This document is a Minor Site Plan prepared by Kimley-Horn and Associates for the City of Ocala, Florida, detailing the construction of a SunTran Restrooms and Kiosk facility located at NE 5th Street and NE 1st Avenue. The project involves constructing a 460 square foot single-story building with a finished floor elevation of 69.00 feet, including restroom facilities and a ticketing kiosk. The site plan includes detailed drawings for demolition, layout, grading, stormwater pollution prevention, and construction details, with the project scheduled for April 2024. The plan encompasses utility connections including water, sewer, electric, and communication lines, with specific requirements for site preparation, erosion control, and landscaping.
The project site covers 2.1 acres with 126,716 square feet of impervious area, situated in the Central Core high-intensity zone. Utility providers include the City of Ocala for water and sewer, City of Ocala Electric Utility, and various communication providers like Lumen and Verizon. The site plan includes comprehensive notes on construction standards, including specific requirements for pavement, sidewalks, drainage, and environmental protections. The estimated sewer demand is 96 users per day at 384 gallons, with a potable water demand of 461 gallons per day. The plan emphasizes environmental controls, including stormwater management, erosion prevention, and specific guidelines for waste management, petroleum product handling, and non-stormwater discharges.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W
W .K
IM
LE
Y- H
O R
N .C
O M
R
EG
IS
TR
Y
N O
. 3
S E
TH
S
TR
EE
T, S U
IT
E
0, O C
AL
A, F
LO
R
ID
A
PH
O
N E:
-4
-3
SU
N
TR
AN
R
ES
TR
O
O M
S
AN
D K
IO
SK
PR
EP
AR
ED
F O
R
C
IT
Y O
F O
C
AL
A
C O
VE
R
S H
EE
T
C01
C01 - COVER SHEET
C01.1 - MASTER LAYOUT
C02 - DEMOLITION PLAN
C03 - LAYOUT AND GRADING PLAN
C04 - STORMWATER POLLUTION PREVENTION PLAN
C05 - CONSTRUCTION DETAILS
DRAWING INDEX
ZONING
PARCEL ACCT. NO.
FUTURE LAND USE
PROJECT AREA
PROJECT NAME
PROJECT LOCATION
OWNER
SITE DATA:
126,716 S.F. = 2.91 ACRES
28235-001-00
OCALA SUNTRAN RESTROOMS AND KIOSK
HIGH INTENSITY/CENTRAL CORE
IMPERVIOUS AREA
NE 5TH ST @ NE 1ST AVE
CITY OF OCALA
1805 NE 30TH AVE. BLDG 700
OCALA, FL 34470-4882
OCALA, FL 34785
OF KIMLEY-HORN AND ASSOCIATES, INC.
ENGINEER'S CERTIFICATION:
I HEREBY CERTIFY THAT THESE PLANS AND CALCULATIONS WERE COMPLETED IN
ACCORDANCE WITH ALL APPLICABLE REQUIREMENTS OF THE CITY OF OCALA LAND
DEVELOPMENT CODE EXCEPT AS WAIVED, THAT THE ADJACENT PROPERTIES WILL BE
PROTECTED FROM STORMWATER DAMAGE AS A RESULT OF THIS PROPOSED
DEVELOPMENT, THAT THE DRAINAGE FACILITIES INCORPORATED HEREON ARE SUFFICIENT
IN SIZE, AND THAT SIGHT DISTANCE AT DRIVEWAYS COMPLY WITH A.A.S.H.T.O. AND THE
F.D.O.T. SITE IMPACT HANDBOOK. I FURTHER CERTIFY THAT THIS PLAN MEETS ALL
REQUIREMENTS OF THE F.D.E.P. AND S.J.R.W.M.D.
DATE:
SURVEY:
CONTACT: ECHEZABAL AND ASSOCIATES, INC.
NOTE: SEE TOPOGRAPHIC SURVEY BY ECHEZABAL AND
ASSOCIATES FOR BEARINGS & DISTANCES,
MONUMENTATION, SECTION DATA, DATUM, FENCES,
NOTES, AND SURVEYOR'S CERTIFICATION.
GENERAL NOTES:
THE CHARACTER AND INTENDED USE OF THIS DEVELOPMENT SHALL BE
TO CONSTRUCT 460 SF TICKET KIOSK AND RESTROOMS BUILDING.
GENERAL STATEMENT:
1. REPRODUCTION OF THESE PLANS IS NOT VALID UNLESS SIGNED BY
THE ENGINEER IN RESPONSIBLE CHARGE AND SEALED WITH RAISED
EMBOSSED SEAL.
2. COPIES OF THESE PLANS AS DESIGNED BY THE PROFESSIONAL
ENGINEER HAVE BEEN RETAINED BY THE ENGINEER AND HE WILL NOT
BE HELD RESPONSIBLE FOR ANY SUBSEQUENT UNAUTHORIZED
CHANGES TO THE REPRODUCIBLE ORIGINAL DOCUMENTS.
STANDARD NOTES:
VICINITY MAP
NORTH
1. ALL CONSTRUCTION COVERED BY THESE PLANS SHALL COMPLY WITH THE MATERIAL REQUIREMENTS AND QUALITY CONTROL
STANDARDS CONTAINED IN THE CITY OF OCALA LAND DEVELOPMENT CODE AS APPLICABLE.
2. NO CHANGE TO THE WORK AS SHOWN ON THE APPROVED PLANS SHALL BE MADE WITHOUT NOTIFICATION TO AND APPROVAL
OF BOTH THE CITY ENGINEER AND PROJECT ENGINEER.
3. THE CONTRACTOR SHALL VERIFY THE LOCATION AND COVER OF ALL EXISTING UTILITIES AND REPORT ANY DISCREPANCY TO THE PROJECT ENGINEER. THERE MAY BE ADDITIONAL UTILITIES NOT SHOWN ON THESE PLANS. CAUTION IS ADVISED PRIOR
TO DIGGING. IT IS IMPORTANT THAT "UTILITY LOCATES" BE PERFORMED ON-SITE.
4. TYPE III SILT FENCE SHALL BE INSTALLED AS SHOWN ON THESE PLANS PRIOR TO ANY CONSTRUCTION, MAINTAINED DURING
THE LIFE OF THE PROJECT, AND REMOVED FOLLOWING COMPLETION OF CONSTRUCTION.
5. THE SITE SHALL REMAIN FREE OF EXCESS DUST AND DEBRIS AT ALL TIMES. ANY INCIDENCE OF EROSION, SEDIMENTATION, DUST OR DEBRIS OCCURRING OFF-SITE AS A RESULT OF CONSTRUCTION ACTIVITIES ON THIS DEVELOPMENT SHALL BE
CORRECTED BY THE CONTRACTOR WITHIN 48 HOURS OF EACH OCCURRENCE.
6. ALL DRAINAGE FACILITIES AND STORM STRUCTURES MUST BE BUILT PRIOR TO CONSTRUCTION OF ANY IMPERVIOUS
SURFACES.
7. ASPHALT PAVEMENT ON-SITE SHALL BE 1-1/2"-THICK (F.D.O.T. TYPE SP-9.5) ON 8" LIMEROCK BASE (98% MAX DENSITY, 100 LBR), ON 12" STABILIZED SUBGRADE (98% MAX DENSITY, 40 LBR). CONSTRUCTION REQUIREMENTS OF THE FDOT STANDARD
SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION (LATEST EDITION) SHALL GOVERN.
8. IF UNSUITABLE MATERIAL IS ENCOUNTERED WITHIN PARKING AREA, TWO (2) FEET OF UNDERCUT BELOW THE PROPOSED LIMEROCK BASE TOGETHER WITH SUITABLE BACKFILL MATERIAL, IS REQUIRED. THE CONTRACTOR SHOULD PROVIDE A UNIT PRICE IN HIS INITIAL BID, AND HE SHALL NOTIFY THE PROJECT ENGINEER WHEN UNSUITABLE MATERIAL IS ENCOUNTERED.
BEFORE PROCEEDING WITH ANY WORK RELATED TO UNSUITABLE MATERIAL, THE CONTRACTOR IS ADVISED TO CONTACT A LICENSED GEOTECHNICAL ENGINEER TO DETERMINE THE SUITABILITY OF THE INSITU SOIL AND THE AREA OF UNDERCUT THAT
IS REASONABLY REQUIRED.
9. ALL SIGN POSTS TO BE U-CHANNEL GALVANIZED STEEL 2lbs/L.F. BREAKAWAY POSTS.
10. ANY DISTURBED AREAS LEFT UNPAVED SHALL BE FINISH GRADED AND SODDED WITH ARGENTINE BAHIA. CONTRACTOR MUST
FINISH GRADE AT 2" UNDERCUT OF PROPOSED GRADES TO ALLOW FOR THICKNESS OF SOD.
11. IF A SINKHOLE SHOULD FORM ON THIS SITE, ALL APPLICABLE REPAIR PROCEDURES SHALL BE FOLLOWED AS OUTLINED IN TYPICAL SINK CHIMNEY REPAIR DETAIL SHOWN HEREON. ALSO, THE CITY OF OCALA AND SJRWMD SHALL BE NOTIFIED
IMMEDIATELY.
12. KIMLEY-HORN, INC. AND ITS EMPLOYEES ARE NOT RESPONSIBLE FOR ON-SITE SAFETY DURING CONSTRUCTION.
13. THERE ARE NO WETLANDS ON THIS SITE.
14. THE SITE CONTRACTOR SHALL INCLUDE THE PROVISION OF A COMPREHENSIVE AS-BUILT SURVEY FOR THE ENTIRE PROJECT IN HIS CONTRACT. THIS SURVEY MUST BE PERFORMED BY A FLORIDA REGISTERED LAND SURVEYOR (FIELD AND OFFICE WORK) AND PROVIDED TO THE PROJECT ENGINEER IN BOTH PDF AND ACAD FORMATS PRIOR TO C.O. THE AS-BUILT SURVEY SHALL INCLUDE VALVE TIE SHEETS FOR ANY NEW VALVES, TOGETHER WITH THE TYPE, SIZE, LOCATION, DEPTH, SLOPE (WHERE APPLICABLE), ETC. OF ALL UTILITIES. IMPORTANT!! THE LOCATIONS AND TOP OF PIPE ELEVATIONS FOR ALL VERTICAL & HORIZONTAL BENDS, TEES, VALVES, AND WYES MUST BE PROVIDED ON THE AS-BUILTS. THE PROJECT ENGINEER WILL REVIEW THE INFORMATION FOR CERTIFICATION OF COMPLETION BEFORE FINAL PAYMENT WILL BE APPROVED. AN INCOMPLETE AND/OR INACCURATE AS-BUILT SURVEY WILL BE REJECTED, AND THE ENGINEER WILL NOT BE RESPONSIBLE FOR ANY DELAY IN
OBTAINING THE C.O.
15. THE GEOTECHNICAL TESTING COMPANY SHALL BE HIRED BY THE OWNER AND THE SPECIFICATIONS FOR THE TESTING SHALL
BE GIVEN BY THE PROJECT ENGINEER. ALL TESTS SHALL BE PAID FOR BY THE CONTRACTOR.
FLOOD ZONE
NEW BUILDING SIZE 460 S.F.
NEW BUILDING HEIGHT 15 FEET
AGENCY PERMITS:
CITY OF OCALA ONGOING
SJRWMD ONGOINGUTILITY PROVIDERS:
ELECTRIC:
CITY OF OCALA ELECTRIC UTILITY
1805 NE 30TH AVE., BLDG 400
OCALA, FL 34470
RANDY HAHN
(352) 351-6615
FIBER & TELEPHONE:
LUMEN (LOCAL)
501 MCCORMACK ST
LEESBURG, FL 34748
JOHN PLAMONDON
(352) 425-4444
FIBER:
CITY OF OCALA FIBER
1805 NE 30TH AVE, BLDG. 500
OCALA, FL 34470
OSHANE PARKER
(352) 401-6950
FIBER & TELEPHONE:
LUMEN (NATIONAL)
7003 PRESIDENTS DR, STE. 100
ORLANDO, FL 32809
MICHAEL HUNT
716-480-2076
NEW BUILDING NUMBER OF STORIES 1 STORY
Know what'sbelow.
Callbefore you dig.
CALL 2 BUSINESS
DAYS BEFORE
YOU DIG
IT'S THE LAW!
DIAL 811
SUNSHINE STATE ONE CALL OF FLORIDA, INC.
OCALA SUNTRAN
RESTROOMS AND KIOSK
CITY OF OCALA, FLORIDA
APRL 2024
MINOR SITE PLAN
FOR
PARCEL ID: 28235-001-00
PROJECT
LOCATION
PROJECT
AREA
SITE
NO CHANGE FROM PRE-DEVELOPMENT
WATER & SEWER:
CITY OF OCALA, WATER & SEWER
2100 NE 30TH AVE
OCALA, FL 34470
STACEY FERRANTE
(352) 351-6775
COMMUNICATION LINES & FIBER:
VERIZON
400 S. LAKE DESTINY
ORLANDO, FL 32810
TIM COLE
(407)-618-2078
PRE-CONSTRUCTION MEETING:
NO SITE WORK SHALL BE CONDUCTED PRIOR TO OBTAINING A SITE PERMIT FROM THE CITY
OF OCALA. CALL THE CITY GROWTH MANAGEMENT DEPARTMENT AT 352-692-8421 TO
SCHEDULE A PRE-CONSTRUCTION MEETING.
GAS:
TECO PEOPLES GAS-OCALA
316 SW 33RD AVE.
OCALA, FL 34474
LANDON MEAHL
(407) 408-5566
SPLM24-45592-Suntran Union Station Restroom - Kiosk 5/9/2024
NE 5TH ST
N E
1S T
AV
E
N M
AG
N
O
LI
A
AV
E
N E
O
SC
EO
LA
A
VE
PARCEL #:
28235-005-00
PARCEL #:
28235-004-00
PARCEL #:
28235-002-00
PARCEL #:
28235-000-00
PARCEL #:
28235-001-00
W W
W .K
IM
LE
Y- H
O R
N .C
IS
TR
Y
N O
. 3
S E
TH
S
TR
EE
T, S U
IT
E
0, O C
AL
A, F
LO
R
ID
A
PH
O
N E:
-4
-3
SU
N
TR
AN
R
ES
TR
O
O M
S
AN
D K
IO
SK
PR
EP
AR
ED
F O
R
C
IT
Y O
F O
C
AL
A
M
AS
TE
R
L
AY
O U
T
C01.1
NORTH
SPLM24-45592-Suntran Union Station Restroom - Kiosk 5/9/2024
EXISTING COVERED
BOARDING AREA
TO REMAIN
EXISTING
CONCRETE
EXISTING ASPHALT
EXISTIN
G
CONCRETE
SID
EWALK
EXISTING
CONCRETE
EXISTING 6" WATER MAIN (APPROXIMATE)
CONTRACTOR TO VERIFY LOCATION AND PROTECT
FROM DAMAGES DURING CONSTRUCTION
EXISTING 8" SANITARY
CONTRACTOR TO VERIFY LOCATION AND PROTECT
FROM DAMAGES DURING CONSTRUCTION
INSTALL INLET PROTECTION BARRIER
EXISTING STOP SIGN
AND LIGHT POLE TO REMAIN
EXISTING ELECTRICAL
STRUCTURE TO REMAIN
EXISTING
HANDRAIL
TO REMAIN
EXISTING TREE
TO REMAIN
CAUTION:
EXISTING ELECTRICAL CONDUITS 3 FT DEEP
TO BE PROTECTED DURING CONSTRUCTION
TREE CANOPY
(APPROX.)
REMOVE AND REPLACE EXISTING
CURB AND GUTTER
REMOVE AND REPLACE EXISTING
CURB AND GUTTER
REMOVE AND REPLACE
PAVEMENT STRIPING (TYP.)
APPROXIMATE LOCATION OF EXISTING
DRAIN OUTLET TO BE FIELD LOCATED,
REMOVED, AND REPLACED.
EXISTING CONCRETE SIDEWALK
TO BE REMOVED AND REPLACED
W W
W .K
IM
LE
Y- H
O R
N .C
IS
TR
Y
N O
. 3
S E
TH
S
TR
EE
T, S U
IT
E
0, O C
AL
A, F
LO
R
ID
A
PH
O
N E:
-4
-3
SU
N
TR
AN
R
ES
TR
O
O M
S
AN
D K
IO
SK
PR
EP
AR
ED
F O
R
C
IT
Y O
F O
C
AL
A
D
EM
O
LI
TI
O
N P
LA
N
C02
NORTH
INSTALL SILT FENCE. SEE DETAIL ON SHEET C04.
INSTALL EITHER 2"x4" WOODEN FENCE OR ORANGE CONSTRUCTION BARRIER FENCE AS SHOWN. SEE DETAILS
ON SHEET C05.
REMOVE EXISTING ASPHALT PAVEMENT WHERE SHOWN CROSS-HATCHED.
REMOVE EXISTING CURB AND CONCRETE WHERE SHOWN SHADED.
REMOVE EXISTING BOLLARDS.
REMOVE AND REPLACE ALL GRASSED AREA THAT IS DISTURBED DURING CONSTRUCTION.
DEMOLITION KEYNOTE LEGEND:
DEMOLITION PLAN
TREE PRESERVATION NOTE:
TREE PRESERVATION MEASURES MUST BE INSTALLED AND
INSPECTED PRIOR TO ANY DEMOLITION ACTIVITIES.
1. ALL MATERIAL REMOVED FROM THIS SITE BY THE CONTRACTOR SHALL BE DISPOSED OF BY THE CONTRACTOR IN A LEGAL MANNER.
2. REFER TO THE TOPOGRAPHIC SURVEY FOR ADDITIONAL DETAILS OF EXISTING STRUCTURES, ETC., LOCATED WITHIN THE PROJECT SITE. UNLESS OTHERWISE NOTED, ALL EXISTING BUILDINGS, STRUCTURES, SLABS, CONCRETE, ASPHALT, DEBRIS PILES, SIGNS, AND ALL APPURTENANCES ARE TO BE REMOVED FROM THE SITE BY THE CONTRACTOR AND PROPERLY DISPOSED OF IN A LEGAL MANNER AS PART OF THIS CONTRACT. SOME ITEMS TO BE REMOVED MAY NOT BE DEPICTED ON THE TOPOGRAPHIC SURVEY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VISIT THE SITE AND DETERMINE THE FULL EXTENT OF ITEMS TO BE REMOVED. IF ANY ITEMS ARE IN QUESTION, THE CONTRACTOR SHALL CONTACT THE OWNER PRIOR TO REMOVAL OF SAID ITEMS.
3. THE CONTRACTOR SHALL REFER TO THE DEMOLITION PLAN FOR DEMOLITION AND/OR PRESERVATION OF EXISTING TREES AND NATURAL AREAS. ALL TREES NOT SPECIFICALLY SHOWN TO BE PRESERVED OR RELOCATED SHALL BE REMOVED AS PART OF THIS CONTRACT IF THEY CONFLICT WITH THE CONSTRUCTION OF ANY OF THE PROPOSED IMPROVEMENTS. TREE PROTECTION BARRICADES AND FENCING SHALL BE INSTALLED AND INSPECTED IN ACCORDANCE WITH THE LOCAL JURISDICTIONAL
REQUIREMENTS PRIOR TO ANY DEMOLITION ACTIVITIES TAKING PLACE.
GENERAL DEMOLITION NOTES:
SAWCUT (TYP.)
SAWCUT (TYP.)
STORAGE AND
STAGING AREA
SAWCUT (TYP.)
SPLM24-45592-Suntran Union
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
E E
E E
E E
E E
E E
E E
E
E E
E E
E E
E E
E E
E E
E
EXISTING ASPHALT
EXISTING 8" SANITARY
CONTRACTOR TO VERIFY LOCATION AND
PROTECT FROM DAMAGES DURING
CONSTRUCTION
EXISTING
COVERED
BOARDING AREA
EXISTING
HANDRAIL
PROPOSED
CONCRETE
EXISTING TREE
TO REMAIN
PROPOSED
CONCRETE
SID
EWALK
INSTALL 6" X 2" SADDLE SLEEVE WITH 2" GATE
VALVE (SEE DETAIL ON SHEET C05)
INSTALL 8" X 6" REDUCING WYE FOR
GRAVITY SEWER CONNECTION
APPROX. INV. = 64.62
(SEE DETAIL ON SHEET C05)
PROPOSED 2"
WATER SERVICE
PROPOSED 6"
GRAVITY SEWER
PROPOSED RESTROOMS
AND KIOSK BUILDING
F.F.E. = 69.00
2" FIRE PROTECTION
CONNECTION POINT TO BUILDING.
(SEE ARCHITECTURAL PLANS)
PROPOSED HANDRAIL
(TO MATCH EXISTING)
PROPOSED WALL
(SEE DETAIL ON SHEET C05)
SANITARY C/O
INV. EL.: 64.96
TREE
CANOPY
(APPROX.)
SAN
INV. EL.: 65.26
DOUBLE SWEEP
SANITARY C/O
INV. EL.: 64.65
105 LF OF 6" PVC @ 0.61%
SANITARY C/O
INV. EL.: 65.23
CAUTION:
EXISTING ELECTRICAL CONDUITS 3 FT DEEP
TO BE PROTECTED DURING CONSTRUCTION
13.7'
5.7'
4.6'
6.5'
R10.0'
.0'
6.3'
.4
PRUNE TREE AS NEEDED
4.
0'
EXISTING 6" WATER MAIN (APPROXIMATE)
CONTRACTOR TO VERIFY LOCATION AND
PROTECT FROM DAMAGES DURING
CONSTRUCTION
REPLACE SIDEWALK PANEL
TO THE NEXT JOINT LINE
SANITARY C/O
INV. EL.: 65.17
4.3'
8.4'
.2'
14.2'
3.8
4.0'
.5'
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
E E
E E
E E
E E
E E
E E
E
E E
E E
E E
E E
E E
E E
E
MATCH
EXISTING
MATCH
EXISTING
MATCH
EXISTING
MATCH
EXISTING MATCH
EXISTING
MATCH
EXISTING
68.84
67.99
68.78
68.89
68.90
68.90
68.90
68.90
68.90
PROPOSED RESTROOMS
AND KIOSK BUILDING
F.F.E. = 69.00
68.90
68.87
69.08 69.08
68.86
68.81
REGRADE GRASS ISLAND
AS NEEDED.TIE DOWN
GRADING SHALL NOT
EXCEED A SLOPE OF 4:1
68.78
67.75
68.74
67.61
67.40
68.74
68.53 68.62
68.8168.71
68.03
68.2967.61
67.55
68.90
68.90
68.90
68.90
68.90
68.90
68.84
67.10
67.26 67.48
67.54
67.60
67.55
67.18
67.68
68.03 68.07
68.52
MATCH
EXISTING
MATCH
EXISTING
68.07
68.01
66.65
67.24
66.39
67.03
INV. OUT EL.: 67.4
INV. OUT EL.: 67.6
YARD DRAIN
GRATE: 68.80
INV. OUT: 68.00
6" PVC @ 0.5%
6" PVC @ 0.5%
C/O INV. EL.: 67.68
W W
W .K
IM
LE
Y- H
O R
N .C
IS
TR
Y
N O
. 3
S E
TH
S
TR
EE
T, S U
IT
E
0, O C
AL
A, F
LO
R
ID
A
PH
O
N E:
-4
-3
SU
N
TR
AN
R
ES
TR
O
O M
S
AN
D K
IO
SK
PR
EP
AR
ED
F O
R
C
IT
Y O
F O
C
AL
A
LA
YO
U T
AN
D
G R
AD
IN
G P
LA
N
C03
NORTH
- INSTALL 2" WATER SERVICE LINE AND CONNECT TO EXISTING PIPE AS SHOWN. INSTALL 1-1/2" WATER
METER, BACK FLOW PREVENTER AND ISOLATION VALVE AS SHOWN. SEE ARCHITECTURAL PLAN.
- INSTALL 2" FIRE LINE WITH 2" DOUBLE DETECTOR CHECK VALVE WITH ISOLATION VALVE AND
CONNECT TO BUILDING AS SHOWN. SEE ARCHITECTURAL PLAN.
- INSTALL 6" PVC SANITARY SERVICE PIPE WITH CLEANOUTS AND CONNECT TO EXISTING AS SHOWN.
- CONSTRUCT 460 SF RESTROOMS AND KIOSK BUILDING. SEE ARCHITECTURAL PLAN.
- CONSTRUCT RETAINING WALL PER DETAIL ON SHEET C05.
- CONSTRUCT CONCRETE SIDEWALK PER DETAIL ON SHEET C05.
- CONSTRUCT ASPHALT PAVEMENT PER DETAIL ON SHEET C05.
- INSTALL BRONZE HANDRAIL TO MATCH EXISTING.
- WHITE PARKING STRIPE TO MATCH EXISTING.
- SOD ANY DISTURBED AREAS PER GENERAL NOTE #10 SHEET C01.
- ADA RAMP AND HANDRAIL IN COMPLIANCE WITH LATEST ADA DESIGN STANDARDS
(PER FDOT INDEX 515-062)
- ADA ACCESSIBLE CURB RAMP AND DETECTABLE WARNING STRIP
(PER FDOT INDEX NO. 522-002)
- PRIVATE ACCESS GATE TO MATCHED EXISTING FENCE
- ROOF DRAINS TO CONNECT TO 6" DRAINAGE PVC PIPE UNDERGROUND
- INSTALL TEMPORARY BARRIER FENCE DURING CONSTRUCTION TO SEPARATE THE PUBLIC AND
ONGOING CONSTRUCTION ACTIVITY
IT IS THE SURVEYOR'S AND CONTRACTOR'S
RESPONSIBILITY TO HAVE THE MOST CURRENT
PLANS DURING CONSTRUCTION. CONTACT PROJECT
ENGINEER, PRIOR TO LAYOUT OF IMPROVEMENTS,
TO OBTAIN COORDINATE DATA.
- GATE VALVE
- PROPOSED WATER LINEH2O
LEGEND
- FIRE LINE DOUBLE CHECK DETECTOR
- PROPOSED SANITARY SEWER PIPESS
- WATER METER AND REDUCED PRESSURE
BACKFLOW PREVENTOR
NORTH
LEGEND
100.00
- EXISTING CONTOURS
- PROPOSED CONTOURS
- PROPOSED FLOW DIRECTION ARROWS
- PROPOSED SPOT ELEVATION
PAVEMENT LEGEND
- ASPHALT PAVEMENT
(SEE DETAIL SHEET C05)
- CONCRETE PAVEMENT
(SEE DETAILS SHEET C05)
100.00 - EXISTING SPOT ELEVATION
1. CROSS SLOPES FOR NEW SIDEWALK SHALL NOT EXCEED 2.0%
2. LONGITUDINAL SLOPES FOR NEW SIDEWALK SHALL NOT EXCEED 5.0%
3. IF THERE IS AN AREA WHERE ITEMS 1 AND 2 ABOVE CANNOT BE MET, INFORM THE
ENGINEER FOR FUTURE COORDINATION.
4. THE SIDEWALK SLOPES WILL BE MEASURED BY THE ENGINEER AND THE CITY FOR
COMPLIANCE.
- SOD AREA AND FINISH TO
MATCH EXISTING
ALL NOTES LISTED BELOW SHALL BE CONSTRUCTED BY THE
CONSTRUCTION NOTES:
SITE CONTRACTOR, UNLESS STATED OTHERWISE.
IMPERATIVE:
LAYOUT PLAN
GRADING PLAN
GRADING NOTES:
7 6
SEWER AND WATER DEMAND:
1. ESTIMATED DOMESTIC SEWER DEMAND:
96 USERS PER DAY X 4 GALLONS = 384 G.P.D.
2. ESTIMATED POTABLE WATER DEMAND:
384 G.P.D. X 1.2 = 461 G.P.D.
SPLM24-45592-Suntran Union
W .K
IM
LE
Y- H
O R
N .C
IS
TR
Y
N O
. 3
S E
TH
S
TR
EE
T, S U
IT
E
0, O C
AL
A, F
LO
R
ID
A
PH
O
N E:
-4
-3
SU
N
TR
AN
R
ES
TR
O
O M
S
AN
D K
IO
SK
PR
EP
AR
ED
F O
R
C
IT
Y O
F O
C
AL
A
ST
O
R M
W
AT
ER
PO
LL
U
TI
O
N
PR
EV
EN
TI
O
N P
LA
N
C04
1. DISCHARGE CONTROL AND EROSION PROTECTION MEASURES SHALL BE EMPLOYED AND OPERATED AT ALL TIMES DURING CONSTRUCTION TO AVOID ADVERSE IMPACTS TO RECEIVING WATERS OR ADJACENT PROPERTY. DETENTION.RETENTION STORAGE STRUCTURES, SEDIMENT BARRIERS, FLOW CONVEYANCES, REVETMENT, DISCHARGE CONTROL STRUCTURES, AND OTHER STORMWATER MANAGEMENT STRUCTURES SHOULD BE BUILT AND CONTINUOUSLY MAINTAINED DURING PROJECT CONSTRUCTION IN A MANNER SUCH THAT, TO THE EXTENT POSSIBLE, THE STRUCTURES ARE INCORPORATED INTO AND BECOME PART OF THE PERMANENT SURFACE
WATER MANAGEMENT SYSTEM.
2. THE OWNER/PERMITTEE SHALL ENSURE THAT THE SURFACE WATER AND STORMWATER MANAGEMENT MEASURES PROPOSED IN THE PLAN ARE EFFECTIVELY IMPLEMENTED UNTIL COMPLETION OF THE PROJECT OR UNTIL THE PERMANENT SURFACE WATER MANAGEMENT SYSTEM IS OPERATIONAL.
3. THE SITE SHALL REMAIN FREE OF EXCESS DUST AND DEBRIS AT ALL TIMES. ANY INCIDENCE OF EROSION, SEDIMENTATION, DUST OR DEBRIS OCCURRING OFF-SITE AS A RESULT OF CONSTRUCTION ACTIVITIES ON THIS DEVELOPMENT SHALL BE CORRECTED BY THE CONTRACTOR IMMEDIATELY (FOR EACH OCCURRENCE).
4. ALL STORM WATER MANAGEMENT SYSTEMS SHALL BE COMPLETED PRIOR TO CONSTRUCTION OF IMPERVIOUS AREAS.
5. SILT FENCE, STRAW BALE INLET FILTERS, AND ANY OTHER EROSION/SEDIMENTATION PROTECTION SHOWN ON THESE PLANS SHALL BE INSTALLED IMMEDIATELY FOLLOWING SITE CLEARING AND PRIOR TO ANY SITE DEVELOPMENT. ALL EROSION/SEDIMENTATION PROTECTION SHALL BE MAINTAINED DURING THE LIFE OF THE
CONSTRUCTION PROJECT AND REMOVED AFTER COMPLETION.
6. CONSTRUCTION WASTE - WASTE SHALL BE COLLECTED AT A DESIGNATED AREA ONSITE. ADEQUATE NUMBER OF CONTAINERS SHALL BE PROVIDED (WHEN POSSIBLE COVER CONTAINERS OR PROVIDE LIDS ON CONTAINERS). ARRANGE FOR WASTE COLLECTION BEFORE CONTAINERS OVERFLOW, PROVIDE CLEAN UP IMMEDIATELY IF
SPILLAGE OCCURS.
7. CONTROL AND DISPOSAL OF WASTES - CONTRACTOR SHALL DEVELOP AND IMPLEMENT A PLAN TO ASSURE THAT ALL WASTE, SUCH AS DISCARDED BUILDING MATERIALS, CONCRETE TRUCK WASH-OUT, CHEMICALS, LITTER AND SANITARY WASTE, ARE PROPERLY CONTROLLED WHILE ON-SITE AND TRANSPORTED AND DISPOSED OF (OFF-SITE) IN ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND FEDERAL REGULATIONS. NO WASTE MATERIALS OF ANY KIND ARE PERMITTED TO BE BURIED ON-SITE OR DISCHARGED TO SURFACE WATERS OF THE STATE OR TO THE CITY'S STORM WATER SYSTEM.
8. CONCRETE TRUCKS - EMPTYING OR WASH OUT OF EXCESS CONCRETE MAY BE ALLOWED ONSITE. EXCESS CONCRETE AND WASH WATER SHOULD BE DISPOSED OF IN A MANNER THAT PREVENTS CONTACT BETWEEN THESE MATERIALS AND STORMWATER WHICH WILL BE DISCHARGED FROM THE SITE. FOR EXAMPLE, DIKES COULD BE CONSTRUCTED AROUND THE AREA TO CONTAIN THESE MATERIALS UNTIL THEY HARDEN, AT WHICH TIME THEY MAY BE PROPERLY DISPOSED OF.
9. CONTRACTOR SHALL PERIODICALLY SWEEP ALL EXISTING ON-SITE PAVED SURFACES AND OFF-SITE ABUTTING CITY STREETS AND STATE HIGHWAYS AS NEEDED TO KEEP THOSE SURFACES IN A SEDIMENT-FREE CONDITION. SWEEPING SHALL BE DONE BY MECHANICAL MEANS, WITH WATER SUPPLEMENT, ON A REGULAR BASIS SEVERAL TIMES A WEEK INCLUDING, MOST PARTICULARLY, AFTER EVERY RAIN EVENT AND EVERY FRIDAY AFTERNOON PRIOR TO CEASING WORK FOR THE WEEK.
10. SANITARY/SEPTIC DISPOSAL - DOMESTIC WASTE HAULERS SHOULD BE CONTRACTED TO REGULARLY REMOVE THE SANITARY AND SEPTIC WASTES AND TO MAINTAIN
THE FACILITIES IN GOOD WORKING ORDER.
11. PETROLEUM PRODUCTS - OIL, GASOLINE, LUBRICANTS, AND ASPHALTIC SUBSTANCES SUCH AS PAVING MATERIALS SHOULD BE HANDLED CAREFULLY TO MINIMIZE THEIR EXPOSURE TO STORM WATER. EQUIPMENT SHOULD BE ON SITE TO CONTAIN AND CLEAN UP PETROLEUM SPILL IN FUEL STORAGE AREAS OR ON BOARD MAINTENANCE AND FUELING VEHICLES. CONTAIN AND CLEAN UP PETROLEUM SPILLS IMMEDIATELY.
12. HAZARDOUS PRODUCTS - THESE PRODUCTS SHALL BE USED IN A SAFE MANNER TO AVOID POLLUTION OF STORM WATER. EQUIPMENT SHOULD BE ONSITE TO CONTAIN AND CLEAN UP SPILLS OF HAZARDOUS MATERIALS IN THE AREAS WHERE THESE MATERIALS ARE STORED OR USED. CONTAIN AND CLEAN UP SPILLS IMMEDIATELY
AFTER THEY OCCUR.
13. NON-STORM WATER DISCHARGES - THESE DISCHARGES INCLUDE BUT NOT LIMITED TO: FIRE HYDRANT FLUSHINGS, POTABLE WATER SOURCES (FLUSHING), IRRIGATION, BUILDING WASHDOWN, AND AIR CONDITIONING CONDENSATION. PRIOR TO ANY DISCHARGE, ALL DOWNSLOPE SITE SEDIMENTATION AND EROSION CONTROLS SHOULD BE IN PLACE. DISCHARGE SHOULD ONLY BE DIRECTED TO AREAS THAT ARE STABILIZED TO MINIMIZE EROSION (E.G., BUFFER ZONE, VEGETATED FILTER STRIPES, INLET AND OUTLET PROTECTION, LEVEL SPREADERS, ETC.) DO NOT DISCHARGE NON-STORM WATER FLOWS ONTO DISTURBED AREAS.
14. A STORMWATER POLLUTION PREVENTION PLAN INSPECTION REPORT IS REQUIRED AT LEAST ONCE A WEEK AND WITHIN 24 HOURS OF THE END OF A STORM EVENT THAT IS 0.5 INCHES OR GREATER. THE REPORTS ARE TO BE FILED AT THE PROJECT SITE WITH THE STORM WATER POLLUTION PREVENTION PLAN.
STORMWATER POLLUTION PREVENTION PLAN (S.W.P.P.P.) NOTES:
I CERTIFY UNDER PENALTY OF LAW THAT I UNDERSTAND, AND SHALL COMPLY WITH, THE
TERMS AND CONDITIONS OF THE STATE OF FLORIDA GENERIC PERMIT FOR STORMWATER
DISCHARGE FROM LARGE AND SMALL CONSTRUCTION ACTIVITIES AND THIS STORMWATER
POLLUTION PREVENTION PLAN PREPARED THEREUNDER.
THE STORMWATER MANAGEMENT MEASURES PROPOSED ON THIS PLAN SHALL
BE EFFECTIVELY IMPLEMENTED AND MAINTAINED UNTIL COMPLETION OF THE
PROJECT OR UNTIL THE PERMANENT SURFACE WATER MANAGEMENT SYSTEM
IS OPERATIONAL
N.T.S.
DROP INLET SEDIMENT FILTER DETAIL
SECTION A-A
NOTES:
1. DROP INLET SEDIMENT BARRIERS ARE TO BE USED FOR SMALL NEARLY LEVEL DRAINAGE
ARES. (LESS THAN 5%).
2. USE 2"X4" WOOD OR EQUIVALENT METAL STAKES (3 FT. MIN. LENGTH).
3. INSTALL 2"X4" WOOD FRAME TO INSURE STABILITY.
4. SEE EROSION CONTROL PLAN FOR LOCATIONS AND APPLICABILITY.
SILT FENCE
A MINIMUM OF 12" OF
SILT FENCE MUST BE
BURIED IN TRENCH
A
A
TOP FRAME NECESSARY
FOR STABILITY
ATTACH FILTER FABRIC SECURILTY
TO 2X4 WOOD FRAME, OVERLAPPING
FABRIC TO NEXT STAKE
2"X4" WOOD FRAME
4 SIDES OF DROP INLET
FILTERED
WATER
OPTION 1 SILT FENCE BARRIER
WRAP GRATE, TOP
AND BOTTOM WITH
GEOTEXTILE FABRIC
OPTION 2 GRAVEL AND WIRE MESH FILTER
FILTERED
WATER
2"WIRE MESH
FDOT NO. 1 COARSE AGGREGATE
(12" MIN. DEPTH)
RUNOFF WATER
RUNOFF
WATER
NOTES:
1. DIMENSIONS OF SEDIMENT FILTER
DETAILS MAY BE ADJUSTED FOR
TYPE "9" CURB INLET TOPS.
2. PRE-MANUFACTURED INLET SOCK MAY BE
SUBSTITUTED IF APPROVED BY THE ENGINEER.
3. SEE EROSION CONTROL PLAN FOR
LOCATION AND APPLICABILITY.
SAND BAG
(TYP.)
2' X 12' FDOT NO 1
COARSE AGGREGATE FILTER
RUNOFF
WATER
RUNOFF
WATER
FDOT NO. 1 COARSE
AGGREGATE FILTER
UNDERDRAIN
TO FULLY
COVER INLET
THROAT
8" PERFORATED UNDERDRAIN
COVERED WITH FILTER SOCK
IRON
GRATE
8" PERFORATED UNDERDRAIN
COVERED WITH FILTER SOCK
SAND BAG
(TYP.)
RUNOFF
WATER
2" WIRE
MESH
FILTERED
WATER
CURB INLET SEDIMENT FILTER DETAIL
N.T.S.
FILTERED WATER
A
A
OPTION 1 UNDERDRAIN FILTER
SECTION A-A
OPTION 2 GRAVEL AND WIRE MESH
B
B
SECTION B-B
NORTH
SPLM24-45592-Suntran Union
W .K
IM
LE
Y- H
O R
N .C
IS
TR
Y
N O
. 3
S E
TH
S
TR
EE
T, S U
IT
E
0, O C
AL
A, F
LO
R
ID
A
PH
O
N E:
-4
-3
SU
N
TR
AN
R
ES
TR
O
O M
S
AN
D K
IO
SK
PR
EP
AR
ED
F O
R
C
IT
Y O
F O
C
AL
A
C O
N
ST
R U
C
TI
O N
D
ET
AI
LS
C05
SIDEWALK SHALL BE CONSTRUCTED PER FDOT INDEX NO. 522-001.
TYPICAL SIDEWALK SECTION
5' MIN. CONCRETE WALK
1% STD. 2% MAX.
6"x6"-W1.4xW1.4 WELDED
WIRE MESH @ MID-LAYER
COMPACT TO ACHIEVE
UNYIELDING SURFACE
3000 PSI CONCRETE
4" THICK
NOTE: SEE SITE PLAN FOR SPECIFIC SIDEWALK LOCATIONS
TYPICAL STANDARD DUTY
PAVEMENT SECTION
WALL DETAIL
SPLM24-45592-Suntran Union
SPLM24-45592-Suntran Union
| C01 COVER SHEET |
| C01 COVER SHEET |
| C01.1 MASTER LAYOUT |
| MASTER LAYOUT |
| C02 DEMOLITION PLAN |
| C02 DEMOLITION PLAN |
| C03 LAYOUT AND GRADING PLAN |
| C03 LAYOUT AND GRADING |
| C04 STORMWATER POLLUTION PREVENTION PLAN |
| C04 STORMWATER POLLUTION PREVENTION PLAN |
| C05 CONSTRUCTION DETAILS |
| C05 CONSTRUCTION DETAILS |
S01 Survey