This technical drawing from Barber Nichols is a detailed engineering specification for a liquid argon exterior interface pump assembly. The document provides comprehensive mechanical design details for a vertical-orientation pump with specific dimensional specifications, including inlet and discharge outer diameters, rotation orientation (counterclockwise), and precise mounting requirements. Key technical specifications include a pump mounting plate minimum thickness of 0.75 inches, recommended pipe length requirements for inlet and discharge (5-10 diameters and 2-3 diameters respectively), and maximum allowable tubing loads of 50 LBF in X, Y, Z directions. The drawing includes warnings about pump orientation, motor cooling, and installation guidelines, with specific details about weld requirements, housing materials (304/L or 316/L stainless steel), and installation clearance needs, including a minimum 52-degree angular clearance arc for pump housing installation.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PREL

IMIN

ARY

Nichols Barber

ROTATION CCW

8.90in 226.06mm

13.50in 343.00mm

21.80in 553.82mm

24.59in 624.69mm

15.70in 398.81mm

5.60in 142.24mm

4.50in 114.30mm

INLET O.D.

2.60in 66.04mm

3.50in 88.90mm

DISCHARGE O.D.

A

3/4" NPT

MOTOR JUNCTION BOX

CONNECTION

ROTATING ASSY BOLTS

SOCKET HEAD CAP SCREW 1/4-20

REMOVE TO PULL ROTATING ASSY

CUSTOMER WELD

NO LIFTING OR BENDING

OF PUMP COMPONENTS BELOW

PUMP MOUNTING PLATE

MAX ALLOWABLE TUBING LOADS:

50 LBF IN X,Y,Z (87 LBF MAGNITUDE)

5 FT-LBS IN X,Y,Z (8.6 FT-LBS MAGNITUDE)

IT IS RECOMMENDED TO INCLUDE THE

FOLLOWING DIAMETERS OF PIPE LENGTH ON

THE END OF THE INLET AND DISCHARGE BEFORE A 90 DEGREE ELBOW.

SMOOTH RADIUS ELBOWS ARE RECOMMENDED TO REDUCE PRESSURE DROP.

INLET: MINIMUM ALLOWABLE 5 DIAMETERS.

IDEAL 10 DIAMETERS

DISCHARGE: MINIMUM ALLOWABLE 2 DIAMETERS.

IDEAL 3 DIAMETERS.

WARNING:

PUMP CAN ONLY BE OPERATED IN THE

INDICATED ORIENTATION

VERTICAL ORIENTATION

DIRECTION OF GRAVITY

SMA FEEDTHRU FOR ACCELEROMETER

SUPPLIED BY BARBER-NICHOLS

SUPPLIER PN: 47188-1

CONNECTOR: 1/4"-36 UNS-2A THREAD

MOTOR COOLED BY FAN

DO NOT OBSTRUCT AREA ABOVE OR AROUND

USE HOIST RINGS FOR LIFTING

3 PLCS

REMOVE AFTER FINAL ASSEMBLY TO

PREVENT NOISE/VIBRATION

DURING OPERATION.

SAVE FOR MAINTENANCE

ISOMETRIC VIEW

REFERENCE ONLY

DO NOT SCALE

.75in 19.05mm

PUMP MOUNTING PLATE MINIMUM THICKNESS

PART OF CUSTOMER FACILITY AND RESPONSIBILITY

NOT SUPPLIED BY BARBER-NICHOLS

.16in 4.06mm

FLANGE THICKNESS

.25 6.35

MIN OVERLAP

BETWEEN WELD-IN HOUSING O.D.

AND MOUNT I.D.

18.00in 457.20mm

21.00in 533.40mm

DETAIL A

WELD DETAIL

SCALE 1 : 1

PUMP MOUNTING PLATE

PART OF CUSTOMER FACILITY

NOT SUPPLIED BY BARBER-NICHOLS

WELD-IN HOUSING

MATERIAL: 304/L OR 316/L SS

SUPPLIED BY BARBER-NICHOLS

SEAL WELD

BY CUSTOMER

G

D

H

A

B

F

C

E

INTERPRET PER ASME

Y14.5M-1994

441.866 LBS. 2OF1SHEET1:3BNCP-76-000MODEL FILE:

THIRD ANGLE PROJECTION

C:\SOLIDWORKS Data\PDM Vault\PROJECTS\BNCP\BNCP-76\CAD\

- - - -ELEC

PROJECT

FNL17049

UNLESS OTHERWISE SPECIFIED

DIM ARE IN INCHES, TOL ARE:

IN MM

.0 ± .030 ± .76 .00 ± .015 ± .38 .000 ± .005 ± .13

ANGULAR ± 2°

ARVADA, COLORADO

80002

QA

REV.

SURFACE ROUGHNESS 125

LIQUID ARGON EXTERIOR

INTERFACE DETAILS

CURRENT UPDATE:

BREAK EDGES: .020 MAX

ALL FILLET RADII: .005 / .020

REMOVE BURRS

CAGE

AERO

57377

PRJ

MFG

BNCP-76-998

SEE BOM

FLDR: E

NEXT ASSY

DRAWING NO.

WT, CALC:SCALE

SIZE

TITLE

CHK

DWN

HEAT TREATMENT

MATERIAL

APPROVEDDATE

REVISION HISTORY

DESCRIPTIONREVZONE

A A

B B

C C

D D

E E

F F

G G

H H

SHT FORMAT REV C

PREL

IMIN

ARY

Nichols Barber

16.00in 406.40mm

MINIMUM CLEARANCE

HOLE FOR PUMP

HOUSING INSTALLATION

R24.00in 609.60mm

MINIMUM ANGULAR CLEARANCE ARC

FOR PUMP HOUSING INSTALLATION

52°

PUMP INSTALLATION VIEW

PUMP MOUNTING PLATE

G

D

H

A

B

F

C

E

A A

B B

C C

D D

E E

F F

G G

H H

SHT FORMAT REV C

LIQUID ARGON EXTERIOR

INTERFACE DETAILS

C:\SOLIDWORKS Data\PDM Vault\PROJECTS\BNCP\BNCP-76\CAD\

ARVADA, COLORADO

80002

REV.

OFSHEET

BNCP-76-000

CURRENT UPDATE:

MODEL FILE:

CAGE

57377 BNCP-76-998

1:3

FLDR:

E

DRAWING NO.

SCALE

SIZE

TITLE

Sheet1
Drawing View21
Drawing View22
Drawing View23
Detail View A (1 : 1)
Sheet2
Drawing View33