNERS, ENDS OF WALLS, WALL INTERSECTIONS, AND IMMEDIATELY
ADJACENT TO EACH SIDE OF CONTROL JOINTS AND WALL OPENINGS.
9. CONCRETE MASONRY UNIT CORES SHALL BE PLACED WITH CELLS IN VERTICAL ALIGNMENT. ALL
CORES CONTAINING REINFORCEMENT AND ANCHORS SHALL BE FILLED SOLID WITH GROUT.
GROUT ALL CELLS TO RECEIVE ANCHORS.
10. PROVIDE A MINIMUM OF 1/2" OF GROUT BETWEEN THE MAIN REINFORCING AND THE MASONRY
UNITS. ALL VERTICAL REINFORCEMENT SHALL BE CENTERED IN THE WALL UNLESS NOTED
OTHERWISE.
11. ALL MASONRY WALLS SHALL HAVE VERTICAL CONTROL JOINTS AT A MAXIMUM SPACING OF 25
FEET AS FOLLOWS:
A. COORDINATE CONTROL JOINTS WITH LOCATIONS INDICATED ON ARCHITECTURAL
DRAWINGS.
B. CONTROL JOINTS SHALL NOT INTERFERE WITH BEAMS, JOISTS, OR LINTEL BEARING.
C. PROVIDE PREFORMED EXTRUDED RUBBER CONTROL JOINT DESIGNED FOR MASONRY
WALLS CONFORMING TO ASTM D2000 2AA-805.
D. SEAL JOINT WITH SINGLE COMPONENT ELASTERMERIC POLYURETHANE SEALANT. COLOR
TO MATCH MORTAR JOINTS.
12. DOWELS IN FOOTINGS SHALL BE PLACED TO ALIGN WITH CORES CONTAINING REINFORCING
STEEL. COORDINATE PLACEMENT BEFORE CONSTRUCTION OF FOOTING BEGINS.
13. GROUT SOLID ALL CMU CORES BELOW ADJACENT GRADE OR BELOW SLAB ON GRADE
CONSTRUCTION.
14. DURING CONSTRUCTION OF WALLS, COVER TOPS OF WALLS, PARTIALLY COMPLETED MASONRY
AND ANY OPEN WALL CAVITIES AT SILLS OR HEADERS WITH WATERPROOF SHEETING AT THE
END OF EACH DAY'S WORK.
15. MASONRY WALL CONSTRUCTION TOLERANCES
A. MAXIMUM VARIATION FROM UNIT TO UNIT: 1/16"
B. MAXIMUM VARIATION FROM PLANE OF WALL: 1/4"
C. MAXIMUM VARIATION FROM PLUMB: 1/4"
D. MAXIMUM VARIATION FROM LEVEL COURSING: 1/8"
E. MAXIMUM VARIATION OF JOINT THICKNESS: 1/8"
F. MAXIMUM VARIATION FROM CROSS SECTIONAL THICKNESS OF WALL: 1/4"
16. REINFORCE ALL NON-LOAD BEARING MASONRY WALLS (SHOWN ON ARCHITECTURAL
DRAWINGS) WITH #5 BARS AT XX" OC UNLESS NOTED OTHERWISE.
17. BEAM BEARING CONDITIONS: FILL BLOCK CELLS SOLID WITH GROUT A DISTANCE OF 24"
BENEATH AND 12" EACH SIDE OF BEAM REACTIONS OR OTHER CONCENTRATED LOADS IF NOT
OTHERWISE REINFORCED. ALL BEAM AND JOIST POCKETS SHALL BE GROUTED SOLID OR
FILLED WITH CONCRETE MASONRY UNITS AFTER STEEL ERECTION IS COMPLETE.
REINFORCED UNIT MASONRY
BAR SIZE
#3
#4
#5
#6
#7
#8
#9
6" CMU
27"
36"
45"
54"
NP
NP
NP
8" CMU
27"
36"
45"
54"
63"
113"
NP
10" CMU
27"
36"
45"
54"
63"
72"
82"
12" CMU
27"
36"
45"
54"
63"
72"
82"
MINIMUM LAP SPLICE LENGTH
1. PROVIDE LINTELS ABOVE ALL WALL OPENINGS AND RECESSES GREATER THAN 12" WIDE AS
INDICATED IN THE PLANS AND LINTEL SCHEDULE.
2. OPENINGS NOT IDENTIFIED ON THE DOCUMENTS SHALL BE CONSTRUCTED IN A SIMILAR
MANNER TO THE SCHEDULED LOCATIONS THAT MATCH SPAN AND LOAD CONDITIONS. CONTACT
STRUCTURAL ENGINEER FOR CONFIRMATION.
3. LINTELS FOR 8" WIDE CMU NON-LOAD BEARING MASONRY PARTITION WALLS SHALL HAVE
LINTELS IN ACCORDANCE WITH THE FOLLOWING SCHEDULE:
ALL CMU BOND BEAM LINTELS SHALL HAVE A MINIMUM (2) #5 BARS PLACED 3" FROM THE
BOTTOM OF THE BLOCK AND GROUTED SOLID.
ALL STEEL ANGLE LINTELS ARE LONG LEG BACK TO BACK AND STITCH WELDED TOGETHER
TOP AND BOTTOM 3" LONG AT 12" ON CENTER MINIMUM.
4. ALL BOND BEAM LINTELS SHALL BE CONSTRUCTED USING BOND BEAM UNITS.
5. WALL OPENING JAMBS SHALL BE GROUTED SOLID FULL HEIGHT BELOW THE WIDTH OF THE
LINTEL BEARING, UNLESS NOTED OTHERWISE.
6. ALL LINTELS SHALL HAVE A MINIMUM OF 8" END BEARING, UNLESS NOTED OTHERWISE.
7. ALL STEEL LINTEL ASSEMBLIES IN EXTERIOR WALL CONSTRUCTION SHALL BE HOT-DIP
GALVANIZED PER ASTM A123, UNLESS NOTED OTHERWISE.
8. BEARING PLATES NOT REQUIRED FOR STEEL LINTELS, UNLESS NOTED OTHERWISE.
REINFORCED UNIT MASONRY - LINTELS
OPENING WIDTH MASONRY OPTION STEEL OPTION
1'-0 TO 2'-0"
>2'-0" TO 4'-0"
>4'-0" TO 6'-0"
>6'-0" TO 8'-0"
8" DEEP BOND BEAM 5/16"x7"PLATE
(2)L3 1/2x3 1/2x1/4
(2)L4x3 1/2x5/16(LLV)
(2)L5x3 1/2x5/16(LLV)
8" DEEP BOND BEAM
8" DEEP BOND BEAM
16" DEEP BOND BEAM
BA D E
FC G
P R
E L
IM
IN
A R
Y
N O
T F
O R
C
N
S T
R U
C T
IO
N
Io w a
I lli n o is
I n d ia n a
N e b ra s k a
D
A W
N
A P
P R
O V
E D
IS
S
U E
D F
O R
D A
T E
F
IE
L D
B O
O K
P R
O J E
C T
N O
H
P ri n te d
E n te r O ff ic e N u m b e r in G lo b a l P a ra m e te rs P h o n e w w w
.s h iv e -h a tt e ry
.c o m
BA D E FC G H
Autodesk Revit 2020
J E
F F
E R
E S
O N
M A
IN
T
E N
A N
C E
F A
C
IL
IT
Y
IO
W
A D
E P
T
O F
T R
A N
S P
O R
T A
T
IO
N
E n te r a d d re s s h e re
S001
S T
R U
C T
U R
A L
G E
N E
R A
L
IN
F O
R M
A T
IO
N
S
P E
C
IA
L
IN
S P
E C
T
IO
N S
D O
C U
M E
N T
S
C R
M
J P
L
-0
-2
7. The contractor is responsible for testing services that are required for material submittals and that not part of the special inspections program (e.g. aggregate tests, concrete mix designs, testing of controlled fill, materials, etc.).
6. The special inspection and quality assurance program does not relieve the contractor of his or her responsibility to perform quality control.
5. When deficiencies are identified, the contractor must take corrective actions to comply with the contract documents or remedy the deficiencies as directed by the registered design professional.
4. The contractor must cooperate with the inspections and testing agencies. Safe access must be provided to all inspection and test to be performed. This may require the contractor to provide scaffolding, ladders or lifts.
3. The contractor is responsible for scheduling inspections and tests. Sufficient notice and lead time must be allowed for the inspection and testing to be performed without impending construction operations.
2. Pre-construction meeting is to be conducted by the contractor with meeting minutes to be taken and distributed to all members attending. Meeting minutes to include a sign-in sheet for all parties.
1. The Contractor is responsible for scheduling a pre-construction meeting (scheduled at least 5 business days before start of construction). Meeting should include all responsible parties (A/E, SI's, Field Inspector). Meeting is for entire project, not phase of work.
CONTRACTOR'S RESPONSIBILITY REGARDING INSPECTIONS
6. Each Contractor responsible for the construction or fabrication of a system or component described above must submit a Statement of Responsibility.
I. Foundation design: Cast in place reinforced concrete on aggregate piers.
H. Critical support systems and connections and debris impact protection of the components and connections:
All critical systems are within shelter enclosure.
G. Corrosion resistance or protection of exposed metal connectors providing load path continuity: NA
F. Wall cladding and wall cladding connections: NA
E. Main windforce-resisting system connections to the foundation: Field welded steel embeds between precast concrete walls and concrete foundations.
D. Main windforce-resisting systems: Precast concrete shear walls.
C. Roof diaphragm systems, including connectors, drag struts and boundary elements: Reinforced concrete topping slab composite with double tee for roof diaphragm with diaphragm chord reinforcing.
B. Wall connections to roof diaphragm and framing: Steel framing to precast wall panel.
A. Roof cladding, soffits, and roof framing connection: Roof vapor retarder, insulation system, cover board and membrane. Field weld deck attachment to steel beams. See item "B" for beam connection to walls.
5. Description of Wind Force-Resisting components subject to Special Inspection of Wind Resistance:
SEE SPECIAL INSPECTION
CHARTS THIS SHEET
4. Description of main Wind Force-Resisting System subject to Special Inspection for Wind Resistance:
PRECAST SHEAR WALLS
3. Statement for Special Inspection for Wind Resistance Required (Y/N): Y
2. Wind Exposure Category: C
1. Nominal Design Wind Speed, Vasd = 115
Quality Assurance Plan for Wind Requirements:
2. Statement of Special Inspections for Seismic Resistance required (Y/N): N
1. Seismic Design Category: B
Quality Assurance for Seismic Resistance:
QUALITY ASSURANCE PLAN
EDI-EIFS EIFS Third Party Inspector
Exterior Design Institute (EDI) Certification
NICET-GET Geotechnical Engineering Technician - Level I, II, III & IV
NICET-ST Soils Technician - Levels I, II, III & IV
NICET-CT Concrete Technician - Levels I, II, III, & IV
National Institute of Certification in Engineering Technologies (NICET)
ICC-PCSI Prestressed Concrete Special Inspector
ICC-SWSI Structural Steel and Welding Special Inspector
ICC-RCSI Reinforced Concrete Special Inspector
ICC-SFSI Spray-Applied Fireproofing Special Inspector
ICC-SMSI Structural Masonry Special Inspector
International Code Council (ICC) Certification
ASNT Non-Destructive Testing Technician - Level II or III
American Society of Non-Destructive Testing (ASNT) Inspection
AWS/AISC-SSI Certified Structural Steel Inspector
AWS-CWI Certified Welding Inspector
American Welding Society (AWS) Certification
ACI-STT Strength Testing Technician
ACI-LTT Laboratory Testing Technician - Grade 1 & 2
ACI-CCI Concrete Construction Inspector
ACI-CFTT Concrete Field Testing Technician - Grade 1
American Concrete Institute (ACI) Certification
EIT Engineer-In-Training - A graduate engineer who has passed the Fundaments of Engineering examination
PE/GE Geotechnical Engineer - A licensed PE specializing in soil mechanics and foundations
PE/SE Structural Engineer - A licensed SE or PE specializing in the design of building structure
When the Registered Design Professional in Responsible Charge deems it appropriate that the individual performing a stipulated test or inspection have a specific certification or license as indicated below, such designations shall appear below the Agent on the Schedule.
Key for Minimum Qualifications of Inspection Agents:
The qualifications of all personnel performing Special Inspection and testing activities are subject to the approval of the Building Official. The credentials of all Inspectors and testing technicians shall be provided if requested.
QUALIFICATIONS OF INSPECTORS AND TESTING TECHNICIANS
Interim reports shall be submitted to the Building Official and the Registered Design Professional in Responsible Charge. A Final Report of Special Inspections documenting completion of all required Special Inspections, testing and corrections of any discrepancies noted in the inspections shall be submitted prior to issuance of a Certificate of Use and Occupancy. Job site safety and means and methods of construction are solely the responsibility of the Contractor.
The Special Inspection Coordinator shall keep records of all inspections and shall furnish inspection reports to the Building Official and the Registered Design Professional in Responsible Charge. Discovered discrepancies shall be brought to the immediate attention of the Contractor for correction. If such discrepancies are not corrected, the discrepancies shall be brought to the attention of the Building Official and the Registered Design Professional in Responsible Charge. The Special Inspection program does not relieve the Contractor of his or her responsibilities.
[ ] Architectural [ ] Other
[X] Structural [ ] Mechanical / Electrical / Plumbing
This Statement of Special Inspections is submitted as a condition for permit issuance in accordance with the Special Inspection and Structural Testing requirements of the Building Code. It includes a schedule of Special Inspection services applicable to the structural components of this project. If applicable, it includes Requirements for Seismic Resistance and/or Requirements for Wind Resistance. This Statement of Special Inspections Encompasses the following disciplines:
STATEMENT OF SPECIAL INSPECTIONS
11. PERFORM FLOOR FLATNESS AND/OR LEVELNESS
TESTING (ASTM E1155) FOR ALL SLAB-ON-GRADE
AND ELEVATED SLAB PER SPECIFICATION.
FIELD INSPECTION
PERIODIC AT ALL
BOLTED
CONNECTIONS
ACI-CCI,
ICC-RCSI
10. CERTIFY IN-SITU CONCRETE STRENGTH, PRIOR
TO STRESSING OF TENDONS IN
POST-TENSIONED CONCRETE AND PRIOR TO
REMOVAL OF SHORES AND FORMS FROM BEAMS
AND STRUCTURAL SLAB.
FIELD TESTING AND REVIEW
OF LABORATORY REPORTS
PERIODIC
9. INSPECTION OF FORMWORK FOR SHAPE, LINES,
LOCATION, AND DIMENSIONS FIELD INSPECTION PERIODIC
ACI-CCI,
ICC-RCSI
8. INSPECTION OF MAINTENANCE OF SPECIFIED
CURING TEMPERATURE AND TECHNIQUES FIELD INSPECTION PERIODIC
ACI-CCI,
ICC-RCSI
7. INSPECT PLACEMENT OF CONCRETE AND
SHOTCRETE. VERIFY THAT CONCRETE
CONVEYANCE AND DEPOSITING AVOIDS
SEGREGATION OR CONTAMINATION. VERIFY
THAT CONCRETE IS PROPERLY CONSOLIDADTED.
FIELD INSPECTION CONTINUOUS
ACI-CCI,
ICC-RCSI
6. TEST CONCRETE COMPRESSION STRENGTH
(ASTM C31 & C39), SLUMP (ASTM C143),
AIR-CONTENT (ASTM C231 OR C173) AND
TEMPERATURE (ASTM C1064)
FIELD INSPECTION CONTINUOUS
ACI-CFTT,
ACI-STT
5. REVIEW CONCRETE BATCH TICKETS AND VERIFY
COMPLIANCE WITH APPROVED MIX DESIGN.
VERIFY THAT WATER ADDED AT THE SITE DOES
NOT EXCEED THAT ALLOWED BY THE MIX DESIGN
FIELD INSPECTION PERIODIC
ACI-CCI,
ICC-RCSI
4. INSPECTION OF ANCHORS AND REINFORCING
STEEL POST-INSTALLED IN HARDENED
CONCRETE: PER RESEARCH REPORTS
INCLUDING VERIFICATION OF ANCHOR TYPE,
ANCHOR DIMENSIONS, HOLE DIMENSIONS, HOLE
CLEANING PROCEDURES, ANCHOR SPACING,
EDGE DISTANCES, CONCRETE MINIMUM
THICKNESS, ANCHOR EMBEDMENT, AND
TIGHTENING TORQUE.
FIELD INSPECTION
CONTINUOUS FOR
HORIZONTAL OR
UPWARDLY INCLINED
ORIENTATIONS TO
RESIST SUSTAINED
TENSION LOADS.
PERIODIC FOR ALL
OTHER ACHORS
ACI-CCI,
ICC-RCSI
3. INSPECT SIZE, POSITIONING, AND EMBEDMENT
OF ANCHOR RODS. INSPECT CONCRETE
PLACEMENTS AND CONSOLIDATION AROUND
ANCHORS
FIELD INSPECTION PERIODIC
C. ALL OTHER WELDS CONTINUOUS
B. INSPECT SINGLE PASS FILLET WELDS < 5/16" PERIODIC
A. VERIFICATION OF WELDABILITY OF STEEL
OTHER THAN ASTM A706
PERIODIC
2. REINFORCING STEEL WELDING FIELD INSPECTION
1. INSPECT SIZE, SPACING, COVER, POSITIONING
AND GRADE OF REINFORCING STEEL AND
PRESTRESSING STEEL. VERIFY THAT
REINFORCING BARS ARE FREE OF FORM OIL OR
OTHER DELETERIOUS MATERIALS. INSPECT BAR
LAPS AND MECHANICAL SPLICES. VERIFY THAT
BARS ARE ADEQUATELY TIED AND SUPPORTED
OF CHAIRS OR BOLSTERS.
FIELD INSPECTION PERIODIC
ACI-CCI,
ICC-RCSI
CONCRETE CONSTRUCTION SERVICE EXTENT AGENT
11. OPEN WEB STEEL JOIST: INSPECT
INSTALLATION, FIELD WELDING, FIELD BOLTING,
AND BRIDGING OF JOIST IS IN CONFORMANCE
WITH APPROVED SUBMITTAL
FIELD INSPECTION PERIODIC
9. CONNECTION OF COLD-FORMED STEEL DECK TO
SUPPORTING STRUCTURE: INSPECT WELDING
AND SIDE-LAP FASTENING OF METAL ROOF AND
FLOOR DECK IS IN CONFORMANCE WITH
APPROVED SUBMITTAL.
FIELD INSPECTION PERIODIC
8. MATERIAL VERIFICATION OF COLD-FORMED
STEEL DECK: IDENTIFICATION MARKINGS
FIELD INSPECTION PERIODIC
7. INSPECTION OF STEEL ELEMENTS OF
COMPOSITE CONSTRUCTION PRIOR TO
CONCRETE PLACEMENT: INSPECT SIZE,
NUMBER, POSITIONING, AND WELDING OF SHEAR
CONNECTORS. INSPECT STUDS FOR FULL 360
DEGREE FLASH. PING TEST ALL SHEAR
CONNECTORS WITH A 3 LB HAMMER. BEND TEST
ALL QUESTIONABLE STUDS TO 15 DEGREES
FIELD INSPECTION AND
TESTING
PERIODIC
C. INSPECTION TASKS AFTER BOLTING
(PERFORM TASKS FOR EACH BOLTED
CONNECTION IN ACCORDANCE WITH QA
TASKS LISTED IN AISC 360, TABLE N5.6-3
FIELD INSPECTION
PERIODIC AT ALL
BOLTED
CONNECTIONS
2) SNUG-TIGHT JOINTS PERIODIC
e. CALIBRATED WRENCH CONTINUOUS
d. TURN-OF-NUT WITHOUT MATCHING
MARKINGS CONTINUOUS
c. TWIST-OFF TYPE TENSION CONTROL
BOLT CONTINUOUS
b. DIRECT TENSION INDICATOR CONTINUOUS
a. TURN-OF-NUT WITH MATCHING
MARKINGS CONTINUOUS
1) PRE-TENSIONED AND SLIP-CRITICAL
JOINTS
B. INSPECTION TASKS DURING BOLTING
(OBSERVE THE QA TASKS LISTED IN AISC 360,
TABLE N5.6-2)
FIELD INSPECTION
PERIODIC AT ALL
BOLTED
CONNECTIONS
A. INSPECTION TASKS PRIOR TO BOLTING
(OBSERVE OR PERFORM TASKS FOR EACH
BOLTED CONNECTION, IN ACCORDANCE WITH
QA TASKS LISTED IN AISC 360, TABLE N5.6-1)
FIELD INSPECTION
PERIODIC AT ALL
BOLTED
CONNECTIONS
6. STRUCTURAL STEEL BOLTING:
3) FABRICATOR'S NDT REPORTS WHEN
FABRICATOR PERFORMS NDT VERIFY REPORTS EACH SUBMITTAL
2) WELDED JOINTS SUBJECT TO FATIGUE
WHEN REQUIRED BY AISC 360, APPENDIX
3, TABLE A-3.2
FIELD RADIOGRAPHIC OR
ULTRASONIC TESTING
PERIODIC
1) COMPLETE PENETRATION WELDS WHEN
REQUIRED BY ASIC 360, N5.5b
FIELD ULTRASONIC TESTING -
100%
PERIODIC
D. NON-DESTRUCTIVE TESTING (NDT) OF
WELDED JOINTS:
C. INSPECTION TASKS AFTER WELDING
(OBSERVE OR PERFORM FOR EACH WELDED
JOINT OR MEMBER, THE QA TASKS LISTED IN
AISC 360, TABLE N5.4-3)
FIELD INSPECTION
PERIODIC AT ALL
WELDED JOINTS
B. INSPECTION TASKS DURING WELDING
(OBSERVE OR PERFORM FOR EACH WELDED
JOINT OR MEMBER, THE QA TASKS LISTED IN
AISC 360, TABLE N5.4-2)
FIELD INSPECTION
PERIODIC AT ALL
WELDED JOINTS
A. INSPECTION TASKS PRIOR TO WELDING
(OBSERVE OR PERFORM FOR EACH WELDED
JOINT OR MEMBER, THE QA TASKS LISTED IN
AISC 360, TABLE N5.4-1)
FIELD INSPECTION
PERIODIC AT ALL
WELDED JOINTS
5. STRUCTURAL STEEL WELDING:
4. VERIFY MEMBER LOCATIONS, BRACES,
SITFFENERS, AND APPLICATION OF JOINT
DETAILS AT EACH CONNECTION COMPLY WITH
CONSTRUCTION DOCUMENTS
FIELD INSPECTION PERIODIC
3. EMBEDMENTS: VERIFY DIAMETER, GRADE, TYPE,
LENGTH, AND EMBEDMENT. SEE CONCRETE
CONSTRUCTION FOR ANCHORS
FIELD INSPECTION PERIODIC
2. MATERIAL VERIFICATION. REVIEW CERTIFIED
MILL TEST REPORTS AND IDENTIFICATION
MARKINGS ON WIDE-FLANGE SHAPES, HIGH
STRENGTH BOLTS, NUTS, AND WELDING
ELECTRODES
FIELD INSPECTION PERIODIC
1. FABRICATOR CERTIFICATION AISC CERTIFIED FABRICATOR
REQUIRED BY SPECIFICATION
STEEL CONSTRUCTION SERVICE EXTENT AGENT
14. Verify application and measurement of prestressing force Field Inspection Continuous ICC-SMSI
Field Inspection Periodic ICC-SMSI
13. Verify preparation, construction, and protection of masonry during cold weather (temperature below 40°F) or hot weather (temperature above 90°F)
12. Verify welding of reinforcement Field Inspection Continuous ICC-SMSI
ICC-SMSI
11. Verify type, size, and location of anchors, including details of anchorage of masonry to structural members, frames, or other construction.
Field Inspection Periodic
10. Verify size and location of structural masonry elements Field Inspection Periodic ICC-SMSI
9. Verify placement of grout and prestressing grout for bonded tendons
Field Inspection Continuous ICC-SMSI
8. Verify grout space prior to grouting Field Inspection Periodic ICC-SMSI
7. Verify placement of reinforcement, connectors, and prestressing tendons and anchorages
Field Inspection Periodic ICC-SMSI
6. Verify construction of mortar joints Field Inspection Periodic ICC-SMSI
ICC-SMSI
5. Verify grade, type, and size of reinforcement and anchor bolts, and prestressing tendons and anchorages
Field Inspection Periodic
4. Verify proportions of site-mixed mortar, grout and prestressing grout for bonded tendons
Field Inspection Periodic ICC-SMSI
Field Testing Continuous ICC-SMSI
3. Verification of Slump Flow and Visual Stability Index (VSI) of self-consolidating grout as delivered to the project
2. Verification of f'm prior to construction Unit Strength Method Periodic
1. Verify compliance with approved submittals Field Inspection Periodic
LEVEL B QUALITY ASSURANCE
MASONRY CONSTRUCTION
SERVICE EXTENT AGENT
3. VERIFICATION OF IN-SITU CONCRETE STRENGTH,
PRIOR TO STRESSING OF TENDONS IN POST
TENSIONED CONCRETE AND PRIOR TO REMOVAL
OF SHORES AND FORMS FROM BEAMS AND
STRUCTURAL SLABS.
REVIEW FIELD TESTING AND
LABORATORY REPORTS
PERIODIC
B. PERFORM INSPECTION OF WELDING AND
BOLTING IN ACCORANCE WITH STEEL
CONSTRUCTION
FIELD INSPECTION PERIODIC
A. INSPECT IN ACCORDANCE WITH
CONSTRUCTION DOCUMENTS
FIELD INSPECTION PERIODIC
2. ERECTION OF PRECAST CONCRETE MEMBERS
1. REVIEW PLANT OPERATIONS AND QUALITY
CONTROL PROCEDURES
PCI CERTIFIED PLANT
REQUIRED BY SPECIFICATION
PERIODIC
PRECAST CONCRETE CONSTRUCTION SERVICE EXTENT AGENT
2. EXTERIOR WALL COVERING AND WALL
CONNECTIONS TO ROOF AND FLOOR
DIAPHRAGMS
FIELD INSPECTION PERIODIC
1. ROOF COVERING, ROOF DECK, AND ROOF
FRAMING CONNECTIONS FIELD INSPECTION PERIODIC
WIND-RESISTING COMPONENTS SERVICE EXTENT AGENT
2. INSPECTION FOR SCREW ATTACHMENT,
BOLTING, ANCHORING, AND OTHER FASTENING
OF COMPONENTS WITHIN THE MAIN WIND
FORCE-RESISTING SYSTEM
FIELD INSPECTION PERIODIC
1. INSPECTION DURING WELDING OPERATIONS OF
ELEMENTS OF THE MAIN WIND FORCE-RESISTING FIELD INSPECTION PERIODIC
COLD-FORMED STEEL SPECIAL INSPECTIONS FOR
WIND RESISTANCE
SERVICE EXTENT AGENT
ALBIA - IOWA DOT MAINTENANCE GARAGE STRUCTURAL SCHEMATIC REFERENCE
(THIS IS SCHEMATIC ONLY - NOT FOR CONSTRUCTION)
TYPICAL COMPONENTS AND CLADDING WIND PRESSURES (PSF)
ZONE
10 SF OR SMALLER
NOTES:
1. REFER TO DESIGN CRITERIA FOR INFORMATION REGARDING GOVERNING BUILDING CODE.
2. PLUS AND MINUS SIGNS SIGNIFY PRESSURES ACTING TOWARD AND AWAY FROM THE SURFACES, RESPECTIVELY.
3. LINEAR INTERPOLATION IS PERMITTED FOR TRIBUTARY AREAS NOT SHOWN.
4. SEE FIGURE BELOW FOR ZONE DEFINITIONS.
5. NOTATION:
a: 10% OF LEAST HORIZONTAL DIMENSION OR 0.4h, WHICHEVER IS SMALLER, BUT NOT LESS THAN EITHER 4% OF
LEAST HORIZONTAL DIMENSION OR 3 FEET.
h: MEAN ROOF HEIGHT, IN FEET, EXCEPT THAT EAVE HEIGHT SHALL BE USED FOR ROOF ANGLES < 10°
Θ: ANGLE OF PLANE OF ROOF FROM HORIZONTAL, IN DEGREES.
TRIBUTARY AREA
50 SF 100 SF 200 SF 500 SF OR GREATER
a h a a a
FLAT ROOF
INTERIOR ZONES
FLOORS - ZONE1
WALLS - ZONE 4
END ZONES
FLOORS - ZONE 2
WALLS - ZONE 5
CORNER ZONES
FLOORS - ZONE 3
WALLS - ZONE 3
1'
0.6h
0.6h
0.2h 0.6h
1'
0.6h
+29.0 / -31.4 +26.0 / -28.4 +24.7 / -27.1 +23.4 / -25.8 +21.7 / -24.1
+29.0 / -38.6 +26.0 / -32.7 +24.7 / -30.1 +23.4 / -27.5 +21.7 / -24.1
+16.0 / -34.3 +16.0 / -34.3 +16.0 / -34.3 +16.0 / -34.3 +16.0 / -34.3
+16.0 / -47.7 +16.0 / -45.9 +16.0 / -45.1 +16.0 / -45.1 +16.0 / -45.1
+16.0 / -74.6 +16.0 / -55.8 +16.0 / -47.7 +16.0 / -47.7 +16.0 / -47.7
+16.0 / -34.3 +16.0 / -34.3 +16.0 / -34.3 +16.0 / -34.3 +16.0 / -34.3
1 2 3 5 6 7 8 94
A
B
16'-6" 14'-9"
P
S F
P
S F
OFFICE ROOF
GARAGE ROOF
1 2 3 5 6 7 8 94
A
B
.3 k
18.5k
18.5k
.4 k
.8 k
.8 k
F F F F F F F F F F F F F
A A
C C
44.5G16N8.4F23.1A
JOIST GIRDER NOTATION
AVERAGE GIRDER
DEPTH IN INCHES
NUMBER OF TOP CHORD
PANEL POINT SPACES FOR
JOIST SUPPORT. SEE PLAN
FOR EXACT JOIST LAYOUT.
FACTORED LOAD (ASD) AT EACH
JOIST SUPPORT LOCATION IN KIPS
FACTORED (ASD) AXIAL LOAD
THROUGH TOP CHORD IN KIPS
ALL AXIAL LOAD IS WIND LOAD
CRANE LOAD. SEE PLAN FOR
CRANE HANGER LOCATIONS AND
MAX HANGER LOADS. PANEL
POINTS MUST BE AT CRANE
RUNWAY LOCATIONS.
PER PLAN
/2
/2
BA D E
FC G
P R
E L
IM
IN
A R
Y
N O
T F
N
S T
R U
C T
IO
N
Io w a
I lli n n d ia n a
N e b ra s
A W
N
A P
P R
O V
E D
IS
S
U E
D F
O R
D A
T E
F
IE
L D
B O
O K
P R
O J E
C T
N O
H
P ri n te d
E n te r O ff ic e N u m b e r in G lo b a l P a ra m e te rs P h o n e w w w
.s h iv e -h a tt e ry
.c o m
BA D E FC G H
Autodesk Revit 2020
J E
F F
E R
E S
O N
M A
IN
T
E N
A N
C E
F A
C
IL
IT
Y
IO
W
A D
E P
T
O F
T R
A N
S P
O R
T A
T
IO
N
E n te r a d d re s s h e re
S002
L O
A D
IN
G
D
IA
G R
A M
S
L
IN
T E
L S
D O
C U
M E
N T
S
C R
M
J P
L
-0
-2
01/16" = 1'-0"E6
SNOW DRIFT PLAN
24'01/16" = 1'-0"A6
SHEAR WALL LOAD DIAGRAM
24'
01/8" = 1'-0"A4
TYPICAL TRUSS LOADING
12'
ALBIA - IOWA DOT MAINTENANCE GARAGE STRUCTURAL SCHEMATIC REFERENCE
(THIS IS SCHEMATIC ONLY AND THE BUILDING MAY INCLUDE MORE STORAGE BAYS AND UPDATED PER GEOTECHNICAL REPORT -
NOT FOR CONSTRUCTION)
1 2 3 5 6 7 8 94
A
B
23'-0" 26'-3 1/2" 21'-3 1/8" 22'-7" 20'-0" 20'-0" 23'-5 5/8" 31'-9"
188'-4 1/4"
TF3.0
T F
.0
W F
.5
W F
.0
W F
.0
T F
.0
TF3.0
WF2.0
W F
.0
W F
.0
WF2.0
W F
.0
B2
S501
TYP
A2
S501
TYP
D4
S500
TYP
TF2.0
S02S02
S03S03
S03S03
S02S02
S02S02
S03S03
S J
S J
S J
SJ SJ
SJ SJ
SJ SJ
SJ
SJ
SJ
SJ
SJ
SJ
S J
SJ SJ SJ SJ SJ
SJ SJ SJ SJ SJ
SJ
S J
S J
S J
SJ
SJ
SJ
SJ
SJ
SJ
SJ
S J
A2
S500
F2
S501
F2
S501
15'-0 1/4"
19'-0 1/4"
20'-0"
/8
/8
5'-0"20'-4 7/8" 10 5/8"
/8
MCJ
MCJ
MCJ
MCJ
F2
S501
S06
A2 S200
A3 S200
A
S
A
S
C4
S500
TYP
A4
S501
1'-0"
2'-5" w/ MECH
6'-0" VERIFY
/2
V E
R
IF
Y w
M
E C
H
SHEET NOTES:
1. SEE SHEET S000 FOR GENERAL NOTES AND SHEET S001 FOR REQUIRED SPECIAL INSPECTIONS.
2. SEE ARCHITECTURAL PLANS FOR DIMENSIONS AND INFORMATION NOT SHOWN ON THESE PLANS.
3. NORTH ARROW SHOWN IS FOR STRUCTURAL REFERENCE ONLY. SEE CIVIL DRAWINGS FOR ACTUAL BUILDING ORIENTATION.
4. "SJ" INDICATES SAWCUT JOINT, "CJ" INDICATES CONSTRUCTION JOINT. FOR SAWCUT AND CONSTRUCTION JOINTS SEE DETAILS
ON S500.
5. PROVIDE CORNER BARS AT FOUNDATION CORNERS AND T-INTERSECTIONS PER CORNER REINFORCING DETAIL ON S500.
6. "WFX" INDICATES CONTINUOUS WALL FOOTINGS. SEE S100 FOR WALL FOOTINGS SCHEDULE. TOP OF FOOTING SHALL BE -1'-0"
UNLESS NOTED OTHERWISE.
7. ALL CMU WALLS NOT SHOWN ON PLAN TO BE SUPPORTED BY THICKENED SLAB. FOR ADDITIONAL INFORMATION SEE THICKENED
SLAB DETAIL ON S500.
8. SEE PLUMBING DRAWINGS FOR SUBSURFACE DRAINAGE LAYOUT.
9. SEE MEP DRAWINGS FOR ADDITIONAL LOCATION OF IN-SLAB CLEANOUTS AND MANHOLES FOR SANITARY, STORM, AND PROCESS
PIPING.
10. CONTRACTOR SHALL COORDINATE ALL FOUNDATION WALL AND SLAB BLOCK-OUT REQUIREMENTS WITH MEP CONTRACTORS.
FOR ADDITIONAL INFORMATION SEE PIPE SLEEVE FOOTING STEP DETAIL ON S500.
BA D E
FC G
P R
E L
IM
IN
A R
Y
N O
T F
N
S T
R U
C T
IO
N
Io w a
I lli n n d ia n a
N e b ra s
A W
N
A P
P R
O V
E D
IS
S
U E
D F
O R
D A
T E
F
IE
L D
B O
O K
P R
O J E
C T
N O
H
P ri n te d
E n te r O ff ic e N u m b e r in G lo b a l P a ra m e te rs P h o n e w w w
.s h iv e -h a tt e ry
.c o m
BA D E FC G H
Autodesk Revit 2020
J E
F F
E R
E S
O N
M A
IN
T
E N
A N
C E
F A
C
IL
IT
Y
IO
W
A D
E P
T
O F
T R
A N
S P
O R
T A
T
IO
N
E n te r a d d re s s h e re
S100
F O
U N
D A
T
IO
N P
L A
N
D O
C U
M E
N T
S
C R
M
J P
L
-0
-2
NORTH
1/8" = 1'-0"A6
FOUNDATION PLAN
12'
WALL FOOTING SCHEDULE
MARK
SIZE LONGITUDINAL REINFORCING TRANSVERSE
REINFORCING REMARKSWIDTH DEPTH BOTTOM TOP
TF2.0 2' - 0" 2' - 6" (3) #5 (3) #5 #5 AT 12" OC
TF3.0 3' - 0" 2' - 6" (5) #5 (5) #5 #5 AT 12"OC
WF2.0 2' - 0" 1' - 0" (3) #5 #5 AT 12" OC
WF3.0 3' - 0" 1' - 0" (3) #5 #5 AT 12" OC
WF4.5 4' - 6" 1' - 0" (5) #5 #5 AT 12" OC
KEYNOTE LEGEND
KEY NOTE
S02 6" SLAB-ON-GRADE REINFORCED w/ #4 AT 18" OC, EW, CENTERED IN SLAB AND 3.5 LBS/CY SYNTHETIC
MACRO-FIBER. PLACE SLAB ON VAPOR BARRIER ON A
MINIMUM 24" LOW VOLUME CHANGE MATERIAL,
MINIMUM 12" OF MATERIAL CONFORMING TO IOWA DOT
SECTION4121 AGGREGATE GRADATION NO. 12A (MAY BE
CONSIDERED PART OF 24" OF LVC MATERIAL).
S03 5" SLAB-ON-GRADE REINFORCED W/ #4 AT 18" OC, EW,
CENTERED IN SLAB AND 3.5 LBS/CY SYNTHETIC
MACRO-FIBER. PLACE SLAB ON VAPOR BARRIER A
MINIMUM 24" LOW VOLUME CHANGE MATERIAL,
MINIMUM 12' OF MATERIAL CONFORMING TO IOWA DOT
SECTION4121 AGGREGATE GRADATION NO. 12A (MAY BE
CONSIDERED PART OF 24" OF LVC MATERIAL).
S06 8" CMU WALL REINFORCED W/ #5 @ 24" OC AND TOP
BOND BEAM REINFORCED w/ (2) #5. T/BOND BEAM = 11'-0"
ALBIA - IOWA DOT MAINTENANCE GARAGE STRUCTURAL SCHEMATIC REFERENCE
(THIS IS SCHEMATIC ONLY AND THE BUILDING MAY INCLUDE MORE STORAGE BAYS AND UPDATED PER GEOTECHNICAL REPORT -
B
W8X31 [18]
W8X31 [18]
W8X31 [18]
W8X31 [18]
W8X31 [18]
W8X31 [18]
W8X31 [18]
W8X31 [18]
LRFD = 9k
22KCS2
22KCS2
ASD = 6k
LRFD = 6k
ASD = 4k
LRFD = 9k
ASD = 6k
LRFD = 6k
ASD = 4k
LRFD = 9k
ASD = 6k
LRFD = 6k
ASD = 4k
LRFD = 9k
ASD = 6k
LRFD = 6k
ASD = 4k
LRFD = 9k LRFD = 6k
LRFD = 9k
ASD = 6k
LRFD = 6k
ASD = 4k
LRFD = 9k
ASD = 6k
LRFD = 6k
ASD = 4k
LRFD = 9k
ASD = 6k
LRFD = 6k
ASD = 4k
ASD = 6k ASD = 4k
LRFD = 9k
ASD = 6k
LRFD = 6k
ASD = 4k
LRFD = 9k
ASD = 6k
LRFD = 6k
ASD = 4k
LRFD = 9k
ASD = 6k
LRFD = 6k
ASD = 4k
LRFD = 9k
ASD = 6k
LRFD = 6k
ASD = 4k
LRFD = 9k
ASD = 6k
LRFD = 6k
ASD = 4k
S10
LRFD = 26k
ASD = 17k
S06
W8X31 [18]
LRFD = 9k
ASD = 6k
LRFD = 6k
ASD = 4k
LRFD = 9k
ASD = 6k
LRFD = 6k
ASD = 4k
LRFD = 9k
ASD = 6k
LRFD = 6k
ASD = 4k
LRFD = 9k
ASD = 6k
LRFD = 6k
ASD = 4k
LRFD = 9k
ASD = 6k
LRFD = 6k
ASD = 4k
LRFD = 9k
ASD = 6k
LRFD = 6k
ASD = 4k
LRFD = 26k
ASD = 17k
LRFD = 26k
ASD = 17k
LRFD = 26k
ASD = 17k
LRFD = 26k
ASD = 17k
LRFD = 26k
ASD = 17k
LRFD = 26k
ASD = 17k
LRFD = 24k
ASD = 16k
LRFD = 24k
ASD = 16k
22KCS2
22KCS2
22KCS2
22KCS2
22KCS2
22KCS2
22KCS2
22KCS2
22KCS2
22KCS2
22KCS2
22KCS2
22KCS2
22KCS2
22KCS2
22KCS2
22KCS2
A2
S510
TYP
B2
S510
TYP
D2
S510
TYP
LRFD = 24k
ASD = 16k W8X31 [18]
D4
S510
TYP
23'-0" 26'-3 1/2" 21'-3 1/8" 22'-7" 20'-0" 20'-0" 23'-5 5/8" 31'-9"
15'-0 1/4"
20'-0"
19'-0 1/4"
D6
S510
F4
S510
TYP
A2 S200
A3 S200
A
S
A
S
S12
L
L
/4
L
L
F4
S510
TYP
SHEET NOTES:
1. SEE SHEET S000 FOR GENERAL NOTES AND SHEET S001 FOR REQUIRED SPECIAL INSPECTIONS.
2. SEE ARCHITECTURAL PLANS FOR DIMENSIONS AND INFORMATION NOT SHOWN ON THESE PLANS.
3. NORTH ARROW SHOWN IS FOR STRUCTURAL REFERENCE ONLY. SEE CIVIL DRAWINGS FOR ACTUAL BUILDING ORIENTATION.
4. DECK BEARING ELEVATION (DBE) IS SHOWN ON PLAN. INTERPOLATE BETWEEN PROVIDED DBE TO DETERMINE INTERMEDIATE
POINTS IF NECESSARY. TYPICAL JOIST SEAT IS 2 1/2" DEEP.
5. ALL BEAMS FRAMING INTO COLUMNS SHALL BE CONNECTED WITH DOUBLE CLIP ANGLE CONNECTIONS. SECONDARY BEAMS
SHALL BE CONNECTED WITH SINGLE PLATE CONNECTIONS. SEE TYPICAL DETAILS ON SHEET S510.
6. JOIST BRIDGING TO BE DESIGNED AND DETAILED BY JOIST MANUFACTURER IN ACCORDANCE WITH SJI SPECIFICATIONS AND
UPLIFT PRESSURES INDICATED IN GENERAL NOTES. PROVIDE ADDITIONAL BRIDGING WHERE INDICATED ON DRAWINGS.
7. "LX" INDICATES MASONRY OR STEEL LINTEL. SEE ARCHITECTURAL FOR EXACT SIZE AND LOCATION OF OPENING. FOR LINTEL
SCHEDULE SEE SHEET S002.
8. CONTRACTOR TO COORDINATE WITH TRUSS MANUFACTURER FOR EXACT LOCATION AND QUANTITY OF TRUSSES.
9. SPRAY APPLIED FIREPROOFING OF COLUMNS, BEAMS, JOISTS, AND METAL DECK IS REQUIRED. SEE CODE PLAN FOR RATING
REQUIRED.
10. ALL FLOOR BEAMS TO HAVE UNIFORMLY SPACED 3/4"x4" SHEAR CONNECTORS. REFER TO BEAM LEGEND.
22K 22KW21x50 [16]
(135'-2")
BEAM SHAPE
ASD BEAM END
REACTION
TOP OF STEEL
ELEVATION
L=22K
LRFD BEAM
END REACTION
L=22K
# OF SHEAR CONNECTORS
REQUIRED ON BEAM. SEE
NOTE ABOVE FOR SIZE
BA D E
FC G
P R
E L
IM
IN
A R
Y
N O
T F
N
S T
R U
C T
IO
N
Io w a
I lli n n d ia n a
N e b ra s
A W
N
A P
P R
O V
E D
IS
S
U E
D F
O R
D A
T E
F
IE
L D
B O
O K
P R
O J E
C T
N O
H
P ri n te d
E n te r O ff ic e N u m b e r in G lo b a l P a ra m e te rs P h o n e w w w
.s h iv e -h a tt e ry
.c o m
BA D E FC G H
Autodesk Revit 2020
J E
F F
E R
E S
O N
M A
IN
T
E N
A N
C E
F A
C
IL
IT
Y
IO
W
A D
E P
T
O F
T R
A N
S P
O R
T A
T
IO
N
E n te r a d d re s s h e re
S110
M E
Z Z
A N
IN
E
/L O
W R
O O
F F
R A
M
IN
G P
L A
N
D O
C U
M E
N T
S
C R
M
J P
L
-0
-2
NORTH
1/8" = 1'-0"A6
MEZZANINE/LOW ROOF FRAMING
12'
01/8" = 1'-0"
BEAM LEGEND
KEYNOTE LEGEND
KEY NOTE
S06 8" CMU WALL REINFORCED W/ #5 @ 24" OC AND TOP
BOND BEAM REINFORCED w/ (2) #5. T/BOND BEAM = 11'-0"
S10 3" CONCRETE ON 2" VLI 20 GAUGE GALVANIZED METAL
DECK (5" TOTAL THICKNESS). REINFORCE W/ #3 AT 18"
OC, EW, CENTERED IN TOPPING & 3.5 LBS/CY
MACROFIBERS. T/SLAB = 12'-1"
S12 8" NON-LOAD BEARING CMU WALL REINFORCED W/ #5
AT 48" OC AND TOP BOND BEAM REINFORCED W/ (2) #5.
TOP BOND BEAM = 10'-10".
ALBIA - IOWA DOT MAINTENANCE GARAGE STRUCTURAL SCHEMATIC REFERENCE
(THIS IS SCHEMATIC ONLY AND THE BUILDING MAY INCLUDE MORE STORAGE BAYS AND UPDATED PER GEOTECHNICAL REPORT -
B
20K3
20K3
20K3
20K3
20K3
20K3
20K3
20K3
20K3
20K3
20K3
16K2
16K2
16K2
16K2
16K2
16K2
16K2
16K2
16K2
16K2
16K2
16K2
14K1
16K2
16K2
16K2
16K2
16K2
16K2
16K2
16K2
16K2
16K2
16K2
16K2
16K2
14K1
14K1
14K1
14K1
14K1
14K1
14K1
14K1
14K1
14K1
14K1
14K1
14K1
14K1
12K1
14K1
14K1
14K1
14K1
14K1
14K1
14K1
14K1
14K1
14K1
14K1
14K1
14K1
12K1
16K3
16K3
16K3
16K3
16K3
16K3
16K3
16K3
16K3
16K3
16K3
16K3
16K3
14K1
16K2
16K2
16K2
16K2
16K2
16K2
16K2
16K2
16K2
16K2
16K2
16K2
16K2
14K1
W x
23'-0" 26'-3 1/2" 21'-3 1/8" 22'-7" 20'-0" 20'-0" 23'-5 5/8"
156'-7 1/4"
16K2
20K3
20K3
20K3
16K314K114K116K216K220K316K2
.5
G N
X X
F
.5
G N
X X
F
.5
G N
X X
F
.5
G N
X X
F
T
C R
A N
E M
A X
H A
N G
E R
L O
A D
.4 k
M
IN
H A
N G
E R
L O
A D
.6 k
T
C R
A N
E M
A X
H A
N G
E R
L O
A D
.4 k
M
IN
H A
N G
E R
L O
A D
.6 k
F2
S510
A6
S510
TYP
D2
S510
TYPA3
S511
TYP
B4
S510
TYP
A4
S510
TYP
A2 S200
A3 S200
A
S
A2
S510
TYP
A2
S510
TYP CRANE RUNWAY CRANE RUNWAY CRANE RUNWAY CRANE RUNWAY CRANE RUNWAY CRANE RUNWAY
CRANE RUNWAYCRANE RUNWAYCRANE RUNWAYCRANE RUNWAYCRANE RUNWAYCRANE RUNWAY
A2
S510
TYP
A2
S510
TYP
SHEET NOTES:
1. SEE SHEET S000 FOR GENERAL NOTES AND SHEET S001 FOR REQUIRED SPECIAL INSPECTIONS.
2. SEE ARCHITECTURAL PLANS FOR DIMENSIONS AND INFORMATION NOT SHOWN ON THESE PLANS.
3. NORTH ARROW SHOWN IS FOR STRUCTURAL REFERENCE ONLY. SEE CIVIL DRAWINGS FOR ACTUAL
BUILDING ORIENTATION.
4. DECK BEARING ELEVATION (DBE) IS SHOWN ON PLAN. INTERPOLATE BETWEEN PROVIDED DBE TO
DETERMINE INTERMEDIATE POINTS IF NECESSARY. TYPICAL JOIST SEAT IS 2 1/2" DEEP.
5. ALL BEAMS FRAMING INTO COLUMNS SHALL BE CONNECTED WITH DOUBLE CLIP ANGLE CONNECTIONS.
SECONDARY BEAMS SHALL BE CONNECTED WITH SINGLE PLATE CONNECTIONS. SEE TYPICAL DETAILS ON
SHEET S510.
6. JOIST BRIDGING TO BE DESIGNED AND DETAILED BY JOIST MANUFACTURER IN ACCORDANCE WITH SJI
SPECIFICATIONS AND UPLIFT PRESSURES INDICATED IN GENERAL NOTES. PROVIDE ADDITIONAL BRIDGING
WHERE INDICATED ON DRAWINGS.
7. "LX" INDICATES MASONRY OR STEEL LINTEL. SEE ARCHITECTURAL FOR EXACT SIZE AND LOCATION OF
OPENING. FOR LINTEL SCHEDULE SEE SHEET S002.
8. CONTRACTOR TO COORDINATE WITH TRUSS MANUFACTURER FOR EXACT LOCATION AND QUANTITY OF
TRUSSES.
9. SPRAY APPLIED FIREPROOFING OF COLUMNS, BEAMS, JOISTS, AND METAL DECK IS REQUIRED. SEE CODE
PLAN FOR RATING REQUIRED.
22K 22KW21x50 [16]
(135'-2")
BEAM SHAPE
ASD BEAM END
REACTION
TOP OF STEEL
ELEVATION
L=22K
LRFD BEAM
END REACTION
L=22K
# OF SHEAR CONNECTORS
REQUIRED ON BEAM. SEE
NOTE ABOVE FOR SIZE
BA D E
FC G
P R
E L
IM
IN
A R
Y
N O
T F
N
S T
R U
C T
IO
N
Io w a
I lli n n d ia n a
N e b ra s
A W
N
A P
P R
O V
E D
IS
S
U E
D F
O R
D A
T E
F
IE
L D
B O
O K
P R
O J E
C T
N O
H
P ri n te d
E n te r O ff ic e N u m b e r in G lo b a l P a ra m e te rs P h o n e w w w
.s h iv e -h a tt e ry
.c o m
BA D E FC G H
Autodesk Revit 2020
J E
F F
E R
E S
O N
M A
IN
T
E N
A N
C E
F A
C
IL
IT
Y
IO
W
A D
E P
T
O F
T R
A N
S P
O R
T A
T
IO
N
E n te r a d d re s s h e re
S111
G A
R A
G E
R O
O F
F R
A M
IN
G
P L A
N S
D O
C U
M E
N T
S
A p p ro v e r
J P
L
-0
-2
NORTH
1/8" = 1'-0"A6
HIGH ROOF FRAMING PLAN (DBE=124'-0")
12'
01/8" = 1'-0"
BEAM LEGEND
ALBIA - IOWA DOT MAINTENANCE GARAGE STRUCTURAL SCHEMATIC REFERENCE
(THIS IS SCHEMATIC ONLY AND THE BUILDING MAY INCLUDE MORE STORAGE BAYS AND UPDATED PER GEOTECHNICAL REPORT -
100' - 0"
FIRST FLOOR
124' - 0"
GARAGE ROOF
114' - 0"
OFFICE ROOF
12356789 4
112' - 1"
S110_1_MEZZANINE
T/FLOOR
120' - 5 7/8"
T/CRANE RUNWAY
100' - 0"
FIRST FLOOR
124' - 0"
GARAGE ROOF
114' - 0"
OFFICE ROOF
1 2 3 5 6 7 8 94
112' - 1"
S110_1_MEZZANINE
T/FLOOR
120' - 5 7/8"
T/CRANE RUNWAY
100' - 0"
FIRST FLOOR
124' - 0"
GARAGE ROOF
114' - 0"
OFFICE ROOF
A B
112' - 1"
S110_1_MEZZANINE
T/FLOOR
120' - 5 7/8"
T/CRANE RUNWAY
100' - 0"
FIRST FLOORLEVEL 1
100' - 0"
124' - 0"
GARAGE ROOF
114' - 0"
OFFICE ROOF
AB
112' - 1"
S110_1_MEZZANINE
T/FLOOR
120' - 5 7/8"
T/CRANE RUNWAY
BA D E
FC G
P R
E L
IM
IN
A R
Y
N O
T F
N
S T
R U
C T
IO
N
Io w a
I lli n n d ia n a
N e b ra s
A W
N
A P
P R
O V
E D
IS
S
U E
D F
O R
D A
T E
F
IE
L D
B O
O K
P R
O J E
C T
N O
H
P ri n te d
E n te r O ff ic e N u m b e r in G lo b a l P a ra m e te rs P h o n e w w w
.s h iv e -h a tt e ry
.c o m
BA D E FC G H
Autodesk Revit 2020
J E
F F
E R
E S
O N
M A
IN
T
E N
A N
C E
F A
C
IL
IT
Y
IO
W
A D
E P
T
O F
T R
A N
S P
O R
T A
T
IO
N
E n te r a d d re s s h e re
S200
F R
A M
IN
G
E L E
V A
T
IO
N S
D O
C U
M E
N T
S
C R
M
J P
L
-0
-2
01/8" = 1'-0"A2
NORTH BUILDING ELEVATION
12'
01/8" = 1'-0"A3
SOUTH BUILDING ELEVATION
12'
01/8" = 1'-0"A5
WEST BUILDING ELEVATION
12'
01/8" = 1'-0"A6
EAST BUILDING ELEVATION
12'
ALBIA - IOWA DOT MAINTENANCE GARAGE STRUCTURAL SCHEMATIC REFERENCE
(THIS IS SCHEMATIC ONLY AND THE BUILDING MAY INCLUDE MORE STORAGE BAYS AND UPDATED PER GEOTECHNICAL REPORT -
HOOK DOWELS TO
MATCH CMU REINF.
1/2" ISOLATION JOINT
MATERIAL AND SEALANT
GROUT SOLID ALL VOIDS BELOW FFE
8" CMU WALL PER PLAN
FOOTING AND REINF.
PER PLAN & SCHEDULE
SLAB ON GRADE PER PLANE
FFE
PER PLAN
T/FTG
PER PLAN
NEEDS REVIEW
SLAB-ON-GRADE PER PLAN
8" CMU w/#5 VERT. @ 48" O.C IN
SOLID GROUTED CORES AND AT
CORNERS AND JAMBS - TYPICAL
INTERIOR WALLS
DOWEL TO MATCH CMU WALL
VERTICAL REINFORCING. PROVIDE
STD. HOOK OR DRILL AND EPOXY
USING HIT-HY 200 EPOXY SYSTEM
BY HILTI (8" EMBED)
PREPARE
SUBGRADE PER
PLAN
VAPOR BARRIER
1'-2" (2) #4 CONT.
SEE ARCHITECTURAL
DWGS FOR INTERIOR
CMU WALL LOCATIONS.
L A
P
NEEDS REVIEW
10 MIL VAPOR RETARDER -
SEE SPECIFICATIONS
NOTES:
1. ENGINEERED FILL SHALL COMPLY WITH THE FOLLOWING:
A. BE NATURALLY OR ARTIFICIALLY GRADED MIXTURE OF
NATURAL OR CRUSHED GRAVEL, CRUSHED STONE,
NATURAL OR CRUSHED SAND.
B. COMPLY WITH ASTM 2940.
C. BE UNIFORMLY GRADED WITH ALL AGGREGATE
PASSING THE 1" SIEVE SIZE.
ENGINEERED FILL COMPACTED TO 98%
STANDARD PROTOR DENSITY OR 65% RELATIVE
DENSITY. MINIMUM 24" LOW VOLUME CHANGE
MATERIAL, MINIMUM 12" OF MATERIAL
CONFORMING TO IOWA DOT SECTION4121
AGGREGATE GRADATION NO. 12A (MAY BE
CONSIDERED PART OF 24" OF LVC MATERIAL)
PREPARE SUBGRADE - SEE
SPECIFICATION APPROVED
BY SPECIAL INSPECTOR
CHAIR REINFORCING TO
PROPER POSITION
S E
E P
L A
N S
L A
B T
H
IC
K N
E S
S t) t/
T/SLAB
PER PLAN
CONCRETE SLAB ON GRADE -
SEE PLAN FOR THICKNESS
AND REINFORCING
CORNER BAR SAME
SIZE AND SPACE AS
HORIZONTAL STEEL
(LAP 36 DIA)
TWO MAT REINFORCING
SINGLE MAT REINFORCING
STANDARD
90° HOOK
COMPACTED
GRANULAR FILL
PER PLAN
REINF PER PLAN
DISCONT. THRU CJ
TROWEL FINISH UNO
VAPOR BARRIER
RESAW THIS
JOINT, CLEAN &
FILL w/JOINT
FILLER
ACI 302.1R-04 TABLE 3.2
SLAB DEPTH,
IN.
DIAMOND LOAD
PLATE DIM., IN.
DIAMOND LOAD PLATE SPACING
CENTER-TO-CENTER, IN.
5 TO 6 1/4x4 1/2x4 1/2 18
7 TO 8 3/8x4 1/2x4 1/2 18
9 TO 11 3/4x4 1/2x4 1/2 20
DIAMOND PLATE
DOWEL PER TABLE
NOTE: FOR SLAB DOWEL BETWEEN DIFFERENT THICKNESSES, USE
SMALLER SLAB DEPTH FOR DOWEL SIZE
BOND BREAKER
BETWEEN SURFACES
CONCRETE SLAB ON
GRADE PER PLAN
P E
R P
L A
N
COMPACTED
GRANULAR FILL PER
PLAN
VAPOR BARRIER
SAW JOINT PER
SPECIFICATION, CLEAN &
FILL w/JOINT SEALANT
TROWEL FINISH UNO REINF. PER PLAN
CONCRETE SLAB ON
GRADE PER PLAN
P E
R P
L A
N
D E
P T
H
/4
S L
A B
(EXTRA REINFORCING AT RE-ENTRANT CORNERS)
NOTES:
1. THESE REINFORCING BARS SHALL NOT
CROSS CONTROL, CONSTRUCTION, OR
ISOLATION JOINTS.
(2) #4x4'-0" @ TOP REINF MAT (TYP)
1/2" ISOLATION JOINT
MATERIAL AND SEALANT
8" CONCRETE WALL
REINF. w/ #4 AT 12" O.C. E.W.
MATCH
FTG ELEV.
8" SIDEWALLS WITH CORNER REINF. BARS EXTEND
HORIZ. BARS INTO FOUNDATION WALL AND FOOTING
1'-0" OR DRILL AND EPOXY AT CONTRACTORS
OPTION USING HIL-HY 200 BY HILTI (6" EMBED)
SEE TYPICAL EXTERIOR
TRENCH FOOTING
T/SLAB
PER PLAN
RIGID INSULATION PER ARCH,
LOCATE BELOW DOOR
THRESHOLD ON GRADE
SLAB ON GRADE PER PLAN
SLOPE SLAB PER CIVIL
1'-0"
4" SLAB REINF. W/ #4 AT 12"
E.W. CENTERED IN SLAB
4" VOIDFORM
#4 DOWELS AT 2'-0" O.C.
RIGID INSULATION
PER ARCH
FACE OF WALL
PER PLAN
SIDEWALK PER
CIVIL DRAWINGS
PVC PIPE SLEEVE,
ELEVATION PER PLAN
LOWER BOTTOM OF FOOTING
TO ENCASE PIPE SLEEVE IN
CONCRETE1
FOUNDATION WALL
DISCONTINUE TYP.
LONG.
REINFORCING WHERE
REQUIRED AND
PROVIDE MATCHING
BENT BARS 4'-0" MIN.
M
IN
NOTES:
1. GROUT LIFT HEIGHT TO CONFORM TO MSJC
REQUIREMENTS.
2. FOR FOOTING INFO AND ADD'L REINFORCING,
REFER TO PLANS & DETAILS
S T
R U
C T
N
O T
E S
T
Y P
S E
E P
L…
This is the start of the file's text. The full file is on GovTribe.