J4 - Specifications - VenTek AFM Conc Pad 61-903-I.pdf
PDF 619 KB Posted
- Attached to
- LEON SINKS AFM PAD & ELECTRICAL WORK
- Solicitation number
- 12445224B0011
- Issued by
-
Department of Agriculture Forest Service
About this file
This document contains specifications and requirements for the installation of a concrete pad and electrical work to support a future Automated Fee Machine (AFM) at a federal facility. The key details are:
The scope of work includes excavation, concrete installation with rebar, anchor bolt placement, electrical upgrades, patching, speed bump installation, and site cleanup/restoration. The magnitude of the project is less than $25,000. The period of performance is 30 days after the notice to proceed. A site visit is scheduled for 7/31/2024 and bids are due by 8/8/2024. Award will be made to the lowest priced, responsible offeror. The purchasing agency is the Department of Agriculture Forest Service. This document does not contain a Performance Work Statement or Statement of Objectives, but rather provides technical specifications and installation details for the concrete pad and electrical work.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
8.00" MIN.
CONCRETE
36.00" SQUARE
MIN. WIDTH
9.50"
9.50"
CONCRETE PAD
14" MIN
I
REVISION
REV H - REMOVE TABLE W/ AMP RATINGS &
ADD NOTE 3 W/ AMP RATINGS
REV I - UPDATE DRAWING WITH 2 PAGES
ECO# 2522
REV. DESCRIPTION:
61-903
DRAWING NO:
ENCLOSED
PEDESTAL INSTALLATION
SYSTEM VI
DRAWING NAME:
SHEET:
1 TO 1
SCALE:
2/09/21
VFW
DATE:
DATE:
DATE:
APPROVALS
DRAWN BY:
CHECKED BY:
APPROVED BY:
± 1°
ANGLES
.XX ± .030
.XXX ± .015
DECIMALS
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
& TOLERANCES ARE:
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION WHICH SHALL NOT BE REPRODUCED, DISCLOSED TO OTHERS, USED FOR MANUFACTURING OR ANY OTHER PURPOSE WITHOUT WRITTEN PERMISSION FROM VENTEK INTERNATIONAL.
InternationalVenTek
NOTES:
1. THE POWER AND PHONE LINES SHOULD EACH BE
RUN IN INDIVIDUAL PVC CONDUITS. IN ADDITION,
THE NETWORK LINE RUNNING IN SHOULD BE RUN
IN SEPARATE PVC CONDUITS.
2. BEFORE INSTALLING THE PEDESTAL, BE SURE
ALL POWER AND COMMUNICATION LINES HAVE
BEEN RUN IN SEPARATE CONDUIT.
3. AT 110/220V @20A CIRCUIT IS REQUIRED FOR
EACH PAY STATION.
CONC. PAD SPECIFICATIONS
4X REBAR
1/2" MIN
12" SQUARE
NOTE:
LEAVE SEVERAL FEET OF WIRE EXTENDING OUT OF THE
CONDUIT TO ENSURE EASY HOOKUP TO SYSTEM VI.
FRONT
USE CONDUIT PER ELECTRICAL CODE
SEE SHEET 2 FOR LENGTH
DRILL A Ø.625 (4PLCS)
ONLY WHEN A WEDGE
STUD ANCHOR IS USED
(5/8-11 X 6.00)
4.75"
CONDUIT
LOCATION
CONCRETE (REF)
FIGURE B
USE L-HOOK ANCHOR BOLTS
(MCM P/N 91587A310)
WHEN POURING NEW CEMENT
5/8-11 X 8.00
FIGURE A
USE WEDGE ANCHOR BOLTS
(MCM P/N 97110A452)
WHEN CEMENT ALREADY EXISTS
5/8-11 X 6.00
USE THIS DIMENSION FOR
BOTH L-HOOK ANCHOR BOLT
AND WEDGE ANCHOR BOLT
1.750"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1260 HOLM ROAD, SUITE A, PETALUMA, CA 94954 TEL. (707) 773-3373 FAX (707) 773-3381
AutoCAD SHX Text engineering the future of automated payment systems
AT LEAST 1.00" BELOW SURFACE
CROSS-SECTION
ELECTRICAL
CONDUIT
DETAIL B
SCALE 1 : 2
PEDESTAL MOUNTING HARDWARE:
(4x) 5/8-11 HEX NUT
(4x) 5/8" SAE FLAT WASHER
(4x) 5/8" LOCK WASHER
GROUND
PEDESTAL
(INSIDE)
M600/SVI
CONCRETE PAD
4X 1/2-13 HEX BOLT
4X 1/2 ID WASHER
DETAIL B
DIM A P/N DESCRIPTION
12"
04-370-01 ADA W/ CURB
18" 04-370-02 ADA W/O CURB
24" 04-370-03 WALK UP OR DRIVE UP W/ CURB
30" 04-370-04 WALK UP OR DRIVE THRU SURFACE
35" 04-370-05 DRIVE THRU
I
REVISION
REV H - REMOVE TABLE W/ AMP RATINGS &
ADD NOTE 3 W/ AMP RATINGS
REV I - UPDATE DRAWING WITH 2 PAGES
ECO# 2522
REV. DESCRIPTION:
61-903
DRAWING NO:
ENCLOSED
PEDESTAL INSTALLATION
SYSTEM VI
DRAWING NAME:
SHEET:
1 TO 1
SCALE:
2/09/21
VFW
DATE:
DATE:
DATE:
APPROVALS
DRAWN BY:
CHECKED BY:
APPROVED BY:
± 1°
ANGLES
.XX ± .030
.XXX ± .015
DECIMALS
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
& TOLERANCES ARE:
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION WHICH SHALL NOT BE REPRODUCED, DISCLOSED TO OTHERS, USED FOR MANUFACTURING OR ANY OTHER PURPOSE WITHOUT WRITTEN PERMISSION FROM VENTEK INTERNATIONAL.
InternationalVenTek
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1260 HOLM ROAD, SUITE A, PETALUMA, CA 94954 TEL. (707) 773-3373 FAX (707) 773-3381
ANCHOR BOLT TEMPLATE
SCALE 1 : 1
9.5" SQUARE
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION WHICH SHALL NOT BE REPRODUCED, DISCLOSED TO OTHERS, USED FOR MANUFACTURING OR ANY OTHER PURPOSE WITHOUT WRITTEN PERMISSION FROM VENTEK INTERNATIONAL.
I
R E
V I S
I O
N
R E
V
D
E S
C R
I P
T I O
N
D R
A W
I N
G
N
O
E N
C L
O S
E D
P E
D E
S T
A L
I N
S T
A L
L A
T I O
N
M
D R
A W
I N
G
N
A M
E
O
F
S H
E E
T
T
O
S C
A L E
V F
W
D A
T E
D A
T E
D A
T E
A P
P R
O V
A L S
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
A P
P R
O V
E D
B
Y
A N
G L E
S
X
X
D E
C I M
A L S
U N
L E
S
O
T H
E R
W I S
E
S
P E
C I F
I E
D
D I M
E N
S I O
R
C H
E S
T
O L E
R A
N C
R E
I n t e r n a t i o n a l
V e n T e k
S E
E
S
H E
T
WHEN CEMENT ALREADY EXISTS
DRILL Ø.625 (4PLCS)
FOR WEDGE ANCHOR BOLTS
(5/8-11 X 6.00)
SEE FIGURE A, SHT1
CONDUIT
LOCATION
4.75"
WHEN POURING NEW CEMENT
INSTALL L-HOOK ANCHOR BOLTS
(4PLCS, 5/8-11 X 8.00)
SEE FIGURE B, SHT1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1260 HOLM ROAD, SUITE A, PETALUMA, CA 94954 TEL. (707) 773-3373 FAX (707) 773-3381
25.0
34.0
57.3
A
B C
E
F
12" X 12" A
PEDESTAL
17.1 D
* ADA COMPLIANT HEIGHT (48" MAX.)
PEDESTAL OPTIONS
PEDESTAL
HEIGHT
(A)
ADA HEIGHT
(B)
MACHINE
HEIGHT
WITHOUT SOLAR
(C)
SOLAR MOUNT
(D)
OVERALL HEIGHT
WITH SOLAR
(E)
COIN CUP
HEIGHT
(F)
12" 40" * 46" 32" 68" 19.4" 18" 46" * 52" 38" 74" 25.4" 24" 52" 58" 44" 80" 31.4" 30" 58" 64" 50" 86" 37.4"
VenTek International engineering the future of automated payment systems
1260 HOLM ROAD, SUITE A, PETALUMA, CA 94954
TEL. (707) 773-3373 FAX (707) 773-3381
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION WHICH SHALL NOT BE REPRODUCED, DISCLOSED TO OTHERS, USED FOR MANUFACTURING OR ANY OTHER PURPOSE WITHOUT WRITTEN PERMISSION FROM VENTEK INTERNATIONAL.
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
& TOLERANCES ARE:
DECIMALS
.XX .030
.XXX .015
ANGLES
DRAWN BY:
CHECKED BY:
APPROVED BY:
APPROVALS
DATE:
DATE:
DATE:
MCR 3/13/2018
--SCALE: 1 TO 12 SHEET SIZE: B
DRAWING NAME:
OVERALL DIMENSIONNING
M600 WITH PEDESTAL
AND SOLAR OPTION
DRAWING NO:
61-910
REV. DESCRIPTION:
ADD COIN CUP HEIGHT
ECO# 2050
REVISION
C
FILE LOCATION: DP/M600 TOP ASSY
3D FILENAME: 61-910 M600 With Solar & PedestalSHEET: 1 OF 1
| Sheets and Views |
| Layout1 |
File details come from the government source that posted it. Updated .