This document is an Invitation to Bid (ITB) issued by the City of Salem, Virginia for the renovation and expansion of the Jury Room in the City Courthouse located at 2 E Calhoun Street, Salem, VA. The ITB seeks qualified contractors to provide all labor, materials, and equipment needed for this project. The project overview includes details on the scope of work, location, and timeline. Sealed bids are due by a specific date and time, and a mandatory site visit is scheduled. The contract is expected to be awarded within a specified timeframe following the bid due date. No additional contract term or renewal options are provided.
The ITB outlines the pricing and evaluation criteria for the bids, including any applicable set-asides. However, details on the current incumbent, funding sources and requirements, or other salient financial information are not included in this document.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CITY OF SALEM
PURCHASING DEPARTMENT
114 NORTH BROAD STREET
P.O. BOX 869
SALEM, VA 24153
PHONE (540) 375-3063 FAX (540) 375-4057
DATE: NOVEMBER 7, 2023
BIDS WILL BE RECEIVED BY THE CITY OF SALEM IN THE PURCHASING DEPARTMENT, LOCATED AT 114 NORTH BROAD STREET, P.O. BOX 869, SALEM, VIRGINIA 24153. ANY QUESTIONS CONCERNING THIS INVITATION TO BID (ITB) SHOULD BE DIRECTED TO MICHELLE BRAXTON, PURCHASING MANAGER AT
(540) 375-3063 OR BY EMAIL AT LMBRAXTON@SALEMVA.GOV.
INVITATION TO BID #: 2024-011
BID DESCRIPTION: CITY OF SALEM COURTHOUSE - JURY ROOM EXPANSION
DATE AND TIME BID DUE: DECEMBER 13, 2023 AT 3:00 P.M.
TO BE CONSIDERED, RETURN ONE (1) ORIGINAL AND THREE (3) COPIES, IN A SEALED ENVELOPE, CLEARLY MARKED “ATTN:
PURCHASING DEPARTMENT - ITB # 2024-011 – CITY OF SALEM COURTHOUSE - JURY ROOM EXPANSION” WITH YOUR COMPANY NAME
AND THE DATE/TIME BID IS DUE. ANY BID RECEIVED AFTER THE ABOVE DATE AND TIME FOR SUBMITTAL, WHETHER BY MAIL OR OTHERWISE, WILL BE REJECTED AND SUCH BID SHALL BE RETURNED TO THE BIDDER UNOPENED. FAXED OR EMAILED BIDS ARE NOT ACCEPTABLE.
AWARD WILL BE MADE IN THE BEST INTEREST OF THE CITY OF SALEM, THE CITY RESERVES THE RIGHT TO REJECT ANY OR ALL BIDS, TO WAIVE INFORMALITIES, AND TO PURCHASE ANY PART OF, OR THE WHOLE OF, THE ITEMS AND/OR SERVICES LISTED IN THIS INVITATION TO BID.
NO BID MAY BE WITHDRAWN AFTER OPENING EXCEPT FOR CLERICAL ERRORS, AS SET FORTH IN SECTION 2.2-4330 OF THE VIRGINIA CODE. BIDDER MUST
GIVE THE CITY A NOTICE IN WRITING OF THE REQUEST TO WITHDRAW A BID WITHIN TWO (2) BUSINESS DAYS AFTER THE CONCLUSION OF THE BID OPENING.
ALL BIDS SHALL BE F.O.B. SALEM, VIRGINIA, AND SHALL INCLUDE THE EARLIEST DELIVERY DATE.
THE CITY OF SALEM WILL FURNISH A TAX EXEMPTION CERTIFICATE, AND NO BID SHALL INCLUDE ANY FEDERAL OR STATE TAXES.
TERMS ARE NET 30 UNLESS OTHERWISE STATED IN THIS INVITATION TO BID.
THE CITY OF SALEM DOES NOT DISCRIMINATE AGAINST FAITH BASED ORGANIZATIONS.
DATE:
LEGAL NAME OF BUSINESS (PRINT):
ADDRESS:
AUTHORIZED SIGNATURE:
PRINT OR TYPE AUTHORIZED SIGNATURE NAME & TITLE:
PHONE NUMBER: FAX NUMBER:
EMAIL ADDRESS:
VA CONTRACTOR’S LICENSE #:
VIRGINIA STATE CORPORATION COMMISSION (SCC) ID #:
BUSINESS LICENSE #:
BY SIGNING THIS INVITATION TO BID (ITB), THE BIDDER ACKNOWLEDGES THAT HE/SHE FULLY UNDERSTANDS THIS ITB AND
THAT IT MEETS OR EXCEEDS ALL SPECIFICATIONS LISTED OR REFERENCED.
mailto:lmbraxton@salemva.gov
ITB # 2024-011
CITY OF SALEM COURTHOUSE - JURY ROOM EXPANSION
I. GENERAL INFORMATION:
The City of Salem, Virginia, is requesting sealed bids from qualified Contractors for all labor, materials, and equipment needed for the renovation and expansion of the Jury Room in the City Courthouse, located at 2 E Calhoun Street, Salem, VA, in accordance with Invitation to Bid (ITB) # 2024-011.
There will be a non-mandatory pre-bid meeting at 10:00 a.m. on November 15, 2023, in the Jury Room in the City Courthouse, located at located at 2 E Calhoun Street, Salem, Virginia, 24153, to answer any questions from interested parties.
There will also be a non-mandatory site visit at 10:00 a.m. on November 16, 2023 for Bidders who were unable to attend the pre-bid meeting and/or to re-visit the site. There will be no questions answered at the site visit.
Bidders are strongly encouraged to attend the pre-bid meeting and/or site visit to review existing conditions prior to submitting a bid on this project.
Project plans may be obtained by email to: lmbraxton@salemva.gov or from City of Salem’s Purchasing Website at: https://salemva.gov/220/Purchasing
This Invitation to Bid consists of the following (including any Addendums that the City may issue). Each Bidder should carefully read and review ALL documents:
1. All Sections of Invitation to Bid # 2024-011
2. Summary of Work/Project Drawings (Attachment A)
3. General and Supplemental Conditions (Attachment B)
4. Bid Form (Attachment C)
5. Bid Bond (Attachment D)
6. Supplemental Terms and Conditions (Attachment E)
There will be liquidated damages as specified in General and Supplemental Conditions, Section 14, Changes in Contract Price, Completion and Liquidated Damages.
The City of Salem invites any qualified Bidder to respond to this ITB by submitting a Bid for such work, service, and/or items consistent with the terms and conditions herein set forth.
II. INSTRUCTIONS TO BIDDERS:
A. Sealed Bids shall be received by Michelle Braxton of the City of Salem Purchasing Department, 114 North Broad Street, Salem, VA 24153 by 3:00 p.m., on Wednesday, December 13, 2023. Bidders shall submit one (1) original and two (2) copies of their bid in a sealed envelope clearly marked on the outside with the company’s name and “Attn: Purchasing Department - ITB # 2024-011 – City of Salem Courthouse - Jury Room Expansion”. Any bids received after the mentioned time and date will be returned to the Bidder unopened. Faxed or emailed bids will not be accepted.
At this time, the contents of all bids will be read aloud and made public for the information of Bidders and other interested parties who may be present in person or by representative.
B. Each Bidder is solely responsible for ensuring that they have the current, complete version of the Bid documents, including any addendum(s), before submitting. The City is not responsible for any Bid documents obtained from any source other than the City.
C. Bid submittal shall include:
1. Bidder Acknowledgment & Data Sheet, Page 1 of this ITB
2. Bid Form (Attachment C), Page 64 of this ITB
3. Bid Bond (Attachment D), Page 65 of this ITB https://salemva.gov/220/Purchasing
D. For questions regarding this bid, please contact:
Michelle Braxton, Purchasing Manager P.O. Box 869
Salem, VA 24153 Telephone: 540-375-3063
Fax: 540-375-4057 Email: lmbraxton@salemva.gov
E. All questions and clarifications must be submitted by 3:00 p.m. on December 4, 2023.
F. All Bids must be signed by an authorized representative on the forms provided with this Bid. No changes are to be made to the Bid Form. Any changes to Bid amounts must be initialed.
G. The City’s procedures for withdrawal of bids (construction or other than construction) is that set forth in Section 2.2-4330 of the Virginia Code.
H. Each Bidder is advised that the Ethics in Public Contracting and Conflicts of Interests Act of the Code of Virginia applies to this Bid. Such information should be provided with the Bid response.
I. Failure to submit all required pages and information may result in the Bid to be non-responsive.
J. It is the sole responsibility of the Bidder for any cost incurred in the preparation and submission of this Bid.
K. A Bidder organized as a stock or non-stock corporation, limited company, business trust or limited partnership or registered as a registered limited liability partnership shall be authorized to transact business in the Commonwealth as a domestic or foreign business entity if so required by Title 13.1 or Title 50 of the Code of Virginia or as otherwise required by law. Any business entity described herein that enters into a Contract with the City pursuant to the Virginia Public Procurement Act 2.2-4300 et seq. shall not allow its existence to lapse or its certificate of authority or registration to transact business in the Commonwealth, if so required under Title 13.1 or Title 50 of the Code of Virginia, to be revoked or cancelled at any time during the term of the Contract. The City may void any Contract with a business entity if the business entity fails to remain in compliance with the provisions of this section. Please contact the SCC to determine whether your firm should register.
L. BID GUARANTEE: Each bid must be accompanied by a bid guarantee which shall be not less than five percent (5%) of the largest amount of which BID is made and, at the option of the bidder, may be a certified check, bank draft, or bid bond. No bid will be considered unless it is so guaranteed. Certified check or bank draft shall be made payable to the City of Salem. Cash deposits will not be accepted. The bid guarantee shall insure the execution of the contract and the furnishing of performance and payment bonds by the successful bidder as required by the specifications.
M. MODIFICATION; WITHDRAWAL OF BIDS: In accordance with withdrawal due to error in the bid, as specified in the latest edition of the City of Salem Purchasing Policy and Procedures Manual.
N. REJECTION OF BIDS: The City of Salem reserves the right to reject any or all bids and to waive any informality in bids received whenever such rejection or waiver is in the interest of the City of Salem.
O. QUALIFICATIONS REQUIRED: The ability of any bidder to obtain a performance bond shall be regarded as a test of such bidder's competency or responsibility. Any bidder must be prepared to present evidence of experience, ability and financial standing as well as an inventory of plant and equipment.
The Successful Bidder must have a valid Virginia Class A Contractors License and must demonstrate at least 5 years of experience with similar projects.
P. PERFORMANCE/PAYMENT BONDS: The bidder must be able to obtain a performance bond and payment bond in the amount of 100% of the bid estimate. This bond can be in the form of Letter of credit, Bank Insurance, or cash. Failure to obtain the performance bond will result in disqualification of the bid.
III. STATEMENT OF NEEDS/SPECIFICATIONS:
Please refer to Attachment A, Summary of Work/Project Drawings.
IV. CONTRACT TIME:
WORK under this Agreement shall achieve Substantial Completion no later than Two Hundred Forty (240) consecutive calendar days after the commencement date given in a Notice to Proceed provided by the City to the Contractor, subject to any modifications made as provided for in the Contract Documents. This Two Hundred Forty (240) day period shall be the Period of Performance for Substantial Completion. No Work shall be deemed Substantially Complete until it meets the requirements of Substantial Completion as set forth in the General and Supplemental Conditions. Final Completion of the Work shall be completed no later than Thirty (30) calendar days after the date of acceptance of Substantial Completion by the City of Salem Project Representative. Work will not reach Final Completion until it meets the requirements set forth in the General and Supplemental Conditions. Unless otherwise provided, no claims for early completion are allowed
V. SUCCESSFUL BIDDER’S RESPONSIBILITY:
The Successful Bidder shall be responsible for the work to be done by any subcontractor(s) and shall assure compliance with all requirements of this Contract. The Successful Bidder shall be responsible for completely supervising and directing the work under this contract and all subcontractors that may be utilized.
Subcontractor(s) who perform work under this Contract shall be responsible to the Successful Bidder. The Successful Bidder shall, however, remain fully liable and responsible for the work to be done by their subcontractor(s).
REMAINDER OF PAGE INTENTIONALLY LEFT BLANK
ATTACHMENT A
SUMMARY OF WORK/PROJECT DRAWINGS
Reference the following pages for plans provided by Balzer & Associates Inc., dated August 30, 2023. Technical specifications are directly on the drawings, therefore, there is NO project manual.
REMAINDER OF PAGE INTENTIONALLY LEFT BLANK
GENERAL WALL SECTION NOTES
1. ALL DATUM ELEVATIONS ARE INDICATED
RELATIVE TO HEIGHT ABOVE MAIN BUILDING
SLAB OR FRAMED FLOOR SYSTEMS. REFER
TO CIVIL DRAWINGS FOR TOP OF SLAB
ELEVATION.
2. REFER TO STRUCTURAL SHEETS FOR ALL
SLAB AND FOUNDATION DESIGN FACTORS,
DIMENSIONS, NOTES, REINFORCING, AND
DEFLECTION CRITERIA.
3. COORDINATE EXTERIOR FINISHES AND
DESCRIPTIONS WITH ADDITIONAL NOTES ON
EXTERIOR ELEVATIONS.
4. ALL INTERIOR FINISH SURFACES (FLOORS,
WALLS, AND CEILINGS) SHALL BE
COORDINATED WITH FINISH SCHEDULES,
FLOOR FINISH PLANS, AND REFLECTED
CEILING PLANS.
5. ALL TRANSITIONAL FLASHING REQUIRED AT
ROOF EAVE/PARAPET TRANSITIONS SHALL
BE INSTALLED AS RECOMMENDED BY
MANUFACTURERS OF ADJACENT MATERIALS
WITH APPROVED AND CHEMICALLY
COMPATIBLE SEALANTS.
6. REFER TO ROOF PLAN FOR ALL SLOPES.
7. REFER TO CODE REVIEW DATA FOR
REQUIRED INSULATION MINIMUM VALUES
(UNDER-SLAB, WALLS, AND ROOF).
8. PROVIDE AND INSTALL SEALANTS AND/OR
EXPANSION FILLER AT ALL DISSIMILAR
MATERIALS. INSTALL WITH BACKER RODS
PER MANUFACTURER RECOMMENDATIONS.
GENERAL BUILDING SECTION NOTES
1. ALL DATUM ELEVATIONS ARE INDICATED
RELATIVE TO HEIGHT ABOVE BUILDING SLAB
OR FRAMED FLOOR SYSTEMS. REFER TO
CIVIL DRAWINGS FOR TOP OF SLAB
ELEVATION.
2. REFER TO STRUCTURAL SHEETS FOR ALL
SLAB AND FOUNDATION DESIGN FACTORS,
DIMENSIONS, NOTES, REINFORCING, AND
DEFLECTION CRITERIA.
3. COORDINATE ALL MATERIALS/SYSTEMS WITH
THOSE NOTED ON FLOOR PLANS, EXTERIOR
ELEVATIONS, WALL SECTIONS, AND
SCHEDULES.
4. COORDINATE ALL EXTERIOR WALL
PENETRATIONS WITH OTHER TRADES.
5. GRADING CONDITIONS AT THE BUILDING
FACE MAY VARY AS SITE CONDITIONS AND
BUILDING TECHNIQUES MAY DICTATE.
6. REFER TO CODE REVIEW DATA FOR
REQUIRED INSULATION MINIMUM VALUES
(UNDER-SLAB, WALLS, AND ROOF).
GENERAL EXTERIOR ELEVATION NOTES
1. COORDINATE ALL EXTERIOR WALL
PENETRATIONS WITH OTHER TRADES.
2. GRADING CONDITIONS AT THE BUILDING
FACE MAY VARY AS SITE CONDITIONS AND
BUILDING TECHNIQUES MAY DICTATE.
3. EXTERIOR WALL PLUMBING AND VENTILATION
PENETRATIONS ARE NOT SHOWN.
COORDINATE PROPOSED LOCATIONS WITH
OWNER PRIOR TO INSTALLATION.
4. ALL EXTERIOR FINISHES/COLORS/TEXTURES
AND/OR MANUFACTURERS SHOWN HEREIN
SHALL BE VERIFIED WITH OWNER PRIOR TO
CONSTRUCTION.
GENERAL EXTERIOR MASONRY NOTES (BRICK)
1. ALL EXTERIOR FINISHES/COLORS/TEXTURES
AND/OR MANUFACTURERS SHOWN HEREIN
SHALL BE VERIFIED WITH OWNER PRIOR TO
CONSTRUCTION.
2. PROVIDE VERTICAL CONTROL JOINTS IN
BRICK VENEER AT LOCATIONS SHOWN
AND/OR AT SPACING NOTED IN OUTLINE
SPECIFICATIONS, TO BE LOCATED AT ENDS
OF WINDOW/DOOR LINTELS WHERE
POSSIBLE.
3. ALL VERTICAL MASONRY DIMENSIONS,
MORTAR JOINTS SHALL BE ALIGNED WITH
BUILDING FINISHED FLOOR.
4. SEALANTS USED IN CONTROL JOINTS SHALL
MATCH MORTAR COLORS; SEALANTS USED
AROUND DOOR AND WINDOW OPENINGS
SHALL MATCH DOOR OR WINDOW FRAMES.
5. REFER TO EXTERIOR ELEVATIONS FOR
PROJECTIONS, COURSING, AND BANDING.
GENERAL EXTERIOR PAINT NOTES
1. ALL EXTERIOR FINISHES/COLORS/TEXTURES
AND/OR MANUFACTURERS SHOWN HEREIN
SHALL BE VERIFIED WITH OWNER PRIOR TO
CONSTRUCTION.
2. PAINTING SHALL BE LABELED FOR EXTERIOR
APPLICATIONS. USE ONLY PAINT LISTED BY
MANUFACTURER FOR INTENDED
SUBSTRATES.
3. PAINT ALL EXTERIOR SIDING, TRIM AND
SOFFITS. CONSULT OWNER FOR ALL
REQUIRED PAINT AND MATERIAL COLORS IF
NOT SPECIFICALLY SHOWN HEREIN.
4. MASK ANY EXTERIOR ELEMENTS (LIGHTS,
WINDOWS, DOORS, AND SIMILAR OBJECTS)
WHICH ARE NOT TO BE PAINTED PRIOR TO
PAINTING. REMOVE ANY SPILLS OR EXCESS
PAINT BEFORE PAINT DRIES.
5. PAINT ALL EXPOSED UTILITY JUNCTION
BOXES/METERS AND ASSOCIATED CONDUIT
SHALL BE PAINTED TO MATCH IMMEDIATELY
ADJACENT BUILDING COLOR.
GENERAL ROOFING & GUTTERING NOTES
1. ALL EXTERIOR FINISHES/COLORS/TEXTURES
AND/OR MANUFACTURERS SHOWN HEREIN
SHALL BE VERIFIED WITH OWNER PRIOR TO
CONSTRUCTION.
2. CONNECT TO BELOW GRADE PIPING. SEE
SCHEMATIC ROOF PLAN FOR DOWNSPOUT
LOCATIONS. COLOR TO BE SELECTED BY
OWNER, TYPICAL.
GENERAL EXTERIOR BUILDING SIGNAGE NOTES
1. ALL EXTERIOR BUILDING SIGNAGE SHALL BE
UNDER A SEPARATE LOCALITY PERMIT.
COORDINATE/VERIFY LOCATIONS WITH
OWNER SPECIFICATIONS.
2. PROVIDE ELECTRICITY TO ALL EXTERIOR
SIGNAGE AS REQUESTED BY OWNER.
GENERAL CASEWORK/MILLWORK NOTES
1. THESE ARE SCHEMATIC CASEWORK
DRAWINGS. BALZER AND ASSOCIATES IS NOT
RESPONSIBLE FOR DIMENSIONING,
FABRICATION DETAILS (INCLUDING BRACING,
FASTENING, AND CONCEALED BLOCKING,
AND SIMILAR FRAMING) NORMALLY
ASSOCIATED WITH SHOP DRAWINGS.
2. ALLOW A MINIMUM OF 1 INCH CLEARANCE
FROM THE EDGE OF ALL WALLS AND THE
OUTSIDE FACE OF CASEWORK, TYPICAL
3. FILLER STRIPS ARE TO BE PROVIDED AT ALL
WALLS.
TOILET ACCESSORIES NOTES
1. GENERAL CONTRACTOR TO SUPPLY AND
INSTALL SCHEDULED TOILET ACCESSORIES
IN RESTROOMS. VERIFY IF OWNER OR
OWNER'S VENDOR IS SUPPLYING
SCHEDULED ACCESSORIES.
2. PROVIDE WOOD BLOCKING AT ALL WALL-
HUNG ITEMS IN FRAMED PARTITIONS.
3. ALL ACCESSORIES MUST BE ACCESSIBILITY
(ADA) COMPLIANT, SEE ADA REFERENCE
DETAILS SHEET.
4. VERIFY MOUNTING HEIGHT OF TOILET TISSUE
HOLDER PRIOR TO MOUNTING. HEIGHT MAY
VARY DEPENDING ON UNIT FURNISHED BY
OWNER.
5. GENERAL CONTRACTOR TO INSTALL BABY
CHANGING STATION AND RESTROOM WALL
CABINET (FURNISHED BY OWNER).
6. INSULATE ALL EXPOSED HOT WATER SUPPLY
AND DRAIN PIPES.
7. TOILET LEVER SHALL BE TO THE WIDE SIDE
OF ROOM OR STALL.
8. PROVIDE VENTILATION FAN TO OUTSIDE FOR
ALL TOILETS. OPERATION TO ACTIVATE
WHEN LIGHT IS SWITCHED.
9. GENERAL CONTRACTOR SHALL VERIFY FINAL
FIXTURE SELECTIONS WITH OWNER PRIOR
TO PURCHASING.
INTERIOR SIGNAGE NOTES
1. PROVIDE ACCESSIBILITY COMPLIANT
SIGNAGE TO ALL PUBLICLY ACCESSED AREAS
WITHIN THE BUILDING. THIS INCLUDES BUT IS
NOT LIMITED TO RESTROOMS, LOBBY AREAS,
AND MECHANICAL ROOMS.
2. VERIFY ADDITIONAL SIGNAGE
REQUIREMENTS WITH THE OWNER.
3. REFER TO CODE SUMMARY FOR ADDITIONAL
NOTES.
GENERAL STOREFRONT NOTES
1. STANDARD PROFILE STOREFRONT SYSTEMS
SHALL BE ANODIZED BRONZE FINISH,
TYPICAL.
2. REFER TO DOOR SCHEDULE FOR GLAZING
TYPES USED IN DOORS.
GENERAL DOOR NOTES
1. PROVIDE WEATHERSTRIPPING AND DOOR
SWEEPS AT ALL EXTERIOR DOORS.
2. FINAL DOOR STYLE SELECTIONS, COLOR,
AND HARDWARE ARE TO BE DETERMINED.
GENERAL CONTRACTOR SHALL VERIFY AND
COORDINATE IN THE FIELD.
3. HOLLOW METAL FRAMES SHALL BE 16 GAUGE
STEEL FOR EXTERIOR DOORS AND 18 GAUGE
FOR INTERIOR DOORS.
4. PROVIDE DOOR FRAMES WITH 4" HEADS AT
ALL DOORS WITHIN MASONRY WALLS AS
REQUIRED TO MAINTAIN COURSING.
5. ALL GLAZING IN DOORS AND WITHIN A 24"
ARC OF THE SIDES OF EGRESS DOORS
SHALL BE OF AN APPROVED SAFETY TYPE.
(VERIFY IN FIELD).
6. PAINT HOLLOW METAL FRAMES AND DOORS
WHERE SCHEDULED WITH 2 FINISH COATS OF
HIGH-GLOSS ACRYLIC ENAMEL. REFER TO
ELEVATIONS AND FINISH SCHEDULE.
7. ALL THRESHOLDS SHALL BE 1/4" MAXIMUM
OFFSET, ADA ACCESSIBLE.
8. DOOR DETAILS DO NOT DEPICT ALL INTERIOR
FINISHES. REFER TO INTERIOR ELEVATIONS
AND FINISH MATERIAL SCHEDULE FOR
REQUIRED FINISHES.
9. STOREFRONT DOORS AND FRAMES ARE
SCHEDULED AROUND KAWNEER PRODUCTS.
GENERAL HARDWARE NOTES
1. ALL HARDWARE SHALL BE FURNISHED AND
INSTALLED BY THE GENERAL CONTRACTOR
UNLESS NOTED OTHERWISE.
2. SEE OUTLINE SPECIFICATIONS FOR
REQUIRED FINISHES.
3. ALL LOCKS TO BE MASTER KEYED TO
SELECTED SYSTEM. COORDINATE WITH
OWNER FOR MASTER/SUB-MASTER KEYING.
4. ALL DOORS SHALL HAVE ADA APPROVED
TYPE HARDWARE (VERIFY IN FIELD).
5. PROVIDE FRAME SILENCERS AND DOOR
STOPS FOR ALL DOORS. STOPS MAY BE
FLOOR MOUNTED OR WALL MOUNTED.
6. PROVIDE 1 1/2 PAIR HINGES PER LEAF UP TO
7'-0" TALL DOORS. PROVIDE 2 PAIR HINGES
PER LEAF FOR DOORS EXCEEDING 7'-0" TALL,
UNLESS NOTED OTHERWISE.
7. EXIT HARDWARE SHALL COMPLY WITH ALL
APPLICABLE CODES.
8. THE MAXIMUM DIMENSION FROM THE TOP OF
THE THRESHOLD TO THE EXTERIOR LANDING
AT EXTERIOR DOORS SHALL NOT EXCEED
1/2". (VERIFY IN FIELD).
9. ADJUST CLOSERS SUCH THAT SWEEP
PERIOD FROM AN OPEN POSITION OF 90
DEGREES, THE TIME REQUIRED TO MOVE
THE DOOR TO AN OPEN POSITION OF 12
DEGREES SHALL BE 5 SECONDS MINIMUM.
MAXIMUM OPENING FORCE OF DOORS SHALL
BE 5 LBF FOR INTERIOR DOORS, AND 15 LBF
FOR EXTERIOR DOORS.
10. HARDWARE PROVIDER TO REVIEW
HARDWARE SETS, DOOR LOCKING
ARRANGEMENTS, OVERALL FUNCTIONALITY
ASPECTS & KEYING WITH OWNER AND
GENERAL CONTRACTOR TO COMPLETE
HARDWARE ORDER. PROVIDE SAMPLES AS
REQUIRED.
ACCESSIBLE DOOR CLEARANCE NOTES
1. UNLESS SPECIFICALLY NOTED OR
DIMENSIONED OTHERWISE ALL NEW DOORS
SHALL BE LOCATED WITH THE DOOR
OPENING 4" FROM A PARTITION CORNER (I.E.
2" OF FRAMING AND A 2" DOOR FRAME).
2. ALL NEW AND SPECIFICALLY DESIGNATED
DOORS SHALL MAINTAIN CLEAR AREAS
BASED ON THE APPROACH DIRECTION AND
THEIR OPERATIONAL SIDE. REQUIRED CLEAR
AREAS MUST BE FREE OF "PROJECTIONS" AS
DESCRIBED BY THE GOVERNING ADA CODE
(THIS INCLUDES WALL MOUNTED
ACCESSORIES, PLUMBING FIXTURES,
ADJACENT PARTITIONS, CURBS, AND SIMILAR
SYSTEMS).
3. DIAGRAMS OF RELEVANT REQUIRED
CLEARANCES ARE PROVIDED ON THE ADA
REFERENCE PAGE IN THIS DRAWING SET.
THIS SET OF ICC.ANSI A117.1-2009
STANDARDS HAS BEEN INDICATED HERE FOR
GENERAL REFERENCE PURPOSES ONLY. IN
NO WAY DOES THIS SHEET REPRESENT ALL
APPLICABLE COMPONENTS OF THE
"ACCESSIBLE AND USABLE BUILDINGS AND
FACILITIES" NATIONAL STANDARD.
GENERAL PARTITION NOTES
1. INSTALL CONTINUOUS BLOCKING/FRAMING
AT ALL DROP FRAMED CEILING LEVEL(S) AS
REQUIRED.
2. INSTALL CONTINUOUS BLOCKING/FRAMING
AT MID-HEIGHT OF ALL STUD WALLS
GREATER THAN 10'-0" HIGH AS REQUIRED
BASED ON MANUFACTURER SPECIFICATIONS.
3. ALL PARTITIONS SHALL BE FINISHED PER
FINISH SCHEDULE.
4. ALL STUD WALLS NOT EXTENDED TO
UNDERSIDE OF ROOF DECK AND TALLER
THAN 8'-0" ABOVE FINISHED FLOOR SHALL BE
BRACED AT TOP AT ±6'-0" ON CENTER WITH
EITHER STUD "KICKERS" OR STUDS
EXTENDED UP TO ROOF STRUCTURE FOR
ANY WALL GREATER THAN 10'-0" IN LENGTH.
5. ALL GYPSUM WALL BOARD WALL
INTERSECTING EXTERIOR WALLS SHALL BE
GLUED TO END STUDS AND SEALED AT WALL
JOINT CONTINUOUS WITH ACOUSTICAL
SEALANT.
6. PRESSURE-TREATED BOTTOM PLATE
REQUIRED AT ALL WOOD FRAMED WALLS
RESTING ON SLAB-ON-GRADE OR CONCRETE
AND/OR MASONRY THAT IS IN DIRECT
CONTACT WITH GROUND.
7. INFORMATION ON THIS SCHEDULE IS TO BE
USED IN CONJUNCTION WITH FLOOR PLANS,
REFLECTED CEILING PLANS, INTERIOR
ELEVATIONS AND SECTIONS.
8. EXTERIOR ENVELOPE IS NOT SCHEDULED.
REFER TO SECTIONS AND DETAILS FOR
TYPICAL BUILDING EXTERIOR WALL
DESCRIPTION.
9. ALL SINGLE-LAYER GYPSUM BOARD WALLS
CONTINUOUS AND CONTIGUOUS WITH MULTI-
LAYER GYPSUM BOARD WALLS SHALL
MAINTAIN ONE CONTIGUOUS OUTER LAYER
OF GYPSUM BOARD AT THE SAME FACE OF
FINISH. STUDS AND FURRING CHANNELS
SHALL BE OFFSET ACCORDINGLY.
10. PARTITION TYPES ARE CONTINUOUS ACROSS
DOOR AND WINDOW OPENINGS AND AROUND
CORNERS UNLESS OTHERWISE NOTED.
GENERAL SOUND TRANSMISSION (STC) NOTES
1. ALL GYPSUM WALL BOARD CORNER JOINTS
SHALL BE SEALED.
2. WHERE SOUND TRANSMISSION CLASS (STC)
RATINGS ARE INDICATED, PROVIDE
MATERIALS AND INSTALLATION IDENTICAL IN
EVERY RESPECT TO MANUFACTURERS
TESTED SYSTEM OF INDICATED RATING.
3. FOR WALLS EXTENDING TO UNDERSIDE OF
STRUCTURE ABOVE, SOUND-RATED
INSULATION BLANKETS SHALL BE FULL
HEIGHT OF PARTITION. FOR WALLS
EXTENDING 6" ABOVE FINISH CEILING, LAY
SOUND-RATED BLANKETS 24" FROM EACH
SIDE OF PARTITION.
4. ELECTRICAL OUTLET BOXES IN OPPOSITE
FACES OF SOUND-RATED WALLS SHALL BE
SEPARATED HORIZONTALLY BY A MINIMUM
24". BACKS AND SIDES OF BOXES TO BE
SEALED WITH 1/8" RESILIENT SEALANT AND
BACKED WITH 2" MINERAL FIBER INSULATION.
5. APPROVED PERMANENT AND RESILIENT
ACOUSTICAL SEALANT SHALL BE PROVIDED
IN SOUND-RATED PARTITIONS ALONG THE
JOINT BETWEEN THE FLOOR AND ALL
SEPARATE WALLS.
GENERAL MOISTURE RESISTANT PARTITION
NOTES
1. PROVIDE MOISTURE RESISTANT GYPSUM
BOARD IN ALL WET OR DAMP SPACES.
2. MOISTURE RESISTANT GYPSUM BOARD
SHALL BE USED AT ALL GYPSUM WALLBOARD
PARTITIONS SCHEDULED TO RECEIVE
CERAMIC TILE, PARTITIONS IN KITCHEN
AREAS, AND AT ALL TOILET ROOM
PARTITIONS.
3. PROVIDE TILE BACKER BOARD IN LIEU OF
GYPSUM WALL BOARD BEHIND ALL WALL
TILE, SEE INTERIOR DETAILS FOR TILE
LOCATIONS.
GENERAL PARTITION DEFLECTION NOTES
1. ALL STUD WALLS EXTENDED TO UNDERSIDE
OF ROOF STRUCTURE (DECK OR JOISTS)
SHALL UTILIZE A DEFLECTION-TYPE TOP
CONNECTION WHICH ALLOWS ROOF
DEFLECTION.
2. LIMITING HEIGHTS OF GYPSUM BOARD
PARTITIONS ARE AS PUBLISHED FOR THE U.S.
GYPSUM BOARD PRODUCTS FOR MAXIMUM
L/240 DEFLECTION AT 5 PSF LATERAL LOAD.
VERIFY ACTUAL LIMITING HEIGHT FOR
APPROVED MANUFACTURER'S PRODUCTS.
WHERE SCHEDULED PARTITION EXCEEDS
LIMITING HEIGHT, INSTALLERS SHALL ADD
BRACING ELEMENTS (ABOVE CEILING), OR
DECREASE STUD SPACING, AND/OR GAUGE
AS REQUIRED TO MAINTAIN L/240
DEFLECTION CRITERIA.
3. INSTALLERS SHALL CONFIRM ALLOWABLE
DEFLECTIONS FOR FINISH MATERIALS
APPLIED TO STUD PARTITIONS. WHERE
ALLOWABLE DEFLECTION OF FINISH
MATERIALS IS LESS THAN DEFLECTION OF
SCHEDULED PARTITION, STUD SPACING
AND/OR GAUGE SHALL BE ADJUSTED TO
CONFORM TO FINISH MATERIAL DEFLECTION
REQUIREMENTS.
4. ALLOWABLE DEFLECTION FOR ALL
PARTITIONS SCHEDULED TO RECEIVE
CERAMIC TILE IS L/360 MAXIMUM.
GENERAL FIRE RATED PARTITION NOTES
1. REFER TO UL RATINGS FOR ADDITIONAL
NOTES AND/OR REQUIREMENTS.
2. ALL PIPES, DUCTS AND BUS DUCTS, WHICH
PENETRATE THE FLOOR CONSTRUCTION,
SHALL BE INSTALLED SO AS TO MAINTAIN
THE FIRE RESISTIVE RATING AND
STRUCTURAL INTEGRITY OF THE BUILDING.
WALL PRIORITY LEGEND
(HIGHEST PRIORITY)
1 - 2 HOUR FIRE AND SMOKE WALL
2 - 2 HOUR FIRE AND 2 HOUR SHAFT WALL
3 - 1 HOUR FIRE AND SMOKE WALL
4 - 1 HOUR FIRE WALL
5 - NON-RATED
(LOWEST PRIORITY)
HIGHER
PRIORITY
PARTITION
LOWER
PRIORITY
PARTITION
GENERAL FINISH NOTES
1. CONSULT WITH OWNER FOR ALL REQUIRED
FINISH COLORS/TEXTURES. OWNER SHALL
HAVE CHOICE OF COLOR FROM
MANUFACTURER. FULL RANGE OF COLORS
FOR ALL FINISHES SPECIFIED.
2. ALL CLOSETS AND AUXILIARY SPACES SHALL
HAVE SAME FLOOR AND WALL FINISHES AS
ROOMS THEY ARE LOCATED IN, UNLESS
NOTED OTHERWISE.
3. IN ROOMS NOTED IN SCHEDULE PROVIDE
BASE AROUND ROOM PERIMETER, UNLESS
NOTED OTHERWISE.
4. INTERIOR WALLS AND INTERIOR FACE OF
EXTERIOR WALLS SHALL BE PAINTED,
CONSISTING OF (1) COAT OF PRIMER AND (2)
COATS OF INTERIOR FINISH LATEX, UNLESS
OTHERWISE NOTED.
5. SUBSTITUTIONS FOR SPECIFIED PRODUCTS
SHALL BE EQUAL TO THOSE SPECIFIED IN
COMPOSITION, PHYSICAL PROPERTIES,
COLOR AND TEXTURE AND APPEARANCE,
AND ENVIRONMENTAL QUALITIES. ALL
SUBSTITUTIONS SHALL BE SUBMITTED TO
THE ARCHITECT AND/OR OWNER FOR
REVIEW AND APPROVAL PRIOR TO
CONSTRUCTION.
GENERAL ROOF NOTES
1. ALL ROOFING, UNDERLAYMENT, AND SIMILAR
MATERIALS SHALL MEET CURRENT
GOVERNING CODE. MATERIAL INSTALLATIONS
SHALL BE PER MANUFACTURER
INSTRUCTIONS.
2. PROVIDE "CRICKETS" AROUND ALL
MECHANICAL EQUIPMENT, AND SIMILAR
CONDITIONS AS REQUIRED TO PREVENT
FLOW STOPPAGE OR PONDING. GENERAL
CONTRACTOR SHALL COORDINATE WITH
ROOFING MANUFACTURER.
3. ALL DIMENSIONS SHOWN TO ROOF-TOP
EQUIPMENT ARE APPROXIMATE, MEASURED
TO BACK OF PARAPET. GENERAL
CONTRACTOR SHALL COORDINATE EXACT
DIMENSIONS REQUIRED WITH MECHANICAL
AND FRAMING CONTRACTORS.
4. PROVIDE AND INSTALL PROTECTION MATS
INDICATED AND FROM ALL ACCESS POINTS TO
AND AROUND ALL EQUIPMENT REQUIRING
SERVICING.
5. SLOPE MEMBRANE ROOF MINIMUM 2% TO
ROOF DRAINS OR SCUPPERS.
6. "SCUPPER" INDICATES SCUPPER IN EITHER
PARAPET WALL OR GRAVEL STOP. SEE PLANS
FOR LOCATIONS.
7. ARROWS ON THE ROOF PLAN INDICATE
WATER DRAINAGE DIRECTION.
8. ROOF DRAINS SHALL NOT BE LOCATED LESS
THAN 12" FROM ANY BEAM OR JOIST
CENTERLINE.
GENERAL ROOF PENETRATION NOTES
1. GENERAL CONTRACTOR SHALL VERIFY
LOCATIONS OF ALL ROOF PENETRATIONS
WITH ELECTRICAL, MECHANICAL AND
PLUMBING DRAWINGS, INCLUDING ROOF-
MOUNTED EQUIPMENT, EXHAUST FANS, VENT
PIPES, LIGHTNING PROTECTION AND SIMILAR
SYSTEMS PRIOR TO CONSTRUCTION. REPORT
ANY INCONSISTENCIES IMMEDIATELY TO THE
ARCHITECT.
2. PROVIDE INSULATED ROOF BOOTS AND
CURBS.
3. ALL PLUMBING VENTS SHALL BE HELD A
MINIMUM OF 10'-0" FROM ANY AIR INTAKE.
4. PLUMBING PENETRATIONS NOT SHOWN.
5. ALL NEW ROOF PENETRATIONS SHALL BE
PERFORMED BY A QUALIFIED ROOFING
CONTRACTOR. ALL WORK SHALL BE IN FULL
COMPLIANCE ROOF MANUFACTURERS
STANDARD DETAILS, SPECIFICATIONS AND
RECOMMENDATIONS, SUCH THAT ALL
WARRANTIES REMAIN IN FULL EFFECT.
6. ALL EXPOSED MECHANICAL EQUIPMENT SHALL
BE PAINTED TO MATCH THE ARCHITECT'S
SELECTION
GENERAL ROOF FLASHING NOTES
1. ALL METAL FLASHING WORK SHALL CONFORM
TO LATEST EDITION OF "SHEET METAL & AIR
CONDITIONING CONTRACTORS’ NATIONAL
ASSOCIATION" (SMACNA) STANDARD DETAILS.
2. INSTALL CONTINUOUS ICE AND WATER
SHIELD/DAM; EXTEND FROM EAVE FACE TO AT
LEAST 24 INCHES INSIDE EXTERIOR WALL LINE
AND AT ALL RIDGES AND VALLEYS 36" WIDE.
ICE DAM AS MANUFACTURER BY "W.R. GRACE,
INC" OR EQUAL.
3. PROVIDE FLASHING AT ALL VALLEYS AND DRIP
EDGE AT ALL EAVES VIRGINIA CONSTRUCTION
CODE SECTION 1507.2.9. PROVIDE ALUMINUM
DRIP EDGE (2" X 1-1/2"X 0.032") AT ALL ROOF
EDGES.
4. ROOFING CONTRACTOR IS TO INSTALL
FLASHING AT ALL ROOF PENETRATIONS AS
PER MANUFACTURER'S STANDARD DETAILS.
5. ALL ROOF EDGE CONDITIONS ARE TO BE
CONSIDERED PARAPET WALLS UNLESS
OTHERWISE NOTED.
GENERAL ROOF INSULATION NOTES
1. INSULATION TO MEET MINIMUM R VALUES
INDICATED IN CODE SUMMARY, THICKNESS TO
BE AS REQUIRED. CRICKET SLOPE SHALL BE
TWICE ROOF SLOPE MINIMUM. PROVIDE TOP
LAYER PROTECTION MATERIAL PER
MANUFACTURERS RECOMMENDATIONS.
2. RIGID INSULATION BOARD CRICKETS
DIRECTING WATER TO ROOF DRAINS SHALL BE
SLOPED TO DIRECT POSITIVE DRAINAGE TO
THE ROOF DRAINS AT TWICE ROOF SLOPE
MINIMUM.
3. THICKNESS INDICATED ON THE ROOF PLAN IS
MINIMUM ALLOWED. THIS IS MEASURED FROM
THE TOP OF SUBSTRATE TO THE TOP OF
ROOF CONSTRUCTION PER THE ASSEMBLY
NOTED ON THE ROOF PLAN.
GENERAL REFLECTED CEILING PLAN NOTES
1. CEILING PLAN LAYOUTS SHALL BE
COORDINATED WITH MECHANICAL,
ELECTRICAL, AND OWNER'S REQUIREMENTS.
IN THE EVENT OF CONFLICT, MECHANICAL,
ELECTRICAL, PLUMBING OR FIRE
PROTECTION DRAWINGS WILL GOVERN FOR
THEIR SPECIFIC COMPONENT.
2. SEE ELECTRICAL DRAWINGS BY OTHERS FOR
ALL LIGHTING AND ELECTRICAL LAYOUTS
AND FIXTURE SPECIFICATIONS.
3. PROVIDE EXIT SIGNS AND/OR LIGHTS. SEE
LIFE SAFETY PLANS AND/OR ELECTRICAL
DRAWINGS FOR EMERGENCY EGRESS
LIGHTING.
4. GENERAL CONTRACTOR SHALL COORDINATE
WITH MECHANICAL, ELECTRICAL, AND
PLUMBING CONTRACTOR(S) FOR
SCHEDULING AND COORDINATION FOR
INSTALLATION OF ALL LIGHTING AND
ELECTRICAL COMPONENTS.
5. CEILING HEIGHTS SHOWN ARE
APPROXIMATE/ NOMINAL DIMENSIONS.
GENERAL CONTRACTOR SHALL VERIFY
EXACT HEIGHT IN FIELD.
6. GENERAL CONTRACTOR SHALL COORDINATE
ACCESS PANEL LOCATIONS AND SIZES
REQUIRED IN ANY HARD CEILINGS BASED ON
ANY MECHANICAL OR ELECTRICAL
EQUIPMENT LOCATED ABOVE "HARD"
CEILINGS.
7. REFER TO GENERAL FINISH NOTES AND
FINISH SCHEDULES FOR ADDITIONAL
INFORMATION.
8. OWNER PROVIDED SPEAKER SYSTEM NOT
SHOWN.
9. OWNER PROVIDED SECURITY SYSTEM NOT
SHOWN.
10. UNLESS OTHERWISE NOTED, GWB SHALL BE
FASTENED TO THE UNDERSIDE OF THE
FLOOR/ROOF STRUCTURE ABOVE AREAS
INDICATING A DROP ACT OR GWB CEILING.
SEE ARCHITECTURAL SECTIONS AND
DETAILS FOR ADDITIONAL INFORMATION.
11. PROVIDE 5/8" GYPSUM BOARD ABOVE ALL
DROP CEILINGS ASSEMBLIES UNLESS
OTHERWISE NOTED.
12. SOFFITS SHALL BE 1 INCH BELOW ADJACENT
LOWEST CEILING HEIGHT, UNLESS
OTHERWISE NOTED ON PLAN.
GENERAL FLOOR PLAN NOTES
1. REFER TO ADA ACCESSIBLE CLEARANCE
INFORMATION FOR DOORS, CASEWORK, SITE
WORK AND PLUMBING FIXTURES.
2. SEE WALL TYPES SCHEDULE FOR WALLS
THAT REQUIRE SOUND ATTENUATION
BLANKETS AND/OR SPECIFIC SOUND WALL
CONSTRUCTIONS.
3. SEE FINISH DRAWINGS AND/OR SCHEDULE
FOR SPECIFIC FINISH AND SURFACE
PREPARATION REQUIREMENTS.
4. SEE REFLECTED CEILING PLANS FOR
SPECIFIC CEILING TYPES, HEIGHTS, DETAILS,
LIGHTS, DIFFUSERS, AND SIMILAR
CONSTRUCTION.
5. SEE STRUCTURAL DRAWINGS FOR ANY
MISCELLANEOUS FRAMING MEMBERS THAT
ARE WITH WALL CONSTRUCTION ABOVE
FINISH CEILINGS, INDICATE REINFORCEMENT
REQUIREMENTS FOR CONCRETE BLOCK
WALLS, AND SIMILAR STRUCTURAL
ELEMENTS.
6. REFER TO PLUMBING DRAWINGS FOR FLOOR
DRAIN LOCATIONS. ENSURE CONCRETE SLAB
AND APPLIED FINISHES ARE SLOPED TO
DRAIN AS REQUIRED. ENSURE SMOOTH
TRANSITIONS.
7. FIRE EXTINGUISHERS (FE) SHALL BE
PROVIDED AND INSTALLED BY THE GENERAL
CONTRACTOR, SEMI-RECESSED CABINET
FULL PANEL, CLEAR ACRYLIC DOOR GLAZING,
STAINLESS STEEL WITH 1-1/2" SQUARE TRIM.
COORDINATE WITH LIFE SAFETY PLANS FOR
PROPOSED LOCATIONS.
8. PROVIDE BLOCKING FOR WALL MOUNTED
ACCESSORIES AND EQUIPMENT AS
REQUIRED.
9. PROVIDE 6" STUDS AT WATER CLOSET WET
WALLS UNLESS NOTED OTHERWISE.
10. FRAME ROUGH OPENING SIZE ACCORDINGLY
FOR DOORS/OPENINGS NOTED AS FUTURE
LIFE SAFETY GENERAL NOTES
1. ALL ROOMS WITH AN OCCUPANCY OF FIFTY
(50) OR GREATER REQUIRE A POSTED SIGN
OUTSIDE ALL DOORS OF THE ROOM STATING
THE MAXIMUM OCCUPANT LOAD OF THE
ROOM.
FIRE RATING GENERAL NOTES
1. ALL PIPES, DUCTS AND BUSS DUCTS, WHICH
PENETRATE THE WALLS, CEILINGS, OR
FLOOR CONSTRUCTION DESIGNATED AS FIRE
RATED ASSEMBLIES, SHALL BE INSTALLED SO
AS TO MAINTAIN THE FIRE RESISTIVE RATING
AND STRUCTURAL INTEGRITY OF THE
ASSEMBLY.
2. SEE ELECTRICAL DRAWINGS FOR ALL
EMERGENCY LIGHTING, EXIT SIGNAGE
LOCATIONS, AND SIMILAR ACCESSORIES.
3. SEE CODE ANALYSIS ON COVER SHEET FOR
MEANS OF EGRESS REQUIREMENTS.
4. DOORS SHALL SWING IN DIRECTION OF
EGRESS FOR SPACES OR AREAS WITH MORE
THAN 50 OCCUPANTS.
5. PROVIDE FLOOR IDENTIFICATION SIGNS IN
EXIT ENCLOSURES.
6. PROVIDE RAISED CHARACTER AND BRAILLE
EXIT SIGNS ADJACENT TO EACH DOOR TO AN
EXIT STAIRWAY, AN EXIT PASSAGEWAY AND
THE EXIT DISCHARGE.
FIRE ALARM PANEL GENERAL NOTES
1. GENERAL CONTRACTOR SHALL PROVIDE A
COMPLETE SHOP DRAWING OF THE FIRE
ALARM AND DETECTION SYSTEM (INCLUDING
THE MAIN PANEL) AND SUBMIT TO LOCALITY
FOR APPROVAL BEFORE CONSTRUCTION.
BID NOTES AND BID ALTERNATES
1. SEE SHEETS T2.01 AND T2.02 FOR PRODUCT SPECIFICATIONS FOR ANY
PRODUCT SPECIFICALLY SPECIFIED. PRODUCTS SPECIFIED ARE "BASIS
OF DESIGN" PRODUCTS THAT ESTABLISH THE LEVEL OF QUALITY AND
TYPE OF MATERIAL FOR THOSE PRODUCTS. ALTERNATE PRODUCTS
THAT MEET THE SAME LEVEL OF QUALITY AND SAME SPECIFICATIONS
WILL BE CONSIDERED, TO BE SUBMITTED TO ARCHITECT AND OWNER
FOR REVIEW PRIOR TO AWARD OF CONTRACT.
2. CONSTRUCTION ELEMENTS NOT SPECIFICALLY SPECIFIED WITH
PRODUCT SELECTIONS HAVE BEEN PROVIDED WITH PERFORMANCE
SPECIFICATIONS. ALL BUILDING PRODUCTS FOR THOSE ITEMS SHALL
MEET THE PERFORMANCE SPECIFICATIONS, TO BE VERIFIED BY
ARCHITECT AND/OR OWNER DURING SUBMITTAL/SHOP DRAWING
REVIEW.
3. THE FOLLOWING ITEMS SHALL USE THE FOLLOWING MATERIAL
ALLOWANCES FOR BIDDING IN LIEU OF PROVIDING MATERIAL
SPECIFICATIONS:
CARPET: $40.00 / SQUARE YARD
LVT/VCT: $30.00 / SQUARE YARD
VINYL COVE BASE: $4.00 / LINEAR FOOT
BRICK: $600.00 / 1,000
FOR ALL "ALLOWANCE" MATERIALS THE ALLOWANCE NOTED SHALL BE
UTILIZED FOR MATERIAL ONLY. INSTALLATION SHALLL BE INCLUDED IN
THE BASE BID. PLEASE NOTE: IF FINAL COST DURING CONSTRUCTION IS
LESS THAN THE BID UNIT PRICE, THE COST SAVINGS SHALL BE PASSED
ON TO THE OWNER VIA CHANGE ORDER.
4. UNIT PRICES FOR VARIOUS BUILDING/CONSTRUCTION ELEMENTS SHALL
BE PROVIDED WITH BIDS OR SUBMITTED PRIOR TO CONTRACT AWARD.
UNIT PRICES SHALL BE GIVEN FOR THE FOLLOWING ITEMS:
• FOOTING/FOUNDATION EXCAVATION ($ / LINEAR FOOT)
• CONCRETE SLAB-ON-GRADE REPAIR ($ / LINEAR FOOT)
• CONCRETE SIDEWALK AND BASE ($ / LINEAR FOOT)
• ROCK EXCAVATION ($ / LINEAR FOOT)
• WALL COPING ($ / LINEAR FOOT)
• HAULING ($ / TON / MILE)
• ROOF DECKING REPLACEMENT ($ / SQUARE FOOT)
• ROOF REPLACEMENT ($ / SQUARE FOOT)
5. THE FOLLOWING BID ALTERNATES ARE INCLUDED IN THESE DRAWINGS
AND SHALL BE BID AS ALTERNATE PRICES AND EITHER AN "ADD" OR
"DEDUCT" ON THE BID FORM. ANY ELEMENT NOT LISTED AS PART OF AN
ALTERNATE SHALL BE PART OF THE BASE BID.
ALTERNATE #1: NEW STEEL EXTERIOR CANOPY WITH CENTER VALLEY,
SEE ALTERNATE DETAILS ON SHEETS A3.03/S3.01.
ALTERNATE #2: ALTERNATE HVAC SYSTEM DESIGN FOR JURY ROOM
UTILIZING DUCTLESS MINI-SPLIT UNITS, SEE ALTERNATE DETAILS ON
SHEET M3.3 AND SPECIFICATION NOTES ON E2.1. (IN LIEU OF HVAC
SYSTEM SPECIFIED ON OTHER MECHANICAL SHEETS AS PART OF BASE
BID.)
ALTERNATE #3: NEW SIDEWALKS IN COURTYARD ON SHEETS C1 AND
A1.01 TO BE BID AS BRICK PAVERS TO MATCH EXISTING (IN LIEU OF
CONCRETE SIDEWALKS SHOWN WITH BASE BID.)
PROJECT NO
REVISIONS
SCALE
DATE
CHECKED BY
DESIGNED BY
DRAWN BY
Roanoke / Richmond Shenandoah Valley
New River Valley / Lynchburg
1208 Corporate Circle
Roanoke, VA 24018
540.772.9580 www.balzer.cc
12" = 1'-0"
J:
\2
2\
\0 3\
.0
S A
LE
M
C O
U R
T H
O U
S E
JU
R Y
R O
O M
E X
P A
N S
IO
N
\A R
C H
\D R
A W
IN
G
S \0
2.
S
A
LE
M C
O U
R T
H O
U S
E
J U
R Y
R O
O M
A
.r vt
9/ 8/
:3
1:
A M
T1.02 03220052.00
08/30/2023
S A
L E
M C
O U
R T
H O
U S
E
G E
N E
R A
L N
O T
E S
B
ID
N
O T
E S
E
A S
T C
A
LH
O U
N S
T R
E E
T S
A
LE
M , V
IR
G
IN
IA
CJ/MFK
RWP
RWP
JU
R
Y R
O O
M E
X P
A N
S
IO
N
08/30/2023
O
W
ETIHCRA
M M
O C
Lic. No. 013210
N O
LA
E
HT
I
TC
I A
G R
I N
V F
ROBERT W. PILKINGTON
CONFERENCE
C175
JURY ROOM
C106
JUDICIAL CORRIDOR
C165
HALL
C109
STOR
C111
TOILET
C110
WAIT/SEC
C173
JUDGE
C174
CONF
C112
CIRCUIT COURT
C105
HOLDING
C117
TEMPORARY SECURITY MEASURES SCOPE OF WORK:
NOTE: ALL ITEMS NOTED TO BE PROVIDED BY CONTRACTOR UNLESS OTHERWISE NOTED
1. CONTRACTOR SHALL INSTALL A TEMPORARY PARTITION FROM TOP OF EXIST CMU WALL TO UNDERSIDE OF ROOF DECK, USING METAL STUDS WITH 1/2" PLYWOOD, SCREWED TO STUDS W/TAMPER-RESISTANT SCREWS.
2. CONTRACTOR SHALL INSTALL TEMPORARY LOCKING DOOR HARDWARE (LOCKED FROM WORK AREA EA SIDE) AND INSTALL TEMPORARY BARRIER ON COURTROOM SIDE OF DOOR USING METAL STUDS AND 1/2" PLYWOOD SHEATHING, SCREWED TO STUDS W/TAMPER-RESISTANT SCREWS.
3. CONTRACTOR SHALL INSTALL TEMPORARY PARTITION IN HALLWAY FROM FLOOR TO UNDERSIDE OF ROOF DECK, USING METAL STUDS WITH 1/2" PLYWOOD, SCREWED TO STUDS W/TAMPER-RESISTANT SCREWS.
4. EXISTING DOOR TO BE LOCKED BY OWNER (LOCKED ON CORRIDOR SIDE).
5 CONTRACTOR SHALL INSTALL A TEMPORARY PARTITION FROM TOP OF EXIST STUD WALL TO UNDERSIDE OF ROOF DECK, USING METAL STUDS WITH 1/2" PLYWOOD, SCREWED TO STUDS W/TAMPER-RESISTANT SCREWS.
PROJECT NO
REVISIONS
SCALE
DATE
CHECKED BY
DESIGNED BY
DRAWN BY
Roanoke / Richmond Shenandoah Valley
New River Valley / Lynchburg
1208 Corporate Circle
Roanoke, VA 24018
540.772.9580 www.balzer.cc
As indicated
J:
\2
2\
\0 3\
.0
S A
LE
M
C O
U R
T H
O U
S E
JU
R Y
R O
O M
E X
P A
N S
IO
N
\A R
C H
\D R
A W
IN
G
S \0
2.
S
A
LE
M C
O U
R T
H O
U S
E
J U
R Y
R O
O M
A
.r vt
9/ 8/
:3
1:
A M
T1.03 03220052.00
08/30/2023
S A
L E
M C
O U
R T
H O
U S
E
T E
M P
O R
A R
Y S
E C
U R
IT
Y
P
LA
N
E
A S
T C
A
LH
O U
N S
T R
E E
T S
A
LE
M , V
IR
G
IN
IA
CJ/MFK
RWP
RWP
JU
R
Y R
O O
M E
X P
A N
S
IO
N
08/30/2023
ACTUAL
NORTH
PLAN
NORTH
N
N
1/4" = 1'-0"T1.03
1 TEMPORARY SECURITY PLAN
NOT TO SCALE
KEY PLAN
O
W
ETIHCRA
M M
O C
Lic. No. 013210
N O
LA
E
HT
I
TC
I A
G R
I N
V F
DIVISION 02 - EXISTING CONDITIONS
1. REFER TO THE DEMOLITION PLANS AND GENERAL NOTES FOR ADDITIONAL NOTES.
DIVISION 03 - CONCRETE (SEE STRUCTURAL NOTES FOR ADDITIONAL INFORMATION)
1. INTERIOR SLABS SHALL HAVE VAPOR BARRIER TO BE ASTM E 1745, CLASS A, NOT LESS
THAN 15 MILS THICK. VAPOR BARRIER SHALL BE CONTINUOUS FROM OUTSIDE FACE OF
EXTERIOR WALLS. ALL PENETRATIONS AND SEAMS SHALL BE SEALED WITH MEMBRANE
MANUFACTURER APPROVED TAPE AND/OR SEALANT. CONTRACTOR SHALL INSPECT
WITH SPECIAL INSPECTOR (AS REQUIRED) IMMEDIATELY BEFORE CONCRETE
PLACEMENT TO ENSURE INTEGRITY OF MEMBRANE.
2. FLOOR SLABS TO BE DEPRESSED WHEN NECESSARY TO ACCOMMODATE FINISHED
FLOOR SYSTEM WITH NO CHANGE IN FINISHED FLOOR ELEVATION TO ADJACENT FLOOR
SYSTEMS. FLOOR MATERIALS MAY INCLUDE RECESSED FLOOR MATS, TILE, CARPET, OR
SIMILAR FINISHES.
DIVISION 03 - ARCHITECTURAL CAST STONE COPINGS
1. MATCH EXISTING PRECAST COPING. SUBMIT SAMPLE FOR APPROVAL.
2. COMPLY WITH CURRENT ASTM C1364.
3. PROVIDE THE FOLLOWING:
A. COMPRESSIVE STRENGTH OF 6,500 PSI MIN AT 28 DAYS PER ASTM C1194.
B. ASTM C1195: 6.0% MAX BY COLD WATER METHOD.
C. AIR CONTENT: ASTM C173 OR C231. FOR WET-CAST PRODUCT SHALL BE 4.0-8.0% .
4. MATERIALS: PORTLAND CEMENT - TYPE I OR TYPE III, WHITE OR GRAY, ASTM C150.
COARSE AGGREGATES - GRANITE, QUARTZ, OR LIMESTONE, ASTM C33, EXCEPT FOR
GRADATION. FINE AGGREGATES - MANUFACTURED OR NATURAL SANDS, ASTM C33,
EXCEPT FOR GRADATION. COLORS - INORGANIC IRON OXIDE PIGMENTS, ASTM C979
EXCEPT THAT CARBON BLACK PIGMENTS SHALL NOT BE USED.
5. ADMIXTURES: ASTM C260 FOR AIR-ENTRAINING ADMIXTURES. ASTM C494/C495M TYPE
A - G FOR WATER REDUCING, RETARDING, ACCELERATING, AND HIGH RANGE
ADMIXTURES.
6. REINFORCING: REINFORCING BARS, ASTM A615/A615M GRADE 40 OR 60 STEEL
GALVANIZED OR EPOXY COATED WHEN COVER IS LESS THAN 1.5 IN. WELDED WIRE
FABRIC ASTM A185 WHERE APPLICABLE FOR WET CAST UNITS. FIBER REINFORCEMENT
(OPTIONAL) ASTM C1116.
7. ALL ANCHORS, DOWELS, AND OTHER ANCHORING DEVICES AND SHIMS SHALL BE
STANDARD BUILDING STONE ANCHORS COMMERCIALLY AVAILABLE IN A NON-
CORROSIVE MATERIAL SUCH AS ZINC PLATED, GALVANIZED STEEL, BRASS, OR
STAINLESS STEEL TYPE 302 OR 304.
DIVISION 06 – WOOD, PLASTICS, AND COMPOSITES (SEE STRUCTURAL NOTES FOR
ADDITIONAL INFORMATION)
1. WOOD CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE AMERICAN
INSTITUTE OF TIMBER CONSTRUCTION AND THE NATIONAL FOREST PRODUCTS
ASSOCIATION (NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION).
2. CONTRACTOR TO PROVIDE WALL BLOCKING FOR ALL SHELVING, EQUIPMENT, GRAB
BARS, MOP HOLDERS, FIXTURES, AND SIMILAR ACCESSORIES FOR FIRM SUPPORT.
COORDINATE WITH ALL CONTRACTOR, OWNER AND EQUIPMENT SUPPLIER
REQUIREMENTS PRIOR TO ENCLOSING FRAMING.
3. WOOD TREATMENT: PRESSURE TREAT ALL SILLS AND PLATES AND ANY OTHER WOOD
IN CONTACT WITH MASONRY, CONCRETE OR GROUND, AND AS SHOWN ELSEWHERE
ON DRAWINGS. PRESSURE TREATMENT SHALL COMPLY WITH AWPB STANDARDS C2
AND LP-22.
4. FASTENERS FOR PRESERVATIVE TREATED WOOD SHALL BE HOT-DIPPED ZINC COATED
GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE, OR COPPER.
DIVISION 06 – LAMINATE PLASTICS
1. SURFACING SHALL BE HIGH-PRESSURE DECORATIVE LAMINATE. SHEET BACKING
PANELS SHALL BE OF SIMILAR MATERIAL AND THICKNESS, WITHOUT DECORATIVE
FINISH. CORE MATERIAL SHALL BE 3/4” THICK MEDIUM DENSITY PARTICLEBOARD;
MINIMUM WEIGHT 40 LBS PER CUBIC FOOT. COUNTERTOPS SHALL BE FABRICATED IN
SINGLE LENGTHS UP TO 12’-0”; COUNTERTOPS OVER 12’-0” LENGTH SHALL HAVE
HAIRLINE JOINTS. ALL EXPOSED EDGES TO BE SMOOTH, SHARP, CLEAN. PROVIDE
OPENINGS (I.E. SINKS, GROMMETS, EQUIPMENT, RESTROOM ACCESSORIES, AND
SIMILAR PENETRATIONS) IN COUNTERTOP AS REQUIRED FOR EQUIPMENT. CONSULT
WITH OWNER TO CONFIRM LOCATIONS.
2. COUNTERTOPS SHALL BE AWI CUSTOM GRADE MIN, POST-FORMED WITH COVED
INTEGRAL SPLASHBACK AND WATERFALL FRONT EDGE.
3. CABINET HDPL SHALL BE HORIZONTAL GRADE, 0.028" MIN THICKNESS. VERTICAL
APPLICATIONS SHALL BE VERTICAL GRADE, 0.020" MIN. THICKNESS.
4. SURFACE BURNING CHARACTERISTICS: 1. TEST STANDARDS: ASTM E 84, ASTM E 162,
ASTM E 662, IMO FTP CODE PART 2 AND PART 5, AND UL 723. 2. INTERIOR FINISH
CLASSIFICATION, FIRE-RATED LAMINATE: CLASS A ACCORDING TO NFPA 101. FLAME
SPREAD LESS THAN 25 AND SMOKE DEVELOPED LESS THAN 450.
5. SURFACES SUBJECT TO FOOD CONTACT: COMPLY WITH NSF STANDARD 35.
COLOR, PATTERN, AND FINISH: SELECTED FROM MANUFACTURER'S FULL RANGE OF
AVAILABLE SELECTIONS.
DIVISION 06 – CASEWORK
1. THE CASEWORK SUBCONTRACTOR/SHOP SHALL PROVIDE A COMPLETE SET OF
CASEWORK SHOP DRAWINGS TO THE GENERAL CONTRACTOR FOR USE AND
REFERENCE PERTAINING TO THE CONSTRUCTION OF THE PROJECT. THESE SHOP
DRAWINGS SHALL BE CONSIDERED AS AN INTEGRAL PART OF THE CONTRACT
DOCUMENTS FOR THE CONSTRUCTION OF THE PROJECT.
2. ALL CASEWORK ITEMS SHALL BE FURNISHED TO THE JOBSITE IN PREFINISHED
CONDITION (I.E. STAINED, SEALED, LAMINATED, AND SIMILAR FINISHES) UNLESS
SPECIFICALLY NOTED OTHERWISE.
3. PROVIDE SUBMITTALS FOR COLOR AND FINISH SAMPLES.
4. CABINETS ARE TO BE KCMA A161.1 CERTIFIED WITH FLUSH OVERLAY CONSTRUCTION
MEETING AMERICAN WOODWORKERS INSTITUTE (AWI) CUSTOM GRADE STANDARDS.
5. CABINETS TO HAVE HDPL ON EXPOSED EXTERIOR SURFACES, EXPOSED INTERIOR
SURFACES, AND SEMI-EXPOSED SURFACES.
6. HARDWARE SHALL CONFORM TO ANSI/BHMA STANDARDS, GRADE 2 REQUIREMENTS.
DRAWER SLIDES SHALL HAVE A MINIMUM LOAD CAPACITY OF 75 POUNDS.
7. HARDWARE SHALL BE WIRE PULLS UNLESS OTHERWISE NOTED.
8. HINGES SHALL BE CONCEALED EUROPEAN-SYTLE, SELF-CLOSING HINGES.
DIVISION 06 – FIRE TREATED LUMBER AND SHEATHING
1. FIRE-RETARDANT-TREATED FRAMING LUMBER AND SHEATHING (IF SHOWN) SHALL
BEAR LABELS STATING CERTIFICATION AND HAVE A FRAME SPREAD OF 25 OR LESS
(CLASS A) WHEN TESTED IN ACCORDANCE WITH ASTM E84 AND UNDERWRITERS
LABORATORIES, INC.
DIVISION 04 - MASONRY TYPES AND SELECTIONS
1. GENERAL CONTRACTOR SHALL BUILD A SAMPLE PANEL OF BRICK VENEER, SHOWING
FULL RANGE OF BRICK FINISHES, INCLUDING ALL COLORS, TEXTURES AND MORTAR
COLORS AND FLASHING MATERIALS, FOR APPROVAL BY OWNER AND/OR ARCHITECT
PRIOR TO CONSTRUCTION.
2. BRICK VENEER SHALL MATCH EXISTING AND BE APPROVED BY OWNER, GRADE SW,
TYPE FBS COMPLYING WITH ASTM C-216, NOMINAL SIZE 2-3/4" X 8" X 4" (9 VERTICAL
COURSES PER 24"). LAY WALLS IN RUNNING BOND UNLESS NOTED OTHERWISE.
MORTAR SHALL MATCH EXISTING. FILL ALL JOINTS COMPLETELY WITH MORTAR AND
FINISH JOINTS WITH A STEEL TOOLED "CONCAVE" JOINT.
3. MORTAR SHALL BE ASTM C270, TYPE M BELOW GRADE AND TYPE N ABOVE GRADE.
COMPLY WITH MANUFACTURER MIXING AND APPLICATION SPECIFICATIONS.
DIVISION 04 - MASONRY
(SEE STRUCTURAL NOTES FOR ADDITIONAL INFORMATION)
1. BUILD ALL MASONRY LEVEL, SQUARE, PLUMB AND TRUE, USING BATTS FOR CLOSURES
ONLY. MAINTAIN MINIMUM 1" CLEAR AIRSPACE BETWEEN FACE OF
SHEATHING/INSULATION AND BACK OF VENEER BRICK. VENEER MASONRY SHALL
EXTEND TYPICALLY A MINIMUM OF 6" BELOW FINISHED GRADE.
2. MORTAR CROSS CELLS TO CONTAIN GROUT IN REINFORCED CELLS ONLY. NO
SPILLAGE OF GROUT INTO NON-REINFORCED CELLS ALLOWED.
3. FLASHING AND WEEPS: WALL FLASHING SHALL BE "PERM-A-BARRIER" FLEXIBLE
FLASHING BY W.R. GRACE, OR EQUAL, 60MIL SELF-ADHESIVE RUBBERIZED ASPHALT
SHEET LAMINATED TO A CROSS LAMINATED POLYETHYLENE FILM AND 12OZ HEMMED
STAINLESS STEEL DRIP EDGE STOPPING 3/8" BEYOND FACE OF WALL. INSTALL
FLASHING ABOVE ALL WINDOW AND DOOR HEADS, BELOW SILLS, AT FLOOR SLAB, AT
INTERSECTIONS OF ROOFING AND VERTICAL WALLS AND AT OTHER INTERRUPTIONS
TO DOWNWARD FLOW OF MOISTURE. TURN UP AND SEAL ENDS OF FLASHING TO
PREVENT HORIZONTAL MIGRATION OF MOISTURE. PROVIDE OPEN HEAD WEEPS 24" ON
CENTER AT ALL FLASHING POINTS. TOP OF FLASHING SHALL TERMINATE BEHIND WALL
MOISTURE BARRIER.
4. COMPLETED MASONRY WORK TO BE BRUSHED AND WASHED WITH WARM CLEAN
WATER, AND FREE OF EXCESS MORTAR. CLEAN ALL OTHER WORK AFFECTED BY
MORTAR SPILLS AND WASHING. NO ACID ALLOWED.
5. PROVIDE VERTICAL CONTROL JOINTS AT 25' O.C. IN ALL MASONRY WALLS UNLESS
NOTED. SEAL JOINTS WITH NON-SAG SEALANT MATCHING MASONRY COLOR.
DIVISION 04 - MASONRY REINFORCING, ANCHORS AND LINTELS
(SEE STRUCTURAL NOTES)
DIVISION 07 - GUTTERS AND FLASHING
1. METAL FLASHING AND ROOF TRIM - STAINLESS STEEL FLASHING'S TO BE MINIMUM 24
GAUGE, ASTM A 167, SOFT ANNEALED, WITH NO. 2D FINISH @ INTERSECTIONS OF
ROOF & VERTICAL WALLS & OTHER INTERRUPTIONS TO THE DOWNWARD FLOW OF
MOISTURE. METAL FLASHING TO BE ATTACHED WITH SCREWS AND NEOPRENE
WASHERS.
2. GUTTERS AND DOWNSPOUTS SHALL BE FACTORY FINISHED METAL; 0.027 INCH THICK -
GUTTERS, 0.020 INCH THICK DOWNSPOUTS. COLOR AS INDICATED IN DRAWINGS.
3. ALL GUTTERS TO BE RECTANGULAR STYLE PRE-FINISHED SEAMLESS METAL WITH
OVERSIZED DOWNSPOUTS.
4. ROOF SCUPPERS AND OTHER STAINLESS STEEL FLASHING TO BE MINIMUM 24 GAGE,
ASTM A 167, SOFT ANNEALED, WITH NO. 2D FINISH. NON-SPECIFIC METAL FLASHING
SHALL BE 24 GAGE ALUMINUM, FACTORY FINISHED, COLOR TO MATCH SURROUNDING
CONSTRUCTION. ALL FLASHING TO HAVE WATERTIGHT SEAMS WITHOUT EXPOSED
FASTENERS, DETAILED PER SMACNA STANDARDS.
DIVISION 07 - ROOFING SYSTEMS (METAL)
1. STANDING SEAM METAL ROOFING SHALL BE MINIMUM 24 GAGE ZINC COATED SHEET
STEEL, ASTM A653/A653M, G90, 12" FACTORY FORMED WIDE PANS, 1-1/2" SEAM HEIGHT,
FACTORY PRIMED AND FINISHED WITH FLOROPOLYMER TWO-COAT ORGANIC FINISH
SYSTEM, COLOR AS SELECTED BY OWNER FROM MANUFACTURER'S FULL RANGE, 20
YEAR FINISH WARRANTY; "FIELD-LOK" SERIES BY ATLAS, OR EQUAL.
2. PANELS SHALL BE CONTINUOUS FROM RIDGE TO EAVE, AND MECHANICALLY JOINED BY
ROLLER MACHINE PER MANUFACTURERS WRITTEN SPECIFICATIONS. PANELS SHALL BE
MOUNTED WITH CONCEALED CLEATS 12" ON CENTER, TO ALLOW PANEL MOVEMENT,
WITH CONTINUOUS SEALANT BEAD IN SEAM AND DOUBLE FOLD. NO EXTERNAL
FASTENERS WILL BE PERMITTED.
3. UNDERLAYMENT SHALL BE TYPE II NO. 30 ASPHALT - SATURATED ORGANIC FELT, WITH
ROSIN SIZED, BUILDING PAPER SLIP SHEET. ROOF SYSTEM TO COMPLY WITH UL 580
FOR CLASS 115 WIND UPLIFT RESISTANCE.
4. PROVIDE SNOW GUARDS (COLOR TO MATCH ROOF) AT MANUFACTURER
RECOMMENDED SPACING.
5. NO PARTIAL PANEL SHALL BE LESS THAN 6" WIDE. ALL SCREWS SHALL EXTEND
THROUGH INSULATION AND INTO ROOF STRUCTURAL DECK BELOW, TO BE
DETERMINED BY STANDING SEAM ROOF MANUFACTURER AND STRUCTURAL ROOF
DECKING.
DIVISION 07 - ROOFING SYSTEMS (MEMBRANE)
1. RUBBER MEMBRANE ROOFING SYSTEM SHALL BE SURE SEAL EPDM ROOFING SYSTEM,
60 MIL, FULLY ADHERED, BY CARLISLE ROOFING SYSTEMS OR EQUAL, AND SHALL BE
INSTALLED PER MANUFACTURER'S STRICT INSTALLATION GUIDE SPECIFICATIONS.
2. MEMBRANE TO BE PLACED OVER RIGID INSULATION (CARLISLE HPH
POLYISOCYANURATE OR EQUAL, THICKNESS AS REQ. PER DRAWINGS) AND STAGGER
JOINTS. MECHANICALLY ATTACH INSULATION WITH #14 SCREWS AS REQUIRED BY
CODE. PROVIDE ALL REQUIRED ADHESIVES, SEALANTS, AND FASTENERS AS SHOWN IN
DRAWINGS, CONSULT MANUFACTURER'S SPECIFICATIONS FOR SEALANT TYPES
REQUIRED.
3. GENERAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO ARCHITECT FOR
APPROVAL PRIOR TO INSTALLATION. PROVIDE ALL REQUIRED BOOTS, CURBING, WALK-
PADS (TO AND AROUND ALL HATCHES, DOORS AND EQUIPMENT) AND INCIDENTAL
ACCESSORIES, INSTALLED PER ROOFING MEMBRANE MANUFACTURER'S GUIDELINES.
4. WARRANTY PERIOD: 20 YEARS, TO INCLUDE ALL FLASHING.
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
1. RIGID PERIMETER INSULATION SHALL BE ASTM C578, TYPE IV; COMPRESSIVE
STRENGTH: 25 LB. PER SQUARE INCH, MINIMUM (ASTM D1621); WATER ABSORPTION:
0.1% BY VOLUME, MAXIMUM (ASTM C272). FOAM BLOWING AGENT SHALL PROVIDE AT
LEAST 90% REDUCTION IN OZONE DEPLETION POTENTIAL AS COMPARED WITH
STANDARD CFC BLOWING AGENTS. AGED R-VALUE: 4.4 PER INCH @ 75°F - THICKNESS
AS INDICATED OR OF THICKNESS TO ACHIEVE NOTED R-VALUE.
2. FIBERGLASS BATT INSULATION FOR CONCEALED INSTALLATIONS: KRAFT-FACED
THERMAL BATT INSULATION COMPLYING WITH ASTM C665, TYPE II, CLASS C, WITH
MAXIMUM FLAME SPREAD OF 25 AND SMOKE-DEVELOPMENT OF 450 OR LESS.
3. FIBERGLASS BATT INSULATION FOR EXPOSED INSTALLATIONS (INCLUDING ANY
FACINGS): SHALL HAVE A FLAME SPREAD RATING PER CURRENT GOVERNING CODE.
INSULATION SHALL BE FSK (FOIL) OR PSK (POLY) FACED FIBERGLASS THERMAL BATT
INSULATION COMPLYING WITH THE FLAMESPREAD REQUIREMENTS LISTED ABOVE, OR
UNFACED HIGH DENSITY MINERAL FIBER, WITH STRAPPING AS REQUIRED BE HELD IN
PLACE.
4. EXTERIOR SEALANTS: SHALL BE NON-SAG, SILICONE TYPE. COLOR TO MATCH
ADJACENT EXTERIOR MATERIALS, OR EXTERIOR DOOR OR WINDOW FRAMES. SUBMIT
SAMPLES TO ARCHITECT FOR APPROVAL. NOTE THAT MORE THAN (1) SEALANT COLOR
WILL BE REQUIRED. VERIFY COLOR LOCATIONS WITH ARCHITECT PRIOR TO
INSTALLATION.
5. INCLUDE SILL PLATE INSULATION, CAULKING OF SILLS AND PLATES AND FOAM
INJECTIONS AT WINDOW AND DOOR SHIM SPACE.
6. PROVIDE 15MIL VAPOR BARRIER UNDER CONCRETE SLAB ON GRADE. SEAL ALL JOINTS
& PENETRATIONS.
7. PROVIDE 60 MIL BITUTHENE WATERPROOFING MEMBRANE WITH 1/2" PROTECTION
BOARD AT ALL BELOW GRADE, EXTERIOR WALLS. CONTINUE MEMBRANE AND
PROTECTION BOARD OVER TOP OF FOOTING. WHERE GRADE IS LESS THAN 8" BELOW
FINISH FLOOR, EXTEND MEMBRANE 12" UP BEHIND MOISTURE BARRIER.
8. MOISTURE BARRIER BASIS-OF-DESIGN SHALL BE DUPONT TYVEK FLUID APPLIED
WEATHER BARRIER, OR EQUAL. CONTINUOUS ON ALL WALL SURFACES, AND
INTEGRATED WITH EMBEDDED FLASHING COMPONENTS.
DIVISION 08 - OPENINGS
1. ALL NEW DOORS TO BE MINIMUM 3'-0" WIDE X 7'-10" TALL UNLESS OTHERWISE NOTED.
PROVIDE "LEVER STYLE" HANDLES. HARDWARE SHALL BE HEAVY DUTY COMMERCIAL
CUSTOM GRADE. ALL HINGES TO BE PERMANENTLY MOUNTED TO MINIMUM HEIGHT OF
38” A.F.F. THRESHOLDS TO COMPLY WITH ADA. ALL HARDWARE FINISHES SHALL BE
BRUSHED NICKEL UNLESS NOTED OTHERWISE.
2. ALL DOORS AND FRAMES NOTED SPECIFICALLY WITH FIRE RATING CHARACTERISTICS
SHALL BE INSTALLED AND MAINTAINED WITH CLEARLY IDENTIFIABLE LABELS WITH U.L.
INFORMATION. ALL LABELS SHALL REMAIN UNPAINTED OR TARNISHED.
3. GLAZING
A. NON-INSULATED: 1/4" THICK, ASTM 1036,…